POWERBOX PSE100A48

6 0 - 1 0 0
W AT T S
D C / D C
S I N G L E
EURO CASSETTE
PSE100 Series
O U T P U T
Features
•
•
•
•
•
•
Under voltage logic alarm.
Conformally coating, tropic.
Reverse input voltage protection.
High efficiency.
Fully encapsulated, meets IP30 standard.
Convectional cooled.
Specifications
GENERAL
INPUT
Voltage
Isolation
Reverse voltage protection
Cooling
See table
Input – Output: 2kVdc (Input code A, B)
Input – Output: 2.5kVac / 4kVdc (Input code C/ D)
Input – Case: 2kVdc (Input code A, B)
Input – Case: 2.5kVac / 4kVdc (Input – code C/ D)
Output – Case: 2kVdc
Optional features
Yes.
OUTPUT
Voltage
See table.
Current
See table.
Source regulation
0.2%.
Load regulation
0.2% (0-100% load)
Output ripple (100kHz)
10mV p-p (typical)
Voltage adjustment
90% - 110%.
Current limit protection
105%.
Under voltage logic alarm
90% of nominal output.
Soft start
Yes.
Start-up time
1s.
Hold-up time
2-10ms
Efficiency
80-88%
ENVIRONMENTAL
Convectional cooling.
-Overvoltage protection, option A. The output
voltage is limited to 15% nominal output voltage. A
thyristor short- circuit the output.
-Undervoltage alarm with relay, option B. The
logic alarm output is replaced with Relay with
selectable alarm logic NO or NC.
-Built in series diode, option C. A series diode
on the output, when output is connected in parallel
with other power supplies to achieve redundancy.
Output power might be derated.
-Remote sense, option S. The voltage sensing can
be put at the load to compensate for voltage drop.
This is standard feature on 5V output.
-Inrush current limit with NTC, option H. Only for C
-input code. Reduce the inrush current during the
start up. The input voltage range will be affected.
- 2.5kVac isolation input/case, option E1. On
A and B inputs. The emission level increase to level A.
- 2.5kVac isolation output/case, option E2. The
emission level will increase to level A.
-Train input, option T. Input voltage range
according to train Standard EN50155 and IEC 60751.
- Euro panel, option L 8TE for PSE 100, 10TE for 5V
output with extra cooler.
- Wall mounting panels, option N. Wall
mounting panel with connector holder The female
connector has to be chosen.
- H15 screw type female, H15-S
- H15 fast-on 6.3mm female, H15-T
- Din rail TS35 clips, option Q.
Operating temperature
-25°C to +70°C (100% load, O/P > 10V). -25°C to
+55°C (100% load, O/P < 10V).
Temperature coefficient
0.02% / °C.
STANDARDS
Storage temperature
-40°C to 85°C.
Safety
IEC60950-1: 2001
Conformal coating
Conformal coated to withstand non-condensing
tropical environment RH 95%
EMI standards
EN55011/EN55022 class B, IEC/EN61000-6-2,
C-Tick
AS/NZS CISPR11: 2002 Group1 Class A
EMC standards
EN61000-6-2, EN/IEC61000-4-4, EN61000-4-5
MECHANICAL
Mechanical dimensions
3U x 8TE x 167mm
Weight
0.85kg
Your dependable power partner – www.powerbox.com.au
411
EURO CASSETTE
PSE100 Series
6 0 - 1 0 0
W AT T S
S I N G L E
O U T P U T
Selection Table
MODEL
NUMBER
INPUT
OUTPUT
COOLING
POWER
PSE100A5
10-30V
5V
20A
Convection
60W
PSE100A13.2
10-30V
13.2V
7.6A
Convection
100W
PSE100A15
10-30V
15V
6.7A
Convection
100W
PSE100A24
10-30V
24V
4.2A
Convection
100W
PSE100A48
10-30V
48V
2.1A
Convection
100W
PSE100B5
20-72V
5V
20A
Convection
100W
PSE100B13.2
20-72V
13.2V
7.6A
Convection
60W
PSE100B15
20-72V
15V
6.7A
Convection
100W
PSE100B24
20-72V
24V
4.2A
Convection
100W
PSE100B48
20-72V
48V
2.1A
Convection
100W
PSE100C5
50-150V
5V
20A
Convection
60W
PSE100C13.2
50-150V
13.2V
7.6A
Convection
100W
PSE100C15
50-150V
15V
6.7A
Convection
100W
PSE100C24
50-150V
24V
4.2A
Convection
100W
PSE100C48
50-150V
48V
2.1A
Convection
100W
PSE100D5
90-270V
5V
20A
Convection
60W
PSE100D13.2
90-270V
13.2V
7.6A
Convection
100W
PSE100D15
90-270V
15V
6.7A
Convection
100W
PSE100D24
90-270V
24V
4.2A
Convection
100W
PSE100D48
90-270V
48V
2.1A
Convection
100W
Technical Illustrations
412
D C / D C