Bulletin PD-20881 11/04 30CPH03PbF UltraFast Rectifier Features • • • • • trr = 40ns IF(AV) = 30Amp VR = 300V Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175°C Operating Junction Temperature Lead-Free ("PbF" suffix) Description/ Applications International Rectifier's 300V series are the state of the art Ultrafast recovery rectifiers designed with optimized performance of forward voltage drop and Ultrafast recovery time. The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as freewheeling diodes in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. Absolute Maximum Ratings Parameters Max VRRM Repetitive Peak Reverse Voltage IF(AV) Average Rectified Forward Current Per Leg @ TC = 142°C Total Device 30 Non Repetitive Peak Surge Current Per Leg 140 IFSM Units 300 V 15 A @ TJ = 25°C TJ, TSTG Operating Junction and Storage Temperatures - 65 to 175 °C Case Styles 30CPH03PbF Base Common Cathode 2 1 Anode 1 TO247 www.irf.com 3 2 Anode 2 Common Cathode 1 30CPH03PbF Bulletin PD-20881 11/04 Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters Min Typ Max Units Test Conditions VBR, Vr Breakdown Voltage, Blocking Voltage 300 VF Forward Voltage - - V I R = 100µA - 1.05 1.25 V I F = 15A, TJ = 25°C - 0.85 1.00 V I F = 15A, TJ = 125°C - 0.05 40 µA V R = VR Rated IR Reverse Leakage Current - 12 400 µA TJ = 125°C, VR = VR Rated CT Junction Capacitance - 45 - pF V R = 300V LS Series Inductance - 8 - nH Measured lead to lead 5mm from package body Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) Parameters trr IRRM Qrr Min Typ Max Units Test Conditions Reverse Recovery Time - - 40 - 32 - TJ = 25°C 45 - TJ = 125°C IF = 15A TJ = 25°C diF /dt = -200A/µs VR = 200V Peak Recovery Current Reverse Recovery Charge - 2.4 - - 6.1 - - 38 - - 137 - ns A IF = 1.0A, diF/dt = 50A/µs, VR = 30V TJ = 125°C nC TJ = 25°C TJ = 125°C Thermal - Mechanical Characteristics Parameters Min Typ Max TJ Max. Junction Temperature Range - 65 - 175 TStg Max. Storage Temperature Range - 65 - 175 RthJC Thermal Resistance, Junction to Case Per Leg - 0.9 2.0 RthJA ! Thermal Resistance, Junction to Ambient Per Leg - - 40 RthCS" Thermal Resistance, Case to Heatsink - 0.4 - Wt Weight - 6.0 - g - 0.21 - (oz) 6.0 - 12 Kg-cm 5.0 - 10 lbf.in Mounting Torque Marking Device Units °C °C/W 30CPH03 ! Typical Socket Mount " Mounting Surface, Flat, Smooth and Greased 2 www.irf.com 30CPH03PbF Bulletin PD-20881 11/04 100 1000 Reverse Current - I R (µA) Tj = 175˚C 10 125˚C 1 100˚C 0.1 25˚C 0.01 0 Tj = 125˚C 10 150˚C 0.001 50 100 150 200 250 300 Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage Tj = 25˚C 1000 Junction Capacitance - C T (pF) Instantaneous Forward Current - I F (A) Tj = 175˚C 100 1 0.4 T = 25˚C J 100 10 0.6 0.8 1 1.2 1.4 0 1.6 Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics 50 100 150 200 250 300 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Thermal Impedance Z thJC (°C/W) 10 1 0.1 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 PDM t1 t2 Notes: Single Pulse (Thermal Resistance) 0.01 0.00001 0.0001 0.001 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.01 0.1 . . 1 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics www.irf.com 3 30CPH03PbF Bulletin PD-20881 11/04 22 Average Power Loss ( Watts ) Allowable Case Temperature (°C) 180 170 DC 160 150 140 Square wave (D = 0.50) Rated Vr applied 130 see note (3) 120 20 18 RMS Limit 16 14 12 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 10 8 6 4 DC 2 0 0 5 10 15 20 25 0 5 10 15 20 25 Average Forward Current - I F(AV) (A) Average Forward Current - I F(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics 100 1000 If = 30A, Tj = 25˚C If = 30A, Tj = 125˚C trr ( ns ) Qrr ( nC ) If = 30A, Tj = 125˚C 100 If = 30A, Tj = 25˚C 10 100 1000 di F /dt (A/µs ) Fig. 7 - Typical Reverse Recovery vs. di F /dt 10 100 1000 di F /dt (A/µs ) Fig. 8 - Typical Stored Charge vs. di F /dt (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR 4 www.irf.com 30CPH03PbF Bulletin PD-20881 11/04 Reverse Recovery Circuit VR = 200V 0.01 Ω L = 70µH D.U.T. di F /dt dif/dt ADJUST D IRFP250 G S Fig. 9 - Reverse Recovery Parameter Test Circuit 3 t rr IF tb ta 0 Q rr 2 I RRM 4 0.5 I RRM di(rec)M/dt 5 0.75 I RRM 1 /dt di fF/dt 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr Fig. 10 - Reverse Recovery Waveform and Definitions www.irf.com 5 30CPH03PbF Bulletin PD-20881 11/04 Outline Table 15.90 (0.626) 15.30 (0.602) 3.65 (0.144) DIA. 3.55 (0.139) 5.30 (0.209) 4.70 (0.185) 5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) Base Common Cathode 5.50 (0.217) 1 2 3 2 4.50 (0.177) (2 PLCS.) 14.80 (0.583) 14.20 (0.559) 1 Anode 4.30 (0.170) 1 1.00 (0.039) 5.47 (0.216) Anode 2 Common Cathode 3.70 (0.145) 1.40 (0.056) 3 2 2.20 (0.087) MAX. 0.86 (0.034) 3.20 (0.126) MAX. 0.38 (0.015) 5.43 (0.213) Conform to JEDEC outline TO-247AC (TO-3P) Dimensions in millimeters and (inches) Marking Information EXAMPLE: THIS IS A 30CPH03 WITH ASSEMBLY LOT CODE 5657 ASSEMBLED ON WW 35, 2001 IN ASSEMBLY LINE "H" 6 INTERNATIONAL RECTIFIER LOGO PART NUMBER 30CPH03 P135H 56 ASSEMBLY LOT CODE 57 DATE CODE P = LEAD-FREE YEAR 1 = 2001 WEEK 35 LINE H www.irf.com 30CPH03PbF Bulletin PD-20881 11/04 Ordering Information Table Device Code 30 C P H 1 2 3 4 03 PbF 5 1 - Current Rating (30 = 30A) 2 - Circuit Configuration 6 C = Common Cathode 3 - Package 4 - Hyperfast Recovery 5 - Voltage Rating (03 = 300V) 6 - $ none = Standard Production P = TO-247 $ PbF = Lead-Free Tube Standard Pack Quantity : 25 pieces Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 11/04 www.irf.com 7