Catalog 1308242 Issued 3-03 (PDF Rev. 1-06) PRODUCTS UNLIMITED Model 93 - 3100 series Definite Purpose Contactor 3-pole, 50-60 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features Environmental Data • 3-pole contactors. • Convenient “universal” mounting plate. • Optional interlock/auxiliary switches available. Temperature Range: Storage and Operating: -40°C – +65°C. Flammability: UL 94-HB housing. Mechanical Data Contact Termination: Type: Box Lug with dual 0.250” (6.35 mm) quick connects. Wire Size: 14-2 Cu/Al AWG Tightening Torque: 50 in.-lbs. Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard. A 0.250” quick connect and a #6-32 screw, optional. Arc Cover: Standard. Weight: 32 oz. (910 g) approximately Contact Data @ 25°C Arrangements: 3 Form X (3PST-NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Coil Data @ 25°C Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130°C). Duty Cycle: Continuous. Contact Ratings Full Load Amps Number of Poles Line Voltage Locked Rotor Amps Resistive Amps Tungsten/ Ballast Amps 50 3 240 480 600 300 250 200 65 65 65 – 53 – 60 3 240 480 600 360 300 240 75 75 75 – 53 – Voltage Maximum Horsepower Single Phase Three Phase 110/120 200/208 240/277 480 600 110/120 200/208 240/277 480 600 3 7.5 10 5 7.5 10 - 15 15 25 25 25 25 30 30 Coil Data Nominal Coil Voltage Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush VA @ 50 Hz Nominal Inrush VA @ 60 Hz Nominal Sealed VA @ 50 Hz Nominal Sealed VA @ 60 Hz Nominal DC Resistance - Ohms Dimensions are shown for 834 reference purposes only. 24 182 6 -15 140 132 20 14 2.4 Dimensions are in inches over (millimeters) unless otherwise specified. 120 93 20 - 70 140 132 20 14 45 208/240 177 40 - 135 140 132 20 14 180 Specifications and availability subject to change. 277 235 50-180 140 132 20 14 280 480 374 120 - 286 140 132 20 14 852 www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 1-06) PRODUCTS UNLIMITED Ordering Information Typical Part No. B 3100 - 30 I 16 999 1. Series: 3100 = 3-pole, 50-60 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 30 = 3 Form X (3PST-NO-DM) 4.Coil Voltage (50/60 Hz.): I = 24VAC, molded K = 208/240VAC, molded J = 120VAC, molded M = 277VAC, molded W = 480VAC, molded 5.Contact Ratings (Inductive): 16 = 50 FLA 17 = 60 FLA 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7. Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options. Standard part numbers listed below are more likely to be available from stock. None at present. Termination Outline Dimensions 3.563 (90.5) 3.10 (78.7) 2.75 (69.9) .218 TYP. (5.537) .438 (11.12) 2.032 (51.61) .250 (6.35) .253 (6.43) 3.25 (82.55) 3.75 (95.25) 2.65 (67.3) 3.19 (81.03) 1.468 (37.29) 2.242 (56.95) Standard on 50-60 FLA Lug accepts 14-2 Cu/Al AWG .250 (6.35) Shown with Optional Auxiliary Switch Various interlock / auxiliary switches are available for the Model 93 contactor. Equipped with 0.250” (6.35) Quick Connect Terminals Factory Modifications Contact Config. NO NC Single unit interlock 1 0 configurations listed. 0 1 Maximum of two. Must 1 1 be same polarity. 2 0 See footnote (1) for ratings. 0 2 2 2 SPDT Circuit 1 1 See footnote (2) for ratings. 2 2 SPDT Dry Circuit, 0.1 amp max. 1 1 Gold Flashed Contacts 2 2 Description NORMALLY OPEN -303 STYLE NORMALLY OPEN & CLOSED -332 STYLE NORMALLY CLOSED -331 STYLE SPDT -337 & -341 STYLE Equipped with #6-32 Screw Terminals & Saddle Clamps Factory Modifications Field Added Kits Description Contact Config. Kit Catalog Number of NO NC Number Kits Required Single unit interlock 1 0 34300-342 1 configurations listed. 0 1 34300-343 1 Maximum of two. Must 1 1 34300-344 1 be same polarity. (note 1) Footnotes: Ratings of Auxiliary Interlocks / Switches (1) Contact Rating Single Circuit NO or NC (2) Contact Rating SPDT (337): and two circuit NO/NC: 10A, 1/3 HP, 125 or 250 VAC 1/2A, 125 VDC; 1/4A, 250 VDC: 120V 240V 480V 600V Break 3.0A 1.5A 0.75A 0.6A 4A 120 VAC on Lamp Load Make 30A 15A 7.5A 6A Continuous 10A 10A 10A 10A W/ #6-32 SCREW & SADDLE CLAMP -344 STYLE Dimensions are shown for reference purposes only. Field Added Kits Kit Catalog Number of Number Kits Required 34300-303 1 34300-331 1 34300-332 1 34300-303 2 34300-331 2 34300-332 2 34300-337 1 34300-337 2 34300-341 1 34300-340 1 Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 835