RECOM RP20

Features
●
●
●
●
●
●
●
●
4:1 Wide Input Voltage Range
20 Watts Output Power
1.6kVDC Isolation
UL 60950 Pending
Fixed Operating Frequency
Six-Sided Continuous Shield
Standard 50.8 x40.6x10.2mm Package
Efficiency to 84%
POWERLINE
DC/DC-Converter
RP20S_DEW
Series
20 Watt
Single & Dual
Output
Selection Guide 24V and 48V Input Types
Input (4)
Current
mA
Efficiency(5) Capacitive(6)
Load max.
%
µF
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
RP20-243.3SEW
9-36
3.3
4000
764
76
13000
RP20-2405SEW
9-36
5
4000
1111
79
6800
RP20-2412SEW
9-36
12
1670
1082
81
2200
RP20-2415SEW
9-36
15
1330
1082
81
755
RP20-483.3SEW
18-75
3.3
4000
377
77
13000
RP20-4805SEW
18-75
5
4000
548
80
6800
RP20-4812SEW
18-75
12
1670
541
81
2200
RP20-4815SEW
18-75
15
1330
541
81
755
RP20-2405DEW
9-36
±5
±2000
1111
79
±3400
RP20-2412DEW
9-36
±12
±833
1082
81
±680
RP20-2415DEW
9-36
±15
±666
1068
82
±450
RP20-4805DEW
18-75
±5
±2000
556
79
±3400
RP20-4812DEW
18-75
±12
±833
527
83
±680
RP20-4815DEW
18-75
±15
±666
521
84
±450
www.recom-international.com
July-2006
251
POWERLINE
DC/DC-Converter
Derating-Graph (Ambient Temperature)
125
RP20-2412SEW With Heat Sink
RP20-2412SEW
125
100
50
100
75
Natural Convection
Output Power (%)
Output Power (%)
75
25
0
-40 -25 -10 0
50 60 70 80 90 100
Ambient Temperature Range (°C) 56°C
25
0
-40 -25 -10 0
80 90 100
65°C
RP20-2412DEW With Heat Sink
125
100
100
75
Natural Convection
Output Power (%)
50
50 60 70
Ambient Temperature Range (°C)
RP20-2412DEW
Output Power (%)
Natural Convection
50
125
75
RP20-S_DEW
Series
25
0
-40 -25 -10 0
50 60 70 80 90 100
Ambient Temperature Range (°C) 64°C
50
Natural Convection
25
0
-40 -25 -10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
71°C
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at [email protected]
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
Input Filter
Input Surge Voltage (100 ms max.)
24V nominal input
48V nominal input
24V Input
48V Input
Input Reflected Ripple (nominal Vin and full load) (see Note 3)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see Note 7)
( Positive logic )
Remote OFF input current
Output Power
Output Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
Line Regulation (low line, high line at full load)
9-36VDC
18-75VDC
Pi Type
50VDC
100VDC
25mAp-p
DC-DC ON
DC-DC OFF
Nominal input
20ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
20mA
Single & Dual
Auxiliary
20W max.
±2%
±5%
Single (W)
Dual (W)
Auxiliary
Minimum Load (see Note 1)
±10%
±0.2%
±0.5%
±5%
10% of full load
continued on next page
252
July-2006
www.recom-international.com
RP20-S_DEW
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Line Regulation (low line, high line at full load)
Load Regulation (25% to 100% full load)
Cross Regulation (see Note 9)
Ripple and Noise (20MHz bandwith)
Single (W)
Dual (W)
Auxiliary
Single
Dual
Auxiliary
Dual
Auxiliary
Single
Dual
Auxiliary
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
±0.2%
±0.5%
±5%
±0.5%
±3%
±5%
±5%
±5%
75mVp-p
100mVp-p
1% of Vout
±0.02%/°C max.
3.3V
5V
12V
15V
500µs
3.9V
6.2V
15V
18V
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
1600VDC min.
Isolation Resistance
1 GΩ min.
Isolation Capacitance
300pF max.
Operating Frequency
300kHz typ.
Approved to Safety Standards
EN60950
Operating Temperature Range
-40°C to +85°C(with derating)
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
(see Note 8)
+100°C
Natural convection
Natural convection with Heat Sink
Thermal Shock
-55°C to +105°C
10°C/Watt
8.24°C/Watt
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel plated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions (see Note 10)
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Weight
48g
Dimensions
50.8 x 40.6 x 10.2mm
1928 x 103 hours
MTBF (see note 2)
www.recom-international.com
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
July-2006
253
RP20-S_DEW
Series
POWERLINE
DC/DC-Converter
Notes :
1. The RP20 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under
no-load condition will not damage these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control voltage is reference to negative input.
8. Heat sink is optional and P/N: 7G-0011A. Operation temperature range please see curve.
9. Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load
10.See application notes for EMI-filtering.
Package Style and Pinning (mm)
3rd angle
projection
50.10
40.60
10.20
5.6
dia.
1.0
Pin Connections
45.70
Pin #
1
2
4
5
6
7
8
5
17.80
Bottom View
5.10
15.20
1
10.20
12.70
6
Single
+Vin
-Vin
CTRL
No Pin
+Vout
-Vout
Trim
Dual
+Vin
-Vin
CTRL
+Vout
Com
-Vout
Trim
Pin Pitch Tolerance ±0.35 mm
2
7
4
10.20
17.80
8
External Output Trimming
Output can be externally trimmed by using the method
shown below.
( ) for dual output trim
7(7)
Trim Up
8(8)
RD
RU
8(8)
254
July-2006
Trim Down
6(5)