C O N V E N T I O N A L D E T E C T I O N Series Reversing Relay/ Synchronization Module Model RRS-MOD RRS-MOD Reversing relay/synchronization module for i3 series sounder models Product Overview Compatible with 2- and 4-wire i3 detectors equipped with a sounder System Sensor’s RRS-MOD reversing relay/synchronization module enhances the operation of 2- and 4- wire i3 series detectors equipped with a sounder. Activates all i3 sounders on a loop when one alarms Installation ease. The RRS-MOD includes a Velcro attachment for easy installa- i3 Synchronizes all sounders on the loop for a clear alarm signal Can be used with bell/alarm, alarm relay, or NAC outputs Includes a field-selectable switch to accommodate both coded and continuous alarm signals Allows i3 detector silencing from the panel or keypad Operates on 12- and 24-volt systems Quick-connect harness and color coded wires facilitate connections tion into the fire alarm control panel cabinet. A quick-connect harness and color-coded wires simplify connections. Intelligence. The RRS-MOD’s design is flexible to accommodate virtually any application. The RRS-MOD is compatible with both 2- and 4-wire i3 series detectors operating over 12V and 24V systems. The module can be used with either bell/alarm, alarm relay, or NAC outputs, and its field-selectable switch accommodates both coded and continuous alarm signals. Instant inspection. To meet fire alarm requirements, the RRS-MOD activates all i3 sounders on a loop when one alarms. Additionally, the RRS-MOD synchronizes the output of the i3 sounders, regardless of whether the panel’s alarm signal is continuous or coded, to ensure a clear alarm signal. Architect/Engineer Specifications Reversing relay/synchronization module shall be a System Sensor i3 Series model number RRS-MOD, listed to Underwriters Laboratories as a smoke detector accessory. The module shall allow all 2-wire and 4wire i3 Series detectors equipped with a sounder on a loop to sound when one alarms. The module shall provide a switch to toggle between coded mode and continuous mode. When in coded mode, the module shall synchronize the i3 sounders on the loop to mirror the input signal. When in continuous mode, the module shall synchronize the i3 sounders on the loop to the ANSI S3.41 temporal coded pattern. In either coded or continuous modes, the RRS-MOD module shall permit sounders to be silenced at the panel. The RRS-MOD module shall operate between 8.5 and 35 VDC, and shall provide 18 AWG stranded, tinned conductors connected to a quickconnect harness. Avg. Operating Current Relay Contact Rating 25mA 2 A @ 35 VDC Electrical Specifications Operating Voltage Nominal: 12 / 24 V Min.: Max.: 8.5 V 35 V Physical Specifications Operating Temperature Rangez Operating Humidity Range Wire Connections 32°F–131°F (0°C–55°C) 5% to 85% non-condensing 18 AWG stranded, tinned, 16″ long Dimensions Height: 2.5 inches (63 mm) Width: 2.5 inches (63 mm) Depth: 1 inch (25 mm) 2-Wire System Triggered from Alarm/Bell Circuit: UL LISTED ALARM CONTROL PANEL BELL/ ALARM CIRCUIT (positive signal in alarm state) PURPLE T+ EOL BROWN OUT+ 2–WIRE + INITIATING DEVICE – CIRCUIT YELLOW IN+ ORANGE IN– WHITE OUT– 1 + IN 1 + IN 2 + OUT 2 + OUT 3 - IN/OUT 3 - IN/OUT 4 RA+ 4 RA+ 5 RA- 5 RA- + + RED PWR+ – BLACK PWR– AUX POWER + – – OPTIONAL REMOTE ANNUNCIATOR (RA400Z) OPTIONAL REMOTE ANNUNCIATOR (RA400Z) S0101-00 2-Wire System Triggered from Alarm Relay Contact: UL LISTED ALARM CONTROL PANEL ALARM RELAY (NO Contact) NOTE: These diagrams represent two common wiring methods. Refer to the RRS-MOD installation manual for additional wiring configurations. PURPLE T+ EOL BROWN OUT+ 2–WIRE + INITIATING DEVICE – CIRCUIT YELLOW IN+ ORANGE IN– WHITE OUT– 1 + IN 1 + IN 2 + OUT 2 + OUT 3 - IN/OUT 3 - IN/OUT 4 RA+ 4 RA+ 5 RA- 5 RA- + + RED PWR+ – BLACK PWR– AUX POWER – OPTIONAL REMOTE ANNUNCIATOR (RA400Z) + – OPTIONAL REMOTE ANNUNCIATOR (RA400Z) S0103-00 Ordering Information Model Description RRS-MOD Reversing relay/synchronization module for i3 series smoke detectors System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 Documents-on-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor in China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor – Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor – Australia Ph: 613.54.281.142 Fx: 613.54.281.172 ©2002 System Sensor. The company reserves the right to change product specifications without notice. System Sensor – India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 A05-0350-000•11/02•#990