S-100F 100W Single Output Switching Power Supply series Features : AC input range selectable by switch Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 83KHz 2 years warranty (for 24V only) SPECIFICATION MODEL S-100F-5 S-100F-7.5 S-100F-12 S-100F-15 S-100F-24 DC VOLTAGE 5V 7.5V 12V 15V 24V 48V RATED CURRENT 20A 13.5A 8.5A 6.7A 4.5A 2.2A CURRENT RANGE 0 ~ 20A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 6.7A 0 ~ 4.5A 0 ~ 2.2A RATED POWER 100W 101W 102W 100.5W 108W 105.6W 125mVp-p 125mVp-p 125mVp-p 150mVp-p 150mVp-p 6.75 ~ 8.25V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT INPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 30ms at full load HOLD UP TIME (Typ.) 20ms at full load VOLTAGE RANGE 88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3.15A/115VAC 1.5A/230VAC COLD START 20A/115VAC 40A/230VAC (Note 4) OTHERS 81% <1mA / 240VAC OVERLOAD OVER VOLTAGE 5.75 ~ 6.75V 8.63 ~ 10.13V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. -10 ~ +60 83% 84% 27.6 ~ 32.4V 55.2 ~ 64.8V (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT VIBRATION 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE CSA60950-1 (for 24V only), UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 / 70% RH EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 314.9K hrs min. MIL-HDBK-217F (25 199*98*38mm (L*W*H) 0.65Kg; 20pcs/14.2Kg/0.8CUFT DIMENSION PACKING NOTE 80% 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY EMC 78% 248 ~ 370VDC LEAKAGE CURRENT PROTECTION SAFETY & 4.5 ~ 5.5V S-100F-48 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:S-100F-SPEC 2010-10-18 S-100F 100W Single Output Switching Power Supply Mechanical Specification Case No. 902 series Unit:mm 7 3.5 9 12 197 1 9.5 2 98 80 4 85.5 3 8.2 5 6 7 4- 3.5 M 3 57.5 4.5 120 199 190 Terminal Pin No. Assignment 3.5 Pin No. 1 2 3 38 3 28.5 3.5 3-M 18 18 9 9.5 6.5 Assignment AC/L AC/N FG Pin No. 4,5 6,7 Assignment DC OUTPUT -V DC OUTPUT +V 157 22 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P fosc : 83KHz 230 115 RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT FG PWM CONTROL O.L.P. Derating Curve +V -V O.V.P. Static Characteristics (24V) OUTPUT VOLTAGE (V) S-100F-12,24 100 80 S-100F-5,7.5 LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 350 28 300 24 250 20 200 16 150 12 100 8 50 80 160 85 170 90 180 95 190 100 200 105 210 110 220 115 230 120 240 125 250 OUTPUT RIPPLE (mVp-p) Ta=25 32 130 260 INPUT VOLTAGE (V) 60Hz File Name:S-100F-SPEC 2010-10-18