Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) CSM_S8VM_DS_E_7_1 Power Supply Featuring OMRON’s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing • New undervoltage alarm function assists in determining causes of errors (S8VM-@@@24A@/P@ only). • Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only). • Broad range of possibilities with 8 capacities and 29 models to choose from. • RoHS-compliant • New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W models). • Finger protection prevents electric shock. • DIN Rail mounting. • Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/No. 60950-1/No. 213, EN50178, EN60950-1 (The 300-, 600-, and 1,500-W models will not conform to safety standards if the customer replaces the fan.) • Conforms to SEMI F47-0200 (when 200-V input is used). • Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models). ! Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 32. Model Number Structure ■ Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2. S8VM- @@@@@@@ 1 1. Power Ratings 015: 15 W 030: 30 W 050: 50 W 100: 100 W 150: 150 W 300: 300 W 600: 600 W 152: 1,500 W 2. Output Voltage 05: 5 V 12: 12 V 15: 15 V 24: 24 V 2 3 4 3. Configuration/Functions None: Open-frame type Standard type C: Covered type Standard type A: Covered type Undervoltage alarm type (Sinking) (See note 2.) P: Covered type Undervoltage alarm type (Sourcing) (See note 2.) 4. Configuration None: Bottom mounting type (See note 3.) D: DIN Rail mounting bracket type Note: 1. A forced-air cooling method with a fan is used with 300-, 600-, and 1,500-W models. 2. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM10024A@/P@ and S8VM-15024A@/P@. 3. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail Mounting Bracket model or Mounting Brackets (sold separately). 1 S8VM Ordering Information ■ List of Models Note: For details on normal stock models, contact your nearest OMRON representative. Configuration Power ratings Open-frame 15 W type Input voltage 100 to 240 VAC 50 W 100 W 150 W 15 W 30 W 50 W 100 W 150 W 300 W (See note 4.) Note: 1. 2. 3. 4. 5. 6. Output current Standard model 30 W Covered type Output voltage 100 to 240 VAC 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 600 W (See note 4.) 5V 12 V 15 V 24 V 1,500 W (See note 4.) 24 V 3A 1.3 A 1A 0.65 A 6A 2.5 A 2A 1.3 A 10 A 4.3 A 3.5 A 2.2 A 20 A 8.5 A 7A 4.5 A 27 A S8VM-01505 S8VM-01512 S8VM-01515 S8VM-01524 S8VM-03005 S8VM-03012 S8VM-03015 S8VM-03024 S8VM-05005 S8VM-05012 S8VM-05015 S8VM-05024 S8VM-10005 S8VM-10012 S8VM-10015 S8VM-10024 S8VM-15005 (See note 2.) 12.5 A S8VM-15012 10 A S8VM-15015 6.5 A (See note 6.) S8VM-15024 3A S8VM-01505C 1.3 A S8VM-01512C 1A S8VM-01515C 0.65 A S8VM-01524C 6A S8VM-03005C 2.5 A S8VM-03012C 2A S8VM-03015C 1.3 A S8VM-03024C 10 A S8VM-05005C 4.3 A S8VM-05012C 3.5 A S8VM-05015C 2.2 A S8VM-05024C 20 A S8VM-10005C 8.5 A S8VM-10012C 7A S8VM-10015C 4.5 A S8VM-10024C 27 A S8VM-15005C (See note 2.) 12.5 A S8VM-15012C 10 A S8VM-15015C 6.5 A (See note 6.) S8VM-15024C 60 A S8VM-30005C 27 A S8VM-30012C 22 A S8VM-30015C 14 A S8VM-30024C Peak current: 16.5 A (200 VAC) 120 A S8VM-60005C 53 A S8VM-60012C 43 A S8VM-60015C 27 A S8VM-60024C Peak current: 31 A (200 VAC) 65 A (100 VAC) S8VM-15224C 70 A (200 VAC) (See note 3.) Peak current: 105 A (200 VAC) Bottom mounting Undervoltage alarm model Sinking Sourcing --------------------------------------------------------------------- DIN Rail mounting bracket Standard Undervoltage alarm model model Sinking Sourcing ----S8VM-15024A --------- ----S8VM-15024P --------- S8VM-01505D S8VM-01512D S8VM-01515D S8VM-01524D S8VM-03005D S8VM-03012D S8VM-03015D S8VM-03024D S8VM-05005D S8VM-05012D S8VM-05015D S8VM-05024D S8VM-10005D S8VM-10012D S8VM-10015D S8VM-10024D S8VM-15005D (See note 2.) S8VM-15012D S8VM-15015D S8VM-15024D S8VM-01505CD S8VM-01512CD S8VM-01515CD S8VM-01524CD S8VM-03005CD S8VM-03012CD S8VM-03015CD S8VM-03024CD S8VM-05005CD S8VM-05012CD S8VM-05015CD S8VM-05024CD S8VM-10005CD S8VM-10012CD S8VM-10015CD S8VM-10024CD S8VM-15005CD (See note 2.) S8VM-15012CD S8VM-15015CD S8VM-15024CD --------- --------- --------- --------- --------- --------- --- --- --- --- --- ------------------------S8VM-01524A (See note 1.) ------------S8VM-03024A (See note 1.) ------------S8VM-05024A S8VM-05024P ------------S8VM-10024A S8VM-10024P ----- ----------------------------------- ----------------------------------- ------------------------S8VM-01524AD (See note 1.) ------------S8VM-03024AD (See note 1.) ------------S8VM-05024AD S8VM-05024PD ------------S8VM-10024AD S8VM-10024PD --------S8VM-15024AD --------- ----S8VM-15024PD --------- No outputs are built into these models. The output capacity of the S8VM-15005@@ is 135 W. M8 bolts and nuts for the output terminals are not included with the S8VM-15224C. The 300-, 600-, and 1,500-W models use a forced cooling method with built-in fans. To perform front mounting using the bottom mounting models, use the Mounting Brackets (S82Y-VM@@F, sold separately). The output current for UL1604 certification is 6.3 A. 2 S8VM Specifications ■ Ratings/Characteristics Item Efficiency Input Output Power rating 5-V models 12-V models 15-V models 24-V models Voltage (See note 1.) Frequency (See note 1.) Current 100-V input 200-V input Power factor 100-V input 200-V input Harmonic current emissions Leakage 100-V input current 200-V input Inrush current 100-V input (See note 2.) 200-V input Voltage adjustment range (See note 3.) Ripple Input variation influence Load variation influence (rated input voltage) Temperature variation influence Startup time (See note 2.) Hold time (See note 2.) Additional Overload protection (See note 2.) functions Overvoltage protection (See note 2.) Undervoltage alarm indication Undervoltage alarm output Other Series operation Parallel operation Remote sensing function Ambient operating temperature Storage temperature Ambient operating humidity Dielectric strength Insulation resistance Vibration resistance Shock resistance Output indicator EMI Conducted Emission Radiated Emission EMS Approved UL standards cUL cUR EN/TÜV SEMI Weight (See note 7.) 15 W 30 W 50 W 100 W 75% min. 75% min. 80% min. 81% min. 78% min. 79% min. 79% min. 81% min. 78% min. 79% min. 79% min. 81% min. 80% min. 81% min. 80% min. 82% min. 100 to 240 VAC (85 to 264 VAC) 50/60 Hz (47 to 63 Hz) 0.5 A max. 0.9 A max. 0.8 A max. 1.4 A max. 0.25 A max. 0.45 A max. 0.4 A max. 0.7 A max. --0.98 min. --0.94 min. --Conforms to EN 61000-3-2 0.4 mA max. (at rated output) 0.75 mA max. (at rated output) 17.5 A max. (for cold start at 25°C) 35 A max. (for cold start at 25°C) −20% to 20% (with V. ADJ) (S8VM-@@@24A@/P@: −10% to 20%) 3.2% (p-p) max. (5 V), 3.2% (p-p) max. (5 V), 1.5% (p-p) max. (12 V), 1.5% (p-p) max. (12 V), 1.2% (p-p) max. (15 V), 1.2% (p-p) max. (15 V), 1.0% (p-p) max. (24 V), 0.75% (p-p) max. (24 V), (at rated input/output voltage) (at rated input/output voltage) 0.4% max. (at 85 to 264 VAC input, 100%) 0.8% max. (with rated input, 0 to 100% load) 150 W 81% min. 81% min. 81% min. 83% min. 2.0 A max. 1.0 A max. 0.02%/°C max. 1,100 ms max. (at rated input/output voltage) 800 ms max. (at rated input/output voltage) 20 ms typ. (15 ms min.) (at rated input/output voltage) 105% to 160% of rated load current, voltage 105% to 160% of rated load current, drop, intermittent, automatic reset voltage drop (12 V, 15 V, and 24 V), voltage drop, intermittent (5 V), automatic reset Yes (See note 4.) Yes (color: Yellow (DC LOW1), red (DC LOW2)) (S8VM-@@@24A@/P@ only) No Yes (S8VM-@@@24A@/P@ only) (Transistor output), 30 VDC max., 50 mA max. (See note 8.) Yes No No Yes Refer to the derating curve in Engineering Data (15-W, 30-W, 50-W, 100-W, 150-W Models). (with no icing or condensation) (See note 2.) −25 to 65°C 30% to 85% (Storage humidity: 25% to 90%) 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE/FG terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and PE/FG terminals; detection current: 100 mA) 500 VAC for 1 min. (between all outputs (except the detection output terminals) and detection output terminals; detection current: 20 mA) (S8VM-@@@24A@/P@ only) 100 MΩ min. (between all outputs and all inputs, PE/FG terminals) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Yes (color: Green) Conforms to EN61204-3 EN55011 Class B and based on FCC Class B (See note 5.) Conforms to EN61204-3 EN55011 Class B (See note 6.) Conforms to EN61204-3 High severity levels UL508 (Listing), UL60950-1, UL1604 (Listing; Class I/Division 2, Group A, B, C, D Hazardous Locations) (See note 9.) CSA C22.2 No.14, No. 213 (Class I/Division 2, Group A, B, D, D Hazardous Locations) CSA No. 60950-1 EN50178, EN60950-1 SELV (EN60950-1) According to VDE0160/P100 SEMI F47-0200 (200 VAC input) 180 g max. 220 g max. 290 g max. 460 g max. 530 g max. Note: 1. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. 2. Refer to Engineering Data (15-W, 30-W, 50-W, 100-W, 150-W Models) on page 9 to 11 for details. 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. 5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 15-W models, insert a clamp filter (ZCAT2436-1330 by TDK: 50 Ω min. [50 to 500 MHz], or the equivalent) in the output wire to reduce noise. 6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 150-W models, insert a clamp filter (ZCAT2017-0930 by TDK: 35 Ω min. [50 to 500 MHz], or the equivalent) in the input wire to reduce noise. 7. The weight indicated is for bottom mounting, open-frame models. 8. A@: Sinking type (NPN) P@: Sourcing type (PNP) 9. With the S8VM-15024@@, the output current for UL1604 certification is 6.3 A. 3 S8VM Item Efficiency Input Power rating 5-V models 12-V models 15-V models 24-V models Voltage (See note 1.) Frequency (See note 1.) Current 100-V input 200-V input Power factor Output Additional functions Other 100-V input 200-V input Harmonic current emissions Leakage current 100-V input 200-V input Inrush current 100-V input (See note 2.) 200-V input Voltage adjustment range (See note 3.) Ripple Input variation influence Load variation influence (rated input voltage) Temperature variation influence Startup time (See note 2.) Hold time (See note 2.) Overload protection (See note 2.) Overvoltage protection (See note 2.) Overheat protection (See note 2.) Undervoltage alarm indication Undervoltage alarm output Power failure alarm indication Power failure alarm output Series operation Parallel operation Remote sensing function Remote control function Ambient operating temperature Storage temperature Ambient operating humidity Dielectric strength Insulation resistance Vibration resistance Shock resistance Output indicator EMI Conducted Emission Radiated Emission EMS Approved standards (See note 8.) UL cUR cUR EN/TÜV SEMI Weight 300 W 600 W 1,500 W 77% min. 77% min. --78% min. 79% min. --79% min. 80% min. --81% min. 81% min. 82% min. 100 to 240 VAC (85 to 264 VAC) 100 to 240 VAC (85 to 265 VAC) 50/60 Hz (47 to 63 Hz) 4.0 A max. (5 V) 8.0 A max. (5 V) 20.0 A max. 4.3 A max. (12 V, 15 V, and 24 V) 8.3 A max. (12 V, 15 V, and 24 V) 2.0 A max. (5 V) 4.0 A max. (5 V) 11.0 A max. 2.2 A max. (12 V, 15 V, and 24 V) 4.2 A max. (12 V, 15 V, and 24 V) 0.98 min. 0.97 min. 0.94 min. 0.93 min. Conforms to EN61000-3-2 0.4 mA max. 1.5 mA max. 0.75 mA max. 1.5 mA max. 20 A max. (for cold start at 25°C) 40 A max. (for cold start at 25°C) −20% to 20% (with V. ADJ) 3.8% (p-p) max. (5 V), 2.0% (p-p) max. (12 V), 2.0% (p-p) max. (15 V), 1.25% (p-p) max. (See note 7.), 1.25% (p-p) max. (24 V), (at rated input/output voltage) (at rated input/output voltage) 0.4% max. (at 85 to 264 VAC input, 100%) 0.6% max. (with rated input, 0 to 100% load) 0.02%/°C max. 1,000 ms max. (at rated input/output voltage) 20 ms typ. (15 ms min.) (at rated input/output voltage) 105% to 160% of rated load current (5 V, 12 V, and 15 V), 120% to 160% of rated 105% to 160% of rated load current (100 VAC), load current (S8VM-30024C), 115% to 160% of rated load current (S8VM155% to 200% of rated load current (200 VAC), 60024C), voltage drop (12 V, 15 V, and 24 V), voltage drop, intermittent (5 V), au- voltage drop, automatic reset (Turns OFF tomatic reset when continuous for 5 s min.) (See note 4.) Yes (See note 4.) Yes (See note 4.) No No Yes (color: Red) Yes (Transistor output), 30 VDC max., 50 mA max. Yes Yes (Up to 2 units) Yes Yes Refer to the derating curve in Engineering Data (300-W, 600-W, 1,500-W Models). (with no icing or condensation) (See note 2.) −25 to 65°C 30% to 85% (Storage humidity: 25% to 90%) 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 3.0 kVAC for 1 min. (between all inputs and 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 outputs; detection current: 20 mA) mA) 2.0 kVAC for 1 min. (between all inputs and FG 500 VAC for 1 min. (between all outputs and PE terminals; detection current: 100 terminals; detection current: 20 mA) mA) 500 VAC for 1 min. (between all outputs and 100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 FG terminals; detection current: 300 mA) mA) 100 VAC for 1 min. (between all outputs and 500 VAC for 1 min. (between all outputs and PF terminals; detection current: 20 RC terminals; detection current: 100 mA) mA) 500 VAC for 1 min. (between all outputs and PF terminals; detection current: 20 mA) 100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC 100 MΩ min. (between all outputs and all inputs, FG terminals) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions 10 to 55 Hz, 0.15-mm single amplitude for 2 hours each in X, Y, and Z directions 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Yes (color: Green) Conforms to EN61204-3 EN55011 Class B and based on FCC Class B (See note 5.) Conforms to EN61204-3 EN55011 Class B (See note 5.) Conforms to EN61204-3 High severity levels UL508 (Recognition) (5 V, 12 V, and 15 V) UL508 (Listing) (24 V), UL60950-1 UL1604 (Listing; Class I/Division 2, Group A, B, C, D Hazardous Locations) (24 V) CSA C22.2 No.14, No. 213 (Class I/Division 2, Group A, B C, D Hazardous Locations) (24 V) CSA No. 60950-1 EN50178, EN60950-1 SELVE (EN60950-1) SEMI F47-0200 (200-VAC input) 1,100 g max. 1,700 g max. Conforms to EN61204-3 EN55011 Class A and based on FCC Class A (See note 6.) Conforms to EN61204-3 EN55011 Class A (See note 6.) UL508, UL60950-1 CSA C22.2 No.14, CSA No. 60950-1 EN50178, EN60950-1 SELVE (EN60950-1) 3,800 g max. Note: 1. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. 2. Refer to Engineering Data (300-W, 600-W, 1,500-W Models) on page 15 to 17 for details. 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. Alternatively, turn OFF the remote control signal and then turn it back ON again. 5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate is laid under the Power Supply. For 600-W models, insert a clamp filter (ZCAT3035-1330 by TDK: 100 Ω min. [50 to 500 MHz], or the equivalent) in the input wire, and ring core (HF60T38X14X22 by TDK: 16 Ω typ. [1 MHz], 46 Ω typ. [10 MHz], or the equivalent) in the output wire to reduce noise 6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class A when the aluminum plate is laid under the Power Supply (1,500-W models). 7. The measuring method conforms to JEITA standard RC-9131A. Refer to Ripple under Safety Precautions on page 32. 8. The Power Supply will not conform to safety standards if the customer replaces the fan. 4 S8VM Connections ■ Block Diagrams S8VM-015@@@@ (15 W) S8VM-01524A@ DC LOW1 DC LOW2 Undervoltage alarm indication Undervoltage detection +V AC (L) Fuse 2A INPUT Noise filter AC (N) DC OUTPUT Inrush Smoothing current protection circuit Rectification −V Rectifier/smoothing circuit Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler /FG S8VM-030@@@@ (30 W) S8VM-03024A@ Undervoltage DC LOW1 alarm indication DC LOW2 Undervoltage detection +V AC (L) Fuse 3.15 A INPUT Noise filter AC (N) DC OUTPUT Inrush Smoothing current protection circuit Rectification −V Rectifier/smoothing circuit Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler /FG S8VM-050@@@@ (50 W) S8VM-05024A@ (Sinking) S8VM-05024P@ (Sourcing) Undervoltage DC LOW1 alarm indication DC LOW2 Undervoltage DC LOW1 alarm indication DC LOW2 Alarm DC LOW1 Alarm DC LOW1 Undervoltage detection Alarm DC LOW2 Common Photocoupler AC (L) INPUT AC (N) Fuse 2A Undervoltage detection Alarm DC LOW2 Common Photocoupler +V Noise filter DC OUTPUT Rectification Harmonic current suppression Inrush Smoothcurrent ing protection circuit Rectifier/smoothing circuit −V Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit /FG Photocoupler 5 S8VM S8VM-100@@@@ (100 W) AC (L) Fuse 3.15 A INPUT S8VM-10024A@ (Sinking) S8VM-10024P@ (Sourcing) Undervoltage DC LOW1 alarm indication DC LOW2 Undervoltage DC LOW1 alarm indication DC LOW2 Inrush Harmonic current current protection Rectification suppression circuit Noise filter Undervoltage detection AC (N) Alarm DC LOW1 Alarm DC LOW1 Smoothing Undervoltage detection Alarm DC LOW2 Common Photocoupler Alarm DC LOW2 Common Photocoupler +V DC OUTPUT −V Drive Rectifier/smoothing circuit +S Remote sensing −S Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler /FG S8VM-150@@@@ (150 W) S8VM-15024A@ (Sinking) Inrush S8VM-15024P@ (Sourcing) Undervoltage DC LOW1 alarm indication DC LOW2 Undervoltage DC LOW1 alarm indication DC LOW2 Harmonic current current protection Rectification suppression circuit Fuse 5A INPUT Noise filter Undervoltage detection AC (N) Alarm DC LOW1 Alarm DC LOW1 AC (L) Smoothing Alarm DC LOW2 Common Undervoltage detection Photocoupler Alarm DC LOW2 Common Photocoupler +V DC OUTPUT −V Drive Rectifier/smoothing circuit +S Remote sensing −S Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler /FG S8VM-300@@C (300 W) Harmonic current Rectification suppression AC (L) Fuse 10 A INPUT Inrush current protection circuit Fan detection Power failure alarm indication PF Alarm PF-C PF-E Noise filter AC (N) Smoothing Power failure alarm detection Photocoupler +V DC OUTPUT −V Rectifier/smoothing circuit +V Drive Output voltage monitor −V Control circuit Overcurrent detection circuit +S Remote sensing Rectifier/smoothing circuit Voltage detection circuit Overheat detection circuit CB Power supply balance circuit Auxiliary power supply circuit Overvoltage detection circuit Fan Rectifier/smoothing circuit −S Current balance CBG +RC Remote control Photocoupler −RC 6 S8VM S8VM-600@@C (600 W) Harmonic current suppression AC (L) Fuse 15 A INPUT AC (N) Inrush current protection circuit Fan detection Power failure alarm indication PF Alarm PF-C PF-E Noise filter Rectification Power failure alarm detection Smoothing Photocoupler +V DC OUTPUT −V Rectifier/smoothing circuit Output voltage monitor −V Overcurrent detection circuit Control circuit Auxiliary power supply circuit +V Drive Rectifier/smoothing circuit +S Remote sensing Voltage detection circuit Overheat detection circuit −S CB Power supply balance circuit Overvoltage detection circuit Fan Current balance CBG +RC Remote control Rectifier/smoothing circuit S8VM-15224C (1,500 W) Inrush current protection circuit AC (L) Fuse 30 A INPUT −RC Photocoupler Harmonic current suppression Fan detection Power failure alarm indication Noise filter AC (N) Rectification Power failure alarm detection Smoothing Photocoupler PF Alarm PF-C PF-E +V DC OUTPUT Overcurrent detection circuit −V Rectifier/smoothing circuit Drive +V Output voltage monitor −V Control circuit +S Remote sensing Rectifier/smoothing circuit Auxiliary power supply circuit Voltage detection circuit Overheat detection circuit −S CB Power supply balance circuit Overvoltage detection circuit Fan Current balance CBG +RC Remote control Rectifier/smoothing circuit Photocoupler −RC /FG 7 S8VM Construction and Nomenclature (15-W, 30-W, 50-W, 100-W, 150-W Models) ■ Nomenclature No. Name 1 AC input terminals (L), (N) 15-W, 30-W, 50-W Models Open-frame Models Covered Models S8VM-015@@/S8VM-015@@D S8VM-030@@/S8VM-030@@D S8VM-050@@/S8VM-050@@D S8VM-015@@C@/S8VM-01524A@ S8VM-030@@C@/S8VM-03024A@ S8VM-050@@C@/S8VM-05024A@/P@ 2 8 9 10 5 4 3 7 6 2 1 3 PE terminal: Protective earthing terminal (S8VM-@@@@@C@/S8VM-@@@@@A@/ S8VM-@@@@@P@) FG terminal: Frame ground terminal (S8VM-@@@@@/S8VM-@@@@@D) DC output terminals (-V), (+V) 4 Output indicator (DC ON: Green) 5 6 Output voltage adjuster (V. ADJ) Undervoltage alarm indicator 1 (DC LOW1: Yellow) (See note 3.) 7 Undervoltage alarm indicator 2 (DC LOW2: Red) (See note 3.) 8 Undervoltage alarm output terminal 1: (DC LOW1) (See note 4.) 9 Undervoltage alarm output terminal 2: (DC LOW2) (See note 4.) 10 11 Common terminal for undervoltage alarm output (See note 4.) Remote sensing terminals (See note 5.) 12 Short bars (See note 5.) 100-W Models Open-frame Models Covered Models S8VM-100@@/S8VM-100@@D S8VM-100@@C@/S8VM-10024A@/P@ 6 7 5 4 11 12 3 12 12 11 2 1 10 9 8 Open-frame Models Covered Models S8VM-150@@/S8VM-150@@D S8VM-150@@C@/S8VM-15024A@/P@ Note: 1. The fuse is located on the (L) side. It is NOT user-replaceable. 2. If mounting is performed using a DIN Rail, the protective earthing connection is the panel mounting hole shown in the figure below. (A protective earthing connection stipulated in safety standards is used. Connect the ground completely (S8VM@@@@@D only)). Ground terminal: M3 (Depth: 8 mm max.)/Ground wire: AWG 18 Protective earthing connection 8 9 10 12 5 4 11 12 3 11 2 1 Connect the load lines to these terminals. Lights (green) while a direct current (DC) output is ON. Use to adjust the voltage. Lights only when a momentary drop in output voltage is detected. This status is maintained. Lights only when the output voltage drops to approximately 20 V or lower. Outputs only when a momentary drop in output voltage is detected. This status is maintained. (The transistor turns OFF when a voltage drop occurs.) Outputs only when the output voltage drops to approximately 20 V or lower. (The transistor turns OFF when a voltage drop occurs.) Common terminal (See note 6.) for terminals 8 and 9 Correct the voltage drop in the load lines. --- 12 150-W Models 12 Function Connect the input lines to these terminals. (See note 1.) Connect the ground line to this terminal. (See note 2.) 7 6 12 Ground 300-W, 600-W, 1,500-W Models Note: Refer to page 14. ■ Output Color Label 3. S8VM-@@@24A@/P@ only 4. S8VM-05024A@/P@, S8VM-10024A@/P@, S8VM15024A@/P@ only. Housing and terminals of the connector for undervoltage detection output are also provided. For details, refer to Undervoltage Alarm Output Connector Harness Manufacture Method on page 33 under Safety Precautions. 5. When not using the remote sensing function, leave the short bar in the same state as when shipped. 6. A@ models: Common terminal (emitter) P@ models: Common terminal (collector) This color label identifies the output voltage by color. Green: Blue: Yellow: White: 5V 12 V 15 V 24 V Color label identifying output voltage 8 S8VM Engineering Data (15-W, 30-W, 50-W, 100-W, 150-W Models) ■ Derating Curve 15W/30W Load ratio (%) Standard Mounting/Horizontal Mounting/Face-up Mounting 120 Open-frame type 100 A 80 Covered type 60 40 20 0 −20 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) 50W 120 Open-frame type 100 A Face-up Mounting Load ratio (%) Load ratio (%) Standard Mounting/Horizontal Mounting 120 Open-frame type 100 80 A 80 Covered type Covered type 60 60 40 40 20 20 0 −20 −10 0 10 20 30 40 50 60 0 −20 70 80 −10 0 10 20 Ambient temperature (°C) 30 40 50 60 70 80 Ambient temperature (°C) 100W Horizontal Mounting/Face-up Mounting 120 Open-frame type 100 A Load ratio (%) Load ratio (%) Standard Mounting 120 Open-frame type 100 80 A 80 Covered type Covered type 60 60 40 40 20 20 0 −20 −10 0 10 20 30 40 50 60 0 −20 70 80 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) Ambient temperature (°C) 150W Horizontal Mounting Open-frame type 100 A Face-up Mounting 120 Open-frame type 100 A 80 80 Covered type Load ratio (%) 120 Load ratio (%) Load ratio (%) Standard Mounting 120 Open-frame type 100 Covered type Covered type 60 60 40 40 40 20 20 20 0 −20 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) 0 −20 A 80 60 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) 0 −20 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) 300W/600W/1,500W Note: Refer to page 15. Note: 1. Internal parts may occasionally be deteriorated or damaged. Do not use the Power Supply in areas outside the derating curves (i.e., the area shown by shading A in the above graphs). 2. If there is a derating problem, use forced air-cooling. 3. When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them. Multiple 100- and 150-W models cannot be used side by side. Be sure to install the Power Supplies as far away from heat-generating sources as possible. As a reference value, allow at least 50 mm spacing on the right and left sides. If only 20 mm spacing is allowed, use the Power Supply at a load ratio of 80% or less. 4. When using 150-W models for a long period of time at an input voltage of 90 VAC or lower, reduce the load to 80% or less of the above derating curves. 9 S8VM ■ Mounting ■ Remote Sensing Function Standard Mounting (DIN Rail Mounting Bracket Models) Standard Mounting (Bottom Mounting Models) Correct (S8VM-100@@@@/150@@@@ only) This function compensates a voltage drop on the load lines. To use this function, connect after removing the two short bars of the remote sensing terminal. Correct Short bar V.ADJ *1 DC ON +S +V *1 −V Horizontal Mounting −S Correct *1 Face-up Mounting Face-up Mounting (DIN Rail Mounting Bracket Models) Incorrect Correct *2 Note: 1. Use a 2-conductor shielded cable as a connection wire (*1). 2. Use as thick a wire as possible since high voltage drops on the load lines (*2) may activate the overvoltage protection function. 3. Use when the voltage drop is 0.3 V or lower. 4. When the +S and −S terminals are opened with the short bar removed, the overvoltage protection function is activated and the output voltage will be cut off. 5. If the load line is too long, use an electrolytic capacitor in the following 3 locations: 1) Across the load terminals 2) Between the +S terminal and + terminal 3) Between the −S terminal and − terminal Select the capacity of the connected capacitor from between several tens to several hundreds of µF as a guide, and then determine the capacity when actually connecting the capacitor between terminals as shown below. + V.ADJ *1 DC ON +S + Face-down Mounting (DIN Rail Mounting Bracket Models) Face-down Mounting Incorrect Incorrect +V −V + −S ■ Inrush Current, Startup Time, Output Hold Time Input OFF Input ON AC input voltage Inrush current on input application Surface Mounting for Standard Mounting Direction Surface Mounting for Face-up Mounting Correct Correct AC input current 95% 90% Terminal block Output voltage Hold time Startup time ■ Reference Values Item Reliability (MTBF) The terminals are in front. The terminals are on the top. Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the Power Supply within the derating curve for the mounting direction that is used. 2. Use the metal plate as the mounting panel (*1). 3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by means of natural air flow. 4. Mounting screw tightening torque (recommended value: M3 (0.49 N·m)) Value Definition 135,000 hrs MTBF stands for Mean Time Between Failures, which min. is calculated according to the probability of accidental device failures, and indicates the reliability of a device. Therefore, it does not necessarily represent the life of the Power Supply. Life expectancy 10 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. 10 S8VM 15W/30W 50W/100W/150W (5 V) Intermittent operation Output voltage (V) Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive voltage that is approximately 140% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Output voltage (V) ■ Overvoltage Protection The Power Supply is provided with an overload protection function that protects the Power Supply from possible damage by short-circuit and overcurrent. When the output current rises above 105% min. of the rated current, the protection function is triggered, automatically decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Output voltage (V) ■ Overload Protection Overvoltage protection operating Approx. 40% Variable range +20% *1 Rated output voltage Intermittent operation *2 −10% 50 0 100 Output current (%) 50 100 Output current (%) 50W/100W/150W (12 V, 15 V, 24 V) 300W/600W/1,500W Output voltage (V) 0 Note: Refer to page 17. −20% 0V The values shown in the above diagram are for reference only. *1 S8VM-@@@24A@/P@ *2 Except for S8VM-@@@24A@/P@ 0 Note: 1. Do not turn ON the input power again until the cause of the overvoltage has been removed. 2. The overvoltage protection function may be activated when the output voltage adjuster (V.ADJ) is set to a value that exceeds +20% of the rated output voltage. 3. When the +S and −S terminals are opened with the shortbar removed, the overvoltage protection function is activated and the output voltage will be cut off. 50 100 Output current (%) The values shown in the above diagrams are for reference only. Note: 1. Internal parts may occasionally deteriorate or be damaged if a short-circuited or other overcurrent state continues during operation. Do not continue an overload state for longer than 30 seconds. Eliminate the overcurrent state as soon as possible. 2. Internal parts may possibly be deteriorated or damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. ■ Undervoltage Alarm Function (Indication and Output) (Only S8VM-@@@24A@/P@) If an output voltage drop is detected with an S8VM-@@@24A@/P@ with undervoltage alarm function, the DC LOW indicator will light to notify of an output error. The transistor also sends an output externally to notify of the error (except for the S8VM-01524A@ and S8VM-03024A@). Transistor Output: Sinking type: (NPN) (S8VM-@@@24A@) Sourcing type: (PNP) (S8VM-@@@24P@) 30 VDC max., 50 mA max., Residual voltage when ON: 2 V or less, Leakage current when OFF: 0.1 mA or less S8VM-01524A@ S8VM-05024A@/P@ S8VM-10024A@/P@ S8VM-15024A@/P@ S8VM-03024A@ 8 9 10 4 4 7 6 4 8 9 10 6 7 7 6 10 9 8 4 7 6 • Undervoltage Alarm Function 1 (DC LOW1) Only a momentary voltage drop is detected. Detection voltage is automatically adjusted internally by detecting the output voltage (approx. 2.7 V lower than the voltage output at an output voltage of 24.0 V). During detection, the transistor is OFF (with no continuity across 8 and 10) and the LED (6: Yellow) lights. (The Undervoltage Alarm Function 1 is used as a latch holding function.) • Undervoltage Alarm Function 2 (DC LOW2) Detection voltage is set to approx. 20.0 V (from 18.0 to 21.6 V). During detection, the transistor is OFF (with no continuity across 9 and 10) and the LED (7: Red) lights. Note: 1. This function monitors the voltage at the Power Supply output terminals. To check actual voltage, measure voltage on the load side. 2. Gradual voltage drop is not detected by the Undervoltage Alarm Function 1 (DC LOW1). 3. Once a voltage drop in the output voltage is detected by Undervoltage Alarm Function 1 (DC LOW1), the transistor turns OFF and status of the LED (6: Yellow) light is maintained. To reset the function, turn OFF the input power for 60 seconds or longer, and then turn it ON again. 4. If the output voltage remains at 15 V or lower for several seconds when using Undervoltage Alarm Function 1 (DC LOW 1), the output hold status for detection may be reset. 11 S8VM ■ Probable Causes of Power Supply Errors and Troubleshooting Using Undervoltage Alarm Function Check the following information if the Undervoltage Alarm Function operates. Contact your OMRON representative if the Power Supply does not function normally after checking. The symbols in the table are as follows: : Lit, : Not lit, : Flashing Note: Flashing: The output voltage is unstable, causing the LED to repeatedly turn ON and OFF. DC ON LED D: Green DC LOW1 LED F: Yellow Transistor outputs (H to J) DC LOW2 LED G: Red Transistor outputs (I to J) Output voltage Power Supply status diagnosis 1 ON ON → Normal (approx. 90% min. Normal status of rated output voltage) 2 OFF ON → Normal (approx. 90% min. of rated output voltage) The output voltage has dropped gradually and remains low. Output drop (approx. 90% max. of rated output voltage) The output voltage remains low following a previous sudden voltage drop. The output voltage has recovered to normal status following a previous sudden voltage drop. ON OFF 4 OFF OFF → ON Output drop (approx. 80% of → rated output voltage) The output voltage remains low and is continuing to fluctuate following a previous sudden voltage drop. OFF Output drop (approx. 80% of → rated output voltage) The output voltage has dropped gradually, remains low, and is continuing to fluctuate. OFF OFF → No output No output voltage is being output. ON ON → Unstable output The output voltage is unstable. 5 OFF ⇔ 3 Output drop (approx. 90% → max. of rated output voltage) OFF 8 ⇔ 7 ON ⇔ 6 ⇔ ON OFF OFF 24 V 24 V 24 V 24 V 24 V 24 V 24 V 12 S8VM Probable cause of error Troubleshooting methods --- --- 1 A momentary power failure has occurred in the Check that the output voltage is normal and no problems have occurred in other devices. No problems input. will be caused by continuing to use the Power Supply as is. To clear DC LOW1 (LED display and transistor output status), turn OFF the input power, and wait at least 60 s before turning ON the input Power Supply again. A momentary overload has occurred. The load current has probably exceeded the rated current. We suggest reducing the connected load or replace the Power Supply with one that has a higher capacity. A momentary output voltage drop has occurred A large inrush current has probably flowed to the load side at startup. We suggest replacing the Power 2 at startup due to the capacity of the capacitive Supply with one that has a higher capacity. factors on the load side or when the load is activated. The output voltage has returned to normal volt- Turn OFF the input power, and wait at least 60 s before turning ON the input power again to clear the age following a rapid drop caused by using the indicator status. output voltage adjuster (V.ADJ). Deterioration due to age (when the Power Sup- The internal parts of the Power Supply may have deteriorated due to age. We suggest replacing the ply has been used for several years) Power Supply. Also replace other Power Supplies that were purchased at the same time. Overload (immediately following first use of the The load current has probably exceeded the rated current. Check the actual load current and Power Power Supply or when increasing the load) Supply capacity. Continued use in overload status may damage the Power Supply. 3 The output voltage dropped to -10% or lower of Adjust the output voltage to the rated values using the output voltage adjuster (V.ADJ). the rated voltage resulting from using the output voltage adjuster (V.ADJ) A sudden overload occurred and the Power An error has probably occurred in the load device. Turn OFF the input power, and check whether any Supply remains in overload status. errors have occurred in the load device. Continued use in overload status may damage the Power Supply. The output voltage remains low after a rapid Adjust the output voltage to the rated values using the output voltage adjuster (V.ADJ). To clear DC voltage drop caused by using the output voltage LOW1 (LED display and transistor output status), turn OFF the input power, and wait at least 60 s beadjuster (V.ADJ). fore turning ON the input power again. The overload status continues to fluctuate following a sudden overload. An error has probably occurred in the load device. Turn OFF the input power, and check whether any errors have occurred in the load device. Continued use in overload status may damage the Power Supply. 4 5 Deterioration due to age (after using the Power The internal parts of the Power Supply may have deteriorated due to age. Replace the Power Supply. Supply for several years) Also replace other Power Supplies that were purchased at the same time. Overload (immediately following first use of the The load current has probably exceeded the rated current. Check the actual load current and Power Power Supply or when increasing the load) Supply capacity. Continued use in overload status may damage the Power Supply. 6 Power Supply interrupted or damaged. Check whether the input power is being applied correctly. If there is no output even though the input power is applied correctly, the internal circuit is probably damaged. Overvoltage protection operation Turn OFF the input power, and wait at least 3 min before turning ON the input power again. If the same status recurs, the internal circuit is probably damaged. 7 The short bar has fallen off, or the +S and -S ter- Check whether the +S and -S terminals are open. If so, the overvoltage protection function is activated. minals are open. Therefore, turn OFF the input power and wait at least three minutes before turning it ON again. (S8VM10024A@/P@ and S8VM-15024A@/P@ models only) Output short-circuit Remove the cause of the output short-circuit. Intermittent operation due to overload (S8VM- The load current has probably exceeded the rated current. Check the actual load current and Power 01524A@/03024A@ only) Supply capacity. Continued use in overload status may damage the Power Supply. The Power Supply fails to start repeatedly due A large inrush current has probably flowed to the load side at startup. We suggest replacing the Power to the capacity of the capacitive factors on the Supply with one that has a higher capacity. 8 load side. The input turns ON and OFF repeatedly. Check whether the Power Supply’s input voltage is being applied correctly. The status repeatedly switches between normal An error has probably occurred in the load device. Turn OFF the input power, and check whether any operation and output short-circuit. errors have occurred in the load device. 13 S8VM Construction and Nomenclature (300-W, 600-W, 1,500-W Models) ■ Nomenclature No. 300-W Models 2 PE terminal: Protective earth- Connect the ground line to this terminal. (See note 2.) ing terminal ( ) (S8VM-300@@C/S8VM600@@C) FG terminal: Frame ground terminal (S8VM-15224C) Connect the input lines to these terminals. (See note 1.) 3 DC output terminals (−V), (+V) Connect the load lines to these terminals. 4 Output indicator (DC ON: Green) Lights (green) while a direct current (DC) output is ON. 5 Output voltage adjuster (V.ADJ) Use to adjust the voltage. 6 Power failure alarm indicator (PF: Red) Lights when the output voltage decreases, the fan stops, and the system is on standby using the remote control function. 7 Signal I/O connector (See note 1: 3.) 2: 3: 4: 2 1 5: 6: 4 3 6 8 10 12 S8VM-600@@C Function AC input terminals (L), (N) S8VM-300@@C 600-W Models Name 1 5 7 9 11 CN DC output monitor pin (+V) Remote sensing pin (+S) DC output monitor pin (−V) Remote sensing pin (−S) Current balance pin (CB) Signal ground pin for current balance (CBG) 7: Remote control pin (+RC) 8: Remote control pin (−RC) 9: No connect 10: No connect 11: Power failure alarm output pin (PF-C) (collector) 12: Power failure alarm output pin (PF-E) (emitter) Note: 1. The fuse is located on the (L) side. It is NOT user-replaceable. 2. Protective earthing connection is the panel mounting hole of the metal case. (A protective earthing connection stipulated in safety standards is used. Connect the ground completely). Ground terminal: M4 (Depth: 6 mm max.)/Ground wire: AWG 18 3. The standard supplied connector for signal I/O is mounted to CN when S8VM is shipped. The supplied signal I/O connector shorts between 1 and 2, between 3 and 4, and between 7 and 8. The stability and accuracy of the output will deteriorate if the connector is removed. Always connect the +S and -S pins. Do not connect a load to the output voltage monitor terminals (+V, −V). 1,500-W Model S8VM-15224C ■ Output Color Label This color label identifies the output voltage by color. Green: Blue: Yellow: White: 5V 12 V 15 V 24 V Color label identifying output voltage Note: A 300-W model is shown above. The label is in a different place on 600-W models and 1,500-W model. 14 S8VM Engineering Data (300-W, 600-W, 1,500-W Models) ■ Derating Curve Upside-down Mounting (S8VM-15224C Only) Correct Load ratio (%) 300W/600W/1,500W 120 100 1,500 W 80 *1 Side Mounting 60 Incorrect Incorrect 300 W 600 W Incorrect 40 20 0 −20 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) Note: 1. Internal parts may occasionally be deteriorated or damaged. Do not use the Power Supply in areas outside the derating curves (i.e., the area shown by shading A in the above graph). 2. When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them. Always provide at least 50 mm of mounting space for the surface with the fan mounted. Be sure to provide at least 50 mm (S8VM300@@C/600@@C) or 100 mm (S8VM-15224C) of mounting space on the opposite side of the surface with the fan mounted. 3. When using the 1,500-W model for a long period of time at an input voltage of 90 VAC or lower, reduce the load to 80% or less of the above derating curve. 4. The ambient temperature is specified at a location 50 mm in front of the center of the Power Supply's front panel. Standard Mounting Correct Note: 1. The internal parts may occasionally deteriorate or be broken due to adverse heat dissipation depending on the mounting status. Do not use the Power Supply in any mounting direction other than those specified. 2. Use the metal plate as the mounting panel (*1). 3. To ensure sufficient cooling, do not cover the air holes located on the side the fan is mounted and the opposite side. 4. Mounting screw tightening torque (recommended value: M4 (1.27 N·m)) The screws must not protrude more than 6 mm inside the Power Supply. ■ Remote Sensing Function This function is used to compensate for voltage drops on the load lines. Connect the +S pin (pin 2 on CN) to the positive load terminal and the −S pin (pin 4 on CN) to the negative load terminal to enable remote sensing. When not using the remote sensing function, use the standard supplied connector. The +S and +V pins (pin 1 on CN) and the −S and −V pins (pin 3 on CN) will be connected. ■ Mounting Correct 1,500 W Correct +V + S8VM −V CN 300 W 600 W *1 *1 1,500 W +V +S −V *1 *2 −S *1 Horizontal Mounting Correct 300 W Correct *1 600 W Correct *1 1,500 W *1 Note: 1. Use 2-conductor shielded cable as connection wire (* 1). 2. Use as thick a wire as possible since high voltage drops on the load lines (* 2) may activate the overvoltage protection function. 3. Use when the voltage drop is 0.3 V or lower. 4. If the sensing line is too long, it is necessary to put an electrolytic capacitor across the load terminals. The electrolytic capacitor may generate heat due to the ripple current, depending on connected load. Therefore, the electrolytic capacitor must have a ripple current allowance higher than the output ripple current. 5. The stability and accuracy of the output will deteriorate if the short bar is missing or if the +S and −S pins are open. Always connect the +S and −S pins. 6. Remove the standard supplied connector and prepare a connector harness separately. 15 S8VM ■ Remote Control Function This function turns outputs ON and OFF using an external signal while input voltage is applied, using the +RC pin (pin 7 on CN) and the -RC pin (pin 8 on CN). Connect a switch or transistor to the +RC and -RC pins to use the remote control function. When not using this function, the +RC and -RC pins are shorted by using the standard supplied connector. ■ Inrush Current, Startup Time, Output Hold Time Input OFF Input ON AC input voltage +RC S8VM SW CN Inrush current on input application TR −RC AC input current 95% 90% +RC Level for −RC Output voltage Built-in Fan Motor Short or L (0 to 0.8 V) ON Rotate Open or H (2.4 to 12 V) OFF Stop Maximum input voltage: 12 V max. Maximum allowable reverse voltage: −1 V max. Sink Current: 3.5 mA Output voltage Startup time Hold time Note: A maximum input surge current of approx. 40 A will flow at startup even when not turning ON the input. Consider this surge current when selecting the input switch, input breaker, or external fuse. Note: 1. Use 2-conductor shielded cable or twisted-pair cable as connection wire. 2. The remote control circuit is isolated from the input and output circuits of the power supply. 3. Remove the standard supplied connector and prepare a connector harness separately. ■ Input Current Waveform When Input Is Turned ON ■ Power Failure Alarm Function S8VM-300@@C The power failure alarm indicator will light red to indicate an output voltage error if overload, overvoltage, or overheat protection is activated, if a drop in the input voltage causes the output voltage to drop, if the built-in fan motor stops, and during remote control standby. The alarm is also output externally by a transistor. Transistor output: 30 VDC max., 50 mA max. The following examples show typical waveforms. 100 VAC, Load ratio: 100% 100 ms AC input current (10 A/DIV) Residual voltage when ON: 2 V max. Leakage current when OFF: 0.1 mA max. Alarm detection voltage: Approx. 80% of output voltage setting During detection, the transistor is OFF (with no continuity across pins 11 and 12 on CN), and the LED (red) lights. CN Output voltage AC input voltage 200 VAC, Load ratio: 100% PF-C S8VM 100 ms PF-E Vce max.: 30 VDC Ic max.: 50 mA Note: 1. This function monitors the voltage at the power supply output terminals. To check actual voltage, measure the voltage on the load side. 2. Outputs are forced OFF if the built-in fan motor stops (S8VM-15224C only). 3. Remove the standard supplied connector and prepare a connector harness separately. AC input current (10 A/DIV) Output voltage AC input voltage 16 S8VM S8VM-600@@C ■ Reference Values 100 VAC, Load ratio: 100% 100 ms AC input current (10 A/DIV) Value Definition Reliability (MTBF) Item 300 W: 135,000 hrs 600 W: 120,000 hrs 1,500 W: 100,000 hrs MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates the reliability of a device. Therefore, it does not necessarily represent the life of the Power Supply. Life expectancy 10 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. ■ Overload Protection Output voltage AC input voltage 200 VAC, Load ratio: 100% 100 ms The Power Supply is provided with an overload protection function that protects the Power Supply from possible damage by overcurrent. When the output rises above 105% of the rated current, the protection function is triggered, automatically decreasing the output voltage. S8VM-300@@C/600@@C When the output current returns within the rated range, overload protection is automatically cleared. AC input current (10 A/DIV) S8VM-15224C AC input voltage S8VM-15224C 100 VAC, Load ratio: 100% 100 ms 300W/600W (5 V) 300W600W/1,500W (12 V, 15 V, 24 V) Output voltage (V) Output voltage Output voltage (V) Outputs are interrupted if an overload continues for 5 seconds or more. To reset the Power Supply, leave the input power OFF for more than 3 minutes and then turn it ON again. Alternatively, turn OFF and ON the remote control signal. Intermittent operation AC input current (25 A/DIV) 0 50 100 Output current (%) 0 50 100 Output current (%) The values shown in the above diagrams are for reference only. Output voltage AC input voltage 200 VAC, Load ratio: 100% Note: 1. If the Power Supply has been short-circuited or supplied with an overcurrent for longer than 30 seconds, the internal parts of the Power Supply may occasionally be deteriorated or damaged. 2. The internal parts may possibly be deteriorated or damaged. Do not use the Power Supply for applications where the load causes frequent inrush current and overload. 100 ms AC input current (10 A/DIV) Output voltage AC input voltage 17 S8VM ■ Overvoltage Protection Output voltage (V) Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive voltage that is approximately 140% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Alternatively, turn OFF and ON the remote control signal. Overvoltage protection operating Approx. 40% +20% Rated output voltage Variable range −20% 0V The values shown in the above diagram are for reference only. Note: 1. Do not turn ON the input power again until the cause of the overvoltage has been removed. 2. The overvoltage protection function may be activated when the output voltage adjuster (V.ADJ) is set to a value that exceeds +20% of the rated output voltage. ■ Overheat Protection The overheat protection circuit will operate and outputs will be shut OFF to protect the Power Supply if the ambient temperature rises, the fan stops, or other errors cause the Power Supply's internal temperature to rise. To reset the Power Supply, leave the input power OFF long enough for the Power Supply to cool sufficiently and then turn it ON again. Alternatively turn OFF the remote control signal long enough to cool sufficiently and then turn it ON again. ■ Peak Output Current (S8VM-30024C/60024C/15224C Only) The peak current must satisfy the following conditions. Reduce the peak current according to the load rate of the derating curve. Input voltage range: 180 to 240 VAC Peak current pulse width: 10 s max. Duty: 35% max. Peak current value: Within the rated peak current Effective output current: Within the rated current Ip Irms Ia 0A τ T Ip: Irms: lav: la: D: τ: T: Peak current (A) Effective output current (A) Rated current (A) Continuous load current (A) Duty Peak current pulse width (s) Cycle (s) Irms= lp2 × D + la2× (1−D) ≤ lav τ D= T 18 S8VM Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Bottom Mounting Models (15-W, 30-W, 50-W, 100-W, 150-W Models) S8VM-015@@ S8VM-015@@C S8VM-01524A 80.5 17.6 max. 27 81.5 68±0.5 8.5±0.5 62±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 Five, M3.5 terminal screws Mounting Holes Bottom View Side Mounting 15.5±0.5 67±0.3 Two, M3 (depth: 8 max.) 8.5±0.5 Note: The image is the S8VM-01524 Model. Two, 4 dia. 68±0.5 84.5 13.6 max. 33.5 62±0.5 84.5 68±0.5 Bottom Mounting Two, 4 dia. 8.5±0.5 Two, M3 (depth: 8 max.) 67±0.3 62±0.5 8.5±0.5 Five, M3.5 terminal screws 15.5±0.5 Note: The image is the S8VM-01524A Model. 67±0.3 Two, M3 (depth: 8 max.) 8.5±0.5 S8VM-030@@ S8VM-030@@C S8VM-03024A 17.6 max. 95.5 27 82.5 68±0.5 Mounting Holes 8.5±0.5 Two, M3 (depth: 8 max.) 77±0.5 8.5±0.5 Side Mounting 15.5±0.5 82±0.3 Note: The image is the S8VM-03024 Model. Bottom View Five, M3.5 terminal screws Two, 4 dia. Two, M3 (depth: 8 max.) 8.5±0.5 68±0.5 99.5 13.6 max. 33.5 77±0.5 84.5 68±0.5 Bottom Mounting Two, 4 dia. 82±0.3 8.5±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 77±0.5 Five, M3.5 terminal screws 15.5±0.5 Note: The image is the S8VM-03024A Model. 8.5±0.5 82±0.3 Two, M3 (depth: 8 max.) 19 S8VM S8VM-050@@ S8VM-050@@C S8VM-05024A S8VM-05024P 120.5 17.6 max. 27 82.5 68±0.5 Mounting Holes Bottom View 8.5±0.5 97±0.5 Two, M3 (depth: 8 max.) 23.5±0.3 8.5±0.5 Side Mounting Five, M3.5 terminal screws Two, 4 dia. 15±0.2 83±0.5 8±0.2 68±0.5 Three, M3 (depth: 4 max.) 32.5±0.5 Note: The image is the S8VM-05024 Model. 124.5 13.6 max. 97±0.5 33.5 Bottom Mounting Three, 4 dia. 15±0.2 68±0.5 84.5 83±0.5 8±0.2 8.5±0.5 Two, M3 (depth: 8 max.) 23.5±0.3 97±0.5 8.5±0.5 Five, M3.5 terminal screws 15±0.2 8±0.2 83±0.5 Three, M3 (depth: 4 max.) 32.5±0.5 Note: The image is the S8VM-05024A Model. S8VM-100@@ S8VM-100@@C S8VM-10024A S8VM-10024P 160.5 17.6 max. 28.5 68±0.5 Two, M4 terminal screws (+V, −V) 82.5 8.5±0.5 Two, M3 (depth: 8 max.) 135±0.5 8.5±0.5 Five, M3.5 terminal screws (+S, −S, , input) Mounting Holes 25±0.2 Bottom View 15±0.2 7.5±0.2 Three, M3 (depth: 4 max.) 120±0.5 30±0.5 Side Mounting Two, 4 dia. Note: The image is the S8VM-10024 Model. Two, M4 terminal screws (+V, −V) 164.5 13.6 max. 68±0.5 35 135±0.5 68±0.5 84.5 Bottom Mounting Three, 4 dia. 15±0.2 7.5±0.2 8.5±0.5 Two, M3 (depth: 8 max.) 25±0.2 8.5±0.5 135±0.5 120±0.5 Five, M3.5 terminal screws (+S, −S, , input) 15±0.2 7.5±0.2 30±0.5 120±0.5 Three, M3 (depth: 4 max.) Note: The image is the S8VM-10024A Model. 20 S8VM S8VM-150@@ S8VM-150@@C S8VM-15024A S8VM-15024P 160.5 17.6 max. Two, M4 terminal screws (+V, −V) 37.5 82.5 68±0.5 8.5±0.5 Two, M3 (depth: 8 max.) 135±0.5 8.5±0.5 Five, M3.5 terminal screws (+S, −S, , input) Mounting Holes Bottom View 26.5±0.2 Side Mounting 15±0.2 7.5±0.2 120±0.5 Two, 4 dia. Three, M3 (depth: 4 max.) 25±0.5 68±0.5 Note: The image is the S8VM-15024 Model. 135±0.5 Bottom Mounting 164.5 Two, M4 terminal screws (+V, −V) 13.6 max. 44 Three, 4 dia. 15±0.2 7.5±0.2 120±0.5 84.5 68±0.5 8.5±0.5 135±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 26.5±0.2 Five, M3.5 terminal screws (+S, −S, , input) 15±0.2 7.5±0.2 25±0.5 120±0.5 Three, M3 (depth: 4 max.) Note: The image is the S8VM-15024A Model. 21 S8VM ■ DIN Rail Mounting Bracket Models (15-W, 30-W, 50-W, 100-W, 150-W Models) S8VM-015@@D S8VM-015@@CD S8VM-01524AD 14 17.6 max. 80.5 33 3.5 max. 81.5 90.4 Five, M3.5 terminal screws 5.4 (Sliding: 9 max.) Note: The image is the S8VM-01524D Model. 14 84.5 15 max. 3.5 max. 35.1 84.5 46.2 Five, M3.5 terminal screws 94.4 5.4 (Sliding: 9 max.) Note: The image is the S8VM-01524AD Model. S8VM-030@@D S8VM-030@@CD S8VM-03024AD 14 17.6 max. 95.5 3.5 max. 33 82 105.4 Five, M3.5 terminal screws 5.4 (Sliding: 9 max.) Note: The image is the S8VM-03024D Model. 14 99.5 15 max. 3.5 max. 35.1 84.5 46.2 5.4 (Sliding: 9 max.) 109.4 Five, M3.5 terminal screws Note: The image is the S8VM-03024AD Model. 22 S8VM S8VM-050@@D S8VM-050@@CD S8VM-05024AD S8VM-05024PD 14 17.6 max. 120.5 3.5 max. 33 82.5 130.4 Five, M3.5 terminal screws 5.4 (Sliding: 9 max.) Note: The image is the S8VM-05024D Model. 14 124.5 15 max. 3.5 max. 35.1 84.5 46.2 5.4 (Sliding: 9 max.) Five, M3.5 terminal screws 134.4 Note: The image is the S8VM-05024AD Model. Two, M4 terminal screws (+V, −V) S8VM-100@@D S8VM-100@@CD S8VM-10024AD S8VM-10024PD 14 160.5 17.6 max. 3.5 max. 33 82.5 170.4 Five, M3.5 terminal screws (+S, −S, 5.4 (Sliding: 9 max.) Note: The image is the S8VM-10024D Model. 14 15 max. 164.5 3.5 max. , input) Two, M4 terminal screws (+V, −V) 36.6 84.5 46.2 5.4 (Sliding: 9 max.) 174.4 Five, M3.5 terminal screws (+S, −S, , input) Note: The image is the S8VM-10024AD Model. 23 S8VM Two, M4 terminal screws (+V, −V) S8VM-150@@D S8VM-150@@CD S8VM-15024AD S8VM-15024PD 14 160.5 17.6 max. 3.5 max. 39.1 82.5 170.4 5.4 (Sliding: 9 max.) Five, M3.5 terminal screws (+S, −S, , input) Note: The image is the S8VM-15024D Model. 14 15 max. 164.5 3.5 max. Two, M4 terminal screws (+V, −V) 45.6 84.5 46.2 174.4 Five, M3.5 terminal screws (+S, −S, , input) 5.4 (Sliding: 9 max.) Note: The image is the S8VM-15024AD Model. 24 S8VM ■ Bottom Mounting Models (300-W, 600-W, 1,500-W Models) S8VM-300@@C Mounting Holes Four, M4 (depth: 6 max.) 188 max. 22 max. 105±0.5 Bottom View 25.6±0.5 Standard Mounting Four, 4.5 dia. 83.5 60±0.5 40±0.5 120±0.5 11 22 max. 120±0.5 62.5 25.6±0.5 10.5 Seven, M4 terminal screws Horizontal Mounting 40±0.5 Four, 4.5 dia. 60±0.5 105±0.5 Four, M4 (depth: 6 max.) Note: The image is the S8VM-30024C Model. S8VM-600@@C Four, M4 (depth: 6 max.) Four, M5 terminal screws Mounting Holes 192 max. 25 26 max. 120±0.5 Bottom View Standard Mounting 83.8 Four, 4.5 dia. 40±0.5 60±0.5 21 101.8 110±0.5 Three, M4 terminal screws 20 Horizontal Mounting Four, 4.5 dia. 60±0.5 40±0.5 120±0.5 46 max. 110±0.5 Four, M4 (depth: 6 max.) Note: The image is the S8VM-60024C Model. S8VM-15224C Four, M4 (depth: 6 max.) Two, M8 bolts and nuts 126.5 46 max.10 Mounting Holes 327 max. Bottom View 260±0.5 82 Standard Mounting Four, 4.5 dia. 60±0.5 112±0.5 Four, M4 terminal screws 11 M8 (See note.) 10 260±0.5 260±0.5 7.25 112±0.5 Horizontal Mounting Four, 4.5 dia. 60±0.5 260±0.5 Four, M4 (depth: 6 max.) Note: M8 bolts and nuts for the output terminals are not included. 25 S8VM ■ Mounting Brackets Name Model Mounting Bracket A (bottom mounting for 15-, 30-, and 50-W models) S82Y-VM10B Mounting Bracket B (bottom mounting for 100- and 150-W models) S82Y-VM20B Mounting Bracket C (front mounting for 15-, 30-, 50-, 100-, and 150-W models) S82Y-VM10F Mounting Bracket D (bottom mounting for 300-W models) S82Y-VM30B Mounting Bracket E (horizontal bottom mounting for 300-W models) S82Y-VM30S Mounting Bracket F (front mounting for 300-W models) S82Y-VM30F Mounting Bracket G (DIN Rail mounting for 300-W models) S82Y-VM30D Mounting Bracket H (bottom mounting for 600-W models) S82Y-VM60B Mounting Bracket I (horizontal bottom mounting for 600-W models) S82Y-VM60S Mounting Bracket J (front mounting for 600-W models) S82Y-VM60F Mounting Bracket K (DIN Rail mounting for 600-W models) S82Y-VM60D Mounting Bracket A (Bottom Mounting for 15-, 30-, and 50-W Models) S82Y-VM10B Using the Mounting Bracket a = Mounting holes for 15-W models b = Mounting holes for 30-W models c = Mounting holes for 50-W models c a b b a, c c R2 Three, M3.5 B 20±0.5 35 B 7.5 5 5 B 4 Screws Used A: Accessories (Use the supplied screws in two places for 15-W and 30-W models and in three places for 50-W models.) B: M3 or M3.5 (three places) Mounting screw tightening torque (recommended): 0.49 N·m 4 dia. 140±0.5 R2 150 A t = 2.3 A A Mounting Bracket B (Bottom Mounting for 100-, and 150-W Models) S82Y-VM20B Using the Mounting Bracket a = Mounting holes for 150-W models b = Mounting holes for 100-W models b a b a b a R2 4 B 15±0.2 Three, M3.5 5 20±0.5 40 4 dia. 182±0.5 192 t = 2.3 B A B Screws Used A: Accessories (Use the supplied screws in three places.) B: M3 or M3.5 (three places) Mounting screw tightening torque (recommended): 0.49 N·m A A 26 S8VM Mounting Bracket C (Front Mounting for 15-, 30- 50-, 100-, and 150-W Models) S82Y-VM10F 58 15 33 4 dia. Using the Mounting Bracket 5 B A A 105 97±0.5 80 R2 A B B 8.3 a, b 4 13.4 c d, e d, e t = 1.6 a, b, c, d, e Screws Used A: Accessories (Use the supplied screws in two places for 15-W, 30-W and 50W models and in three places for 100-W and 150-W models.) B: M3 or M3.5 (three places) Mounting screw tightening torque (recommended): 0.49 N·m a = Mounting holes for 15-W models b = Mounting holes for 30-W models c = Mounting holes for 50-W models d = Mounting holes for 100-W models e = Mounting holes for 150-W models Mounting Bracket D (Bottom Mounting for 300-W Models) S82Y-VM30B Using the Mounting Bracket Three, 4.5 dia. B 48 60 B 5 195 B A A A A Screws Used A: Accessories (Use the supplied screws in four places.) B: M4 (three places) Mounting screw tightening torque (recommended): 1.27 N·m 27 S8VM Mounting Bracket E (Horizontal Bottom Mounting for 300-W Models) S82Y-VM30S Using the Mounting Bracket B 52 84 B 16 8 6 202 215 B Three, 4.5 dia. A A A A Screws Used A: Accessories (Use the supplied screws in four places.) B: M4 (three places) Mounting screw tightening torque (recommended): 1.27 N·m Mounting Bracket F (Front Mounting for 300-W Models) S82Y-VM30F Using the Mounting Bracket Two, 4.5 dia. B 60 48 5 B 102.3 105 B 13.5 4.5 67 215.3 A 243 max. A A A Screws Used A: Accessories (Use the supplied screws in four places.) B: M4 (three places) Mounting screw tightening torque (recommended): 1.27 N·m 28 S8VM Mounting Bracket G (DIN Rail Mounting for 300-W Models) S82Y-VM30D Using the Mounting Bracket 5.5 60 102.3 46 215.3 67 6.6 (Sliding: 12 max.) Screws Used A: Accessories (Use the supplied screws in four places.) Mounting screw tightening torque (recommended): 1.27 N·m 243 max. 9.5 A A Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail. A A Mounting Bracket H (Bottom Mounting for 600-W Models) S82Y-VM60B Using the Mounting Bracket B 72 B 100 Three, 4.5 dia. 8 6 Screws Used A: Accessories (Use the supplied screws in four places.) B: M4 (three places) Mounting screw tightening torque (recommended): 1.27 N·m 202 215 B A A A A Mounting Bracket I (Horizontal Bottom Mounting for 600-W Models) S82Y-VM60S Using the Mounting Bracket B B 52 84 Three, 4.5 dia. 16 8 6 202 215 B A A A A Screws Used A: Accessories (Use the supplied screws in four places.) B: M4 (three places) Mounting screw tightening torque (recommended): 1.27 N·m 29 S8VM Mounting Bracket J (Front Mounting for 600-W Models) S82Y-VM60F Using the Mounting Bracket Two, 4.5 dia. B 98 82 5 B 105 102.3 B 13.5 222.3 4.5 105 257 max. Screws Used A: Accessories (Use the supplied screws in four places.) B: M4 (three places) Mounting screw tightening torque (recommended): 1.27 N·m A A A A Mounting Bracket K (DIN Rail Mounting for 600-W Models) S82Y-VM60D Using the Mounting Bracket 98 102.3 105 222.3 6.6 (Sliding: 12 max.) 257 max. 9.5 Note: Use a metal DIN Rail when mounting a 600-W model to a DIN Rail. A A A A Screws Used A: Accessories (Use the supplied screws in four places.) Mounting screw tightening torque (recommended): 1.27 N·m 30 S8VM ■ Other Items Sold Separately Name Model Undervoltage Alarm Output Wiring Cable S82Y-VM10H Signal I/O Connector Terminals and Housing Set contains ten SPHD-001T-P0.5 Terminals and one PHDR-12VS Housing. S82Y-VM30C Replacement Fan Unit for 300-W Models S82Y-VM30FAN Replacement Fan Unit for 600-W Models S82Y-VM60FAN Replacement Fan Unit for a 1,500-W Model S82Y-VM15FAN Undervoltage Alarm Output Wiring Cable S82Y-VM10H (for S8VM-05024A@/05024P@/10024A@/10024P@/15024A@/15024P@ Only) Using the Undervoltage Alarm Output Wiring Cable : to XHP-3 (Manufactured by JST) : AWG24 3,000±50 Note: The signal I/O connector can be connected in only one orientation. It cannot be connected if it is upside down. ■ Signal I/O Connector Terminals and Housing S82Y-VM30C (for the S8VM-300@@C/600@@C/15224C) The S82Y-VM30C is used to make a signal I/O connector. Refer to Signal I/O Connector Harness Manufacture Method on page 33 for details. ■ DIN Rail Note: All units are in millimeters unless otherwise indicated. Mounting Rail (Material: Aluminum) PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 25 10 25 27±0.15 1 15(5) * 1,000 (500) * *Values in parentheses are for the PFP-50N. Mounting Rail (Material: Aluminum) 16 PFP-100N2 4.5 35±0.3 27 15 25 10 25 25 1,000 10 25 15 24 29.2 1 1.5 Mounting Rail (Order Separately) End Plate PFP-M 10 6.2 M4 × 8 pan-head screw 50 1.8 1 1.8 35.5 35.5 11.5 1.3 10 M4 spring washer 4.8 Note: If there is a possibility that the Unit will be subjected to vibration or impact, metallic filings may be generated by abrasion. In this situation, use a metal DIN Rail. Also, if the Unit may be subjected to sliding to either side, attach an End Plate (Model PFP-M) on each side of the Unit. 31 S8VM Safety Precautions Refer to Safety Precautions for All Power Supplies. Standard Mounting Standard Mounting (DIN Rail Mounting Bracket Models) (Bottom Mounting Models) !CAUTION (See note 1.) (See note 1.) Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. (See note 1.) Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Fire may occasionally occur. Tighten terminal screws to the specified torque. 15-, 30-, 50-, 100-, and 150-W models (1.6 N·m) 300-, 600-, and 1,500-W models (M4; 1.6 N·m, M5; 2.50 N·m, M8 bolts and nuts; 10.8 N·m) (See note 1.) (See note 3.) Horizontal Mounting Face-up Mounting (See note 1.) (See note 1.) (See note 2.) Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Capacity 15 W The amount of installation spacing required between Power Supplies depends on the capacity. Refer to the following table. 15/30/50/100/150-W Models Natural cooling is used, so mount the Power Supply so that there is airflow around it. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the Power Supply within the derating curve for the mounting direction that is used. The internal parts may possibly be damaged if mounting screws are over inserted. Refer to Dimensions on page 19 to 21 for maximum depth of insertion inside the Power Supply. 20 mm min. 50 W 100 W 50 mm min. (See note.) (See note 1.) 150 W 3. A metal plate is recommended as the mounting surface. Mounting When cutting out holes for mounting, make sure that cuttings do not enter the interior of the Power Supply. (See note 3.) Dimensions 30 W ■ Precautions for Safe Use Use the metal plate as the mounting panel. (See note 3.) Note: 1. Convection of air 2. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Ensure sufficient heat dissipation when installing the Power Supply to increase its long-term reliability. (See note 2.) (See note 2.) Note: If more than one S8VM-100@@@@/150@@@@ Power Supply is mounted together, install them as far away from sources of heat as possible. If only 20 mm of space is available on the right and left sides of a Power Supply (see note 2.), use the Power Supply at a load ratio of 80% or less. 300/600/1,500-W Models A forced-air cooling method with a fan is used. To ensure sufficient cooling, do not cover the air holes located on the side the fan is mounted and the opposite side. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Do not use the Power Supply in any mounting direction other than those specified. The internal parts may possibly be damaged if mounting screws are over inserted. The screws must not protrude more than 6 mm inside the Power Supply. (See note 4.) (See note 2.) (See note 3.) (See note 1.) (See note 1.) (See note 5.) S8VM Note: 1. Convection of air 2. 50 mm or more 3. (S8VM-300@@C/600@@C): 50 mm or more (S8VM-15224C): 100 mm or more 4. 20 mm or more 5. Use a metal plate as the mounting panel. Wiring Connect the ground completely. A protective earthing connection stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely. Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. Do not apply more than 100-N force to the terminal block when tightening it. Be sure to remove the sheet covering the Power Supply for machining before power-ON so that it does not interfere with heat dissipation. 32 S8VM Use the following material for the wires to be connected to the S8VM to prevent smoking or ignition caused by abnormal loads. Over heating or fire can result from inadequately sized wiring materials when problems occur at the load. As a general rule, always select wire sizes suitable for at least 1.6 times the rated current. Refer to the wiring manufacturer's recommended allowable current and voltage drop specifications for information when selecting wiring materials. Recommended Wire Sizes Terminal Model Input S8VM-015@@@@ S8VM-030@@@@ S8VM-050@@@@ S8VM-100@@@@ S8VM-150@@@@ S8VM-300@@C S8VM-600@@C S8VM-15224C Output S8VM-015@@@@ S8VM-030@@@ S8VM-050@@@@ S8VM-100@@@@ S8VM-150@@@@ (M3.5) Recommended wire size AWG24 to AWG14 (0.205 to 2.081 mm2) (M4) AWG20 to AWG10 (0.52 to 5.27 mm2) (M3.5) AWG24 to AWG14 (0.205 to 2.081 mm2) Be sure to prepare the connector according to the following instructions to ensure correct wiring. For details, refer to the JST catalog. • Use a wire size of AWG26 to AWG22. • The guideline for the length of sheath to be stripped from the wire is 2.3 mm. • Use a YC Crimping Tool (manufactured by JST) to crimp the terminal and wire. • Applicable wire per barrel size is UL1007 (standard wire) and its equivalent standard wire can be used. Use UL1061 or its equivalent standard wire for AWG22 wires, because the wire insulation outer diameter of UL1061 is small. • Be sure to insert the crimped terminal wires into the housing fully until a click is heard. Also, make sure that the wires attached to the housing are securely locked in place. Installation Environment AWG24 to AWG12 (0.205 to 3.309 mm2) S8VM-30005/12C/15C AWG16 to AWG10 (M4) (1.32 to 5.27 mm2) S8VM-30024C Twisted wires (M4) AWG18 (0.81 mm2) S8VM-60005C/12C/15C AWG14 to AWG8 (M5) (2.08 to 8.3 mm2) S8VM-60024C Twisted wires (M5) AWG14 (2.08 mm2) S8VM-15224C (M8 bolts AWG8 to AWG4 and nuts) (8.3 to 21.09 mm2) (M4) The current rating for the output terminals on the S8VM-300@@C is 40 A per terminal. The current rating for the output terminals on the S8VM-600@@C is 60 A per terminal. Use two terminals together if a current exceeding the terminal rating is used. Use min. 60°C or 60/75°C wire. Use copper conductors only. Undervoltage Alarm Output Connector Harness Manufacture Method Do not use the Power Supply in locations subject to shocks or vibrations. In particular, install the Power Supply as far away as possible from contactors or other devices that are a vibration source. Install the Power Supply well away from any sources of strong, highfrequency noise and surge. Operating Life The life of a Power Supply is determined by the life of the electrolytic capacitors used inside. Here, Arrhenius Law applies, i.e., the life will be halved for each rise of 10°C or the life will be doubled for each drop of 10°C. The life of the Power Supply can thus be increased by reducing its internal temperature. Ambient Operating and Storage Environments Store the Power Supply at a temperature of −25 to 65°C and a humidity of 25% to 90%. The Internal parts may occasionally be deteriorated or damaged. Do not use the Power Supply outside the derating range (i.e., under conditions indicated by the shaded area ( ) in the derating curve diagrams on pages 9 and 15.) Use the Power Supply at a humidity of 30% to 85%. The following products are provided with the S8VM-05024A@/P@, S8VM-10024A@/P@ and S8VM-15024A@/P@ for the undervoltage alarm transistor output wiring. Do not use the Power Supply in locations subject to direct sunlight. Connector Overload Protection S8VMS8VM-10024A@/P@ Manu05024A@/P@ S8VM-15024A@/P@ factured by JST S3B-XH-A-1 BH3B-XH-2 Housing (provided) XHP-3 Terminal (provided) BXH-001T-P0.6 or SXH-001T-P0.6 Be sure to prepare the connector according to the following instructions to ensure correct wiring. For details, refer to the JST catalog. • Use a wire size of AWG28 to AWG22. • The guideline for the length of sheath to be stripped from the wire is 2.1 to 2.6 mm. • Use either a YC or YRS Crimping Tool (manufactured by JST) to crimp the terminal and wire. • Be sure to insert the crimped terminal wires into the housing fully until a click is heard. Also, make sure that the wires attached to the housing are securely locked in place. Signal I/O Connector Harness Manufacture Method The S8VM-300@@C/600@@C/15224C are using PHD connector (manufactured by JST). Connector S8VM-300@@C/600@@C/15224C S12B-PHDSS Housing PHDR-12VS Terminal SPHD-001T-P0.5 or BPHD-001T-P0.5 Manufactured by JST Do not use the Power Supply in locations where liquids, foreign matter, or corrosive gases may enter the interior of the Power Supply. If the Power Supply has been short-circuited or supplied with an overcurrent for longer than 30 seconds, the internal parts of the Power Supply may occasionally be deteriorated or damaged. Internal parts may possibly be deteriorated or damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. Dielectric Strength Test If a high voltage is applied between an input and the case (PE/FG), it will pass though the LC of the built-in noise filter and energy will be stored. If the high voltages used for dielectric strength testing are turned ON and OFF with a switch, timer, or similar device, impulse voltage will be generated when the voltage is turned OFF and internal parts may possibly be damaged. To prevent the generation of impulse voltages, reduce the applied voltage slowly with a variable resistor on the test device or turn the voltage ON and OFF at the zero-cross point. When performing the test, be sure to short-circuit all the output terminals to protect them from damage. Check the waveform of the applied voltage while testing. High voltage due to distortions of the applied voltage may be produced depending on the type of testing equipment. 33 S8VM Insulation Test Series Operation When performing the test, be sure to short-circuit all the output terminals to protect them from damage. Two Power Supplies can be connected in series. The (±) voltage output can be accomplished with two Power Supplies. Inrush Current Series Operation When two or more Power Supplies are connected to the same input, inrush current is added to the total current. Select fuses and circuit breakers giving sufficient consideration to the fusing or operating characteristics so that fuses will not burn and breakers will not break due to inrush current. Output Voltage Adjuster (V.ADJ) Default Setting: Set at the rated voltage Adjustable Range: Adjustable with output voltage adjuster (V.ADJ) on the front panel of the Power Supply from −20% to 20% of the rated output voltage (−10% to 20% of the rated voltage for S8VM@@@24A@/P@). Turning clockwise increases the output voltage and turning counterclockwise decreases the output voltage. The output voltage adjuster (V.ADJ) may possibly be damaged if it is turned with unnecessary force. Do not turn the adjuster with excessive force. After completing output voltage adjustment, be sure that the output capacity or output current does not exceed the rated output capacity or rated output current. The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged. When increasing the output voltage to more than +20% of the rated value using the output voltage adjuster (V. ADJ), the overvoltage protection function may operate. (S8VM-@@@24A@/P@ Only) Turn the output voltage adjuster (V.ADJ) slowly. When decreasing the output voltage quickly, or when adjusting the output voltage to less than −10% of the rated value, the undervoltage alarm function may operate. Ripple 15W/30W Correct 50W/100W/150W/300W/600W/ 1,500W Correct AC (L) +V AC (L) +V AC (N) −V AC (N) −V AC (L) +V AC (L) +V AC (N) −V AC (N) −V Output Voltage (±) Correct AC (L) +V AC (N) −V AC (L) +V AC (N) −V Note: 1. If the load is short-circuited, a reverse voltage may be applied inside the Power Supply unit, and this may possibly cause the deterioration or damage of the Power Supply unit. Connect the diode as shown in the figures. Use the following guidelines to select the diode to be connected. Type Schottky Barrier diode Dielectric strength Twice the rated output voltage or (VRRM) above Forward current (IF) Twice the rated output current or above 2. Though Power Supplies having different specifications can be connected in series, the current flowing through the load must not exceed the smaller rated output current. (S8VM-15224C Only) The rated ripple noise voltage was measured using a measuring circuit that conforms to the JEITA standard RC-9131A. Parallel Operation +V S8VM CN + C1 −V C2 +V +S −V −S 15/30/50/100/150-W Models Load The Power Supply is not designed for parallel operation. Coaxial cable 1.5 m 50 Ω R: 50 Ω C1: 4700 pF C2: 22 uF C3: 0.47 uF R C3 Oscilloscope Frequency band 100 MHz Dielectric Strength When testing the dielectric strength, some testing devices will apply a much higher voltage than expected. Always check the applied waveform before testing the dielectric strength. Incorrect AC (L) +V AC (N) −V AC (L) +V AC (N) −V Remote Sensing Function 100/150-W Models If the +S and −S terminals are opened by removing the short bar, the overvoltage protection function will be activated and the output voltage will be cut off. 300/600/1,500-W Models The stability and accuracy of the output will deteriorate if the +S and − S pins are open. Always connect the +S and −S pins. 34 S8VM 300/600/1,500-W Models Check the overheat protected status. If the CB pin (pin 5 on CN) and the CBG pin (pin 6 on CN) are connected, the current balance function will operate and parallel operation will be possible at 80% or less of the total output capacity. Turn OFF the input power and leave it OFF until the Power Supply cools sufficiently. Turn it ON again to see if this clears the condition. Up to 2 Power Supplies can be connected. Check if the built-in fan motor has stopped. Check if the built-in fan motor has stopped. The fan is a consumable part. Correct AC (N) CN CB AC (L) AC (N) +V Check the remote control function. −V Check if the +RC and -RC pins are open. Make the correct connections as specified. S8VM CB S8VM CBG *1 CBG CN +V −V Use 2-conductor shielded cable as connection wire (* 1). Adjust the output voltage of each Power Supply to the same value within 1% of the rated voltage or so that the difference in the output voltage is 100 mV or less, whichever is smaller, using the output voltage adjuster (V. ADJ). Parallel operation is used to increase static capacity. The output voltage may drop with sudden load fluctuations. There may be steps in the rising waveform of the output voltage during parallel operation. Remove the standard supplied connector and prepare a connector harness separately. In Case There Is No Output Voltage Fan Replacement 300/600/1,500-W Models Consult with OMRON regarding fan replacement. OMRON will replace fans for a fee. A replacement Fan Unit (S82Y-VM@@FAN) is available. Use the curve in the graph below as a rough measure of replacement timing. Expected service life (years) AC (L) 10 7 5 3 2 15/30/50/100/150-W Models The possible cause for no output voltage may be that the overload protection or overvoltage protection has operated. The internal protection circuit may operate if a large amount of surge voltage such as a lightening surge is applied to the input. If there is no output voltage even after checking the following points please contact your OMRON representative. 1 0 40 50 60 70 80 100 Exhaust temperature: °C Note: Expected fan service life Exhaust temperature 45°C: 45,000 hours Exhaust temperature 80°C: 11,000 hours The Power Supply will not conform to safety standards if the customer replaces the fan. Check the overload protected status. Check whether the load is in overload status or is short-circuited. Remove the load wires when checking. Attempt to clear the overvoltage or internal protection function. Turn OFF the input power once and leave it OFF for at least 3 minutes. Then turn it ON again to see if this clears the condition. Check whether the +S terminal and −S terminal are open, i.e., if the short bar has been removed. (S8VM-100@@@@/S8VM-150@@@@ only) Check if the output voltage has been adjusted to more than +20% of the rated voltage using the output voltage adjuster (V. ADJ). 300/600/1,500-W Models The possible cause for no output voltage may be that the overcurrent protection, overvoltage protection, or overheat protection has operated. Alternatively, the built-in fan may have stopped or the remote control function may be OFF. Buzzing Noise when the Input Is Turned ON 50/100/150/300/600/1,500-W Models A harmonic current suppression circuit is built into the input power. This circuit can create noise when the input is turned ON, but it will last only until internal operation stabilizes and does not indicate any problem in the Power Supply. DIN Rail Mounting 15/30/50/100/150/300/600-W Models When mounting to a DIN Rail, lower the S8VM onto the Rail until the Rail stopper clicks into place, hook section A over the edge of the Rail and push in the direction of B. (A) If there is no output voltage even after checking the following five points, please contact your OMRON representative. Check the overload protected status. Check whether the load is in overload status or is short-circuited. Remove the load wires when checking. (B) To remove the S8VM from the DIN Rail, insert a screwdriver into section C and pull the S8VM away from the Rail. Attempt to clear the overvoltage protection function. Turn OFF the input power once and leave it OFF for at least 3 minutes. Then turn it ON again to see if this clears the condition. Check whether the +S terminal and −S terminal are open. 30 mm min. (C) Rail stopper Check if the output voltage has been adjusted to more than +20% of the rated voltage using the output voltage adjuster (V. ADJ). 35 S8VM ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 36 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2010 All Right Reserved.