MEANWELL SBT01

SBT01
1W DC-DC Unregulated Single Output Converter
series
Features :
1000VDC I/O isolation
Internal SMD technology
Protection: Short circuit
Cooling by free air convection
Non-conductive plastic case
SMD package styles
100% full load burn-in test
Low cost / High reliability
Approved: UL / CUL
1 year warranty
SPECIFICATION
ORDER NO.
OUTPUT
SBT01L-05
SBT01L-09
SBT01M-05
SBT01M-09
9V
DC OUTPUT VOLTAGE
5V
OUTPUT CURRENT RANGE
0 ~ 200mA
EFFICIENCY
70%
RATED POWER
1W
SBT01L-12
SBT01M-12
12V
0 ~ 111mA
SBT01L-15
SBT01M-15
15V
0 ~ 84mA
0 ~ 67mA
74%
75%
74%
75%
75%
75%
10.8 ~ 13.2V
12V
4.5 ~ 5.5V
5V
10.8 ~ 13.2V
12V
4.5 ~ 5.5V
5V
10.8 ~ 13.2V
12V
4.5 ~ 5.5V
5V
10.8 ~ 13.2V
12V
120mA
292mA
120mA
292mA
120mA
292mA
120mA
15mA
29mA
15mA
29mA
15mA
29mA
15mA
72%
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION
Note.3 1.2% for 1% input variation
LOAD REGULATION
Note.4 8.0%
VOLTAGE TOLERANCE
8.0%
SWITCHING FREQUENCY(Typ.) 100KHz
4.5 ~ 5.5V
5V
VOLTAGE RANGE
NORMAL VOLTAGE
Full load 292mA
No load 29mA
INPUT CURRENT
Fuse recommended
PROTECTION
Momentary
OVERLOAD
Protection type : Broken
Momentary
PROTECTION
SHORT CIRCUIT
Protection type : Broken
WORKING TEMP.
-40 ~ +85
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
MTBF
OTHERS
DIMENSION
-40 ~ +105
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25
Unit: mm (inch)
12.7
7.62
1
2.54
2
3
6.00
TOP VIEW
4.13
5
6.25
7.50
11.2 MAX
6
/ 70% RH
500khrs min. MIL-HDBK-217F(25 )
12.7*7.5*6.0mm or 0.50"*0.30"*0.24" inch (L*W*H)
Mechanical Specification
7
, 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2
1.3g
WEIGHT
8
(Refer to output load derating curve)
2.54
4
0.5
0.25
Derating Curve
Pin Configuration
Pin No.
Output
1
2
3
4
5
6
7
8
-Vin
+Vin
NC
-Vout
+Vout
NC
NC
NC
100
LOAD (%)
INPUT
80
-40
NOTE
0
25
50 70 85
100
Ta (
)
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
File Name: SBT01-SPEC 2008-05-08