Preliminary SCA103T Series Inclinometer FEATURES • High sensitivity by differential analog output or digital output via SPI. Single ended signal available by using a differential amplifier or digitally using internal 11 bit digital output and external micro controller. • Available ranges ±15°,±30° • Over damped frequency response (-3dB @ 8...28 Hz) • Integrated temperature sensor, accessible via SPI • Digitally activated electrostatic sensing element self test • Continuous memory parity check • Advanced internal and external connection failure detection • Single +5V supply; ratiometric analog voltage outputs • Serial Peripheral Interface (SPI) compatible digital output • DIL-12 plastic SMD package, lead-free reflow solderable BENEFITS • High immunity to external interference and noise supply voltage. • Improved temperature dependency and long term stability • Excellent reliability and stability over time and temperature • Instrumentation grade performance • High resolution and low noise • Wide operating temperature range • Outstanding overload and shock durability APPLICATIONS • Single axis inclination instruments • Inclination based position measurement ELECTRICAL CHARACTERISTICS Electrical characteristics Condition Min Typ Max 4.75 5.0 5.25 V 4 5 mA Supply voltage Vdd (1 Current consumption Vdd = 5 V; No load Analog resistive output load Vout to Vdd or Vss 10 kOhm Analog capacitive output load 20 Digital output load @ 500kHz clock SPI clock frequency AD conversion time Data transfer time @500 kHz clock Units nF 1 nF 500 kHz 150 µs 38 µs PERFORMANCE CHARACTERISTICS D/S Performance characteristics Condition D Measuring range (2 Nominal D Measuring direction (3 Mounting plane horizontal S Zero point (4 Mounting position D Sensitivity @ room temperature S Offset calibration accuracy (6a, 13 D Offset temperature dependency @ room temperature (6b, 13 D 0...70°C -25…85°C D -40…125°C SCA103T-D04 SCA103T-D05 Units ±15 ±0.26 Horizontal ±30 ±0.5 Horizontal ° g Vdd/2 280(15 16(5a 0.057 ±1 < ± 0.11 < ±2 < ±0.14 < ±2.5 < ±0.29 < ±5 ±0.5 Vdd/2 140(15 8(5b 0.11 ±2 < ±0.11 < ±2 < ±0.14 < ±2.5 < ±0.29 < ±5 ±0.5 V mV/° V/g ° mg ° mg ° mg ° mg % S Sensitivity calibration accuracy (7a, 13 @ room temperature D Sensitivity temperature error (7b, 13 -40...85°C -1…1 -1…1 % -40…125°C -2.5…1 ±0.11 ±2 4 % ° mg % Hz D D Typical non-linearity (8 Over measuring range S Cross-axis sensitivity (11 @ room temperature -2.5…1 ±T.B.D ±T.B.D 4 S Frequency response –3dB (LP) (9 @ room temperature 8…28 8…28 S Ratiometric error Vdd = 4.75...5.25V 1 1 % D Output noise density (12 From DC...100Hz D Digital output resolution Effective Differential D Long term stability (14 @ steady temp 0.0004 0.009 12 < 0.014 0.0004 0.017 12 < 0.014 °/√Hz °/LSB Bits ° (10 Parameters marked as D are measured in differential mode using external differential amplifier. The performance of selected amplifier may have an effect to some parameters. Differential signal is determined as a Out_diff = Out_1 – Out_2 (pin 11 – pin 5). VDD = 5.00 V, APPLIES TO BOTH CHANNELS UNLESS OTHERWISE SPECIFIED Note 1. Note 2. Note 3. Note 4. Note 5a. Note 5b. Note 6a. Note 6b. Note 7a. Note 7b. Rev. 6 Apr 2005 For maximum accuracy the supply voltage should be 5 ± 0.05 V. 100nF supply filtering capacitor should be used. The measuring range is limited by sensitivity, offset and supply voltage rails of the device. Measuring direction parallel to mounting plane, arrow showing positive direction. Offset specified as Voffset = Vout(0g) [ V ]. See note 12. Sensitivity specified as Vsens = {Vout(+0.26g) - Vout(-0.26g)}/0.52 [ V/g ]. See note 12 Sensitivity specified as Vsens = {Vout(+0.5g) - Vout(-0.5g)}/1 [ V/g ]. See note 12 Offset calibration error specified as Offset_Calib_error = {Vout(0g) – Vdd/2} / Vsens [ g ]. Offset temperature error specified as Offset Error @ temp. = {Vout @ temp. – Vout @ room temp.} / Vsens [ g ] Vsens = Nominal sensitivity. See note 12. Sensitivity calibration error specified as Sensitivity_calibr_error = { Vsens - Vsens_nom} / Vsens_nom x 100% [%] Vsens_nom = nominal sensitivity Sensitivity temperature error specified as Sensitivity error @ temp = { [Vsens @ temp –Vsens @ room temp] / Vsens @ room temp x 100% [ % ]. See note 12. VTI Technologies reserves the right to modify this specification without prior to notice. Note 8. Note 9. From straight line through sensitivity calibration points. The output has true DC (0Hz) response. Note 10. The ratiometric error is specified as: Note 11. The cross-axis sensitivity determines how much inclination / acceleration, perpendicular to the measuring axis, couples to the output. The total cross-axis sensitivity is the geometric sum of the sensitivities of the two axis which are perpendicular to the measuring axis. In addition, supply voltage noise couples to the output due to the ratiometric nature of the accelerometer. Factory calibration value. Power continuously connected. Is valid between angles 0° to 1°. Note 12. Note 13. Note 14. Note 15. SCA103T Series ABSOLUTE MAXIMUM RATINGS Parameter Value Acceleration (powered or non powered) 20 000 Unit g Supply voltage -0.3 V to +5.5 V V Voltage at input/output pins -0.3 V to (Vdd+0.3V) V Temperature range -55…125 °C ELECTRICAL CONNECTION Pin# Pin Name I/O Connection 1 SCK Input Serial clock 2 Ext_C_1 Input Channel 1 external capacitor input 3 MISO Output Master in slave out; data output 4 MOSI Input Master out slave in; data input 5 Out_2 Output Channel 2 output 6 VSS Power Negative supply voltage (VSS) 7 CSB Input Chip select (active low) 8 Ext_C_2 Input Channel 2 external capacitor input 9 ST_2 Input Self test input for Channel 2 10 ST_1 Input Self test input for Channel 1 11 Out_1 Output Channel 1 output 12 VDD Power Positive supply voltage (VDD) If The SPI interface is not used SCK (pin1), MISO (pin3), MOSI (pin4) and CSB (pin7) must be left floating. Self test can be activated applying logic “1” (positive supply voltage level) to ST pins (pins 9 & 10). If ST feature is not used, then pins 9 & 10 must be left floating or connected to GND. DIMENSIONS PCB PAD LAYOUTS The part weights < 1.2 g. The size is approximately 9 x 5 x 16 mm (w x h x l). Pin pitch is standard 100 mils. 103T APPLICATION EXAMPLE Single ended output can be formed from differential outputs by using external differential amplifier. Typical output characteristics +5V +15V 5,0000 4,0000 Out 2 100nF Out 1 3,0000 Outputs [V] 2,0000 SCA103T 1,0000 0,0000 1 2 3 4 OUT 2 5 6 Differential output -1,0000 -2,0000 -3,0000 -4,0000 -5,0000 -40 -30 -20 -10 0 10 20 30 40 Angle [°] VTI Technologies Oy Myllynkivenkuja 6 P.O. Box 27 FI-01621 Vantaa Finland Tel. +358 9 879181 Fax +358 9 87918791 sales@vti.fi VTI Technologies Oy Frankfurt Branch Rennbahnstr. 72-74 D-60528 Frankfurt am Main Germany Tel. +49 69 6786 880 Fax +49 69 6786 8829 sales.de@vti.fi VTI Technologies, Inc. One Park Lane Blvd. Suite 804 - East Tower Dearborn, MI 48126 USA Tel. +1 313 425 0850 Fax +1 313 425 0860 [email protected] 12 11 OUT 1 10 9 100nF 8 7 5k11 71 5 INA114 2 – 6 5k11 3 + A1 4 8 10n 10n OUTPUT 100nF −15V