celduc® r e l a i S/CON/SCI0100600/B/07/03/07 s PRELIMINARY DATA Page 1/5 UK IGBT BASED DC SOLID-STATE RELAY SCI0100600 X Latest high voltage IGBT technology generation. X New innovative isolated driver ensuring fast power transistor turn on and off therefore low power transient. X Ultra low output leakage current Control voltage range Max transient peak voltage Advised max. DC Mains peak voltage Max. Load Current (with heatsink) X Low control current consumption X Triggered control input to avoid linear control risks X Low conducted and radiated disturbances DC Mains voltage range Load current range 350VDC Max Advised (Depends on protection clamping voltage) (with heatsink) Fig. 1 0 to 100A Control input voltage range In & case / Out Insulation Connections 4.5-32VDC 4kV M3 round tabs M5 round tabs HIGH SIDE WIRING DIAGRAM (Load connected to “-“) 4.5-32VDC 600V 350VDC 100ADC Dimensions (WxHxD) Weight 44.5 x 58.2 x 27 100g (mm) LOW SIDE WIRING DIAGRAM (Load connected to “+”) Fig. 2 Please consult us to select the right protective components C1, D1 & D2. Please consult us to select the right protective components C1, D1 & D2. The red paths (C1/D1/D2) must be as short as possible ! The red paths (C1/D1/D2) must be as short as possible ! Fig. 3 Proud to serve you Data given at Tambient=25°C and subject to modification without previous notice INTERNAL DIAGRAM celduc ® r e l a i s celduc® r e l a i S/CON/SCI0100600/B/07/03/07 s PRELIMINARY DATA Page 2/5 UK CONTROL INPUT CHARACTERISTICS INPUT CIRCUIT CHARACTERISTIC LABEL VALUE Nom. Control voltage Ucnom 12-24VDC Nom. Control current Control voltage range Control current consumption Releasing control voltage Icnom Uc 35mADC 4.5 – 32VDC typical=4.3V Ic 25 – 42mADC See curve Ucoffmax 1VDC Typical= 3.5V -Ucmax 32VDC -Icmax <100µA Rin Current limitation Max. reverse control voltage INFO. CONTROL CURRENT vs. CONTROL VOLTAGE Fig. 4 Ic (mADC) 45 40 35 @25°C 30 25 20 15 10 5 0 Input impedance 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 See curve Uc (VDC) TIME CHARACTERISTICS TIME CHARACT. CHARACTERISTIC LABEL VALUE Turn on time ton 10µs Turn on delay tdon 600µs Turn off time toff 10µs Turn off delay Max. On-Off frequency tdoff 100µs F(on-off) 700Hz POWER OUTPUT CHARACTERISTICS CHARACTERISTIC POWER CIRCUIT Mains voltage range LABEL Ut Ue VALUE INFO. Min = VCEsat Max (Advised) = 350VDC Depends on protection clamping voltage (D1) Non-repetitive peak voltage Utp 600V Overvoltage protection D1 Not integrated A voltage clamping mean must be connected across the terminals 1 & 2 (see fig 1 & 2) Please consult us to select the right protective components Off-state max reverse voltage drop (internal diode) -Ut 1.4V @Ie=100A Maximum nominal currents Ie max Max. non-repetitive peak current Iepeak Min. load current Iemin Max. leakage current Resistive Motor 100A Please contact us Switch OFF D<1% Switch OFF Fmax ON-state 100A 100A 550A See fig. 9 @Tc=100°C @Tj=175°C @Utp (See fig. 8) 0mA Ielk max 1mA VCEsat Typ. output capacitance Cout 300pF Junction/case thermal resistance Rthjc 0.385K/W Built-in heatsink thermal resistance vertically mounted Rthra 10K/W @∆Tra=75°C Heatsink thermal time constant Tthra 10 minutes @∆Tra=60°C Control inputs/power outputs insulation voltage Uimp 4kV Inputs/case insulation voltage Uimp 4kV Outputs/case insulation voltage Uimp 4kV Rio 1GΩ Isolation resistance Isolation capacitance Maximum junction temperature Storage ambient temperature Operating ambient temperature Max. case temperature 1.35V @Tj=25°C @Utp @Tjmax Max. on-state resistance 1.45V @Tj=125°C Cio <8pF Tjmax 175°C Tstg -40->+100°C Tamb -40->+90°C Tc 100°C @Iemax @Utp See fig. 9 celduc® r e l a i S/CON/SCI0100600/B/07/03/07 s PRELIMINARY DATA Page 3/5 UK OUTPUT SWITCH CHARACTERISTIC CURVES Fig. 5 VOLTAGE DROP VS LOAD CURRENT REVERSE VOLTAGE DROP VS REVERSE CURRENT Fig. 6 140 Ie (A) -Ie (A) 200 120 100 150 80 100 Tj = 25°C 60 Tj=125°C Tj = 125°C 40 Tj = 175°C 20 50 -Ut (V) VCEsat (V) 0 0 0 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 0 POWER ELEMENT TRANSIENT THERMAL IMPEDANCE vs. PULSE DURATION Fig. 7 0,18 0,2 0,5 1 1,5 2 ON-STATE PEAK OVERLOAD CURRENT vs. PULSE DURATION Fig. 8 700 Zthjc (K/W) Ie (Apk) 0,16 600 0,14 Non-repetitive D=1% (Tc=100°C, Tjm ax=175°C) 500 0,12 0,1 D=50% 0,08 D=20% 400 300 D=10% 0,06 200 D=5% 0,04 D=2% 0,02 D=1% 100 Repetitive D=50%(Tc=100°C, Tjmax=125°C) 0 0,0001 Single pulse 0 0,0001 0,001 0,01 Fig. 9 0,1 t (s) 0,001 0,1 Pulse 1 Duration (s) 0,01 1 POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE Permanent current Ie (ARMS) Power dissipated Pd (W) Please refer to the installation notice for precautions about mounting the device on a heatsink. 160 110 2.2K/W 2.1K/W 1.2K/W 1.1K/W 0.9K/W 0.75K/W 0.55K/W 0.3K/W 0.2K/W 0.1K/W 100 145 90 131 80 116 70 102 60 87 50 72.5 40 58 30 43.5 20 29 10 14.5 8K/W 0 0 4K/W 10 0 20 30 40 50 60 10K/W = No Heatsink / 1LD12020 4K/W = 150x150x3mm aluminium sheet 2.1K/W = WF210000 1.2K/W = WF121000 1.1K/W = WF131100 0.55K/W = WF050000 0.3K/W = WF031100 0.2K/W = No reference 70 80 90 100 110 Ambient temperature (°C) 2.2K/W = WF262100 / WF151200 0.9K/W = WF115100 0.75K/W = WF070000 0.1K/W = No reference celduc® r e l a i S/CON/SCI0100600/B/07/03/07 s PRELIMINARY DATA Page 4/5 UK MISC. CONNECTIONS GENERAL INFORMATION Connections Power Control Philips™ NR2 Philips™ NR1 1.8 N.m 0.8 N.m Insulated crimp terminals (round tabs, eyelet type) M5 M3 Display Green LED (indicates relay has switched ON) Housing UL94V0 Screwdriver advised Min and max tightening torque Mounting 2 screws (M4x12mm) Noise level No audible noise Weight See mounting sheet 100g E.M.C. EMISSION E.M.C. IMMUNITY GENERAL STANDARDS Standards IEC60947-1 Protection level IP00 Protection against direct touch None CE marking Yes UL, cULUS and VDE approvals Pending TYPE OF TEST STANDARD LEVEL EFFECT E.S.D. (Electrostatic discharges) EN61000-4-2 Pending ? Radiated electromagnetic fields EN61000-4-3 Pending ? Fast transients bursts EN61000-4-4 Pending No effect Electric chocks EN61000-4-5 Pending ? Voltage drop EN61000-4-11 - Radiated and conducted disturbances NFEN55011 Pending celduc® r e l a i S/CON/SCI0100600/B/07/03/07 s PRELIMINARY DATA Page 5/5 UK DIMENSIONS AND ACCESSORIES Fig. 10 DIMENSIONS (mm) 28 ±0,5 22.8 28 Ø4.7 M5 2- 4- 3+ 47.6 1+ 25.4 25.8 44.5 5.1 7.5 43.2 58.2 19.6 M3 TOLERANCES: ± 0.3 ACCESSORIES PROTECTIVE COVER 1K470000 Please consult our website for other accessory references (Heatsinks, mounting adaptors, thermal grease…) celduc® r e l a i s www.celduc.com Rue Ampère B.P. 4 42290 SORBIERS - France Phone : 33 (0) 4 77 53 90 20 Fax : 33 (0) 4 77 53 85 51 Email : [email protected]