SE-600 600W Single Output Power Supply series Features : AC input active surge current limiting AC input range selected by switch Protections:Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan High power density 4.9w/in3 Built-in remote sense function UL approved Low cost 2 years warranty SPECIFICATION MODEL OUTPUT SE-600-5 SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-36 SE-600-48 DC VOLTAGE 5V 12V 15V 24V 27V 36V 48V RATED CURRENT 100A 50A 40A 25A 22.2A 16.6A 12.5A CURRENT RANGE 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 25A 0 ~ 22.2A 0 ~ 16.6A 0 ~ 12.5A RATED POWER 500W 600W 600W 600W 599.4W 597.6W 600W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p VOLTAGE ADJ. RANGE 10 ~ 13.5V 13.5 ~ 16.5V 22 ~ 26.4V VOLTAGE TOLERANCE Note.3 INPUT 32 ~ 40V 43 ~ 56V 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 20ms/230VAC VOLTAGE RANGE FREQUENCY RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch 47 ~ 63Hz EFFICIENCY (Typ.) AC CURRENT (Typ.) 12A/115VAC 78% 1000ms, 50ms/115VAC at full load 16ms/115VAC at full load 83% 254 ~ 370VDC 84% 87% 87% 87% 88% 7.5A/230VAC LEAKAGE CURRENT 25A/115VAC 50A/230VAC <2.0mA / 240VAC OVERLOAD 105 ~ 125% rated output power Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 5.75 ~ 6.3V 13.8 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 42 ~ 50V Protection type : Shut down o/p voltage, re-power on to recover 85 5 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -20 ~ +60 WORKING HUMIDITY 20 ~ 90% RH non-condensing PROTECTION OVER VOLTAGE ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE MTBF DIMENSION PACKING NOTE 24 ~ 30V 1.0% LINE REGULATION INRUSH CURRENT (Typ.) OTHERS 4.75 ~ 5.5V 2.0% -40 ~ +85 57.6 ~ 67.2V (Refer to output load derating curve) , 10 ~ 95% RH 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 197K hrs min. MIL-HDBK-217F (25 247*127*63.5mm (L*W*H) 2.1Kg; 6pcs/13.4Kg/1.03CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. File Name:SE-600-SPEC 2008-04-10 SE-600 600W Single Output Power Supply Mechanical Specification Case No. 926A 14 max. 20 63.5 30 8.2 1 2 I/P 3 127 1 2 3 O/P 4 5 6 CN4 RS + Air flow direction 13 220 247 10 11 10 Unit:mm 17 max. 4-M3 L=4 230/115VAC series +Adj. RS +- 16 220 20 30 4-M3 L=4 AC input terminal : Pin No. 1 2 3 DC Output terminal : Assignment AC/L AC/N FG Pin No. 1~3 4~6 RS Connector (CN4) : JST B-XH or equivalent Assignment +V -V Pin No. 1 2 Assignment +S -S Mating Housing JST XHP or equivalent Terminal JST SXH-001T or equivalent Block Diagram fosc : 68KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT FG O.L.P. O.T.P. PWM CONTROL Derating Curve +V -V O.V.P. Static Characteristics 100 100 Other 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 5V 60 50 40 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 90 180 95 190 100 200 115 230 130 260 INPUT VOLTAGE (VAC) 60Hz File Name:SE-600-SPEC 2008-04-10