INTEL SE7230CA1-E

Intel® Entry Server Board
SE7230CA1-E
Technical Product Specification
D59801-001
Revision 1.0
April 2006
Enterprise Platforms and Services Division
Revision History
Intel® Entry Server Board SE7230CA1-E TPS
Revision History
Date
April 2006
Revision
Number
0.5
Modifications
Release subject to change.
May 2006
1.0
Update bios.
Disclaimers
Information in this document is provided in connection with Intel® products. No license, express, implied,
by estoppel, or otherwise, to any intellectual property rights is granted by this document. Except as
provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever,
and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including
liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any
patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life
saving, or life sustaining applications. Intel may make changes to specifications and product descriptions
at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked reserved
or undefined. Intel reserves these for future definition and shall have no responsibility whatsoever for
conflicts or incompatibilities arising from future changes to them.
This document contains information on products in the design phase of development. Do not finalize a
design with this information. Revised information will be published when the product is available. Verify
with your local sales office that you have the latest datasheet before finalizing a design.
The Intel® Entry Server Board SE7230CA1-E may contain design defects or errors known as errata
which may cause the product to deviate from published specifications. Current characterized errata are
available on request.
This document and the software described in it are furnished under license and may only be used or
copied in accordance with the terms of the license. The information in this manual is furnished for
informational use only, is subject to change without notice, and should not be construed as a commitment
by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies
that may appear in this document or any software that may be provided in association with this document.
Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval
system, or transmitted in any form or by any means without the express written consent of Intel
Corporation.
Intel, Pentium®, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © Intel Corporation 2006.
ii
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Table of Contents
Table of Contents
1.
2.
Introduction .......................................................................................................................... 1
1.1
Section Outline ........................................................................................................ 1
1.2
Server Board Use Disclaimer .................................................................................. 1
Server Board Overview ........................................................................................................ 2
2.1
3.
Functional Architecture ....................................................................................................... 6
3.1
Processor Sub-System ............................................................................................ 7
3.1.1
Processor Voltage Regulator Down (VRD).............................................................. 8
3.1.2
Reset Configuration Logic ....................................................................................... 8
3.1.3
Processor Support ................................................................................................... 8
3.2
Intel® E7230 Chipset................................................................................................ 9
3.2.1
Intel® E7230 Chipset MCH: Memory Control Hub .................................................. 9
3.2.2
I/O Controller Hub.................................................................................................. 12
3.3
Memory Sub-System ............................................................................................. 14
3.3.1
Memory Configuration ........................................................................................... 14
3.3.2
Memory DIMM Support.......................................................................................... 16
3.4
I/O Sub-System ..................................................................................................... 16
3.4.1
PCI Subsystem ...................................................................................................... 16
3.4.2
Interrupt Routing .................................................................................................... 18
3.5
PCI Error Handling................................................................................................. 19
3.5.1
Video Support ........................................................................................................ 22
3.5.2
Network Interface Controller (NIC) ........................................................................ 22
3.5.3
Super I/O Chip ....................................................................................................... 23
3.5.4
BIOS Flash ............................................................................................................ 24
3.5.5
System Health Support.......................................................................................... 25
3.6
4.
Intel® Entry Server Board SE7230CA1-E Feature Set............................................ 2
Replacing the Back-Up Battery.............................................................................. 25
System BIOS ....................................................................................................................... 26
4.1
BIOS Setup Utility .................................................................................................. 26
4.1.1
Localization............................................................................................................ 26
4.1.2
Configuration Reset ............................................................................................... 26
4.1.3
Keyboard Commands ............................................................................................ 26
4.1.4
Entering BIOS Setup ............................................................................................. 27
Revision 1.0
iii
Table of Contents
4.1.5
4.2
4.2.2
O/S Present Flash Utility........................................................................................ 38
4.4
DMI/SMBIOS Support............................................................................................ 38
DMI/SMBIOS Write Tool ........................................................................................ 38
Operating System Boot, Sleep, and Wake ............................................................ 38
4.4.1
Boot Device Selection............................................................................................ 38
4.4.2
Operating System Support .................................................................................... 38
4.4.3
Front Control Panel Support .................................................................................. 40
4.4.4
Sleep and Wake Support....................................................................................... 40
Server Management ........................................................................................................... 41
5.1
Console Redirection .............................................................................................. 41
5.1.1
Serial Configuration Settings ................................................................................. 41
5.1.2
Keystroke Mappings .............................................................................................. 41
5.1.3
Limitations.............................................................................................................. 42
5.2
Intel® Active Management Technology (AMT) ....................................................... 42
5.3
Wired For Management (WFM) ............................................................................. 44
5.3.1
PXE BIOS Support ................................................................................................ 44
5.4
System Management BIOS (SMBIOS) .................................................................. 44
5.5
Security.................................................................................................................. 44
5.5.1
Operating Model .................................................................................................... 44
5.5.2
Password Protection.............................................................................................. 45
5.5.3
Password Clear Jumper ........................................................................................ 45
Error Reporting and Handling ........................................................................................... 46
6.1
Error Handling and Logging................................................................................... 46
6.1.1
Error Sources and Types....................................................................................... 46
6.1.2
Error Logging via SMI Handler .............................................................................. 47
6.1.3
SMBIOS Type 15 ................................................................................................... 47
6.1.4
Logging Format Conventions................................................................................. 47
6.2
iv
Flash Memory Update Utility.................................................................................. 37
BIOS Update.......................................................................................................... 37
4.3.1
6.
Operation ...............................................................................................................36
4.2.1
4.3
5.
Intel® Entry Server Board SE7230CA1-E TPS
Error Messages and Error Codes .......................................................................... 49
6.2.1
Diagnostic LEDs .................................................................................................... 49
6.2.2
POST Code Checkpoints....................................................................................... 50
6.2.3
POST Error Messages and Handling .................................................................... 53
6.2.4
POST Error Beep Codes ....................................................................................... 54
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
6.2.5
7.
7.1
Power Connectors ................................................................................................. 55
7.2
I2C Header ............................................................................................................. 55
7.3
Front Panel Connector........................................................................................... 56
7.4
I/O Connectors....................................................................................................... 56
7.4.1
VGA Connector...................................................................................................... 56
7.4.2
NIC Connectors ..................................................................................................... 57
7.4.3
SATA Connectors .................................................................................................. 57
7.4.4
Serial Port Connectors........................................................................................... 57
7.4.5
USB Connector...................................................................................................... 58
7.5
Fan Headers .......................................................................................................... 59
7.6
Miscellaneous Headers and Connectors ............................................................... 59
7.6.1
Chassis Intrusion Header ...................................................................................... 59
7.6.2
Back Panel I/O Connectors ................................................................................... 59
7.6.3
POST Code LEDs.................................................................................................. 60
7.7.1
Jumper Blocks ....................................................................................................... 60
Clear CMOS and System Maintenance Mode Jumpers ........................................ 60
Absolute Maximum Ratings .............................................................................................. 61
8.1
9.
POST Error Pause Option ..................................................................................... 54
Connectors and Jumper Blocks ....................................................................................... 55
7.7
8.
Table of Contents
Mean Time Between Failures (MTBF) Test Results .............................................. 61
Design and Environmental Specifications....................................................................... 62
9.1
Power Budget ........................................................................................................ 62
9.2
Product Regulatory Compliance ............................................................................ 62
9.2.1
Product Safety Compliance ................................................................................... 62
9.2.2
Product EMC Compliance – Class A Compliance ................................................. 63
9.2.3
Certifications / Registrations / Declarations ........................................................... 63
9.2.4
Product Regulatory Compliance Markings ............................................................ 64
9.3
Electromagnetic Compatibility Notices .................................................................. 64
9.3.1
Industry Canada (ICES-003) ................................................................................. 64
9.3.2
Europe (CE Declaration of Conformity) ................................................................. 65
9.3.3
Australia / New Zealand......................................................................................... 65
9.4
Restriction of Hazardous Substances (RoHS)....................................................... 65
9.5
Calculated Mean Time Between Failures (MTBF) ................................................. 65
9.6
Mechanical Specifications ..................................................................................... 65
10. Hardware Monitoring ......................................................................................................... 67
Revision 1.0
v
Table of Contents
10.1
10.1.1
10.2
Intel® Entry Server Board SE7230CA1-E TPS
Monitored Components..........................................................................................67
Fan Speed Control................................................................................................. 67
Chassis Intrusion ................................................................................................... 68
Glossary..................................................................................................................................... 69
References................................................................................................................................. 72
vi
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
List of Figures
List of Figures
Figure 1. Intel® Entry Server Board SE7230CA1-E Layout.......................................................... 4
Figure 2. Intel® Entry Server Board SE7230CA1-E Block Diagram ............................................. 6
Figure 3. Memory Bank Label Definition..................................................................................... 15
Figure 4. Interrupt Routing Diagram ........................................................................................... 20
Figure 5. Intel® ICH7R Interrupt Routing Diagram ..................................................................... 21
Figure 6. Location of Diagnostic LEDs on Server Board ............................................................ 50
Figure 7. Back Panel I/O Connections (not to scale) .................................................................. 59
Figure 8. Intel® Entry Server Board SE7230CA1-E Mechanical Drawing .................................. 66
Figure 9. Fan Speed Control Block Diagram .............................................................................. 67
Revision 1.0
vii
List of Tables
Intel® Entry Server Board SE7230CA1-E TPS
List of Tables
Table 1. Server Board Layout Reference ..................................................................................... 5
Table 2. Processor Support Matrix ............................................................................................... 9
Table 3. Supported DDR2 Modules ............................................................................................ 11
Table 4. Segment B Configuration.............................................................................................. 11
Table 5. Segment B Arbitration Connections.............................................................................. 11
Table 6. Memory Bank Labels and DIMM Population Order....................................................... 15
Table 7. Characteristics of Dual/Single Channel Configuration with or without Dynamic Mode . 16
Table 8. PCI Bus Segment Characteristics................................................................................. 17
Table 9. Segment A Configuration IDs ....................................................................................... 17
Table 10. Segment A Arbitration Connections............................................................................ 17
Table 11. PCI Interrupt Routing/Sharing..................................................................................... 18
Table 12. Interrupt Definitions..................................................................................................... 19
Table 13. Video Modes ............................................................................................................... 22
Table 14. Intel® 82573E (NIC 1 and NIC 2) ............................................................................... 23
Table 15. Serial A Header Pin-out .............................................................................................. 24
Table 16. Serial B Header Pin-out .............................................................................................. 24
Table 17. BIOS Setup Keyboard Command Bar Options ........................................................... 26
Table 18. BIOS Setup, Main Menu Options ................................................................................ 28
Table 19. BIOS Setup, Additional System Information Sub-menu Selections ............................ 28
Table 20. BIOS Setup, Advanced Menu Options........................................................................ 29
Table 21. BIOS Setup, Advanced Menu, Boot Configuration Sub-menu Selections .................. 29
Table 22. BIOS Setup, Advanced Menu, Peripheral Configuration Sub-menu........................... 30
Table 23. BIOS Setup, Advanced Menu, Drive Configuration Menu Options ............................. 30
Table 24. BIOS Setup, Advanced Menu, Event Log Configuration Sub-menu Selections ......... 31
Table 25. BIOS Setup, Advanced Menu, Video Configuration Sub-menu Selections ................ 31
Table 26. BIOS Setup, Advanced Menu, Hardware Monitoring Sub-menu Selections............... 32
Table 27. BIOS Setup, Advanced Menu, Chipset Configuration Sub-menu Selections ............. 32
Table 28. BIOS Setup, Advanced Menu, Chipset Configuration, Memory Configuration Submenu Selections................................................................................................................... 33
Table 29. BIOS Setup, Advanced Menu, Chipset Configuration, PCI Express* Configuration
Sub-menu Selections ........................................................................................................... 33
Table 30. BIOS Setup, Advanced Menu, Management Configuration Sub-menu Selections..... 33
viii
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
List of Tables
Table 31. BIOS Setup, Advanced Menu, USB Mass Storage Device Configuration Sub-menu
Selections............................................................................................................................. 34
Table 32. BIOS Setup, Security Menu Options........................................................................... 34
Table 33. BIOS Setup, Power Menu Selections ......................................................................... 34
Table 34. BIOS Setup, Boot Menu Selections ............................................................................ 35
Table 35. BIOS Setup, Exit Menu Selections ............................................................................. 35
Table 36. BIOS Setup Page Layout............................................................................................ 36
Table 37. Console Redirection Escape Sequences for Headless Operation.............................. 42
Table 38. Function List................................................................................................................ 44
Table 39. Security Features Operating Model ............................................................................ 45
Table 40. Event List .................................................................................................................... 46
Table 41. Logging Format Conventions...................................................................................... 48
Table 42. Event Type Definition Table........................................................................................ 48
Table 43. POST Progress Code LED Example .......................................................................... 50
Table 44. POST Code Checkpoints............................................................................................ 50
Table 45. POST Error Messages and Handling.......................................................................... 54
Table 46. POST Error Beep Codes ............................................................................................ 54
Table 47. Power Connector Pin-out (J3K1) ................................................................................ 55
Table 48. HSBP Header Pin-out (J1C1) ..................................................................................... 55
Table 49. Front Panel 14-pin Header Pin-out (J4k2) .................................................................. 56
Table 50. VGA Connector Pin-out (J3A1)................................................................................... 56
Table 51. NIC1-Intel® 82573E (10/100/1000) Connector Pin-out (JA5A1) ................................ 57
Table 52. NIC2- Intel® 82541PI (10/100/1000) Connector Pin-out (JA4A1) .............................. 57
Table 53. SATA Connector Pin-out (J5C1, J5C2) ...................................................................... 57
Table 54. External DB9 Serial A Port Pin-out (J3A1).................................................................. 58
Table 55. Internal 9-pin Serial B Port Pin-out (J1C2).................................................................. 58
Table 56. USB Connectors Pin-out (JA5A1)............................................................................... 58
Table 57. Optional USB Connection Header Pin-out (J9F2) ...................................................... 58
Table 58. Four-pin Fan Headers Pin-out (J3K2, J4K1).............................................................. 59
Table 59. Intrusion Cable Connector (J3B2) Pin-out ................................................................. 59
Table 60. System Maintenance Mode (J1A3)............................................................................. 60
Table 61. Clear CMOS Jumper Options (J3B2).......................................................................... 60
Table 62. Absolute Maximum Ratings ........................................................................................ 61
Table 63. The Board Power Budget............................................................................................ 62
Table 64. Product Certification Markings .................................................................................... 64
Revision 1.0
ix
List of Tables
Intel® Entry Server Board SE7230CA1-E TPS
Table 65. MTBF Data..................................................................................................................65
Table 66. Monitored Components............................................................................................... 67
x
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
1.
Introduction
Introduction
This Intel® Entry Server Board SE7230CA1-E Technical Product Specification (TPS) provides a
high-level technical description for the Intel® Entry Server Board SE7230CA1-E. It details the
architecture and feature set for all functional sub-systems that make up the server board.
1.1
Section Outline
This document is divided into the following chapters:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
1.2
Section 1 – Introduction
Section 2 – Server Board Overview
Section 3 – Functional Architecture
Section 4 – System BIOS
Section 5 – Platform Management Architecture
Section 6 – Error Reporting and Handling
Section 7 – Connectors and Jumper Blocks
Section 8 – Absolute Maximum Ratings
Section 9 – Design and Environmental Specifications
Section 10 – Hardware Monitoring
Appendix A – Integration and Usage Tips
Glossary
Reference Documents
Server Board Use Disclaimer
Intel® server boards contain a number of high-density VLSI* and power delivery components
that need adequate airflow to cool. Intel’s own chassis are designed and tested to meet the
intended thermal requirements of these components when the fully integrated system is used
together. It is the responsibility of the system integrator that chooses not to use Intel developed
server building blocks to consult vendor datasheets and operating parameters to determine the
amount of airflow required for their specific application and environmental conditions. Intel
Corporation cannot be held responsible if components fail or the server board does not operate
correctly when used outside any of its published operating or non-operating limits.
Revision 1.0
1
Server Board Overview
2.
Intel® Entry Server Board SE7230CA1-E TPS
Server Board Overview
The Intel® Entry Server Board SE7230CA1-E is a monolithic printed circuit board with features
that support the UP server high-density (1U) market.
2.1
Intel® Entry Server Board SE7230CA1-E Feature Set
The Intel® Entry Server Board SE7230CA1-E supports the following feature set:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
2
Processor and Front Side Bus (FSB) support
- Supports Pentium® 4 processor Extreme Edition, Pentium® processor Extreme
Edition, Pentium® D, Pentium® 4 and Celeron® D processors in the Intel® 775-pin
PLGA package
- Supports Intel® Dual Core Architecture
- Supports Hyper-Threading Technology
- Supports Intel® Extended Memory System 64 Technology (Intel® EM64T)
Intel® E7230 Chipset components
- Intel® E7230 MCH Memory Controller Hub
- Intel® ICH7R I/O Controller
- 12-deep In-order Queue
Memory System
- Four DIMM sockets supporting 533/667MHz DDR2 DIMMs
- Data bandwidth per channel of 4.2GB/s or 8.4GB/s in dual channel when using
DDR2 667MHz
- Support for up to two DDR2 channels for a total of four DIMMs (two DIMMs /
channel) providing up to 8 MB max memory capacity.
- Support for 512-MB, 1-GB and 2-GB DDR2 DIMMs
I/O Subsystem
Board I/O Subsystem (Two independent PCI buses):
- Segment A: One embedded Intel® Gigabit Ethernet Controller 10/100/1000 82541PI
(Supports PCI Specification, Rev 2.3)
- Segment B: One x1 PCI Express* resource implemented as an embedded Intel®
10/100/1000 82573E Gigabit Ethernet Controller
Serial ATA host controller
Two independent SATA ports support data transfer rates up to 1.5 Gb/s (150MB/s) per
port
Universal Serial Bus 2.0 (USB)
Two external USB ports with an additional internal header providing two optional USB
ports for front panel support.
- Supports wake-up from sleeping states S1-S4 (S3 not supported)
- Supports Legacy Keyboard/Mouse connections when using PS2-USB dongle
LPC (Low Pin Count) bus segment with one embedded device
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Server Board Overview
-
ƒ
ƒ
ƒ
Super I/O controller chips providing all PC-compatible I/O (floppy, serial, keyboard,
mouse, two serial com port ) and integrated hardware monitoring
- LC Super I/O = SMsC* LP47M182NR
Standard Intel® 14-pin SSI front panel 2x9 power connectors
Fan Support
- Two general purpose 4-pin fans
Intel® Light-guided Diagnostic LEDs to display POST code indicators during boot
Revision 1.0
3
Server Board Overview
Intel® Entry Server Board SE7230CA1-E TPS
The following figure shows the board layout of the Intel® Entry Server Board SE7230CA1-E.
Each connector and major component is identified by letter and is identified in Table 1.
Figure 1. Intel® Entry Server Board SE7230CA1-E Layout
4
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Server Board Overview
Table 1. Server Board Layout Reference
A
Ref
Post LEDs
Description
Ref
Q
Description
NIC1 SPI Flash
B
BIOS recovery jumper
R
Intel® 82541PI LAN Controller
C
BIOS Flash(FWH)
S
NIC2 SPI EEPROM
D
ATI* ES1000 video controller
T
Intel® AMT firmware update jumper
E
Chassis intrusion header
U
Intel® 82573E LAN Controller
F
Battery
V
USB 3 and 4 header
G
I2C Connector
W
Clear CMOS jumper
H
Serial B header
X
SATA port 2
I
SMSC* LPC47M182 SIO
Y
SATA port 1
J
Memory Slot DIMM 1A
Z
Intel® 82802 ICH7R
K
Memory Slot DIMM 2A
AA
Intel® E7230 MCH
L
Memory Slot DIMM 1B
BB
775-Land (LGA) CPU Socket
M
Memory Slot DIMM 2B
CC
System Fan 1 (4-pin)
N
2 x 9 Power connector
DD
System Fan 2 (4-pin)
O
NIC1 RJ-45 and USB 1 and 2 connector
EE
2 x 7 Front Panel header
P
NIC2 RJ-45 connector
FF
Hardware Management Controller
Revision 1.0
5
Functional Architecture
3.
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
This section provides a high-level description of the functionality associated with the
architectural blocks that make up the Intel® Entry Server Board SE7230CA1-E.
Figure 2. Intel® Entry Server Board SE7230CA1-E Block Diagram
6
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
3.1
Functional Architecture
Processor Sub-System
The Intel® Entry Server Board SE7230CA1-E supports the following:
ƒ
ƒ
ƒ
ƒ
ƒ
Pentium® 4 processor Extreme Edition in the 775-land package
Pentium® processor Extreme Edition in the 775-land package
Pentium® D processors in the 775-land package
Pentium® 4 processors in the 775-land package
Celeron® D processors in the 775-land package
The 775-land package is a follow-on to Pentium® 4 and Celeron® processors in the 478-pin
package with enhancements to the Intel NetBurst® micro-architecture, including but not limited
to the following:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Dual Core Architecture
Hyper-Threading Technology
Intel® EM64T
Pentium® 4 processor Extreme Edition
Pentium® processor Extreme Edition
Pentium® D processor
Pentium® 4 processor
Celeron® D processor
The processors built on 90-nm and 65-nm process technology in the 775-land package utilize
Flip-Chip Land Grid Array (FC-LGA4) package technology, and plug into a 775-land LGA
socket, referred to as the Intel® LGA775 socket. The processors are as follows:
ƒ
ƒ
ƒ
ƒ
Pentium® 4 processor Extreme Edition, Pentium® processor Extreme Edition
Pentium® D processor
Pentium® 4 Processor
Celeron® D Processor
The above processors in the 775-land package, like their predecessors in the 478-pin package,
are based on the same Pentium® 4 micro-architecture. They maintain compatibility with 32-bit
software written for the IA-32 instruction set, while supporting 64-bit native mode operation
when coupled with supported 64-bit operating systems and applications.
The Celeron® processor does not come in a dual-core configuration, or support HyperThreading Technology or Intel® EM64T.
Revision 1.0
7
Functional Architecture
3.1.1
Intel® Entry Server Board SE7230CA1-E TPS
Processor Voltage Regulator Down (VRD)
The Intel® Entry Server Board SE7230CA1-E has a VRD (Voltage Regulator Down) to support
one processor. It is compliant with the VRM 10.1 DC-DC Converter Design Guide Line and
provides a maximum of 120A, which is capable of supporting the requirements for the following
processors:
ƒ
ƒ
ƒ
ƒ
ƒ
Pentium® 4 processor Extreme Edition
Pentium® processor Extreme Edition
Pentium® D Processor
Pentium® 4 Processor
Celeron® D Processor
The board hardware monitors the processor VTTEN (Output enable for VTT) pin before turning
on the VRD. If the VTTEN pin of the processors is not identical, the Power On Logic will not turn
on the VRD.
3.1.2
Reset Configuration Logic
The BIOS determines the processor stepping, cache size, etc., through the CPUID instruction.
The requirement is:
ƒ
Processor run at a fixed speed, but BIOS can program it to operate at a lower or higher
speed.
The processor information is read at every system power-on.
Note: The processor speed is the processor power-on reset default value. No manual processor
speed setting options exist either in the form of a BIOS setup option or jumpers.
3.1.3
Processor Support
The Intel® Entry Server Board SE7230CA1-E supports one processor in the Intel® LGA775
package. The support circuitry on the server board consists of the following:
ƒ
ƒ
8
Intel® LGA775 processor socket supporting:
- Pentium® D Processor with 800MHz system bus
- Pentium® 4 Processor with 800MHz system bus
- Pentium® 4 processor Extreme Edition with 1066 MHz system bus
Processor host bus AGTL+ support circuitry
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Table 2. Processor Support Matrix
Processor Family
Package Type
Frequency
Cache Size
Front Side
Bus
Pentium® 4 processor
Extreme Edition
Intel® LGA775
3.73GHz
2MB L2
1066MHz
Pentium® D processor
Intel® LGA775
2.8 – 3.6GHz
2 x 1MB or 2x 2MB
L2
800MHz
Pentium® 4 processor
Intel® LGA775
3.2 – 3.8 GHz
1MB or 2MB L2
800MHz
Celeron® D processor
Intel® LGA775
2.26 – 3.2 GHz
256K L2
533MHz
Note: For a complete list of all supported processors, please visit the Intel® Entry Server Board
SE7230CA1-E support site located at the following URL:
http://support.intel.com/support/motherboards/server/
In addition to the circuitry described above, the processor subsystem contains the following:
ƒ
ƒ
3.2
Reset configuration logic
Server management registers and sensors
Intel® E7230 Chipset
The Intel® Entry Server Board SE7230CA1-E is designed around the Intel® E7230 Chipset.
The chipset provides an integrated I/O bridge and memory controller, and a flexible I/O
subsystem core (PCI Express*).
3.2.1
Intel® E7230 Chipset MCH: Memory Control Hub
The MCH accepts access requests from the host (processor) bus and directs those accesses to
memory or to one of the PCI buses. The MCH monitors the host bus, examining addresses for
each request. Accesses may be directed to the following:
ƒ
ƒ
A memory request queue for subsequent forwarding to the memory sub-system
An outbound request queue for subsequent forwarding to one of the PCI buses
The MCH also accepts inbound requests from the Intel® ICH7R. The MCH is responsible for
generating the appropriate controls to control data transfer to and from memory.
Revision 1.0
9
Functional Architecture
Intel® Entry Server Board SE7230CA1-E TPS
The MCH is a 1210-ball FC-BGA device and uses the proven components of the following
previous generations:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Pentium® 4 processor Extreme Edition
Pentium® processor Extreme Edition
Pentium® D Processor
Pentium® 4 Processor bus interface unit
Hub interface unit
DDR2 memory interface unit
The MCH also increases the main memory interface bandwidth and maximum memory
configuration with a 72-bit wide memory interface.
The MCH integrates the following main functions:
ƒ
ƒ
An integrated high performance main memory subsystem
A DMI which provides an interface to the Intel® ICH7R
Other features provided by the MCH include the following:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
3.2.1.1
Full support of ECC on the processor bus
Full support of Intel® x4 Single Device Data Correction on the memory interface with x4
DIMMs
Twelve deep in-order queue, two deep defer queue
Full support of un-buffered DDR2 ECC DIMMs
Support for 1 GB and 2 GB DDR2 memory modules
Memory scrubbing
MCH Memory Sub-System Overview
The MCH supports a 72-bit wide memory sub-system that can support a maximum of 8 GB of
DDR2 memory using 2 GB DIMMs. This configuration needs external registers for buffering the
memory address and control signals. The four chip selects are registered inside the MCH and
need no external registers for chip selects.
The memory interface runs at 533/667MT/s. The memory interface supports a 72-bit wide
memory array. It uses seventeen address lines (BA [2:0] and MA [13:0]) and supports 512-MB,
1-GB, and 2-GB DRAM densities. The DDR DIMM interface supports memory scrubbing, singlebit error correction, and multiple-bit error detection and Intel® x4 Single Device Data Correction
with x4 DIMMs.
The DDR2 interface supports up to 8 GB of main memory and supports single- and doubledensity DIMMs. The DDR2 can be any industry-standard DDR2. The following table shows the
DDR2 DIMM technology supported.
10
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Table 3. Supported DDR2 Modules
DIMM
Capacity
512 MB
DIMM
Organization
64M x 72
DDR2-533/667 Un-buffered
SDRAM Module Matrix
SDRAM
SDRAM
# SDRAM
# Address bits
Density
Organization Devices/rows/Banks
rows/Banks/column
256Mbit
32M x 8
18 / 2 / 4
13 / 2 / 10
512 MB
64M x 72
512Mbit
64M x 8
9/1/4
14 / 2 / 10
1 GB
128M x 72
512Mbit
64M x 8
18 / 2 / 4
14 / 2 / 10
1 GB
128M x 72
1Gbit
128M x 8
9/1/8
14 / 4 / 10
2 GB
256M x 72
2GB
128M x 8
18 / 2 / 8
14 / 8 / 10
3.2.1.2
PCI Express*
3.2.1.2.1
x1 PCI Express* Subsystem
The Intel® ICH7R supports two x 1 PCI Express* buses. Only one is used to support the Intel®
82573-Gigabit Ethernet Controller.
One 32-bit PCI bus segment is directed through the Intel® ICH7R Interface A. This PCI
Segment B has an embedded device, the Intel® 82541PI LAN (NIC2).
Each device under the PCI hub bridge has its IDSEL signal connected to one bit of AD [31:16],
which acts as a chip select on the PCI bus segment in configuration cycles. This determines a
unique PCI device ID value for use in configuration cycles. The following table shows the bit to
which each IDSEL signal is attached for P32-B devices and the corresponding device
description:
Table 4. Segment B Configuration
IDSEL Value
Device
21
Intel® 82541PI LAN (NIC2)
PCI Segment B supports one PCI master. All PCI masters must arbitrate for PCI access using
resources supplied by the Intel® ICH7R. The host bridge PCI interface arbitration lines REQx*
and GNTx* are internal to the Intel® ICH7R. The following table defines the arbitration
connections:
Table 5. Segment B Arbitration Connections
Server board Signals
PCIX REQ_N5/GNT_N5
Revision 1.0
Device
Intel® 82541PI LAN (NIC2)
11
Functional Architecture
3.2.2
3.2.2.1
Intel® Entry Server Board SE7230CA1-E TPS
I/O Controller Hub
Intel® ICH7R: I/O Controller Hub 7R
The Intel® ICH7R controller has several components. It provides the interface for a
32-bit/33-MHz PCI bus. The Intel® ICH7R can be both a master and a target on that PCI bus
and includes a USB 2.0 controller and an IDE controller. The ICH7R controller is also
responsible for much of the power management functions, with ACPI control registers built in. It
also provides a number of GPIO pins and has the LPC bus to support low-speed Legacy I/O.
The MCH and Intel® ICH7R chips provide the pathway between the processor and the I/O
systems. The MCH is responsible for accepting access requests from the host (processor) bus,
and directing all I/O accesses to one of the PCI buses or Legacy I/O locations. If the cycle is
directed to one of the PCI Express* segments, the MCH communicates with the PCI Express*
devices (add-in card, on board devices) through the PCI Express* interface. If the cycle is
directed to the Intel® ICH7R, the cycle is output on the MCH’s DMI bus. All I/O for the board,
including PCI and PC-compatible I/O, is directed through the MCH and then through the Intel®
ICH7R provided PCI buses.
The Intel® ICH7R is a multi-function device, housed in a 609-pin mBGA device. It provides the
following:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
A DMI bus
A PCI 32-bit/33-MHz interface
An IDE interface
An integrated Serial ATA Host controller
A USB controller
A PCI Express* x4 interface
A power management controller
Each function within the Intel® ICH7R has its own set of configuration registers. Once
configured, each appears to the system as a distinct hardware controller sharing the same PCI
bus interface.
The primary role of the ICH7R controller is providing the gateway to all PC-compatible I/O
devices and features. The board uses the following the Intel® ICH7R features:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
12
PCI 32-bit/33MHz interface for Intel® 82541PI Gigabit Ethernet Controller
PCI 32-bit/33MHz interface to dedicated ATI* ES1000 video subsystem
LPC bus interface
x1 PCI Express* interface for Intel® 82573E Gigabit Ethernet Controller
DMI (Direct Media Interface)
Integrated dual-port Serial ATA Host controller
Universal Serial Bus (USB) 2.0 interface
PC-compatible timer/counter and DMA controllers
APIC and 82C59 interrupt controller
Power management
System RTC
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
ƒ
ƒ
Functional Architecture
Supports the SmBUS 2.0 Specification
General-purpose I/O (GPIO)
The following are the descriptions of how each supported feature is used for the Intel® ICH7R
on the board.
3.2.2.1.1
SATA Controller
The Intel® ICH7R contains four SATA ports. The data transfer rates are up to 150Mbyte/s per
port.
3.2.2.2
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt
Controller)
The Intel® ICH7R provides the functionality of two-cascaded 82C59 with 15 interrupts handling.
It supports a processor system bus interrupt.
3.2.2.2.1
Advanced Programmable Interrupt Controller (APIC)
Interrupt generation and notification to the processor is done by the APICs in the Intel® ICH7R
using messages on the front side bus.
3.2.2.2.2
Universal Serial Bus (USB) Controller
The Intel® ICH7R contains one EHCI USB 2.0 controller and four USB ports. The USB
controller moves data between main memory and up to four USB connectors. All ports function
identically and with the same bandwidth. The Intel® Entry Server Board SE7230CA1-E
implements four ports on the board.
Two external USB ports are provided on the back of the server board. The Universal Serial Bus
Specification, Revision 1.1, defines the external connectors.
The third/fourth USB port is optional and can be accessed by cabling from an internal 9-pin
connector located on the server board to an external USB port located either in front of or the
rear of a given chassis.
3.2.2.2.3
Enhanced Power Management
One of the embedded functions of the Intel® ICH7R is a power management controller. This is
used to implement ACPI-compliant power management features. The server board supports
sleep states S0, S1, S4, and S5.
Revision 1.0
13
Functional Architecture
3.3
Intel® Entry Server Board SE7230CA1-E TPS
Memory Sub-System
The server board supports up to four DIMM sockets for a maximum memory capacity of 8 GB.
The DIMM organization is x72, which includes eight ECC check bits. The memory interface runs
at 533/667MTs. The memory controller supports the following:
ƒ
ƒ
ƒ
ƒ
Memory scrubbing
Single-bit error correction
Multiple-bit error detection
Intel® x4 Single Device Data Correction support with x4 DIMMs
Memory can be implemented with either single-sided (one row) or double-sided (two row)
DIMMs
3.3.1
Memory Configuration
The memory interface between the MCH and the DIMMs is a 64-bit (non-ECC) or 72-bit (ECC)
wide interface.
There are two banks of DIMMs, labeled Bank 1 and Bank 2. Bank 1 contains DIMM socket
locations DIMM_1A and DIMM_2A. Bank 2 contains DIMM socket locations DIMM_1B and
DIMM_2B. The sockets associated with each bank or channel are located next to each other
and the DIMM socket identifiers are marked on the server board silkscreen, near the DIMM
socket. Bank 1 is associated with Memory Channel A while Bank 2 is associated with Memory
Channel B. When only two DIMM modules are being used, the population order must be
DIMM_1A, DIMM_1B to ensure dual channel operating mode.
In order to operate in dual channel dynamic paging mode, the following conditions must be met:
ƒ
ƒ
Two identical DIMMs are installed, one each in DIMM_1A and DIMM_1B
Four identical DIMMs are installed (one in each socket location)
Note: Installing only three DIMMs is not supported. Do not use DIMMs that are not matched
(same type and speed). Use of identical memory parts is always the preferred method.
DIMM and memory configurations must adhere to the following:
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
14
DDR2 533/667, un-buffered, DDR2 DIMM modules
DIMM organization: x72 ECC or x 64 Non-ECC
Pin count: 240
DIMM capacity: 256 MB, 512 MB, 1 GB and 2 GB DIMMs
Serial PD: JEDEC Rev 2.0
Voltage options: 1.8 V
Interface: SSTL2
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Table 6. Memory Bank Labels and DIMM Population Order
Location
J2D1
DIMM Label
(DIMM_1A)
A
Channel
1
Population Order
J1D3
(DIMM_2A)
A
3
J1D2
(DIMM_1B)
B
2
J1D1
(DIMM_2B)
B
4
Figure 3. Memory Bank Label Definition
Revision 1.0
15
Functional Architecture
Intel® Entry Server Board SE7230CA1-E TPS
Table 7. Characteristics of Dual/Single Channel Configuration with or without Dynamic Mode
Throughput Level
Highest
Lowest
3.3.2
Configuration
Dual channel with dynamic paging mode
Characteristics
All DIMMs matched
Dual channel without dynamic paging mode
DIMMs matched from Channel A to Channel B
DIMMs not matched within channels
Single channel with dynamic paging mode
Single DIMM or DIMMs matched with a
channel
Single channel without dynamic paging
mode
DIMMs not matched
Memory DIMM Support
The board supports un-buffered (not registered) DDR2 533/667 ECC or Non-ECC DIMMs
operating at 533/667MT/s. Only DIMMs tested and qualified by Intel or a designated memory
test vendor are supported on this board. A list of qualified DIMMs is available at
http://support.intel.com/support/motherboards/server/.
Note all DIMMs are supported by design, but only fully qualified DIMMs will be supported on the
board.
The minimum supported DIMM size is 256 MB. Therefore, the minimum main memory
configuration is 1 x 256 MB or 256 MB. The largest size DIMM supported is 2 GB and as such,
the maximum main memory configuration is 8 GB implemented by 4 x 2-GB DIMMs.
ƒ
ƒ
ƒ
ƒ
ƒ
3.4
3.4.1
Only un-buffered DDR2 533/667 compliant, ECC x8 and non-ECC x8 or x16 memory
DIMMs are supported.
ECC single-bit errors (SBE) will be corrected; multiple-bit error (MBE) will only be
detected.
Intel® Entry Server Board SE7230CA1-E supports Intel® x4 Single Device Data
Correction with x4 DIMMs.
The maximum memory capacity is 8 GB via four 2 GB DIMM modules.
The minimum memory capacity is 256 MB via a single 256 MB DIMM module.
I/O Sub-System
PCI Subsystem
The primary I/O buses for the Intel® Entry Server Board SE7230CA1-E are two independent
PCI bus segments providing PCI, PCI Express*. The PCI buses comply with the PCI Local Bus
Specification, Rev 2.3.
PCI Segments A and B are directed through the Intel® ICH7R. The following table lists the
characteristics of the two PCI bus segments.
16
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Table 8. PCI Bus Segment Characteristics
PCI Bus
Segment
A
B
Voltage
3.3V
3.3V
3.4.1.1
Width
32 bits
1 lane
Speed
Type
PCI I/O Card Slots
33MHz
PCI 32
NIC 1
1.5GHz
x1 PCI
Express*
NIC 2
P32-A: 32-bit, 33-MHz PCI Subsystem
The Intel® ICH7R provides a Legacy 32-bit PCI subsystem and acts as the central resource on
this PCI interface. P32-A supports the following embedded devices and connectors:
ƒ
One Intel® 82541PI Network Controller
All 32-bit/33-MHz PCI I/O for the board is directed through the Intel® ICH7R. The 32-bit/33-MHz
PCI segment created by the Intel® ICH7R is known as PCI Segment A. Segment A supports the
following embedded device:
ƒ
One 10/100/1000-T Network Interface Controller: Intel® 82541PI Gigabit Ethernet
Controller.
3.4.1.1.1
Device IDs (IDSEL)
Each device under the PCI hub bridge has its IDSEL signal connected to one bit of AD (31:16),
which acts as a chip select on the PCI bus segment in configuration cycles. This determines a
unique PCI device ID value for use in configuration cycles. The following table shows the bit to
which each IDSEL signal is attached for Segment A devices and the corresponding device
description.
Table 9. Segment A Configuration IDs
IDSEL Value
21
3.4.1.1.2
Device
Intel® 82541PI LAN (NIC2)
Segment A Arbitration
PCI Segment A supports two PCI devices: the Intel® ICH7R and one PCI bus masters (NIC). All
PCI masters must arbitrate for PCI access, using resources supplied by the Intel® ICH7R. The
host bridge PCI interface (ICH7R) arbitration lines REQx* and GNTx* are a special case in that
they are internal to the host bridge. The following table defines the arbitration connections.
Table 10. Segment A Arbitration Connections
Server Board Signals
PCI REQ_N5/GNT_N5
Revision 1.0
Device
Intel® 82541PI LAN (NIC2)
17
Functional Architecture
3.4.1.2
Intel® Entry Server Board SE7230CA1-E TPS
PCI Interface for ATI Video subsystem
The graphics subsystem is connected to the Intel® ICH7R via a 32/33MHz PCI bus.
3.4.2
Interrupt Routing
The board interrupt architecture accommodates both PC-compatible PIC mode and APIC mode
interrupts through use of the integrated I/O APICs in the ICH7R.
3.4.2.1
Legacy Interrupt Routing
For PC-compatible mode, the ICH7R provides two 82C59-compatible interrupt controllers. The
two controllers are cascaded with interrupt levels 8-15 entering on level 2 of the primary
interrupt controller (standard PC configuration). A single interrupt signal is presented to the
processors, to which only one processor will respond for servicing. The Intel® ICH7R contains
configuration registers that define which interrupt source logically maps to I/O APIC INTx pins.
The ICH7R handles both PCI and IRQ interrupts. The Intel® ICH7R translates these to the
APIC bus. The numbers in the following table indicate the Intel® ICH7R PCI interrupt input pin
to which the associated device interrupt (INTA, INTB, INTC, INTD, INTE, INTF, INTG, INTH for
PCI bus and PXIRQ0, PXIRQ1, PXIRQ2, PXIRQ3 for PCI-X bus) is connected. The Intel®
ICH7R I/O APIC exists on the I/O APIC bus with the processors.
Table 11. PCI Interrupt Routing/Sharing
Intel® 82541PI
Interrupt
INT A
PIRQB
ATIES 1000
PIRQC
3.4.2.2
INT B
INT C
INT D
APIC Interrupt Routing
For APIC mode, the server board interrupt architecture incorporates three Intel® I/O APIC
devices to manage and broadcast interrupts to local APICs in each processor. The Intel® I/O
APICs monitor each interrupt on each PCI device; including PCI slots in addition to the ISA
compatibility interrupts IRQ (0-15).
When an interrupt occurs, a message corresponding to the interrupt is sent across a three-wire
serial interface to the local APICs. The APIC bus minimizes interrupt latency time for
compatibility interrupt sources. The I/O APICs can also supply greater than 16 interrupt levels to
the processor(s). This APIC bus consists of an APIC clock and two bidirectional data lines.
3.4.2.3
Legacy Interrupt Sources
The following table recommends the logical interrupt mapping of interrupt sources on the board.
The actual interrupt map is defined using configuration registers in the ICH7R.
18
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Table 12. Interrupt Definitions
ISA Interrupt
INTR
Processor interrupt.
Description
NMI
NMI to processor.
IRQ0
System timer
IRQ1
Keyboard interrupt.
IRQ2
Slave PIC
IRQ3
Serial port 1 interrupt from Super I/O* device, user-configurable.
IRQ4
Serial port 1 interrupt from Super I/O* device, user-configurable.
IRQ5
IRQ6
Floppy disk.
IRQ7
Generic
IRQ8_L
Active low RTC interrupt.
IRQ9
SCI*
IRQ10
Generic
IRQ11
Generic
IRQ12
Mouse interrupt.
IRQ13
Floaty processor.
IRQ14
Compatibility IDE interrupt from primary channel IDE devices 0 and 1.
IRQ15
Secondary IDE Cable
SMI*
System Management Interrupt. General purpose indicator sourced by the Intel® ICH7R to
the processors.
3.4.2.4
Serialized IRQ Support
The Intel® Entry Server Board SE7230CA1-E supports a serialized interrupt delivery
mechanism. Serialized Interrupt Requests (SERIRQ) consists of a start frame, a minimum of 17
IRQ / data channels, and a stop frame. Any slave device in the quiet mode may initiate the start
frame. While in the continuous mode, the start frame is initiated by the host controller.
3.5
PCI Error Handling
The PCI bus defines two error pins, PERR# and SERR#, for reporting PCI parity errors and
system errors, respectively. In the case of PERR#, the PCI bus master has the option to retry
the offending transaction, or to report it using SERR#. All other PCI-related errors are reported
by SERR#. SERR# is routed to NMI if enabled by BIOS.
Revision 1.0
19
Functional Architecture
Intel® Entry Server Board SE7230CA1-E TPS
ICH7R IOAPIC 0
DMI INTERFACE
IRQ0
IRQ1
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
IRQ8
IRQ9
IRQ10
IRQ11
IRQ12
IRQ13
IRQ14
IRQ15
IRQ16
IRQ17
IRQ18
IRQ19
IRQ20
IRQ21
IRQ22
IRQ23
ICH7R
ICH7R
8259PIC
INTR
MCH
CPU
Figure 4. Interrupt Routing Diagram
20
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Super I/O
Timer
Keyboard
Cascade
Serial Port2/ISA
ISA
Floppy/ISA
ISA
SCI/ISA
ISA
ISA
SERIRQ
ICH7R Interrupt
Routing
PCI Interface
RTC
SERIRQ
Serialized IRQ Interface
Serial Port1/ISA
Mouse/ISA
Coprocessor Error
P IDE/ISA
Not Used
N/A
PIRQA#
Intel® 82541PI
PIRQB#
ATI ES1000
PIRQC#
N/A
PIRQD#
N/A
PIRQE#
N/A
PIRQF#
N/A
PIRQG#
N/A
PIRQH#
Figure 5. Intel® ICH7R Interrupt Routing Diagram
Revision 1.0
21
Functional Architecture
3.5.1
Intel® Entry Server Board SE7230CA1-E TPS
Video Support
The Intel® Entry Server Board SE7230CA1-E includes an integrated stand-alone ATI* ES1000
graphics engine that supports standard SVGA drivers with analog display capabilities. The
graphics subsystem has 16 MB of dedicated memory to support the onboard video controller.
The server board provides a standard 15-pin VGA connector at the rear of the system.
3.5.1.1
Video Modes
Table 13. Video Modes
2D Mode
Refresh Rate (Hz)
2D Video Mode Support
16 bpp
24 bpp
Supported
Supported
32 bpp
Supported
640x480
60, 72, 75, 90, 100
8 bpp
Supported
800x600
60, 70, 75, 90, 100
Supported
Supported
Supported
Supported
1024x768
60, 72, 75, 90, 100
Supported
Supported
Supported
Supported
1280x1024
43, 60
Supported
Supported
Supported
Supported
1280x1024
70, 72
Supported
Supported
Supported
1600x1200
60, 66
Supported
Supported
Supported
Supported
1600x1200
76, 85
Supported
Supported
Supported
3D Mode
Refresh Rate (Hz)
640x480
60,72,75,90,100
8 bpp
Supported
800x600
60,70,75,90,100
Supported
–
3D Video Mode Support with Z Buffer Enabled
16 bpp
24 bpp
32 bpp
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
1024x768
60,72,75,90,100
Supported
Supported
1280x1024
43,60,70,72
Supported
Supported
1600x1200
60,66,76,85
Supported
3D Mode
Refresh Rate (Hz)
–
–
–
–
–
–
3D Video Mode Support with Z Buffer Disabled
16 bpp
24 bpp
32 bpp
Supported
Supported
Supported
640x480
60,72,75,90,100
8 bpp
Supported
800x600
60,70,75,90,100
Supported
Supported
Supported
Supported
1024x768
60,72,75,90,100
Supported
Supported
Supported
Supported
1280x1024
43,60,70,72
Supported
Supported
Supported
1600x1200
60,66,76,85
Supported
Supported
3.5.2
Network Interface Controller (NIC)
–
–
–
The Intel® Entry Server Board SE7230CA1-E supports two 10/100/1000 Base-T network
interfaces.
ƒ
ƒ
22
NIC1 is an Intel® 82573E Gigabit Ethernet Controller resourced with a x1 PCI Express*
interface from the Intel® ICH7R (PCI Segment B).
NIC2 is an Intel® 82541PI Gigabit Ethernet Controller resourced with a 32bit/33MHz PCI
Segment from the Intel® ICH7R (PCI Segment A).
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Functional Architecture
Both the Intel® 82573E and Intel® 82541PI Gigabit Ethernet Controllers are single, compact
components with an integrated gigabit Ethernet Media Access Control (MAC) and physical layer
(PHY) function. The Intel® 82573E and Intel® 82541PI Gigabit Ethernet Controller allow for a
gigabit Ethernet implementation in a very small area that is footprint compatible with current
generation 10/100 Mbps Fast Ethernet designs. The Intel® 82541PI Gigabit Ethernet Controller
and Intel® 82573E integrate fourth and fifth generation (respectively) gigabit MAC design with
fully integrated physical layer circuitry to provide a standard IEEE 802.3 Ethernet interface for
1000BASE-T, 100BASE-TX, and 10BASE-T applications (802.3, 802.3u, and 802.3ab). The
controller is capable of transmitting and receiving data at rates of 1000 Mbps, 100 Mbps, or
10 Mbps. In addition to managing MAC and PHY layer functions, the controller provides a 32-bit
wide direct Peripheral Component Interconnect (PCI) 2.3 compliant interface capable of
operating at 33 or 66 MHz.
3.5.2.1
NIC Connector and Status LEDs
The NICs drive two LEDs located on each network interface connector.
Table 14. Intel® 82573E (NIC 1 and NIC 2)
LED
Left
Right
3.5.3
Color
Off
LED State
Condition
LAN link is not established.
Green
On
LAN link is established.
Blinking
LAN activity is occurring.
N/A
Off
10 Mbit/sec data rate is selected.
Green
On
100 Mbit/sec data rate is selected.
Yellow
On
1000 Mbit/sec data rate is selected.
Super I/O Chip
The SMsC* LP47M182NR SIO devices contain all of the necessary circuitry to control the
serial/parallel ports, floppy disk, PS/2-compatible keyboard, mouse and hardware monitor
controller. The server board implements the following features:
ƒ
ƒ
ƒ
ƒ
ƒ
GPIOs
Two serial port
Local hardware monitoring
Wake up control
System health support
3.5.3.1
Serial Ports
The board provides a serial port implemented as an external 9-pin serial port; an internal 9-pin
serial port is also provided. The following sections provide details on the use of the serial port.
Revision 1.0
23
Functional Architecture
3.5.3.1.1
Intel® Entry Server Board SE7230CA1-E TPS
Serial Port A
Serial A is a standard DB9 interface located at the rear I/O panel of the server board, above the
video connector. Serial A is designated by a Serial_A on the silkscreen. The reference
designator is J3A1.
Serial B is a 9-pin header interface located near the DIMMs. Serial B is designated by a
Serial_B on the silkscreen. The reference designator is J1C2.
Table 15. Serial A Header Pin-out
Pin
Signal Name
1
DCD
2
RX
3
TX
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Serial Port A Header Pin-out
Table 16. Serial B Header Pin-out
Pin
3.5.3.2
Signal Name
1
DCD
2
DSR
3
RX
4
RTS
5
TX
6
CTS
7
DTR
8
RI
9
GND
Serial Port B Header Pin-out
Keyboard and Mouse Support
USB ports can be used to support keyboard and mouse.
3.5.3.3
Wake-up Control
The Super I/O contains functionality that allows various events to control the power-on and
power-off the system.
3.5.4
BIOS Flash
The board incorporates an 8-MB firmware Hub flash memory component. This flash device is
connected through the LPC bus from the ICH7R controller.
24
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
3.5.5
The I
ƒ
ƒ
ƒ
Functional Architecture
System Health Support
2
3.6
C interface to the Heceta* sensors (fan monitor and control [FMC]) support:
One PWM-based fan control
Software or local temperature feedback control
Chassis intrusion detection
Replacing the Back-Up Battery
The lithium battery on the server board powers the RTC for up to ten years in the absence of
power. When the battery starts to weaken, it loses voltage, and the server settings stored in
CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer
service representative or dealer for a list of approved devices.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent
type recommended by the equipment manufacturer. Discard used batteries according to
manufacturer’s instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af
samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som
rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
Revision 1.0
25
System BIOS
Intel® Entry Server Board SE7230CA1-E TPS
4.
System BIOS
4.1
BIOS Setup Utility
The BIOS Setup Utility is provided to perform system configuration changes and to display
current settings and environment information.
The BIOS Setup Utility stores configuration settings in system non-volatile storage. Changes
affected by BIOS Setup will not take effect until the system is rebooted. The BIOS Setup Utility
can be accessed when prompted during POST by using the F2 key.
4.1.1
Localization
The BIOS Setup program and help messages currently support up to six languages. However,
depending upon space requirements, the following applies with regard to language support.
ƒ
ƒ
4.1.2
Flex BIOS handles languages based upon OEM requirements. This is a stretch goal.
The default language is US English. This is the only language that is guaranteed to be
properly translated and functional.
Configuration Reset
There are different mechanisms for resetting the system configuration to default values. When a
reset system configuration request is detected, the BIOS will load the default system
configuration values during the next POST.
A reset system configuration request can be generated by moving the Clear CMOS jumper.
4.1.3
Keyboard Commands
The bottom right portion of the Setup screen provides a list of commands that are used to
navigate through the Setup utility. These commands are displayed at all times.
Each Setup menu page contains a number of features. Except those used for informative
purposes, each feature is associated with a value field. This field contains user-selectable
parameters. Depending on the security option chosen and in effect by the password, a menu
feature’s value may or may not be changeable. If a value is non-changeable, the feature’s value
field is inaccessible. It displays as “grayed out.”
The Keyboard Command Bar supports the following keys.
Table 17. BIOS Setup Keyboard Command Bar Options
Key
Enter
26
Option
Execute Command
Description
The Enter key is used to activate sub-menus when the selected feature is a sub-menu,
or to display a pick list if a selected option has a value field, or to select a sub-field for
multi-valued features like time and date. If a pick list is displayed, the Enter key will
undo the pick list, and allow another selection in the parent menu.
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Option
System BIOS
Key
ESC
Exit
Description
The ESC key provides a mechanism for backing out of any field. This key will undo the
pressing of the Enter key. When the ESC key is pressed while editing any field or
selecting features of a menu, the parent menu is re-entered.
When the ESC key is pressed, any sub-menu, the parent menu is re-entered. When the
ESC key is pressed, any major menu, the exit confirmation window is displayed and the
user is asked whether changes can be discarded. If No is selected and the Enter key is
pressed, or if the ESC key is pressed, the user is returned to where they were before
ESC was pressed without affecting any existing any settings. If Yes is selected and the
Enter key is pressed, setup is exited and the BIOS continues with POST.
↑
Select Item
The up arrow is used to select the previous value in a pick list, or the previous options
in a menu item's option list. The selected item must then be activated by pressing the
Enter key.
↓
Select Item
The down arrow is used to select the next value in a menu item’s option list, or a value
field’s pick list. The selected item must then be activated by pressing the Enter key.
↔
Select Menu
The left and right arrow keys are used to move between the major menu pages. The
keys have no affect if a sub-menu or pick list is displayed.
Tab
Select Field
The Tab key is used to move between fields. For example, Tab can be used to move
from hours to minutes in the time item in the main menu.
-
Change Value
The minus key on the keypad is used to change the value of the current item to the
previous value. This key scrolls through the values in the associated pick list without
displaying the full list.
+
Change Value
The plus key on the keypad is used to change the value of the current menu item to the
next value. This key scrolls through the values in the associated pick list without
displaying the full list. On 106-key Japanese keyboards, the plus key has a different
scan code than the plus key on the other keyboard, but will have the same effect.
F9
Setup Defaults
Pressing F9 causes the following to appear:
Load Setup Defaults?
[OK] [Cancel]
If OK is selected and the Enter key is pressed, all setup fields are set to their default
values. If Cancel is selected and the Enter key is pressed, or if the ESC key is pressed,
the user is returned to where they were before F9 was pressed without affecting any
existing field values.
F10
Save Changes and
Exit
Pressing F10 causes the following message to appear:
Save configuration changes and exit setup?
[OK] [Cancel]
If OK is selected and the Enter key is pressed, all changes are saved and setup is
exited. If Cancel is selected and the Enter key is pressed, or the ESC key is pressed,
the user is returned to where they were before F10 was pressed without affecting any
existing values.
4.1.4
Entering BIOS Setup
The BIOS Setup Utility can be accessed by pressing the [F2] hotkey during POST.
Revision 1.0
27
System BIOS
Intel® Entry Server Board SE7230CA1-E TPS
4.1.4.1
Main Menu
The first screen displayed when entering the BIOS Setup Utility is the Main Menu selection.
This screen displays the major menu selections available. The following tables describe the
available options on the top-level and lower-level menus. Default values are in bold text.
Table 18. BIOS Setup, Main Menu Options
Feature
BIOS Version
N/A
Options
N/A
Help Text
Description
BIOS ID string (excluding the build
time and date)
Processor Type
N/A
N/A
Hyper Threading
Technology
Enable
Disable
N/A
Select disable if your operating
system does not support Hyper
Threading
Processor speed
N/A
N/A
Calculates processor speed
System Bus speed
N/A
N/A
Displays the system bus speed
System Memory
speed
N/A
N/A
Displays the system memory speed
L2 Cache RAM
N/A
N/A
Total Memory
N/A
N/A
Detects amount of physical
memory
Memory Mode
N/A
N/A
Displays the memory mode
Memory Channel
1A
N/A
N/A
Displays the memory detected
Memory Channel
2A
N/A
N/A
Memory Channel
1B
N/A
N/A
Memory Channel
2B
N/A
N/A
Additional System
Information
N/A
N/A
Selects submenu with additional
system information details
System Date
DAY MM/DD/YYYY
Use [TAB] or [SHIFT-TAB] to
select a field.
Use [+] or [-] to configure system
date.
Configures the system date.
Default is [Tue 01/01/2002]. Day of
the week is automatically calculated
System Time
HH:MM:SS
Use [TAB] or [SHIFT-TAB] to
select a field.
Use [+] or [-] to configure system
time.
Configures the system time on a
24-hour clock. Default is 00:00:00
4.1.4.1.1
Additional System Information Sub-menu
Table 19. BIOS Setup, Additional System Information Sub-menu Selections
Feature
System
Information
Manufacturer
28
Options
Help Text
Description
Informational display.
N/A
N/A
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Feature
Product Name
N/A
Options
N/A
Version
N/A
N/A
Serial Number
N/A
N/A
Manufacturer
N/A
N/A
Product Name
N/A
N/A
Version
N/A
N/A
Serial Number
N/A
N/A
System BIOS
Help Text
Description
Server Board
Information
Chassis
Information
Manufacturer
N/A
N/A
Version
N/A
N/A
Serial Number
N/A
N/A
Asset Tag
N/A
N/A
4.1.4.2
Advanced Menu
Table 20. BIOS Setup, Advanced Menu Options
Feature
Boot configuration
Options
N/A
Help Text
Configure boot devices
Description
Selects submenu
Peripheral configuration
N/A
Configure peripheral devices
Selects submenu
Drive configuration
N/A
Configure primary master slave and secondary
master and slave
Selects submenu
Event log configuration
N/A
View the events in the event log or clear current
events
Selects submenu
Video configuration
N/A
Configure video
Selects submenu
Hardware monitoring
N/A
Configure hardware monitoring
Selects submenu
Chipset configuration
N/A
Configure chipset
Selects submenu
Management
configuration
N/A
Configure management
Selects submenu
USB configuration
N/A
Configure USB support.
Selects submenu
4.1.4.2.1
Boot Configuration Sub-menu
Table 21. BIOS Setup, Advanced Menu, Boot Configuration Sub-menu Selections
Feature
CPU Fan Control
Options
Disable
Enable
Help Text
Enable or Disable CPU fan control
System Fan Control
Disable
Enable
N/A
Revision 1.0
Description
29
System BIOS
Intel® Entry Server Board SE7230CA1-E TPS
Feature
Lowest Fan speed
Options
Slow
Off
Help Text
These options define the lower limit of chassis fan
speed operation.
Slow: At low system temperatures, the fans will
continue to run at a slow speed.
Off: At low system temperatures, the fans will turn
off.
Max CPUID Value Limit
Disable
Enable
This should be enabled in order to boot legacy
operating systems that cannot support CPUs with
extended CPUID functions
Display Setup Prompt
Off
On
Displays “Press F2 to Enter Setup” message during
POST
4.1.4.2.2
Description
Peripheral Configuration Sub-menu
Table 22. BIOS Setup, Advanced Menu, Peripheral Configuration Sub-menu
Feature
Serial Port A
Options
Disable
Enable
Help Text
Enable or Disable the On board
Serial port
Serial Port B
Disable
Enable
Enable or Disable the On board
Serial port
PCI Express* Onboard LAN
Disable
Enable
Enable or Disable the PCI Express*
On-board LAN Device (NIC1 Intel
82573E)
PCI On-board LAN
Disable
Enable
Enable or Disable the PCI On-board
LAN Device (NIC2 Intel 82541PI)
4.1.4.2.3
Description
Drive Configuration Sub-menu
Table 23. BIOS Setup, Advanced Menu, Drive Configuration Menu Options
Feature
Use Automatic Mode
Options
Disable
Enable
Use Serial ATA as
Enable
Disable
Enable or Disable the onboard Serial ATA ports
ATA/IDE Mode
Legacy
Configure SATA for either
Enhanced (native) or Legacy
mode
Controls state of integrated S-ATA
and P-ATA controller.
Enhanced
Help Text
Description
Configure SATA as
IDE
RAID
AHCI
Configure SATA into the
appropriate type
In Enhance mode this item will
display.
S.M.A.R.T.
Enable
Disable
S.M.A.R.T. stands for SelfMonitoring, Analysis, and
Reporting Technology
The Auto setting should work in
most cases.
SATA Port 0
N/A
N/A
Displays the SATA HDD detected
30
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Feature
SATA Port 1
Options
Hard Disk Pre-Delay
(Sec)
4.1.4.2.4
System BIOS
Help Text
N/A
N/A
0
5
10
15
20
25
30
35
Indicates the amount of time
in seconds that the firmware
will wait to detect hard disk
drives
Description
Displays the SATA HDD detected
Event Log Configuration Sub-menu
Table 24. BIOS Setup, Advanced Menu, Event Log Configuration Sub-menu Selections
Feature
View Event Log
Options
Help Text
Views the events
Description
Clears the events
When Disable is selected, the
event log will be cleared during the
next system reset
Clear Event Log
Disable
Enable
Event Logging
Disable
Enable
Enables/Disables the event log
ECC Event Logging
Disable
Enable
Enables/Disables ECC Events
recorded in the event log
4.1.4.2.5
Video Configuration Sub-menu
Table 25. BIOS Setup, Advanced Menu, Video Configuration Sub-menu Selections
Feature
Console Redirection Serial
Port
Revision 1.0
Options
Disable
Enable
Help Text
Enable/Disable Console
Redirection via Serial Port
(COM1). Video resolution set
to 640x480. Serial Port baud
rate set to 57600
Description
31
System BIOS
4.1.4.2.6
Intel® Entry Server Board SE7230CA1-E TPS
Hardware Monitoring
Table 26. BIOS Setup, Advanced Menu, Hardware Monitoring Sub-menu Selections
Feature
Hardware
Monitoring
Options
Help Text
N/A
N/A
Display H/W
Settings
N/A
N/A
Processor Fan
Speed
2280
System Fan1
Speed
0000
System Fan2
Speed
0000
Processor Temp
64 C
Internal Temp
34 C
V12.0
12.000 V
V5.0
5.084 V
V3.3
3.250 V
V1.5
1.516 V
Vccp
1.324 V
4.1.4.2.7
Description
Selects submenu, determined by
the real system.
Chipset Configuration Sub-menu Selections
Table 27. BIOS Setup, Advanced Menu, Chipset Configuration Sub-menu Selections
Feature
Memory
Configuration
Options
Help Text
N/A
N/A
PCI Express*
Configuration
N/A
N/A
PCI Latency timer
32
64
96
128
160
192
224
248
Description
Selects submenu with memory
configuration details
Selects submenu with PCI
Express* configuration details
4.1.4.2.7.1
Memory Configuration Sub-menu
This sub-menu provides information about the DIMMs detected by the BIOS. The DIMM number
is printed on the server board next to each device.
32
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
System BIOS
Table 28. BIOS Setup, Advanced Menu, Chipset Configuration, Memory Configuration Sub-menu
Selections
Feature
Memory correction
Options
Non-ECC
ECC
Help Text
Allow the user to turn error reporting on or off if the
system and all the memory installed supports ECC (Error
Correction Code)
Memory frequency
N/A
N/A
SDRAM tCL
N/A
N/A
SDRAM tRCD
N/A
N/A
SDRAM tRP
N/A
N/A
SDRAM tRASmin
N/A
N/A
DDR2 voltage
N/A
N/A
Total memory
N/A
N/A
Memory mode
N/A
N/A
DIMM 1A
N/A
N/A
DIMM 2A
N/A
N/A
DIMM 1B
N/A
N/A
DIMM 2B
N/A
N/A
Description
Informational
display
4.1.4.2.7.2
PCI Configuration Sub-menu
This sub-menu provides control over PCI devices and their option ROMs. If the BIOS is
reporting POST error 146, use this menu to disable option ROMs that are not required to boot
the system.
Table 29. BIOS Setup, Advanced Menu, Chipset Configuration, PCI Express* Configuration Submenu Selections
Feature
PEG Negotiated Width
Options
N/A
Compliance Test
Pattern
Disable
Enable
4.1.4.2.8
Help Text
Description
N/A
N/A
Management Configuration Sub-menu
Table 30. BIOS Setup, Advanced Menu, Management Configuration Sub-menu Selections
Feature
Enter Intel@ AMT BX
Setup
Revision 1.0
Options
Disable
Enable
Help Text
Allows Intel® AMT to be force enabled or
disabled. Also controls ability to
individually set AMTBX, SOL, IDER
capabilities.
Description
33
System BIOS
Intel® Entry Server Board SE7230CA1-E TPS
4.1.4.2.9
USB Mass Storage Device Configuration Sub-menu
Table 31. BIOS Setup, Advanced Menu, USB Mass Storage Device Configuration Sub-menu
Selections
Feature
USB 2.0
4.1.4.3
Options
Help Text
N/A
Enable
Disable
Description
Enable/Disable all USB ports
Security Menu
Table 32. BIOS Setup, Security Menu Options
Feature
Supervisor
password
N/A
Options
Help Text
Install / Not install
Description
Informational display
User password
N/A
Install / Not install
Informational display
Set supervisor
password
N/A
Set supervisor password
Set password to null to clear
Set user password
N/A
Set user password
This node is grayed out until
Admin password is installed.
Set password to null to clear.
Chassis intrusion
Disable
Enable
N/A
Chassis intrusion enable will log
chassis intrusion to the event log
Disable
N/A
Enables/Disables the CPU execute
disable bit.
XD technology
Enable
4.1.4.4
Power Menu
Table 33. BIOS Setup, Power Menu Selections
Feature
After Power Failure
Options
Stay off
Last State
Power On
Help Text
Determines the mode of operation if a power
loss occurs. Stays Off: System will remain off
once power is restored. Last State: Restores
system to the same state it was before power
failed. Power On: System will power on once
power is restored.
Wake on LAN from S5
Stay Off
Power On
Determines the action taken when the system
power is off and a PCI Power management
wake-up event occurs.
34
Description
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
4.1.4.5
System BIOS
Boot Menu
Table 34. BIOS Setup, Boot Menu Selections
Feature
Boot menu type
Boot device priority
Options
Normal
Advance
Varies
Hard drive order
Help Text
Description
N/A
N/A
Select the boot drive
order
Varies
N/A
Select the boot
order of available
hard drive devices
CD/DVD-ROM drive order
Varies
N/A
Select the boot
order of available
CD/DVD devices
Removable drive order
Varies
N/A
Select the boot
order of removable
devices
Boot to optical devices
Disable
Enables or disables boot to optical devices
Boot to network
Enable
Disable
Enable
Disable
USB boot
Enable
Disable
Boot to removable devices
Enables or disables boot to removable devices
Enables or disables boot to network
Enables or disables USB boot
Enable
Zip emulation type
4.1.4.6
Sets the emulation type for zip drives
Floppy
Hard Disk
Exit menu
Table 35. BIOS Setup, Exit Menu Selections
Feature
Exit saving
changes
Options
N/A
Help Text
Exit system setup after saving the changes.
F10 key can be used for this operation.
Exit discarding
changes
N/A
Exit system setup without saving any changes.
ESC key can be used for this operation.
Load optimal
defaults
N/A
Load Setup default values for all the setup questions.
F9 key can be used for this operation.
Load custom
defaults
N/A
Load custom defaults.
Save custom
defaults
N/A
Save custom defaults.
Discard
changes
N/A
Discard changes done so far to any of the setup questions.
Revision 1.0
35
System BIOS
Intel® Entry Server Board SE7230CA1-E TPS
The BIOS Setup Utility is a text-based utility that allows the user to configure the system and
view current settings and environment information for the platform devices. The Setup Utility
controls the platform's built-in devices.
The BIOS Setup interface consists of a number of pages or screens. Each page contains
information or links to other pages. The first page in Setup displays a list of general categories
as links. These links lead to pages containing a specific category’s configuration.
The following sections describe the look and behavior for platform Setup.
4.1.5
Operation
BIOS Setup has the following features:
ƒ
ƒ
Localization: BIOS Setup uses the Unicode standard and is capable of displaying Setup
forms in all languages currently included in the Unicode standard. The Intel® Server
Board BIOS will only be available in English.
BIOS Setup is functional via console redirection over various terminal emulation
standards. This may limit some functionality for compatibility, e.g., usage of colors or
some keys or key sequences or support of pointing devices.
4.1.5.1
Setup Page Layout
The setup page layout is sectioned into functional areas. Each occupies a specific area of the
screen and has dedicated functionality. The following table lists and describes each functional
area.
Table 36. BIOS Setup Page Layout
Functional Area
Title Bar
Description
The title bar is located at the top of the screen and displays the title of the form
(page) the user is currently viewing. It may also display navigational information.
Setup Item List
The Setup Item List is a set of controllable and informational items. Each item in the
list occupies the left and center columns in the middle of the screen. The left
column, the "Setup Item", is the subject of the item. The middle column, the
"Option", contains an informational value or choices of the subject.
A Setup Item may also be a hyperlink that is used to navigate formsets (pages).
When it is a hyperlink, a Setup Item only occupies the “Setup Item” column.
Item Specific Help Area
The Item Specific Help area is located on the right side of the screen and contains
help text for the highlighted Setup Item. Help information includes the meaning and
usage of the item, allowable values, effects of the options, etc.
Keyboard Command Bar
The Keyboard Command Bar is located at the bottom right of the screen and
continuously displays help for keyboard special keys and navigation keys. The
keyboard command bar is context-sensitive—it displays keys relevant to current
page and mode.
Status Bar
The Status Bar occupies the bottom line of the screen. This line would display the
BIOS ID.
36
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
4.1.5.2
System BIOS
Entering BIOS Setup
BIOS Setup is started by pressing <F2> during boot time when the OEM or Intel logo is
displayed.
When Quiet Boot is disabled, there will be a message “press <F2> to enter setup” displayed on
the diagnostics screen.
4.1.5.3
Menu Selection Bar
The Menu Selection Bar is located at the top of the screen. It displays the major menu
selections available to the user.
4.2
Flash Memory Update Utility
4.2.1
BIOS Update
4.2.1.1
DOS Flash Utility
The BIOS can be upgraded from a HDD, diskette or CD-ROM using the Intel® iFlash Utility.
This utility supports the following functions:
• Updates the BIOS from a file or file set
• Verifies that the upgrade BIOS matches the target system to prevent accidentally installing
an incompatible BIOS
• RPM support (this includes VBIOS update, etc.). RPM support is a stretch goal.
4.2.1.2
iFlash Update Version Checking
When Flash BIOS Updates and Flash Language Updates are performed, a certain amount of
identification information will be checked before allowing the process to proceed. This checking
prevents a BIOS from being flashed into the wrong system, possibly causing boot failure. This
checking also prevents an incoherent language file from being flashed into a functional
machine.
4.2.1.3
Standard Flash BIOS Updates
Whenever a Flash BIOS Update is performed, the Board Identifier, the Board Revision and the
OEM Identifier must match.
4.2.1.4
Flash Language Updates
Whenever Flash Language Updates are performed, the Board Identifier, Board Revision, OEM
Identifier and Build Identifier must match.
4.2.1.5
RPM (Replaceable Program Modules) Updates
Whenever RPM operations are performed, the Board Identifier and Board Revision must match.
This currently only applies to video OPROM code.
ƒ
RPM support is a stretch goal.
Revision 1.0
37
System BIOS
4.2.2
Intel® Entry Server Board SE7230CA1-E TPS
O/S Present Flash Utility
The BIOS can be upgraded from a HDD, diskette or CD-ROM using the Intel® Express BIOS
Update utility. This utility supports the following functions:
ƒ Updates the BIOS from a file or file set
ƒ Verifies that the upgrade BIOS matches the target system to prevent accidentally
installing an incompatible BIOS
ƒ Works under Microsoft Windows 2000* and Microsoft Windows XP*
4.3 DMI/SMBIOS Support
4.3.1
DMI/SMBIOS Write Tool
A DMI/SMBIOS write utility allows OEMs to write their specific data into SMBIOS structures type
1 and 3 (chassis info – asset tag field only).
4.4
4.4.1
Operating System Boot, Sleep, and Wake
Boot Device Selection
The Boot Device Selection phase is responsible for controlling the boot of the system. The boot
option variables are set by an operating system during operating system installation or manually
added by the user through the Boot Maintenance Manager of Setup. The Boot Maintenance
Manager provides the capability to make permanent changes to the boot order. It is also
possible to change the first boot option for a single boot.
4.4.1.1
Server Management Boot Device Control
The IPMI 2.0 specification includes provisions for server management devices to set certain
boot parameters by setting boot flags. Among the boot flags (parameter #5 in the IPMI
specification) the BIOS will check data 1-3 for forced boot options.
The BIOS supports forced booting from the following:
ƒ
ƒ
ƒ
ƒ
ƒ
PXE
HDD (USB, SATA and PATA)
USB FDD
USB key
CD-ROM drive
On each boot, the BIOS invokes the Get System Boot Options command to determine what
changes to boot options have been set. The BIOS takes the appropriate action and clears these
settings.
4.4.2
Operating System Support
4.4.2.1
Microsoft Windows* Compatibility
Intel Corporation and Microsoft Corporation co-author design guides for system designers who
will use Intel® processors and Microsoft* operating systems. The Hardware Design Guide for
Microsoft Windows 2000 Server, Version 3.0 is intended for systems that are designed to work
38
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
System BIOS
with Windows Server* class operating systems. The specification further classifies the systems
and includes sets of requirements based on the intended usage for that system. For example, a
server system that is used in small home / office environments has different requirements than
one used for enterprise applications.
This product supports the Hardware Design Guide for Microsoft Windows 2000 Server, Version
3.0 enterprise requirements.
4.4.2.2
Advanced Configuration and Power Interface (ACPI)
The primary role of the ACPI BIOS is to supply the ACPI tables. POST creates the ACPI tables
and locates them in extended memory (above 1 MB). The location of these tables is conveyed
to the ACPI-aware operating system through a series of tables located throughout memory. The
format and location of these tables is documented in the publicly available ACPI specifications
(Advanced Configuration and Power Interface Specification, Revision 1.0b and Advanced
Configuration and Power Interface Specification, Revision 2.0).
The BIOS supports both ACPI 2.0 and 1.0b tables. To prevent conflicts with a non-ACPI-aware
operating system, the memory used for the ACPI tables is marked as “reserved” in INT 15h,
function E820h.
As described in the ACPI specifications, an ACPI-aware operating system generates an SMI to
request that the system be switched into ACPI mode. The BIOS responds by setting up all
system (chipset) specific configurations required to support ACPI, issues the appropriate
command to enable ACPI mode, and sets the SCI_EN bit as defined by the ACPI specification.
The system automatically returns to legacy mode on hard reset or power-on reset.
There are three runtime components to ACPI:
ƒ
ACPI Tables:
These tables describe the interfaces to the hardware. ACPI tables can make use of
ACPI Machine Language (AML), the interpretation of which is performed by the
operating system. The operating system contains and uses an AML interpreter that
executes procedures encoded in AML and is stored in the ACPI tables. AML is a
compact, tokenized, abstract machine language. The tables contain information about
power management capabilities of the system, APICs, and bus structure. The tables
also describe control methods that the operating system uses to change PCI interrupt
routing, control legacy devices in the Super I/O, find out the cause of a wake event, and
handle PCI hot plug, if applicable.
ƒ
ACPI Registers:
This is the constrained part of the hardware interface, described (at least in location) by
the ACPI tables.
ƒ
ACPI BIOS:
This is the code that boots the machine and implements interfaces for sleep, wake, and
some restart operations. The ACPI Description Tables are also provided by the ACPI
BIOS.
The ACPI specification requires the system to support at least one sleep state. The BIOS
supports S0, S1, S4, and S5 states. S1 is considered a sleep state.
Revision 1.0
39
System BIOS
Intel® Entry Server Board SE7230CA1-E TPS
This platform can wake up from S1 state using USB devices in addition to the sources
described below.
The wake-up sources are enabled by the ACPI operating systems with cooperation from the
drivers; the BIOS has no direct control over the wakeup sources when an ACPI operating
system is loaded. The role of the BIOS is limited to describing the wakeup sources to the
operating system and controlling secondary control / status bits via the Differentiated System
Description Table (DSDT).
The S5 state is equivalent to operating system shutdown. No system context is saved when
going into S5.
The OEM Table ID field of ACPI Tables are initialized with the Platform Identification string.
4.4.3
Front Control Panel Support
The platform supports a power button and a reset button on the control panel.
4.4.3.1
Power Button
The BIOS supports a front control panel power button. Pressing the power button initiates a
request, which is forwarded to the ACPI power state machines in the chipset.
4.4.3.2
Reset Button
The platform supports a front control panel reset button. Pressing the reset button initiates a
request to the chipset.
4.4.4
Sleep and Wake Support
4.4.4.1
System Sleep States
The platform supports the following ACPI system sleep states:
ƒ
ƒ
ƒ
ƒ
4.4.4.2
ACPI S0 (working) state
ACPI S1 (sleep) state
ACPI S4 (hibernate) state
ACPI S5 (soft-off) state
Wake Events / SCI Sources
The server board supports the following wake-up sources in the ACPI environment. The
operating system controls enabling and disabling these wake sources:
ƒ
Devices that are connected to all USB ports, such as USB mice and keyboards can
wake the system up from S1 sleep state.
ƒ PCI devices, such as onboard NIC devices, can wake the system from the S4/S5 state.
As required by ACPI specification, the power button can wake the system from S1 state
40
Revision 1.0
Intel® Entry Server Board SE7230CA1-E
5.
Server Management
Server Management
The BIOS supports many standards-based server management features and several proprietary
features.
5.1
Console Redirection
The BIOS supports redirection of both video and keyboard via a serial link (COM port). When
console redirection is enabled, the local (host server) keyboard input and POST video output
are passed both to the local keyboard and video connections, and to the remote console
through the serial link. Keyboard inputs from both sources are considered valid and video is
displayed to both outputs.
As an option, the system can be operated without a host keyboard or monitor attached to the
system and run entirely via the remote console, including BIOS Setup.
5.1.1
Serial Configuration Settings
Both EMP and console redirection require N, 8, 1 mode (no parity, 8-bit data, 1 stop bit).
The BIOS does not require that the splash logo be turned off for console redirection to function.
The BIOS supports multiple consoles, some of which are in graphics mode and some in text
mode. The graphics consoles can display the logo and the text consoles can receive the
redirected text.
Console redirection ends at the beginning of the legacy operating system boot (INT 19h). The
operating system is responsible for continuing the redirection from that point.
5.1.2
Keystroke Mappings
During console redirection, the remote terminal sends keystrokes to the local server. The
remote terminal may be a dumb terminal with a direct connection running a communication
program. The keystroke mappings follow VT-UTF8 format with the following extensions.
5.1.2.1
Setup Alias Keys
The <Del> and <Ctrl>-function key combinations are synonyms for the <F2> or “Setup” key.
They are implemented and documented, but are not to be prompted for in screen messages.
These hot keys are defined for console redirection support, and are not to be implemented for
locally attached keyboards.
5.1.2.2
Standalone <Esc> Key for Headless Operation
The Microsoft Headless Design Guidelines describes a specific implementation for the <Esc>
key as a single standalone keystroke:
ƒ
ƒ
<Esc> followed by a two-second pause must be interpreted as a single escape.
<Esc> followed within two seconds by one or more characters that do not form a
sequence described in this specification must be interpreted as <Esc> plus the character
or characters, not as an escape sequence.
Revision 1.0
41
Intel® Entry Server Board SE7230CA1-E TPS
The escape sequence in the following table is an input sequence. This means it is sent to the
BIOS from the remote terminal.
Table 37. Console Redirection Escape Sequences for Headless Operation
Escape Sequence
<Esc>R<Esc>r<Esc>R
This will implement but will default to “disabled”.
5.1.3
ƒ
ƒ
5.2
Description
Remote Console Reset
Limitations
BIOS Console redirection terminates after an EFI-aware operating system calls EFI Exit
Boot Services. The operating system is responsible for continuing console redirection
after that.
BIOS console redirection is a text console. Graphical data, such as a logo, are not
redirected.
Intel® Active Management Technology (AMT)
Intel Active Management Technology architecture is based on market demand for a platform
management solution that provides remote management capabilities independent of system
power states. The Intel® AMT architecture is centered around the Intel® ICH7R IO controller
and Intel® 82573E Gigabit LAN components. The ICH7R provides an interface to a new SPI
flash device for potential cost savings.
Because Intel® AMT depends on the availability of the Intel® 82573E PCI manageability
functions, the Intel® AMT does not operate with third-party LANs.
The main objectives of Intel AMT are:
ƒ
ƒ
ƒ
ƒ
42
Deployable – Intel® AMT uses existing protocols and services available in today’s IT
networks to minimize cost. Intel® AMT is constrained to the use of DHCP, DNS,
SOAP/XML/HTTP, and TLS; which are available on most IT networks today.
Highly Available – The ability to provide remote management in the event of operating
system or hardware failure. Intel® AMT provides baseline services whenever there is (at
the minimum) auxiliary power available to the platform. Currently, system auxiliary power
is maintained by the main power supply when the system is plugged into the wall. This
will significantly reduce IT expenses for system repair.
OS-Independent Agent – Baseline platform management capabilities that simplify
system management running different operating system types and versions. Intel® AMT
provides common remote management and persistent storage features that run
independently of the operating system.
Secure and Tamper Resistant - Intel® AMT provides access control, data security, and
protection against attacks by using standard security protocols (e.g., TLS) and
application-level security mechanisms. Intel® AMT also provides tamper resistance to
prevent the end-user from removing or disabling remote management service.
Revision 1.0
Intel® Entry Server Board SE7230CA1-E
Server Management
Intel® 82573E is a multi-functional device with an embedded microcontroller for manageability
purposes. Manageability functions of the Intel® 82573E PCI are as follows:
ƒ
ƒ
ƒ
IDE-R – for remote boot and SW installation
Serial Port – for Keyboard and text redirection
KCS – for configuration of the manageability content
The Intel® 82573E controller is a PCI Express* GBit Ethernet endpoint device, the first GbE
controller to support Intel® AMT as the next-generation client manageability architecture. Intel®
82573E provides three PCI functions for management purposes: serial port, IDE, and KCS.
When the Intel® AMT is disabled, the Intel® 82573E controller disables these three PCI
functions. When these management functions are disabled, the functions do not response to
PCI configuration cycles (effectively becoming invisible to software). When Intel® AMT is
enabled, the Intel® 82573E controller enables the PCI functions, which appear to software as
standard PCI devices.
Serial Port Function: The Serial Port function supports redirection of keyboard and POST
messages to a terminal window on a remote console. The keyboard and text redirection enables
the control of the client machine through the network without the need to be physically near that
machine. Text and keyboard redirection allows the remote machine to monitor POST progress
of the client machine and allows the remote machine to control and configure the client by
entering BIOS Setup. The Intel® 82573E controller redirects data from the serial port to the
management console via the LAN; hence, providing Serial Over LAN (SOL) capability.
IDE Function: The IDE function provides IDE-R, an IDE redirection interface that provides
client connection to management console ATA/ATAPI devices. When booting from IDE-R, the
IDE-R interface will send the client’s ATA/ATAPI command to the management console. The
management console responds back to the client. A remote machine can setup diagnostic
software or an operating system installation image and direct the client to boot from IDE-R. The
IDE-R interface is the same as the IDE interface and is compliant with ATA/ATAPI-6
specifications. IDE-R does not conflict with the usage of PXE boot. The system can support
both interfaces and can continue to boot from PXE as with any other boot devices. However,
during a management boot session, the Intel® AMT solution will use IDE-R when remote boot is
required. The devices attached to the IDE-R channel are only visible to software during a
management boot session. During a normal boot session, the IDE-R channel appears as no
device present.
KCS Function: The KCS (Keyboard Controller Style) function provides a physical interface
used to convey messages between the host software and the AMT device. The KCS function
defines a set of memory-mapped IO (MMIO) registers. These MMIO registers follow the usage
model used in the Intel® 8742 Universal Peripheral Interface microcontroller. The term
‘Keyboard Controller Style’ reflects the fact that the Intel® 8742 interface is used as the system
keyboard controller interface in PC architecture computer systems.
The AMT BIOS Extension (AMTx) is provided by Intel and is included in the system BIOS at
build time. The AMTx Module communicates with the Intel® 82573E firmware via the KCS
interface. The AMTx Module collects system hardware configuration via ACPI and the SMBIOS
tables, and sends hardware information to the remote management system via the KCS
interface.
Revision 1.0
43
Intel® Entry Server Board SE7230CA1-E TPS
Table 38. Function List
Function
Intel® 82573E Lan
Vendor ID
0x8086
Device ID
0x108B/0x108C (V/E)
IDE
0x8086
0x108D
Serial Port
0x8086
0x108F
KCS
0x8086
0x108E
5.3
Wired For Management (WFM)
Wired for Management is an industry-wide initiative to increase overall manageability and
reduce total cost of ownership. WFM allows a server to be managed over a network. The
system BIOS supports the System Management BIOS Reference Specification, Version 2.4 to
help higher-level instrumentation software meet the Wired For Management Baseline
Specification, Revision 2.0 requirements.
5.3.1
PXE BIOS Support
The BIOS supports the EFI PXE implementation as specified in Chapter 15 of the Extensible
Firmware Interface Reference Specification, Version 1.1. To utilize this, the user must load the
EFI Simple Network Protocol driver. The UNDI driver is specific to the network controller and
must be included with the network card. The Simple Network Protocol driver can be obtained
from http://developer.intel.com/technology/framework.
The BIOS supports legacy PXE option ROMs in legacy mode and includes the necessary PXE
ROMs in the BIOS image for the onboard controllers. The legacy PXE ROM is required to boot
a non-EFI operating system over the network.
5.4
System Management BIOS (SMBIOS)
The BIOS provides support for the System Management BIOS Reference Specification, Version
2.4 to create a standardized interface for manageable attributes that are expected to be
supported by DMI-enabled computer systems. The BIOS provides this interface via data
structures through which the system attributes are reported. Using SMBIOS, a system
administrator can obtain the types, capabilities, operational status, installation date and other
information about the server components.
5.5
Security
The BIOS provides several security features. This section describes the security features and
operating model.
5.5.1
Operating Model
The following table summarizes the operation of security features supported by the BIOS.
Table 39. Security Features Operating Model
44
Revision 1.0
Intel® Entry Server Board SE7230CA1-E
Mode
Password on
boot
Entry Method /
Event
Power On /
Reset
5.5.2
Password Protection
Server Management
Entry Criteria
Behavior
User password set
and password on
boot enabled in
BIOS Setup.
Secure boot
disabled in BIOS
Setup.
System halts for
user password
before scanning
option ROMs.
The system is
not in secure
mode.
No mouse or
keyboard input is
accepted except
the password.
Exit Criteria
User
password.
Administrator
password.
After Exit
Front control panel
buttons are reenabled.
The server boots
normally. Boot
sequence is
determined by setup
options.
The BIOS uses passwords to prevent unauthorized tampering with the server setup. Both user
and administrator passwords are supported by the BIOS. An Administrator password must be
entered in order to set the user password. The maximum length of a password can be seven
characters. The password cannot have characters other than alphanumeric (a-z, A-Z, 0-9). It is
not case sensitive.
Once set, a password can be cleared by changing it to a null string. Entering the user password
will allow the user to modify the time, date, and user password. Other setup fields can be
modified only if the administrator password is entered. If only one password is set, this
password is required to enter BIOS Setup.
The administrator has control over all fields in BIOS Setup, including the ability to clear the user
password.
If the user or administrator enters an incorrect password three times in a row during the boot
sequence, the system is placed into a halt state. A system reset is required to exit out of the halt
state. This feature makes it difficult to break the password by guessing at it.
5.5.3
Password Clear Jumper
If the user and/or administrator password is lost or forgotten, both passwords may be cleared by
moving the password clear jumper into the clear position. The BIOS determines if the password
clear jumper is in the clear position during BIOS POST and clears any passwords if required.
The password clear jumper must be restored to its original position before a new password can
be set.
Revision 1.0
45
Intel® Entry Server Board SE7230CA1-E TPS
6.
Error Reporting and Handling
Error Reporting and Handling
This chapter defines the following error handling features:
ƒ
ƒ
6.1
Error Handling and Logging
Error Messages and Beep Codes
Error Handling and Logging
This section defines how errors are handled by the system BIOS. In addition, error-logging
techniques are described and beep codes for errors are defined.
6.1.1
Error Sources and Types
One of the major requirements of server management is to correctly and consistently handle
system errors. System errors that can be enabled and disabled individually or as a group can be
categorized as follows:
ƒ
ƒ
ƒ
PCI bus
Memory single- and multi-bit errors
Errors detected during POST, logged as POST errors
The error list that would be logged is as follows:
Table 40. Event List
Event Name
Processor thermal trip of last boot
Description
Processor thermal trip happened on
last boot.
When Error Is Caught
Memory channel A Multi-bit ECC
error
Multi-bit ECC error happened on
DIMM channel A.
POST / Runtime
Memory channel A Single-bit ECC
error
Single-bit ECC error happened on
DIMM channel A.
POST / Runtime
Memory channel B Multi-bit ECC
error
Multi-bit ECC error happened on
DIMM channel B.
POST / Runtime
Memory channel B Single-bit ECC
error
Single-bit ECC error happened on
DIMM channel B.
POST / Runtime
CMOS battery failure
CMOS battery failure or CMOS clear
jumper is set to clear CMOS.
POST
CMOS checksum error
CMOS data crushed
POST
CMOS time not set
CMOS time is not set
POST
POST
Keyboard not found
PS/2 KB is not found during POST
POST
Memory size decrease
Memory size is decreased compared
with last boot
POST
Chassis intrusion detected
Chassis is open
POST
Bad SPD tolerance
Some fields of the DIMM SPD may
not be supported, but could be
tolerated by the Memory Reference
Code.
POST
46
Revision 1.0
Error Reporting and Handling
Intel® Entry Server Board SE7230CA1-E TPS
PCI PERR error
PERR error happens on PCI bus
POST / Runtime
PCI SERR error
SERR error happens on PCI bus
POST / Runtime
6.1.2
Error Logging via SMI Handler
The SMI handler is used to handle and log system level events. The SMI handler pre-processes
all system errors, even those that are normally considered to generate an NMI.
The SMI handler logs the event to NVRAM. For example, the BIOS programs the hardware to
generate a SMI on a single-bit memory error and logs the error in the NVRAM in terms of a
SMBIOS Type 15. After the BIOS finishes logging the error it will assert the NMI if needed.
6.1.2.1
PCI Bus Error
The PCI bus defines two error pins, PERR# and SERR#. These are used for reporting PCI
parity errors and system errors, respectively.
In the case of PERR#, the PCI bus master has the option to retry the offending transaction, or to
report it using SERR#. All other PCI-related errors are reported by SERR#. All PCI-to-PCI
bridges are configured so that they generate SERR# on the primary interface whenever there is
SERR# on the secondary side.
6.1.2.2
PCI Express* Errors
Fatal and critical PCI Express* errors are logged as PCI system errors and are promoted to an
NMI. All non-critical PCI Express errors are logged as PCI parity errors.
6.1.2.3
Memory Errors
The hardware is programmed to generate an SMI on correctable data errors in the memory
array. The SMI handler records the error to the NVRAM. The uncorrectable errors may have
corrupted the contents of SMRAM. The SMI handler will log the error to the NVRAM if the
SMRAM contents are still valid.
6.1.3
SMBIOS Type 15
Errors are logged to the NVRAM in terms of the SMBIOS Type 15 (System Event Log). Please
refer to the SMBIOS Specification, version 2.4 for more detail information. The format of the
records is also defined in the following section.
6.1.4
Logging Format Conventions
The BIOS logs an error into the NVRAM area with the following record format, which is also
defined in the SMBIOS Specification, version 2.3.4.
Revision 1.0
47
Intel® Entry Server Board SE7230CA1-E TPS
Error Reporting and Handling
Table 41. Logging Format Conventions
00h
Offset
Name
EventType
Length
Byte
Description
Specifies the “Type” of event noted in an
event-log entry as defined in table.
01h
Length
Byte
Specifies the byte length of the event
record, including the record’s Type and
Length fields.
02h
Year
Byte
Indicates the time when error is logged.
03h
Month
Byte
04h
Day
Byte
05h
Hour
Byte
06h
Minute
Byte
07h
Second
Byte
08h
EventData1
DWORD
EFI_STATUS_CODE_TYPE
0Ch
EventData2
DWORD
EFI_STATUS_CODE_VALUE
Table 42. Event Type Definition Table
Value
Description
Used by this platform (Y/N)
00h
Reserved
N
01h
Single-bit ECC memory error
Y
02h
Multi-bit ECC memory error
Y
03h
Parity memory error
N
04h
Bus time-out
N
05h
I/O Channel Check
N
06h
Software NMI
N
07h
POST Memory Resize
N
08h
POST Error
Y
09h
PCI Parity Error
Y
0Ah
PCI System Error
Y
0Bh
CPU Failure
N
0Ch
EISA FailSafe Timer time-out
N
0Dh
Correctable memory log disabled
N
0Eh
Logging disabled for a specific Event Type –
too many errors of the same type received in
a short amount of time
N
0Fh
Reserved
N
10h
System Limit Exceeded (e.g. voltage or
temperature threshold exceeded)
Y
11h
Asynchronous hardware timer expired and
issued a system reset
N
12h
System configuration information
N
13h
Hard-disk information
N
14h
System reconfigured
N
15h
Uncorrectable CPU-complex error
N
16h
Log Area Reset/Cleared
Y
17h
System boot. If implemented, this log entry is
guaranteed to be the first one written on any
system boot.
N
48
Revision 1.0
Error Reporting and Handling
Intel® Entry Server Board SE7230CA1-E TPS
18h-7Fh
Unused, available for assignment by
SMBIOS Specification Version 2.3.4.
N
80h-FEh
Available for system- and OEM-specific
assignments
Y
FFh
End-of-log. When an application searches
through the event-log records, the end of the
log is identified when a log record with this
type is found.
Y
For more information about the EFI_STATUS_CODE_TYPE and EFI_STATUS_CODE_VALUE
definitions, refer to “Intel Platform Innovation Framework for EFI Status Codes Specification”,
version 0.92.
The errors are also displayed on the BIOS Setup screen under Server Management / View
EventLog menu in the following format:
EventName (times)
Time of Occurrence
EventName is the same as that shown in the Table 58. It is followed by the number of
occurrences of the same event. The ‘Time of Occurrence’ is the last time the event occurred.
6.2
Error Messages and Error Codes
The system BIOS displays error messages on the video screen. Before video initialization, beep
codes inform the user of errors. POST error codes are logged in the event log. The BIOS
displays POST error codes on the video monitor.
6.2.1
Diagnostic LEDs
During the system boot process, the BIOS executes several platform configuration processes,
each of which is assigned a specific hex POST code number. As each configuration routine is
started, the BIOS will display the POST code on the POST code diagnostic LEDs found on the
back edge of the server board. To assist in troubleshooting a system hang during the POST
process, the diagnostic LEDs can be used to identify the last POST process to be executed.
Each POST code is represented by a combination of colors from the four LEDs. The LEDs are
capable of displaying three colors: green, red, and amber. The POST codes are divided into an
upper nibble and a lower nibble. Each bit in the upper nibble is represented by a red LED and
each bit in the lower nibble is represented by a green LED. If both bits are set in the upper and
lower nibbles then both red and green LEDs are lit, resulting in an amber color. If both bits are
clear, then the LED is off.
In the below example, the BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs
are decoded as follows:
ƒ
Red bits = 1010b = Ah
ƒ
Green bits = 1100b = Ch
Since the red bits correspond to the upper nibble and the green bits correspond to the lower
nibble, the two are concatenated to be ACh.
Revision 1.0
49
Intel® Entry Server Board SE7230CA1-E TPS
Error Reporting and Handling
Table 43. POST Progress Code LED Example
8h
LEDs
ACh
1
Result
Amber
4h
Red
Green
1
2h
Red
0
Green
1h
Red
1
Green
1
Green
0
Red
Red
0
Off
MSB
USB Port
Green
0
LSB
Diagnostic LEDs
USB Port
Back edge of baseboard
MSB
LSB
Figure 6. Location of Diagnostic LEDs on Server Board
6.2.2
POST Code Checkpoints
Table 44. POST Code Checkpoints
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB
LSB
Host Processor
Description
Checkpoint
0x10h
OFF
OFF
OFF
R
Power-on initialization of the host processor (bootstrap processor)
0x11h
OFF
OFF
OFF
A
Host processor cache initialization (including AP)
0x12h
OFF
OFF
G
R
Starting application processor initialization
0x13h
OFF
OFF
G
A
SMM initialization
OFF
OFF
R
G
Initializing a chipset component
0x22h
OFF
OFF
A
OFF
0x23h
OFF
OFF
A
G
0x24h
OFF
G
R
OFF
Programming timing parameters in the memory controller
0x25h
OFF
G
R
G
Configuring memory parameters in the memory controller
0x26h
OFF
G
A
OFF
Optimizing memory controller settings
0x27h
OFF
G
A
G
Initializing memory, such as ECC init
0x28h
G
OFF
R
OFF
OFF
R
OFF
R
Chipset
0x21h
Memory
Reading configuration data from memory (SPD on DIMM)
Detecting presence of memory
Testing memory
PCI Bus
0x50h
50
Enumerating PCI busses
Revision 1.0
Error Reporting and Handling
Intel® Entry Server Board SE7230CA1-E TPS
0x51h
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB
LSB
OFF
R
OFF
A
Allocating resources to PCI busses
0x52h
OFF
R
G
R
Hot Plug PCI controller initialization
0x53h
OFF
R
G
A
Reserved for PCI bus
0x54h
OFF
A
OFF
R
Reserved for PCI bus
0x55h
OFF
A
OFF
A
Reserved for PCI bus
0x56h
OFF
A
G
R
Reserved for PCI bus
0x57h
OFF
A
G
A
Reserved for PCI bus
0x58h
G
R
OFF
R
Resetting USB bus
0x59h
G
R
OFF
A
Reserved for USB devices
Checkpoint
Description
USB
ATA / ATAPI / SATA
0x5Ah
G
R
G
R
Begin PATA / SATA bus initialization
0x5Bh
G
R
G
A
Reserved for ATA
0x5Ch
G
A
OFF
R
Resetting SMBUS
0x5Dh
G
A
OFF
A
Reserved for SMBUS
0x70h
OFF
R
R
R
Resetting the video controller (VGA)
0x71h
OFF
R
R
A
Disabling the video controller (VGA)
0x72h
OFF
R
A
R
Enabling the video controller (VGA)
SMBUS
Local Console
Remote Console
0x78h
G
R
R
R
Resetting the console controller
0x79h
G
R
R
A
Disabling the console controller
0x7Ah
G
R
A
R
Enabling the console controller
Keyboard (PS2 or USB)
0x90h
R
OFF
OFF
R
Resetting the keyboard
0x91h
R
OFF
OFF
A
Disabling the keyboard
0x92h
R
OFF
G
R
Resetting the keyboard
0x93h
R
OFF
G
A
Enabling the keyboard
0x94h
R
G
OFF
R
Clearing keyboard input buffer
0x95h
R
G
OFF
A
Instructing keyboard controller to run Self Test (PS2 only)
Mouse (PS2 or USB)
0x98h
A
OFF
OFF
R
Resetting the mouse
0x99h
A
OFF
OFF
A
Detecting the mouse
0x9Ah
A
OFF
G
R
Detecting the presence of mouse
0x9Bh
A
OFF
G
A
Enabling the mouse
0xB0h
R
OFF
R
R
Resetting fixed media device
0xB1h
R
OFF
R
A
Disabling fixed media device
R
OFF
A
R
Detecting presence of a fixed media device (IDE hard drive detection,
etc.)
R
OFF
A
A
Enabling / configuring a fixed media device
Fixed Media
0xB2h
0xB3h
Removable Media
Revision 1.0
51
Intel® Entry Server Board SE7230CA1-E TPS
Checkpoint
0xB8h
0xB9h
0xBAh
0xBCh
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB
LSB
A
OFF
R
R
Error Reporting and Handling
Description
Resetting removable media device
A
OFF
R
A
Disabling removable media device
A
OFF
A
R
Detecting presence of a removable media device (IDE CDROM
detection, etc.)
A
G
R
R
Enabling / configuring a removable media device
Boot Device Selection
0xD0
R
R
OFF
R
Trying boot device selection
0xD1
R
R
OFF
A
Trying boot device selection
0xD2
R
R
G
R
Trying boot device selection
0xD3
R
R
G
A
Trying boot device selection
0xD4
R
A
OFF
R
Trying boot device selection
0xD5
R
A
OFF
A
Trying boot device selection
0xD6
R
A
G
R
Trying boot device selection
0xD7
R
A
G
A
Trying boot device selection
0xD8
A
R
OFF
R
Trying boot device selection
0xD9
A
R
OFF
A
Trying boot device selection
0XDA
A
R
G
R
Trying boot device selection
0xDB
A
R
G
A
Trying boot device selection
0xDC
A
A
OFF
R
Trying boot device selection
0xDE
A
A
G
R
Trying boot device selection
0xDF
A
A
G
A
Trying boot device selection
Started dispatching an PEIM
Pre-EFI Initialization (PEI) Core
0xE0h
R
R
R
OFF
0xE1h
R
R
R
G
0xE2h
R
R
A
OFF
0xE3h
R
R
A
G
Completed dispatching an PEIM
Initial memory found, configured, and installed correctly
Reserved for initialization module use (PEIM)
Driver eXecution Environment (DXE) Core
0xE4h
R
A
R
OFF
Entered EFI driver execution phase (DXE)
0xE5h
R
A
R
G
Reserved for DXE core use
0xE6h
R
A
A
OFF
Started connecting drivers
0xEBh
A
R
A
G
Started dispatching a driver
0xECh
R
A
A
OFF
Completed dispatching a driver
DXE Drivers
0xE7h
R
A
A
G
0xE8h
A
R
R
OFF
0xE9h
A
R
R
G
0xEAh
A
R
A
OFF
0xEEh
A
A
A
OFF
0xEFh
A
A
A
G
Waiting for user input
Checking password
Entering BIOS setup
Flash Update
Calling Int 19. One beep unless silent boot is enabled.
Reserved for DXE Drivers use
Runtime Phase / EFI Operating System Boot
52
0xF4h
R
A
R
R
Entering Sleep state
0xF5h
R
A
R
A
Exiting Sleep state
Revision 1.0
Error Reporting and Handling
Checkpoint
0xF8h
0xF9h
0xFAh
Intel® Entry Server Board SE7230CA1-E TPS
Diagnostic LED Decoder
G=Green, R=Red, A=Amber
MSB
LSB
Description
A
R
R
R
Operating system has requested EFI to close boot services
(ExitBootServices ( ) has been called)
A
R
R
A
Operating system has switched to virtual address mode
(SetVirtualAddressMap ( ) has been called)
A
R
A
R
Operating system has requested the system to reset (ResetSystem ()
has been called)
Pre-EFI Initialization Module (PEIM) / Recovery
0x30h
OFF
OFF
R
R
Crisis recovery has been initiated because of a user request
0x31h
OFF
OFF
R
A
Crisis recovery has been initiated by software (corrupt flash)
0x34h
OFF
G
R
R
Loading crisis recovery capsule
0x35h
OFF
G
R
A
Handing off control to the crisis recovery capsule
0x3Fh
G
G
A
A
Unable to complete crisis recovery.
6.2.3
POST Error Messages and Handling
Whenever possible, the BIOS will output the current boot progress codes on the video screen.
Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class,
subclass, and operation information. The class and subclass fields point to the type of hardware
that is being initialized. The operation field represents the specific initialization activity. Based on
the data bit availability to display progress codes, a progress code can be customized to fit the
data width. The higher the data bit, the higher the granularity of information that can be sent on
the progress port. The progress codes may be reported by the system BIOS or option ROMs.
The Response column in the following table is divided into two types:
ƒ
•
Pause: The message is displayed in the Error Manager screen, an error may be logged
to the NVRAM, and user input is required to continue. The user can take immediate
corrective action or choose to continue booting.
Halt: The message is displayed in the Error Manager screen, an error is logged to the
NVRAM, and the system cannot boot unless the error is resolved. The user needs to
replace the faulty part and restart the system.
Revision 1.0
53
Intel® Entry Server Board SE7230CA1-E TPS
Error Reporting and Handling
Table 45. POST Error Messages and Handling
Error Code
6.2.4
Error Message
CMOS date / time not set
Response
Pause
Y
Log Error
Configuration cleared by jumper
Pause
Y
Configuration default loaded
Pause
N
Password check failed
Halt
N
PCI resource conflict
Pause
N
Insufficient memory to shadow PCI ROM
Pause
N
Processor thermal trip error on last boot
Pause
Y
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users of error conditions. The beep code is followed by a
user visible code on the POST Progress LEDs.
Table 46. POST Error Beep Codes
Beeps
3
6.2.5
Error Message
Memory error
POST Progress Code
Description
System halted because a fatal error related to the memory
was detected.
POST Error Pause Option
In the event of POST error(s) that are listed as "Pause", the BIOS will enter the error manager
and wait for the user to press an appropriate key before booting the operating system or
entering BIOS Setup.
The user can override this option by setting "POST Error Pause" to "disabled" in the BIOS
Setup main menu page. If the "POST Error Pause" option is set to "disabled", the system will
boot the operating system without user intervention. The default value is set to "enabled".
54
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
7.
Connectors and Jumper Blocks
Connectors and Jumper Blocks
7.1
Power Connectors
The power supply connection is supplied to the system through the 18-pin connector. The
following table defines the pin-outs of the connector.
Table 47. Power Connector Pin-out (J3K1)
Pin
Signal
+3.3VDC
18 AWG Color
Orange
Pin
10
Signal
+3.3VDC
18 AWG Color
Orange
3.3V RS
Orange (24AWG)
11
-12VDC
Blue
2
COM
Black
12
COM
Black
3*
COM
Black
13
PSON#
Green
COM RS
Black (24AWG)
14
+5VDC
Red
+5VDC
Red
15
+12V1
Yellow
5V RS
Red (24AWG)
16
COM
Black
1*
4*
5
5 VSB
Purple
17
COM
Black
6
COM
Black
18
+12V3
Yellow
7
COM
Black
8
+12V1
Yellow
9
+12V2
Yellow
I2C Header
7.2
Table 48. HSBP Header Pin-out (J1C1)
Pin
Signal Name
Description
1
SMB_DATA_5V_BP
Data Line
2
GND
GROUND
3
SMB_CLK_5V_BP
Clock Line
4
GND
GROUND
Revision 1.0
55
Connectors and Jumper Blocks
7.3
Intel® Entry Server Board SE7230CA1-E TPS
Front Panel Connector
A standard SSI 34-pin header is provided to support a system front panel. The header contains
reset, NMI, power control buttons, and LED indicators. The following table details the pin-out of
this header.
Table 49. Front Panel 14-pin Header Pin-out (J4k2)
Signal Name
Power LED Anode
Pin
1
Signal Name
NIC1 Activity LED Anode
Pin
2
Power LED Cathode
3
NIC1 Activity LED Cathode
4
HDD Activity LED Anode
5
NIC2 Activity LED Anode
6
HDD Activity LED Cathode
7
NIC2 Activity LED Cathode
8
Power Switch
9
Reset Switch
10
Power Switch(GND)
11
Reset Switch(GND)
12
Key
13
NC
14
Note: NC (No Connect)
7.4
I/O Connectors
7.4.1
VGA Connector
The following table details the pin-out of the VGA connector. This connector is combined with
the COM1 connector.
Table 50. VGA Connector Pin-out (J3A1)
RED
Signal Name
Pin
B1
Signal Name
Fused VCC (+5V)
Pin
B9
GREEN
B2
GND
B10
BLUE
B3
NC
B11
NC
B4
DDCDAT
B12
GND
B5
HSY
B13
GND
B6
VSY
B14
GND
B7
DDCCLK
B15
GND
B8
Note: NC (No Connect)
56
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
7.4.2
Connectors and Jumper Blocks
NIC Connectors
The Intel® Entry Server Board SE7230CA1-E supports two NIC RJ-45 connectors. The
following tables detail the pin-out of the connector.
Table 51. NIC1-Intel® 82573E (10/100/1000) Connector Pin-out (JA5A1)
Signal Name
P2V5_NIC1
9
Pin
Signal Name
NIC1_MDI3_DP
16
Pin
NIC1_MDI0_DP
10
NIC1_MDI3_DN
17
NIC1_MDI0_DN
11
GND
18
NIC1_MDI1_DP
12
NIC1_LINK_1_N
19
NIC1_MDI1_DN
13
P3V3_AUX
20
NIC1_MDI2_DP
14
NIC1_LINK_0_N
21
NIC1_MDI2_DN
15
NIC1_LINK_2_N
22
Table 52. NIC2- Intel® 82541PI (10/100/1000) Connector Pin-out (JA4A1)
7.4.3
Signal Name
P1V8_NIC_RC
1
Pin
Signal Name
NIC2_MDI3_DN
9
Pin
NIC2_MDI2_DN
2
NIC2_MDI0_DN
10
NIC2_MDI2_DP
3
NIC2_MDI0_DP
11
NIC2_MDI1_DP
4
P1V8_NIC_RC
12
NIC2_MDI1_DN
5
NIC2_LINK1000_N
13
P1V8_NIC_RC
6
NIC2_LINK100_N
14
P1V8_NIC_RC
7
NIC2_ACT_LED_N
15
NIC2_MDI3_DP
8
NIC2_LINK_UP_N
16
SATA Connectors
The Intel® ICH7R integrates a SATA controller with four SATA ports. The pin-out for these four
connectors is listed below.
Table 53. SATA Connector Pin-out (J5C1, J5C2)
Pin
1
7.4.4
Signal Name
GND
2
SATA0_TX_P
3
SATA0_TX_N
4
GND
5
SATA0_RX_N
6
SATA0_RX_P
7
GND
Serial Port Connectors
One serial port is provided on the Intel® Entry Server Board SE7230CA1-E. A standard,
external DB9 serial connector is located on the back edge of the server board to supply a Serial
A interface. This connector is combined with the VGA connector (J3A1). An internal 9-pin
header supplies a Serial B interface.
Revision 1.0
57
Connectors and Jumper Blocks
Intel® Entry Server Board SE7230CA1-E TPS
Table 54. External DB9 Serial A Port Pin-out (J3A1)
Signal Name
DCD
Pin
T1
Signal Name
DSR
Pin
T6
RXD
T2
RTS
T7
TXD
T3
CTS
T8
DTR
T4
RI
T9
GND
T5
Table 55. Internal 9-pin Serial B Port Pin-out (J1C2)
7.4.5
Signal Name
DCD
1
Pin
Signal Name
CTS
6
Pin
DSR
2
DTR
7
RX
3
RI
8
RTS
4
GND
9
TX
5
USB Connector
The following table provides the pin-out for the dual external USB connectors. This connector is
combined with an RJ-45 (connected to NIC1 signals).
Table 56. USB Connectors Pin-out (JA5A1)
Pin
Signal Name
U1
P5V_USB_BP_MJ
U2
USB_BACK5_R_DN
U3
USB_BACK5_R_DP
U4
GND
U5
P5V_USB_BP_MJ
U6
USB_BACK4_R_DN
U7
USB_BACK4_R_DP
U8
GND
A header on the server board provides an option to support two additional USB ports. The pinout of the header is detailed in the following table.
Table 57. Optional USB Connection Header Pin-out (J9F2)
NC
Signal Name
Pin
1
Key
Pin
2
GND
3
GND
4
USB_FRONT1_INDUCTOR_DP
5
USB_FRONT2_INDUCTOR_DP
6
USB_FRONT1_INDUCTOR_DN
7
USB_FRONT2_INDUCTOR_DN
8
USB_FNT_PWR (Fused VCC, +5V /w over current
monitor of both port 1)
9
USB_FNT_PWR (Fused VCC, +5V /w over current
monitor of both port 1)
10
58
Signal Name
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
7.5
Connectors and Jumper Blocks
Fan Headers
There are two general-purpose (system) fan headers (J3K2, J4K1). These fan headers have the
same pin-out and are detailed below.
Table 58. Four-pin Fan Headers Pin-out (J3K2, J4K1)
Pin
1
Signal Name
Ground
Type
Power
2
Fan Power
Power
Fan Power +12VDC
3
Fan Tach
Out
FAN_TACH signal is connected to the Heceta* to monitor the fan
speed.
4
PWM
Control
Pulse Width Modulation – Fan speed Control signal
7.6
7.6.1
Description
GROUND is the power supply ground
Miscellaneous Headers and Connectors
Chassis Intrusion Header
A 1x2 pin header (J3B2) is used in the chassis to support a chassis intrusion switch. The pin-out
definition for this header is found in the following table.
Table 59. Intrusion Cable Connector (J3B2) Pin-out
Pin
7.6.2
1
Signal Name
FP_INTRUDER_HDR_P1(Power)
2
FP_INTRUDER_HDR_N
Back Panel I/O Connectors
Figure 7. Back Panel I/O Connections (not to scale)
Revision 1.0
59
Connectors and Jumper Blocks
Intel® Entry Server Board SE7230CA1-E TPS
7.6.3 POST Code LEDs
Four POST code LEDs display POST code progression activities using hexadecimal format,
read from the least significant bit to the most significant bit.
7.7
Jumper Blocks
This section describes configuration jumper options on the Intel® Entry Server Board
SE7230CA1-E.
7.7.1
Clear CMOS and System Maintenance Mode Jumpers
Both the CMOS Clear and the system maintenance mode jumpers consist of 3-pin headers
(CMOS Clear = J3B1, Config Mode = J1A3) located just beside the Front panel and SATA 1
connectors. The Intel® Entry Server Board SE7230CA1-E provides two 3-pin jumper blocks that
are used to perform clearing of NVRAM and system maintenance mode options. The factory
defaults are set to Normal mode for each function.
The following tables describe each jumper option.
Table 60. System Maintenance Mode (J1A3)
Name
Normal
Pin – Pin
1-2
Function
Normal operation
Description
Allows normal system operation with correct
BIOS settings. System will POST normally.
Config (Maintenance)
2-3
Machine Config Mode
Maintenance mode overrides incorrect BIOS
settings which would otherwise prohibit
normal POST with safe settings for specific
hardware configuration.
Recovery boot
Off
BIOS Recovery Mode
Used to recover from a corrupted BIOS.
Table 61. Clear CMOS Jumper Options (J3B2)
Name
Normal
CMOS Clear
60
Pin – Pin
1-2
2-3
Function
Normal operation
Clears CMOS (NVRAM)
Description
Jumper in normal position allows system to
successfully POST and boot to operating
system environment. BIOS settings are
maintained intact.
Jumper in CLEAR position initiates clear of
NVRAM following POST. System message
confirms CMOS clear operation successful.
This setting enforces default BIOS settings,
which can be changed by entering setup via
F2, then exiting setup via F10 and saving
changes.
Revision 1.0
Absolute Maximum Ratings
8.
Intel® Entry Server Board SE7230CA1-E TPS
Absolute Maximum Ratings
Operating the board at conditions beyond those shown in the following table may cause
permanent damage to the system. The table is provided for stress testing purposes only.
Exposure to absolute maximum rating conditions for extended periods may affect system
reliability.
Table 62. Absolute Maximum Ratings
Operating Temperature
5 °C to 50 °C 1
Storage Temperature
-55 °C to +150 °C
Voltage on any signal with respect to ground
-0.3 V to Vdd + 0.3V 2
3.3 V Supply Voltage with Respect to ground
-0.3 V to 3.63 V
5 V Supply Voltage with Respect to ground
-0.3 V to 5.5 V
Notes:
8.1
1.
Chassis design must provide proper airflow to avoid exceeding the processor maximum case
temperature.
2.
VDD means supply voltage for the device
Mean Time Between Failures (MTBF) Test Results
This section provides results of MTBF testing conducted by an Intel testing facility. MTBF is a
standard measure for the reliability and performance of the board under extreme working
conditions. For the Intel® Entry Server Board SE7230CA1-E, MTBF was measured at 40
degrees Centigrade.
Revision 1.0
61
Intel® Entry Server Board SE7230CA1-E TPS
9.
Design and Environmental Specifications
Design and Environmental Specifications
9.1
Power Budget
The following table shows the power consumed on each supply line for the Intel® Entry Server
Board SE7230CA1-E that is configured with one processor (130W max). This configuration
includes four 1-GB DDR2 DIMMs stacked burst at 90% max. The numbers provided in the table
should be used for reference purposes only. Different hardware configurations will produce
different numbers. The numbers in the table reflect a common usage model operating at higher
than average stress levels.
Table 63. The Board Power Budget
Watts
Functional Unit
Utilization
Server Board Input
Totals
Power Supply Rail Voltages
AMPS
Power
3.3V
5.V
12.V
260W
2.9
13.9
2.8
12V
VRM
12.2
-12v
Units
5VSB
0.05
1.54
Amps
Server Board Discrete
Totals
50%
45W
2.9
0.5
0.00
0.00
0.00
0.04
Amps
Server Board
Converters
Efficiency
40W
0.00
13.4
0.00
12.2
0.00
1.5
Amps
Server Board Config
Totals
175.8W
0.00
0.00
2.8
0.00
0.05
0.00
Amps
System Components
29W
0.00
2.8
3.6
0.00
0.00
0.00
Amps
System Totals
291W
2.9
15.2
4.7
12.2
0.05
1.54
Amps
300W
14A
18A
Max 12V+ 12V
VRM
0.5A
2A
1Amin
1Amin
2Amin
0Amin
1Amin
3.3V / 5V Combined
Power
Power Supply
Requirements – 1U
350W
peak
3.3V/5V Combined
Power
9.2
100W
2Amin
Product Regulatory Compliance
9.2.1
Product Safety Compliance
®
The Intel Entry Server Board SE7230CA1-E complies with the following safety requirements:
ƒ
ƒ
ƒ
ƒ
62
UL60950 – CSA 60950(USA / Canada)
EN60950 (Europe)
IEC60950 (International)
CB Certificate and Report, IEC60950 (report to include all country national deviations)
Revision 1.0
Design and Environmental Specifications
ƒ
9.2.2
Intel® Entry Server Board SE7230CA1-E TPS
CE - Low Voltage Directive 73/23/EEE (Europe)
Product EMC Compliance – Class A Compliance
Note: Legally the product is required to comply with Class A emission requirements as it is
intended for a commercial type market place. Intel targets 10db margin to Class A Limits
The Intel® Entry Server Board SE7230CA1-E has been tested and verified to comply with the
following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel®
host system. For information on compatible host system(s), refer to Intel’s Server Builder Web
site or contact your local Intel representative.
ƒ
ƒ
ƒ
ƒ
ƒ
9.2.3
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
FCC /ICES-003 - Emissions (USA/Canada) Verification
CISPR 22 – Emissions (International)
EN55022 - Emissions (Europe)
CE – EMC Directive 89/336/EEC (Europe)
AS/NZS 3548 Emissions (Australia / New Zealand)
Certifications / Registrations / Declarations
UL Certification (US/Canada)
CB Certification (International)
CE Declaration of Conformity (CENELEC Europe)
FCC/ICES-003 Class A Attestation (USA/Canada)
C-Tick Declaration of Conformity (Australia)
MED Declaration of Conformity (New Zealand)
Revision 1.0
63
Intel® Entry Server Board SE7230CA1-E TPS
9.2.4
Design and Environmental Specifications
Product Regulatory Compliance Markings
This product is marked with the following Product Certification Markings:
Table 64. Product Certification Markings
Regulatory Compliance
Region
UL Mark
USA/Canada
Marking
E139761
CE Mark
Europe
Canada EMC Mark
Canada
C-Tick Mark
Australia
Country of Origin
Exporting Requirements
Model Designation
Regulatory Identification
PB Free Marking
Environmental Requirements
9.3
9.3.1
CANADA ICES-003 CLASS A
MADE IN xxxxx (provided by label not
silkscreen)
Board PB Number will be used for the
Model number
Electromagnetic Compatibility Notices
Industry Canada (ICES-003)
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils
numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Apparelis
Numériques”, NMB-003 édictee par le Ministre Canadian des Communications.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the interference-causing equipment standard entitled: Digital Apparatus,
ICES-003 of the Canadian Department of Communications.
64
Revision 1.0
Design and Environmental Specifications
9.3.2
Intel® Entry Server Board SE7230CA1-E TPS
Europe (CE Declaration of Conformity)
This product has been tested in accordance too, and complies with the Low Voltage Directive
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark
to illustrate its compliance.
9.3.3
Australia / New Zealand
This product has been tested and complies with AS/NZS 3548. The product has been marked
with the C-Tick mark to illustrate compliance.
9.4
Restriction of Hazardous Substances (RoHS)
Intel has a system in place to restrict the use of banned substances in accordance with the
European Directive 2002/95/EC. Compliance is based on declaration that materials banned in
the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an
approved/pending RoHS exemption applies.
Note: RoHS implementing details are not fully defined and may change.
Threshold limits and banned substances are noted below.
ƒ
ƒ
9.5
Quantity limit of 0.1% by mass (1000 PPM) for:
o Lead
o Mercury
o Hexavalent Chromium
o Polybrominated Biphenyls Dipheny Ethers (PBDE)
Quantity limit of 0.01% by mass (100 PPM) for:
o Cadmium
Calculated Mean Time Between Failures (MTBF)
The MTBF (Mean Time Between Failures) for the Intel® Entry Server Board SE7230CA1-E as
configured from the factory is shown in the table below.
Table 65. MTBF Data
Product Code
Intel® Entry Server Board SE7230CA1-E
9.6
Operating Temperature
40 degrees C
Mechanical Specifications
The following figure shows a mechanical drawing of the Intel® Entry Server Board SE7230CA1E.
Revision 1.0
65
Intel® Entry Server Board SE7230CA1-E TPS
Design and Environmental Specifications
Figure 8. Intel® Entry Server Board SE7230CA1-E Mechanical Drawing
66
Revision 1.0
Hardware Monitoring
Intel® Entry Server Board SE7230CA1-E TPS
10. Hardware Monitoring
10.1
Monitored Components
The Intel® Entry Server Board SE7230CA1-E has an integrated Heceta chip that is responsible
for hardware monitoring. The Heceta chip provides basic server hardware monitoring which
alerts a system administrator if a hardware problem occurs on the board. The SMsC*
LP47M182NR has implemented some fan speed control/monitor pins. Below is a table of
monitored headers and sensors on the board.
Table 66. Monitored Components
Voltage
Fan Speed
Item
VCCP (PIN #23)
Heceta*
P12V (PIN #21)
Monitors +12Vin for system +12V supply
Heceta*
2.5V (PIN #22)
Monitors 1.5V Core power
Heceta*
P5V (PIN #20)
Monitors +5V
Heceta*
PWM1 (PIN #24)
N/A
Heceta*
PWM2 (PIN #10)
Controls system fan 1 (J3K2)
Heceta*
PWM3 (PIN #13)
Controls system fan 2 (J4K1)
Heceta*
TACH1 (PIN #11) N/A
Heceta*
TACH2 (PIN #12) Monitors system fan 1 (J3K2)
Heceta*
TACH3 (PIN #9)
Temperature H_THEMP_DA/C
10.1.1
Description
Monitors processor voltage
Monitors system fan 2 (J4K1)
Heceta*
Monitors processor temperature
Heceta*
Fan Speed Control
Figure 9. Fan Speed Control Block Diagram
Revision 1.0
67
Intel® Entry Server Board SE7230CA1-E TPS
10.2
Hardware Monitoring
Chassis Intrusion
The Intel® Entry Server Board SE7230CA1-E supports a chassis security feature that detects if
the chassis cover is removed. This security feature uses a mechanical switch on the chassis
that attaches to the chassis intrusion connector. When the chassis cover is removed, the
mechanical switch is in the open position.
68
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Reference Documents
Glossary
This appendix contains important terms used in the preceding chapters. For ease of use,
numeric entries are listed first (e.g., “82460GX”) with alpha entries following (e.g., “AGP 4x”).
Acronyms are then entered in their respective place, with non-acronyms following.
Term
ACPI
Advanced Configuration and Power Interface
Definition
ANSI
American National Standards Institute
AP
Application Processor
ASIC
Application Specific Integrated Circuit
ASR
Asynchronous Reset
BGA
Ball-grid Array
BIOS
Basic input/output system
Byte
8-bit quantity.
CMOS
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes
of memory, which normally resides on the server board.
DCD
Data Carrier Detect
DMA
Direct Memory Access
DMTF
Distributed management Task Force
ECC
Error Correcting Code
EMC
Electromagnetic Compatibility
EPS
External Product Specification
ESCD
Extended System Configuration Data
FDC
Floppy Disk Controller
FIFO
First-In, First-Out
FRU
Field replaceable unit
GB
1024 MB.
GPIO
General purpose I/O
GUID
Globally Unique ID
Hz
Hertz (1 cycle/second)
HDG
Hardware Design Guide
I2C
Inter-integrated circuit bus
IA
Intel® architecture
ICMB
Intelligent Chassis Management Bus
IERR
Internal error
IMB
Inter Module Bus
IP
Internet Protocol
IRQ
Interrupt Request
ITP
In-target probe
KB
1024 bytes
KCS
Keyboard Controller Style
LAN
Local area network
LBA
Logical Block Address
LCD
Liquid crystal display
LPC
Low pin count
Revision 1.0
69
Term
LSB
Least Significant Bit
Definition
MB
1024 KB
MBE
Multi-Bit Error
Ms
milliseconds
MSB
Most Significant Bit
MTBF
Mean Time Between Failures
Mux
multiplexor
NIC
Network Interface Card
NMI
Non-maskable Interrupt
OEM
Original equipment manufacturer
Ohm
Unit of electrical resistance
PBGA
Pin Ball Grid Array
PERR
Parity Error
PIO
Programmable I/O
PMB
Private Management Bus
PMC
Platform Management Controller
PME
Power Management Event
PnP
Plug and Play
POST
Power-on Self Test
PWM
Pulse-Width Modulator
RAIDIOS
RAID I/O Steering
RAM
Random Access Memory
RI
Ring Indicate
RISC
Reduced instruction set computing
RMCP
Remote Management Control Protocol
ROM
Read Only Memory
RTC
Real Time Clock
SBE
Single-Bit Error
SCI
System Configuration Interrupt
SDR
Sensor Data Record
SDRAM
Synchronous Dynamic RAM
SEL
System event log
SERIRQ
Serialized Interrupt Requests
SERR
System Error
SM
Server Management
SMI
Server management interrupt. SMI is the highest priority nonmaskable interrupt
SMM
System Management Mode
SMS
System Management Software
SNMP
Simple Network Management Protocol
SPD
Serial Presence Detect
SSI
Server Standards Infrastructure
TPS
Technical Product Specification
UART
Universal asynchronous receiver and transmitter
70
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Term
USB
Universal Serial Bus
VGA
Video Graphic Adapter
VID
Voltage Identification
VRM
Voltage Regulator Module
Word
16-bit quantity
ZCR
Zero Channel RAID
Revision 1.0
Reference Documents
Definition
71
References
72
ƒ
Advanced Configuration and Power Interface Specification, Revision 1.0b, February
1999, http://www.acpi.info/
ƒ
Advanced Configuration and Power Interface Specification, Revision 2.0, July 2000,
http://www.acpi.info/
ƒ
Advanced Configuration and Power Interface Specification, Revision 3.0, ,
http://www.acpi.info/
ƒ
BIOS Boot Specification Version 1.01. Compaq Computer Corporation, Phoenix
Technologie Ltd., Intel Corporation. 1996, http://www.phoenix.com/resources/specsbbs101.pdf
ƒ
El Torito CD-ROM Boot Specification, Version 1.0,
http://www.phoenix.com/resources/specs-cdrom.pdf
ƒ
Extensible Firmware Interface Reference Specification, Version 1.1,
http://www.intel.com/technology/efi/index.htm
ƒ
Tiano EFI Shell EPS, Revision 0.10. Intel Corporation, 2002
ƒ
EFI 1.1 Shell Commands Specification, v0.3, Available from: EFI1.1ShellCommands.pdf,
EFI sample implementation, revision 1.10.14.62,
http://developer.intel.com/technology/efi/main_sample.htm
ƒ
IA-32e BIOS Writer's Guide, Revision 0.5, Intel Corporation
ƒ
Platform Management FRU Information Storage Definition v1.0,
http://developer.intel.com/design/servers/ipmi
ƒ
Hardware Design Guide for Microsoft Windows 2000 Server, Version 3.0,
http://www.microsoft.com/whdc/system/platform/pcdesign/desguide/serverdg.mspx#ESB
ƒ
Application Note AP-485: Intel Processor Identification and the CPUID Function,
http://www.intel.com/design/xeon/applnots/241618.htm
ƒ
Intelligent Platform Management Bus Specification, Version 1.0,
http://developer.intel.com/design/servers/ipmi/spec.htm
ƒ
Intelligent Platform Management Interface Specification, Version 1.5,
http://developer.intel.com/design/servers/ipmi/spec.htm
ƒ
Intelligent Platform Management Interface Specification, Version 2.0,
http://developer.intel.com/design/servers/ipmi/spec.htm
ƒ
Multiprocessor Specification, Revision 1.4, May 1997
ƒ
Microsoft Headless Design Guidelines,
http://www.microsoft.com/HWDEV/PLATFORM/server/headless/default.asp
ƒ
PCI Local Bus Specification, Revision 3.0, http://www.pcisig.org/
ƒ
PCI Local Bus Specification, Revision 2.2, http://www.pcisig.org/
Revision 1.0
Intel® Entry Server Board SE7230CA1-E TPS
Reference Documents
ƒ
PCI BIOS Specification, Revision 2.1, http://www.pcisig.org/
ƒ
PCI to PCI Bridge Specification, Revision 1.1, http://www.pcisig.org/
ƒ
PCI Express Base Specification, Revision 1.0a, http://www.pcisig.org/
ƒ
PCI Hot-Plug Specification, Revision 1.1, http://www.pcisig.org/
ƒ
PCI IRQ Routing Table Specification, Revision 1.0, Microsoft Corporation
ƒ
Plug and Play BIOS Specification, Revision 1.0a (relevant portions only),
http://www.microsoft.com/whdc/system/pnppwr/pnp/default.mspx
ƒ
Sahalee Baseboard Management Controller Core External Product Specification for
Silverwood Systems, Intel Corporation
ƒ
System Management BIOS Reference Specification, Version 2.4,
http://www.dmtf.org/standards/smbios
ƒ
ACPI Static Resource Affinity Table, Version 1.2,
http://www.microsoft.com/whdc/hwdev/platform/proc/SRAT.mspx
ƒ
SYSID BIOS Support Interface Requirement Specification, Version 1.2
ƒ
Intel® Platform Innovation Framework for EFI Firmware Volume Specification, Revision
0.9, Intel Corporation, 2004, ftp://download.intel.com/technology/framework/docs/Fv.pdf
ƒ
Universal Host Controller Interface Design Guide,
http://developer.intel.com/design/USB/UHCI11D.htm
ƒ
Universal Serial Bus Revision 1.1 Specification, http://www.usb.org/developers/docs
ƒ
Universal Serial Bus Revision 2.0 Specification, http://www.usb.org/developers/docs
ƒ
Wired For Management Baseline Specification, Revision 2.0,
http://www.intel.com/labs/manage/wfm/wfmspecs.htm
ƒ
DMTF Systems Standard Groups Definition
Revision 1.0
73