TI SN54HC42J

SN54HC42, SN74HC42
4-LINE TO 10-LINE DECODERS (1 of 10)
SCLS091B – DECEMBER 1982 – REVISED MAY 1997
D
D
D
D
SN54HC42 . . . J OR W PACKAGE
SN74HC42 . . . D OR N PACKAGE
(TOP VIEW)
Full Decoding of Input Logic
All Outputs Are High for Invalid BCD
Conditions
Also for Applications as 3-Line to 8-Line
Decoders
Package Options Include Plastic
Small-Outline (D) and Ceramic Flat (W)
Packages, Ceramic Chip Carriers (FK), and
Standard Plastic (N) and Ceramic (J)
300-mil DIPs
0
1
2
3
4
5
6
GND
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
A
B
C
D
9
8
7
description
SN54HC42 . . . FK PACKAGE
(TOP VIEW)
1
0
NC
VCC
A
These monolithic decimal decoders consist of
eight inverters and ten 4-input NAND gates. The
inverters are connected in pairs to make BCD
input data available for decoding by the NAND
gates. Full decoding of valid input logic ensures
that all inputs remain off for all invalid input
conditions.
2
3
NC
4
5
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
B
C
NC
D
9
6
GND
NC
7
8
The SN54HC42 is characterized for operation
over the full military temperature range of –55°C
to 125°C. The SN74HC42 is characterized for
operation from –40°C to 85°C.
4
NC – No internal connection
FUNCTION TABLE
INPUTS
NO
NO.
OUTPUTS
D
C
B
A
0
1
2
3
4
5
6
7
8
9
0
L
L
L
L
L
H
H
H
H
H
H
H
H
H
1
L
L
L
H
H
L
H
H
H
H
H
H
H
H
2
L
L
H
L
H
H
L
H
H
H
H
H
H
H
3
L
L
H
H
H
H
H
L
H
H
H
H
H
H
4
L
H
L
L
H
H
H
H
L
H
H
H
H
H
5
L
H
L
H
H
H
H
H
H
L
H
H
H
H
6
L
H
H
L
H
H
H
H
H
H
L
H
H
H
7
L
H
H
H
H
H
H
H
H
H
H
L
H
H
8
H
L
L
L
H
H
H
H
H
H
H
H
L
H
9
H
L
L
H
H
H
H
H
H
H
H
H
H
L
H
L
H
L
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
L
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
Invalid
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  1997, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54HC42, SN74HC42
4-LINE TO 10-LINE DECODERS (1 of 10)
SCLS091B – DECEMBER 1982 – REVISED MAY 1997
logic symbol†
BCD/DEC
0
1
A
B
C
D
15
14
13
12
2
1
2
4
8
3
4
5
6
7
8
9
1
2
3
4
5
6
7
9
10
11
0
1
2
3
4
5
6
7
8
9
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, N, and W packages.
logic diagram (positive logic)
1
0
15
A
2
1
3
2
4
B
3
14
5
4
6
13
5
C
7
9
12
6
7
D
10
8
11
Pin numbers shown are for the D, J, N, and W packages.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
SN54HC42, SN74HC42
4-LINE TO 10-LINE DECODERS (1 of 10)
SCLS091B – DECEMBER 1982 – REVISED MAY 1997
absolute maximum ratings over operating free-air temperature range†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Package thermal impedance, θJA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace
length of zero.
recommended operating conditions
SN54HC42
VCC
Supply voltage
VIH
High-level input voltage
VCC = 2 V
VCC = 4.5 V
VCC = 6 V
VCC = 2 V
VIL
Low-level input voltage
VI
VO
Input voltage
Output voltage
tt
Input transition (rise and fall) time
TA
SN74HC42
MIN
NOM
MAX
MIN
NOM
MAX
2
5
6
2
5
6
1.5
1.5
3.15
3.15
4.2
4.2
0.5
0
0.5
0
1.35
0
1.35
0
1.8
0
1.8
0
0
0
VCC
VCC
0
VCC
VCC
VCC = 2 V
VCC = 4.5 V
0
1000
0
1000
0
500
0
500
VCC = 6 V
0
400
0
400
–55
125
–40
85
Operating free-air temperature
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
V
0
VCC = 4.5 V
VCC = 6 V
UNIT
V
V
V
ns
°C
3
SN54HC42, SN74HC42
4-LINE TO 10-LINE DECODERS (1 of 10)
SCLS091B – DECEMBER 1982 – REVISED MAY 1997
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
IOH = –20 µA
VOH
VI = VIH or VIL
IOH = –4 mA
IOH = –5.2 mA
IOL = 20 µA
VOL
VI = VIH or VIL
IOL = 4 mA
IOL = 5.2 mA
II
ICC
VI = VCC or 0
VI = VCC or 0,
IO = 0
MIN
TA = 25°C
TYP
MAX
SN74HC42
MIN
MIN
MAX
2V
1.9
1.998
1.9
1.9
4.5 V
4.4
4.499
4.4
4.4
6V
5.9
5.999
5.9
5.9
4.5 V
3.98
4.3
3.7
3.84
6V
5.48
5.8
5.2
MAX
UNIT
V
5.34
2V
0.002
0.1
0.1
0.1
4.5 V
0.001
0.1
0.1
0.1
6V
0.001
0.1
0.1
0.1
4.5 V
0.17
0.26
0.4
0.33
6V
0.15
0.26
0.4
0.33
6V
±0.1
±100
±1000
±1000
nA
8
160
80
µA
3
10
10
10
pF
6V
Ci
SN54HC42
2 V to 6 V
V
switching characteristics over recommended operating free-air temperature range, CL = 50 pF
(unless otherwise noted) (see Figure 1)
TA = 25°C
TYP
MAX
SN54HC42
SN74HC42
MIN
MIN
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC
2V
65
150
225
190
tpd
A, B, C, or D
0–9
4.5 V
18
30
45
38
6V
14
26
38
32
tt
Any
MIN
MAX
MAX
2V
28
75
110
95
4.5 V
8
15
22
19
6V
7
13
19
16
UNIT
ns
ns
operating characteristics, TA = 25°C
PARAMETER
Cpd
4
TEST CONDITIONS
Power dissipation capacitance
No load
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TYP
39
UNIT
pF
SN54HC42, SN74HC42
4-LINE TO 10-LINE DECODERS (1 of 10)
SCLS091B – DECEMBER 1982 – REVISED MAY 1997
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
Test
Point
Input
VCC
50%
50%
0V
CL = 50 pF
(see Note A)
tPLH
In-Phase
Output
LOAD CIRCUIT
50%
10%
tPHL
90%
90%
tr
Input
50%
10%
90%
90%
tr
tPHL
VCC
50%
10% 0 V
Out-of-Phase
Output
90%
tf
VOH
50%
10%
VOL
tf
tPLH
50%
10%
tf
50%
10%
90%
VOH
VOL
tr
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
VOLTAGE WAVEFORM
INPUT RISE AND FALL TIMES
NOTES: A. CL includes probe and test-fixture capacitance.
B. Phase relationships between waveforms were chosen arbitrarily. All input pulses are supplied by generators having the following
characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 6 ns, tf = 6 ns.
C. The outputs are measured one at a time with one input transition per measurement.
D. tPLH and tPHL are the same as tpd.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated