ETC ST004BG6SPRF

MODEL ST • OEM PRESSURE TRANSDUCER
APPLICATIONS
•
PNEUMATIC
EQUIPMENT
•
AIR
COMPRESSORS
•
AIR FILTRATION
MONITORING
•
INDUSTRIAL
CONTROLS
FEATURES
BENEFIT
High value and outstanding performance
Amplified outputs
Reverse polarity protection
Less than 500 microseconds response time
Exceeds CE Heavy Industrial EMC
•
•
•
•
Excellent OEM value
Eliminates cost of external amplifiers
Not damaged by reversed excitation
Accurate high speed measurements
HOW TO ORDER
ST
100
P
G
1
S
P
G
F
Model
F = Fluorosilicone
Range
005
010
015
025
050
100
150
200
250
R25
0R4
0R6
001
1R6
2R5
004
006
BAR
PSI
010
016
Output
G = 4-20 mA
R = 0.5 - 4.5 VDC Regulated
C = 0.5 - 4.5 VDC Ratiometric
Termination
P = Packard
Unit
P = PSI
B = BAR
Reference
G = Gage (PSIG)
V = Vacuum**
Internal
Seal Material
S = Stainless Steel
B = Brass
1 = 1/8-27 NPT
2 = 1/4-18 NPT
6 = G1/4-18 BSP
* The character R replaces the decimal point in fractional pressure ranges.
Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details.
** Vacuum for 015 pressure range, full scale output ST-14.7 PSI.
Port
Material
Pressure
Connection
PRESSURE TRANSDUCER
•
•
•
•
•
ST SERIES
The Model ST pressure transducer combines
Honeywell's proven silicon pressure sensing with
the latest in ASIC technology in a rugged,
industrial package. High value, coupled with
outstanding performance, make this an ideal
transducer for industrial control applications such
as air com-pressors and pneumatic equipment.
Temperature compensated, calibrated, and
amplified, the ST has pressure ranges from 0-5
to 0-250 PSI.
The ST offers three standard output options
for user flexibility, which are as follows: a 0.50
to 4.50 Vdc ratiometric output from 5 Vdc
excitation, a 0.50 to 4.50 Vdc regulated output
from 7 to 35 Vdc excitation, or a 4-20 mA output
from 9.5 - 35 Vdc. TheST transducer delivers
±1.0% full scale accuracy (BFSL) over a wide
temperature range of -40° to 100°C and utilizes
a proven industry standard connector for high
reliability.
ST SERIES
•
PRESSURE TRANSDUCER
TECHNICAL SPECIFICATIONS
RANGES*
DIMENSIONS
5, 10, 15, 25, 50, 100, 150, 200, 250 psig*
0.25, 0.4, 0.6, 1.0, 1.6 , 2.5, 4.0, 6.0, 10.0, 16.0 bar
xx.xx = inches
(xx.x) = mm
PHYSICAL
Proof Pressure
<100 psi (5 bar), 3 X rated range
>100 psi (5 bar), 2 X
Burst Pressure
<100 psi (5 bar), 5 X rated range
>100 psi (5 bar), 3 X
Material in Contact
With Media
300 Series SS or brass,
internal seal, silicon, polyetherimide
Weight
0.73
(19)
0.60 (15)
0.85
(22)
c
1.06
(27)
2.0 oz (57 gm)
ENVIRONMENTAL*
b
Shock
Vibration
1.58 (40)
Not Intended for
Customer use
a
50 g’s peak (5 ms)
Figure 514.2-5, Curve AK, Table 514.2-V, Random
Vibration Test (Overall g rms = 20.7 minimum)
1-1/16 (27) HEX
1/8-27 NPT*
ELECTRICAL*
Voltage
Current
Zero Output
0.5 Vdc
4.0 mA
4.0 Vdc (0.50-4.50 Vdc)
16 mA (4-20 mA)
5 Vdc ±250 mV (7.0 Vdc max.)
7 - 35 Vdc
9.5-35 Vdc
5.0 mA typical
(7.0 mA max.)
N/A
2.0 mA
N/A
Pins
Voltage
Current
20 µA @ zero output
N/A
a
+ Excitation
+ Excitation
b
Output
- Excitation
c
Common
N/C
Full Scale Output*
Excitation
Ratiomentric
Regulated
Supply Current
Source (nominal)
Sink (nominal)
Supply Rejection Ratio
* 1/4-18 NPT and G1/4-18 BSP configurations are both optional.
Contact the factory to discuss other pressure port options.
PIN AND WIRE CODES
90 db
Output Impedance
25 W max.
N/A
PERFORMANCE*
Response Time
EMI/RFI
< 500 microseconds
Exceeds CE heavy industrial
(30v/m radiated 150kHz-1gHz)
Electrical Connection
Packard Metri-Pack™
Packard Metri-Pack connector requires
seperate Packard #12065287 mating connector
Accuracy
±1.0% F.S.O. best fit straight line,
Includes: non-linearity, hysteresis,
non-repeatability. Thermal errors are not included.
Total Error Band
±2% F.S.O. Includes: zero offset error,
span error, thermal effect on zero and thermal effect
on span, non-linearity, hysteresis, non-repeatability
Compensated Operating and
Storage Temperature Range
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
-40° to 100°C
(-40° to 212°F)
NOTES:
* All specifications are measured at 25°C (77°F) and at rated excitation
unless otherwise specified.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
* Meets IEC-68-2 or MIL-STD 810C.
* Contact the factory to discuss other pressure ranges.
Item # 1122300 M.G. 3/01
Sensing and Control
Honeywell
100 Discovery Way
Acton, MA 01720 USA
Tel: (877) 384-1300; Fax: (978) 263-0630
www.honeywell.com/sensing/products/di