BOURNS TISP7125F3SL

*R
oH
V SC
AV ER OM
AI SIO PL
LA N IA
BL S NT
E
TISP7125F3 THRU TISP7180F3,
TISP7240F3 THRU TISP7380F3
MEDIUM & HIGH-VOLTAGE TRIPLE ELEMENT
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Patented Ion-Implanted Breakdown Region
- Precise DC and Dynamic Voltages
V(BO)
VDRM
Device
V
V
D Package (Top View)
‘7125F3
100
125
‘7150F3
120
150
‘7180F3
145
180
‘7240F3
180
240
‘7260F3
200
260
‘7290F3
220
290
‘7320F3
240
320
‘7350F3
275
350
‘7380F3†
270
380
† For new designs use ‘7350F3 instead of ‘7380F3
2/10
8/20
10/160
GR-1089-CORE
IEC 61000-4-5
FCC Part 68
FCC Part 68
ITU-T K.20/21
FCC Part 68
GR-1089-CORE
10/700
10/560
10/1000
8
G
2
7
NU
NC
3
6
NU
R
4
5
G
SL Package (Top View)
Rated for International Surge Wave Shapes
- Single and Simultaneous Impulses
Standard
1
NC - No internal connection.
NU - Non-usable; no external electrical connection should be
made to these pins.
Specified ratings require connection of pins 5 and 8.
Planar Passivated Junctions
- Low Off-State Current.................................<10 µ A
Waveshape
T
NC
T
1
G
2
R
3
MD1XAB
ITSP
Device Symbol
A
190
175
110
T
R
70
50
45
............................................... UL Recognized Component
Description
SD7XAB
G
Terminals T, R and G correspond to the
alternative line designators of A, B and C
The TISP7xxxF3 series are 3-point overvoltage protectors
designed for protecting against metallic (differential mode) and
simultaneous longitudinal (common mode) surges. Each terminal
pair has the same voltage limiting values and surge current
capability. This terminal pair surge capability ensures that the
protector can meet the simultaneous longitudinal surge requirement which is typically twice the metallic surge requirement.
How To Order
Device
Package
TISP7xxxF3
D, Small-outline
TISP7xxxF3
SL, Single-in-line
Carrier
Tape and Reel
Tube
Tube
For Standard
Termination Finish
Order As
For Lead Free
Termination Finish
Order As
TISP7xxxF3DR
TISP7xxxF3D
TISP7xxxF3DR-S
TISP7xxxF3D-S
TISP7xxxF3SL
TISP7xxxF3SL-S
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Description (continued)
Each terminal pair has a symmetrical voltage-triggered thyristor characteristic. Overvoltages are initially clipped by breakdown clamping until
the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on state. This low-voltage on state causes the
current resulting from the overvoltage to be safely diverted through the device. The high crowbar holding current prevents d.c. latchup as the
diverted current subsides.These protectors are guaranteed to voltage limit and withstand the listed lightning surges in both polarities.
These medium and high voltage devices are offered in nine voltage variants to meet a range of battery and ringing voltage requirements. They
are guaranteed to suppress and withstand the listed international lightning surges on any terminal pair. Similar devices with working voltages of
58 V and 66 V are detailed in the TISP7072F3, TISP7082F3 data sheet.
Absolute Maximum Ratings, TA = 25 °C (Unless Otherwise Noted)
Rating
Symbol
Value
Unit
Repetitive peak off-state voltage, 0 °C < TA < 70 °C
‘7125F3
‘7150F3
‘7180F3
‘7240F3
‘7260F3
‘7290F3
‘7320F3
‘7350F3
‘7380F3
VDRM
100
120
145
180
200
220
240
275
270
V
Non-repetitive peak on-state pulse current (see Notes 1 and 2)
1/2 (Gas tube differential transient, 1/2 voltage wave shape)
330
2/10 (Telcordia GR-1089-CORE, 2/10 voltage wave shape)
190
1/20 (ITU-T K.22, 1.2/50 voltage wave shape, 25 Ω resistor)
100
8/20 (IEC 61000-4-5, combination wave generator, 1.2/50 voltage wave shape)
175
10/160 (FCC Part 68, 10/160 voltage wave shape)
IPPSM
4/250 (ITU-T K.20/21, 10/700 voltage wave shape, simultaneous)
0.2/310 (CNET I 31-24, 0.5/700 voltage wave shape)
110
95
70
5/310 (ITU-T K.20/21, 10/700 voltage wave shape, single)
70
5/320 (FCC Part 68, 9/720 voltage wave shape, single)
70
10/560 (FCC Part 68, 10/560 voltage wave shape)
50
10/1000 (Telcordia GR-1089-CORE, 10/1000 voltage wave shape)
45
Non-repetitive peak on-state current, 0 °C < TA < 70 °C (see Notes 1 and 3)
50 Hz, 1 s
D Package
SL Package
Initial rate of rise of on-state current, Linear current ramp, Maximum ramp value < 38 A
Junction temperature
Storage temperature range
A
4.3
7.1
A
diT/dt
250
A/µs
TJ
-65 to +150
°C
Tstg
-65 to +150
°C
ITSM
NOTES: 1. Initially, the TISP ® device must be in thermal equilibrium at the specified TA. The impulse may be repeated after the TISP ® device
returns to its initial conditions. The rated current values may be applied either to the R to G or to the T to G or to the T to R
terminals. Additionally, both R to G and T to G may have their rated current values applied simultaneously (In this case the total
G terminal current will be twice the above rated current values).
2. See Thermal Information for derated IPPSM values 0 °C < TA < 70 °C and Applications Information for details on wave shapes.
3. Above 70 °C, derate ITSM linearly to zero at 150 °C lead temperature.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Electrical Characteristics for all Terminal Pairs, T A = 25 °C (Unless Otherwise Noted)
IDRM
Parameter
Repetitive peak offstate current
Test Conditions
Breakover voltage
dv/dt = ±250 V/ms, RSOURCE = 300 Ω
V(BO)
Impulse breakover
voltage
dv/dt ≤ ±1000 V/µs, Linear voltage ramp,
Maximum ramp value = ±500 V
di/dt = ±20 A/µs, Linear current ramp,
Maximum ramp value = ±10 A
dv/dt
ID
Coff
Breakover current
On-state voltage
Holding current
Critical rate of rise of
off-state voltage
Off-state current
Off-state capacitance
‘7125F3
‘7150F3
‘7180F3
‘7240F3
‘7260F3
‘7290F3
‘7320F3
‘7350F3
‘7380F3
‘7125F3
‘7150F3
‘7180F3
‘7240F3
‘7260F3
‘7290F3
‘7320F3
‘7350F3
‘7380F3
dv/dt = ±250 V/ms, RSOURCE = 300 Ω
IT = ±5 A, tW = 100 µs
IT = ±5 A, di/dt = - /+30 mA/ms
Linear voltage ramp, Maximum ramp value < 0.85VDRM
VD = ±50 V
f = 1 MHz, Vd = 1 V rms, VD = 0
f = 1 MHz,
Vd = 1 V rms, VD = -1 V
f = 1 MHz,
Vd = 1 V rms, VD = -2 V
f = 1 MHz,
Vd = 1 V rms, VD = -5 V
f = 1 MHz,
Vd = 1 V rms, VD = -50 V
f = 1 MHz,
Vd = 1 V rms, VD = -100 V
Max
Unit
±10
µA
±125
±150
±180
±240
±260
±290
±320
±350
±380
±143
±168
±198
±269
±289
±319
±349
±379
±409
±0.8
±5
V
V
±0.15
A
V
A
±5
kV/µs
±0.1
37
31
40
34
36
30
31
24
17
13
14
10
20
17
‘7125 thru ‘7180
‘7240 thru ‘7380
‘7125 thru ‘7180
‘7240 thru ‘7380
‘7125 thru ‘7180
‘7240 thru ‘7380
‘7125 thru ‘7180
‘7240 thru ‘7380
‘7125 thru ‘7180
‘7240 thru ‘7380
‘7125 thru ‘7180
‘7240 thru ‘7380
‘7125 thru ‘7180
‘7240 thru ‘7380
f = 1 MHz, Vd = 1 V rms, VDTR = 0
(see Note 4)
NOTE
Typ
VD = VDRM, 0 °C < TA < 70 °C
V(BO)
I(BO)
VT
IH
Min
±10
48
41
52
44
47
39
40
31
23
17
18
13
27
23
µA
pF
4: Three-terminal guarded measurement, unmeasured terminal voltage bias is zero. First six capacitance values, with bias VD, are
for the R-G and T-G terminals only. The last capacitance value, with bias VDTR, is for the T-R terminals.
Thermal Characteristics
Parameter
RθJA
Junction to free air thermal resistance
Test Conditions
Ptot = 0.8 W, TA = 25 °C
5 cm2, FR4 PCB
Min
Typ
D Package
Max
160
SL Package
135
Unit
°C/W
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Parameter Measurement Information
+i
Quadrant I
ITSP
Switching
Characteristic
ITSM
V(BO)
I(BO)
IH
IDRM
VDRM
-v
VD
ID
ID
VD
VDRM
+v
IDRM
IH
I(BO)
V(BO)
ITSM
Quadrant III
ITSP
Switching
Characteristic
-i
Figure 1. Voltage-Current Characteristic for T and R Terminals
T and G and R and G Measurements are Referenced to the G Terminal
T and R Measurements are Referenced to the R Terminal
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
PMXXAAA
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and G, or T and G Terminals
TISP7125F3 THRU TISP7180F3
OFF-STATE CURRENT
vs
JUNCTION TEMPERATURE
TISP7240F3 THRU TISP7380F3
OFF-STATE CURRENT
vs
JUNCTION TEMPERATURE
TC7MAC
100
10
VD = 50 V
1
0·1
VD = -50 V
ID - Off-State Current - mA
ID - Off-State Current - mA
10
VD = 50 V
1
VD = -50 V
0·1
0·01
0·01
0·001
-25
0
25
50
75
100
125
150
0·001
-25
0
TJ - Junction Temperature - °C
75
100
125
150
NORMALIZED BREAKDOWN VOLTAGES
vs
JUNCTION TEMPERATURE
TC7HAE
Normalized Breakdown Voltages
1.2
V(BO)
V(BR)M
1.0
V(BR)
50
Figure 3.
NORMALIZED BREAKDOWN VOLTAGES
vs
JUNCTION TEMPERATURE
TC7MAE
1.1
25
TJ - Junction Temperature - °C
Figure 2.
Normalized Breakdown Voltages
TC7HAC
100
1.2
1.1
V(BO)
V(BR)M
1.0
V(BR)
Normalized to V(BR)
Normalized to V (BR)
I(BR) = 1 mA and 25 °C
I(BR) = 1 mA and 25 °C
Positive Polarity
Positive Polarity
0.9
0.9
-25
0
25
50
75
100
TJ - Junction Temperature - °C
Figure 4.
125
150
-25
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
Figure 5.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and G, or T and G Terminals
TISP7240F3 THRU TISP7380F3
NORMALIZED BREAKDOWN VOLTAGES
vs
JUNCTION TEMPERATURE
TC7HAF
Normalized Breakdown Voltages
Normalized Breakdown Voltages
TISP7125F3 THRU TISP7180F3
NORMALIZED BREAKDOWN VOLTAGES
vs
JUNCTION TEMPERATURE
TC7MAF
1.2
1.1
1.0
V(BO)
V(BR)M
Normalized to V(BR)
V(BR)
1.2
V(BR)M
1.1
V(BO)
1.0
I(BR) = 1 mA and 25 °C
Negative Polarity
Negative Polarity
0.9
0.9
-25
0
25
50
75
100
125
150
-25
TJ - Junction Temperature - °C
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
Figure 6.
Figure 7.
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
TC7MAL
TC7HAL
100
100
Positive Polarity
IT - On-State Current - A
Positive Polarity
IT - On-State Current - A
Normalized to V(BR)
V(BR)
I(BR) = 1 mA and 25 °C
10
150 °C
10
150 °C
25 °C
25 °C
-40 °C
-40 °C
1
1
1
2
3
4
5
6
7 8 9 10
VT - On-State Voltage - V
Figure 8.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
1
2
3
4
5
VT - On-State Voltage - V
Figure 9.
6
7 8 9 10
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and G, or T and G Terminals
TISP7125F3 THRU TISP7180F3
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
100
TISP7240F3 THRU TISP7380F3
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
TC7MAM
Negative Polarity
IT - On-State Current - A
IT - On-State Current - A
Negative Polarity
10
150 °C
10
25 °C
150 °C
25 °C
-40 °C
-40 °C
1
1
1
2
3
4
5
6
7 8 9 10
1
2
VT - On-State Voltage - V
IH, I(BO) - Holding Current, Breakover Current - A
HOLDING CURRENT & BREAKOVER CURRENT
0.6
0.5
0.4
0.3
0.2
0.1
0
25
50
75
100
TJ - Junction Temperature - °C
Figure 12.
4
5
6
7 8 9 10
Figure 11.
1.0
0.9
0.8
0.7
-25
3
VT - On-State Voltage - V
Figure 10.
IH, I(BO) - Holding Current, Breakover Current - A
TC7HAM
100
125
150
1·0
0·9
0·8
0·7
0·6
HOLDING CURRENT & BREAKOVER CURRENT
vs
JUNCTION TEMPERATURE
TC7HAH
0·5
0·4
0·3
+I(BO)
0·2
IH
-I(BO)
0·1
0·09
0·08
0·07
0·06
-25
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
Figure 13.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and G, or T and G Terminals
TISP7125F3 THRU TISP7180F3
NORMALIZED BREAKOVER VOLTAGE
vs
RATE OF RISE OF PRINCIPLE CURRENT
TC7MAU
TC7HAU
Normalized Breakdown Voltage
1.2
Normalized Breakdown Voltage
TISP7240F3 THRU TISP7380F3
NORMALIZED BREAKOVER VOLTAGE
vs
RATE OF RISE OF PRINCIPLE CURRENT
Positive
1.1
1.2
Positive
1.1
Negative
Negative
1.0
0·001
0·01
0·1
1
10
1.0
0·001
100
di/dt - Rate of Rise of Principle Current - A/µs
0·01
0·1
Figure 14.
10
100
Figure 15.
SURGE CURRENT
vs
DECAY TIME
SURGE CURRENT
vs
DECAY TIME
TC7MAA
1000
Maximum Surge Current - A
1000
Maximum Surge Current - A
1
di/dt - Rate of Rise of Principle Current - A/µs
100
10
TC7HAA
100
10
2
10
100
1000
2
10
100
Decay Time - µs
Decay Time - µs
Figure 16.
Figure 17.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
1000
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and T Terminals
TISP7125F3 THRU TISP7180F3
OFF-STATE CURRENT
vs
JUNCTION TEMPERATURE
100
TC7MAD
100
1
0·1
0·01
1
0·1
0·01
0·001
0·001
-25
0
25
50
75
100
125
150
-25
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
TJ - Junction Temperature - °C
Figure 18.
Figure 19.
NORMALIZED BREAKDOWN VOLTAGES
vs
JUNCTION TEMPERATURE
TC7HAG
Normalized Breakdown Voltages
NORMALIZED BREAKDOWN VOLTAGES
vs
JUNCTION TEMPERATURE
TC7MAG
Normalized Breakdown Voltages
TC7HAD
10
ID - Off-State Current - µA
10
ID - Off-State Current - µA
TISP7240F3 THRU TISP7380F3
OFF-STATE CURRENT
vs
JUNCTION TEMPERATURE
1.2
1.1
V(BO)
1.0 V(BR)M
1.2
1.1
V(BO)
1.0 V(BR)M
V(BR)
V(BR)
0.9
0.9
-25
0
25
50
75
100
125
TJ - Junction Temperature - °C
Figure 20.
150
-25
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
Figure 21.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and T Terminals
TISP7125F3 THRU TISP7180F3
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
TISP7240F3 THRU TISP7380F3
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
TC7MAK
10
150 °C
10
150 °C
25 °C
25 °C
-40 °C
-40 °C
1
1
1
2
3
4
5
6
7 8 9 10
1
2
VT - On-State Voltage - V
0.6
0.5
0.4
I(BO)
0.3
IH
IH, I(BO) - Holding Current, Breakover Current - A
IH, I(BO) - Holding Current, Breakover Current - A
4
5
6
7 8 9 10
Figure 23.
HOLDING CURRENT & BREAKOVER CURRENT
vs
JUNCTION TEMPERATURE
TC7MAJ
0.2
3
VT - On-State Voltage - V
Figure 22.
1.0
0.9
0.8
0.7
TC7HAK
100
IT - On-State Current - A
IT - On-State Current - A
100
1·0
0·9
0·8
0·7
0·6
0·5
HOLDING CURRENT & BREAKOVER CURRENT
vs
JUNCTION TEMPERATURE
TC7HAJ
0·4
0·3
IH
0·2
I(BO)
0·1
0·09
0·08
0·07
0·06
0.1
-25
0
25
50
75
100
125
150
TJ - Junction Temperature - °C
Figure 24.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
-25
0
25
50
75
100
125
TJ - Junction Temperature - °C
Figure 25.
150
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Characteristics - R and T Terminals
TISP7125F3 THRU TISP7180F3
NORMALIZED BREAKOVER VOLTAGE
vs
RATE OF RISE OF PRINCIPLE CURRENT
TC7MAV
1.1
1.0
0·001
1.2
Normalized Breakover Voltage
Normalized Breakover Voltage
1.2
0·01
0·1
1
10
100
di/dt - Rate of Rise of Principle Current - A/µs
Figure 26.
TISP7240F3 THRU TISP7380F3
NORMALIZED BREAKOVER VOLTAGE
vs
RATE OF RISE OF PRINCIPLE CURRENT
TC7HAV
1.1
1.0
0·001
0·01
0·1
1
10
100
di/dt - Rate of Rise of Principle Current - A/µs
Figure 27.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Thermal Information
TISP7240F3 THRU TISP7380F3
MAXIMUM NON-RECURRING 50 Hz CURRENT
vs
CURRENT DURATION
TI7HAA
ITRMS - Maximum Non-Recurrent 50 Hz Current - A
ITRMS - Maximum Non-Recurrent 50 Hz Current - A
TISP7125F3 THRU TISP7180F3
MAXIMUM NON-RECURRING 50 Hz CURRENT
vs
CURRENT DURATION
TI7MAA
VGEN = 250 Vrms
RGEN = 10 to 150 Ω
10
SL Package
D Package
1
0·1
1
10
100
10
1000
SL Package
D Package
1
0·1
1
10
100
t - Current Duration - s
Figure 28.
Figure 29.
100
D Package
10
SL Package
0·01
0·1
1
THERMAL RESPONSE
TI7MAB
ZθJA - Transient Thermal Impedance - °C/W
ZθJA - Transient Thermal Impedance - °C/W
RGEN = 20 to 250 Ω
t - Current Duration - s
THERMAL RESPONSE
1
0·0001 0·001
VGEN = 350 Vrms
10
100
t - Power Pulse Duration - s
Figure 30.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
1000
1000
TI7MAB
100
D Package
10
SL Package
1
0·0001 0·001
0·01
0·1
1
10
t - Power Pulse Duration - s
Figure 31.
100
1000
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Thermal Information
Rating
Symbol
Value
Unit
Non-repetitive peak on-state pulse current, 0 °C < TA < 70 °C (see Notes 5, 6 and 7)
1/2 (Gas tube differential transient, 1/2 voltage wave shape)
320
2/10 (Telcordia GR-1089-CORE, 2/10 voltage wave shape)
175
1/20 (ITU-T K.22, 1.2/50 voltage wave shape, 25 Ω resistor)
90
8/20 (IEC 61000-4-5, combination wave generator, 1.2/50 voltage wave shape)
150
10/160 (FCC Part 68, 10/160 voltage wave shape)
4/250 (ITU-T K.20/21, 10/700 voltage wave shape, dual)
IPPSM
90
70
0.2/310 (CNET I 31-24, 0.5/700 voltage wave shape)
65
5/310 (ITU-T K.20/21, 10/700 voltage wave shape, single)
65
5/320 (FCC Part 68, 9/720 voltage wave shape)
65
10/560 (FCC Part 68, 10/560 voltage wave shape)
45
10/1000 (Telcordia GR-1089-CORE, 10/1000 voltage wave shape)
40
A
NOTES: 5. Initially, the TISP ® device must be in thermal equilibrium at the specified TA . The impulse may be repeated after the TISP ® device
returns to its initial conditions. The rated current values may be applied either to the R to G or to the T to G or to the T to R
terminals. Additionally, both R to G and T to G may have their rated current values applied simultaneously (In this case the total
G terminal current will be twice the above rated current values).
6. See Applications Information for details on wave shapes.
7. Above 70 °C, derate IPPSM linearly to zero at 150 °C lead temperature.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
APPLICATIONS INFORMATION
Deployment
These devices are three terminal overvoltage protectors. They limit the voltage between three points in the circuit. Typically, this would be the
two line conductors and protective ground (Figure 32).
Th3
Th1
Th2
Figure 32. MULTI-POINT PROTECTION
In Figure 32, protective functions Th2 and Th3 limit the maximum voltage between each conductor and ground to their respective ±V(BO)
values. Protective function Th1 limits the maximum voltage between the two conductors to its ±V(BO) value.
Lightning Surge
Wave Shape Notation
Most lightning tests, used for equipment verification, specify a unidirectional sawtooth waveform which has an exponential rise and an
exponential decay. Wave shapes are classified in terms of rise time in microseconds and a decay time in microseconds to 50 % of the maximum
amplitude. The notation used for the wave shape is rise time/decay time, without the microseconds quantity and the “/” between the two values
has no mathematical significance. A 50 A, 5/310 waveform would have a peak current value of 50 A, a rise time of 5 µs and a decay time of
310 µs. The TISP® surge current graph comprehends the wave shapes of commonly used surges.
Generators
There are three categories of surge generator type: single wave shape, combination wave shape and circuit defined. Single wave shape
generators have essentially the same wave shape for the open circuit voltage and short circuit current (e.g. 10/1000 open circuit voltage and
short circuit current). Combination generators have two wave shapes, one for the open circuit voltage and the other for the short circuit current
(e.g. 1.2/50 open circuit voltage and 8/20 short circuit current). Circuit specified generators usually equate to a combination generator,
although typically only the open circuit voltage wave shape is referenced (e.g. a 10/700 open circuit voltage generator typically produces a 5/
310 short circuit current). If the combination or circuit defined generators operate into a finite resistance, the wave shape produced is intermediate between the open circuit and short circuit values.
ITU-T 10/700 Generator
This circuit defined generator is specified in many standards. The descriptions and values are not consistent between standards and it is
important to realize that it is always the same generator being used.
Figure 33 shows the 10/700 generator circuit defined in ITU-T recommendation K.20 (10/96) “Resistibility of telecommunication switching
equipment to overvoltages and overcurrents”. The basic generator comprises of:
Capacitor C1, charged to voltage VC, which is the energy storage element
Switch SW to discharge the capacitor into the output shaping network
Shunt resistor R1, series resistor R2 and shunt capacitor C2 form the output shaping network
Series feed resistor R3 to connect to one line conductor for single surge
Series feed resistor R4 to connect to the other line conductor for dual surging
In the normal single surge equipment test configuration, the unsurged line is grounded. This is shown by the dotted lines in the top drawing of
Figure 33. However, doing this at device test places one terminal pair in parallel with another terminal pair. To check the individual terminal
pairs of the TISP7xxxF3, without any paralleled operation, the unsurged terminal is left unconnected.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
APPLICATIONS INFORMATION
Lightning Surge (continued)
ITU-T 10/700 Generator (continued)
VC
2.8 kV
R3
25 Ω
R2
15 Ω
SW
70 A
5/310
T
C1
20 µF
R1
50 Ω
R
R
70 A
5/310
10/700 GENERATOR - SINGLE TERMINAL PAIR TEST
G
T AND G
TEST
R3
25 Ω
R2
15 Ω
R AND G
TEST
R1
50 Ω
C2
200 nF
R AND T
TEST
95 A
4/250
95 A
4/250
T
C1
20 µF
T
G
R4
25 Ω
SW
R
G
C2
200 nF
VC
5.2 kV
T
R
190 A
4/250
G
10/700 GENERATOR - DUAL TERMINAL PAIR TEST
DUAL
T AND G,
R AND G
TEST
Figure 33.
With the generator output open circuit, when SW closes, C1 discharges through R1. The decay time constant will be C1R1, or 20 x 50 =
1000 µs. For the 50 % voltage decay time, the time constant needs to be multiplied by 0.697, giving 0.697 x 1000 = 697 µs which is rounded to
700 µs.
The output rise time is controlled by the time constant of R2 and C2, which is 15 x 200 = 3000 ns or 3 µs. Virtual voltage rise times are given
by straight line extrapolation through the 30 % and 90 % points of the voltage waveform to zero and 100 %. Mathematically, this is equivalent to
3.24 times the time constant, which gives 3.24 x 3 = 9.73 which is rounded to 10 µs. Thus, the open circuit voltage rises in 10 µs and decays in
700 µs, giving the 10/700 generator its name.
When the overvoltage protector switches, it effectively shorts the generator output via the series 25 Ω resistor. Two short circuit conditions
need to be considered: single output using R3 only (top circuit of Figure 33) and dual output using R3 and R4 (bottom circuit of Figure 33).
For the single test, the series combination of R2 and R3 (15 + 25 = 40 Ω) is in shunt with R 1. This lowers the discharge resistance from 50 Ω to
22.2 Ω, giving a discharge time constant of 444 µs and a 50% current decay time of 309.7 µs, which is rounded to 310 µs.
For the rise time, R2 and R3 are in parallel, reducing the effective source resistance from 15 Ω to 9.38 Ω, giving a time constant of 1.88 µs.
Virtual current rise times are given by straight line extrapolation through the 10 % and 90 % points of the current waveform to zero and 100 %.
Mathematically, this is equivalent to 2.75 times the time constant, which gives 2.75 x 1.88 = 5.15, which is rounded to 5 µs. Thus, the short
circuit current rises in 5 µs and decays in 310 µs, giving the 5/310 wave shape.
The series resistance from C1 to the output is 40 Ω, giving an output conductance of 25 A/kV. For each 1 kV of capacitor charge voltage, 25 A
of output current will result.
For the dual test, the series combination of R2 plus R3 and R4 in parallel (15 + 12.5 = 27.5 Ω) is in shunt with R1. This lowers the discharge
resistance from 50 Ω to 17.7 Ω, giving a discharge time constant of 355 µs and a 50% current decay time of 247 µs, which is rounded to
250 µs.
For the rise time, R2, R3 and R 4 are in parallel, reducing the effective source resistance from 15 Ω to 6.82 Ω, giving a time constant of 1.36 µs,
which gives a current rise time of 2.75 x 1.36 = 3.75, which is rounded to 4 µs. Thus, the short circuit current rises in 4 µs and decays in 250
µs, giving the 4/250 wave shape.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
APPLICATIONS INFORMATION
Lightning Surge (continued)
ITU-T 10/700 Generator (continued)
The series resistance from C1 to an individual output is 2 x 27.5 = 55 Ω, giving an output conductance of 18 A/kV. For each 1 kV of capacitor
charge voltage, 18 A of output current will result.
At 25 °C, these protectors are rated at 70 A for the single terminal pair condition and 95 A for the dual condition (R and G terminals and T and
G terminals). In terms of generator voltage, this gives a maximum generator setting of 70 x 40 = 2.8 kV for the single condition and 2 x 95 x
27.5 = 5.2 kV for the dual condition. The higher generator voltage setting for the dual condition is due to the current waveform decay being
shorter at 250 µs compared to the 310 µs value of the single condition.
Other ITU-T recommendations use the 10/700 generator: K.17 (11/88) “Tests on power-fed repeaters using solid-state devices in order to
check the arrangements for protection from external interference” and K.21(10/96) “Resistibility of subscriber’s terminal to overvoltages and
overcurrents”, K.30 (03/93) “Positive temperature coefficient (PTC) thermistors”.
Several IEC publications use the 10/700 generator; common ones are IEC 6100-4-5 (03/95) “Electromagnetic compatibility (EMC) - Part 4:
Testing and measurement techniques - Section 5: Surge immunity test” and IEC 60950 (04/ 99) “Safety of information technology equipment”.
The IEC 60950 10/700 generator is carried through into other “950” derivatives. Europe is harmonized by CENELEC (Comité Européen de
Normalization Electro-technique) under EN 60950 (included in the Low Voltage Directive, CE mark). US has UL (Underwriters Laboratories)
1950 and Canada CSA (Canadian Standards Authority) C22.2 No. 950.
FCC Part 68 “Connection of terminal equipment to the telephone network” (47 CFR 68) uses the 10/700 generator for Type B surge testing.
Part 68 defines the open circuit voltage wave shape as 9/720 and the short circuit current wave shape as 5/320 for a single output. The current
wave shape in the dual (longitudinal) test condition is not defined, but it can be assumed to be 4/250.
Several VDE publications use the 10/700 generator, for example: VDE 0878 Part 200 (12/92) ”Electromagnetic compatibility of information
technology equipment and telecommunications equipment; Immunity of analogue subscriber equipment”.
1.2/50 Generators
The 1.2/50 open circuit voltage and 8/20 short circuit current combination generator is defined in IEC 61000-4-5 (03/95) “Electromagnetic
compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test”. This generator has a fictive output
resistance of 2 Ω, meaning that dividing the open circuit output voltage by the short circuit output current gives a value of 2 Ω(500 A/kV).
The combination generator has three testing configurations; directly applied for testing between equipment a.c. supply connections, applied
via an external 10 Ω resistor for testing between the a.c. supply connections and ground, and applied via an external 40 Ω resistor for testing
all other lines. For unshielded unsymmetrical data or signalling lines, the combination generator is applied via a 40 Ω resistor either between
lines or line to ground. For unshielded symmetrical telecommunication lines, the combination generator is applied to all lines via a resistor of
n x 40 Ω, where n is the number of conductors and the maximum value of external feed resistance is 250 Ω. Thus, for four conductors, n = 4
and the series resistance is 4 x 40 = 160 Ω. For ten conductors, the resistance cannot be 10 x 40 = 400 Ω and must be 250 Ω. The combination generator is used for short distance lines; long distance lines are tested with the 10/700 generator.
When the combination generator is used with a 40 Ω, or more, external resistor, the current wave shape is not 8/20, but becomes closer to the
open circuit voltage wave shape of 1.2/50. For example, a commercial generator when used with 40 Ω produced an 1.4/50 wave shape.
The wave shapes of 1.2/50 and 8/20 occur in other generators as well. British Telecommunication has a combination generator with 1.2/50
voltage and 8/20 current wave shapes, but it has a fictive resistance of 1 Ω. ITU-T recommendation K.22 “Overvoltage resistibility of equipment connected to an ISDN T/S BUS” (05/95) has a 1.2/50 generator option using only resistive and capacitive elements, Figure 34.
The K.22 generator produces a 1.4/53 open circuit voltage wave. Using 25 Ω output resistors, gives a single short circuit current output wave
shape of 0.8/18 with 26 A/kV and a dual of 0.6/13 with 20 A/kV. These current wave shapes are often rounded to 1/20 and 0.8/14.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
APPLICATIONS INFORMATION
Lightning Surge (continued)
1.2/50 Generators (continued)
C4
8 nF
VC
1 kV
C1
1 µF
R2
13 Ω
SW
R1
76 Ω
C3
8 nF
C2
30 nF
NOTE: SOME STANDARDS
REPLACE OUTPUT
CAPACITORS WITH
25 Ω RESISTORS
K.22 1.2/50 GENERATOR
Figure 34.
There are 8/20 short circuit current defined generators. These are usually very high current, 10 kA or more and are used for testing a.c.
protectors, primary protection modules and some Gas Discharge Tubes.
Impulse Testing
To verify the withstand capability and safety of the equipment, standards require that the equipment is tested with various impulse wave forms.
The table in this section shows some common test values.
Manufacturers are being increasingly required to design in protection coordination. This means that each protector is operated at its design
level and currents are diverted through the appropriate protector, e.g. the primary level current through the primary protector and lower levels
of current may be diverted through the secondary or inherent equipment protection. Without coordination, primary level currents could pass
through the equipment only designed to pass secondary level currents. To ensure coordination happens with fixed voltage protectors, some
resistance is normally used between the primary and secondary protection (R1a and R1b, Figure 36). The values given in this data sheet apply
to a 400 V (d.c. sparkover) gas discharge tube primary protector and the appropriate test voltage when the equipment is tested with a primary
protector.
Voltage
Peak Current
Current
TISP7xxxF3
Series
Value
Waveform
25 °C Rating
Resistance
Waveform
A
µs
A
Ω
µs
2500
2/10
2 x 500
2/10
2 x 190
GR-1089-CORE
12
1000
10/1000
2 x 100
10/1000
2 x 45
1500
10/160
200
10/160
110
6
800
10/560
100
10/560
50
8
FCC Part 68
1000
9/720 †
25
5/320 †
70
(March 1998)
1500
(SINGLE)
37.5
5/320 †
70
0
1500
(DUAL)
2 x 27
4/250
2 x 95
I 31-24
1500
0.5/700
37.5
0.2/310
70
0
0
70
5/310
25
10/700
1000
0
70
5/310
37.5
(SINGLE)
1500
ITU-T K.20/K.21
17
70
5/310
100
(SINGLE)
4000
0
2 x 95
4/250
2 x 72
(DUAL)
4000
† FCC Part 68 terminology for the waveforms produced by the ITU-T recommendation K.21 10/700 impulse generator
NA = Not Applicable, primary protection removed or not specified.
Standard
Peak Voltage
Setting
V
Coordination
Resistance
Ω (Min.)
NA
NA
NA
NA
NA
6
6
If the impulse generator current exceeds the protector’s current rating, then a series resistance can be used to reduce the current to the
protector’s rated value to prevent possible failure. The required value of series resistance for a given waveform is given by the following
calculations. First, the minimum total circuit impedance is found by dividing the impulse generator’s peak voltage by the protector’s rated
current. The impulse generator’s fictive impedance (generator’s peak voltage divided by peak short circuit current) is then subtracted from the
minimum total circuit impedance to give the required value of series resistance. In some cases, the equipment will require verification over a
temperature range. By using the derated waveform values from the thermal information section, the appropriate series resistor value can be
calculated for ambient temperatures in the range of 0 °C to 70 °C.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
APPLICATIONS INFORMATION
Protection Voltage
The protection voltage, (V(BO) ), increases under lightning surge conditions due to thyristor regeneration. This increase is dependent on the
rate of current rise, di/dt, when the TISP® device is clamping the voltage in its breakdown region. The V(BO) value under surge conditions can
be estimated by multiplying the 50 Hz rate V(BO) (250 V/ms) value by the normalized increase at the surge’s di/dt. An estimate of the di/dt can
be made from the surge generator voltage rate of rise, dv/dt, and the circuit resistance.
As an example, the ITU-T recommendation K.21 1.5 kV, 10/700 surge has an average dv/dt of 150 V/µs, but, as the rise is exponential, the
initial dv/dt is three times higher, being 450 V/µs. The instantaneous generator output resistance is 25 Ω. If the equipment has an additional
series resistance of 20 Ω, the total series resistance becomes 45 Ω. The maximum di/dt then can be estimated as 450/45 = 10 A/µs. In
practice, the measured di/dt and protection voltage increase will be lower due to inductive effects and the finite slope resistance of the TISP®
breakdown region.
Capacitance
Off-State Capacitance
The off-state capacitance of a TISP® device is sensitive to junction temperature, TJ, and the bias voltage, comprising of the dc voltage, VD,
and the ac voltage, Vd. All the capacitance values in this data sheet are measured with an ac voltage of 1 Vrms. When VD >> Vd, the capacitance value is independent on the value of Vd. Up to 10 MHz, the capacitance is essentially independent of frequency. Above 10 MHz, the
effective capacitance is strongly dependent on connection inductance. For example, a printed wiring (PW) trace of 10 cm could create a circuit
resonance with the device capacitance in the region of 80 MHz.
Longitudinal Balance
Figure 35 shows a three terminal TISP® device with its equivalent “delta” capacitance. Each capacitance, CTG , CRG and CTR, is the true
terminal pair capacitance measured with a three terminal or guarded capacitance bridge. If wire R is biased at a larger potential than wire T,
then CTG > CRG. Capacitance CTG is equivalent to a capacitance of CRG in parallel with the capacitive difference of (CTG -C RG). The line
capacitive unbalance is due to (CTG -CRG) and the capacitance shunting the line is CTR +CRG/2 .
Figure 35.
All capacitance measurements in this data sheet are three terminal guarded to allow the designer to accurately assess capacitive unbalance
effects. Simple two terminal capacitance meters (unguarded third terminal) give false readings as the shunt capacitance via the third terminal is
included.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP7xxxF3 (MV, HV) Overvoltage Protector Series
Typical Circuits
TIP
WIRE
F1a
R1a
Th3
GDTa
PROTECTED
EQUIPMENT
Th1
GDTb
Th2
F1b
R1b
RING
WIRE
AI7XBP
TISP7xxxF3
Figure 36. Protection Module
R1a
Th3
SIGNAL
Th1
Th2
R1b
AI7XBM
TISP7150F3
D.C.
Figure 37. ISDN Protection
OVERCURRENT
PROTECTION
TIP
WIRE
RING/TEST
PROTECTION
TEST
RELAY
RING
RELAY
S3a
R1a
COORDINATION
RESISTANCE
SLIC
RELAY
Th3
S1a
SLIC
PROTECTION
Th4
S2a
Th1
SLIC
Th2
RING
WIRE
Th5
R1b
S3b
TISP7xxxF3
S1b
S2b
TISP6xxxx,
TISPPBLx,
1/2TISP6NTP2
C1
220 nF
TEST
EQUIPMENT
RING
GENERATOR
VBAT
AI7XBN
Figure 38. Line Card Ring/Test Protection
“TISP” is a trademark of Bourns, Ltd., a Bourns Company, and is Registered in U.S. Patent and Trademark Office.
“Bourns” is a registered trademark of Bourns, Inc. in the U.S. and other countries.
MARCH 1994 - REVISED MARCH 2006
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.