TKD SERIES - 50 WATT, 3/4 BRICK DESCRIPTION The TKD series of dual-output DC/DC converters provides high power and full isolation in a low cost, single-board design package. The TKD series provides highly reliable, onboard conversion of telecom and datacom input voltages to isolated low output voltages without the need for a heatsink. The TKD series is ideally suited for Distributed Power Architectures (DPA), telecommunications equipment, LAN/WAN, and data processing applications. FEATURES • • • • • • • • • TECHNICAL SPECIFICATIONS Input Parameter Maximum Unit Voltage Range 48 nom. Transient Voltage Withstand 36-75 VDC 100/100 V/ms Turn-on Time 25 mS Input Reflected Ripple Current 50 mApk-pk 34/30 Von/Voff UVP Trip Range Efficiency vs. Output 90.0% Maximum Unit ±1.5 % Vout 0.5 % Vout 0.5 % Vout 1 A Pk Deviation 4 % Vout Settling Time 500 µS Output 1 2.50-3.47 V Output 2 if Vout1 set to 3.3V 1.50-2.50 V Output 2 if Vout1 set to 2.5V 1.50-2.00 V Power Limit Threshold Range 110-150 % Pout rated OVP Trip Range 115-140 % Vout Setpoint Accuracy Line Reg. Vin min. – Vin max., Iout rated output 1 Load Reg. Iout min. – Iout max., Vin rated output 1 Min. Output Current, each Output Efficiency Output Parameter Independent Dual Outputs Low Cost Package No Heatsink Single-Board Design Wide Trim Range for both Outputs 1500V Isolation Industry Standard Footprint Remote Shutdown Flexible Output Power 80.0% VIN=36V 70.0% VIN=48V 60.0% VIN=75V 50.0% 0.80 1.60 2.40 3.20 4.00 4.80 5.60 6.40 7.20 8.00 Dynamic Reg., Loadstep Iout1 = Iout2 (A) Voltage Trim Range General Parameter Maximum Unit 200 KHz Positive On>3.5/Off<1.8 V Negative (optional) On<1.8/Off>3.5 V Isolation Input-Output 1500 VDC Temp. Coefficient 0.03 %/ C Switching Frequency Remote ON/OFF ° Board Temp Notes Operating Range -40 to +100 ° Storage Range -40 to +125 ° 105 to 115 ° Thermal Shutdown Range Specifications typically at 25°C, nominal line, and full load unless otherwise stated. Humidity max, Non-Condensing Safety Specifications subject to change without notice. Weight (approx) REV. 08/01 1 95 C C C % Pending 1.5 Oz. TKD SERIES - 50 WATT, 3/4 BRICK MODELS - (See the last page of section for options.) MODEL TKD12ZED-T NOTES: INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS)** 48 36-75 2.0 3.3/2.5 12/12 RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY*** 100/100 84% * Maximum input current at minimum input voltage, maximum rated output power. ** Maximum current on either output not to exceed Iout rated and total output power not to exceed 50 Watts. *** At nominal Vin, output current equal to 8.0 Amps on either output. MECHANICAL DRAWING 3.90 (99.1) 1 +Vin 2 -Vin 3 On/Off 4 +Vout2 5 +Vout2 6 Common 7 Common 8 +Vout1 9 +Vout1 10 Trim 2 11 Trim 1 1.0 (25.40) 1 2 3 2.36 0.8 (20.32) (60.0) 0.6 (15.24) Bottom View 1.40 (35.56) 1.20 (30.48) 1.00 (25.40) 0.80 (20.32) 0.60 (15.24) 0.40 (10.16) 0.20 (5.08) 0 0.385 (9.80) 0 0.10 (2.50) Function 3.70 (93.98) PIN 4 5 6 7 8 9 10 11 0.40 (1.02) 0.18 (4.60) 0.45 (11.40) Side View Units: inches (mm) 2 OPTIONS ! !-. ' ' ' ' ' . " ' 0 2 3 4 5 7007) 28 6 ! 70;7) 38 6 ! 724) 90 "= "> 8 < 0" 724) 90 @ "> 0@ 74;) 004 "= "> 74;) 004 @ "> 2" 7<;) 240 "= "> 7<;) 240 @ "> 3" 2@ 3@ "# "$% "$ " "! ! &$ & &! ' '&% "# "$% "$ " "! &$ & &! / /% /' 1# ! 1#% 1# ! * 1# ! * 1 + # : * # : * # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> ''! (!) ' * + ''! (" ) ' * +,, 6 ! 7087) 49 1 ' 6 1 ' 6 1 ' 6 1 ' 6 1 ' 6 1 ' 6 +A "$7;7BC-#'3@ D "$7;7BC-# !- 7<;) > !70;5E-3 D !70;5E &$799BC-#'8 D &$799BC-# ! 7007) NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 3