TRUMPOWER TMP150-27

TRUMPower
150 WATT MEDICAL POWER ADAPTERS
D E S C R IP T IO N
TMP150 SERIES
The TMP150 is a series of medical grade, class I
and class II, AC/DC desktop power adapters of 132
to 150 watts output power. They are enclosed in a
94V-1 rated case with an IEC 320/C14 or IEC
320/C18 AC inlet to mate with interchangeable cord
for world-wide use. All models meet CISPR 11 and
FCC class B emission limits, and are designed for
medical applications.
Class I, Class II
( LV D )
RoHS
F E AT U R E S
‧
‧
‧
‧
‧
‧
‧
Low safety ground leakage current
Optional output connectors
100% burn-in
9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e
O v e r v o l ta g e & o v e r c u r r e n t p r o t e c t i o n s
0.98 PFC
C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y
l e v e l I V r e q u i r e m e n ts
‧ No load consumption less than 0.5W
‧ Av e r a g e a c t i v e e f f i c i e n c y ≧ 8 5 %
‧ C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
S a f e t y Sta n d a r d A p p r o va l s :
UL 60601-1
CSA C22.2 No. 601.1
TÜV EN60601-1
I N P U T S P E C I F I C AT I O N S
I n p u t v o l ta g e :
Input frequency:
Input current:
90 to 264VAC
47 to 63Hz
2.0A (rms) for 115VAC
1.0A (rms) for 230VAC
Earth leakage current:
90µA max. @ 115VAC, 60Hz
150µA max. @ 230VAC, 50Hz
(Class I)
E n c l o s u r e l e a k a g e c u r r e n t : 90µA max. @ 264VAC, 50Hz
(Class II)
Overcurrent protection:
Temperature coefficient:
Transient response:
See rating chart
See rating chart
2% peak to peak maximum
Set at 112 – 140% of its nominal
output voltage
All outputs protected to short
circuit conditions
All outputs ±0.04%/ºC maximum
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Switching frequency: 30KHz ~ 110KHz
Power factor:
Efficiency:
Hold-up time:
Line regulation:
0.98 typical at 115VAC
85% min.
15 msec minimum at 110VAC
±0.5% maximum at full load
Inrush current:
60 amps @ 115VAC or 100 amps
@ 230VAC, at 25ºC cold start
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
150,000 hours minimum at full load
At 25ºC ambient, calculated per
MIL-HDBK-217F
Withstand voltage:
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
Overvoltage protection:
GENERAL SPECIFICATIONS
0 ºC t o + 6 0 ºC
- 4 0 ºC t o + 8 5 º C
5% to 95% non-condensing
Derate from 100% at +40ºC linearly
to 50% at +60ºC
MTBF:
EMC Performance
E N 5 5 0 11 :
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Harmonic distortion, Class D
Line flicker
ESD, ±8KV air and ±6KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ±2KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 3A/m
E N 6 1 0 0 0 - 4 - 11 :
Voltage dips, 30% reduction for
500ms, 60% reduction for 100ms
and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
MEDICAL GRADE
TMP150 SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Product No.
Vnom.
Imin.
Imax.
Tol.
Maximum
Output Power
TMP150-12
TMP150-15
12.0V
15.0V
0A
0A
11.0A
9.0A
5%
5%
135W
TMP150-19
19.0V
0A
7.90A
5%
150W
TMP150-24
24.0V
0A
6.25A
5%
150W
TMP150-27
27.0V
0A
5.56A
5%
150W
TMP150-48
48.0V
0A
3.13A
5%
150W
Output
NOTES:
132W
1. Ripple and noise : Peak-to-peak with 20MHz bandwidth and 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor at
rated line voltage and load ranges.
2. To order a “Class II” model with IEC320/C18 inlet, add suffix “C2”, e.g. TMP150-24-C2.
MECHANICAL SPECIFICATIONS
*Add suffix “C2” when ordering “Class II” units with
IEC 320/C18 inlet.
NOTES:
1.
Dimensions show in inch [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Weight: 960 grams approx.
4.
Standard output connector is a male 4-pin power DIN. Please consult TRUMPower for other connector options.
5.
TMP150-12, -15, -19 output connectors are without lock. TMP150-24, -27, -48 output connectors are with lock.
PIN CHART
PIN
Product No.
TMP150-12
TMP150-19
TMP150-27
TMP150-15
TMP150-24
TMP150-48
1
2
3
4
Shell
Return
Output +V
Return
Output +V
AC Ground
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com