TRUMPower 150 WATT MEDICAL POWER ADAPTERS D E S C R IP T IO N TMP150 SERIES The TMP150 is a series of medical grade, class I and class II, AC/DC desktop power adapters of 132 to 150 watts output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or IEC 320/C18 AC inlet to mate with interchangeable cord for world-wide use. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications. Class I, Class II ( LV D ) RoHS F E AT U R E S ‧ ‧ ‧ ‧ ‧ ‧ ‧ Low safety ground leakage current Optional output connectors 100% burn-in 9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e O v e r v o l ta g e & o v e r c u r r e n t p r o t e c t i o n s 0.98 PFC C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y l e v e l I V r e q u i r e m e n ts ‧ No load consumption less than 0.5W ‧ Av e r a g e a c t i v e e f f i c i e n c y ≧ 8 5 % ‧ C o m p l i a n t w i t h R o H S r e q u i r e m e n ts S a f e t y Sta n d a r d A p p r o va l s : UL 60601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 I N P U T S P E C I F I C AT I O N S I n p u t v o l ta g e : Input frequency: Input current: 90 to 264VAC 47 to 63Hz 2.0A (rms) for 115VAC 1.0A (rms) for 230VAC Earth leakage current: 90µA max. @ 115VAC, 60Hz 150µA max. @ 230VAC, 50Hz (Class I) E n c l o s u r e l e a k a g e c u r r e n t : 90µA max. @ 264VAC, 50Hz (Class II) Overcurrent protection: Temperature coefficient: Transient response: See rating chart See rating chart 2% peak to peak maximum Set at 112 – 140% of its nominal output voltage All outputs protected to short circuit conditions All outputs ±0.04%/ºC maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change E N V I R O N M E N TA L S P E C I F I C AT I O N S Operating temperature: Storage temperature: Relative humidity: Derating: Switching frequency: 30KHz ~ 110KHz Power factor: Efficiency: Hold-up time: Line regulation: 0.98 typical at 115VAC 85% min. 15 msec minimum at 110VAC ±0.5% maximum at full load Inrush current: 60 amps @ 115VAC or 100 amps @ 230VAC, at 25ºC cold start 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground 150,000 hours minimum at full load At 25ºC ambient, calculated per MIL-HDBK-217F Withstand voltage: OUTPUT SPECIFICATIONS Output voltage/current: Total output power: Ripple and noise: Overvoltage protection: GENERAL SPECIFICATIONS 0 ºC t o + 6 0 ºC - 4 0 ºC t o + 8 5 º C 5% to 95% non-condensing Derate from 100% at +40ºC linearly to 50% at +60ºC MTBF: EMC Performance E N 5 5 0 11 : FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: Class B conducted, Class B radiated Class B conducted, Class B radiated Class B conducted, Class B radiated Harmonic distortion, Class D Line flicker ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com MEDICAL GRADE TMP150 SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Product No. Vnom. Imin. Imax. Tol. Maximum Output Power TMP150-12 TMP150-15 12.0V 15.0V 0A 0A 11.0A 9.0A 5% 5% 135W TMP150-19 19.0V 0A 7.90A 5% 150W TMP150-24 24.0V 0A 6.25A 5% 150W TMP150-27 27.0V 0A 5.56A 5% 150W TMP150-48 48.0V 0A 3.13A 5% 150W Output NOTES: 132W 1. Ripple and noise : Peak-to-peak with 20MHz bandwidth and 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor at rated line voltage and load ranges. 2. To order a “Class II” model with IEC320/C18 inlet, add suffix “C2”, e.g. TMP150-24-C2. MECHANICAL SPECIFICATIONS *Add suffix “C2” when ordering “Class II” units with IEC 320/C18 inlet. NOTES: 1. Dimensions show in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 960 grams approx. 4. Standard output connector is a male 4-pin power DIN. Please consult TRUMPower for other connector options. 5. TMP150-12, -15, -19 output connectors are without lock. TMP150-24, -27, -48 output connectors are with lock. PIN CHART PIN Product No. TMP150-12 TMP150-19 TMP150-27 TMP150-15 TMP150-24 TMP150-48 1 2 3 4 Shell Return Output +V Return Output +V AC Ground Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com