PMP120 - PROTEK POWER

96-120 WATT MEDICAL & ITE POWER SUPPLIES
DESCRIPTION
PMP120 SERIES
(LVD)
The PMP120 series of AC/DC switching power supplies are for 96-120
RoHS
watts of continuous output power. They are enclosed in a 94V-1 rated
polyphenylene-oxide case with an IEC320/C14 or IEC320/C18 inlet
to mate with interchangeable cord for world-wide use. All models meet
/
EN55011, EN55022 and FCC class B emission limits, and are
designed for medical and ITE applications, not for life-supporting
equipment.
FEATURES
z
z
z
z
z
z
z
z
z
Low safety ground leakage current
Both Class I and Class II models are certified
to medical and ITE safety standards.
W i d e i n p u t r a n g e 9 0 t o 2 6 4 VA C
Optional output connectors
100% burn-in
Overvoltage protection
Overcurrent protection
C o m p l i a n t w i t h C E C a n d E n e r g y St a r E f f i c i e n c y
level V requirements (except PMP120-12, -13,
13-1, -13-2 and -13-3 to level IV)
* No load power consumption less than 0.5 W
* Average active efficiency ≧ 87%
Compliant with RoHS requirements
SAFETY STANDARD APPROVALS
UL 60601-1, CSA C22.2 No. 601.1
File No. E178020
TÜV EN 60601-1
UL 60950-1, CSA C22.2 No. 60950-1
File No. E137410
TÜV EN 60950-1
GENERAL SPECIFICATIONS
Switching frequency:
50-110 KHz
INPUT SPECIFICATIONS
Power factor:
0.98 Typical at 115 VAC
Input voltage:
90-264 VAC
Efficiency:
85% min. at full load
Input frequency:
47-63 Hz
Hold-up time:
15 ms minimum at 110 VAC
Input current:
1.60 A (rms) for 115 VAC
Line regulation:
±0.5% maximum at full load
0.80 A (rms) for 230 VAC
Inrush current:
60 A @ 115 VAC or 120 A @ 230 VAC, at
Withstand voltage:
4000 VAC from input to output,
Earth leakage current:
180 μA max. @ 264 VAC, 63 Hz
Touch current:
100 μA max. @ 264 VAC, 63 Hz
25℃ cold start
1500 VAC from input to ground,
500 VAC from output to ground
MTBF:
OUTPUT SPECIFICATIONS
150,000 hours at full load at 25℃ambient ,
calculated per MIL-HDBK-217F
Output voltage /current:
See rating chart.
EMC Performance (IEC60601-1-2)
Maximum output power:
Ripple and noise:
Overvoltage protection:
See rating chart.
1% peak to peak maximum
Provided and set at 112-140% of its
nominal output voltage
Protected to short circuit conditions
EN55011 /EN55022:
±0.04% /℃ maximum
Maximum excursion of 4% or better on
all models, recovering to 1% of final
value within 500 us after a 25% step
load change
Overcurrent protection:
Temperature coefficient:
Transient response:
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
0℃ to +60℃
-40℃ to +85℃
5% to 95% non-condensing
Derate from 100% at +40℃ linearly to
50% at +60℃
Class B conducted, class B radiated
FCC:
Class B conducted, class B radiated
VCCI:
Class B conducted, class B radiated
EN61000-3-2:
Harmonic distortion, class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8 KV air and ±6 KV contact
EN61000-4-3:
Radiated immunity, 3 V/m
EN61000-4-4:
Fast transient/burst, ±2 KV
EN61000-4-5:
Surge, ±1 KV diff., ±2 KV com.
EN61000-4-6:
Conducted immunity, 3 Vrms
EN61000-4-8:
Magnetic field immunity, 3 A/m
EN61000-4-11:
Voltage dip immunity, 30% reduction for 500
ms,
60% reduction for 100 ms and >95%
reduction for 10 ms
51
UNIVERSAL INPUT
PMP120 MEDICAL & ITE SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Model
Class I
PMP120-12
PMP120-13
PMP120-13-1
PMP120-13-2
PMP120-13-3
PMP120-14
PMP120-16
PMP120-17
PMP120-18
(1)
Output
Class II
PMP120F-12
PMP120F-13
PMP120F-13-1
PMP120F-13-2
PMP120F-13-3
PMP120F-14
PMP120F-16
PMP120F-17
PMP120F-18
V1
12 V
15 V
18 V
19 V
20 V
24 V
30 V
36 V
48 V
Min. Current Max. Current
0A
8.00 A
0A
7.00 A
0A
6.67 A
0A
6.32 A
0A
6.00 A
0A
5.00 A
0A
4.00 A
0A
3.34 A
0A
2.50 A
Ripple &
(2)
Noise
120 mV
150 mV
180 mV
190 mV
200 mV
240 mV
300 mV
360 mV
480 mV
Tol.
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Max. Power
96 W
105 W
120 W
120 W
120 W
120 W
120 W
120 W
120 W
Average Active
Efficiency (typical)
@ 115 / 230 Vac
86 / 86 %
86 / 86 %
87 / 86 %
87 / 86 %
87 / 86 %
88 / 88 %
89 / 88 %
89 / 88 %
88 / 88 %
NOTES:
1.
Class I models are equipped with IEC320/C14 inlet, and class II models with IEC320/C18 inlet.
2.
Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage
and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output.
MECHANICAL SPECIFICATIONS
OUTPUT POWER DERATING CURVE
NOTES:
1.
Dimensions shown in inches [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Weight: 780 grams (1.716 lbs.) approx.
4.
Output connector is 4 pin plug without lock, mating with Kycon P/N KPJX-4S-S socket or
equivalent.
5.
Refer to Section titled “OPTIONAL OUTPUT CONNECTORS”. Add the suffix
assigned for a selected connector to a wanted model number, e.g.
PMP120-14-B1, for ordering.
PIN CHART
PIN
MODEL
PMP120-12
PMP120F-12
PMP120-13
PMP120F-13
PMP120-13-1
PMP120F-13-1
PMP120-13-2
PMP120F-13-2
PMP120-13-3
PMP120-14
PMP120-16
PMP120-17
PMP120-18
PMP120F-13-3
PMP120F-14
PMP120F-16
PMP120F-17
PMP120F-18
1
2
3
4
V1 Return
+V1
V1 Return
+V1
52