TM TMP431 TMP432 P432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com ±1°C TEMPERATURE SENSOR with Series-R, η-Factor, and Automatic Beta Compensation Check for Samples: TMP431, TMP432 FEATURES DESCRIPTION • • • • • • • The TMP431 and TMP432 are remote temperature sensor monitors with a built-in local temperature sensor. The remote temperature sensor diode-connected transistors are typically low-cost, NPN- or PNP-type transistors or diodes that are an integral part of microcontrollers, microprocessors, or FPGAs. 1 234 • • • ±1°C REMOTE DIODE SENSOR ±1°C LOCAL TEMPERATURE SENSOR AUTOMATIC BETA COMPENSATION η-FACTOR CORRECTION PROGRAMMABLE THRESHOLD LIMITS TWO-WIRE/ SMBus™ SERIAL INTERFACE MINIMUM AND MAXIMUM TEMPERATURE MONITORS MULTIPLE INTERFACE ADDRESSES ALERT/THERM2 PIN CONFIGURATION DIODE FAULT DETECTION APPLICATIONS • • • • • • • • LCD/DLP®/LCOS PROJECTORS SERVERS INDUSTRIAL CONTROLLERS CENTRAL OFFICE TELECOM EQUIPMENT DESKTOP AND NOTEBOOK COMPUTERS STORAGE AREA NETWORKS (SAN) INDUSTRIAL AND MEDICAL EQUIPMENT PROCESSOR/FPGA TEMPERATURE MONITORING Remote accuracy is ±1°C for multiple IC manufacturers, with no calibration needed. The Two-Wire serial interface accepts SMBus write byte, read byte, send byte, and receive byte commands to program the alarm thresholds and to read temperature data. DLP® The TMP431/32 include beta compensation (correction), series resistance cancellation, programmable non-ideality factor, programmable resolution, programmable threshold limits, minimum and maximum temperature monitors, wide remote temperature measurement range (up to +150°C), and diode fault detection and temperature alert function. The TMP431 is available in an MSOP-8 package and the TMP432 is available in an MSOP-10 package. +5V +5V TMP431 TMP432 1 1 V+ SCL 2 3 V+ 8 2 SCL DXN1 SDA 10 DXP SDA 3 7 DXN 9 SMBus Controller SMBus Controller 4 4 DXP2 THERM 5 DXP1 5 GND ALERT/ 8 THERM2 DXN2 7 THERM GND ALERT/THERM2 6 One Channel Local One Channel Remote 6 One Channel Local Two Channels Remote 1 2 3 4 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. DLP is a registered trademark of Texas Instruments. SMBus is a trademark of Intel Corporation. All other trademarks are the property of their respective owners. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. © 2009–2011, Texas Instruments Incorporated TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. PACKAGE INFORMATION (1) (1) TWO-WIRE ADDRESS THERM HIGH LIMIT PACKAGELEAD PACKAGE DESIGNATOR PACKAGE MARKING Remote Junction Temperature Sensor 100 1100 +85°C MSOP-8 DGK DRTI TMP431B Remote Junction Temperature Sensor 100 1101 +85°C MSOP-8 DGK DRUI TMP431C Remote Junction Temperature Sensor 100 1100 +105°C MSOP-8 DGK DUEC TMP431D Remote Junction Temperature Sensor 100 1101 +105°C MSOP-8 DGK DUFC TMP432A Remote Junction Temperature Sensor 100 1100 +85°C MSOP-10 DGS DSCI TMP432B Remote Junction Temperature Sensor 100 1101 +85°C MSOP-10 DGS DSDI PRODUCT DESCRIPTION TMP431A For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the device product folder at www.ti.com. ABSOLUTE MAXIMUM RATINGS (1) Over operating free-air temperature range, unless otherwise noted. Power Supply, VS TMP431, TMP432 UNIT +7.0 V TMP431 Input Voltage Pins 2, 3, and 6 only –0.5 to VS + 0.5 V Pins 4, 7, and 8 only –0.5 to 7 V TMP432 Input Voltage Pins 2, 3, 4, 5, and 8 only –0.5 to VS + 0.5 V –0.5 to 7 V 10 mA Operating Temperature Range –55 to +127 °C Storage Temperature Range –60 to +130 °C +150 °C Human Body Model (HBM) 4000 V Charged Device Model (CDM) 1000 V Machine Model (MM) 200 V Pins 7, 9, and 10 only Input Current Junction Temperature (TJ max) ESD Rating (1) 2 Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com ELECTRICAL CHARACTERISTICS At TA = –40°C to +125°C and VS = 2.7V to 5.5V, unless otherwise noted. TMP431 TMP432 PARAMETER CONDITIONS MIN TYP MAX UNIT TEMPERATURE ERROR Local Temperature Sensor Remote Temperature Sensor (1) TELOCAL TEREMOTE vs Supply (Local/Remote) TA = –40°C to +125°C ±1.25 ±2.5 °C TA = +0°C to +100°C, VS = 3.3V ±0.25 ±1 °C TA = 0°C to +100°C, TDIODE = –40°C to +150°C, VS = 3.3V ±0.25 ±1 °C TA = –40°C to +100°C, TDIODE = –40°C to +150°C, VS = 3.3V ±0.5 ±1.5 °C TA = –40°C to +125°C, TDIODE = –40°C to +150°C ±3 ±5 °C VS = 2.7V to 5.5V ±0.2 ±0.5 °C/V 12 15 17 ms RC = 1 97 126 137 ms RC = 0 36 47 52 ms RC = 1 72 93 100 ms RC = 0 33 44 47 ms TEMPERATURE MEASUREMENT Conversion Time (per channel) Local Channel Remote Channel MBeta Correction Enabled (2) MBeta Correction Disabled (3) Resolution Local Channel 12 Bits Remote Channel 12 Bits Remote Sensor Source Currents 120 μA Medium High 60 μA Medium Low 12 μA Low 6 μA High Remote Transistor Ideality Factor Series Resistance (beta correction) (4) η 1.000 (2) TMP431/32 optimized ideality factor 1.008 (3) β 0.1 Logic Input High Voltage (SCL, SDA) VIH 2.1 Logic Input Low Voltage (SCL, SDA) VIL Beta Correction Range 27 SMBus INTERFACE Hysteresis 500 SMBus Output Low Sink Current SDA Output Low Voltage V 0.8 6 VOL IOUT = 6mA 0 ≤ VIN ≤ 6V Logic Input Current mA 0.15 –1 SMBus Input Capacitance (SCL, SDA) 0.4 V +1 μA 3 SMBus Clock Frequency SMBus Timeout 25 V mV 32 SCL Falling Edge to SDA Valid Time pF 3.4 MHz 35 ms 1 μs DIGITAL OUTPUTS Output Low Voltage VOL IOUT = 6mA 0.15 0.4 V High-Level Output Leakage Current IOH VOUT = VS 0.1 1 μA ALERT/THERM2 Output Low Sink Current THERM Output Low Sink Current (1) (2) (3) (4) ALERT/THERM2 Forced to 0.4V 6 mA THERM2 Forced to 0.4V 6 mA Tested with less than 5Ω effective series resistance and 100pF differential input capacitance. TA is the ambient temperature of the TMP431/32. TDIODE is the temperature at the remote diode sensor. Beta correction configuration set to '1000' and sensor is GND collector-connected (PNP collector to ground). Beta correction configuration set to '0111' or sensor is diode-connected (base shorted to collector). If beta correction is disabled ('0111'), then up to 1kΩ of series line resistance is cancelled; if beta correction is enabled ('1xxx'), up to 300Ω is cancelled. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 3 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com ELECTRICAL CHARACTERISTICS (continued) At TA = –40°C to +125°C and VS = 2.7V to 5.5V, unless otherwise noted. TMP431 TMP432 PARAMETER CONDITIONS MIN TYP MAX UNIT POWER SUPPLY Specified Voltage Range VS Quiescent Current IQ Undervoltage Lockout Power-On Reset Threshold 2.7 5.5 V 45 μA 0.7 1 mA 3 10 μA 0.0625 Conversions per Second, VS = 3.3V 35 Eight Conversions per Second, VS = 3.3V (5) Serial Bus Inactive, Shutdown Mode Serial Bus Active, fS = 400kHz, Shutdown Mode 90 Serial Bus Active, fS = 3.4MHz, Shutdown Mode 350 UVLO 2.3 POR μA μA 2.4 2.6 V 1.6 2.3 V TEMPERATURE RANGE Specified Range –40 +125 °C Storage Range –60 +130 °C Thermal Resistance (5) 4 MSOP-8 θJA 215 °C/W MSOP-10 θJA 165 °C/W Beta correction disabled. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com PIN CONFIGURATIONS DGK PACKAGE MSOP-8 (TOP VIEW) V+ 1 DXP 2 8 SCL 7 SDA TMP431 DXN 3 6 ALERT/THERM2 THERM 4 5 GND TMP431 PIN ASSIGNMENTS TMP431 NO. NAME 1 V+ DESCRIPTION 2 DXP Positive connection to remote temperature sensor 3 DXN Negative connection to remote temperature sensor 4 THERM 5 GND 6 ALERT/THERM2 7 SDA Serial data line for SMBus, open-drain; requires pull-up resistor to V+ 8 SCL Serial clock line for SMBus, open-drain; requires pull-up resistor to V+ Positive supply (2.7V to 5.5V) Thermal flag, active low, open-drain; requires pull-up resistor to V+ Ground Alert (reconfigurable as second thermal flag), active low, open-drain; requires pull-up resistor to V+ DGS PACKAGE MSOP-10 (TOP VIEW) V+ 10 SCL 1 DXP1 2 DXN1 3 TMP432 9 SDA 8 ALERT/THERM2 DXP2 4 7 THERM DXN2 5 6 GND TMP432 PIN ASSIGNMENTS TMP432 NO. NAME 1 V+ DESCRIPTION 2 DXP1 Channel 1 positive connection to remote temperature sensor 3 DXN1 Channel 1 negative connection to remote temperature sensor 4 DXP2 Channel 2 positive connection to remote temperature sensor 5 DXN2 Channel 2 negative connection to remote temperature sensor 6 GND Ground 7 THERM 8 ALERT/THERM2 9 SDA Serial data line for SMBus, open-drain; requires pull-up resistor to V+ 10 SCL Serial clock line for SMBus, open-drain; requires pull-up resistor to V+ Positive supply (2.7V to 5.5V) Thermal flag, active low, open-drain; requires pull-up resistor to V+ Alert (reconfigurable as second thermal flag), active low, open-drain; requires pull-up resistor to V+ Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 5 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com TYPICAL CHARACTERISTICS At TA = +25°C and VS = 3.3V, unless otherwise noted. REMOTE TEMPERATURE ERROR vs TEMPERATURE LOCAL TEMPERATURE ERROR vs TEMPERATURE 3 Local Temperature Error (°C) Remote Temperature Error (°C) 3 2 1 0 -1 -2 Beta Compensation Disabled. GND Collector-Connected Transistor with n-Factor = 1.008. -3 2 1 0 -1 -2 -3 -50 75 0 25 50 Ambient Temperature, TA (°C) -25 100 125 -50 -25 75 0 25 50 Ambient Temperature, TA (°C) Figure 1. Figure 2. REMOTE TEMPERATURE ERROR vs LEAKAGE RESISTANCE QUIESCENT CURRENT vs CONVERSION RATE 150 700 100 600 100 125 RGND (Low Beta) 50 500 RGND IQ (mA) Remote Temperature Error (°C) VS = 3.3V 0 -50 -100 0 0.0625 0.125 -150 10 TMP431 100 RVs (Low Beta) 5 TMP432 300 200 RVs 0 400 15 20 25 30 1 4 2 Figure 4. SHUTDOWN QUIESCENT CURRENT vs SCL CLOCK FREQUENCY SHUTDOWN QUIESCENT CURRENT vs SUPPLY VOLTAGE 500 4.0 450 3.5 8 3.0 350 VS = 5.5V 300 2.5 IQ (mA) IQ (mA) 0.5 Figure 3. 400 250 200 2.0 1.5 150 1.0 100 50 0.5 VS = 3.3V 0 0 1k 10k 100k 1M 10M 2.5 3.0 3.5 4.0 4.5 5.0 5.5 VS (V) SCL Clock Frequency (Hz) Figure 5. 6 0.25 Conversion Rate (conversions/s) Leakage Resistance (MW) Figure 6. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com TYPICAL CHARACTERISTICS (continued) At TA = +25°C and VS = 3.3V, unless otherwise noted. REMOTE TEMPERATURE ERROR vs SERIES RESISTANCE (Low-Beta Transistor) REMOTE TEMPERATURE ERROR vs SERIES RESISTANCE 2.5 GND Collector-Connected Transistor, 2N3906 (PNP) (1)(2) 2 1 0 Diode-Connected Transistor, 2N3906 (PNP) (2) -1 NOTES (1): Temperature offset is the result of h-factor being automatically set to 1.000. Approximate h-factor of 2N3906 is 1.008. (2) See Figure 11 for schematic configuration. -2 Remote Temperature Error (°C) Remote Temperature Error (°C) 3 2.0 1.5 1.0 0.5 0 -0.5 -1.0 -1.5 -2.0 -2.5 -3 0 100 200 300 400 500 600 700 800 900 0 1k 100 200 REMOTE TEMPERATURE ERROR vs DIFFERENTIAL CAPACITANCE AT +25°C, VCC = 3.3V, RS = 0Ω REMOTE TEMPERATURE ERROR vs DIFFERENTIAL CAPACITANCE with 45nm CPU AT +25°C, VCC = 3.3V, RS = 0Ω, Beta = 011 (AUTO) 3 2 Low-Beta Transistor (Disabled) GND CollectorConnected Transistor (Disabled) 0 -1 Diode-Connected Transistor (Auto, Disabled) -2 500 Figure 8. GND Collector-Connected Transistor (Auto) 1 400 Figure 7. Remote Temperature Error (°C) Remote Temperature Error (°C) 3 300 RS (W) RS (W) 2 1 0 Low-Beta Transistor (Auto) -1 -2 NOTE: See Figure 12 for schematic configuration. -3 -3 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Capacitance (nF) Capacitance (nF) Figure 9. Figure 10. 1.6 1.8 2.0 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 2.2 7 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com PARAMETRIC MEASUREMENT INFORMATION TYPICAL CONNECTIONS SERIES RESISTANCE CONFIGURATION (a) GND Collector-Connected Transistor RS (1) DXP DXN RS (1) (b) Diode-Connected Transistor (1) RS DXP DXN RS (1) (1) RS should be less than 1kΩ; see Filtering section. Figure 11. DIFFERENTIAL CAPACITANCE CONFIGURATION (a) GND Collector-Connected Transistor DXP CDIFF (1) DXN (b) Diode-Connected Transistor DXP CDIFF (1) DXN (1) CDIFF should be less than 2200pF; see Filtering section. Figure 12. 8 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com APPLICATION INFORMATION The TMP431 (two-channel) and TMP432 (three-channel) are digital temperature sensors that combine a local die temperature measurement channel and a remote junction temperature measurement channel in a single MSOP-8 (TMP431) or MSOP-10 (TMP432) package. They are Two-Wireand SMBus interface-compatible and are specified over a temperature range of –40°C to +125°C. The TMP431/32 contain multiple registers for holding configuration information, temperature measurement results, temperature comparator maximum/minimum limits, and status information. User-programmed high and low temperature limits stored in the TMP431/32 can be used to trigger an over/under temperature alarm (ALERT) on local and remote temperatures. Additional thermal limits can be programmed into the TMP431/32 and used to trigger another flag (THERM) that can be used to initiate a system response to rising temperatures. For proper remote temperature sensing operation, the TMP431 requires only a transistor connected between DXP and DXN; the TMP432 requires transistors conncected between DXP1 and DXN1, and between DXP2 and DXN2. The SCL and SDA interface pins require pull-up resistors as part of the communication bus, while ALERT and THERM are open-drain outputs that also need pull-up resistors. ALERT and THERM may be shared with other devices if desired for a wired-OR implementation. A 0.1μF power-supply bypass capacitor is recommended for good local bypassing. See Figure 13 for a typical configuration of the TMP431; see Figure 14 for a typical configuration of the TMP432. Beta Compensation controlling the emitter current provided acceptable temperature measurement results. At 90nm process geometry and below, however, the beta factor continues to decrease and the premise that it is independent of collector current becomes less certain. To manage this increasing temperature measurement error, the TMP431/32 control the collector current instead of the emitter current. The TMP431/32 automatically detect and choose the correct range depending on the beta factor of the external transistor. This auto-ranging is performed at the beginning of each temperature conversion in order to correct for any changes in the beta factor as a result of temperature variation. The device can operate a PNP transistor with a beta factor as low as 0.1. See the Beta Compensation Configuration Register section for further information. Series Resistance Cancellation Series resistance in an application circuit that typically results from printed circuit board (PCB) trace resistance and remote line length is automatically cancelled by the TMP431/32, preventing what would otherwise result in a temperature offset. A total of up to 1kΩ of series line resistance is cancelled by the TMP431/32 if beta correction is disabled and up to 300Ω of series line resistance is cancelled if beta correction is enabled, eliminating the need for additional characterization and temperature offset correction. See the two Remote Temperature Error vs Series Resistance typical characteristic curves (Figure 7 and Figure 8) for details on the effects of series resistance on sensed remote temperature error. Differential Input Capacitance Previous generations of remote junction temperature sensors were operated by controlling the emitter current of the sensing transistor. However, examination of the physics of a transistor shows that VBE is actually a function of the collector current. If beta is independent of the collector current, then VBE may be calculated from the emitter current. In earlier generations of processors that contained PNP transistors connected to these temperature sensors, The TMP431/32 can tolerate differential input capacitance of up to 2200pF with minimal change in temperature error. The effect of capacitance on sensed remote temperature error is illustrated in Figure 9 and Figure 10, Remote Temperature Error vs Differential Capacitance. See the Filtering section for suggested component values where filtering unwanted coupled signals is needed. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 9 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com +5V 0.1mF (1) GND collector-connected transistor configuration : Series Resistance RS V+ (2) SCL 2 DXP CDIFF SDA 3 10kW (typ) 10kW (typ) 10kW (typ) 8 TMP431 (3) (2) RS 10kW (typ) 1 7 SMBus Controller DXN ALERT/THERM2 THERM 6 4 Fan Controller GND (1) 5 Diode-connected configuration : (2) RS (3) (2) NOTES: (1) Diode-connected configuration provides better settling time. GND collector-connected transistor configuration provides better series resistance cancellation. (2) RS (optional) should be < 1kW in most applications. Selection of RS depends on specific application; see Filtering section. (3) CDIFF should be < 2200pF. Selection of CDIFF depends on specific application; see Filtering section and Figure 9, Remote Temperature Error vs Differential Capacitance. CDIFF RS Figure 13. TMP431 Basic Connections +5V (1) GND collector-connected transistor configuration : 0.1mF Series Resistance RS RS (2) V+ 2 (3) CDIFF (2) RS RS 10kW (typ) 1 SCL DXP1 TMP432 3 SDA DXN1 (2) ALERT/THERM2 4 10kW (typ) 10kW (typ) 10kW (typ) 10 9 SMBus Controller 8 DXP2 (3) (2) CDIFF 5 THERM DXN2 7 Fan Controller GND 6 (1) Diode-connected configuration : RS (2) (2) RS (3) CDIFF NOTES: (1) Diode-connected configuration provides better settling time. GND collector-connected transistor configuration provides better series resistance cancellation. (2) RS (optional) should be < 1kW in most applications. Selection of RS depends on specific application; see Filtering section. (3) CDIFF should be < 2200pF. Selection of CDIFF depends on specific application; see Filtering section and Figure 9, Remote Temperature Error vs Differential Capacitance. Figure 14. TMP432 Basic Connections 10 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Temperature Measurement Data Temperature measurement data are taken over a default range of 0°C to +127°C for both local and remote locations. However, measurements from –55°C to +150°C can be made both locally and remotely by reconfiguring the TMP431/32 for the extended temperature range, as described in this section. Temperature data resulting from conversions within the default measurement range are represented in binary form, as shown in Table 1, Standard Binary column. Note that any temperature below 0°C results in a data value of zero (00h). Likewise, temperatures above +127°C result in a value of 127 (7Fh). The device can be set to measure over an extended temperature range by changing bit 2 of Configuration Register 1 from low to high. The change in measurement range and data format from standard binary to extended binary occurs at the next temperature conversion. For data captured in the extended temperature range configuration, an offset of 64 (40h) is added to the standard binary value, as shown in Table 1, Extended Binary column. This configuration allows measurement of temperatures as low as –64°C, and as high as +191°C; however, most temperature-sensing diodes only measure with the range of –55°C to +150°C. Additionally, the TMP431/32 are rated only for ambient local temperatures ranging from –40°C to +125°C. Parameters in the Absolute Maximum Ratings table must be observed. Both local and remote temperature data use two bytes for data storage. The high byte stores the temperature with 1°C resolution. The second or low byte stores the decimal fraction value of the temperature and allows a higher measurement resolution, as shown in Table 2. The measurement resolution for both the local and remote channels is 0.0625°C, and cannot be adjusted. Table 1. Temperature Data Format (Local and Remote Temperature High Bytes) LOCAL/REMOTE TEMPERATURE REGISTER HIGH BYTE VALUE (+1°C RESOLUTION) STANDARD BINARY (1) (1) (2) EXTENDED BINARY (2) TEMP (°C) BINARY HEX BINARY −64 0000 0000 00 0000 0000 HEX 00 −50 0000 0000 00 0000 1110 0E −25 0000 0000 00 0010 0111 27 0 0000 0000 00 0100 0000 40 1 0000 0001 01 0100 0001 41 5 0000 0101 05 0100 0101 45 10 0000 1010 0A 0100 1010 4A 25 0001 1001 19 0101 1001 59 50 0011 0010 32 0111 0010 72 8B 75 0100 1011 4B 1000 1011 100 0110 0100 64 1010 0100 A4 125 0111 1101 7D 1011 1101 BD 127 0111 1111 7F 1011 1111 BF 150 0111 1111 7F 1101 0110 D6 175 0111 1111 7F 1110 1111 EF 191 0111 1111 7F 1111 1111 FF Resolution is 1°C/count. Negative numbers are represented in twos complement format. Resolution is 1°C/count. All values are unsigned with a –64°C offset. space space Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 11 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Table 2. Decimal Fraction Temperature Data Format (Local and Remote Temperature Low Bytes) TEMP (°C) (1) TEMPERATURE REGISTER LOW BYTE VALUE (0.0625°C RESOLUTION) (1) STANDARD AND EXTENDED BINARY HEX 0 0000 0000 00 0.0625 0001 0000 10 0.1250 0010 0000 20 0.1875 0011 0000 30 0.2500 0100 0000 40 0.3125 0101 0000 50 0.3750 0110 0000 60 0.4375 0111 0000 70 0.5000 1000 0000 80 0.5625 1001 0000 90 0.6250 1010 0000 A0 0.6875 1011 0000 B0 0.7500 1100 0000 C0 0.8125 1101 0000 D0 0.8750 1110 0000 E0 0.9375 1111 0000 F0 Resolution is 0.0625°C/count. All possible values are shown. REGISTER INFORMATION The TMP431/32 contain multiple registers for holding configuration information, temperature measurement results, temperature comparator maximum/minimum, limits, and status information. These registers are described in Figure 15 and in Table 3 for the TMP431, and in Table 4 for the TMP432. Pointer Register Local and Remote Temperature Registers Local and Remote Limit Registers THERM Hysteresis Register SDA Status Register Configuration Register Beta Correction Register I/O Control Interface Conversion Rate Register SCL Consecutive Alert Register Identification Registers Figure 15. Internal Register Structure 12 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Table 3. TMP431 Register Map POINTER ADDRESS (HEX) (1) (2) (3) (4) BIT DESCRIPTIONS READ WRITE POWER-ON RESET (HEX) D7 D6 D5 D4 D3 D2 D1 D0 00 NA (1) 00 LT11 LT10 LT9 LT8 LT7 LT6 LT5 LT4 Local Temperature (High Byte) 01 NA 00 RT11 RT10 RT9 RT8 RT7 RT6 RT5 RT4 Remote Temperature (High Byte) 02 NA 80 BUSY LHIGH LLOW RHIGH RLOW OPEN RTHRM LTHRM Status Register 03 09 00 MASK SD AL/TH 0 0 RANGE 0 0 Configuration Register 1 04 0A 07 0 0 0 0 R3 R2 R1 R0 Conversion Rate Register 05 0B 55 LTH11 LTH10 LTH9 LTH8 LTH7 LTH6 LTH5 LTH4 Local Temperature High Limit (High Byte) 06 0C 00 LTL11 LTL10 LTL9 LTL8 LTL7 LTL6 LTL5 LTL4 Local Temperature Low Limit (High Byte) 07 0D 55 RTH11 RTH10 RTH9 RTH8 RTH7 RTH6 RTH5 RTH4 Remote Temperature High Limit (High Byte) 08 0E 00 RTL11 RTL10 RTL9 RTL8 RTL7 RTL6 RTL5 RTL4 Remote Temperature Low Limit (High Byte) NA 0F XX X (2) X X X X X X X One-Shot Start 10 NA 00 RT3 RT2 RT1 RT0 0 0 0 0 Remote Temperature (Low Byte) 13 13 00 RTH3 RTH2 RTH1 RTH0 0 0 0 0 Remote Temperature High Limit (Low Byte) 14 14 00 RTL3 RTL2 RTL1 RTL0 0 0 0 0 Remote Temperature Low Limit (Low Byte) 15 NA 00 LT3 LT2 LT1 LT0 0 0 0 0 Local Temperature (Low Byte) 16 16 00 LTH3 LTH2 LTH1 LTH0 0 0 0 0 Local Temperature High Limit (Low Byte) 17 17 00 LTL3 LTL2 LTL1 LTL0 0 0 0 0 Local Temperature Low Limit (Low Byte) 18 18 00 NC7 NC6 NC5 NC4 NC3 NC2 NC1 NC0 N-factor Correction RTHL7 RTHL6 RTHL5 RTHL4 RTHL3 RTHL2 RTHL1 RTHL0 Remote THERM Limit 0 0 0 REN LEN RC 0 0 Configuration Register 2 55 (3) REGISTER DESCRIPTIONS 19 19 1A 1A 1F 1F 00 0 0 0 0 0 0 RIMASK LMASK Channel Mask 20 20 55 (3) LTHL7 LTHL6 LTHL5 LTHL4 LTHL3 LTHL2 LTHL1 LTHL0 Local THERM Limit 21 21 0A TH7 TH6 TH5 TH4 TH3 TH2 TH1 TH0 THERM Hysteresis 22 22 70 0 CTH2 CTH1 CTH0 CALT2 CALT1 CALT0 0 Consecutive Alert Register 25 25 08 0 0 0 0 BC3 BC2 BC1 BC0 Beta Range Register NA FC 00 X (4) X X X X X X X Software Reset FD NA 31 0 0 1 1 0 0 0 1 TMP431 Device ID FE NA 55 0 1 0 1 0 1 0 1 Manufacturer ID 1C NA = Not applicable; register is write- or read-only. X = Indeterminate state. TMP431C and TMP431D versions have a power-on reset value of 69h. X = Undefined. Writing any value to this register initiates a software reset; see the Software Reset section. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 13 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Table 4. TMP432 Register Map POINTER ADDRESS (1) (2) 14 BIT DESCRIPTIONS READ WRITE POWER-ON RESET (HEX) D7 D6 D5 D4 D3 D2 D1 D0 REGISTER DESCRIPTIONS 00 NA (1) 00 LT11 LT10 LT9 LT8 LT7 LT6 LT5 LT4 Local Temperature (High Byte) 01 NA 00 RT11 RT10 RT9 RT8 RT7 RT6 RT5 RT4 Remote Temperature1 (High Byte) 02 NA 80 BUSY 0 0 HIGH LOW OPEN THERM 0 Status Register 03 09 00 MASK SD AL/TH 0 0 RANGE 0 0 Configuration Register1 04 0A 07 0 0 0 0 R3 R2 R1 R0 Conversion Rate Register 05 0B 55 LTH11 LTH10 LTH9 LTH8 LTH7 LTH6 LTH5 LTH4 Local Temperature High Limit (High Byte) 06 0C 00 LTL11 LTL10 LTL9 LTL8 LTL7 LTL6 LTL5 LTL4 Local Temperature Low Limit (High Byte) 07 0D 55 RTH11 RTH10 RTH9 RTH8 RTH7 RTH6 RTH5 RTH4 Remote Temperature1 High Limit (High Byte) 08 0E 00 RTL11 RTL10 RTL9 RTL8 RTL7 RTL6 RTL5 RTL4 Remote Temperature1 Low Limit (High Byte) NA 0F XX X (2) X X X X X X X One-Shot Start 10 NA 00 RT3 RT2 RT1 RT0 0 0 0 0 Remote Temperature1 (Low Byte) 13 13 00 RTH3 RTH2 RTH1 RTH0 0 0 0 0 Remote Temperature1 High Limit (Low Byte) 14 14 00 RTL3 RTL2 RTL1 RTL0 0 0 0 0 Remote Temperature1 Low Limit (Low Byte) 15 15 55 RTH11 RTH10 RTH9 RTH8 RTH7 RTH6 RTH5 RTH4 Remote Temperature2 High Limit (High Byte) 16 16 00 RTL11 RTL10 RTL9 RTL8 RTL7 RTL6 RTL5 RTL4 Remote Temperature2 Low Limit (High Byte) 17 17 00 RTH3 RTH2 RTH1 RTH0 0 0 0 0 Remote Temperature2 High Limit (Low Byte) 18 18 00 RTL3 RTL2 RTL1 RTL0 0 0 0 0 Remote Temperature2 Low Limit (Low Byte) 19 19 55 RTHL7 RTHL6 RTHL5 RTHL4 RTHL3 RTHL2 RTHL1 RTHL0 Remote Therm Limit 1A 1A 55 RTHL7 RTHL6 RTHL5 RTHL4 RTHL3 RTHL2 RTHL1 RTHL0 Remote2 Therm Limit 1B 1B 00 0 0 0 0 0 R2FAULT R1FAULT 0 Fault Status 1F 1F 00 0 0 0 0 0 R2MASK R1MASK LMASK Channel Mask 20 20 55 LTHL7 LTHL6 LTHL5 LTHL4 LTHL3 LTHL2 LTHL1 LTHL0 Local Therm Limit 21 21 0A TH7 TH6 TH5 TH4 TH3 TH2 TH1 TH0 Therm Limit Hysteresis 22 22 70 0 CTH2 CTH1 CTH0 CALT2 CALT1 CALT0 0 Consecutive Alert Register 23 NA 00 RT11 RT10 RT9 RT8 RT7 RT6 RT5 RT4 Remote Temperature2 (High Byte) 24 NA 00 RT3 RT2 RT1 RT0 0 0 0 0 Remote Temperature2 (Low Byte) 25 25 08 0 0 0 0 BC3 BC2 BC1 BC0 Ch. 1 Beta Range Selection 26 26 08 0 0 0 0 BC3 BC2 BC1 BC0 Ch. 2 Beta Range Selection 27 27 00 NC7 NC6 NC5 NC4 NC3 NC2 NC1 NC0 N-factor Correction Remote1 NA = Not applicable; register is write- or read-only. Indeterminate state. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Table 4. TMP432 Register Map (continued) POINTER ADDRESS (3) BIT DESCRIPTIONS READ WRITE POWER-ON RESET (HEX) D7 D6 D5 D4 D3 D2 D1 D0 REGISTER DESCRIPTIONS 28 28 00 NC7 NC6 NC5 NC4 NC3 NC2 NC1 NC0 N-factor Correction Remote2 29 NA 00 T3 T2 T1 T0 0 0 0 0 Local Temperature (Low Byte) 35 35 00 0 0 0 0 0 R2HIGH R1HIGH LHIGH High Limit Status 36 36 00 0 0 0 0 0 R2LOW R1LOW LLOW Low Limit Status 37 37 00 0 0 0 0 0 R2THERM R1THERM LTHERM Therm Status 3D 3D 00 LTH3 LTH2 LTH1 LTH0 0 0 0 0 Local Temperature High Limit (Low Byte) 3E 3E 00 LTL3 LTL2 LTL1 LTL0 0 0 0 0 Local Temperature Low Limit (Low Byte) 3F 3F 3C 0 0 REN2 REN LEN RC 0 0 Configuration Register2 NA FC 00 X (3) X X X X X X X Software Reset FD NA 32 0 0 1 1 0 0 1 0 TMP432 Device ID FE NA 55 0 1 0 1 0 1 0 1 Manufacturer ID X = Undefined. Writing any value to this register initiates a software reset; see the Software Reset section. space Pointer Register Figure 15 shows the internal register structure of the TMP431/32. The 8-bit Pointer Register is used to address a given data register. The Pointer Register identifies which of the data registers should respond to a read or write command on the Two-Wire bus. This register is set with every write command. A write command must be issued to set the proper value in the Pointer Register before executing a read command. Table 3 describes the pointer address of the registers available in the TMP431. Table 4 describes the address of the registers available in the TMP432. The power-on reset (POR) value of the Pointer Register is 00h (0000 0000b). Temperature Registers The TMP431 has four 8-bit registers that hold temperature measurement results. The TMP432 has six 8-bit registers that hold temperature measurement results. Both the local channel and the remote channel have a high byte register that contains the most significant bits (MSBs) of the temperature analog-to-digital converter (ADC) result and a low byte register that contains the least significant bits (LSBs) of the temperature ADC result. The local channel high byte address for the TMP431/32 is 00h; the local channel low byte address is 15h for the TMP431 and 29h for the TMP432. The remote channel high byte is at address 01h; the remote channel low byte address is 10h. For the TMP432, the second remote channel high byte address is 23h; the second remote channel low byte is 24h. These registers are read-only and are updated by the ADC each time a temperature measurement is completed. The TMP431/32 contain circuitry to assure that a low byte register read command returns data from the same ADC conversion as the immediately preceding high byte read command. This assurance remains valid only until another register is read. For proper operation, the high byte of a temperature register should be read first. The low byte register should be read in the next read command. The low byte register may be left unread if the LSBs are not needed. Alternatively, the temperature registers may be read as a 16-bit register by using a single two-byte read command from address 00h for the local channel result, or from address 01h for the remote channel result (23h for the second remote channel result). The high byte is output first, followed by the low byte. Both bytes of this read operation are from the same ADC conversion. The power-on reset value of both temperature registers is 00h. Limit Registers The TMP431/32 have registers for setting comparator limits for both the local and remote measurement channels. These registers have read and write capability. The High and Low Limit Registers for both channels span two registers, as do the temperature registers. The local temperature high limit is set by writing the high byte to pointer address 0Bh and writing the low byte to pointer address 16h for the TMP431 and 3Dh for the TMP432, or by using a single two-byte write command (high byte first) to pointer address 0Bh. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 15 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 The local temperature high limit is obtained by reading the high byte from pointer address 05h and the low byte from pointer address 16h for the TMP4341 and 3Dh for the TMP432, or by using a two-byte read command from pointer address 05h. The power-on reset value of the local temperature high limit is 55h/00h (+85°C in standard temperature mode; +21°C in extended temperature mode). Similarly, the local temperature low limit is set by writing the high byte to pointer address 0Ch and writing the low byte to pointer address 17h for the TMP431 and 3Eh for the TMP432, or by using a single two-byte write command to pointer address 0Ch. The local temperature low limit is read by reading the high byte from pointer address 06h and the low byte from pointer address 17h and 3Eh for the TMP432, or by using a two-byte read from pointer address 06h. The power-on reset value of the local temperature low limit register is 00h/00h (0°C in standard temperature mode; –64°C in extended mode). The remote temperature high limit for the TMP431 (remote temperature1 high limit for the TMP432) is set by writing the high byte to pointer address 0Dh and writing the low byte to pointer address 13h, or by using a two-byte write command to pointer address 0Dh. The remote temperature high limit is obtained by reading the high byte from pointer address 07h and the low byte from pointer address 13h, or by using a two-byte read command from pointer address 07h. The power-on reset value of the Remote Temperature High Limit Register is 55h/00h (+85°C in standard temperature mode; +21°C in extended temperature mode). The remote temperature low limit for the TMP431 (remote temperature1 low limit for the TMP432) is set by writing the high byte to pointer address 0Eh and writing the low byte to pointer address 14h, or by using a two-byte write to pointer address 0Eh. The remote temperature low limit is read by reading the high byte from pointer address 08h and the low byte from pointer address 14h, or by using a two-byte read from pointer address 08h. The power-on reset value of the Remote Temperature Low Limit Register is 00h/00h (0°C in standard temperature mode; –64°C in extended mode). The remote temperature2 high limit for the TMP432 is set by writing the high byte to pointer address 15h and writing the low byte to pointer address 17h, or by using a two-byte write command to pointer address 15h. The remote temperature high limit is obtained by reading the high byte from pointer address 15h and the low byte from pointer address 17h, or by using a 16 www.ti.com two-byte read command from pointer address 15h. The power-on reset value of the Remote Temperature High Limit Register is 55h/00h (+85°C in standard temperature mode; +21°C in extended temperature mode). The remote temperature2 low limit for the TMP432 is set by writing the high byte to pointer address 16h and writing the low byte to pointer address 18h, or by using a two-byte write to pointer address 16h. The remote temperature low limit is read by reading the high byte from pointer address 16h and the low byte from pointer address 18h, or by using a two-byte read from pointer address 16h. The power-on reset value of the Remote Temperature Low Limit Register is 00h/00h (0°C in standard temperature mode; –64°C in extended mode). The TMP431/32 also have a THERM limit register for both the local and the remote channels. These registers are eight bits and allow for THERM limits set to 1°C resolution. The local channel THERM limit is set by writing to pointer address 20h. The remote channel THERM limit is set by writing to pointer address 19h. The remote channel THERM2 limit for the TMP432 is set by writing to pointer address 1Ah. The local channel THERM limit is obtained by reading from pointer address 20h; the remote channel THERM limit is read by reading from pointer address 19h. The remote channel THERM2 limit is read by reading from pointer address 1Ah. The power-on reset value of the THERM limit registers is 55h for the TMP431A, TMP431B, TMP432A, and TMP432B (+85°C in standard temperature mode; +21°C in extended temperature mode). The power-on reset value of the THERM limit registers is 69h for the TMP431C and TMP431D (+105°C in standard temperature mode; +41°C in extended temperature mode). The THERM limit comparators also have hysteresis. The hysteresis of both comparators is set by writing to pointer address 21h. The hysteresis value is obtained by reading from pointer address 21h. The value in the Hysteresis Register is an unsigned number (always positive). The power-on reset value of this register is 0Ah (+10°C). Whenever changing between standard and extended temperature ranges, be aware that the temperatures stored in the temperature limit registers are NOT automatically reformatted to correspond to the new temperature range format. These values must be reprogrammed in the appropriate binary or extended binary format. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Status Registers TMP431 Status Register Table 5. TMP431 Status Register Format TMP431 STATUS REGISTER (Read = 02h, Write = NA) BIT # BIT NAME POR VALUE (1) D7 D6 D5 D4 D3 D2 D1 D0 BUSY LHIGH LLOW RHIGH RLOW OPEN RTHRM LTHRM 0 (1) 0 0 0 0 0 0 0 The BUSY bit changes to ‘1’ almost immediately (<< 100μs) following power-up, as the TMP431 begins the first temperature conversion. It is high whenever the TMP431 is converting a temperature reading. space The TMP431 has a Status Register to report the state of the temperature comparators. Table 5 shows the Status Register bits. The Status Register is read-only and is read by reading from pointer address 02h. The BUSY bit reads as ‘1’ if the ADC is making a conversion. It reads as ‘0’ if the ADC is not converting. The OPEN bit reads as ‘1’ if the remote transistor was detected as open since the last read of the Status Register. The OPEN status is only detected when the ADC is attempting to convert a remote temperature. The RTHRM bit reads as ‘1’ if the remote temperature exceeds the remote THERM limit and remains greater than the remote THERM limit less the value in the shared Hysteresis Register; see Figure 21. The LTHRM bit reads as ‘1’ if the local temperature exceeds the local THERM limit and remains greater than the local THERM limit less the value in the shared Hysteresis Register; see Figure 21. The LHIGH and RHIGH bit values depend on the state of the AL/TH bit in the Configuration Register 1. If the AL/TH bit is ‘0’, the LHIGH bit reads as ‘1’ if the local high limit was exceeded since the last clearing of the Status Register. The RHIGH bit reads as ‘1’ if the remote high limit was exceeded since the last clearing of the Status Register. If the AL/TH bit is ‘1’, the remote high limit and the local high limit are used to implement a THERM2 function. LHIGH reads as ‘1’ if the local temperature exceeds the local high limit and remains greater than the local high limit less the value in the Hysteresis Register. The RHIGH bit reads as ‘1’ if the remote temperature has exceeded the remote high limit and remains greater than the remote high limit less the value in the Hysteresis Register. The LLOW and RLOW bits are not affected by the AL/TH bit. The LLOW bit reads as ‘1’ if the local low limit was exceeded since the last clearing of the Status Register. The RLOW bit reads as ‘1’ if the remote low limit was exceeded since the last clearing of the Status Register. The values of the LLOW, RLOW, and OPEN (as well as LHIGH and RHIGH when AL/TH is ‘0’) are latched and read as ‘1’ until the Status Register is read or a device reset occurs. These bits are cleared by reading the Status Register, provided that the condition causing the flag to be set no longer exists. The values of BUSY, LTHRM, and RTHRM (as well as LHIGH and RHIGH when ALERT/THERM2 is ‘1’) are not latched and are not cleared by reading the Status Register. They always indicate the current state, and are updated appropriately at the end of the corresponding ADC conversion. Clearing the Status Register bits does not clear the state of the ALERT pin; an SMBus alert response address command must be used to clear the ALERT pin. The TMP431 NORs LHIGH, LLOW, RHIGH, RLOW, and OPEN, so a status change for any of these flags from ‘0’ to ‘1’ automatically causes the ALERT pin to go low (only applies when the ALERT/THERM2 pin is configured for ALERT mode). Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 17 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Status Registers (continued) TMP432 Status Register Table 6. TMP432 Status Register Format TMP432 STATUS REGISTER (Read = 02h, Write = NA) BIT # BIT NAME POR VALUE (1) D7 D6 D5 D4 D3 D2 D1 D0 BUSY 0 0 HIGH LOW OPEN THERM 0 0 0 0 0 0 0 0 0 (1) The BUSY bit changes to ‘1’ almost immediately (<< 100μs) following power-up, as the TMP432 begins the first temperature conversion. It is high whenever the TMP432 is converting a temperature reading. space The TMP432 has a Status Register to report the state of the temperature comparators. Table 6 shows the Status Register bits. The Status Register is read-only and is read by reading from pointer address 02h. The BUSY bit reads as ‘1’ if the ADC is making a conversion. It reads as ‘0’ if the ADC is not converting. The OPEN bit reads as ‘1’ if the remote transistor was detected as open since the last read of the Status Register. The OPEN status is only detected when the ADC is attempting to convert a remote temperature. The THERM bit reads as '1' if the temperature from any channel (remote or local) has exceeded the THERM limit and remains greater than the THERM limit less the value in the shared Hysteresis Register; see Figure 21. The HIGH bit value depends on the state of the AL/TH bit in the Configuration Register 1. If the AL/TH bit is '0', the HIGH bit reads '1' if any of the temperature channels go beyond the programmed high limit since the last clearing of the Status Register. If the AL/TH bit is '1', the HIGH limit is used to implement THERM2 function. The HIGH bit reads as '1' if the temperature exceeds the high limit less the value in the Hysteresis Register. 18 The AL/TH bit does not affect the Status Register LOW bit. The LOW bit reads as '1' if any of the temperature channels go beyond the programmed low limit since the last clearing of the Status Register. The values of the LOW and OPEN bits (as well as HIGH when AL/TH is '0') are latched and read as '1' until the Status Register is read or a device reset occurs. These bits are cleared by reading the Status Register, if the condition causing the flag to be set no longer exists. The values of BUSY and THERM (as well as HIGH when AL/TH is ‘1’) are not latched and are not cleared by reading the Status Register. They always indicate the current state, and are updated appropriately at the end of the corresponding ADC conversion. Clearing the Status Register bits does not clear the state of the ALERT pin; an SMBus alert response address command must be used to clear the ALERT pin. The TMP432 NORs HIGH, LOW, and OPEN, so a status change for any of these flags from ‘0’ to ‘1’ automatically causes the ALERT pin to go low (only applies when the ALERT/THERM2 pin is configured for ALERT mode). Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Configuration Register 1 The Configuration Register 1 sets the temperature range, controls shutdown mode, and determines how the ALERT/THERM2 pin functions. The Configuration Register is set by writing to pointer address 09h and read by reading from pointer address 03h. The MASK bit (bit 7) enables or disables the ALERT pin output if ALERT/THERM = 0. If ALERT/THERM = 1 then the MASK bit has no effect. If MASK is set to ‘0’, the ALERT pin goes low when one of the temperature measurement channels exceeds its high or low limits for the chosen number of consecutive conversions. If the MASK bit is set to ‘1’, the TMP431/32 retain the ALERT pin status, but the ALERT pin does not go low. The shutdown (SD) bit (bit 6) enables or disables the temperature measurement circuitry. lf SD = 0, the TMP431/32 convert continuously at the rate set in the conversion rate register. When SD is set to '1', the TMP431/32 immediately stop converting and enter a shutdown mode. When SD is set to '0' again, the TMP431/32 resume continuous conversions. A single conversion can be started when SD = 1 by writing to the One-Shot Register. The AL/TH bit (bit 5) controls whether the ALERT pin functions in ALERT mode or THERM2 mode. If AL/TH = 0, the ALERT pin operates as an interrupt pin. In this mode, the ALERT pin goes low after the set number of consecutive out-of-limit temperature measurements occur. If AL/TH = 1, the ALERT/THERM2 pin implements a THERM function (THERM2). In this mode, THERM2 functions similar to the THERM pin except that the local high limit and remote high limit registers are used for the thresholds. THERM2 goes low when either RHIGH or LHIGH is set. The temperature range is set by configuring bit 2 of the Configuration Register 1. Setting this bit low configures the TMP431/32 for the standard measurement range (0°C to +127°C); temperature conversions will be stored in the standard binary format. Setting bit 2 high configures the TMP431/32 for the extended measurement range (–55°C to +150°C); temperature conversions are stored in the extended binary format (see Table 1). The remaining bits of the Configuration Register 1 are reserved and must always be set to ‘0’. The power-on reset value for this register is 00h. Table 7 summarizes the bits of the Configuration Register 1. Table 7. Configuration Register 1 Bit Descriptions CONFIGURATION REGISTER 1 (Read = 03h, Write = 09h, POR = 00h) BIT NAME FUNCTION POWER-ON RESET VALUE 7 MASK 0 = ALERT Enabled 1 = ALERT Masked 0 6 SD 0 = Run 1 = Shut Down 0 5 AL/TH 0 = ALERT Mode 1 = THERM Mode 0 4, 3 Reserved — 0 2 Temperature Range 0 = 0°C to +127°C 1 = −55°C to +150°C 0 1, 0 Reserved — 0 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 19 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 Configuration Register 2 Configuration Register 2 (pointer address 1Ah for the TMP431 and 3Fh for the TMP432) controls which temperature measurement channels are enabled and whether the external channels have the resistance correction feature enabled or not. The RC bit enables the resistance correction feature for the external temperature channels. If RC = '1', series resistance correction is enabled; if RC = '0', resistance correction is disabled. Resistance correction should be enabled for most applications. However, disabling the resistance correction may yield slightly improved temperature measurement noise performance, and reduce conversion time by about 50%, which could lower power consumption when conversion rates of two per second or less are selected. www.ti.com The LEN bit enables the local temperature measurement channel. If LEN = '1', the local channel is enabled; if LEN = '0', the local channel is disabled. The REN bit enables external temperature measurement channel 1 (connected to pins 2 and 3.) If REN = '1', the external channel is enabled; if REN = '0', the external channel is disabled. For the TMP432 only, the REN2 bit enables the second external measurement channel (connected to pins 4 and 5). If REN2 = '1', the second external channel is enabled; if REN2 = '0', the second external channel is disabled. The temperature measurement sequence is local channel, external channel 1, external channel 2, shutdown, and delay (to set conversion rate, if necessary). The sequence starts over with the local channel. If any of the channels are disabled, they are skipped in the sequence. Table 8 summarizes the bits of Configuration Register 2. Table 8. Configuration Register 2 Bit Descriptions CONFIGURATION REGISTER 2 (Read/Write = 1A for TMP431 3F for TMP432; POR = 1Ch for TMP431; 3Ch for TMP432) 20 BIT NAME FUNCTION 7, 6 Reserved — 0 5 REN2 0 = External channel 2 disabled 1 = External channel 2 enabled 1 (TMP432) 0 (TMP431) 4 REN 0 = External channel 1 disabled 1 = External channel 1 enabled 1 3 LEN 0 = Local channel disabled 1 = Local channel enabled 1 2 RC 0 = Resistance correction disabled 1 = Resistance correction enabled 1 1, 0 Reserved — 0 Submit Documentation Feedback POWER-ON RESET VALUE © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Conversion Rate Register The Conversion Rate Register (pointer address 0Ah) controls the rate at which temperature conversions are performed. This register adjusts the idle time between conversions but not the conversion timing itself, thereby allowing the TMP431/32 power dissipation to be balanced with the temperature register update rate. Table 9 shows the conversion rate options and corresponding current consumption. One-Shot Conversions TMP431/32 return to shutdown mode when that conversion completes. The value of the data sent in the write command is irrelevant and is not stored by the TMP431/32. When the TMP431/32 are in shutdown mode, an initial 200ps is required before a one-shot command can be given. (Note: When a shutdown command is issued, the TMP431/32 shut down immediately, aborting the current conversion.) This wait time only applies to the 200ps immediately following shutdown. One-shot commands can be issued without delay thereafter. When the TMP431/32 are in shutdown mode (SD = 1 in the Configuration Register 1), a single conversion on both channels is started by writing any value to the One-Shot Start Register, pointer address 0Fh. This write operation starts one conversion; the Table 9. Conversion Rate Register CONVERSION RATE REGISTER (Read = 04h, Write = 0Ah, POR = 07h) AVERAGE IQ (TYP) (μA) R7 R6 R5 R4 R3 R2 R1 R0 CONVERSION/SEC 0 0 0 0 0 0 0 0 0.0625 11 32 0 0 0 0 0 0 0 1 0.125 17 38 0 0 0 0 0 0 1 0 0.25 28 49 0 0 0 0 0 0 1 1 0.5 47 69 0 0 0 0 0 1 0 0 1 80 103 0 0 0 0 0 1 0 1 2 128 155 0 0 0 0 0 1 1 0 4 190 220 8 373 413 07h to 0Fh VS = 2.7V VS = 5.5V Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 21 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 Beta Compensation Configuration Register If the Beta Compensation Configuration Register is set to '1xxx' (beta correction enabled) for a given remote channel at the beginning of each temperature conversion, the TMP431/32 automatically detect if the sensor is diode-connected or GND collector-connected, select the proper beta range, and measure the sensor temperature appropriately. If the Beta Compensation Configuration Register is set to '0111' (beta correction disabled) for a given channel, the automatic detection is bypassed and the temperature is measured assuming a diode-connected sensor. A PNP transistor may www.ti.com continue to be GND collector-connected in this mode, but no beta compensation factor is applied. When the beta correction is set to '0111' or the sensor is diode-connected (base shorted to collector), the η-factor used by the TMP431/32 is 1.008. When the beta correction configuration is set to '1xxx' (beta correction enabled) and the sensor is GND collector-connected (PNP collector to ground), the η-factor used by the TMP431/32 is 1.000. Table 10 shows the read value for the selected beta ranges and the appropriate η-factor used for each conversion. Table 10. Beta Compensation Configuration Register η-FACTOR TIME 1000 Automatically selected range 0 (0.10 < beta < 0.18) 1.000 126ms 1001 Automatically selected range 1 (0.16 < beta < 0.26) 1.000 126ms 1010 Automatically selected range 2 (0.24 < beta < 0.43) 1.000 126ms 1011 Automatically selected range 3 (0.35 < beta < 0.78) 1.000 126ms 1100 Automatically selected range 4 (0.64 < beta < 1.8) 1.000 126ms 1101 Automatically selected range 5 (1.4 < beta < 9.0) 1.000 126ms 1110 Automatically selected range 6 (6.7 < beta < 40.0) 1.000 126ms 1111 Automatically selected range 7 (beta > 27.0) 1.000 126ms 1111 Automatically detected diode connected sensor 1.008 93ms 0000 Manually selected range 0 (0.10 < beta < 0.5) 1.000 93ms 0001 Manually selected range 1 (0.13 < beta < 1.0) 1.000 93ms 0010 Manually selected range 2 (0.18 < beta < 2.0) 1.000 93ms 0011 Manually selected range 3 (0.3 < beta < 25) 1.000 93ms 0100 Manually selected range 4 (0.5 < beta < 50) 1.000 93ms 0101 Manually selected range 5 (1.1 < beta < 100) 1.000 93ms 0110 Manually selected range 6 (2.4 < beta < 150) 1.000 93ms 0111 Manually disabled beta correction 1.008 93ms BCx3-BCx0 22 BETA RANGE DESCRIPTION Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com η-Factor Correction Register The TMP431/32 allow for a different η-factor value to be used for converting remote channel measurements to temperature. The remote channel uses sequential current excitation to extract a differential VBE voltage measurement to determine the temperature of the remote transistor. Equation 1 relates this voltage and temperature. I2 hkT VBE2 - VBE1 = ln q I1 (1) ( ) The value η in Equation 1 is a characteristic of the particular transistor used for the remote channel. When the beta compensation configuration is set to '0111' (beta compensation disabled) or the sensor is diode-connected (base shorted to collector), the η-factor used by the TMP431/32 is 1.008. When the beta compensation configuration is set to '1000' (beta compensation enabled) and the sensor is GND collector-connected (PNP collector to ground), the η-factor used by the TMP431/32 is 1.000. If the η-factor used for the temperature conversion does not match the characteristic of the sensor, then temperature offset is observed. The value in the η-Factor Correction Register may be used to adjust the effective η-factor according to Equation 2 and Equation 3 for disabled beta compensation or a diode-connected sensor. Equation 4 and Equation 5 may be used for enabled beta compensation and a GND collector-connected sensor. 1.008 ´ 300 heff = 300 - NADJUST (2) NADJUST = 300 - 300 ´ 1.008 heff (3) 1.000 ´ 300 heff = 300 - NADJUST (4) 300 ´ 1.000 NADJUST = 300 heff (5) The η-correction value must be stored in twos-complement format, yielding an effective data range from –128 to +127. Table 11 shows the η-factor range for both 1.008 and 1.000. For the TMP431, the η-correction value may be written to and read from pointer address 18h. For the TMP432, the η-correction value may be written to and read from pointer address 27h. The η-correction value for the second remote channel is read to and written from pointer address 28h. The register power-on reset value is 00h, thus having no effect unless written to. Table 11. η-Factor Range NADJUST BINARY HEX DECIMAL η 01111111 7F 127 1.747977 00001010 0A 10 1.042759 00001000 08 8 1.035616 00000110 06 6 1.028571 00000100 04 4 1.021622 00000010 02 2 1.014765 00000001 01 1 1.011371 00000000 00 0 1.008 11111111 FF –1 1.004651 11111110 FE –2 1.001325 11111100 FC –4 0.994737 11111010 FA –6 0.988235 11111000 F8 –8 0.981818 11110110 F6 –10 0.975484 10000000 80 –128 0.706542 space Software Reset The TMP431/32 may be reset by writing any value to Pointer Register FCh. This action restores the power-on reset state to all of the TMP431/32 registers as well as abort any conversion in process and clear the ALERT and THERM pins. The TMP431/32 also support reset via the two-wire general call address (00000000). The TMP431/32 acknowledge the general call address and respond to the second byte. If the second byte is 00000110, the TMP431/32 execute a software reset. The TMP431/32 do not respond to other values in the second byte. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 23 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Consecutive Alert Register Identification Registers The value in the Consecutive Alert Register (address 22h) determines how many consecutive out-of-limit measurements must occur on a measurement channel before the ALERT or the THERM signal is activated. The value in this register does not affect bits in the Status Register. Values of one, two, three, or four consecutive conversions can be selected; one conversion is the default. This function allows additional filtering for the ALERT or the THERM pin. Table 14 shows the consecutive alert bits. For bit descriptions, refer to Table 12. The TMP431/32 allow for the Two-Wire bus controller to query the device for manufacturer and device IDs to enable the device for software identification of the device at the particular Two-Wire bus address. The manufacturer ID is obtained by reading from pointer address FEh. The TMP431/32 both return 55h for the manufacturer code. The device ID is obtained by reading from pointer address FDh. The TMP431 returns 31h for the device ID and the TMP432 returns 32h for the device ID (see Table 3 and Table 4). These registers are read-only. Table 12. Consecutive Alert Register Bit Descriptions Table 13. Allowable THERM Hysteresis Values THERM HYSTERESIS VALUE BIT NAME NUMBER OF CONSECUTIVE OUT-OF-LIMIT MEASUREMENTS CALT2/CTH2 CALT1/CTH1 CALT0/CTH0 (ALERT/THERM) 0 0 0 0 0 1 TEMPERATURE (°C) TH[7:0] (STANDARD BINARY) (HEX) 0 0000 0000 00 1 1 0000 0001 01 2 5 0000 0101 05 0000 1010 0A 19 0 1 1 3 10 1 1 1 4 25 0001 1001 50 0011 0010 32 75 0100 1011 4B 100 0110 0100 64 125 0111 1101 7D 127 0111 1111 7F 150 1001 0110 96 175 1010 1111 AF 200 1100 1000 C8 225 1110 0001 E1 255 1111 1111 FF . Therm Hysteresis Register The THERM Hysteresis Register, shown in Table 15, stores the hysteresis value used for the THERM pin alarm function. This register must be programmed with a value that is less than the Local Temperature High Limit Register value, Remote Temperature High Limit Register value, Local THERM Limit Register value, or Remote THERM Limit Register value; otherwise, the respective temperature comparator does not trip on the measured temperature falling edges. Allowable hysteresis values are shown in Table 13. The default hysteresis value is 10°C, whether the device is operating in the standard or extended mode setting. Table 14. Consecutive Alert Register Format CONSECUTIVE ALERT REGISTER (READ = 22h, WRITE = 22h, POR = 70h) BIT # D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME 0 CTH2 CTH1 CTH0 CALT2 CALT1 CALT0 0 POR VALUE 0 1 1 1 0 0 0 0 Table 15. THERM Hysteresis Register Format THERM HYSTERESIS REGISTER (Read = 21h, Write = 21h, POR = 0Ah) BIT # BIT NAME POR VALUE 24 D7 D6 D5 D4 D3 D2 D1 D0 TH7 TH6 TH5 TH4 TH3 TH2 TH1 TH0 0 0 0 0 1 0 1 0 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Bus Overview Read/Write Operations The TMP431/32 are SMBus interface-compatible. In SMBus protocol, the device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. Accessing a particular register on the TMP431/32 is accomplished by writing the appropriate value to the Pointer Register. The value for the Pointer Register is the first byte transferred after the slave address byte with the R/W bit low. Every write operation to the TMP431/32 require a value for the Pointer Register (see Figure 17). To address a specific device, a START condition is initiated. START is indicated by pulling the data line (SDA) from a high to low logic level while SCL is high. All slaves on the bus shift in the slave address byte, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an Acknowledge and pulling SDA low. Once all data have been transferred, the master generates a STOP condition. STOP is indicated by pulling SDA from low to high, while SCL is high. When reading from the TMP431/32, the last value stored in the Pointer Register by a write operation is used to determine which register is read by a read operation. To change the register pointer for a read operation, a new value must be written to the Pointer Register. This transaction is accomplished by issuing a slave address byte with the R/W bit low, followed by the Pointer Register byte. No additional data are required. The master can then generate a START condition and send the slave address byte with the R/W bit high to initiate the read command. See Figure 18 for details of this sequence. If repeated reads from the same register are desired, it is not necessary to continually send the Pointer Register bytes, because the TMP431/32 retain the Pointer Register value until it is changed by the next write operation. Note that register bytes are sent MSB first, followed by the LSB. Serial Interface TIMING DIAGRAMS The TMP431/32 operate only as slave devices on either the Two-Wire bus or the SMBus. Connections to either bus are made via the open-drain I/O lines, SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The TMP431/32 support the transmission protocol for fast (1kHz to 400kHz) and high-speed (1kHz to 3.4MHz) modes. All data bytes are transmitted MSB first. The TMP431/32 are Two-Wire and SMBus-compatible. Figure 16 to Figure 20 describe the various operations on the TMP431/32. Bus definitions are given below. Parameters for Figure 16 are defined in Table 16. Data transfer is then initiated and sent over eight clock pulses followed by an Acknowledge bit. During data transfer SDA must remain stable while SCL is high, because any change in SDA while SCL is high is interpreted as a control signal. Serial Bus Address To communicate with the TMP431/32, the master must first address slave devices via a slave address byte. The slave address byte consists of seven address bits, and a direction bit that indicates the intent of executing a read or write operation. The address of the TMP431A/32A/31C is 4Ch (1001100b). The address of the TMP431B/32B/31D is 4Dh (1001101b). Bus Idle: Both SDA and SCL lines remain high. Start Data Transfer: A change in the state of the SDA line, from high to low, while the SCL line is high, defines a START condition. Each data transfer is initiated with a START condition. Stop Data Transfer: A change in the state of the SDA line from low to high while the SCL line is high defines a STOP condition. Each data transfer terminates with a STOP or a repeated START condition. Data Transfer: The number of data bytes transferred between a START and a STOP condition is not limited and is determined by the master device. The receiver acknowledges the transfer of data. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 25 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Acknowledge: Each receiving device, when addressed, is obliged to generate an Acknowledge bit. A device that acknowledges must pull down the SDA line during the Acknowledge clock pulse in such a way that the SDA line is stable low during the high t(LOW) period of the Acknowledge clock pulse. Setup and hold times must be taken into account. On a master receive, data transfer termination can be signaled by the master generating a Not-Acknowledge on the last byte that has been transmitted by the slave. tF tR t(HDSTA) SCL t(HDSTA) t(HIGH) t(HDDAT) t(SUSTO) t(SUSTA) t(SUDAT) SDA t(BUF) P S S P Figure 16. Two-Wire Timing Diagram Table 16. Timing Diagram Definitions for Figure 16 FAST MODE PARAMETER HIGH-SPEED MODE MIN MAX MIN MAX UNITS SCL Operating Frequency f(SCL) 0.001 0.4 0.001 3.4 MHZ Bus Free Time Between STOP and START Condition t(BUF) 600 160 Hold time after repeated START condition. After this period, the first clock is generated. t(HDSTA) 100 100 ns Repeated START Condition Setup Time t(SUSTA) 100 100 ns STOP Condition Setup Time t(SUSTO) 100 100 ns Data Hold Time t(HDDAT) 0 (1) 0 (2) ns Data Setup Time ns t(SUDAT) 100 10 ns SCL Clock LOW Period t(LOW) 1300 160 ns SCL Clock HIGH Period t(HIGH) 600 60 ns Clock/Data Fall Time Clock/Data Rise Time for SCLK ≤ 100kHz (1) (2) 26 tF tR 300 160 ns 300 160 ns 1000 ns For cases with fall time of SCL less than 20ns and/or the rise time or fall time of SDA less than 20ns, the hold time should be greater than 20ns. For cases with fall time of SCL less than 10ns and/or the rise or fall time of SDA less than 10ns, the hold time should be greater than 10ns. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com 1 9 9 1 SCL ¼ 1 SDA 0 0 1 1 0 0(1) Start By Master P7 R/W P6 P5 P4 P3 P2 ACK By TMP431A/32A/31C P1 P0 ¼ ACK By TMP431A/32A/31C Frame 2 Pointer Register Byte Frame 1 Two- Wire Slave Address Byte 9 1 1 9 SCL (Continued) SDA (Continued) D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 ACK By Stop By TMP431A/32A/ Master 31C ACK By TMP431A/32A/31C Frame 4 Data Byte 2 Frame 3 Data Byte 1 NOTE (1): Slave address 1001100 (TMP431A/32A/31C) shown. Slave address changes for TMP431B/32B/31D. See Ordering Information table for more details. Figure 17. Two-Wire Timing Diagram for Write Word Format 1 9 1 9 SCL SDA 1 0 0 1 1 0 0(1) Start By Master R/W P7 P6 P5 P4 P3 P2 P1 ACK By TMP431A/32A/31C ACK By TMP431A/32A/31C Frame 1 Two-Wire Slave Address Byte 1 P0 Frame 2 Pointer Register Byte 9 1 9 SCL (Continued) SDA (Continued) 1 0 0 1 Start By Master 1 0 0(1) R/W D7 D6 D5 D4 ACK By TMP431A/32A/31C Frame 3 Two-Wire Slave Address Byte D3 D2 D1 D0 From TMP431A/32A/31C NACK By Master(2) Frame 4 Data Byte 1 Read Register NOTES: (1) Slave address 1001100 (TMP431A/32A/31C) shown. Slave address changes for TMP431B/32B/31D. See Ordering Information table for more details. (2) Master should leave SDA high to terminate a single-byte read operation. Figure 18. Two-Wire Timing Diagram for Single-Byte Read Format Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 27 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com 1 9 1 9 SCL SDA 0 1 0 1 1 0(1) 0 Start By Master R/W P7 P6 P5 P4 P3 P2 P1 ACK By TMP431A/32A/31C P0 ACK By TMP431A/32A/31C Frame 1 Two-Wire Slave Address Byte Frame 2 Pointer Register Byte 1 9 1 9 SCL (Continued) SDA (Continued) 1 0 0 1 1 0(1) 0 Start By Master D7 R/W D6 D5 D4 D3 ACK By TMP431A/32A/31C D1 D0 From TMP431A/32A/31C Frame 3 Two-Wire Slave Address Byte 1 D2 ACK By Master Frame 4 Data Byte 1 Read Register 9 SCL (Continued) SDA (Continued) D7 D6 D5 D4 D3 D2 D1 D0 From TMP431A/32A/31C NACK By Master(2) Stop By Master Frame 5 Data Byte 2 Read Register NOTES: (1) Slave address 1001100 (TMP431A/32A/31C) shown. Slave address changes for TMP431B/32B/31D. See Ordering Information table for more details. (2) Master should leave SDA high to terminate a two-byte read operation. Figure 19. Two-Wire Timing Diagram for Two-Byte Read Format ALERT 1 9 1 9 SCL SDA 0 0 0 1 1 Start By Master 0 0 R/W 1 ACK By TMP431A/32A/31C Frame 1 SMBus ALERT Response Address Byte 0 0 1 1 0 0 (1) Status From NACK By TMP431A/32A/31C Master Stop By Master Frame 2 Slave Address Byte NOTE (1): Slave address 1001100 (TMP431A/32A/31C) shown. Slave address changes for TMP431B/32B/31D. See Ordering Information table for more details. Figure 20. Timing Diagram for SMBus ALERT 28 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com High-Speed Mode In order for the Two-Wire bus to operate at frequencies above 400kHz, the master device must issue a High-speed mode (Hs-mode) master code (00001XXX) as the first byte after a START condition to switch the bus to high-speed operation. The TMP431/32 do not acknowledge this byte, but switch the input filters on SDA and SCL and the output filter on SDA to operate in Hs-mode, allowing transfers at up to 3.4MHz. After the Hs-mode master code has been issued, the master transmits a Two-Wire slave address to initiate a data transfer operation. The bus continues to operate in Hs-mode until a STOP condition occurs on the bus. Upon receiving the STOP condition, the TMP431/32 switch the input and output filter back to fast-mode operation. Timeout Function The serial interface of the TMP431/32 resets if either SCL or SDA are held low for 32ms (typical) between a START and STOP condition. If the TMP431/32 are holding the bus low, it releases the bus and waits for a START condition. THERM and ALERT/THERM2 The TMP431/32 have two pins dedicated to alarm functions, the THERM and ALERT/THERM2 pins. Both pins are open-drain outputs that each require a pull-up resistor to V+. These pins can be wire-ORed together with other alarm pins for system monitoring of multiple sensors. The THERM pin provides a thermal interrupt that cannot be software disabled. The ALERT pin is intended for use as an earlier warning interrupt, and can be software disabled, or masked. The ALERT/THERM2 pin can also be configured for use as THERM2, a second THERM pin (Configuration Register 1: AL/TH bit = 1). The default setting configures pin 6 for the TMP431 and pin 8 for the TMP432 to function as ALERT (AL/TH = 0). The THERM pin asserts low when either the measured local or remote temperature is outside of the temperature range programmed in the corresponding Local/Remote THERM Limit Register. The THERM temperature limit range can be programmed with a wider range than that of the limit registers, which allows ALERT to provide an earlier warning than THERM. The THERM alarm resets automatically when the measured temperature returns to within the THERM temperature limit range minus the hysteresis value stored in the THERM Hysteresis Register. The allowable values of hysteresis are shown in Table 13. The default hysteresis is 10°C. When the ALERT/THERM2 pin is configured as a second thermal alarm (Configuration Register: bit 7 = x, bit 5 = 1), it functions the same as THERM, but uses the temperatures stored in the Local/Remote Temperature High Limit Registers to set its comparison range. When ALERT/THERM2 is configured as ALERT (Configuration Register 1: bit 7 = 0, bit 5 = 0), the pin asserts low when either the measured local or remote temperature violates the range limit set by the corresponding Local/Remote Temperature High/Low Limit Registers. This alert function can be configured to assert only if the range is violated a specified number of consecutive times (1, 2, 3, or 4). The consecutive violation limit is set in the Consecutive Alert Register. False alerts that occur as a result of environmental noise can be prevented by requiring consecutive faults. ALERT also asserts low if the remote temperature sensor is open-circuit. When the MASK function is enabled (Configuration Register 1: bit 7 = 1), ALERT is disabled (that is, masked). ALERT resets when the master reads the device address, as long as the condition that caused the alert no longer persists, and the Status Register has been reset. SMBus Alert Function The TMP431/32 support the SMBus Alert function. When pin 6 (for the TMP431) or pin 8 (for the TMP432) is configured as an alert output, the ALERT pin of the TMP431/32 may be connected as an SMBus Alert signal. When a master detects an alert condition on the ALERT line, the master sends an SMBus Alert command (00011001) on the bus. If the ALERT pin of the TMP431/32 is active, the devices acknowledge the SMBus Alert command and respond by returning the slave address on the SDA line. The eighth bit (LSB) of the slave address byte indicates whether the temperature exceeding one of the temperature high limit settings or falling below one of the temperature low limit settings caused the alert condition. This bit is high if the temperature is greater than or equal to one of the temperature high limit settings; this bit is low if the temperature is less than one of the temperature low limit settings. See Figure 21 for details of this sequence. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 29 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com THERM Limit and ALERT High Limit Measured Temperature ALERT Low Limit and THERM Limit Hysteresis THERM ALERT SMBus ALERT Read Read Read Time Figure 21. SMBus Alert Timing Diagram If multiple devices on the bus respond to the SMBus Alert command, arbitration during the slave address portion of the SMBus Alert command determines which device clears its alert status. If the TMP431/32 win the arbitration, the ALERT pin becomes inactive at the completion of the SMBus Alert command. If the TMP431/32 lose the arbitration, the ALERT pin remains active. Shutdown Mode (SD) The TMP431/32 shutdown mode allows the user to save maximum power by shutting down all device circuitry other than the serial interface, reducing current consumption to typically less than 3µA; see typical characteristic curve Shutdown Quiescent Current vs Supply Voltage (Figure 6). Shutdown mode is enabled when the SD bit of the Configuration Register 1 is high; the device shuts down immediately, aborting the current conversion. When SD is low, the device maintains a continuous conversion state. Sensor Fault The TMP431/32 can sense a fault at the DXP input that results from an incorrect diode connection or an open circuit. The detection circuitry consists of a voltage comparator that trips when the voltage at DXP exceeds (V+) – 0.6V (typical). The comparator output is continuously checked during a conversion. If a fault is detected, the last valid measured temperature is used for the temperature measurement result, the OPEN bit (Status Register, bit 2) is set high, and, if the alert function is enabled, ALERT asserts low. When not using the remote sensor with the TMP431/32, the DXP and DXN inputs must be connected together to prevent meaningless fault warnings. 30 Undervoltage Lockout The TMP431/32 sense when the power-supply voltage has reached a minimum voltage level for the ADC to function. The detection circuitry consists of a voltage comparator that enables the ADC after the power supply (V+) exceeds 2.45V (typical). The comparator output is continuously checked during a conversion. The TMP431/32 do not perform a temperature conversion if the power supply is not valid. The last valid measured temperature is used for the temperature measurement result. General Call Reset The TMP431/32 support reset via the Two-Wire General Call address 00h (0000 0000b). The TMP431/32 acknowledge the General Call address and respond to the second byte. If the second byte is 06h (0000 0110b), the TMP431/32 execute a software reset. This software reset restores the power-on reset state to all TMP431/32 registers, aborts any conversion in progress, and clears the ALERT and THERM pins. The TMP431/32 take no action in response to other values in the second byte. Filtering Remote junction temperature sensors are usually implemented in noisy environments. Noise is frequently generated by fast digital signals and if not filtered properly can induce errors that corrupt temperature measurements. The TMP431/32 have a built-in 65kHz filter on the inputs of DXP and DXN to minimize the effects of noise. However, a differential low-pass filter can help attenuate unwanted coupled signals. Exact component values are application-specific. It is also recommended that the capacitor value remains between 0pF to 2200pF with a series resistance less than 1kΩ. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Remote Sensing The TMP431/32 are designed to be used with either discrete transistors or substrate transistors built into processor chips and ASICs. Either NPN- or PNP-type transistors can be used, as long as the base-emitter junction is used as the remote temperature sense. NPN transistors must be diode-connected. PNP transistors can either be transistor- or diodeconnected (see Figure 13). Errors in remote temperature sensor readings are typically the consequence of the ideality factor and current excitation used by the TMP431/32 versus the manufacturer-specified operating current for a given transistor. Some manufacturers specify a high-level and low-level current for the temperature-sensing substrate transistors. The TMP431/32 use 6μA for ILOW and 120μA for IHIGH. The TMP431/32 allow for different η-factor values; see the η- Factor Correction Register section. The ideality factor (η) is a measured characteristic of a remote temperature sensor diode as compared to an ideal diode. The ideality factor for the TMP431/32 is trimmed to be 1.008. For transistors whose ideality factor does not match the TMP431/32, Equation 6 can be used to calculate the temperature error. Note that for the equation to be used correctly, actual temperature (°C) must be converted to Kelvin (K). h - 1.008 TERR = ´ [273.15 + T(°C)] 1.008 ) ( Where: • • • η = Ideality factor of remote temperature sensor T(°C) = actual temperature TERR = Error in TMP431/32 reading due to η ≠ 1.008 Degree delta is the same for °C and K (6) • For n = 1.004 and T(°C) = 100°C: 1.004 - 1.008 TERR = ´ (273.15 + 100°C) 1.008 ( ) TERR = 1.48°C (7) If a discrete transistor is used as the remote temperature sensor with the TMP431/32, the best accuracy can be achieved by selecting the transistor according to the following criteria: 1. Base-emitter voltage > 0.25V at 6μA, at the highest sensed temperature. 2. Base-emitter voltage < 0.95V at 120μA, at the lowest sensed temperature. 3. Base resistance < 100Ω. 4. Tight control of VBE characteristics indicated by small variations in hFE (that is, 50 to 150). Based on these criteria, two recommended small-signal transistors are the 2N3904 (NPN) or 2N3906 (PNP). Measurement Accuracy and Thermal Considerations The temperature measurement accuracy of the TMP431/32 depends on the remote and/or local temperature sensor being at the same temperature as the system point being monitored. Clearly, if the temperature sensor is not in good thermal contact with the part of the system being monitored, then there will be a delay in the response of the sensor to a temperature change in the system. For remote temperature sensing applications that use a substrate transistor (or a small, SOT23 transistor) placed close to the device being monitored, this delay is usually not a concern. The local temperature sensor inside the TMP431/32 monitors the ambient air around the device. The thermal time constant for the TMP431/32 is approximately 2 seconds. This constant implies that if the ambient air changes quickly by 100°C, it would take the TMP431/32 about 10 seconds (that is, five thermal time constants) to settle to within 1°C of the final value. In most applications, the TMP431/32 package is in thermal contact with the printed circuit board (PCB), as well as subjected to forced airflow. The accuracy of the measured temperature directly depends on how accurately the PCB and forced airflow temperatures represent the temperature that the TMP431/32 is measuring. Additionally, the internal power dissipation of the TMP431/32 can cause the temperature to rise above the ambient or PCB temperature. The internal power dissipated as a result of exciting the remote temperature sensor is negligible because of the small currents used. For a 5.5V supply and maximum conversion rate of eight conversions per second, the TMP431/32 dissipate 1.82mW (PDIQ = 5.5V × 330μA). If both the ALERT/THERM2 and THERM pins are each sinking 1mA, an additional 0.8mW is dissipated (PDOUT = 1mA × 0.4V + 1mA × 0.4V = 0.8mW). Total power dissipation is then 2.62mW (PDIQ + PDOUT) and, with an θJA of 150°C/W, causes the junction temperature to rise approximately 0.393°C above the ambient. Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 31 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com Layout Considerations Remote temperature sensing on the TMP431/32 measures very small voltages using very low currents; therefore, noise at the IC inputs must be minimized. Most applications using the TMP431/32 have high digital content, with several clocks and logic level transitions creating a noisy environment. Layout should conform to the following guidelines: 1. Place the TMP431/32 as close to the remote junction sensor as possible. 2. Route the DXP and DXN traces next to each other and shield them from adjacent signals through the use of ground guard traces, as shown in Figure 22. If a multilayer PCB is used, bury these traces between ground or VDD planes to shield them from extrinsic noise sources. 5 mil (0,127 mm) PCB traces are recommended. 3. Minimize additional thermocouple junctions caused by copper-to-solder connections. If these junctions are used, make the same number and approximate locations of copper-to-solder connections in both the DXP and DXN connections to cancel any thermocouple effects. 4. Use a 0.1μF local bypass capacitor directly between the V+ and GND of the TMP431/32. Figure 23 shows the suggested bypass capacitor placement for the TMP431/32. This capacitance includes any cable capacitance between the remote temperature sensor and TMP431/32. 5. If the connection between the remote temperature sensor and the TMP431/32 is less than 8 inches (20,32 cm), use a twisted-wire pair connection. Beyond 8 inches, use a twisted, shielded pair with the shield grounded as close to the TMP431/32 as possible. Leave the remote sensor connection end of the shield wire open to avoid ground loops and 60Hz pickup. 6. Thoroughly clean and remove all flux residue in and around the pins of the TMP431/32 to avoid temperature offset readings as a result of leakage paths between DXP or DXN and GND, or between DXP or DXN and V+. V+ DXP Ground or V+ layer on bottom and/or top, if possible. DXN GND Note: Use 5 mil (.005 in, or 0,127 mm) traces with 5 mil (.005 in, or 0,127 mm) spacing. Figure 22. Example Signal Traces 0.1mF Capacitor V+ GND PCB Via 1 8 DXP 2 7 DXN 3 6 4 5 PCB Via TMP431 0.1mF Capacitor V+ GND PCB Via 1 10 DXP1 2 9 DXN1 3 8 DXP2 4 7 DXN2 5 6 PCB Via TMP432 Figure 23. Suggested Bypass Capacitor Placement 32 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 TMP431 TMP432 SBOS441C – SEPTEMBER 2009 – REVISED FEBRUARY 2011 www.ti.com REVISION HISTORY NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision B (April, 2010) to Revision C Page • Added Therm high limit column to Package Information table ............................................................................................. 2 • Added TMP431C, TMP431D device information .................................................................................................................. 2 • Added footnote (4) to TMP431 Register Map ..................................................................................................................... 13 • Revised information about power-on reset value of THERM limit registers in Limit Registers section .............................. 16 • Updated Serial Bus Address section for TMP431C/TMP431D device versions ................................................................ 25 • Revised Figure 17 ............................................................................................................................................................... 27 • Updated Figure 18 .............................................................................................................................................................. 27 • Changed Figure 19 ............................................................................................................................................................. 28 • Revised Figure 20 ............................................................................................................................................................... 28 Changes from Revision A (November, 2009) to Revision B • Page Corrected Equation 7 .......................................................................................................................................................... 31 Submit Documentation Feedback © 2009–2011, Texas Instruments Incorporated Product Folder Link(s): TMP431 TMP432 33 PACKAGE OPTION ADDENDUM www.ti.com 16-Aug-2012 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead/ Ball Finish MSL Peak Temp (3) TMP431ADGKR ACTIVE VSSOP DGK 8 2500 Green (RoHS & no Sb/Br) CU NIPDAUAGLevel-2-260C-1 YEAR TMP431ADGKT ACTIVE VSSOP DGK 8 250 Green (RoHS & no Sb/Br) CU NIPDAUAGLevel-2-260C-1 YEAR TMP431BDGKR ACTIVE VSSOP DGK 8 2500 Green (RoHS & no Sb/Br) CU NIPDAUAGLevel-2-260C-1 YEAR TMP431BDGKT ACTIVE VSSOP DGK 8 250 Green (RoHS & no Sb/Br) CU NIPDAUAGLevel-2-260C-1 YEAR TMP431CDGKR ACTIVE VSSOP DGK 8 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP431CDGKT ACTIVE VSSOP DGK 8 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP431DDGKR ACTIVE VSSOP DGK 8 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP431DDGKT ACTIVE VSSOP DGK 8 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP432ADGSR ACTIVE MSOP DGS 10 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP432ADGST ACTIVE MSOP DGS 10 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP432BDGSR ACTIVE MSOP DGS 10 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TMP432BDGST ACTIVE MSOP DGS 10 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR Samples (Requires Login) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Addendum-Page 1 PACKAGE OPTION ADDENDUM www.ti.com 16-Aug-2012 Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 16-Aug-2012 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing TMP431ADGKR VSSOP DGK 8 SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431ADGKT VSSOP DGK 8 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431BDGKR VSSOP DGK 8 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431BDGKT VSSOP DGK 8 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431CDGKR VSSOP DGK 8 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431CDGKT VSSOP DGK 8 250 177.8 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431DDGKR VSSOP DGK 8 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP431DDGKT VSSOP DGK 8 250 177.8 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432ADGSR MSOP DGS 10 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432ADGSR MSOP DGS 10 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432ADGST MSOP DGS 10 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432ADGST MSOP DGS 10 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432BDGSR MSOP DGS 10 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432BDGSR MSOP DGS 10 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432BDGST MSOP DGS 10 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 TMP432BDGST MSOP DGS 10 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 16-Aug-2012 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) TMP431ADGKR VSSOP DGK 8 2500 366.0 364.0 50.0 TMP431ADGKT VSSOP DGK 8 250 366.0 364.0 50.0 TMP431BDGKR VSSOP DGK 8 2500 366.0 364.0 50.0 TMP431BDGKT VSSOP DGK 8 250 366.0 364.0 50.0 TMP431CDGKR VSSOP DGK 8 2500 358.0 335.0 35.0 TMP431CDGKT VSSOP DGK 8 250 202.0 201.0 28.0 TMP431DDGKR VSSOP DGK 8 2500 358.0 335.0 35.0 TMP431DDGKT VSSOP DGK 8 250 202.0 201.0 28.0 TMP432ADGSR MSOP DGS 10 2500 358.0 335.0 35.0 TMP432ADGSR MSOP DGS 10 2500 366.0 364.0 50.0 TMP432ADGST MSOP DGS 10 250 366.0 364.0 50.0 TMP432ADGST MSOP DGS 10 250 358.0 335.0 35.0 TMP432BDGSR MSOP DGS 10 2500 358.0 335.0 35.0 TMP432BDGSR MSOP DGS 10 2500 366.0 364.0 50.0 TMP432BDGST MSOP DGS 10 250 358.0 335.0 35.0 TMP432BDGST MSOP DGS 10 250 366.0 364.0 50.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46C and to discontinue any product or service per JESD48B. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such components to meet such requirements. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated