PERKINELMER U1160

|
Sensors
|
D A T A S H E E T
Sensor systems
Lighting
p
Oil Burner Control Applications
Photocells U 1160
small Photocell
Glass encapsulated housing
Oil Burner Controls Applications
This glass encapsulated photocell is the main running series for the above
mentioned burner control application range. Customized selections are
available upon request.
Operating Temperature Range: -20...+70 °C (non continuous)
Storage Temperature Range: -20...+80 °C (non continuous)
Ty pe
R 10
R 100
units
KW
U 1160 12
20...50
8,0
0,12
0,36
150
50
0,7
550
U 1160 13
35...220
15
0,4
1,2
150
50
0,85
550
U 1160 14
150...1000
35
1,0
3,0
150
50
0,95
550
U 1160 32
100...320
40
1,0
3,0
400
50
0,7
550
U 1160 33
250...1100
75
2,0
6,0
400
50
0,85
550
KW
ty p.
R 01
MW
min
R 05
MW
min
Vmax
Pmax
g 10/100
l p eak
V
mW
ty p.
nm
all Dimensions
in mm
Europe:
PerkinElmer Optoelectronics
GmbH & CoKG
Wenzel Jaksch Str 31
65199 Wiesbaden / Germany
Phone +49(0)611 492 0
Fax
+49(0)611 492 170
USA:
PerkinElmer Optoelectronics
44370 Christy Street
Freemont, CA 94538-3180
Phone +510 979 6500
+800 775 6786
Fax
+510 687 1140
Asia:
PerkinElmer Optoelectronics
47, Ayer Rajah Crescent #06-12
Singapore 139947
Phone +65 775 2022
Fax
+65 775 1008
Right for modification reserved / WS / 28.8.2003