ETC UDM40LSXSXR2HTX

Digital Panel Meters
Modular Indicator and Controller
Type UDM40
•
•
•
•
•
•
•
• The alarm status can be coupled to the different
colour of the display
• Linearization of V and A inputs up to 16 points
•
•
•
•
•
•
Multi-input modular instrument 4 dgt LED
0.1% RDG basic accuracy
TRMS AC current and voltage measurements
AC/DC current measurements; selectable full scales
(200µA to 5A)
AC/DC voltage measurements; selectable full scales
(200mV to 500V)
°C or °F temperature measurements
(Pt100-250-500-1000, Ni100, TC J-K-S-T-E)
Resistance measurements; selectable full scales
(20Ω to 20kΩ)
Up to 4 independent alarm set-points (optional)
20mA/10VDC analog output (optional)
Serial port RS485 or RS232 (optional)
MODBUS, JBUS communication protocol
Front protection degree: IP67, NEMA4x
LED display, selectable colour (red, amber, green)
Product Description
How to order
digital
panel
µp-based
meter, 4-dgt LED indicator,
for current, voltage, temperature and resistance measurements.
Measuring
ranges and functions easily
programmable from the keypad or from the PC by
Model
Slot A
Slot B
Slot C
Slot D
Options
means of optional UdmSoft
software. UDM40 includes
storage min-max functions
and double level protection
password. Housing for panel
mounting with front protection degree: IP67, NEMA4x.
How to order
UDM40 XXX XX XX X XX
UdmSoft-kit
UdmSoft-kit: software plus “UCOM1” communication cable for
programming UDM40 by means of PC .
Type Selection
Slot A (measuring inputs)
Slot B (communication)
Slot C (communication and alarm)
Slot D (power supply)
LSX: signal inputs:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
LSE/
LSF: signal inputs: + AUX:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
HSX: signal inputs:
0.2-2-5A DC/AC;
20-200-500V DC/AC
TRX: signal inputs: TC temperature probes (J-KS-T-E, Pt100-250-5001000) and resistance
(0.02-0.2-2-20kΩ)
XX:
SX:
SY:
AV(*):
None
Serial port RS485
Serial port RS232
Single analogue output,
0 to 20mA DC and
0 to 10V DC
XX:
R1:
H:
L:
(*):
The two analogue
outputs cannot be
used at the same
time. It is possible to
plug in only one
module by instrument.
None
Single relay output,
(AC1-8AAC, 250VAC)
R2:
Dual relay output,
(AC1-8AAC, 250VAC)
R4:
Dual relay output, (AC18AAC, 250VAC) + dual
open collector output
(NPN, 100mA)
R5:
4 relay outputs
(AC1-5AAC, 250VAC)
AV(*): Single analogue output,
0 to 20mA DC and
0 to 10V DC
90 to 260V AC/DC
18 to 60V AC/DC
Options
XX:
TX:
None
Tropicalization
Input Specifications
Analogue inputs
BQ LSX module
BQ LSE/LSF module
BQ HSX module
BQ TRX module
BQ TRX module
Digital inputs
Number of inputs
Use
Channels and variable
1, mA and V DC/AC
1, mA and V DC/AC + AUX
1, A and V DC/AC
1, temperature
1, resistance
Incl. in the measuring module
1 (voltage-free)
key-pad lock
Display hold
Reset of latch alarms
Specifications are subject to change without notice
Contact reading signal
Close contact resistance
Open contact resistance
Insulation
Accuracy (display, RS485)
UDM40DS 040706
BQ xxx: <0.1mA, <3,5V DC
BQ LSE/BQ LSF: <2.5mA,
<14V DC
Max 1kΩ
Min 500kΩ
Non-insulated
See table “Measuring
accuracy”, temperature drifts
and minimum-maximum
indications”
1
UDM40
Input specifications (cont.)
Additional errors
Humidity
Input frequency
Magnetic field
Temperature drift
Sampling rate
Display refresh time
Display
Colour
Max and min indication
Measurements
0.3% RDG, 60% to 90% R.H.
0.4% RDG, 62 to 440 Hz
0.5% RDG @ 400 A/m
See table “Measurement
accuracy, temperature drifts,
and max/min indications”
500 samples/s @ 50 Hz
200 msec @ 50Hz
4 DGT,
7 segments
height 14.2 mm
Selectable (red, amber,
green)
See table “Measurement
accuracy, temperature drifts
and max min indications”
Current, voltage, temperature
and resistance. For the current and voltage measurements: TRMS measurement
Coupling type
Crest factor
Input impedance
Frequency
Overload
Compensation
RTD
TC
of distorted sine waves.
Direct
≤3; APmax=1.7In; VPmax=1.7Un
See table “input
impedances and overloads”
40 to 440 Hz
See table “input
impedances and overloads”
Only temperature
measurement module.
- For Pt 100-250-500-1000,
3-wire connection: up to 10Ω
- For resistance measur. with
20Ω range: up to max 0.1Ω
- For resistance measurements
with ≥200Ωrange: up to max 10Ω
Internal cold junction, within
temperature range from
0 to +50°C.
Automatic or manual com-
Measurement accuracy, temp. drifts, max and min indications
All accuracies and min/max indications are referred to an ambient temp. range of 25°C ±5°C, rel. humidity ≤60% and scale ratio (electrical/displayed scale) equal to 1. The conversion into °F is obtained acting on the electrical/displayed scale ratio.
Module
Inputs
Type
Accuracy
BQ LSX/
BQ LSE/
BQ LSF
DC: ±(0.1%RDG+3DGT)
0% to 25% FS;
-200µA to +200µA
±(0.1%RDG+2DGT)
-2mA to +2mA
25% to 110% FS.
-20mA to +20mA
DC/AC TRMS (da 45 a 65Hz)*:
-200mV to +200mV
±(0.3%RDG+3DGT)
-2V to +2V
0% to 25% FS;
-20V to +20V
±(0.3%RDG+2DGT)
25% to 110% FS.
BQ HSX
DC: ±(0.1%RDG+3DGT)
0% to 25% FS;
-200mA to +200mA
±(0.1%RDG+2DGT)
-2A to +2A
25% to 110% FS.
-5A to +5A
DC/AC TRMS (45 to 65Hz)*:
-20V to +20V
±(0.3%RDG+3DGT)
-200V to +200V
0% to 25% FS;
-500V to +500V
±(0.3%RDG+2DGT)
25% to 110% FS.
BQ TRX
Thermocouple
-50°C to +760°C
-58 °F to +1400 °F
-200°C to +1260°C
-328 °F to +2300°F
-200°C to +1000°C
-328°F to +1832°F
-50°C to +1750°C
-58°F to +3182°F
-200°C to +400°C
-328°F to +752°F
*
(<)
2
J
J
K
K
E
E
S
S
T
T
±(0.2%RDG+1DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
Temp. drift
Min. indication (<)
Max. indicat. (<)
±150 ppm/°C
- 200.0
- 2.000
- 20.00
- 200.0
- 2.000
- 20.00
+ 200.0
+ 2.000
+ 20.00
+ 200.0
+ 2.000
+ 20.00
±150 ppm/°C
- 200.0
- 2.000
- 5.000
- 20.00
- 200.0
- 500.0
+ 200.0
+ 2.000
+ 5.000
+ 20.00
+ 200.0
+ 500.0
±150 ppm/°C
- 50°C
- 58°F
- 200°C
- 328°F
- 200°C
- 328°F
- 50°C
- 58°F
- 200°C
- 328°F
+ 760°C
+ 1400°F
+ 1260°C
+ 2300°F
+ 1000°C
+ 1832°F
+ 1750°C
+ 3182°F
+ 400°C
+ 752°F
<45Hz >65Hz= ±(0.5%RDG+3DGT) 0% to 25% FS; ±(0.5%RDG+2DGT) 25% to 110% FS.
The min. indication for TRMS measurement (AC or DC) is 0; it is possible to modify the decimal point position.
Specifications are subject to change without notice UDM40DS 040706
UDM40
Measurement accuracy, temp. drifts, min max indications (cont.)
All accuracies and min/max indications refer to an ambient temperature range of 25°C ±5°C, relevant humidity ≤60% and scale ratio (electrical scale / displayed scale) equal to 1. The conversion into °F is obtained acting on the electrical/displayed scale ratio.
Module
Inputs
Type
Accuracy
BQ TRX
Thermoresistance
-200°C to +850°C
-328°F to +1562°F
-200.0°C to +200.0°C
-328°F to+392°F
-200.0°C to +200.0°C
-328°F to +392°F
-200.0°C to +200.0°C
-328°F to +392°F
-200.0°C to +200.0°C
-328°F to +392°F
-60°C to +180°C
-76°F to +356°F
Pt100
Pt100
Pt100
Pt100
Pt250
Pt250
Pt500
Pt500
Pt1000
Pt1000
Ni100
Ni100
±(0.2%RDG +2DGT)
±(0.2%RDG +4DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +1DGT)
±(0.5%RDG +2DGT)
BQ TRX
Resistance
0 to 20Ω
0 to 200Ω
0 to 2000Ω
0 to 20.00kΩ
Ω
±(0.2%RDG+2DGT)
25% to 110% FS
±(0.2%RDG+3DGT)
0% to 25% FS
Temp. Drift
Min. Indication
Max. Indication
±150 ppm/°C
- 200
- 328
- 200.0
- 328.0
- 200.0
- 328.0
- 200.0
- 328.0
- 200.0
- 328.0
- 60
- 76
+ 850
+ 1562
+ 200.0
+ 392.0
+ 200.0
+ 392.0
+ 200.0
+ 392.0
+ 200.0
+ 392.0
+ 180
+ 356
±150 ppm/°C
0
0
0
0
20.00 (<)
200.0 (<)
2000 (<)
20.00 (<)
(<) It is possible to modify the decimal point position.
Input impedances and overloads
Module
Inputs
Type
Impedance
Overload (continuous)
Overloads (1s)
BQ LSX/
BQ LSE/
BQ LSF
-200µA to +200µA
-2mA to +2mA
-20mA to +20mA
-200mV to +200mV
-2V to +2V
-20V to +20V
DC/AC
DC/AC
DC/AC
DC/AC
DC/AC
DC/AC
≤2,2kΩ
≤22Ω
≤22Ω
≥2,2kΩ
≥200kΩ
≥200kΩ
5mA
50mA
50mA
10V
50V
50V
10mA
150mA
150mA
20V
100V
100V
BQ HSX
-200mA to +200mA
-2A to +2A
-5A to +5A
-20V to +20V
-200V to +200V
-500V to +500V
DC/AC
DC/AC
DC/AC
DC/AC
DC/AC
DC/AC
≤1Ω
≤0.012Ω
≤0.012Ω
≥2MΩ
≥2MΩ
≥2MΩ
0.8A
7.5A
7.5A
750V
750V
750V
1A
100A
100A
1000V
1000V
1000V
-50°C to +760°C
-58 °F to +1400 °F
-200°C to +1260°C
-328 °F to +2300°F
-200°C to +1000°C
-328°F to +1832°F
-50°C to +1750°C
-58°F to +3182°F
-200°C to +400°C
-328°F to +752°F
J
J
K
K
E
E
S
S
T
T
ILK <0.5µA
Max 5V
Max 10V
BQ TRX
Thermoresistance
-200°C to +850°C
-328°F to +1562°F
-200.0°C to +200,0°C
-328°F to +392°F
-200.0°C to +200,0°C
-328°F to +392°F
-60°C to +180°C
-76°F to +356°F
Pt100
Pt100
Pt250/Pt100
Pt250/Pt100
Pt1000/Pt500
Pt1000/Pt500
Ni100
Ni100
800µA (*)
800µA (*)
90µA (*)
90µA (*)
800µA (*)
800µA (*)
800µA (*)
800µA (*)
Max 5V
Max 10V
BQ TRX
Resistance
0 to 20Ω
0 to 200Ω
0 to 2000Ω
0 to 20.00kΩ
Ω
800µA (*)
90µA (*)
800µA (*)
90µA (*)
Max 5V
Max 10V
BQ TRX
Thermocouple
(*) Maximum measuring current generated for resistance equal to 0
Specifications are subject to change without notice
UDM40DS 040706
3
UDM40
Output specifications
RS422/RS485
Serial output
LED
Connections
Distance
Terminalization
Addresses
Protocol
Data (bidirectional)
Dynamic (reading only)
Static (reading/writing)
Data format
Baud rate
Insulation
(on request)
Module: BR SX
Bidirectional (static and
dynamic variables).
Display of data
reception/transmission
Multidrop, 2 or 4 wires,
1000 m
Directly on the module
by means of jumper
1 to 255, selectable
by means of key-pad
MODBUS RTU/JBUS
Measurement, min value
max value
alarm status
All programming parameters,
min max reset
reset of latch alarm
8 data bit, no parity,
1 stop bit
selectable 4800, 9600,19200
and 38400 bit/s
By means of opto-couplers
4000 V output to
measuring inputs
4000 V output to
power supply input
(on request)
Module: BR SY
Bidirectional (static and
dynamic variables)
3 wires,
max. 15m
1 start bit, 8 data bit,
no parity, 1 stop bit
Selectable 4800, 9600,
19200 and 38400 bit/s
Same as RS422/485
(on request)
Over-range alarm,
up alarm,
down alarm,
down alarm with
start-up deactivation
up alarm with latch,
down alarm with latch
Adjustable from 0 to 100%
of displayed electric range
0 to 100% of displayed range
0 to 255 s
0 to 255 s
Selectable: normally energized
/de-energized
Three available coloures
(green, amber, red)
can be coupled to the alarm
status (traffic-light function).
500 ms, with filter excluded,
without alarm activation delay
1 with module BO R1
(relay output).
Relay output BO R1, R2, R4
Relay output BO R5
Insulation
Open collector output
Insulation
rms
rms
RS232
Serial output
Connections
Distance
Data format
Baud rate
Other features
Alarm outputs
Alarm type
Alarm set-point
Hysteresis
On-time delay
Off-time delay
Output status
Display colour for alarms
Min response time
Output channels
4
Analogue output
Range
Scaling factor
Accuracy
Response time
Termperature drift
Load: 20 mA output
10 V output
Insulation
2, independent with module
BO R2 (2 relay outputs).
4, independent with module
BO R4 (2 relay outputs +
2 open collector outputs).
BO R5 (4 relay outputs)
Type SPDT
AC 1: 8A, 250VAC
DC 12: 5A, 24VDC
AC 15: 2.5A, 250VAC
DC 13: 2.5A, 24VDC
Type SPST (NO)
AC 1: 5A, 250VAC
DC 12: 3A, 24VDC
AC 15: 1,5A, 250VAC
DC 13: 1,5A, 24VDC
4000 VRMS output to
measuring input,
4000 VRMS output to
power supply input.
NPN transistor type
VON 1.2 VDC/ max. 100 mA
VOFF 30 VDC max.
By means of opto-couplers
4000 VRMS output to
measuring input
4000 VRMS output to
power supply input
(on request)
Module: BO AV
0 to 20 mADC, 0 to 10 VDC
Programmable within the
entire retransmission range;
allows to manage the
retransmission of all the
values from
0 to 20 mA / 0 to 10V
± 0.2% FS (@ 25°C ± 5°C)
≤ 10 ms
± 200 ppm/°C
≤ 700 Ω
≥ 10 kΩ
By means of opto-couplers
4000V output to
measuring input
4000V output to
power supply input
The two outputs cannot be
used at the same time.
(on request)
rms
rms
Notes:
Excitation output
BQ LSE Module
Voltage
BQ LSF Module
Voltage
Insulation
13 VDC ±10%
max. 50 mA
25 VDC ±10%
max. 25 mA
25V output to
measuring input
4000 V output to
power supply input
rms
rms
Specifications are subject to change without notice UDM40DS 040706
UDM40
Software functions
Min / Max storage
Password
1st level
2nd level
Measurement selection
Integration time selection
Automatic storage
(in the EEPROM) of the
minimum and maximum
measured value from the
previous memory reset
Numeric code max 4 dgt
2 levels of data protection.
0 to 4999 completly protected.
5000 to 9999 access to
programming is protected .
Alarm set-points are directly
programmable from the
measuring mode.
Depending on the module:
measuring range and type of
probe (resistance, RTD
thermoresistance, TC
thermocouple) or measuring
type (TRMS or DC).
Automatic or from 100.0 to
999.9 ms only in the current
and voltage measurement.
TC
RTD
Digital filter
Filter operating range
Filtering coefficient
Scaling
Linearization
Points
Input range
Scaling factors
Operating mode
Electrical scale compression,
displayed scale
compression/expansion
(max. 2 without filter, up to
10 with filter)
Electrical range
Programmable within the
whole measuring range
Decimal point position
Programmable within the
display range
Displayed range of the variable Programmable within the
display range
Diagnostics
The display flashes when the
limits of the display range
are exceeded and the data
are updated up to 20%
of the rated display range.
Burn-out:
Only temperature inputs
Output range
UdmSoft
Opening of probe’s
connection: EEE indication
Opening of probe’s
connection: EEE indication
probe’s short circuit:
-EEE indication.
0 to 9999
1 to 32
Selection of min value
of the input range.
Selection of max value of
the input range.
Selection of decimal point
position.
Selection of min
display value.
Selection of max display
value.
Up to 16
Selectable by every
single point
Selectable by every
single point
Software for
programming UDM40
by means of PC (Windows 95,
98se, ME, XP) by means of
serial port RS485 and
relevant connection cable.
The software is available in
English, Spanish, Italian,
German, French. See also
“Programming of
UDM40 by means of PC” .
General Specifications
Operating
temperature
Storage
temperature
Insulation reference
voltage
Insulation
Dielectric strength
Rejection
NMRR
CMRR
EMC
0° to 50°C (32° to 122°F)
(H.R. < 90% non-condensing)
-10° to 60°C (14° to 140°F)
(H.R. < 90% non-condensing)
300 VRMS to ground
(500V input)
See table “Insulation between
inputs and outputs”
4000 VRMS for 1 minute
40 dB, 40 to 60 Hz
100 dB, 40 to 60 Hz
Safety Standards
Safety
Connections
Wire section
Housing
Dimensions
Material
Protection degree
Weight
Approvals
EN 61010-1, IEC 61010-1
Screw type
Max 2.5mm2
1/8 DIN, 48 x 96 x 105 mm
PC-ABS,
self-extinguishing: UL 94 V-0
Front: IP67, NEMA4x
Connections: IP20
520 g approx (included all
modules and packing)
CE, UR, CSA
EN61000-6-2, IEC61000-6-2
EN61000-6-3, IEC61000-6-3
Specifications are subject to change without notice
UDM40DS 040706
5
UDM40
Supply Specifications
AC/DC voltage
90 to 260V (standard)
18 to 60V (on request)
Excitation output
Insulation between inputs and outputs
Meas.
inputs
Relay Static Analogue Serial
AUX
90-260VAC/
output output output
Port p.supply DC p. supply
18-60VAC/
DC p.supply
Meas.
inputs
-
4kV
4kV
4kV
4kV
25V
4kV
4kV
Relay
Output
4kV
-
2kV
4kV
4kV
4kV
4kV
4kV
Static
Output
4kV
2kV
-
4kV
4kV
4kV
4kV
4kV
Analogue
Output
4kV
4kV
4kV
-
4kV
4kV
4kV
4kV
10
Serial
Port
4kV
4kV
4kV
4kV
-
4kV
4kV
4kV
5
AUX
p.supply
25V
4kV
4kV
4kV
4kV
-
4kV
4kV
90-260VAC/
DC p..supply
4kV
4kV
4kV
4kV
4kV
4kV
-
-
18-60VAC/
DC p. supply
4kV
4kV
4kV
4kV
4kV
4kV
-
-
V
max. 30 s.
Continuous
30
25
BQ
LS
F
20
15
BQ LSE
0
10
20
30
40
50
60
mA
Available modules
Type
UDM40 main unit
DC/AC input: 200µA , 2mA, 20mA,
200mA, 2V, 20V
DC/AC input: 200µA , 2mA, 20mA,
200mA, 2V, 20V + excitation output
DC/AC input: 200mA, 2A, 5A,
20V, 200V, 500V
Input: 20Ω, 200Ω, 2kΩ, 20kΩ
TC: J-K-S-T-E, Pt100-250-500-1000
Analogue output 0 to 20mA, 0 to 10VDC
Relay output
Relay output
Outputs: 2 relays + 2 open collectors
Possible module combinations
N. of
channels
Ordering
code
BD 40
1
BQ LSX
1
BQ LSE/
BQ LSF
1
BQ HSX
1
1
1
1
2
4
BQ TRX
BQ TRX
BO AV
BO R1
BO R2
BO R4
Relay output
4
BO R5
RS485 Serial Port
1
BR SX
RS232 Serial Port
1
BR SY
Power supply 18 to 60V AC/DC
Power supply 90 to 260V AC/DC
6
≤ 30VA/12W (90 to 260V)
≤ 20VA/12W (18 to 60V)
Energy consumption
BP L
BP H
Basic Unit
Slot A Slot B Slot C Slot D
Measuring inputs:
LSX, LSE, LSF, HSX, TRX
RS485 Serial port: SX
RS232 Serial port: SY
Analogue output: AV (*)
Relay outputs and/or open
collector: R1, R2, R4, R5
Power supply: H, L
(*) Up to 1 module max.
Used calculation formulas
Only for TRMS Measurements
Instantaneous effective
voltage (TRMS)
Instantaneous effective
current (TRMS)
V1 =
A1 =
1
×
n
n
å
( V 1 ) i2
1
n
1
× å ( A 1 ) i2
n
1
Specifications are subject to change without notice UDM40DS 040706
UDM40
Wiring diagrams
Process signal wiring diagrams
BQ LSE/LSF
-
Voltage measurements
3-wire connection to probe
BQ LSE/LSF
Fig. 5
Probe Signal output
+
+ Vdc
Probe power supply
Probe
Fig. 4
+
+ Vdc
-
Current measurements
4-wire connection to probe
-
Voltage measurements
4-wire connection to probe
˜
BQ LSE/LSF
Fig. 6
Probe Signal output
BQ LSE/LSF
+
Probe power supply
˜
Probe
˜
Voltage measurements
+
Probe
˜
Current measurements
+
+ Vdc
Probe Signal output
Fig. 3
Probe power supply
Fig. 2
+
+ Vdc
-
Current measurements
3-wire connection to probe
Probe Signal output
BQ LSX/LSE/LSF
Probe
Fig. 1
Probe power supply
BQ LSX/LSE/LSF
Wirings for high-level signals
BQ LSE/LSF
Current measurements
2-wire connection to probe
BQ HSX
Fig. 8
BQ HSX
Fig. 9
Probe Signal output
+
+ Vdc
Probe power supply
Probe
Fig. 7
+
Current measurements ˜
Specifications are subject to change without notice
UDM40DS 040706
˜
+
Voltage measurements˜
˜
7
UDM40
Wiring diagrams (cont.)
Wiring diagrams for temperature measurements
BQ TRX
Fig. 10
BQ TRX
Fig. 11
Temp. measur. from thermoresistance
Temp. measur. from thermocouple
BQ TRX
Fig. 12
Resistance measurements
Wiring diagrams for power supply
BP H: power supply
BP L: power supply
F1= 630mA T
250V 5x20mm
F1= 3.15A T
250V 5x20mm
Wiring diagrams of optional modules
BO AV: analogue output
(10V, 20mA DC)
8
BO R1: 1 relay output
BO R2: 2 relay outputs
BO R5: 4 relay outputs
Specifications are subject to change without notice UDM40DS 040706
UDM40
Wiring diagrams of optional modules (cont.)
BO SY: RS232 direct
connection to PC by
means of COM port.
RS232 has no terminalization.
GND
Vcc
RX
TX
TX
RX
SY
LED
3
2
5
1
3
2
5
9
1
6
BO R4: dual relay output + dual open collector output: the load resistances (Rc) must be designed so that the close
contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC.
VDC: power supply output
Vo+: positive output (open collector transistor).
GND: ground collector (open collector transistor).
RS1,2,3...N
NON terminalized network
Terminalized network
BR SX: RS485 4-wire connection: additional devices provided with RS485 port (indicated as RS1,2,3...N) are connected
in parallel. The termination of the serial port is carried out only on the last instrument of the network. The serial module is
provided with a jumper for the termination of the RS485 network as shown in the figure above.
Note: particular types of cables or plants may require an external termination. For the network connections use twisted
cable type AWG26.
Programming UDM40 by means of PC
To UDM
1
1m
UDM40 is programmable by PC by means of the UdmSoft software (available on
request). The user can program all parameters of UDM40 that will be subsequently uploaded and set in the instrument by the RS485 network (BR SX).
Should UDM40 be without the RS485 serial module, all programming parameters
will be uploaded and set in the instrument by the RS232 auxiliary serial connection (1) located on the side of the measuring input module using the special connection cable (2) available on request, as shown in the figures on the left. It is
also possible to program the instrument using the dot connector (1) by means of
the HyperTerminal Windows functions of a PC.
2
Note: the RS232 auxiliary port IS NOT insulated from the measuring inputs.
Ordering code of the cable (2): UCOM1
To PC
Specifications are subject to change without notice
UDM40DS 040706
9
UDM40
Front panel description
:
- to program values;
- to select functions;
- to scroll display pages.
: for special functions.
2. Display
Instantaneous measurements:
- 4 digit (max display 9999).
Alphanumeric indications by means of LED display for:
- Display of configuration parameters;
- The measured variable.
4
2
3
1
1. Key-pad
The programming of the configuration parameters and the
display may be easily controlled by means of the 4 function
keys.
: to enter the programming phase and to confirm the
password.
Dimensions
3. Alarm status LED
Display any alarm condition
4. Engineering unit
The instrument is supplied with a complete set of
self-sticking labels with the main engineering units.
Engineering Units
11mm
105mm
48mm
96mm
45mm -0,3/+0,6
92mm -0,3/+0,8
Panel depth: 8mm.
10
Specifications are subject to change without notice UDM40DS 040706
UDM40
Modules
Input modules
Output modules
Scale 1:1
BQ LSX, BQ LSE, BQ
LSF, BQ HSX, BQ TRX
Measuring inputs
BO AV
Single analogue
output 10V, 20mA DC
Output modules
BO R1
Single relay output
BO R2
Dual relay output
BO R4
Dual relay output +
Dual open collector
Serial port modules
BR SX
RS485 Serial port
BO R5
4 relay outputs
Power supply modules
BR SY
RS232 Serial port
Specifications are subject to change without notice
UDM40DS 040706
BP H
Power supply:
60 to 260V AC/DC
BP L
Power supply:
18 to 60V AC/DC
11