® ® INNOVATION and EXCELLENCE Single Output UEP Models High-Density, 2" x 1" 1-4.5 Amp, 11-18 Watt DC/DC's Features Models Include 3.3V @ 4.5A 5V @ 3.5A 12V @ 1.2A 15V @ 1A Choice of 3 input ranges: 10-18V, 18-36V, 36-75V Guaranteed efficiencies to 86% 11-18 Watts in 1" x 2" package 340kHz synchronous-rectifier topologies –40 to +60/70°C ambient w/o derating Fully isolated (1500Vdc); I/O protected Trim and On/Off Control UL60950/EN60950 certified CE mark (75VIN models) The UEP 11-18Watt series DC/DC converter is an alternative pinout for DATEL’s flagship A-Series. An external pinout configuration affords the design layout to be oriented for optimal thermal performance thereby increasing available output power as much as 20%. Available in a 1" x 2" package, these converters can deliver up to 18 Watts at the same ambient temperatures as their 15 Watt counterparts. By combining a high-frequency (340kHz), high-efficiency (to 88%), synchronousrectifier topology with the newest components and time-tested, fully automated, SMT-on-pcb construction, these UEP Models are able to bring you 11-18W in the standard 2" x 1" package from which most competitors can only get 5-10W. All UEP’s deliver their full output power over ambient temperature ranges from –40°C to as high as +70°C (model and input voltage dependent) without heat sinks or supplemental forced-air cooling. Devices derate to +100°C. Output voltages are 3.3, 5, 12 or 15 Volts. Input voltage ranges are 10-18V ("D12" models), 18-36V ("D24" models) or 36-75V ("D48") models. All models feature input pi filters, input undervoltage and overvoltage lockout, input reverse-polarity protection, output overvoltage protection, output current limiting, and continuous short-circuit protection. Standard features also include On/Off Control and outputtrim. All models are certified to IEC950, UL60950 and EN60950 safety requirements for OPERATIONAL insulation. "D48" models (36-75V inputs) are CE marked. UEP 11-18W DC/DC’s are packaged in low-cost, light-weight, diallyl phthalate (UL94V-0 rated) plastic packages with standoffs. EMC compliance is achieved via a low-noise design rather than through expensive metal shielding. +INPUT +OUTPUT SWITCH CONTROL ➀ –OUTPUT ➀ –INPUT PWM CONTROLLER OPTO ISOLATION REFERENCE & ERROR AMP TRIM UVLO & OVLO COMPARATORS ON/OFF CONTROL ➀ 1.5, 1.8, 2.5, 3.3V and 5V-output models use the synchronous-rectifier configuration shown above. 12V and 15V-output models employ a standard, diode-rectification architecture. Figure 1. Simplified Schematic DATEL, Inc., Mansfield, MA 02048 (USA) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email: [email protected] · Internet: www.datel.com UEP Series 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Performance Specifications and Ordering Guide ➀ Input Output R/N (mVp-p) ➁ Regulation (Max.) Range (Volts) IIN ➃ (mA) Package (Case, Pinout) Efficiency VOUT (Volts) IOUT (mA) Typ. Max. Line Load ➂ VIN Nom. (Volts) Min. Typ. UEP-3.3/4500-D12 3.3 4500 85 100 ±0.2% ±0.5% 12 10-18 80/1490 84.5% 83.5% C15, P21 UEP-3.3/4500-D24 3.3 4500 85 100 ±0.2% ±0.5% 24 18-36 50/730 87.5% 85.5% C15, P21 UEP-3.3/4500-D48 Model 3.3 4500 85 100 ±0.2% ±0.5% 48 36-75 35/360 87.5% 85.5% C15, P21 UEP-5/3500-D12 5 3500 85 100 ±0.2% ±0.5% 12 10-18 120/1760 86% 84% C15, P21 UEP-5/3500-D24 5 3500 85 100 ±0.2% ±0.5% 24 18-36 65/850 88% 86% C15, P21 UEP-5/3500-D48 5 3500 85 100 ±0.2% ±0.5% 48 36-75 40/430 88% 86% C15, P21 UEP-12/1400-D12 12 1400 85 100 ±0.2% ±0.5% 12 10-18 60/1650 85% 82.5% C15, P21 UEP-12/1400-D24 12 1400 85 100 ±0.2% ±0.5% 24 18-36 45/800 87% 85% C15, P21 C15, P21 UEP-12/1400-D48 12 1400 85 100 ±0.2% ±0.5% 48 36-75 20/400 87% 85% UEP-15/1200-D12 15 1200 85 100 ±0.2% ±0.5% 12 10-18 60/1760 85% 82.% C15, P21 UEP-15/1200-D24 15 1200 85 100 ±0.2% ±0.5% 24 18-36 45/860 87% 85% C15, P21 UEP-15/1200-D48 15 1200 85 100 ±0.2% ±0.5% 48 36-75 30/430 87% 85% C15, P21 ➀ Typical at TA = +25°C under nominal line voltage and full-load conditions, unless otherwise noted. ➁ Ripple/Noise (R/N) is tested/speciifed over a 20MHz bandwidth. All models are specified with no external input/output capacitors. P A R T N U M B E R ➂ Load regulation is specified over 10%-100% load conditions. ➃ Nominal line voltage, no-load/full-load conditions. M E C H A N I C A L S T R U C T U R E S P E C I F I C A T I O N S 2.00 (50.80) U EP - 3.3 / 4500 - D48 N Output Configuration: U = Unipolar Maximum Output Current in mA Case C15 N Suffix Available for 12VOUT and 15VOUT Models Wide Range Input Nominal Output Voltage: 3.3, 5, 12 or 15 Volts PLASTIC CASE 0.49 (12.45) STANDOFF 0.020 (0.51) 0.040 ±0.002 DIA. (1.016 ±0.051) 0.20 MIN (5.08) 1.800 (45.72) Input Voltage Range: D12 = 10-18 Volts (12V nominal) D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) 1 4 2 1.00 (25.40) Optional Functions 0.400 (10.16) 0.10 (2.54) 5 0.600 (15.24) 3 6 UEP converters are designed such that the 12 and 15VOUT models can be configures for either positive logic on/off control (no suffix) or negative logic ("N" suffix). 3.3 and 5VOUT models are available with positive logic only (no suffix). 0.100 (2.54) BOTTOM VIEW DIMENSIONS ARE IN INCHES (MM) No Suffix On/Off Control function (positive polarity) on pin 3 I/O Connections Pin Function P21 1 +Input 2 Input Return 3 On/Off Control 4 +Output 5 Output Return 6 Trim N On/Off Control function (negative polarity) on pin 3. (12V and 15V models only. 2 0.400 (10.16) 0.10 (2.54) 0.800 (20.32) UEP Models 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Performance/Functional Specifications Environmental Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀➁ Operating Temperature (Ambient): Without Derating ➅ With Derating Input –40 to +60/70°C to +100°C (See Derating Curves) Input Voltage Range: D12A Models D24A Models D48A Models 10-18 Volts (12V nominal) 18-36 Volts (24V nominal) 36-75 Volts (48V nominal) Case Temperature: Maximum Allowable +100°C Storage Temperature –40 to +105°C Overvoltage Shutdown: D12A Models D24A Models D48A Models 18.5-21 Volts (20V typical) 37-40 Volts (38V typical) 77-81 Volts (78.5V typical) Dimensions Physical Start-Up Threshold: ➂ D12A Models D24A Models D48A Models 9.3-9.8 Volts (9.6V typical) 16.5-18 Volts (17V typical) 34-36 Volts (35V typical) Undervoltage Shutdown: ➂ D12A Models D24A Models D48A Models 7-8.5 Volts (8V typical) 15.5-17.5 Volts (16.5V typical) 32.5-35.5 Volts (34.5V typical) Input Current: Normal Operating Conditions Standby Mode (Off, OV, UV) See Ordering Guide 5mA Input Filter Type Pi Reverse-Polarity Protection Brief duration, 10A maximum On/Off Control (Optional, Pin 3): ➃ D12, D24, & D48 Models D12N, D24N, & D48N Models 2" x 1" x 0.49" (51 x 25 x 12.45mm) Shielding None Case Material Diallyl phthalate, meets EN60950 flamability requirements Pin Material Brass, solder coated Weight 1.4 ounces (39.7 grams) ➀ ➁ ➂ ➃ All models are specified with no external input/output capacitors. See Minimum Output Loading Requirements under Technical Notes. See Technical Notes for details. The On/Off Control is designed to be driven with open-collector logic or the application of appropriate voltages (referenced to –Input (Pin 2)). Applying a voltage to the On/Off Control pin when no input voltage is applied to the converter may cause permanent damage. See Technical Notes. ➄ Output noise may be further reduced with the addition of external output capacitors. See Technical Notes. ➅ Operating temperature range without derating is model and input-voltage dependent. See Temperature Derating. On = open or 13V - +VIN, IIN = 50µA max. Off = 0-0.8V, IIN = 1mA max. On = 0-0.5V, IIN = 50µA max. Off = open or 2.4-10V, IIN = 3.7mA max. Absolute Maximum Ratings Input Voltage: Continuous: D12 Models D24 Models D48 Models Transient (100msec): D12 Models D24 Models D48 Models Output VOUT Accuracy (50% load): ±1.5%, maximum Minimum Loading: ➁ 3.3V/5V Outputs 12V/15V Outputs No load 25mA Ripple/Noise (20MHz BW) ➀ ➄ See Ordering Guide Line/Load Regulation See Ordering Guide Efficiency See Ordering Guide Isolation Voltage: Input-to-Output 1500Vdc minimum Isolation Capacitance 470pF Output Overvoltage Protection: 3.3V Outputs 5V/12V/15V Outputs Isolation Resistance 100MΩ Output Current Current Limit Inception: 3.3V Models 5V Models 12V Models 15V Models 5.5-7 Amps 5.5-6 Amps 1.9-2.7 Amps 1.5-2.1 Amps Short Circuit: ➂ Average Current Hiccup, indefinite 3 Amps maximum VOUT Trim Range ±5% Overvoltage Protection Zener/transorb clamp, magnetic feedback Temperature Coefficient Input Reverse-Polarity Protection ±0.04% per °C. 200µsec max. to ±1.5% of final value Start-Up Time: ➂ VIN to VOUT On/Off to VOUT 50msec 30msec Switching Frequency 340kHz (±40kHz) 50 Volts 50 Volts 100 Volts Current must be <10 Amps. Brief duration only. Fusing recommended. 4.5 Volts, unlimited duration 6.8/15/18 Volts, unlimited duration Hiccup. Devices can withstand sustained output short circuits without damage. Case Temperature +100°C Storage Temperature –40 to +105°C Lead Temperature (soldering, 10 sec.) +300°C These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied. Dynamic Characteristics Transient Response (50-100% load) 22 Volts 44 Volts 88 Volts 3 UEP Series T E C H N I C A L 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Trim adjustment greater than 5% can have an adverse effect on the converter's performance and is not recommended. N O T E S Floating Outputs 4 1 Since these are isolated DC/DC converters, their outputs are "floating." Designers will usually use the –Output (pin 5) as the ground/return of the load circuit. You can, however, use the +Output (pin 4) as ground/return to effectively reverse the output polarity. +OUTPUT +INPUT 2 –INPUT Minimum Output Loading Requirements 3 3.3 and 5V models employ a synchronous-rectifier design topology. All models regulate within spec and are stable under no-load conditions. 12/15V models employ a traditional forward, diode-rectification architecture and require 25mA loading to achieve their listed regulation specs. Operation under 25mA load conditions will not damage the 12/15V devices; however they may not meet all listed specifications. ON/OFF CONTROL TRIM –OUTPUT 6 20kΩ 5-22 Turns LOAD 5 Figure 2. Trim Connections Using A Trim Pot 1 +INPUT +OUTPUT 4 RTRIM DOWN Filtering and Noise Reduction 2 –INPUT All UEP Series DC/DC Converters achieve their rated ripple and noise specifications with no external input/output capacitors. In critical applications, input/output noise may be further reduced by installing external I/O caps. Input capacitors should be selected for bulk capacitance, low ESR and high rms-ripple-current ratings. Output capacitors should be selected for low ESR and appropriate frequency response. All caps should have appropriate voltage ratings and be mounted as close to the converters as possible. 3 ON/OFF CONTROL 6 TRIM LOAD 5 –OUTPUT Figure 3. Trim Connections To Decrease Output Voltage Using Fixed Resistors 1 The most effective combination of external I/O capacitors will be a function of your particular load and layout conditions. Our Applications Engineers recommend potential solutions and can discuss the possibility of our modifying a given device’s internal filtering to meet your specific requirements. Contact our Applications Engineering Group for additional details. +INPUT +OUTPUT 4 2 –INPUT 3 Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exists. For DATEL UER 11-18 Watt DC/DC Converters, you should use slow-blow type fuses with values no greater than the following. ON/OFF CONTROL 6 TRIM LOAD RTRIM UP –OUTPUT 5 Figure 4. Trim Connections To Increase Output Voltage Using Fixed Resistors Model Trim Equation UEP-3.3/4500-D12 UEP-3.3/4500-D24 UEP-3.3/4500-D48 RTDOWN (kΩ) = UEP-5/3500-D12 UEP-5/3500-D24 UEP-5/3500-D48 RTDOWN (kΩ) = These converters have a trim capability (pin 6) that allows users to adjust the output voltage ±5%. Adjustments to the output voltage can be accomplished via a trim pot, Figure 2, or a single fixed resistor as shown in Figures 3 and 4. A single fixed resistor can increase or decrease the output voltage depending on its connection. Fixed resistors should have an absolute TCR less than 100ppm/°C to minimize sensitivity to changes in temperature. UEP-12/1400-D12 UEP-12/1400-D24 UEP-12/1400-D48 RTDOWN (kΩ) = A single resistor connected from the Trim (pin 6) to the +Output (pin 4), see Figure 3, will decrease the output voltage. A resistor connected from the Trim (pin 6) to –Output (pin 5) will increase the output voltage. UEP-15/1200-D12 UEP-15/1200-D24 UEP-15/1200-D48 RTDOWN (kΩ) = VIN Range D12 Models D24 Models D48 Models Fuse Value 3 Amps 2 Amps 1 Amp Trimming Output Voltages RTUP (kΩ) = RTUP (kΩ) = RT UP (kΩ) = RTUP (kΩ) = 2.49(VO – 1.27) 3.3 – VO 3.16 VO – 3.3 –16.9 –16.9 2.49(VO – 2.527) –15 5 – VO 6.292 VO – 5 –15 6.34(VO – 5.714) –49.9 12 – VO 36.23 VO – 12 –49.9 7.87(VO – 7.136) –63.4 15 – VO 56.16 VO – 15 –63.4 Accuracy of adjustment is subject to tolerances or resistor values and factory-adjusted output accuracy. VO = desired output voltage. 4 UEP Models 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Start-Up Threshold and Undervoltage Shutdown Sync Function (Optional) Under normal start-up conditions, UEP DC/DC Converters will not begin to regulate properly until the ramping input voltage exceeds the Start-Up Threshold. Once operating, devices will turn off when the applied voltage drops below the Undervoltage Shutdown point. Devices will remain off as long as the undervoltage condition continues. Units will automatically re-start when the applied voltage is brought back above the Start-Up Threshold. The hysteresis built into this function avoids an indeterminate on/off condition at a single input voltage. See Performance/Functional Specifications table for actual limits. Contact DATEL for further information. Start-Up Time The VIN to VOUT start-up time is the interval of time where the input voltage crosses the turn-on threshold point, and the fully loaded output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input/output capacitance, and load. The UHE Series implements a soft start circuit that limits the duty cycle of the PWM controller at power up, thereby limiting the Input Inrush current. On/Off Control The On/Off Control to VOUT start-up time assumes the converter has its nominal input voltage applied but is turned off via the On/Off Control pin. The specification defines the interval between the time at which the converter is turned on and the fully loaded output voltage enters and remains within its specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off Control to VOUT start-up time is also governed by the internal soft start circuitry and external load capacitance. The input-side, remote On/Off Control function (pin 4) can be ordered to operate with either polarity (12 and 15 Volt models only). Positive-polarity devices (standard, no part-number suffix) are enabled when pin 3 is left open or is pulled high (+13V to VIN applied with respect to –Input, pin 2, (see Figure 2). Positive-polarity devices are disabled when pin 5 is pulled low (0-0.8V with respect to –Input). Negative-polarity devices are off when pin 3 is open or pulled high (+2.4V to +10V), and on when pin 3 is pulled low (0-0.5V). See Figure 3. 1 Input Overvoltage/Undervoltage Shutdown and Start-Up Threshold Under normal start-up conditions, devices will not begin to regulate until the ramping-up input voltage exceeds the Start-Up Threshold Voltage (35V for "D48" models). Once operating, devices will not turn off until the input voltage drops below the Undervoltage Shutdown limit (34V for "D48" models). Subsequent re-start will not occur until the input is brought back up to the Start-Up Threshold. This built in hysteresis prevents any unstable on/off situations from occurring at a single input voltage. +INPUT 200k 13V CIRCUIT 3 ON/OFF CONTROL 2 5V CIRCUIT Input voltages exceeding the input overvoltage shutdown specification listed in the Performance/Functional Specifications will cause the device to shutdown. A built-in hysteresis of 0.6 to 1.6 Volts for all models will not allow the converter to restart until the input voltage is sufficiently reduced. –INPUT Figure 2. Driving the Positive Polarity On/Off Control Pin Input Reverse-Polarity Protection 1 If the input-voltage polarity is accidentally reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If the source is not current limited (<10A) nor the circuit appropriately fused, it could cause permanent damage to the converter. +INPUT 3 ON/OFF CONTROL 2 Current Limiting When output increases to 120% to 190% of the rated output current, the DC/DC converter will go into a current limiting mode. In this condition the output voltage will decrease proportionately with increases in output current, thereby maintaining a somewhat constant power dissipation. This is commonly referred to as power limiting. Current limit inception is defined as the point where the full-power output voltage falls below the specified tolerance. See Performance/Functional Specifications. If the load current being drawn from the converter is significant enough, the unit will go into a short circuit condition. See "Short Circuit Condition." –INPUT Figure 3. Driving the Negative Polarity On/Off Control Pin Dynamic control of the remote on/off function is best accomplished with a mechanical relay or an open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current (see Performance Specs) when activated and withstand appropriate voltage when deactivated. Applying an external voltage to pin 3 when no input power is applied to the converter can cause permanent damage to the converter. 5 UEP Series 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Short Circuit Condition Temperature Derating Curves for 5V Output Models 20 When a converter is in current limit mode the output voltages will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. VIN = 18V-27V (D24) 17.5 VIN = 36V-48V (D48) 15 Output Power (Watts) Following a time-out period, the PWM will restart, causing the output voltage to begin ramping to its appropriate value. If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UEP is capable of enduring an indefinite short circuit output condition. 12.5 VIN = 18V-30V (D24) 10 VIN = 36V-60V (D48) 7.5 VIN = 12V (D12) VIN = 18V-36V (D24) 5 VIN = 36V-75V (D48) Thermal Shutdown 2.5 These UEP converters are equipped with Thermal Shutdown Circuitry. If environmental conditions cause the internal temperature of the DC/DC converter rises above the designed operating temperature, a precision temperature sensor will power down the unit. When the internal temperature decreases below the threshold of the temperature sensor the unit will self start. See Performance/Functional Specifications. 0 –40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 Ambient Temperature (˚C) Temperature Derating Curves for 12V Output Models Output Overvoltage Protection 18 UEP output voltages are monitored for an overvoltage condition via a comparator which is optically coupled to the primary side. If the output voltage should rise to a level which could be damaging to the load circuitry, the sensing circuitry will power down the PWM controller causing the output voltages to decrease. Following a time-out period the PWM will restart, causing the output voltages to ramp to their appropriate values. If the fault condition persists, and the output voltages again climb to excessive levels, the overvoltage circuitry will initiate another shutdown cycle. This on/off cycling is referred to as "hiccup" mode. 16 VIN = 18V-27V (D24) VIN = 36V-48V (D48) Output Power (Watts) 14 12 VIN = 18V-30V (D24) 10 VIN = 36V-60V (D48) 8 VIN = 12V (D12) 6 VIN = 18V-36V (D24) VIN = 36V-75V (D48) 4 2 0 –40 0 40 45 50 TEMPERATURE DERATING 55 60 65 70 75 80 85 90 95 100 Ambient Temperature (˚C) Temperature Derating Curves for 3.3V Output Models Temperature Derating Curves for 15V Output Models 17.5 20 VIN = 18V-27V (D24) 18 VIN = 18V-27V (D24) VIN = 36V-48V (D48) 15 VIN = 36V-48V (D48) 16 14 Output Power (Watts) Output Power (Watts) 12.5 10 VIN = 18V-30V (D24) VIN = 36V-60V (D48) 7.5 VIN = 12V (D12) VIN = 18V-36V (D24) 5 VIN = 18V-30V (D24) 12 VIN = 36V-60V (D48) 10 8 VIN = 12V (D12) 6 VIN = 18V-36V (D24) VIN = 36V-75V (D48) VIN = 36V-75V (D48) 4 2.5 2 0 0 –40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 –40 Ambient Temperature (˚C) 0 40 45 50 55 60 65 70 75 Ambient Temperature (˚C) 6 80 85 90 95 100 UEP Models 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S EFFICIENCY VS. LINE AND LOAD UEP-5/3500-D12 Efficiency vs. Line Voltage and Load Current 90 85 85 80 80 75 75 Efficiency (%) Efficiency (%) UEP-3.3/4500-D12 Efficiency vs. Line Voltage and Load Current 90 70 65 60 VIN = 10V 55 VIN = 12V 70 65 60 VIN = 10V 55 VIN = 12V VIN = 18V VIN = 18V 50 50 45 45 40 0.4 0.91 1.43 1.94 2.45 2.96 3.48 3.99 40 0.3 4.5 0.7 1.1 Load Current (Amps) 85 85 80 80 75 75 70 65 VIN = 18V 55 VIN = 24V 60 VIN = 18V 55 VIN = 24V 45 45 1.94 2.45 2.96 3.48 3.99 40 0.3 4.5 0.7 1.1 Load Current (Amps) 85 85 80 80 75 75 70 65 55 VIN = 48V 1.5 60 VIN = 36V 55 VIN = 48V 45 45 1.94 2.45 2.96 3.1 3.5 VIN = 75V 50 1.43 2.7 65 50 0.91 2.3 70 VIN = 75V 40 0.4 1.9 UEP-5/3500-D48 Efficiency vs. Line Voltage and Load Current 90 Efficiency (%) Efficiency (%) UEP-3.3/4500-D48 Efficiency vs. Line Voltage and Load Current VIN = 36V 3.5 Load Current (Amps) 90 60 3.1 VIN = 36V 50 1.43 2.7 65 50 0.91 2.3 70 VIN = 36V 40 0.4 1.9 UEP-5/3500-D24 Efficiency vs. Line Voltage and Load Current 90 Efficiency (%) Efficiency (%) UEP-3.3/4500-D24 Efficiency vs. Line Voltage and Load Current 90 60 1.5 Load Current (Amps) 3.48 3.99 40 0.3 4.5 Load Current (Amps) 0.7 1.1 1.5 1.9 2.3 Load Current (Amps) 7 2.7 3.1 3.5 UEP Series 1 1 - 1 8 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S EFFICIENCY VS. LINE AND LOAD UEP-15/1200-D12 Efficiency vs. Line Voltage and Load Current 90 85 85 80 80 Efficiency (%) Efficiency (%) UEP-12/1400-D12 Efficiency vs. Line Voltage and Load Current 90 75 70 VIN = 10V VIN = 12V 65 75 70 VIN = 10V VIN = 12V 65 VIN = 18V VIN = 18V 60 60 55 0.10 0.26 0.43 0.59 0.75 0.91 1.06 1.24 55 0.10 1.40 0.24 0.38 Load Current (Amps) 85 85 80 80 75 VIN = 18V VIN = 24V 65 0.79 0.93 1.06 1.2 75 70 VIN = 18V VIN = 24V 65 VIN = 36V VIN = 36V 60 60 55 0.10 0.26 0.43 0.59 0.75 0.91 1.06 1.24 55 0.10 1.40 0.24 0.38 Load Current (Amps) 0.65 0.79 0.93 1.06 1.2 UEP-15/1200-D48 Efficiency vs. Line Voltage and Load Current 90 90 85 85 80 80 Efficiency (%) 75 70 65 VIN = 36V 60 VIN = 48V 55 VIN = 75V 75 70 VIN = 36V 65 VIN = 48V 60 VIN = 75V 55 50 45 0.10 0.51 Load Current (Amps) UEP-12/1400-D48 Efficiency vs. Line Voltage and Load Current Efficiency (%) 0.65 UEP-15/1200-D24 Efficiency vs. Line Voltage and Load Current 90 Efficiency (%) Efficiency (%) UEP-12/1400-D24 Efficiency vs. Line Voltage and Load Current 90 70 0.51 Load Current (Amps) 0.26 0.43 0.59 0.75 0.91 1.06 1.24 50 0.10 1.40 0.24 0.38 0.51 0.65 0.79 Load Current (Amps) Load Current (Amps) 8 0.93 1.06 1.2 A Series 9 - 1 5 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S Typical Performance Curves Output Ripple and Noise (PARD) Output Ripple and Noise (PARD) (VIN = nominal, 3.3V @ 4.5A, no external capacitors.) (VIN = nominal, 12V @ 1.4A, no external capacitors.) 20mV/div, 20MHz BW Output Ripple and Noise (PARD) Output Ripple and Noise (PARD) (VIN = nominal, 5V @ 3.5A, no external capacitors.) (VIN = nominal, 15V @ 1.2A, no external capacitors.) 20mV/div, 20MHz BW ® 20mV/div, 20MHz BW ® INNOVATION and EXCELLENCE ISO-9001 REGISTERED DS-0502 9/01 DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH München, Germany Tel: 89-544334-0 DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025 DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: [email protected] Data Sheet Fax Back: (508) 261-2857 DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark. 9