XPPOWER VCP24US15

ACDC
24 Watts
VCP Series
xppower.com
•
Low Cost
•
Output Voltages from 5 to 24 V
•
PCB Mount
•
Open Frame & Encapsulated Versions
•
IT & Medical Approvals
•
Class II Construction
•
No Load Input Power <0.3 W
B R A N D
Specification
Input
General
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
0.6 A max at 90 VAC
40 A max at 240 VAC, cold start at 25 °C
EN61000-3-2, class A
<0.3 W
Internal T2.0A/250 V fuse in line
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
See table
±2% at 50% load
No minimum load required
2 s max
50 ms typical
5 ms typical at full load and 115 VAC
±0.5% max
2% max, 0-100% load
10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
See table
See table
120-280 %, auto recovery
Trip and restart (hiccup mode)
0.2 %/°C
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Output
Efficiency
Isolation
Switching Frequency
MTBF
•
•
•
•
See table
4000 VAC Input to Output
65 kHz typical
250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature • -20 °C to +80 °C
Vibration
• 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
•
•
•
•
Radiated Immunity
EFT/Burst
Surge
•
•
•
Conducted Immunity
Magnetic Field
Dips & Interruptions
•
•
•
Safety Approvals
•
EN55011/22, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, ±4kV indirect contact,
±8kV air, Perf Criteria A
EN61000-4-3, 3 V/m, Perf Criteria A
EN61000-4-4, level 2, Perf Criteria A
EN61000-4-5, installation class 3,
Perf Criteria A
EN61000-4-6, 3 V, Perf Criteria A
EN61000-4-8, 1 A/m, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
Output Power
Output Voltage(2)
Output Current
Ripple & Noise(1)
OVP Setting(3)
Efficiency(5)
Model Number(4)
12.5 W
5.0 V
2.5 A
100 mV
10.0 V
73%
VCP24US05†^
24.0 W
12.0 V
2.0 A
100 mV
20.0 V
80%
VCP24US12†^
24.0 W
15.0 V
1.6 A
150 mV
25.0 V
81%
VCP24US15†^
24.0 W
24.0 V
1.0 A
200 mV
35.0 V
82%
VCP24US24†^
Notes
1. Measured at DC output connectors using 20 MHz bandwidth and 0.1 µF ceramic capacitor in parallel with 10 µF electrolytic capacitor placed at connector terminals.
2. Other voltages between 5.0 V and 24.0 V are available, consult sales for details.
3. Typical trip point.
4. For encapsulated versions, add suffix ‘-E’ to the model number, e.g. VCP24US12-E
5. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input.
† Available from Farnell & element14. See page 28.
^ Available from Newark. See page 28.
Mechanical Details
Open Frame Version
Encapsulated Version (E)
2.91 (73.8)
1.45 (36.9)
0.72
(18.5)
1.39 (35.3)
2
1
1.64 (41.6)
0.72
(18.5)
2
1.04 (26.5)
0.80 (20.2)
TOP VIEW
0.71
(18.0)
0.68 (17.4)
TOP VIEW
4
3
0.71 (18.0)
4
1.16 (29.5)
1.30 (33.1)
1
1.04 (26.5)
3
1.81 (46.0)
0.80 (20.2)
0.68 (17.4)
1.39 (35.3)
1.16 (29.5)
1.30 (33.1)
0.14 (3.8)
0.76 (19.4)
1.12 (28.5)
0.18 (4.50)
ø 0.07
(ø1.8)
ø 0.04
(ø1.0)
0.15 (3.8)
0.06 (1.6)
1.15 (29.3)
3.11 (79.0)
Pin
ø 0.04
(ø1.0)
Designation
1
Live
2
Neutral
3
Output +VE
4
Output -VE
Notes
1. All dimensions are in inches (mm).
2. Weight: open frame versions: 0.165 lbs (75 g) approx, encapsulated versions 0.32 lbs (150 g) approx.
3. Tolerance: x.xx = ±0.04 (x.x = ±0.1); x.xxx = ±0.2 (x.xx = ±0.5)
04-Oct-11
ACDC
VCP24
Models and Ratings