AC-DC 150 Watts xppower.com AMM150 Series • Energy Star Level V ≥15 V • CEC 2008 & EISA2007 Compliant • Worldwide Medical Approvals • Class I and Class II Versions • Optional AC Cable Restraint • Optional Output Connectors • Low Leakage Current Specification Input General Input Voltage Input Frequency Input Current • 90-264 VAC • 47-63 Hz • 2 A rms at 115 VAC, 1 A rms at 230 VAC Earth Leakage Current • 90 µA max at 115 VAC/60 Hz, (Class I Versions) 150 µA max at 230 VAC/50 Hz Input Protection • Internal 3 A fuse in live and neutral lines No Load Input Power • <0.5 W Output Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • See table ±2% No minimum load required 2 s max at 115 VAC <80 ms at 115 VAC 15 ms at 110 VAC ±0.5% ±5% 4% deviation recovering to <1% within 300 µs for 25% step change Ripple & Noise • 2% pk-pk max, see note 1 Overvoltage Protection • 112-140% of nominal output voltage, auto recovery Overtemperature • Unit shuts down, auto recovery Protection Overload Protection • 130-180% auto recovery Short Circuit Protection • Trip & restart (hiccup mode) Temperature • ±0.04%/°C Coefficient Efficiency Isolation Switching Frequency Power Density MTBF • 85% minimum (see note 4) • 4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 50-110 kHz • 2.9 W/Inch3 • 150 kHrs per MIL-HDBK-217F Environmental Operating Temperature • 0 ºC to +60 ºC, derate linearly from 100% load at +40 °C to 50% at +60 °C Cooling • Natural convection Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 ºC to +85 ºC Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins on 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55011, Class B conducted EN55011, Class B radiated • EN61000-3-2, Class A • EN61000-3-3 • EN61000-4-2, ±8 kV air & ±6 kV indirect Discharge, Perf Criteria A • EN61000-4-3, level 2 Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A • EN61000-4-5, level 3 Perf Criteria A • EN61000-4-6, 3 V rms Perf Criteria A • EN61000-4-8, 1 A/m Perf Criteria A • EN61000-4-11, >95% UT for 10 ms, 60% UT for 100 ms, 30% UT for 500 ms Perf Criteria A, B, B • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL Output Power 132 W 144 W 150 W 150 W 150 W 150 W Output Voltage 12 V 15 V 19 V 24 V 27 V 48 V Output Current 11.00 A 9.60 A 7.90 A 6.25 A 5.56 A 3.13 A Total Regulation(2) 5% 5% 5% 5% 5% 5% Model Number(5,6) AMM150PS12 AMM150PS15 AMM150PS19 AMM150PS24(3) AMM150PS27(3) AMM150PS48(3) Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic capacitor connected at the measurement point. 2. Total regulation includes set accuracy, line and load regulation. 3. For optional barrel jack connector, add suffix ‘B1’ to the model number e.g. AMM150PS24B1. 4. Efficiency given is the average of efficiencies measured with output loads of 25%, 50%, 75% and 100%. Models with output voltage of 15 V and higher have 87% minimum. 5. For optional AC cable restraint on the Class I Version, add suffix ‘A’ to the model number e.g. AMM150PS24A or AMM150PS24B1A. AC mains lead must be Interpower Corporation, part number: 70006020300. Optional AC cable restraint is not available on the Class II Version. 6. For Class II Versions, and ‘C2’ to model number, eg. AMM150PS24C2 Mechanical Details Cable length approx 48” (1219 mm) 1 3 2 4 1.96 Power On Indicator (49.7) Pin 1 2 3 4 Rubber foot (4 places.) Function Return Output+ Return Output+ 8.17 (207.6) 3.23 (82.0) Optional Barrel Jack Connector 0.02 (0.5) 0.433 (11.0) 0.083 (2.1) 0.217 (5.5) 0.413 (10.5) AC Input IEC 320/C14 Inlet - For Class I Version IEC 320/C18 Inlet - For Class II Version Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 2.16 lbs (980 g). 3. Output connector is KYCON KPPX-4P. For mating half use KYCON KPJX-4S-S or equivalent. 4. For Class I versions shell is connected to ground. For Class II Versions shell is capacitively coupled to input. 02-Dec-08 AC-DC AMM150 Models and Ratings