POWERBOX VI-HAMD-IM

MODULES
VI-HAM
A C
I N P U T
H A R M O N I C
AT T E N U AT O R
M O D U L E
Features
•
•
•
•
•
•
•
Unity power factory
Safety agency approvals: UL478, 544, 1950;
CSA22.2 No. 234; EN60950
Meets EN61000-3-2 for line current harmonic
content
Universal input: 85–264VAC: 50/60Hz
Input surge current limiting
90–94% efficiency (typical)
UL, CSA, TUV, CE, C-Tick
Specifications
INPUT
Input voltage
STANDARDS AND APPROVALS
85–264VAC
Frequency (400Hz optional) 47Hz–63Hz
Power factor
0.99
Harmonic distortion
<8.5%
Inrush current (240VAC)
20A
Power factor correction
EN60555
Safety
UL1283, CSA C22.2 No.8, TÜV, VDE0560
EMI
The Ham required an external filter P/N07818
to meet IEC801-5 Level 3, EN55022 Level A,
AS/N25 2064 class A
C-Tick
AS/NZS CISPR11 Group 1 Class A
NOTE All VI-HAM versions must be preceded by three transorbs in series directly
across the input. Also use 10A 3AG fast blow fuse ahead of line filter.
OUTPUT
Output power
600/675W
Output ripple (pk-pk)
7mV pk-pk
Holdup capacitance
420–3000µF
Short circuit protection
Yes
MECHANICAL
Dimensions
117x61x12.7mm
OPERATING
Efficiency
90%–94%
Isolation
Input – Output: ZeroInput – Baseplate –
Output: 2500V rms
85°C
Baseplate operating
temperature
Thermal shutdown
90°C to 100°C
Typical Application
VI-HAM
252
If power requirements exceed one HAM, use a HAMD and one or more BAMDs, with an external
bridge rectifer. HAM, HAMD, and BAMD modules require three surge suppressors in series directly
across the input. These surge suppressors are already contained in the EMI filter P/N 30205. Also
use a 10A, 3AG fast-blow fuse ahead of the line filter.
* Compatible with V375 series.
PRODUCT
BASEPLATE
STORAGE
TYPICAL
GRADE
OPERATING TEMP TEMPERATURE SAMPLE
E-Grade
-10OC to +85OC
-20OC to +100OC
VI-HAM-EM
C-Grade
-20°C to +85°C
-40°C to +100°C
VI-HAM-CM
I-Grade
-40°C to +85°C
-55°C to +100°C
VI-HAM-IM
M-Grade
-55°C to +85°C
-65°C to +100°C
VI-HAM-MM