Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product information. It includes more installation, application, and technical information than ever before. Sensing and Control Honeywell Inc. 11 West Spring Street Freeport, Illinois 61032 Click this icon to try the new Interactive Catalog. Pressure Sensors Miniature Signal Conditioned 40PC Series FEATURES 1 Smallest amplified sensor package 1 Minimal PCB space 1 Fully signal conditioned 1 Operating temperature range from −45° to +125°C 1 Silicon piezoresistive technology 1 Monolithic design 1 6 Pin DIP package 1 Port designed for O-ring interface 1 Excellent media compatibility 1 Accuracy of 0.2% PERFORMANCE CHARACTERISTICS Pressure Range ±50 mm Hg 0-15 psi 0-100 psi 0-150 psi 0-250 psi Overpressure, max. ±170 mm Hg 45 psi 200 psi 300 psi 500 psi 5 VDC ±0.25 Supply Current 10 mA max. Output Source Current 0.5 mA max. Output Sink Current 1.0 mA max. Operating Temperature −45° to +125°C (−49° to +257°F) Storage Temperature −55° to +125°C (−67° to +257°F) Hysteresis & Repeatability 0.15% Span, Typ. Ratiometricity (at 4.75 to 5.25 Supply Voltage) ±0.25% Span, Typ. Output Load Capacitance Full Scale 0.05 microtarads, max. −50 mm Hg +50 mm Hg All other pressure ranges Media Compatibility Amplified Supply Voltage 0.50 VDC Typ. 4.50 VDC Typ. 4.50 VDC Typ. P1 port DRY GASES ONLY: Media must be compatible with epoxy based adhesive P2 port Media must be compatible with glass, silicon, stainless steel, invar, Sn/Ni plating or Sn/Ag solder 40PC SERIES ORDER GUIDE Catalog Listing Pressure Range psi Pressure Type 40PC001B1A ±50 mm Hg Bi-directional 1-unformed 40PC001B2A ±50 mm Hg Bi-directional 2-formed away from port Lead Style 40PC001B3A ±50 mm Hg Bi-directional 40PC015G1A 0-15 Gage 1-unformed 3-formed towards port 40PC015G2A 0-15 Gage 2-formed away from port 40PC015G3A 0-15 Gage 3-formed towards port 40PC100G1A 0-100 Gage 1-unformed 40PC100G2A 0-100 Gage 2-formed away from port 40PC100G3A 0-100 Gage 3-formed towards port 40PC150G1A 0-150 Gage 1-unformed 40PC150G2A 0-150 Gage 2-formed away from port 40PC150G3A 0-150 Gage 3-formed towards port 40PC250G1A 0-250 Gage 1-unformed 40PC250G2A 0-250 Gage 2-formed away from port 40PC250G3A 0-250 Gage 3-formed towards port Note: For tubing and O-Ring interface recommendations, see the 40PC Application Note in the Reference Section. Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 31 Pressure Sensors Miniature Signal Conditioned 40PC Series OUTPUT PERFORMANCE CHARACTERISTICS @ 25°C, 5VDC (unless otherwise noted) Pressure Range Null (VDC) ±50 mm Hg 2.50 ± 0.050 4.00 Typ. 0 to 15 psi 0 to 100 psi 0 to 150 psi 0 to 250 psi 0.50 ± 0.11 0.50 ± 0.04 0.50 ± 0.04 0.50 ± 0.04 Span (VDC) Linearity, B.F.S.L. (% Span) Max. Sensitivity, Typ. 4.00 ± 0.11 4.00 ± 0.09 4.00 ± 0.07 4.00 ± 0.07 40.0 mV/mm Hg 0.80 266.6 mV/psi 40.0 mV/psi 0.20 0.10 26.6 mV/psi 0.10 16.0 mV/psi 0.10 Null Shift (% Span) Max. Span ShIft (% Span) Max. Combined Null and Span Shift (% Span) Max. +25° to +50°C ±1.50 ±1.50 — +25° to 0°C ±1.50 ±1.50 — +25° to −18°C ±2.00 ±0.75 ±2.00 +25° to +63°C ±2.00 ±0.75 ±2.00 +25° to −45°C ±2.75 ±1.00 ±3.00 +25° to +85°C ±2.75 ±1.00 ±3.00 +25° to +125°C — — — +25° to −18°C ±1.25 ±0.75 ±1.50 +25° to +63°C ±1.25 ±0.75 ±1.50 +25° to −45°C ±2.00 ±1.00 ±2.50 +25° to +85°C ±2.00 ±1.00 ±2.50 +25° to +125°C ±3.00 ±2.00 ±3.00 +25° to −18°C ±0.75 ±0.75 ±0.75 +25° to +63°C ±0.75 ±0.75 ±0.75 +25° to −45°C ±1.00 ±1.00 ±1.00 +25° to +85°C ±1.00 ±1.00 ±1.00 +25° to +125°C ±1.50 ±1.50 ±1.50 +25° to −18°C ±0.75 ±0.75 ±0.75 +25° to +63°C ±0.75 ±0.75 ±0.75 +25° to −45°C ±1.00 ±1.00 ±1.00 +25° to +85°C ±1.00 ±1.00 ±1.00 +25° to +125°C ±2.00 ±2.00 ±3.00 PERFORMANCE SPECIFICATIONS, TEMPERATURE/ACCURACY Temperature Range Total Accuracy (% Span) Max. 0 to 15 psi 0 to 100 psi 0 to 150 psi 0 to 250 psi 25°C ±0.4 (RSS) ±0.2 (RSS) ±0.2 (RSS) ±0.2 (RSS) −18° to +63°C ±4.0 ±2.5 ±2.0 ±2.0 −45° to +85°C ±4.0 ±2.5 ±2.0 ±2.0 ±3.0 ±2.5 ±3.0 −45° to +125°C Note 1: Accuracy at 25°C is defined as RSS error for linearity, hysteresis, and repeatability. Note 2: Total accuracy is the maximum deviation from the 25°C reference transfer function at any pressure or temperature over the specified ranges. This calculation includes null, span, linearity, hysteresis, repeatability, null shift, and span shift. 32 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Pressure Sensors Miniature Signal Conditioned ELECTRICAL CONNECTION 40PC Series MOUNTING DIMENSIONS (for reference only) mm/In. Lead Style 1 NOTE: P1 - DRY GASES ONLY: Media must be compatible with epoxy based adhesive. P2 - Media must be compatible with glass, silicon, stainless steel, invar, Sn/Ni plating or Sn/Ag solder. Lead Style 2 Lead Style 3 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 33 Amplified NOTES: 1. Square corner marks pin 1 (Vs). 2. Output is short circuit protected.