ETC 40PC001B2A

Interactive Catalog Replaces Catalog Pages
Honeywell Sensing and Control has replaced
the PDF product catalog with the new
Interactive Catalog. The Interactive Catalog is
a power search tool that makes it easier to find
product information. It includes more
installation, application, and technical
information than ever before.
Sensing and Control
Honeywell Inc.
11 West Spring Street
Freeport, Illinois 61032
Click this icon to try the new
Interactive Catalog.
Pressure Sensors
Miniature Signal Conditioned
40PC Series
FEATURES
1 Smallest amplified sensor package
1 Minimal PCB space
1 Fully signal conditioned
1 Operating temperature range from −45° to +125°C
1 Silicon piezoresistive technology
1 Monolithic design
1 6 Pin DIP package
1 Port designed for O-ring interface
1 Excellent media compatibility
1 Accuracy of 0.2%
PERFORMANCE CHARACTERISTICS
Pressure Range
±50 mm Hg
0-15 psi
0-100 psi
0-150 psi
0-250 psi
Overpressure, max.
±170 mm Hg
45 psi
200 psi
300 psi
500 psi
5 VDC ±0.25
Supply Current
10 mA max.
Output Source Current
0.5 mA max.
Output Sink Current
1.0 mA max.
Operating Temperature
−45° to +125°C (−49° to +257°F)
Storage Temperature
−55° to +125°C (−67° to +257°F)
Hysteresis & Repeatability
0.15% Span, Typ.
Ratiometricity (at 4.75 to
5.25 Supply Voltage)
±0.25% Span, Typ.
Output Load Capacitance
Full Scale
0.05 microtarads, max.
−50 mm Hg
+50 mm Hg
All other pressure ranges
Media
Compatibility
Amplified
Supply Voltage
0.50 VDC Typ.
4.50 VDC Typ.
4.50 VDC Typ.
P1 port
DRY GASES ONLY: Media must be compatible with
epoxy based adhesive
P2 port
Media must be compatible with glass, silicon,
stainless steel, invar, Sn/Ni plating or Sn/Ag solder
40PC SERIES ORDER GUIDE
Catalog
Listing
Pressure Range
psi
Pressure
Type
40PC001B1A
±50 mm Hg
Bi-directional
1-unformed
40PC001B2A
±50 mm Hg
Bi-directional
2-formed away from port
Lead Style
40PC001B3A
±50 mm Hg
Bi-directional
40PC015G1A
0-15
Gage
1-unformed
3-formed towards port
40PC015G2A
0-15
Gage
2-formed away from port
40PC015G3A
0-15
Gage
3-formed towards port
40PC100G1A
0-100
Gage
1-unformed
40PC100G2A
0-100
Gage
2-formed away from port
40PC100G3A
0-100
Gage
3-formed towards port
40PC150G1A
0-150
Gage
1-unformed
40PC150G2A
0-150
Gage
2-formed away from port
40PC150G3A
0-150
Gage
3-formed towards port
40PC250G1A
0-250
Gage
1-unformed
40PC250G2A
0-250
Gage
2-formed away from port
40PC250G3A
0-250
Gage
3-formed towards port
Note: For tubing and O-Ring interface recommendations, see the 40PC Application Note in the Reference Section.
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
31
Pressure Sensors
Miniature Signal Conditioned
40PC Series
OUTPUT PERFORMANCE CHARACTERISTICS @ 25°C, 5VDC (unless otherwise noted)
Pressure
Range
Null
(VDC)
±50 mm Hg
2.50 ± 0.050 4.00 Typ.
0 to 15 psi
0 to 100 psi
0 to 150 psi
0 to 250 psi
0.50 ± 0.11
0.50 ± 0.04
0.50 ± 0.04
0.50 ± 0.04
Span
(VDC)
Linearity,
B.F.S.L.
(% Span) Max.
Sensitivity,
Typ.
4.00 ± 0.11
4.00 ± 0.09
4.00 ± 0.07
4.00 ± 0.07
40.0 mV/mm Hg 0.80
266.6 mV/psi
40.0 mV/psi
0.20
0.10
26.6 mV/psi
0.10
16.0 mV/psi
0.10
Null Shift
(% Span)
Max.
Span ShIft
(% Span)
Max.
Combined Null
and Span Shift
(% Span) Max.
+25° to +50°C
±1.50
±1.50
—
+25° to 0°C
±1.50
±1.50
—
+25° to −18°C
±2.00
±0.75
±2.00
+25° to +63°C
±2.00
±0.75
±2.00
+25° to −45°C
±2.75
±1.00
±3.00
+25° to +85°C
±2.75
±1.00
±3.00
+25° to +125°C
—
—
—
+25° to −18°C
±1.25
±0.75
±1.50
+25° to +63°C
±1.25
±0.75
±1.50
+25° to −45°C
±2.00
±1.00
±2.50
+25° to +85°C
±2.00
±1.00
±2.50
+25° to +125°C
±3.00
±2.00
±3.00
+25° to −18°C
±0.75
±0.75
±0.75
+25° to +63°C
±0.75
±0.75
±0.75
+25° to −45°C
±1.00
±1.00
±1.00
+25° to +85°C
±1.00
±1.00
±1.00
+25° to +125°C
±1.50
±1.50
±1.50
+25° to −18°C
±0.75
±0.75
±0.75
+25° to +63°C
±0.75
±0.75
±0.75
+25° to −45°C
±1.00
±1.00
±1.00
+25° to +85°C
±1.00
±1.00
±1.00
+25° to +125°C
±2.00
±2.00
±3.00
PERFORMANCE SPECIFICATIONS, TEMPERATURE/ACCURACY
Temperature
Range
Total Accuracy (% Span) Max.
0 to 15 psi
0 to 100 psi
0 to 150 psi
0 to 250 psi
25°C
±0.4 (RSS)
±0.2 (RSS)
±0.2 (RSS)
±0.2 (RSS)
−18° to +63°C
±4.0
±2.5
±2.0
±2.0
−45° to +85°C
±4.0
±2.5
±2.0
±2.0
±3.0
±2.5
±3.0
−45° to +125°C
Note 1: Accuracy at 25°C is defined as RSS error for linearity, hysteresis, and
repeatability.
Note 2: Total accuracy is the maximum deviation from the 25°C reference transfer
function at any pressure or temperature over the specified ranges. This
calculation includes null, span, linearity, hysteresis, repeatability, null shift,
and span shift.
32
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Pressure Sensors
Miniature Signal Conditioned
ELECTRICAL CONNECTION
40PC Series
MOUNTING DIMENSIONS (for reference only) mm/In.
Lead Style 1
NOTE:
P1 - DRY GASES ONLY: Media must be compatible with epoxy based adhesive.
P2 - Media must be compatible with glass, silicon, stainless steel, invar, Sn/Ni plating or
Sn/Ag solder.
Lead Style 2
Lead Style 3
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
33
Amplified
NOTES:
1. Square corner marks pin 1 (Vs).
2. Output is short circuit protected.