40PC Series Fully signal conditioned pressure transducer FEATURES · Pressure ranges from 0 ... ± 50 mmHg to 0 ... 500 psi gage · High accuracy · TTL power supply · Ratiometric 0.5 to 4.5 V output · Dual-Inline pinning for easy PCB-mounting · Excellent media compatibility MEDIA COMPATIBILITY P1: dry gases only P2: all media compatible with glass, silicon, stainless steel, Invar, Sn/Ni plating or Sn/Ag solder SPECIFICATIONS ELECTRICAL CONNECTION Maximum ratings Supply voltage (VS) Output current Source Sink Output load capacitance Temperature limits Operating Storage Compensated Humidity (non-condensing) November 2007 / 573 4.75 ... 5.25 V 0.5 mA 1.0 mA 10 nF NOTES: -45 to +125°C -55 to +125°C -45 to +125°C 1. Square corner marks pin 1 (Vs) 0 - 95 %RH 2. Output is short circuit protected 1/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer PRESSURE RANGE SPECIFICATIONS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Part number Operating pressure range Proof pressure1 Sensitivity (typ.) 40P C 001B 2A 0 ... ±50 mmHg 170 mmHg 40.0 mV/mmHg 40PC006G2A 0 ... 300 mmHg 650 mmHg 13.33 mV/mmHg 40PC015G2A 0 ... 15 psig 4 5 p si 266.7 mV/psi 40P C 015V 2A 0 ... -15 psig 3 0 p si -266.7 mV/psi 40PC030G2A 0 ... 30 psig 6 0 p si 133.3 mV/psi 40PC100G2A 0 ... 100 psig 2 0 0 p si 40.0 mV/psi 40PC150G2A 0 ... 150 psig 3 0 0 p si 25.7 mV/psi 40PC250G2A 0 ... 250 psig 5 0 0 p si 16.0 mV/psi 40PC500G2A 0 ... 500 psig 1 0 0 0 p si 8.0 mV/psi Specification notes: 1. 2. 3. 4. 5. 6. 2/8 Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full scale pressure). Thermal effects tested and guaranteed in the specified temperature ranges relative to 25°C. All specifications shown are relative to 25°C. Span is the algebraic difference between lowest and highest specified pressure. Total accuracy is the maximum deviation from the 25°C reference transfer function at any pressure or temperature over the specified ranges. This calculation includes null, span, linearity, hysteresis, repeatability, null shift and span shift. Response time for 0 to full-scale pressure step change, readings taken at 10 % and 90 % of full-scale pressure. November 2007 / 573 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC001B2A PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Operating pressure -50 Zero pressure offset 2.45 Typ. 2.50 4 Unit +50 mmHg 2.55 4.0 Span Output Thermal effects (0 to 50°C)3 at -50 mmHg 0.5 at +50 mmHg 4.5 V Offset ±1.50 Span ±1.50 2 Non-linearity (BSL) Hysteresis and repeatability ±0.15 Ratiometricity error (VS = 4.75 ... 5.25 V) ±0.25 Current consumption (no load) Response time Max. 6 40PC006G2A ±0.8 %FSS 10.0 mA 1 ms PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit 300 mmHg Operating pressure 0 Zero pressure offset 0.45 0.50 0.55 3.95 4.00 4.05 4 Span Full scale output Thermal effects3 4.5 Offset Span -18 to +63°C ±1.25 -45 to +125°C ±2.75 -18 to +63°C ±0.75 -45 to +125°C ±2.0 Combined offset and span -18 to +63°C Total accuracy5 ±1.5 -45 to +125°C ±4.0 -45 to +125°C ±4.0 Non-linearity (BSL)2 ±0.15 Ratiometricity error (VS = 4.75 ... 5.25 V) ±0.25 Current consumption (no load) November 2007 / 573 %FSS ±0.2 Hysteresis and repeatability Response time6 V 10.0 1 mA ms 3/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC015G2A PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 0 0.39 3.89 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 40PC015V2A Min. -18 -45 -18 -45 -18 -45 -45 to to to to to to to Typ. 0.50 4.00 4.5 +63°C +85°C +63°C +85°C +63°C +85°C +85°C Max. Unit 15 0.61 4.11 p si g ±2.0 ±2.75 ±0.75 ±1.0 ±2.0 ±3.0 ±4.0 ±0.2 V %FSS ±0.15 ±0.25 10.0 mA ms Max. Unit -15 0.54 4.1 p si g 1 PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 0 0.46 3.9 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 4/8 Min. Typ. 0.50 4.0 4.5 -18 to +25°C -45 to +85°C -18 to +25°C +25 to +85°C -45 to +25°C -18 to +25°C +25 to +85°C -40 to +25°C +45 to +85°C ±0.75 ±1.0 ±2.0 ±1.25 ±2.25 ±1.5 ±1.0 ±1.75 ±2.25 ±0.3 V %FSS ±0.15 ±0.25 10.0 1 mA ms November 2007 / 573 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC030G2A PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 0 0.46 3.92 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 40PC100G2A Min. -18 -45 -45 -18 -45 -45 -18 -45 -45 to to to to to to to to to Typ. 0.50 4.00 4.5 +63°C +85°C +125°C +63°C +85°C +125°C +63°C +125°C +125°C Max. Unit 30 0.54 4.08 p si g ±1.5 ±2.0 ±2.25 ±1.5 ±2.0 ±2.25 ±2.0 ±2.25 ±2.25 ±0.3 V %FSS ±0.15 ±0.25 10.0 mA ms Max. Unit 100 0.54 4.09 p si g 1 PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 0 0.46 3.91 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 November 2007 / 573 Min. -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to Typ. 0.50 4.0 4.5 +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C ±1.25 ±2.0 ±3.0 ±0.75 ±1.0 ±2.0 ±1.5 ±2.5 ±3.0 ±3.0 ±0.1 V %FSS ±0.15 ±0.25 10.0 1 mA ms 5/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC150G2A PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 0 0.46 3.93 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 40PC250G2A Min. -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to Typ. 0.50 4.0 4.5 +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C Max. Unit 150 0.54 4.07 p si g ±0.75 ±1.0 ±1.5 ±0.75 ±1.0 ±1.5 ±0.75 ±1.0 ±1.5 ±2.5 ±0.1 V %FSS ±0.15 ±0.25 10.0 mA ms Max. Unit 250 0.54 4.07 p si g 1 PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 0 0.46 3.93 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 6/8 Min. -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to Typ. 0.50 4.0 4.5 +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C ±0.75 ±1.0 ±2.0 ±0.75 ±1.0 ±2.0 ±0.75 ±1.0 ±3.0 ±3.0 ±0.1 V %FSS ±0.15 ±0.25 10.0 1 mA ms November 2007 / 573 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC500G2A PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Min. 0 0.46 3.91 Offset Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to Typ. 0.50 4.0 4.5 +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C Max. Unit 500 0.54 4.09 p si g ±1.0 ±1.5 ±2.5 ±0.75 ±1.0 ±1.5 ±1.0 ±1.75 ±3.0 ±3.0 ±0.2 V %FSS ±0.15 ±0.25 10.0 1 mA ms OUTLINE DRAWING mass: 4 g November 2007 / 573 dimensions in mm (inches) 7/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer ORDERING INFORMATION 40PC 40PC series Pressure range 001: 0 ... ±50 mmHg 006: 0 ... 300 mmHg 015: 0 ... 15 psi 015: 0 ... -15 psi 030: 0 ... 30 psi 100: 0 ... 100 psi 150: 0 ... 150 psi 250: 0 ... 250 psi 500: 0 ... 500 psi xxx x xA Lead forming 1: unformed (straight) 2: formed away from port 3: formed towards port 2: stocking devices 1, 3: call Sensortechnics for availability Pressure mode B: bidirectional gage pressure: available for ±50 mmHg only G: gage pressure V: vacuum gage: available for -15 psi only Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 8/8 November 2007 / 573 www.sensortechnics.com