ISAHAYA VLA307-02R

HYBRID IC
VLA307-02R
ISOLATED TYPE DC-DC CONVERTER
DESCRIPTION
The VLA307-02R is an isolated DC-DC converter designed
to control the industrial equipment. It can convert the high
OUTLINE DRAWING
voltage to low voltage 2 outputs. Total output power is
Dimensions : mm
76 MAX
11.2W.
FEATURES
•Output----------- +24V, 400mA (9.6W)
+8V, 200mA (1.6W)
VLA307-02R
XXXX
•Electrical isolation (between input and outputs)
3.5 +/-0.5
------------- 1500Vrms 1 minute
APPLICATIONS
On board power supply for control equipment
0.75
9.5 MAX
+0.15/-0.1
4MAX
2.54x27=68.58
4MAX
28
0.5 +0.2/-0.05
45MAX
•Input ------------ DC220V to 380V DC
12.5 MAX
21.5 MAX
1
BLOCK DIAGRAM
17 +Vo1
+V IN 4
CONSTANT
VOLTAGE
CIRCUIT
TEST 9
18 -Vo1
RS 10
22 IN
GATE
DRIVE
STEP
DOWN
OVER CURRENT
PROTECTION
24 +Vo2
-V IN 7
23 -Vo2
8
FEED BACK
1
11
12
19
20
NC
NC
NC
NC
NC NC
21
27
28
NC NC
HYBRID IC
VLA307-02R
ISOLATED TYPE DC-DC CONVERTER
MAXIMUM RATINGS (unless otherwise noted, Ta=25°C)
Symbol
Parameter
Conditions
Ratings
Unit
VIN
Input voltage
Between pins 4 - 7,8
380
V
IO1
Output current 1
Between pins 17 - 18,23
400
IO2
Output current 2
Between pins 24 - 18,23
200
Topr
Operating temperature
Tstg
Storage temperature
Viso
(*1)
-20 ~ +60
°C
No condensation
-20 ~ +80
°C
Sine wave voltage, 60Hz, 1min
1500
Vrms
No condensation
Electrical isolation
between input and output 1
Please refer to de-rating characteristics.
mA
(*1)
ELECTRICAL CHARACTERISTICS (unless otherwise noted, VIN=310V, Ta=25°C)
Symbol
Parameter
VIN
Input voltage
Vo1
Limits
Test conditions
Unit
Min.
Typ.
Max.
Recommended range
220
310
380
V
Output voltage 1
Io1=0 ~ 400mA
22.8
24.0
25.2
V
Vo2
Output voltage 2
Io2=0 ~ 200mA
7.6
8.0
8.4
V
Reg-I1
Input regulation 1
-
-
480
mV
Reg-I2
Input regulation 2
-
-
160
mV
Reg-L1
Load regulation 1
-
-
720
mV
Reg-L2
Load regulation 2
-
-
240
mV
Vp-p1
Ripple voltage 1
-
500
-
mV
-
100
-
mV
-
78
-
%
Io1=400mA, Io2=200mA
VIN=220~380V
Io1=0~400mA, Io2=0~200mA
Io1=400mA, Io2=200mA
Vp-p2
Ripple voltage 2
η
Efficiency
Io1=400mA, Io2=200mA
TEST CIRCUIT DIAGRAM
9
IO1
A
17
4
22
1W 100kΩ
IO2
x3
VIN
10
+
+
100μF
50V
7
18
8
23
1
11 12
19
20 21
27 28
It is used the electrolytic capacitors which has the low impedance for output capacitor.
2
VO 2
V
VO 1
+
A
24
VLA307-02R
V
Load
1
Load
2
470μF
470μF
50V
50V
HYBRID IC
VLA307-02R
ISOLATED TYPE DC-DC CONVERTER
FOR SAFETY USING
Great detail and careful attention are given to the production activity of Hics, such as the development, the quality of production,
and in it’s reliability. However the reliability of Hics depends not only on their own factors but also in their condition of usage.
When handling Hics, please note the following cautions.
CAUTIONS
Packing
Carrying
The materials used in packing Hics can only withstand normal external conditions.
When exposed to outside shocks, rain and certain environmental contaminators, the packing
materials will deteriorates. Please take care in handling.
1)
2)
3)
4)
5)
Don’t stack boxes too high. Avoid placing heavy materials on boxes.
Boxes must be positioned correctly during transportation to avoid breakage.
Don't throw or drop boxes.
Keep boxes dry. Avoid rain or snow.
Minimal vibration and shock during transportation is desirable.
Storage
When storing Hics, please observe the following notices or possible deterioration of their electrical
characteristics, risk of solderability, and external damage may occur.
1) Devices must be stored where fluctuation of temperature and humidity is minimal, and must
not be exposed to direct sunlight. Store at the normal temperature of 5 to 30 degrees Celsius
with humidity at 40 to 60%.
2) Avoid locations where corrosive gasses are generated or where much dust accumulates.
3) Storage cases must be static proof.
4) Avoid putting weight on boxes.
Extended storage
When extended storage is necessary, Hics must be kept non-processed. When using Hics which
have been stored for more than one year or under severe conditions, be sure to check that the
exterior is free from flaw and other damages.
Maximum ratings
To prevent any electrical damages, use Hics within the maximum ratings.
current, voltage, etc. must not exceed these conditions.
Polarity
To protect Hics from destruction and deterioration due to wrong insertion, make sure of polarity in
inserting leads into the board holes, conforming to the external view for the terminal arrangement.
3
The temperature,
HYBRID IC
VLA307-02R
ISOLATED TYPE DC-DC CONVERTER
Marketing division, Marketing planning department
6-41 Tsukuba, Isahaya, Nagasaki, 854-0065 Japan
Keep safety first in your circuit designs!
・ISAHAYA Electronics Corporation puts the maximum effort into making semiconductor products better and more reliable,
but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal
injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with
appropriate measures such as (1)placement of substitutive, auxiliary circuits, (2)use of non-flammable material or
(3)prevention against any malfunction or mishap.
Notes regarding these materials
・These materials are intended as a reference to our customers in the selection of the ISAHAYA products best suited to the
customer's application; they don't convey any license under any intellectual property rights, or any other rights, belonging
to ISAHAYA Electronics Corporation or a third party.
・ISAHAYA Electronics Corporation assumes no responsibility for any damage, or infringement of any third party's rights,
originating in the use of any product data, diagrams, charts or circuit application examples contained in these materials.
・All information contained in these materials, including product data, diagrams and charts, represent information on products
at the time of publication of these materials, and are subject to change by ISAHAYA Electronics Corporation without notice
due to product improvements or other reasons. It is therefore recommended that customers contact ISAHAYA Electronics
Corporation or an authorized ISAHAYA products distributor for the latest product information before purchasing a product
listed herein.
・ISAHAYA Electronics Corporation products are not designed or manufactured for use in a device or system that is used
under circumstances in which human life is potentially at stake. Please contact ISAHAYA Electronics Corporation or an
authorized ISAHAYA products distributor when considering the use of a product contained herein for any specific purposes,
such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
・The prior written approval of ISAHAYA Electronics Corporation is necessary to reprint or reproduce in whole or in part these
materials.
・If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a
license from the Japanese government and cannot be imported into a country other than the approved destination.
Any diversion or re-export contrary to the export control laws and regulations of Japan and/or the country of destination is
prohibited.
・Please contact ISAHAYA Electronics Corporation or an authorized ISAHAYA products distributor for further details on these
materials or the products contained therein.
4
July. 2007