VECTRON VVC2-FHB

VVC1/VVC2
Voltage Controlled Crystal Oscillator
Features
• VCXO with a CMOS output
• Small 5.0 X 7.0 X 1.8 mm package
• Output frequencies to 66 MHz
• 5.0 or 3.3 V operation
• Low Jitter < 6 pS rms, fo>12MHz
• Tri-State Output for test and board debug
• 0/70 or –40/85 °C operating temperature
• Hermetically sealed ceramic SMD package
• Product is compliant to RoHS directive
and fully compatible with lead free assembly
The VVC1 Voltage Controlled Crystal Oscillator
Applications
• SONET/SDH/DWDM
• Ethernet, Gigabit Ethernet
• xDSL/PCMCIA cards
• Digital Video
ESD Diodes
• Broadband Access
Vc
fO
Input
Buffer
Output
Buffer /
Tri-state
Description
Vectron’s VVC1 Voltage Controlled Crystal
Oscillator (VCXO) is a quartz stabilized square
wave generator with a CMOS output and is tested
at CMOS and TTL (5.0 volt operation) logic levels.
The VVC1 uses fundamental crystals resulting in
low jitter performance and a monolithic IC which
improves reliability and reduces cost.
Vectron International 267 Lowell Road, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VVC1 Voltage Controlled Crystal Oscillator
Performance Characteristics
Table 1. Electrical Performance
Parameter
Frequency
Supply Voltage 1
(+5.0 V)
(+3.3 V)
Supply Current
(+5.0 V)
(+3.3 V)
Output Logic Levels
Output Logic High2
Output Logic Low2
Transition Times
Rise Time2
Fall Time2
Symmetry or Duty Cycle3
Operating temperature (ordering option)
Total Pull Range (ordering option)
Or
Absolute Pull Range
Test Conditions for APR (+5V option)
Test Conditions for APR (+3.3V option)
Gain Transfer (See Figure 3)
Control Voltage Leakage Current
Control Voltage Bandwidth (-3dB)
Package Size
Symbol
fO
VDD
Min
1.544
4.750
3.135
Typical
Maximum
65.536
5.250
3.465
55
40
5.0
3.3
IDD
VOH
VOL
Units
MHz
V
mA
0.9*VDD
V
V
0.1V DD
tR
tF
SYM
45
VC
VC
0.5
0.3
50
0/70 or –40/85
±50, ±100 or ±150
5
5
55
ns
ns
%
°C
ppm
4.5
3.0
V
V
ppm/V
uA
kHz
mm
±50, ±80 or ±100
Positive
IVCXO
BW
±1
10
5.0 x 7.0 x 1.8
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 1 defines these parameters. Figure 2 illustrates the equivalent five gate TTL load and operating conditions under which
these parameters are tested and specified.
3. Symmetry is defined as (ON TIME/PERIOD with Vs= 1.4 V for TTL and Vs=2.5 V for CMOS, 5 volt operation, and Vs=1.65V
for 3.3 Volt operation.
tF
tR
IDD
650Ω
80 %
6
Vs
20 %
V DD
+
-
. 1µ F
.01µ F
1
2
5
3
4
IC
On Time
VC
Period
Figure 1. Output Waveform
Vectron International 267 Lowell Rd, Hudson NH 03051
+
-
15pF
1.8k
Figure 2. Typical Output Test Conditions (25±5°C)
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VVC1 Voltage Controlled Crystal Oscillator
Outline Diagram, Pad Layout and Pin Out
Inch/[mm}
Pin #
Symbol
Function
1
2
3
4
5
VC
NC or Tri-state
GND
fO
Tri-state or NC
6
V DD
Control Voltage
No Connect or Tri-state
Ground
Output Frequency
Logic low disables output
Logic high or no connection enables output waveform
Supply Voltage
Tape and Reel
J
F
D
G
C
B
A
I
L
E
H
Tape and Reel Dimensions (mm)
Tape Dimensions
Product
A
B
C
D
E
VVC1
12
5.5
1.5
4
K
Reel Dimensions
F
G
H
8
Vectron International 267 Lowell Rd, Hudson NH 03051
1.78
20.6
13
Tel: 1-88-VECTRON-1
I
J
K
L
55
6
12.4
178
e-mail: [email protected]
# Per
Reel
500
VVC1 Voltage Controlled Crystal Oscillator
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional
operation is not implied at these or any other conditions in excess of conditions represented in the
operational sections of this data sheet. Exposure to absolute maximum ratings for extended periods may
adversely affect device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Symbol
Power Supply
VDD
Storage Temperature
Tstorage
Voltage Control Range
VC
Ratings
6
-55/125
Gnd to VDD
Unit
Vdc
°C
V
200.0
150.0
Frequency Pull (ppm)
100.0
50.0
0.0
-50.0
-100.0
-150.0
-200.0
0.30
0.60
0.90
1.20
1.50
1.80
2.10
2.40
2.70
3.00
Control Voltage (volts)
Figure 3. Typical Frequency Pull versus Control Voltage, 35.328MHz Output, 3.3 Volt Supply
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VVC1 Voltage Controlled Crystal Oscillator
Reliability
The VVC1 is capable of meeting the following qualification tests.
Table 3. Environnemental Compliance
Parameter
Mechanical Shock
Mechanical Vibration
Solderability
Gross and Fine Leak
Resistance to Solvents
Conditions
MIL-STD-883 Method 2002
MIL-STD-883 Method 2007
MIL-STD-883 Method 2003
MIL-STD-883 Method 1014
MIL-STD-883 Method 2016
Handling Precautions
Although ESD protection circuitry has been designed into the the VVC1, proper precautions should be taken
when handling and mounting. VI employs a Human Body Model and a Charged-Device Model (CDM) for
ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit
parameters used to define the model. Although no industry wide standard has been adopted for the CDM, a
standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and therefore can be
used for comparison purposes.
Table 4. ESD Ratings
Model
Human Body Model
Charged Device Model
Minimum
1500
1000
Conditions
MIL-STD-883 Method 3115
JESD 22-C101
Suggested IR profile
Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow conditions.
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VVC1 Voltage Controlled Crystal Oscillator
Standard Frequencies (MHz)
1.544
2.048
4.096
8.192
10.000
12.000
12.288
12.352
13.000
14.318
15.440
16.000
16.384
18.432
19.440
20.000
20.480
24.576
24.704
27.000
30.000
32.000
32.768
34.368
35.328
38.880
40.000
40.960
44.736
51.840
52.000
62.208
65.536
Other frequencies may be available upon request. Standard frequencies are frequencies which the crystal has been designed
and does not imply a stock position.
Ordering Information
VVC1-BGE – xxMxxx
Product Family
Frequency
VC=VCXO
example: 44M736= 44.736MHz
Package
Temperature Range/Stability(for TPR)
5x7x2
B: 0/70 C, ±50 ppm
TriState
D: -40/85 C, ±50 ppm
1=Pin 5
E: 0/70 C, ±25 ppm
2=Pin 2
F: -40/85C, ±25 ppm
Power Supply, Linearity
Absolute Pull Range
A: 5.0V , 20% Linearity
G: ±50 ppm APR
B: 3.3V, 20% Linearity
N: ±80 ppm APR
C: 5.0V, 10% Linearity
H: ±100 ppm APR
F: 3.3V, 10% Linearity
or Total Pull Range
1: ±50 ppm
2: ±100 ppm
3: ±150 ppm
NOTE: Not all combinations of options are available. Higher frequencies have less pull capability, especially at +3.3 volts
supply, and higher pull can result in 20% linearity instead of 10%. Consult factory or your local sales representative with
application requirements.
For Additional Information, Please Contact:
www.vectron.com
USA: Vectron International • 267 Lowell Road, Hudson, NH 03051
• Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: VI Telefilter · Potsdamer Straße 18, 14513 Teltow, Germany
Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30
ASIA: Vectron Asia Pacific Sales 1F~2F. No.8 Workshop No.308 Fenju Rd., WaiGaoQiao
Free Trade Zone, Pudong New Area Shanghai, China 200131
•Tel: 8621 50480777 • Fax: 8621 50481881
Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. VVC1 (June 26 2005)
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]