Power Transformer 41FJ010 Input 115V AC 60Hz Pri. Sec. Electrical Specifications: • Primary Voltage: 115VAC, 60Hz • Primary Exciting Current: 80mA (max.) • Secondary Voltage (no load): 20.6VAC±5% • Secondary Voltage (full load): 18VAC±5% • Rated Secondary Current: 1 Amp (AC), 60Hz • Voltage Regulation: <L% (VNL-VFL) (VFL)x100 • Temperature Rise: <65˚C • Breakdown Voltage (HiPOT): 1500VAC, 50Hz, 1 minute • Coil to Coil Insulation: 100MΩ (min.), 500VDC Output 18V 1A C.T. Circuit Diagram for model 41FJ010 Mechanical Specifications: • Core Size: EI-57 • Core Material: HiLite Core H-23, 0.5mm Thick • Inner Insulation: Polyester Tape • Outer Wrap Insulation: Polyester Tape • Bobbin Material: Polybutylene Terephthalate • Impregnation: Varnished • Lead Wire: PRI: AWG22 Length- 210mm±10mm, Black, 10mm Tinned Lead SEC: AWG22 Length- 210mm±10mm, Red, 10mm Tinned Lead C.T.: AWG22 Length- 210mm±10mm, White, 10mm Tinned Lead XICON PASSIVE COMPONENTS • (800) 628-0544 XC-600052 Date Revised: 10/26/05 Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation.