XICOR X24325P-2.7

Preliminary Information
X24325
32K
4096 x 8 Bit
Advanced 2-Wire Serial E2PROM with Block LockTM Protection
FEATURES
DESCRIPTION
•
•
The X24325 is a CMOS 32,768 bit serial E2PROM,
internally organized 4096 x 8. The X24325 features a
serial interface and software protocol allowing operation on a simple two wire bus.
•
•
•
•
•
•
•
•
•
2.7V to 5.5V Power Supply
Low Power CMOS
—Active Read Current Less Than 1mA
—Active Write Current Less Than 3mA
—Standby Current Less Than 1µA
Internally Organized 4096 x 8
New Programmable Block Lock Protection
—Software Write Protection
—Programmable hardware Write Protect
Block Lock (0, 1/4, 1/2, or all of the E2PROM
array)
2 Wire Serial Interface
Bidirectional Data Transfer Protocol
32 Byte Page Write Mode
—Minimizes Total Write Time Per Byte
Self Timed Write Cycle
—Typical Write Cycle Time of 5ms
High Reliability
—Endurance: 100,000 Cycles
—Data Retention: 100 Years
Available Packages
—8-Lead PDIP
—8-Lead SOIC (JEDEC)
—14-Lead TSSOP
Three device select inputs (S0, S1, S2) allow up to
eight devices to share a common two wire bus.
A Write Protect Register at the highest address location, FFFh, provides three new write protection
features: Software Write Protect, Block Write Protect,
and Hardware Write Protect. The Software Write
Protect feature prevents any nonvolatile writes to the
X24325 until the WEL bit in the write protect register is
set. The Block Write Protection feature allows the user
to individually write protect four blocks of the array by
programming two bits in the write protect register. The
Programmable Hardware Write Protect feature allows
the user to install the X24325 with WP tied to VCC,
program the entire memory array in place, and then
enable the hardware write protection by programming
a WPEN bit in the write protect register. After this,
selected blocks of the array, including the write protect
register itself, are permanently write protected.
Xicor E2PROMs are designed and tested for applications requiring extended endurance. Inherent data
retention is greater than 100 years.
FUNCTIONAL DIAGRAM
WP
H.V. GENERATION
TIMING &
CONTROL
START CYCLE
VCC
VSS
SDA
WRITE PROTECT
REGISTER AND
LOGIC
START
STOP
LOGIC
CONTROL
LOGIC
SCL
SLAVE ADDRESS
REGISTER
+COMPARATOR
LOAD
INC
E2PROM
128 X 256
XDEC
WORD
ADDRESS
COUNTER
S0
S1
S2
R/W
YDEC
8
CK
PIN
DATA REGISTER
DOUT
DOUT
ACK
Xicor, 1995, 1996 Patents Pending
6552-2.4 5/13/96 T1/C10/D0 NS
1
6552 ILL F01.1
Characteristics subject to change without notice
X24325
PIN DESCRIPTIONS
PIN CONFIGURATIONS
Serial Clock (SCL)
The SCL input is used to clock all data into and out of
the device.
8-LEAD DIP & SOIC
Serial Data (SDA)
SDA is a bidirectional pin used to transfer data into
and out of the device. It is an open drain output and
may be wire-ORed with any number of open drain or
open collector outputs.
S0
1
8
VCC
S1
2
7
WP
S2
3
6
SCL
VSS
4
5
SDA
X24325
14-LEAD TSSOP
An open drain output requires the use of a pull-up
resistor. For selecting typical values, refer to the PullUp Resistor selection graph at the end of this data
sheet.
S0
1
14
VCC
S1
NC
2
13
WP
3
12
NC
NC
4
X24325 11
NC
Device Select (S0, S1, S2)
NC
5
10
NC
The device select inputs (S0, S1, S2) are used to set
the first three bits of the 8-bit slave address. This
allows up to eight X24325’s to share a common bus.
These inputs can be static or actively driven. If used
statically they must be tied to VSS or VCC as appropriate. If actively driven, they must be driven with
CMOS levels (driven to VCC or VSS).
S2
6
9
SCL
VSS
7
8
SDA
6552 ILL F02.5
Write Protect (WP)
The write protect input controls the hardware write
protect feature. When held LOW, hardware write
protection is disabled and the X24325 can be written
normally. When this input is held HIGH, and the WPEN
bit in the write protect register is set HIGH, write
protection is enabled, and nonvolatile writes are
disabled to the selected blocks as well as the write
protect register itself.
PIN NAMES
Symbol
Description
S0, S1, S2
Device Select Inputs
SDA
Serial Data
SCL
Serial Clock
WP
Write Protect
VSS
Ground
VCC
Supply Voltage
NC
No Connect
6552 FRM T01.1
2
X24325
Clock and Data Conventions
Data states on the SDA line can change only during
SCL LOW. SDA state changes during SCL HIGH are
reserved for indicating start and stop conditions. Refer
to Figures 1 and 2.
DEVICE OPERATION
The X24325 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data
onto the bus as a transmitter, and the receiving device
as the receiver. The device controlling the transfer is a
master and the device being controlled is the slave.
The master will always initiate data transfers, and provide the clock for both transmit and receive operations.
Therefore, the X24325 will be considered a slave in all
applications.
Start Condition
All commands are preceded by the start condition,
which is a HIGH to LOW transition of SDA when SCL is
HIGH. The X24325 continuously monitors the SDA and
SCL lines for the start condition and will not respond to
any command until this condition has been met.
Figure 1. Data Validity
SCL
SDA
DATA STABLE
DATA
CHANGE
6552 ILL F04
Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V)
(6) tWR is the minimum cycle time from the system perspective when polling techniques are not used. It is the maximum time the
device requires to perform the internal write operation.
Figure 2. Definition of Start and Stop
SCL
SDA
START BIT
STOP BIT
3
6552 ILL F05
X24325
The X24325 will respond with an acknowledge after
recognition of a start condition and its slave address. If
both the device and a write operation have been
selected, the X24325 will respond with an acknowledge after the receipt of each subsequent eight-bit
word.
Stop Condition
All communications must be terminated by a stop
condition, which is a LOW to HIGH transition of SDA
when SCL is HIGH. The stop condition is also used to
place the device into the standby power mode after a
read sequence. A stop condition can only be issued
after the transmitting device has released the bus.
In the read mode the X24325 will transmit eight bits of
data, release the SDA line and monitor the line for an
acknowledge. If an acknowledge is detected and no
stop condition is generated by the master, the X24325
will continue to transmit data. If an acknowledge is not
detected, the X24325 will terminate further data transmissions. The master must then issue a stop condition
to return the X24325 to the standby power mode and
place the device into a known state.
Acknowledge
Acknowledge is a software convention used to indicate
successful data transfer. The transmitting device,
either master or slave, will release the bus after transmitting eight bits. During the ninth clock cycle the
receiver will pull the SDA line LOW to acknowledge
that it received the eight bits of data. Refer to Figure 3.
Figure 3. Acknowledge Response From Receiver
SCL FROM
MASTER
1
8
9
DATA OUTPUT
FROM
TRANSMITTER
DATA
OUTPUT
FROM
RECEIVER
START
ACKNOWLEDGE
6552 ILL F06
4
X24325
DEVICE ADDRESSING
The last bit of the slave address defines the operation to
be performed. When set HIGH a read operation is
selected, when set LOW a write operation is selected.
Following a start condition the master must output the
address of the slave it is accessing (see Figure 4). The
next three bits are the device select bits. A system
could have up to eight X24325’s on the bus. The eight
addresses are defined by the state of the S0, S1 and
S2 inputs. S0 and S2 of the slave address must be the
inverse of the S0 and S2 input pins.
Following the start condition, the X24325 monitors the
SDA bus comparing the slave address being transmitted
with its slave address device type identifier. Upon a
correct compare the X24325 outputs an acknowledge on
the SDA line. Depending on the state of the R/W bit, the
X24325 will execute a read or write operation.
Figure 4. Slave Address
S2
S1
WRITE OPERATIONS
HIGH ORDER
WORD
ADDRESS
DEVICE
SELECT
S0
A11
A10
A9
A8
Byte Write
For a write operation, the X24325 requires a second address field. This address field is the word address, comprised of eight bits, providing access to any one of 4096
words in the array. Upon receipt of the word address, the
X24325 responds with an acknowledge and awaits the
next eight bits of data, again responding with an acknowledge. The master then terminates the transfer by generating a stop condition, at which time the X24325 begins
the internal write cycle to the nonvolatile memory. While
the internal write cycle is in progress the X24325 inputs
are disabled, and the device will not respond to any requests from the master. Refer to Figure 5 for the address,
acknowledge and data transfer sequence.
R/W
6552 ILL F07.2
The next four bits of the slave address are an extension of the array’s address and are concatenated with
the eight bits of address in the word address field,
providing direct access to the whole 4096 x 8 array.
Figure 5. Byte Write
BUS ACTIVITY:
MASTER
SDA LINE
BUS ACTIVITY:
X24325
S
T
A
R
T
SLAVE
ADDRESS
WORD
ADDRESS
S
T
O
P
DATA
S
P
A
C
K
A
C
K
A
C
K
6552 ILL F08
5
X24325
Page Write
The X24325 is capable of a 32 byte page write operation. It is initiated in the same manner as the byte write
operation, but instead of terminating the write cycle after the first data word is transferred, the master can
transmit up to fifteen more words. After the receipt of
each word, the X24325 will respond with an acknowledge.
Flow 1. ACK Polling Sequence
WRITE OPERATION
COMPLETED
ENTER ACK POLLING
ISSUE
START
After the receipt of each word, the five low order address bits are internally incremented by one. The high
order bits of the word address remain constant. If the
master should transmit more than 32 words prior to
generating the stop condition, the address counter will
“roll over” and the previously written data will be overwritten. As with the byte write operation, all inputs are
disabled until completion of the internal write cycle. Refer to Figure 6 for the address, acknowledge and data
transfer sequence.
ISSUE SLAVE
ADDRESS AND R/W = 0
ACK
RETURNED?
ISSUE STOP
NO
YES
Acknowledge Polling
The Max Write Cycle Time can be significantly reduced
using Acknowledge Polling. To initiate Acknowledge
Polling, the master issues a start condition followed by
the Slave Address Byte for a write or read operation. If
the device is still busy with the high voltage cycle, then
no ACK will be returned. If the device has completed
the write operation, an ACK will be returned and the
host can then proceed with the read or write operation.
Refer to Flow 1.
NEXT
OPERATION
A WRITE?
NO
YES
ISSUE BYTE
ADDRESS
ISSUE STOP
PROCEED
PROCEED
6552 ILL F09
Figure 6. Page Write
BUS ACTIVITY:
MASTER
SDA LINE
BUS ACTIVITY:
X24325
S
T
A
R
T
SLAVE
ADDRESS
WORD ADDRESS (n)
DATA n
DATA n+1
S
T
O
P
DATA n+31
S
P
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
6552 ILL F10.1
6
X24325
minated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to
Figure 7 for the sequence of address, acknowledge
and data transfer.
READ OPERATIONS
Read operations are initiated in the same manner as
write operations with the exception that the R/W bit of
the slave address is set HIGH. There are three basic
read operations: current address read, random read
and sequential read.
Random Read
Random read operations allow the master to access
any memory location in a random manner. Prior to issuing the slave address with the R/W bit set HIGH, the
master must first perform a “dummy” write operation.
The master issues the start condition, and the slave address with the R/W bit set LOW, followed by the word
address it is to read. After the word address acknowledge, the master immediately reissues the start condition and the slave address with the R/W bit set HIGH.
This will be followed by an acknowledge from the
X24325 and then by the eight-bit word. The read operation is terminated by the master; by not responding
with an acknowledge and by issuing a stop condition.
Refer to Figure 8 for the address, acknowledge and
data transfer sequence.
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read operation, the master must either issue a stop condition
during the ninth cycle or hold SDA HIGH during the
ninth clock cycle and then issue a stop condition.
Current Address Read
Internally the X24325 contains an address counter that
maintains the address of the last word read, incremented by one or the exact address of the last word written.
Therefore, if the last access read was to address n, the
next read operation would access data from address
n + 1. Upon receipt of the slave address with the R/W
set HIGH, the X24325 issues an acknowledge and
transmits the eight-bit word. The read operation is ter-
Figure 7. Current Address Read
BUS ACTIVITY:
MASTER
SDA LINE
S
T
A
R
T
S
T
O
P
SLAVE
ADDRESS
S
P
A
C
K
BUS ACTIVITY:
X24325
DATA
6552 ILL F11
Figure 8. Random Read
BUS ACTIVITY:
MASTER
SDA LINE
BUS ACTIVITY:
X24325
S
T
A
R
T
SLAVE
ADDRESS
S
T
A
R
T
WORD
ADDRESS n
S
S
T
O
P
SLAVE
ADDRESS
S
A
C
K
A
C
K
P
A
C
K
DATA n
6552 ILL F12.1
7
X24325
The data output is sequential, with the data from
address n followed by the data from n + 1. The address
counter for read operations increments all address bits,
allowing the entire memory contents to be serially read
during one operation. At the end of the address space
(address 4095), the counter “rolls over” to 0 and the
X24325 continues to output data for each acknowledge
received. Refer to Figure 9 for the address,
acknowledge and data transfer sequence.
Sequential Read
Sequential reads can be initiated as either a current
address read or random access read. The first word is
transmitted as with the other modes, however, the
master now responds with an acknowledge, indicating
it requires additional data. The X24325 continues to
output data for each acknowledge received. The read
operation is terminated by the master; by not
responding with an acknowledge and then issuing a
stop condition.
Figure 9. Sequential Read
BUS ACTIVITY:
MASTER
SLAVE
ADDRESS
A
C
K
A
C
K
S
T
O
P
A
C
K
SDA LINE
BUS ACTIVITY:
X24325
P
A
C
K
DATA n
DATA n+1
DATA n+2
DATA n+x
6552 ILL F13
Figure 10. Typical System Configuration
VCC
PULL-UP
RESISTORS
SDA
SCL
MASTER
TRANSMITTER/
RECEIVER
SLAVE
RECEIVER
SLAVE
TRANSMITTER/
RECEIVER
MASTER
TRANSMITTER
MASTER
TRANSMITTER/
RECEIVER
6552 ILL F14
8
X24325
WEL and RWEL are volatile latches that power-up in
the LOW (disabled) state. A write to any address other
than FFFh, where the Write Protect Register is
located, will be ignored (no ack) until the WEL bit is set
HIGH. The WEL bit is set by writing 0000001x to
address FFFh. Once set, WEL remains HIGH until
either reset (by writing 00000000 to FFFh) or until the
part powers-up again. The RWEL bit controls writes to
the block protect bits. RWEL is set by first setting WEL
= 1 and then writing 0000011x to address FFFh.
RWEL must be set in order to change the block protect
bits, BP0 and BP1, or the WPEN bit. RWEL is reset
when the block protect or WPEN bits are changed, or
when the part powers-up again.
WRITE PROTECT REGISTER
The Write Protect Register (WPR) is located at the
highest address, FFFh.
Figure 11. Write Protect Register
WPR (Addr = FFFh)
7
6
5
4
3
2
1
0
WPEN
0
0
BP1
BP0
RWEL
WEL
0
6552 ILL F15
WPR.1 = WEL
– Write Enable Latch (Volatile)
0 = Write enable latch reset, writes disabled
1 = Write enable latch set, writes enabled
Programming the BP or WPEN Bits
A three step sequence is required to change the
nonvoltaile Block Protect or Write Protect Enable:
If WEL = 0 then “no ACK” after first byte of input data.
WPR.2 = RWEL
– Register Write Enable Latch (Volatile)
0 = Register write enable latch reset, writes disabled
1 = Register write enable latch set, writes enabled
1) Set WEL = 1 (write 00000010 to address FFFh,
volatile write cycle)
(Start)
2) Set RWEL = 1 (write 00000110 to address FFFh,
volatile write cycle)
WPR.3, WPR.4 = BP0, BP1
– Block Protect Bits (Nonvolatile)
(See Block Protect section for definition)
(Start)
WPR.7 = WPEN
– Write Protect Enable Bit (Nonvolatile)
(See Hardware Write Protect section for definition)
3) Set BP1, BP0, and/or WPEN bits (Write w00yz010
to address FFFh)
w = WPEN, y = BP1, Z = BP0,
Writing to the Write Protect Register
The Write Protect Register is written by performing a
random write of one byte directly to address, FFFh. If a
page write is performed starting with any address
other than FFFh, the byte in the array at address FFFh
will be written instead of the Write Protect Register
(assuming writes are not disabled by the block protect
register).
(Stop)
Step 3 is a nonvolatile write cycle, requiring 10ms to
complete. RWEL is reset (0) by this write cycle,
requiring another write cycle to set RWEL again before
the block protect bits can be changed. RWEL must be
0 in step 3; if w00yz110 is written to address FFFh,
RWEL is set but WPEN, BP1 and BP0 are not
changed (the device remains at step 2).
The state of the Write Protect Register can be read by
performing a random read at address FFFh at any
time. If a sequential read starting at any other address
than FFFh is performed, the contents of the byte in the
array at FFFh is read out instead of the Write Protect
Register.
9
X24325
Block Protect Bits
The Block Protect Bits BP0 and BP1 determine which
blocks of the memory are write-protected:
Programmable Hardware Write Protect
The Write Protect (WP) pin and the Write Protect
Enable (WPEN) bit in the Write Protect Register
control the programmable hardware write protect
feature. Hardware write protection is enabled when the
WP pin and the WPEN bit are both HIGH, and
disabled when either the WP pin is LOW or the WPEN
bit is LOW. When the chip is hardware write-protected,
nonvolatile writes are disabled to the Write Protect
Register, including the BP bits and the WPEN bit itself,
as well as to block-protected sections in the memory
array. Only the sections of the memory array that are
not block-protected can be written. Note that since the
WPEN bit is write-protected, it cannot be changed
back to a LOW state, and write protection is disabled
as long as the the WP pin is held HIGH. Table 2
defines the write protection status for each state of
WPEN and WP.
Table 1. Block Protect Bits
Protected
Addresses
BP1
BP0
0
0
None
0
1
C00h–FFFh
Upper 1/4
1
0
800h–FFFh
Upper 1/2
1
1
0000h–FFFh
Full Array (WPR
not included)
6552 FRM T02
Table 2. Write Protect Status Table
WP
WPEN
Memory Array
(Not Block
Protected)
0
X
Writable
Protected
Writable
Writable
X
0
Writable
Protected
Writable
Writable
1
1
Writable
Protected
Protected
Protected
Memory Array
(Block Protected)
BP Bits
WPEN Bit
6552 FRM T03
10
X24325
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias
X24325.......................................–65°C to +135°C
Storage Temperature ........................–65°C to +150°C
Voltage on any Pin with
Respect to VSS .................................... –1V to +7V
D.C. Output Current ..............................................5mA
Lead Temperature (Soldering, 10 Seconds) ...... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
4.5V to 5.5V
2.7V to 5.5V
Commercial
0°C
+70°C
X24325
Industrial
–40°C
+85°C
X24325-2.7
Military
–55°C
+125°C
6552 FRM T05
6552 FRM T04
D.C. OPERATING CHARACTERISTICS
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
ICC1
VCC Supply Current (Read)
1
mA
ICC2
VCC Supply Current (Write)
3
mA
SCL = VCC X 0.1/VCC X 0.9 Levels
@ 100KHz, SDA = Open, All Other
Inputs = VSS or VCC – 0.3V
ISB1(1)
VCC Standby Current
50
µA
SCL = SDA = VCC, All Other
Inputs = VSS or VCC – 0.3V,
VCC = 5V ± 10%
ISB2(1)
VCC Standby Current
1
µA
SCL = SDA = VCC, All Other
Inputs = VSS or VCC – 0.3V,
VCC = 2.7V
ILI
Input Leakage Current
10
µA
VIN = VSS to VCC
ILO
Output Leakage Current
10
µA
VOUT = VSS to VCC
VlL(2)
Input LOW Voltage
–1
VCC x 0.3
V
VIH(2)
Input HIGH Voltage
VCC x 0.7
VCC + 0.5
V
VOL
Output LOW Voltage
0.4
V
IOL = 3mA, VCC = 4.5V
6552 FRM T06.1
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Parameter
Max.
Units
Test Conditions
CI/O(3)
Input/Output Capacitance (SDA)
8
pF
VI/O = 0V
CIN(3)
Input Capacitance (S1, S2, SCL)
6
pF
VIN = 0V
6552 FRM T07.1
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not 100% tested.
(3) This parameter is periodically sampled and not 100% tested.
11
X24325
EQUIVALENT A.C. LOAD CIRCUIT
A.C. CONDITIONS OF TEST
Input Pulse Levels
VCC x 0.1 to VCC x 0.9
Input Rise and
Fall Times
5V
10ns
Input and Output
Timing Levels
1533Ω
OUTPUT
VCC X 0.5
6552 FRM T08.1
100pF
6552 ILL F16
A.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.)
Read & Write Cycle Limits
Symbol
Parameter
Min.
Max.
Units
0
100
KHz
100
ns
3.5
µs
fSCL
SCL Clock Frequency
TI
Noise Suppression Time
Constant at SCL, SDA Inputs
tAA
SCL LOW to SDA Data Out Valid
0.3
tBUF
Time the Bus Must Be Free Before a
New Transmission Can Start
4.7
µs
tHD:STA
Start Condition Hold Time
4
µs
tLOW
Clock LOW Period
4.7
µs
tHIGH
Clock HIGH Period
4
µs
tSU:STA
Start Condition Setup Time
(for a Repeated Start Condition)
4.7
µs
tHD:DAT
Data In Hold Time
0
µs
tSU:DAT
Data In Setup Time
250
ns
tR
SDA and SCL Rise Time
1
µs
tF
SDA and SCL Fall Time
300
ns
tSU:STO
Stop Condition Setup Time
4.7
µs
tDH
Data Out Hold Time
300
ns
6552 FRM T09.1
POWER-UP TIMING(4)
Symbol
Parameter
Max.
Units
tPUR
Power-up to Read Operation
1
ms
tPUW
Power-up to Write Operation
5
ms
6552 FRM T10
Notes: (4) tPUR and tPUW are the delays required from the time V CC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
12
X24325
Bus Timing
tHIGH
tF
tLOW
tR
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA IN
tAA
tDH
tBUF
SDA OUT
6552 ILL F17
Write Cycle Limits
Symbol
Parameter
tWR(6)
Write Cycle Time
Min.
Typ.(5)
Max.
Units
5
10
ms
6552 FRM T11.1
The write cycle time is the time from a valid stop
condition of a write sequence to the end of the internal
erase/program cycle. During the write cycle, the
X24325 bus interface circuits are disabled, SDA is
allowed to remain HIGH, and the device does not
respond to its slave address.
Bus Timing
SCL
SDA
8th BIT
ACK
WORD n
tWR
STOP
CONDITION
START
CONDITION
6552 ILL F18
Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V).
(6) tWR is the minimum cycle time to be allowed from the system perspective unless polling techniques are used. It is the maximum
time the device requires to automatically complete the internal write operation.
Guidelines for Calculating Typical Values of
Bus Pull-Up Resistors
SYMBOL TABLE
WAVEFORM
RESISTANCE (KΩ)
120
RMIN =
100
80
VCC MAX
=1.8KΩ
IOL MIN
RMAX =
tR
CBUS
MAX.
RESISTANCE
60
40
20
MIN.
RESISTANCE
0
0
20
40
60
80 100 120
BUS CAPACITANCE (pF)
6552 ILL F19
13
INPUTS
OUTPUTS
Must be
steady
Will be
steady
May change
from LOW
to HIGH
Will change
from LOW
to HIGH
May change
from HIGH
to LOW
Will change
from HIGH
to LOW
Don’t Care:
Changes
Allowed
N/A
Changing:
State Not
Known
Center Line
is High
Impedance
X24325
PACKAGING INFORMATION
8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.260 (6.60)
0.240 (6.10)
PIN 1 INDEX
PIN 1
0.300
(7.62) REF.
HALF SHOULDER WIDTH ON
ALL END PINS OPTIONAL
0.145 (3.68)
0.128 (3.25)
SEATING
PLANE
0.025 (0.64)
0.015 (0.38)
0.065 (1.65)
0.045 (1.14)
0.150 (3.81)
0.125 (3.18)
0.020 (0.51)
0.016 (0.41)
0.110 (2.79)
0.090 (2.29)
0.015 (0.38)
MAX.
0.060 (1.52)
0.020 (0.51)
0.325 (8.25)
0.300 (7.62)
0°
15°
TYP. 0.010 (0.25)
NOTE:
1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
3926 FHD F01
14
X24325
PACKAGING INFORMATION
8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.010 (0.25)
X 45°
0.020 (0.50)
0.050" TYPICAL
0.050"
TYPICAL
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.410)
0.037 (0.937)
0.030"
TYPICAL
8 PLACES
FOOTPRINT
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F22.1
15
X24325
PACKAGING INFORMATION
14-LEAD PLASTIC, TSSOP PACKAGE TYPE V
.025 (.65) BSC
.169 (4.3)
.252 (6.4) BSC
.177 (4.5)
.193 (4.9)
.200 (5.1)
.047 (1.20)
.0075 (.19)
.0118 (.30)
.002 (.05)
.006 (.15)
.010 (.25)
Gage Plane
0° – 8°
Seating Plane
.019 (.50)
.029 (.75)
Detail A (20X)
.031 (.80)
.041 (1.05)
See Detail “A”
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F32
16
X24325
ORDERING INFORMATION
X24325
X
X
-X
VCC Range
Blank = 4.5V to 5.5V
2.7 = 2.7V to 5.5V
Device
Temperature Range
Blank = 0°C to +70°C
I = –40°C to +85°C
M = –55°C to +125°C
Package
P = 8-Lead Plastic DIP
S = 8-Lead SOIC (JEDEC)
V = 14-Lead TSSOP
Part Mark Convention
X24325
X
P = 8-Lead Plastic DIP
Blank = 8-Lead SOIC (JEDEC)
V = 14-Lead TSSOP
X
Blank = 4.5V to 5.5V, 0°C to +70°C
I = 4.5V to 5.5V, –40°C to +85°C
F = 2.7V to 5.5V, 0°C to +70°C
G = 2.7V to 5.5V, –40°C to +85°C
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc.
makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the
described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the
right to discontinue production and change specifications and prices at any time and without notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents,
licenses are implied.
U.S. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481;
4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967;
4,883, 976. Foreign patents and additional patents pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with
appropriate error detection and correction, redundancy and back-up features to prevent such an occurence.
Xicor's products are not authorized for use in critical components in life support devices or systems.
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain
life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system, or to affect its safety or effectiveness.
17