ALLEN-BRADLEY 440T

Prosafe Trapped Key Interlock Switches
Slamlock Electrical
Specifications
Standards
Single
Dual
Description
The Prosafe Slamlock with electrical isolation combines the features
of trapped key tongue actuated interlocks while also providing sets
of electrical safety and auxiliary contacts. When the actuator is
inserted into the lock and the key is removed the actuator is trapped
in the unit thus locking closed the guard door. In this state the safety
contacts are closed and the auxiliary contacts are open. To open the
guard door the key must be inserted and rotated 90°, opening the
safety contacts, closing the auxiliary contacts and enabling the
actuator to be released thus unlocking the guard door. While the
guard door is open the key is trapped in the unit.
Slamlocks with electrical isolation offer the features of electrical
safety interlock switches with the benefits of a trapped key/enforced
sequence systems. They allow a combination of both approaches for
safeguarding machinery and processes to be used.
The single key Slamlock (SSS) is used to interlock hatches, guards
and doors where full body access is not required. The single key
locks the actuator and operates the switch in the same action.
Dual key Slamlock (DSS) is similar to the single key version but has a
secondary key to allow ‘2 key in’ or ‘key exchange’ conditions. The
key exchange version may be used where whole body access is
required, as the secondary key can be used as a personnel key.
Features
• Electrical safety contacts combined with trapped key/enforced
sequence feature
• Most of unit constructed from 316L stainless steel
• Selection of actuator types available
• Single or dual key versions available
• Direct drive operation
• Replaceable code barrel assembly
• Weatherproof stainless steel dust cap as standard
EN292-1&2, EN1088, IEC/EN60947-5-1,
GS-ET-19, ISO12100-1&2, ISO14119,
AS4024.1
Category
Cat. 1 per EN 954-1 (ISO 13849-1)
Suitable for Cat. 2, 3, or 4 systems
Approvals
BG, CE marked for all applicable
directives, and C-Tick not required
Safety Contact
2 N.C. positive break
Utilization Category
AC 15
AC (Ue) 500V 250V 100V
(le) 1A 2A 5A
DC 250V 0.5A, 24V 2A
Max. Switched Current/
500V/500V A
Voltage/Load
Thermal Current (lth)
10A
Minimum Current
5V 5mA DC
Safety Contact Gap
>2 x 2mm (0.07in)
Rtd. Insulation Voltage
(Ui) 500V
Rtd. Impulse Withstand Volt. (Uimp) 2500V
Auxiliary Contacts
1 N.O.
Pollution Degree
3
Actuator Travel-Pos.
5mm (0.19in)
Opening
Minimum Operating Radius
175mm (6.88in) (60mm (2.36in) with
flexible actuator)
Break Contact Min. Force
12N (2.7lbs)
Max. Actuation Speed
1m/s
Max. Actuation Frequency
2 cycle/s
Case Material
UL approved glass-filled polyester &
316L Stainless Steel
Actuator Material
Stainless steel
Contact Protection
IP67
Conduit Entry
3 x M20
Operating Temperature
-20°C to +80°C (-4°F to 176°F)
Humidity
95% RH
Mounting
SSS 4 x M5 Counterbored from Top or
4 x M5 from Underside with Nuts
DSS 6 x M5 Counterbored from Top or
6 x M5 from Underside with Nuts
Mechanical Life
100,000
Electrical Life
1,000,000
Weight
(SSSE) 1160g (2.6lbs)
(DSSE) 1700g (3.7lbs)
Colour
Red/Stainless
Max. Holding Force
2000N (450lbs)
Max. Releasable Load
100N (22.5lbs)
Max. Shear Force for Keys
15.1KN (3398lbs)
Max. Torque to Key
14Nm (124lb•in)
Note: The safety contacts of the Guardmaster switches are described as normally
closed (N/C), i.e. with the guard closed, actuator in place (where relevant)
and the machine able to be started.
The Prosafe Advantage
Stainless steel
construction.
5-26
Prosafe Trapped Key Interlock Switches
Slamlock Electrical
Product Selection
Contacts
Type
Key Condition
Key Trapped to
Release Actuator
Single Key
Key Free to
Release Actuator
2 N.C. + 1 N.O.
Break Before Make
Primary Key Trapped,
Secondary Key Free to
Release Actuator
Dual Key
Both Keys Free to
Release Actuator
Actuator
Standard
Flexible
Flat
Standard
Flexible
Flat
Standard
Flexible
Flat
Standard
Flexible
Flat
Catalogue Number
440T-MSSSE10➊
440T-MSSSE11➊
440T-MSSSE12➊
440T-MSSSE20➊
440T-MSSSE22➊
440T-MSSSE23➊
440T-MDSSE10➊➋
440T-MDSSE11➊➋
440T-MDSSE12➊➋
440T-MDSSE20➊➊
440T-MDSSE22➊➊
440T-MDSSE23➊➊
➊ Substitute the desired primary code for this symbol (key not included). See page 5-6 for code selection.
➋ Substitute the desired secondary code for this symbol (key included). See page 5-6 for code selection.
5-27
Prosafe Trapped Key Interlock Switches
Slamlock Electrical
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
Single Key Slamlock
3.5 (0.13)
38.3 (1.5)
11 21
48
(1.88)
Auxiliary Contacts
Safety Contacts
33
20.8
(0.81)
40
(1.57)
12 22
34
43.6 (1.71)
4 x M5
64.1 (2.52)
Top Entry
Front Entry
5.5
(0.21)
34
(1.33)
5
(0.19)
M20
20.8
(0.81)
4
(0.15)
3.5
(0.13)
Double Key Slamlock
38.3 (1.5)
93 (3.66)
Bottom Entry
Auxiliary Contacts
Safety Contacts
57.7 (2.27)
11 21
48
(1.88)
33
20.8
(0.81)
40
(1.57)
12 22
34
43.6 (1.71)
Top Entry
64.1 (2.52)
6 x M5
240 (9.44)
Key - Trapped
Key - Free
Front Entry
5.5
(0.21)
34
(1.33)
5
(0.19)
20.8
(0.81)
M20
4
Actuator (0.15)
Trapped
Bottom Entry
The Prosafe Advantage
Stainless steel
construction.
5-28
Prosafe Trapped Key Interlock Switches
Slamlock Electrical
Accessories
Description
Approximate Dimensions—mm (inches)
52 (2.04)
40 (1.57)
Replacement
Standard Actuator
18 (0.7)
4
(0.15)
Catalogue Number
3.5 (0.13)
M5 CSK
36
(1.41)
440G-A27011
14.5
(0.57)
57 (2.24)
25 (0.98)
36
(1.41)
Replacement
Flat Actuator
18 (0.7)
440K-A11112
31 (1.22)
40 (1.57)
52 (2.04)
3.5
(0.13)
2 Holes,
5.5 Thru
Replacement
Flexible Actuator
19
(0.74)
13
(0.51)
51 (2.0)
Replacement Keys
Replacement Code Barrel
Replacement Dust Cap
18
(0.7)
440G-A27143
8
20
(0.78)
See page 5-33
See page 5-33
See page 5-33
2 Holes,
5.5 Slots
440T-AKEYE10⊗
440T-ASCBE14➊
440T-ASFC10⊗
➊ Substitute the desired primary code for this symbol (key not included). See page 5-6 for code selection.
⊗ Substitute the desired secondary code for this symbol (key included). See page 5-6 for code selection.
Typical Applications
Actuator out, key trapped, safety
contacts open, auxiliary contact closed.
Key
Contacts Housing
Actuator
Locking force = 2000N (450lbs)
5-29