ALLEN-BRADLEY 440T

Prosafe Trapped Key Interlock Switches
Solenoid Release Units
Specifications
Standards
EN292-1&2, EN1954-1, IEC/EN60204-1,
EN1088, IEC/EN60947-5-1, ISO138491, ISO12100-1&2, ISO14119, GS-ET-19,
AS4024.1
Cat. 1 per EN 954-1 (ISO 13849-1)
Suitable for Cat. 2, 3, and 4 systems
BG, cULus and CE marked for all
applicable directives
24V DC, 110V AC, 230V AC, 110V DC
Category
Approvals
Solenoid Voltage
Solenoid Power
Description
The solenoid release unit is used for electrical isolation of machinery
to enable safe access. It consists of a rotary power switch (RPS) and
a solenoid. The trapped key can be removed once an external signal
is given to its internal solenoid locking mechanism. An indicator
light on the SRU indicates when trapped key can be removed; that is,
when power is applied to the solenoid. The solenoid signal only
needs to be present when key removal is necessary. The solenoid is
rated for 100% duty cycle. Power to the solenoid can be removed
after the trapped key is removed.
Removing the trapped key causes the isolating power switch to
change state; the normally open contacts open and the normally
closed contacts (if applicable) will close.
DC Types
AC Types
Electrical Characteristics
Mounting
Max Shear Force to Key
Max Torque to Key
Material
Trapped Key Components
Face Plate
Optional Box
Cable
6.5W continuous
6VA continuous
See rotary power switches
Any position
15.1kN (3398lbs)
14Nm (124lb•in)
316L Stainless Steel
316L Stainless Steel
ABS Plastic
0.75sq. mm2 (18AWG) 2-wire PVC
jacket QD
0°C to +40°C (+32°F to +104°F)
95% RH
Operating Temperature
Humidity
Environmental
With Optional Plastic IP65 (NEMA 13)
Enclosure
Electrical Life
>100,000
Mechanical Life
100,000
The trapped key can then be used in the next sequence of the
operation.
Features
•
•
•
•
•
•
•
•
•
•
•
Direct drive operation—positively opens contacts
Integral solenoid monitoring
Key trapped until release signal is applied
IP 65 enclosure or panel mounted versions
LED or NEON “key free” indication
316L stainless steel construction
24V DC, 110V AC/DC or 230V AC solenoid options
Weatherproof stainless steel dust cap as standard
UL and CSA approval on switches
Single or multiple key units available (contact factory)
Replaceable code barrel assembly
The Prosafe Advantage
Stainless steel
construction.
5-12
Prosafe Trapped Key Interlock Switches
Solenoid Release Units
Product Selection
Solenoid Voltage
Contacts
2 N.O. & 2 N.C.
24V DC
Current
32A
2 N.O. & 2 N.C.
20A
4 N.O.
32A
2 N.O. & 2 N.C.
230V AC
20A
4 N.O.
32A
2 N.O. & 2 N.C.
4 N.O.
3 N.O. & 3 N.C.
110V DC
440T-MSRUE11➊
440T-MSRUE10➊
440T-MSRUE12➊
440T-MSRUE22➊
440T-MSRUE20➊
440T-MSRUE23➊
440T-MSRUE33➊
440T-MSRUE30➊
440T-MSRUE34➊
440T-MSRUE44➊
440T-MSRUE40➊
440T-MSRUE46➊
20A
4 N.O.
110V AC
Catalogue Number
20A
➊ Substitute the desired primary code for this symbol (key not included). See page 5-6 for code selection.
Accessories
Description
Replacement Key
Replacement Code Barrel
Replacement Dust Cap
Additional Information
Catalogue Number
440T-AKEYE10⊗
440T-ASCBE14➊
440T-ASFC10⊗
440T-AIPB10
440T-AIPB22
See page 5-33
For use with 20A units
For use with 32A units
Optional IP65 Plastic Enclosure
➊ Substitute the desired primary code for this symbol (key not included). See page 5-6 for code selection.
⊗ Substitute the desired code for this symbol. See page 5-6 for code selection.
Approximate Dimensions—mm (inches) Typical Wiring Diagram
90 (3.54)
Trapped Key
(not included)
Solenoid
Status
70
Indicator (2.76)
Lamp
150 (5.91)
70
(2.76)
90 (3.54)
82 (3.23)
R4 (0.16)
Max
Panel
Cutout
MC MC
Gnd
132 (5.20)
6 Holes 4.5
(0.18) Dia
120 (4.72)
160 (6.30)
Terminal Block
Solenoid Status
Monitor Switch.
Contacts Break
When Solenoid
Retracted.
+
Dimensions are not intended to be used for installation purposes.
100 (3.93)
Optional Enclosure
440T-AIPB10
Optional
Enclosure
440T-AIPB22
300 (11.81)
230 (9.06)
110 (4.33)
5-13