PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET
JANUARY 2007
GENERAL DESCRIPTION
The XRT86SH328 is an integrated VT/TU Mapper
with 28 port T1/E1 Line Interface Units.
The
XRT86SH328
contains
integrated
DS1/E1/J1
Framers for performance monitoring.
The XRT86SH328 processes the Section, Line and
Path overhead in the SONET/SDH data-stream. The
processing of path overhead bytes within the STS-1s
or TUG-3s include 64 bytes (of buffer) for storing the
(Section Trace and Path Trace) messages. Path
Overhead bytes can be accessed either by on-chip
registers or a Serial Output Port.
Each of the 28 T1 or E1 Channels use an internal DeSynchronizer circuit with an internal pointer leak
algorithm. This removes the jitter due to mapping and
pointer adjustments from the T1 or E1 signals that are
de-mapped from the incoming SONET/SDH datastream. These De-Synchronizer circuits do not need
any external clock references for its operation.
The Transmit Blocks permit flexible insertion of TOH
and POH bytes via both Hardware and Software
control.
The Receive Blocks receive a SONET STS-1 signals
or an SDH STM-1 signal and performs the necessary
Transport and Path Overhead Processing.
A PRBS Pattern Generator and Receiver is
implemented within each of the 28 T1/E1 channels in
order to implement and measure Bit-Error
performance.
A general purpose Microprocessor Interface is
included for control, configuration and monitoring.
FEATURES
• Provides
mapping of up to 28 T1 streams as
Asynchronous VT1.5 into an STS-1 SPE or TU-11
tributary unit into an STM-1/VC-3 or TUG-3 from STM-1/
VC-4
• Supports
28 T1 streams M13 multiplexed into a serial
DS3
• Supports
21 E1 streams M13 multiplexed into a serial
DS3 (compliant with ITU-T G.747)
• 28 T1 Streams M13 Multiplexed into a DS3 and DS3 is
asynchronously mapped into STS-1.
• 21 E1 Streams M13 Multiplexed into a DS3 (ITU-T G.747)
REV. P1.0.6
• Supports
21 E1 mapped as Asynchronous VT2 into an
STS-1 SPE or TU-12 tributary units into STM-1/VC-3 or
TUG-3 from a STM-1/VC-4.
• Supports TU cross-mapping function TU-12/VC-11/T1.
• Supports mixed mapping of VT-G/VT1.5 and VT-G/VT2.
• Supports mixed mapping of TUG-2/TU-11 and TUG-2/
TU-12
• 28
VT1.5/TU-11 or 21 VT-2/TU-12 tributaries can be
passed as transparent between SONET/SDH Telecom
Bus on the line side and Clock and Data on the system
side.
• Supports Unframed T1/E1 signals
• Supports DS1/E1 Performance Monitoring in both Egress
and Ingress direction
• VC-11/VC-12 Tandem Connection Monitoring support
• Complies with the Category I Intrinsic Jitter
Requirements for DS1 signals being de-mapped from
SONET, per Telcordia GR-253-CORE
• Complies
with the "Mapping Jitter Generation
Specification" for DS1 and E1 signals being de-mapped
from SDH, per ITU-T G.783
• Complies
with the "Combined Jitter Generation
Specification" for DS1 and E1 signals being de-mapped
from SDH, per ITU-T G.783
• Line and Facility Loop-backs
• Each of the 28 T1/E1 Channels
includes a PRBS
Generator and Receiver.
• Each
of the 28 VT-Mapper blocks are capable of
generating BIP-2 and REI errors upon software
command (for diagnostic purposes).
• ·The Transmit and Receive DS3 Framer blocks support
both the M13(M23) and the C-bit Parity Framing formats.
• Integrated 28 T1/E1/J1 Short-Haul Line Interface Units
• IEEE 1149.1 Standard Boundary Scan
• Low Power: 1.8V Power Supply for Core Logic; 3.3V
Power Supply for I/O
• General Purpose Microprocessor Interface
APPLICATIONS
• Channelized and Unchannelized DS3 applications
• T1/E1 Terminals
• SONET/SDH ADM
and DS3 is asynchronously mapped into STS-1.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
FIGURE 1. BLOCK DIAGRAM OF THE XRT86SH328
ST
S-1/
STS-1/
ST
S-3
STS-3
Telecom
T elecom
BBus
us
Interface
Interface
TTransm
ransmitit
ST
STS-1/3
S-1/3
TTOOHH
Processor
Processor
BBlock
lock
TTransm
ransmitit
ST
S-1 PO
STS-1
POHH
Processor
Processor
BBlock
lock
VVT/T
T /TUU
MMapper
apper
BBlock
lock
Ingress
D irection
T ransm it
D S1/E 1
Fram er
Block
Ingress
D irection
R eceive
D S1/E 1
Fram er
B lock
R eceive
D S1/E 1
LIU
B lock
D S1/E 1 C hannel 0
From D S1/E1 C hannels 1 - 27
From DS2 C hannels 1 - 6
DDS3/
S3/
ST
S-1
STS-1
LLIU
IU
Interface
Interface
TTransm
ransm itit
DDS3
S3
Fram
Framerer
BBlock
lock
MM23
23
MMUUXX
BBlock
lock
RReceive
eceive
DDS3
S3
Fram
Framerer
BBlock
lock
MM23
23
DDe-M
e-MUUXX
BBlock
lock
M 12
M UX
B lock
From D S1/E 1 C hannels 1 - 3
D S2 C hannel 0
M 12
D e-M U X
B lock
To D S1/E 1 C hannels 1 - 3
D S2 C hannel 0
To D S1/E 1
C hannels 1 - 27
RReceive
eceive
ST
STS-1/3
S-1/3
TTOOHH
Processor
Processor
BBlock
lock
RReceive
eceive
ST
STS-1
S-1PO
POHH
Processor
Processor
BBlock
lock
To D S2 C hannels 1 - 6
VT /T U
D e-M apper
B lock
D S1/E1
Jitter
A tten
B lock
E gress
D irection
R eceive
D S1/E 1
Fram er
B lock
E gress
D irection
T ransm it
D S1/E 1
Fram er
B lock
Transm it
D S1/E 1
L IU
B lock
D S1/E 1 C hannel 0
TABLE 1: ORDERING INFORMATION
PRODUCT NUMBER
PACKAGE TYPE
OPERATING TEMPERATURE RANGE
XRT86SH328IB
568 Ball BGA
-40°C to +85°C
2
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
FIGURE 2. PIN OUT OF THE XRT86SH328 (BOTTOM VIEW)
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
T
U
V
W
Y
AA
AB
AC
AD
AE
AF
AG
AH
AJ
AK
3
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE OF CONTENTS
GENERAL DESCRIPTION ................................................................................................ 1
FEATURES ................................................................................................................................................. 1
APPLICATIONS .......................................................................................................................................... 1
FIGURE 1. BLOCK DIAGRAM OF THE XRT86SH328 .......................................................................................................................... 2
TABLE 1: ORDERING INFORMATION ................................................................................................................................................... 2
FIGURE 2. PIN OUT OF THE XRT86SH328 (BOTTOM VIEW) ............................................................................................................... 3
TABLE OF CONTENTS ............................................................................................................
I
1.0 REGISTER MAP & DESCRIPTION FOR THE XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH
DS3 MUX AND VT-MAPPER IC - SONET APPLICATIONS................................................................... 4
1.1 REGISTER MAP OF THE XRT86SH328 ............................................................................................................. 4
TABLE 2: OPERATION CONTROL REGISTERS ..................................................................................................................................... 4
TABLE 3: LIU COMMON CONTROL REGISTERS .................................................................................................................................. 5
TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ........................................................................................... 6
TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ......................................................................................... 10
TABLE 6: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER ......................................................... 12
TABLE 7: RECEIVE STS-1/STS-3 PATH - RECEIVE PATH TRACE MESSAGE BUFFER ........................................................................ 12
TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ................................................ 12
TABLE 9: RECEIVE TU-3 POH PROCESSOR BLOCK - RECEIVE PATH TRACE MESSAGE BUFFER (SDH/TUG-3 APPLICATIONS ONLY) 15
TABLE 10: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ..................................................................................... 15
TABLE 11: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ..................................................................................... 17
TABLE 12: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER .................................... 18
TABLE 13: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ................................... 18
TABLE 14: TRANSMIT TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ............................................ 19
TABLE 15: TRANSMIT TU-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ................................................. 20
TABLE 16: VT MAPPER CONTROL REGISTERS ................................................................................................................................ 20
TABLE 17: DS3 MAPPER CONTROL REGISTERS .............................................................................................................................. 21
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS .......................................................................................................... 22
TABLE 19: T1/E1 LIU CHANNEL CONTROL REGISTERS (WHERE N RANGES FROM 0X01 TO 0X1D) ................................................... 27
TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................... 28
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ...................................... 30
TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................... 37
TABLE 23: T1/E1 PERFORMANCE MONITOR REGISTER (WHERE N RANGES VALUE FROM 0X01 TO 0X38) .......................................... 39
TABLE 24: T1/E1 FRAMER BLOCK INTERRUPT REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................. 39
TABLE 25: VT MAPPER REGISTER (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................... 41
2.0 REGISTER DESCRIPTIONS.................................................................................................................. 42
TABLE 26: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000) ................................................................................... 42
2.1 OPERATION CONTROL REGISTERS.............................................................................................................. 43
TABLE 27: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000) ................................................................................... 43
TABLE 28: OPERATION CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0001) ................................................................................... 44
TABLE 29: OPERATION CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0003) ................................................................................... 45
TABLE 30: DEVICE ID VALUE REGISTER - BYTE 3 (ADDRESS = 0X0004) ......................................................................................... 45
TABLE 31: REVISION NUMBER VALUE REGISTER - BYTE 2 (ADDRESS = 0X0005) ............................................................................. 46
TABLE 32: OPERATION INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X000B) .................................................................... 46
TABLE 33: OPERATION INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X000F) .................................................................... 46
TABLE 34: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS = 0X0012) ......................................................... 47
TABLE 35: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0013) ......................................................... 48
TABLE 36: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS = 0X0016) ......................................................... 48
TABLE 37: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0017) ......................................................... 50
TABLE 38: MODE CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001B) ........................................................................................... 51
TABLE 39: LOOP-BACK CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001F) ................................................................................... 51
TABLE 40: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0034) ........................................................ 52
TABLE 41: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0035) ........................................................ 52
TABLE 42: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036) ............................................. 53
TABLE 43: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036) ............................................. 55
TABLE 44: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0037) ............................................. 57
TABLE 45: OPERATION BLOCK - INTERFACE CONTROL REGISTER (ADDRESS = 0X003C) .................................................................. 59
TABLE 46: OPERATION GENERAL PURPOSE INPUT/OUTPUT REGISTER - BYTE 0 (ADDRESS = 0X0047) ............................................ 59
TABLE 47: OPERATION GENERAL PURPOSE INPUT/OUTPUT DIRECTION REGISTER 0 (ADDRESS = 0X004B) ...................................... 60
TABLE 48: OPERATION I/O CONTROL REGISTER (ADDRESS = 0X004F) .......................................................................................... 60
TABLE 49: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0050) .......... 61
TABLE 50: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0051) .......... 62
TABLE 51: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0052) .......... 62
I
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 52: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0053) .......... 63
TABLE 53: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0054) ....... 63
TABLE 54: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0055) ....... 63
TABLE 55: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0056) ....... 64
TABLE 56: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0057) ....... 64
TABLE 57: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0058) ................................. 65
TABLE 58: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0059) ................................ 65
TABLE 59: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005A) ................................ 65
TABLE 60: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005B) ................................ 66
TABLE 61: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005C) ................................. 66
TABLE 62: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005D) ................................ 66
TABLE 63: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005E) ................................. 67
TABLE 64: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005F) ................................ 67
2.2 LIU COMMON CONTROL REGISTERS ........................................................................................................... 67
TABLE 65: LIU COMMON CONTROL REGISTER 0 (ADDRESS = 0X0100) ........................................................................................... 67
TABLE 66: LIU COMMON CONTROL REGISTER 1 (ADDRESS = 0X0101) ........................................................................................... 68
TABLE 67: LIU COMMON CONTROL REGISTER 2 (ADDRESS = 0X0102) ........................................................................................... 69
TABLE 68: LIU COMMON CONTROL REGISTER 3 (ADDRESS = 0X0103) ........................................................................................... 69
TABLE 69: LIU COMMON CONTROL REGISTER 4 (ADDRESS = 0X0104) .......................................................................................... 70
TABLE 70: LIU COMMON CONTROL REGISTER 5 (ADDRESS = 0X0105) ........................................................................................... 70
TABLE 71: LIU COMMON CONTROL REGISTER 6 (ADDRESS = 0X0106) ........................................................................................... 70
2.3 RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ................................................................. 71
FIGURE 3. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS-1/STS-3 TOH PROCESSOR
BLOCK HIGHLIGHTED ...................................................................................................................................................... 71
TABLE 72: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0202) .............................. 71
TABLE 73: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0203) ............................. 72
TABLE 74: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0206) ................................. 73
TABLE 75: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0207) ............................... 74
TABLE 76: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0209) ................ 76
TABLE 77: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X020A) ............... 77
TABLE 78: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION= 0X020B) ............... 79
TABLE 79: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 2 (ADDRESS LOCATION= 0X020D) ............... 80
TABLE 80: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X020E) ............... 81
TABLE 81: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION= 0X020F) ............... 83
TABLE 82: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0210) ...... 84
TABLE 83: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0211) ...... 84
TABLE 84: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0212) ...... 85
TABLE 85: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0213) ...... 85
TABLE 86: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0214) ...... 86
TABLE 87: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0215) ...... 86
TABLE 88: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0216) ...... 86
TABLE 89: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0217) ...... 87
TABLE 90: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION = 0X0218) .......... 87
TABLE 91: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0219) ........... 88
TABLE 92: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X021A) ........... 88
TABLE 93: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X021B) ........... 88
TABLE 94: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X021F) ................ 89
TABLE 95: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0223) ................. 89
TABLE 96: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0227) ................. 89
TABLE 97: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE IN-SYNC THRESHOLD REGISTER (ADDRESS = 0X022B) .......................... 90
TABLE 98: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - MSB (ADDRESS LOCATION= 0X022E) ......................... 90
TABLE 99: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - LSB (ADDRESS LOCATION= 0X022F) .......................... 90
TABLE 100: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X0231) 90
TABLE 101: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X0232) 91
TABLE 102: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X0233) 91
TABLE 103: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0236) ........... 92
TABLE 104: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X0237) ........... 92
TABLE 105: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X023A) ...... 92
TABLE 106: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X023B) ...... 93
TABLE 107: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X023D) 93
TABLE 108: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X023E) 94
TABLE 109: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X023F) 94
TABLE 110: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0242) ........... 95
TABLE 111: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X0243) ........... 95
TABLE 112: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0246) ...... 95
TABLE 113: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0247) ...... 96
II
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 114: RECEIVE STS-1/STS-3 TRANSPORT - FORCE SEF DEFECT CONDITION REGISTER (ADDRESS LOCATION= 0X024B) ...... 96
TABLE 115: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS LOCATION=
0X024F) ....................................................................................................................................................................... 96
TABLE 116: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 1 (ADDRESS LOCATION= 0X0252) 97
TABLE 117: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 0 (ADDRESS LOCATION= 0X0253) 98
TABLE 118: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 1 (ADDRESS LOCATION= 0X0256) 98
TABLE 119: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 0 (ADDRESS LOCATION= 0X0257) 99
TABLE 120: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X0259) 99
TABLE 121: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X025A) 99
TABLE 122: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X025B)
100
TABLE 123: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X025D)
100
TABLE 124: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X025E) .
101
TABLE 125: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X025F) 101
TABLE 126: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X0263) ...................... 102
TABLE 127: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS (IN DOWNSTREAM T1/E1S) CONTROL REGISTER (ADDRESS LOCATION=
0X026B) ..................................................................................................................................................................... 104
TABLE 128: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X026E) 105
TABLE 129: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X026F) 105
2.4 RECEIVE STS-1 POH PROCESSOR BLOCK REGISTERS ......................................................................... 105
FIGURE 4. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS-1 POH PROCESSOR BLOCK
HIGHLIGHTED ............................................................................................................................................................... 106
TABLE 130: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0281) ............................................... 106
TABLE 131: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0283) ................................ 107
TABLE 132: RECEIVE STS-1 PATH - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0286) .............................................. 108
TABLE 133: RECEIVE STS-1 PATH - SONET RECEIVE POH STATUS - BYTE 0 (ADDRESS LOCATION= 0X0287) ............................ 108
TABLE 134: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 2 (ADDRESS LOCATION= 0X0289) .......... 110
TABLE 135: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 1 (ADDRESS LOCATION= 0X028A) .......... 111
TABLE 136: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 0 (ADDRESS LOCATION= 0X028B) .......... 113
TABLE 137: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 2 (ADDRESS LOCATION = 0X028D) ......... 115
TABLE 138: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 1 (ADDRESS LOCATION= 0X028E) .......... 116
TABLE 139: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 0 (ADDRESS LOCATION= 0X028F) .......... 118
TABLE 140: RECEIVE STS-1 PATH - SONET RECEIVE RDI-P REGISTER (ADDRESS LOCATION= 0X0293) ..................................... 119
TABLE 141: RECEIVE STS-1 PATH - RECEIVED PATH LABEL VALUE (ADDRESS LOCATION= 0X0296) ............................................. 120
TABLE 142: RECEIVE STS-1 PATH - EXPECTED PATH LABEL VALUE (ADDRESS LOCATION= 0X0297) ............................................ 120
TABLE 143: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0298) ...................... 120
TABLE 144: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0299) ...................... 121
TABLE 145: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029A) ...................... 121
TABLE 146: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029B) ...................... 121
TABLE 147: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X029C) ........................... 122
TABLE 148: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X029D) ........................... 122
TABLE 149: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029E) ........................... 122
TABLE 150: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029F) ............................ 123
TABLE 151: RECEIVE STS-1 PATH - RECEIVE PATH TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS LOCATION= 0X02A3) 123
TABLE 152: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 1 (ADDRESS LOCATION= 0X02A6) .................................................... 124
TABLE 153: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 0 (ADDRESS LOCATION= 0X02A7) .................................................... 125
TABLE 154: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE VALUE REGISTER (ADDRESS = 0X02B9) ................................ 125
TABLE 155: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE CONTROL REGISTER (ADDRESS = 0X02BA) ........................... 125
TABLE 156: RECEIVE STS-1 PATH - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X02BB) ......................................... 126
TABLE 157: RECEIVE STS-1 PATH - SONET RECEIVE AUTO ALARM REGISTER - BYTE 0 (ADDRESS LOCATION= 0X02C3) ............ 128
TABLE 158: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS = 0X02C4) 129
TABLE 159: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS = 0X02C5) 129
TABLE 160: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS = 0X02C6) 130
TABLE 161: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS = 0X02C7) 130
TABLE 162: RECEIVE STS-1 PATH - RECEIVE J1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D3) ................................ 130
TABLE 163: RECEIVE STS-1 PATH - RECEIVE B3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D7) ............................... 130
TABLE 164: RECEIVE STS-1 PATH - RECEIVE C2 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DB) .............................. 131
TABLE 165: RECEIVE STS-1 PATH - RECEIVE G1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DF) .............................. 131
TABLE 166: RECEIVE STS-1 PATH - RECEIVE F2 BYTE CAPTURE REGISTER (ADDRESS LOCATION=0X02E3) ................................ 131
TABLE 167: RECEIVE STS-1 PATH - RECEIVE H4 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02E7) ............................... 131
TABLE 168: RECEIVE STS-1 PATH - RECEIVE Z3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EB) ............................... 132
TABLE 169: RECEIVE STS-1 PATH - RECEIVE Z4 (K3) BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EF) ....................... 132
TABLE 170: RECEIVE STS-1 PATH - RECEIVE Z5 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02F3) ................................ 132
2.5 RECEIVE TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
III
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
133
FIGURE 5. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE RECEIVE TUG-3 MAPPER/VC-4
POH PROCESSOR BLOCK "HIGHLIGHTED" ..................................................................................................................... 133
2.6 TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ............................................................ 133
FIGURE 6. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED ............................................................................................................................................ 134
TABLE 171: TRANSMIT STS-1/STS-3 TRANSPORT- TRANSMIT CONTROL REGISTER - BYTE 3 (ADDRESS LOCATION = 0X0700) ...... 134
TABLE 172: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION = 0X0701) ..... 135
TABLE 173: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0702) ...... 135
TABLE 174: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0703) ...... 136
TABLE 175: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A1 BYTE ERROR REGISTER (ADDRESS LOCATION = 0X0717) ......... 138
TABLE 176: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A2 BYTE ERROR REGISTER (ADDRESS LOCATION = 0X071F) ......... 138
TABLE 177: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B1 BYTE ERROR MASK REGISTER (ADDRESS LOCATION = 0X0723) 138
TABLE 178: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BYTE ERROR MASK REGISTER (ADDRESS LOCATION = 0X0727) 139
TABLE 179: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BIT ERROR MASK REGISTER (ADDRESS LOCATION= 0X072B) ... 139
TABLE 180: TRANSMIT STS-1/STS-3 TRANSPORT - K2 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X072E) ............ 140
TABLE 181: TRANSMIT STS-1/STS-3 TRANSPORT - K1 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X072F) ............ 140
TABLE 182: TRANSMIT STS-1/STS-3 TRANSPORT - RDI-L CONTROL REGISTER (ADDRESS LOCATION= 0X0733) .......................... 140
TABLE 183: TRANSMIT STS-1/STS-3 TRANSPORT - M0M1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0737) ..................... 141
TABLE 184: TRANSMIT STS-1/STS-3 TRANSPORT - S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073B) .......................... 141
TABLE 185: TRANSMIT STS-1/STS-3 TRANSPORT - F1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073F) .......................... 142
TABLE 186: TRANSMIT STS-1/STS-3 TRANSPORT - E1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0743) .......................... 142
TABLE 187: TRANSMIT STS-1/STS-3 TRANSPORT - E2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0747) .......................... 142
TABLE 188: TRANSMIT STS-1/STS-3 TRANSPORT - J0 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X074B) ........................... 143
TABLE 189: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMITTER J0 BYTE CONTROL REGISTER (ADDRESS LOCATION= 0X074F) . 143
2.7 TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ............................................................ 145
FIGURE 7. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK HIGHLIGHTED ............................................................................................................................................ 145
TABLE 190: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION = 0X0781) ............... 145
TABLE 191: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0782) ............... 146
TABLE 192: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0783) ................ 147
TABLE 193: TRANSMIT STS-1/STS-3 PATH - TRANSMITTER J1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0793) ................ 148
TABLE 194: TRANSMIT STS-1/STS-3 PATH - TRANSMIT B3 BYTE ERROR MASK REGISTER (ADDRESS LOCATION= 0X0797) .......... 148
TABLE 195: TRANSMIT STS-1/STS-3 PATH - TRANSMIT C2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079B) .................... 149
TABLE 196: TRANSMIT STS-1/STS-3 PATH - TRANSMIT G1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079F) .................... 149
TABLE 197: TRANSMIT STS-1/STS-3 PATH - TRANSMIT F2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A3) ..................... 149
TABLE 198: TRANSMIT STS-1/STS-3 PATH - TRANSMIT H4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A7) .................... 150
TABLE 199: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z3 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07AB) .................... 150
TABLE 200: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0XN9AF) .................... 150
TABLE 201: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z5 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07B3) ..................... 151
TABLE 202: TRANSMIT STS-1/STS-3 PATH - TRANSMIT PATH CONTROL REGISTER (ADDRESS LOCATION= 0X07B7) ..................... 151
TABLE 203: TRANSMIT STS-1/STS-3 PATH - SONET PATH J1 CONTROL REGISTER (ADDRESS LOCATION= 0X07BB) .................. 153
TABLE 204: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H1 POINTER REGISTER (ADDRESS LOCATION= 0X07BF) ........ 153
TABLE 205: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H2 POINTER REGISTER (ADDRESS LOCATION= 0X07C3) ........ 154
TABLE 206: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07C6)
154
TABLE 207: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07C7)
154
TABLE 208: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION= 0X07C9) ..................... 155
TABLE 209: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07CA) ..................... 155
TABLE 210: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07CB) ..................... 156
TABLE 211: TRANSMIT STS-1/STS-3 PATH - SERIAL PORT CONTROL REGISTER (ADDRESS LOCATION= 0X07CF) ......................... 157
TABLE 212: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D0) ........................................................................................................................................................... 157
TABLE 213: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07D1) ........................................................................................................................................................... 158
TABLE 214: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION=
0X07D2) ..................................................................................................................................................................... 158
TABLE 215: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION=
0X07D3) ..................................................................................................................................................................... 158
2.8 TRANSMIT TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS
ONLY)............................................................................................................................................................ 158
FIGURE 8. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT TUG-3 MAPPER/VC4 POH PROCESSOR BLOCK "HIGHLIGHTED" .................................................................................................................. 159
2.9 GLOBAL VT MAPPER BLOCK CONTROL REGISTERS .............................................................................. 159
TABLE 216: GLOBAL CONTROL - VT-MAPPER BLOCK - VT MAPPER BLOCK CONTROL REGISTER (ADDRESS = 0X0C03) ................. 159
IV
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
FIGURE 9. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WITH THE VT-MAPPER SONET/SDH LOOP-BACK
PATH DEPICTED ........................................................................................................................................................... 161
TABLE 217: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0C0E) ......... 161
TABLE 218: GLOBAL VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0C0F) ........................... 162
TABLE 219: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 1 (ADDRESS = 0X0C12) ............... 163
TABLE 220: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 0 (ADDRESS = 0X0C13) ............... 165
TABLE 221: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - UPPER BYTE (ADDRESS = 0X0C16)
166
TABLE 222: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - LOWER BYTE (ADDRESS = 0X0C17)
167
TABLE 223: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1A) ................... 167
TABLE 224: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1B) ................... 168
TABLE 225: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1E) ..................... 170
TABLE 226: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1F) ..................... 171
2.10 DS3 MAPPER CONTROL REGISTERS........................................................................................................ 172
TABLE 227: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D02) .............................................. 172
TABLE 228: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D03) .............................................. 173
TABLE 229: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D06) .................................. 173
TABLE 230: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D07) .................................. 174
TABLE 231: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D0B) ................... 175
TABLE 232: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0D0E) ................... 176
TABLE 233: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 2 (ADDRESS = 0X0D21) ........................... 176
TABLE 234: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 1 (ADDRESS = 0X0D22) ........................... 177
TABLE 235: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D23) ........................... 177
TABLE 236: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0D26) .............. 177
TABLE 237: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0D27) .............. 177
2.11 DS3 FRAMER AND M13 MUX BLOCK REGISTERS ................................................................................... 177
FIGURE 10. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE FUNCTIONAL BLOCKS (WHICH ARE CONTROLLED/MONITORED VIA THE DS3 FRAMER AND M13 MUX BLOCK REGISTERS) HIGHLIGHTED. ..................................... 178
TABLE 238: DS3 FRAMER BLOCK OPERATING MODE REGISTER (ADDRESS = 0X0E00) ................................................................. 178
TABLE 239: DS3 FRAMER BLOCK - I/O CONTROL REGISTER (ADDRESS = 0X0E01) ...................................................................... 179
TABLE 240: DS3 FRAMER BLOCK - BLOCK INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E04) .................................................. 180
TABLE 241: DS3 FRAMER BLOCK - BLOCK INTERRUPT STATUS REGISTER (ADDRESS = 0X0E05) .................................................. 181
TABLE 242: DS3 FRAMER BLOCK - M23 CONFIGURATION REGISTER (ADDRESS = 0X0E07) .......................................................... 182
FIGURE 11. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN CONFIGURED TO OPERATE IN THE M13 LOCAL LOOP- BACK MODE .............................................................................................................. 183
TABLE 243: DS3 FRAMER BLOCK - M23 TRANSMIT DS2 AIS COMMAND REGISTER (ADDRESS = 0X0E08) .................................... 184
FIGURE 12. AN ILLUSTRATION OF THE XRT86SH328, WHENEVER THE M12 MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR TOWARDS BOTH THE M23 MUX AND THE TRANSMIT DS3 FRAMER BLOCK .......................................................... 184
TABLE 244: DS3 FRAMER BLOCK - M23 - DS2 LOOP-BACK REQUEST REGISTER (ADDRESS = 0X0E09) ........................................ 185
TABLE 245: DS3 FRAMER BLOCK - M23 LOOP-BACK ACTIVATION REGISTER (ADDRESS = 0X0E0A) .............................................. 186
FIGURE 13. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN DS2 CHANNEL HAS BEEN
CONFIGURED TO OPERATE IN THE REMOTE DS2 LOOP-BACK MODE .............................................................................. 186
TABLE 246: DS3 FRAMER BLOCK - M23 MUX FORCE RECEIVE DS2 AIS COMMAND REGISTERS (ADDRESS = 0X0E0B) ............... 187
FIGURE 14. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE M23 DE-MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR IN THE EGRESS DIRECTION OF DS2 CHANNEL 0 .................................. 188
TABLE 247: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER (ADDRESS = 0X0E0C) .................................................. 189
TABLE 248: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER # 2 (ADDRESS = 0X0E0E) ............................................. 189
TABLE 249: DS3 FRAMER BLOCK - RECEIVE DS3 CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E10) ............................ 190
TABLE 250: DS3 FRAMER BLOCK - RECEIVE DS3 STATUS REGISTER (ADDRESS = 0X0E11) ......................................................... 191
TABLE 251: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E12) ....................................... 192
TABLE 252: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT STATUS ........................................ REGISTER (ADDRESS = 0X0E13) 194
TABLE 253: DS3 FRAMER BLOCK - RECEIVE DS3 SYNC DETECT REGISTER (ADDRESS = 0X0E14) ............................................... 195
TABLE 254: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC REGISTER (ADDRESS = 0X0E16) .......................................................... 195
TABLE 255: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC INTERRUPT ENABLE/STATUS REGISTER (ADDRESS = 0X0E17) ............... 196
TABLE 256: DS3 FRAMER BLOCK - RECEIVE LAPD CONTROL REGISTER (ADDRESS = 0X0E18) .................................................... 197
TABLE 257: DS3 FRAMER BLOCK - RECEIVE DS3 LAPD STATUS REGISTER (ADDRESS = 0X0E19) .............................................. 198
TABLE 258: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E1A) .......................... 199
TABLE 259: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E1B) .......................... 200
TABLE 260: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E1C) ......................... 200
TABLE 261: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E1D) .......................... 200
TABLE 262: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E1E) .......................... 201
TABLE 263: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E1F) ........................... 201
TABLE 264: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 7 (ADDRESS = 0X0E20) ........................... 201
TABLE 265: DS3 FRAMER BLOCK - M12 DE-MUX FORCE DS1/E1 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E21) ...... 201
FIGURE 15. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN M12 DE-MUX BLOCK HAS
V
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BEEN CONFIGURED TO TRANSMIT THE DS1/E1 AIS INDICATOR (WITHIN A GIVEN DS1/E1 SIGNAL) IN THE EGRESS DIRECTION
202
TABLE 266: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E22) .............................................. 203
TABLE 267: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E23) .............................................. 203
TABLE 268: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E24) .............................................. 203
TABLE 269: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E25) .............................................. 204
TABLE 270: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E26) .............................................. 204
TABLE 271: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E27) .............................................. 204
TABLE 272: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 1 (ADDRESS = 0X0E28) ............................................................ 205
FIGURE 16. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN CONFIGURED TO OPERATE
IN THE M12 REMOTE LOOP-BACK MODE ...................................................................................................................... 205
TABLE 273: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 2 (ADDRESS = 0X0E29) ............................................................ 206
TABLE 274: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 3 (ADDRESS = 0X0E2A) ............................................................ 206
TABLE 275: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 4 (ADDRESS = 0X0E2B) ............................................................ 207
TABLE 276: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 5 (ADDRESS = 0X0E2C) ............................................................ 207
TABLE 277: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 6 (ADDRESS = 0X0E2D) ............................................................ 207
TABLE 278: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 7 (ADDRESS = 0X0E2E) ............................................................ 207
TABLE 279: DS3 FRAMER BLOCK - TRANSMIT DS3 CONFIGURATION REGISTER (ADDRESS = 0X0E30) .......................................... 208
TABLE 280: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E31) ............... 209
TABLE 281: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC REGISTER (ADDRESS = 0X0E32) ......................................................... 210
TABLE 282: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD CONFIGURATION REGISTER (ADDRESS = 0X0E33) ................................ 211
TABLE 283: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD STATUS/INTERRUPT REGISTER (ADDRESS = 0X0E34) ........................... 212
TABLE 284: DS3 FRAMER BLOCK - TRANSMIT DS3 M-BIT MASK REGISTER (ADDRESS = 0X0E35) ................................................ 212
TABLE 285: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTERS # 1 (ADDRESS = 0X0E36) ......................................... 213
TABLE 286: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 2 (ADDRESS = 0X0E37) ........................................... 214
TABLE 287: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 3 (ADDRESS = 0X0E38) ........................................... 215
TABLE 288: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 4 (ADDRESS = 0X0E39) ........................................... 215
TABLE 289: DS3 FRAMER BLOCK - M12 DS2 # 1 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3A) .............................. 216
TABLE 290: DS3 FRAMER BLOCK - M12 DS2 # 2 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3B) .............................. 217
TABLE 291: DS3 FRAMER BLOCK - M12 DS2 # 3 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3C) .............................. 218
TABLE 292: DS3 FRAMER BLOCK - M12 DS2 # 4 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3D) .............................. 218
TABLE 293: DS3 FRAMER BLOCK - M12 DS2 # 5 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3E) .............................. 218
TABLE 294: DS3 FRAMER BLOCK - M12 DS2 # 6 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3F) .............................. 219
TABLE 295: DS3 FRAMER BLOCK - M12 DS2 # 7 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E40) ............................... 219
TABLE 296: DS3 FRAMER BLOCK - TRANSMIT DS3 PATTERN REGISTER (ADDRESS = 0X0E4C) .................................................... 219
TABLE 297: DS3 FRAMER BLOCK - AUTO T1/E1 AIS UPON DS3 DEFECT CONDITION REGISTER (ADDRESS = 0X0E4D) ................ 220
TABLE 298: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E4E) ........ 221
TABLE 299: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E4F) ......... 222
TABLE 300: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E50) . 222
TABLE 301: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E51) .. 222
TABLE 302: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E52) ......................... 222
TABLE 303: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E53) .......................... 223
TABLE 304: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E54) .................................... 223
TABLE 305: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E55) ..................................... 223
TABLE 306: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E56) .................................... 224
TABLE 307: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E57) ..................................... 224
TABLE 308: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E58) ............................................. 224
TABLE 309: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E59) .............................................. 224
TABLE 310: DS3 FRAMER BLOCK - PMON DS2 # 1 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5A) ..................... 225
TABLE 311: DS3 FRAMER BLOCK - PMON DS2 # 2 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5B) ..................... 225
TABLE 312: DS3 FRAMER BLOCK - PMON DS2 # 3 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5C) ..................... 225
TABLE 313: DS3 FRAMER BLOCK - PMON DS2 # 4 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5D) ..................... 225
TABLE 314: DS3 FRAMER BLOCK - PMON DS2 # 5 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5E) ..................... 226
TABLE 315: DS3 FRAMER BLOCK - PMON DS2 # 6 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5F) ..................... 226
TABLE 316: DS3 FRAMER BLOCK - PMON DS2 # 7 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E60) ...................... 226
TABLE 317: DS3 FRAMER BLOCK - PMON G.747 # 1 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E61) ...................... 226
TABLE 318: DS3 FRAMER BLOCK - PMON G.747 # 2 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E62) ...................... 226
TABLE 319: DS3 FRAMER BLOCK - PMON G.747 # 3 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E63) ...................... 227
TABLE 320: DS3 FRAMER BLOCK - PMON G.747 # 4 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E64) ...................... 227
TABLE 321: DS3 FRAMER BLOCK - PMON G.747 # 5 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E65) ...................... 227
TABLE 322: DS3 FRAMER BLOCK - PMON G.747 # 6 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E66) ...................... 227
TABLE 323: DS3 FRAMER BLOCK - PMON G.747 # 7 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E67) ...................... 227
TABLE 324: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E68) ........................................ 228
TABLE 325: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E69) ......................................... 228
TABLE 326: DS3 FRAMER BLOCK - ONE SECOND ERROR STATUS REGISTER (ADDRESS = 0X0E6D) ............................................. 228
TABLE 327: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E6E) ........................... 229
VI
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 328: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E6F) ............................ 229
TABLE 329: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E70) .............. 229
TABLE 330: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E71) ............... 230
TABLE 331: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E72) ............ 230
TABLE 332: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E73) ............. 230
TABLE 333: DS3 FRAMER BLOCK - TRANSMIT LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E83) ............................................. 231
TABLE 334: DS3 FRAMER BLOCK - RECEIVE LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E84) ............................................... 231
TABLE 335: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E90) ..... 231
TABLE 336: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT STATUS REGISTER (ADDRESS = 0X0E91) ..... 232
TABLE 337: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST STATUS REGISTER (ADDRESS = 0X0E92) ....................... 233
TABLE 338: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 1 (ADDRESS = 0X0E93) ................. 234
TABLE 339: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 1 (ADDRESS = 0X0E94) ............................................. 235
TABLE 340: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 2 (ADDRESS = 0X0E95) ................. 235
TABLE 341: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 2 (ADDRESS = 0X0E96) ............................................. 236
TABLE 342: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 3 (ADDRESS = 0X0E97) ................. 236
TABLE 343: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 3 (ADDRESS = 0X0E98) ............................................. 236
TABLE 344: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 4 (ADDRESS = 0X0E99) ................. 237
TABLE 345: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 4 (ADDRESS = 0X0E9A) ............................................. 237
TABLE 346: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 5 (ADDRESS = 0X0E9B) ................. 237
TABLE 347: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 5 (ADDRESS = 0X0E9C) ............................................. 238
TABLE 348: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 6 (ADDRESS = 0X0E9D) ................ 238
TABLE 349: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 6 (ADDRESS = 0X0E9E) ............................................. 238
TABLE 350: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 7 (ADDRESS = 0X0E9F) ................. 239
TABLE 351: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 7 (ADDRESS = 0X0EA0) ............................................. 239
TABLE 352: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA1) ................................. 239
TABLE 353: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA2) ................................. 241
TABLE 354: DS3 FRAMER BLOCK - DS2 # 1 FRAMER STATUS REGISTER (ADDRESS = 0X0EA3) ................................................... 242
TABLE 355: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA4) ................................. 243
TABLE 356: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA5) ................................. 243
TABLE 357: DS3 FRAMER BLOCK - DS2 # 2 FRAMER STATUS REGISTER (ADDRESS = 0X0EA6) ................................................... 243
TABLE 358: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA7) ................................. 244
TABLE 359: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA8) ................................. 244
TABLE 360: DS3 FRAMER BLOCK - DS2 # 3 FRAMER STATUS REGISTER (ADDRESS = 0X0EA9) ................................................... 244
TABLE 361: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAA) ................................. 245
TABLE 362: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAB) ................................. 245
TABLE 363: DS3 FRAMER BLOCK - DS2 # 4 FRAMER STATUS REGISTER (ADDRESS = 0X0EAC) .................................................. 245
TABLE 364: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAD) ................................. 246
TABLE 365: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAE) ................................. 246
TABLE 366: DS3 FRAMER BLOCK - DS2 # 5 FRAMER STATUS REGISTER (ADDRESS = 0X0EAF) ................................................... 246
TABLE 367: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB0) ................................. 247
TABLE 368: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB1) ................................. 247
TABLE 369: DS3 FRAMER BLOCK - DS2 # 6 FRAMER STATUS REGISTER (ADDRESS = 0X0EB2) ................................................... 247
TABLE 370: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB3) ................................. 248
TABLE 371: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB4) ................................. 248
TABLE 372: DS3 FRAMER BLOCK - DS2 # 7 FRAMER STATUS REGISTER (ADDRESS = 0X0EB5) ................................................... 248
TABLE 373: DS3 FRAMER BLOCK - M13 DE-MUX REGISTER (ADDRESS = 0X0EB8) ..................................................................... 249
2.12 T1/E1 LIU CHANNEL CONTROL REGISTERS ............................................................................................ 249
TABLE 374: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN000) ..................................................................................... 249
TABLE 375: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN001) ...................................................................................... 250
TABLE 376: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN002) ...................................................................................... 251
TABLE 377: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN003) ...................................................................................... 252
TABLE 378: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN004) ...................................................................................... 253
TABLE 379: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN005) ...................................................................................... 253
TABLE 380: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN006) ...................................................................................... 254
TABLE 381: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN007) ...................................................................................... 255
TABLE 382: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN008) ...................................................................................... 256
TABLE 383: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN009) ...................................................................................... 256
TABLE 384: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00A) ...................................................................................... 256
TABLE 385: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00B) ...................................................................................... 257
TABLE 386: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00C) ...................................................................................... 257
TABLE 387: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00D) ...................................................................................... 257
TABLE 388: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00E) ...................................................................................... 258
TABLE 389: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00F) ...................................................................................... 258
TABLE 390: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN010) ...................................................................................... 258
TABLE 391: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN011) ...................................................................................... 259
2.13 DS1/E1 FRAMER BLOCK REGISTERS - DS1 APPLICATIONS ................................................................. 259
VII
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
FIGURE 17. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT/RECEIVE DS1/E1
FRAMER BLOCKS HIGHLIGHTED ..................................................................................................................................... 259
TABLE 392: MEMORY MAP - T1/E1 FRAMER BLOCK ..................................................................................................................... 260
FIGURE 18. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE WITH BOTH THE INGRESS AND EGRESS DIRECTION T1/E1 FRAMER BLOCKS (OF A GIVEN T1/E1 CHANNEL) HIGHLIGHTED .............................................................. 261
TABLE 393: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - VT-MAPPER (WITH T1/E1 FRAMING) MODE
APPLICATIONS ............................................................................................................................................................. 261
TABLE 394: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - M13 MUX (WITH T1/E1 FRAMING) MODE
APPLICATIONS ............................................................................................................................................................. 262
TABLE 395: T1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
263
TABLE 396: T1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN VALUE FROM 0X01 TO
0X38) ......................................................................................................................................................................... 264
TABLE 397: T1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
265
TABLE 398: T1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
266
TABLE 399: T1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN VALUE FROM 0X01 TO
0X38) ......................................................................................................................................................................... 268
TABLE 400: T1 FRAMER BLOCK - TRANSMIT DATA LINK SELECT REGISTER (ADDRESS = 0XN10A, WHERE N RANGES IN VALUE FROM 0X01
TO 0X38) .................................................................................................................................................................... 268
TABLE 401: T1 FRAMER BLOCK - FRAMING CONTROL REGISTER (ADDRESS = 0XN10B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
270
TABLE 402: T1 FRAMER BLOCK - RECEIVE SIGNALING & DATA LINK SELECT REGISTER (ADDRESS = 0XN10C, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38) .................................................................................................................................................. 270
TABLE 403: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 0 (ADDRESS = 0XN10D, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38) ............................................................................................................................................................ 272
TABLE 404: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 1 (ADDRESS = 0XN10E, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38) ............................................................................................................................................................ 272
TABLE 405: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 2 (ADDRESS = 0XN10F, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38) ............................................................................................................................................................ 272
TABLE 406: T1 FRAMER BLOCK - RECEIVE EXTRA-BITS REGISTER (ADDRESS = 0XN112, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
273
TABLE 407: T1 FRAMER BLOCK - DATA LINK CONTROL REGISTER (ADDRESS = 0XN113, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
273
TABLE 408: T1 FRAMER BLOCK - TRANSMIT DATA LINK CONTROL REGISTER (ADDRESS = 0XN114, WHERE N RANGES IN VALUE FROM 0X01
TO 0X38) .................................................................................................................................................................... 274
TABLE 409: T1 FRAMER BLOCK - RECEIVE DATA LINK CONTROL REGISTER (ADDRESS = 0XN115, WHERE N RANGES IN VALUE FROM 0X01
TO 0X38) .................................................................................................................................................................... 275
TABLE 410: T1 FRAMER BLOCK - CUSTOMER INSTALLATION ALARM GENERATION REGISTERS (ADDRESS = 0XN11C, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38) ........................................................................................................................................ 275
TABLE 411: T1 FRAMER BLOCK - DS1 TEST REGISTER - 2 (ADDRESS = 0XN121, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 276
TABLE 412: T1 FRAMER BLOCK - DS1 TEST REGISTER - 1 (ADDRESS = 0XN123, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 277
TABLE 413: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 0(ADDRESS = 0XN124, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38) ............................................................................................................................................................ 278
TABLE 414: T1 FRAMER BLOCK - TRANSMIT LOOP-BACK CODE REGISTER (ADDRESS = 0XN125, WHERE N RANGES IN VALUE FROM 0X01
TO 0X38) .................................................................................................................................................................... 279
TABLE 415: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 0 (ADDRESS = 0XN126, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................................... 280
TABLE 416: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 0 (ADDRESS = 0XN127, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X38) ................................................................................................................... 281
TABLE 417: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 1 (ADDRESS = 0XN12A, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38) .................................................................................................................................................. 281
TABLE 418: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 1 (ADDRESS = 0XN12B, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................................... 282
TABLE 419: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 1 (ADDRESS = 0XN12C, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X38) ................................................................................................................... 283
TABLE 420: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 2 (ADDRESS = 0XN12D, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38) .................................................................................................................................................. 284
TABLE 421: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 2 (ADDRESS = 0XN12E, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................................... 285
TABLE 422: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 2 (ADDRESS = 0XN12F, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X38) ................................................................................................................... 285
TABLE 423: T1 FRAMER BLOCK - TRANSMIT CHANNEL CONTROL REGISTER - T1 TIME SLOT # 0 (ADDRESS = 0XN300, WHERE N RANGES
IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................... 286
TABLE 424: T1 FRAMER BLOCK - LAPD BUFFER 0 CONTROL REGISTER (ADDRESS = 0XN600 - 0XN640, WHERE N RANGES IN VALUE FROM
VIII
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
0X01 TO 0X38) ............................................................................................................................................................ 287
TABLE 425: T1 FRAMER BLOCK - LAPD BUFFER 1 CONTROL REGISTER (ADDRESS = 0XN700 - 0XN740, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38) ............................................................................................................................................................ 287
TABLE 426: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER -CODE 0 (ADDRESS =
0XNB0A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 288
TABLE 427: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 0 (ADDRESS =
0XNB0B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 289
TABLE 428: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER - CODE 1 (ADDRESS =
0XNB14, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 290
TABLE 429: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 1 (ADDRESS = 0XNB15,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................... 291
TABLE 430: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER - CODE 2 (ADDRESS =
0XNB1A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 292
TABLE 431: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 2 (ADDRESS =
0XNB1B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 293
2.14 DS1/E1 FRAMER BLOCK REGISTERS - E1 APPLICATIONS ................................................................... 294
TABLE 432: E1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
294
TABLE 433: E1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN VALUE FROM 0X01 TO
0X38) .......................................................................................................................................................................... 295
TABLE 434: E1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
296
TABLE 435: E1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
298
TABLE 436: E1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN VALUE FROM 0X01 TO
0X38) .......................................................................................................................................................................... 299
2.15 CHANNEL CONTROL-VT MAPPER BLOCK REGISTERS.......................................................................... 300
FIGURE 19. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE VT-MAPPER BLOCK HIGHLIGHTED
301
TABLE 437: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION DS1/E1 INSERTION CONTROL REGISTER - 2 (ADDRESS =
0XND41) .................................................................................................................................................................... 301
TABLE 438: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL REGISTER - 1 (ADDRESS =
0XND42, WHERE N RANGES FROM 0X01 TO 0X1C) ...................................................................................................... 302
TABLE 439: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL REGISTER - 0 (ADDRESS =
0XND43 , WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 303
FIGURE 20. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WHENEVER THE VT-MAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) HAS BEEN CONFIGURED TO TRANSMIT THE AIS-V INDICATOR TOWARDS DOWN-STREAM CIRCUITRY
304
TABLE 440: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 3 (ADDRESS
= 0XND44, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 306
TABLE 441: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 2 (ADDRESS
= 0XND45, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 306
TABLE 442: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 1 (ADDRESS
= 0XND46, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 307
TABLE 443: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYT E 0 (ADDRESS
= 0XND47, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 307
FIGURE 21. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE VT-DE-MAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) OVERWRITES THE CONTENTS OF A DE-MAPPED DS1/E1 SIGNAL WITH THE DS1/E1 AIS PATTERN ........................................................................................................................................................................... 308
TABLE 444: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER - BYTE 1 (ADDRESS =
0XND4A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 310
TABLE 445: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER - BYTE 0 (ADDRESS =
0XND4B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 311
TABLE 446: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER - BYTE 1 (ADDRESS =
0XND4E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 311
TABLE 447: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER - BYTE 0 (ADDRESS =
0XND4F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 312
TABLE 448: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - RECEIVE APS REGISTER - BYTE 0 (ADDRESS = 0XND53,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 312
TABLE 449: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS REGISTER - BYTE 2 (ADDRESS = 0XND56,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 312
TABLE 450: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS/K4 REGISTER (ADDRESS = 0XND57, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X1C) ................................................................................................................... 313
TABLE 451: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - J2 BYTE STATUS REGISTER (ADDRESS = 0XND63, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X1C) ................................................................................................................... 314
TABLE 452: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER - BYTE 0 (ADDRESS =
IX
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
0XND64, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 314
TABLE 453: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER - BYTE 0 (ADDRESS =
0XND65, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 315
TABLE 454: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT STATUS REGISTER (ADDRESS = 0XND67, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................................................. 317
TABLE 455: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND68, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................................................. 318
TABLE 456: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND69,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 318
TABLE 457: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND6B,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 320
TABLE 458: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - VT-PATH TRACE BUFFER CONTROL REGISTER (ADDRESS
= 0XND71, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ................................................................................... 321
TABLE 459: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER - BYTE 1 (ADDRESS =
0XND72, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 322
TABLE 460: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER - BYTE 0 (ADDRESS =
0XND73, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 323
TABLE 461: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT J2 BYTE VALUE REGISTER (ADDRESS = 0XND76,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 324
TABLE 462: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT N2 BYTE VALUE REGISTER (ADDRESS = 0XND77,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 324
TABLE 463: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT VT-PATH TRACE MESSAGE CONTROL REGISTER
(ADDRESS = 0XND79, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................... 325
TABLE 464: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 3 (ADDRESS
= 0XND84, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 326
TABLE 465: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 2 (ADDRESS
= 0XND85, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 326
TABLE 466: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 1 (ADDRESS
= 0XND86, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 327
TABLE 467: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 0 (ADDRESS
= 0XND87, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 328
REVISIONS................................................................................................................................................ 329
X
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
1.0 REGISTER MAP & DESCRIPTION FOR THE XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU
WITH DS3 MUX AND VT-MAPPER IC - SONET APPLICATIONS
1.1
REGISTER MAP OF THE XRT86SH328
TABLE 2: OPERATION CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0000
Operation Control Register - Byte 3
R/W
0x00
0x0001
Operation Control Register - Byte 2
R/W
0x00
0x0002
Reserved
0x0003
Operation Control Register - Byte 0
R/W
0x00
0x0004
Device ID Register
R/O
0x50
0x0005
Revision ID Register
R/O
0x01
RUR
0x00
R/W
0x00
0x0006 - 0x000A Reserved
0x000B
Operation Interrupt Status Register - Byte 0
0x000C - 0x000E Reserved
0x000F
0x0010 - 0x0011
Operation Interrupt Enable Register - Byte 0
Reserved
0x0012
Operation Block - Interrupt Status Register - Byte 1
R/O
0x00
0x0013
Operation Block - Interrupt Status Register - Byte 0
R/O
0x00
0x0014 - 0x0015 Reserved
0x0016
Operation Block - Interrupt Enable Register - Byte 1
R/W
0x00
0x0017
Operation Block - Interrupt Enable Register - Byte 0
R/W
0x00
R/W
0x00
R/W
0x00
0x0018 - 0x001A Reserved
0x001B
Operation Block - Mode Control Register - Byte 0
0x001C - 0x001E Reserved
0x001F
Operation Block - Loop-back Control Register - Byte 0
0x0020 - 0x0033 Reserved
0x0034
Operation Block - Telecom Bus Control Register - Byte 3
R/W
0x00
0x0035
Operation Block - Telecom Bus Control Register - Byte 2
R/W
0x00
0x0036
Operation Block - Telecom Bus Control Register - Byte 1
R/W
0x00
0x0037
Operation Block - Telecom Bus Control Register - Byte 0
R/W
0x00
RUR & R/W
0x00
R/W
0x00
0x0038 - 0x003B Reserved
0x003C
Operation Block - Interface Control Register
0x003D - 0x0046 Reserved
0x0047
Operation Block - General Purpose Input/Output Register - Byte 0
4
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 2: OPERATION CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
RW
0x00
0x0048 - 0x004A Reserved
0x004B
Operation Block - General Purpose Input/Output Direction Register Byte 0
0x004C - 0x004E Reserved
0x004F
Operation Block - Operation I/O Control Register
R/W
0x00
0x0050
Operation Block - Channel Interrupt Indication Register - VT Slot[27:24]
R/O
0x00
0x0051
Operation Block - Channel Interrupt Indicator Register - VT Slot[23:16]
R/O
0x00
0x0052
Operation Block - Channel Interrupt Indicator Register - VT Slot[15:8]
R/O
0x00
0x0053
Operation Block - Channel Interrupt Indicator Register - VT Slot[7:0]
R/O
0x00
0x0054
Operation Block - Channel Interrupt Indicator Register - M13 Slot[27:24]
R/O
0x00
0x0055
Operation Block - Channel Interrupt Indicator Register - M13 Slot[23:16]
R/O
0x00
0x0056
Operation Block - Channel Interrupt Indicator Register - M13 Slot[15:8]
R/O
0x00
0x0057
Operation Block - Channel Interrupt Indicator Register - M13 Slot[7:0]
R/O
0x00
0x0058
Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU
Slot[27:24]
R/O
0x00
0x0059
Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU
Slot[23:16]
R/O
0x00
0x005A
Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU
Slot[15:8]
R/O
0x00
0x005B
Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU
Slot[7:0]
R/O
0x00
0x005C
Operation Block - Channel Interrupt Indicator Register - VT-Mapper
Slot[27:24]
R/O
0x00
0x005D
Operation Block - Channel Interrupt Indicator Register - VT-Mapper
Slot[23:16]
R/O
0x00
0x005E
Channel Interrupt Indication Register - VT-Mapper Slot[15:8]
R/O
0x00
0x005F
Channel Interrupt Indication Register - VT-Mapper Slot[7:0]
R/O
0x00
TYPE
DEFAULT
VALUE
0x0060 - 0x00FF Reserved
TABLE 3: LIU COMMON CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
0x0100
LIU Common Control Register - 0
R/W
0x00
0x0101
LIU Common Control Register - 1
R/W
0x00
0x0102
LIU Common Control Register - 2
R/W
0x00
5
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 3: LIU COMMON CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0103
LIU Common Control Register - Global Channel Interrupt Status Register Channels [6:0]
RUR
0x00
0x0104
LIU Common Control Register - Global Channel Interrupt Status Register Channels [13:7]
RUR
0x00
0x0105
LIU Common Control Register - Global Channel Interrupt Status Register Channels [20:14]
RUR
0x00
0x0106
LIU Common Control Register - Global Channel Interrupt Status Register Channels [27:21]
RUR
0x00
0x0107 - 0x01FF Reserved
TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
0x0200 - 0x0201
REGISTER NAME
TYPE
DEFAULT
VALUE
Reserved
0x0202
Receive STS-1/STS-3 Transport - Control Register - Byte 1
R/W
0x00
0x0203
Receive STS-1/STS-3 Transport - Control Register - Byte 0
R/W
0x00
Reserved
R/O
0x00
0x0206
Receive STS-1/STS-3 Transport - Status Register - Byte 1
R/O
0x00
0x0207
Receive STS-1/STS-3 Transport - Status Register - Byte 0
R/O
0x00
0x0208
Reserved
0x0209
Receive STS-1/STS-3 Transport - Interrupt Status Register - Byte 2
RUR
0x00
0x020A
Receive STS-1/STS-3 Transport - Interrupt Status Register - Byte 1
RUR
0x00
0x020B
Receive STS-1/STS-3 Transport - Interrupt Status Register - Byte 0
RUR
0x00
0x020C
Reserved
0x020D
Receive STS-1/STS-3 Transport - Interrupt Enable Register - Byte 2
R/W
0x00
0x020E
Receive STS-1/STS-3 Transport - Interrupt Enable Register - Byte 1
R/W
0x00
0x020F
Receive STS-1/STS-3 Transport - Interrupt Enable Register - Byte 0
R/W
0x00
0x0210
Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 3
RUR
0x00
0x0211
Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 2
RUR
0x00
0x0212
Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 1
RUR
0x00
0x0213
Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 0
RUR
0x00
0x0204 - 0x0205
6
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0214
Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 3
RUR
0x00
0x0215
Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 2
RUR
0x00
0x0216
Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 1
RUR
0x00
0x0217
Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 0
RUR
0x00
0x0218
Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 3
RUR
0x00
0x0219
Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 2
RUR
0x00
0x021A
Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 1
RUR
0x00
0x021B
Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 0
RUR
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/W
0x00
0x021C - 0x021E Reserved
0x021F
0x0220 - 0x0222
0x0223
0x0224 -0x0226
0x0227
Receive STS-1/STS-3 Transport - Receive K1 Byte Value Register
Reserved
Receive STS-1/STS-3 Transport - Receive K2 Byte Value Register
Reserved
Receive STS-1/STS-3 Transport - Receive S1 Byte Value Register
0x0228 - 0x022A Reserved
0x022B
Receive STS-1/STS-3 Transport - Receive In-Sync Threshold Register
0x022C - 0x022D Reserved
0x022E
Receive STS-1/STS-3 Transport - Receive LOS Threshold Register - MSB
R/W
0x00
0x022F
Receive STS-1/STS-3 Transport - Receive LOS Threshold Register - LSB
R/W
0x00
0x0230
Reserved
0x0231
Receive STS-1/STS-3 Transport - Receive SF Defect Declare Monitor
Interval Register - Byte 2
R/W
0x00
0x0232
Receive STS-1/STS-3 Transport - Receive SF Defect Declare Monitor
Interval Register - Byte 1
R/W
0x00
0x0233
Receive STS-1/STS-3 Transport - Receive SF Defect Declare Monitor
Interval Register - Byte 0
R/W
0x00
R/W
0x00
0x0234 - 0x0235
0x0236
Reserved
Receive STS-1/STS-3 Transport - Receive SF Defect Set Threshold Register - Byte 1
7
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0237
Receive STS-1/STS-3 Transport - Receive SF Defect Set Threshold Register - Byte 0
R/W
0x00
0x0238 - 0x0239
Reserved
0x023A
Receive STS-1/STS-3 Transport - Receive SF Defect Clear Threshold
Register - Byte 1
R/W
0x00
0x023B
Receive STS-1/STS-3 Transport - Receive SF Defect Clear Threshold
Register - Byte 0
R/W
0x00
0x023C
Reserved
0x023D
Receive STS-1/STS-3 Transport - Receive SD Defect Declare Monitor
Interval - Byte 2
R/W
0x00
0x023E
Receive STS-1/STS-3 Transport - Receive SD Defect Declare Monitor
Interval - Byte 1
R/W
0x00
0x023F
Receive STS-1/STS-3 Transport - Receive SD Defect Declare Monitor
Interval - Byte 0
R/W
0x00
0x0240 - 0x0241
Reserved
0x0242
Receive STS-1/STS-3 Transport - Receive SD Defect Set Threshold Register - Byte 1
R/W
0x00
0x0243
Receive STS-1/STS-3 Transport - Receive SD Defect Set Threshold Register - Byte 0
R/W
0x00
0x0244 - 0x0245
Reserved
0x0246
Receive STS-1/STS-3 Transport - Receive SD Defect Clear Threshold
Register - Byte 1
R/W
0x00
0x0247
Receive STS-1/STS-3 Transport - Receive SD Defect Clear Threshold
Register - Byte 0
R/W
0x00
R/W
0x00
R/W
0x00
0x0248 - 0x024A Reserved
0x024B
0x024C -0x024E
0x024F
0x0250 - 0x0251
Receive STS-1/STS-3 Transport - SEF Force Register
Reserved
Receive STS-1/STS-3 Transport - Receive J0 Byte/Section Trace Message Control Register
Reserved
0x0252
Receive STS-1/STS-3 Transport - Receive SD Defect Error Burst Tolerance Register - Byte 1
R/W
0x00
0x0253
Receive STS-1/STS-3 Transport - Receive SD Defect Error Burst Tolerance Register - Byte 0
R/W
0x00
R/W
0x00
0x0254 - 0x0255
0x0256
Reserved
Receive STS-1/STS-3 Transport - Receive SF Defect Error Burst Tolerance Register - Byte 1
8
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
R/W
0x00
0x0257
Receive STS-1/STS-3 Transport - Receive SF Defect Error Burst Tolerance Register - Byte 0
0x0258
Reserved
0x0259
Receive STS-1/STS-3 Transport - Receive SD Defect Clear Monitor Interval - Byte 2
R/W
0x00
0x025A
Receive STS-1/STS-3 Transport - Receive SD Defect Clear Monitor Interval - Byte 1
R/W
0x00
0x025B
Receive STS-1/STS-3 Transport - Receive SD Defect Clear Monitor Interval - Byte 0
R/W
0x00
0x025C
Reserved
0x025D
Receive STS-1/STS-3 Transport - Receive SF Defect Clear Monitor Interval - Byte 2
R/W
0x00
0x025E
Receive STS-1/STS-3 Transport - Receive SF Defect Clear Monitor Interval - Byte 1
R/W
0x00
0x025F
Receive STS-1/STS-3 Transport - Receive SF Defect Clear Monitor Interval - Byte 0
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
0x0260 - 0x0262
0x0263
0x0264 - 0x0266
0x0267
Reserved
Receive STS-1/STS-3 Transport - Auto AIS Control Register
Reserved
Receive STS-1/STS-3 Transport - Serial Port Control Register
0x0268 - 0x026A Reserved
0x026B
Receive STS-1/STS-3 Transport - Auto AIS (in Downstream T1/E1) Register
0x026C - 0x026D Reserved
0x026E
Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register - Byte
1
RUR
0x00
0x026F
Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register - Byte
0
RUR
0x00
0x0270 - 0x0279
Reserved
0x027A
Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect
Address Register - Byte 1
W
0x00
0x027B
Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect
Address Register - Byte 0
W
0x00
0x027C
Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect
Data Register - Byte 3
W
0x00
0x027D
Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect
Data Register - Byte 2
W
0x00
9
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x027E
Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect
Data Register - Byte 1
W
0x00
0x027F
Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect
Data Register - Byte 0
W
0x00
0x0280
Reserved
TYPE
DEFAULT
VALUE
R/W
0x00
R/W
0x00
TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
0x0281
Receive STS-1/STS-3 Path - Receive Control Register - Byte 2
0x0282
Reserved
0x0283
Receive STS-1/STS-3 Path - Receive Control Register - Byte 0
0x0284 - 0x0285
Reserved
0x0286
Receive STS-1/STS-3 Path - Receive Status Register - Byte 1
R/O
0x00
0x0287
Receive STS-1/STS-3 Path - Receive Status Register - Byte 0
R/O
0x00
0x0288
Reserved
0x0289
Receive STS-1/STS-3 Path - Receive Interrupt Status Register - Byte 2
RUR
0x00
0x028A
Receive STS-1/STS-3 Path - Receive Interrupt Status Register - Byte 1
RUR
0x00
0x028B
Receive STS-1/STS-3 Path - Receive Interrupt Status Register - Byte 0
RUR
0x00
0x028C
Reserved
0x028D
Receive STS-1/STS-3 Path - Receive Interrupt Enable Register - Byte 2
R/W
0x00
0x028E
Receive STS-1/STS-3 Path - Receive Interrupt Enable Register - Byte 1
R/W
0x00
0x028F
Receive STS-1/STS-3 Path - Receive Interrupt Enable Register - Byte 0
R/W
0x00
R/O & R/W
0x00
0x0290 - 0x0292
0x0293
0x0294 - 0x295
Reserved
Receive STS-1/STS-3 Path - Receive RDI-P Register
Reserved
0x0296
Receive STS-1/STS-3 Path - Receive C2 (Path Label) Byte Accepted
Register
R/O
0xFF
0x0297
Receive STS-1/STS-3 Path - Receive C2 (Path Label) Byte Expected
Register
R/W
0xFF
0x0298
Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte
3
RUR
0x00
0x0299
Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte
2
RUR
0x00
0x029A
Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte
1
RUR
0x00
10
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x029B
Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte
0
RUR
0x00
0x029C
Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 3
RUR
0x00
0x029D
Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 2
RUR
0x00
0x029E
Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 1
RUR
0x00
0x029F
Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 0
RUR
0x00
R/W
0x00
0x02A0 - 0x02A2 Reserved
0x02A3
Receive STS-1/STS-3 Path - Receive J1 Byte/Path Trace Message Control Register
0x02A4 - 0x02A5 Reserved
0x02A6
Receive STS-1/STS-3 - Receive Pointer Value Register - Byte 1
R/O
0x00
0x02A7
Receive STS-1/STS-3 - Receive Pointer Value Register - Byte 0
R/O
0x00
R/O
0x00
R/O
0x00
0x02A8 - 0x02AA Reserved
0x02AB
Receive STS-1/STS-3 - Receive LOP-C Status Register
0x02AC - 0x02B2 Reserved
0x02B3
Receive STS-1/STS-3 - Receive AIS-C Status Register
0x02B4 - 0x02B8 Reserved
0x02B9
Receive STS-1/STS-3 - Receive Auto AIS - C2 Byte Value Register
R/W
0x00
0x02BA
Receive STS-1/STS-3 - Receive Auto AIS - C2 Byte Control Register
R/W
0x00
0x02BB
Receive STS-1/STS-3 - Receive Auto AIS Control Register
R/W
0x00
R/W
0x00
0x02BC - 0x02BE Reserved
0x02BF
0x02C0 -0x02C2
Receive STS-1/STS-3 - Receive Serial Port Control Register
Reserved
0x02C3
Receive STS-1/STS-3 - Auto AIS (in Downstream T1/E1) Register
R/W
0x00
0x02C4
Receive STS-1/STS-3 - Receive Negative Pointer Adjustment Count Register - Byte 1
RUR
0x00
0x02C5
Receive STS-1/STS-3 - Receive Negative Pointer Adjustment Count Register - Byte 0
RUR
0x00
0x02C6
Receive STS-1/STS-3 - Receive Positive Pointer Adjustment Count Register - Byte 1
RUR
0x00
0x02C7
Receive STS-1/STS-3 - Receive Positive Pointer Adjustment Count Register - Byte 0
RUR
0x00
R/O
0x00
0x02C8 - 0x02D2 Reserved
0x02D3
Receive STS-1/STS-3 - Receive J1 Byte Value Register
0x02D4 - 0x02D6 Reserved
11
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
0x02D7
REGISTER NAME
Receive STS-1/STS-3 - Receive B3 Byte Value Register
TYPE
DEFAULT
VALUE
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
0x02D8 - 0x02DA Reserved
0x02DB
Receive STS-1/STS-3 - Receive C2 Byte Value Register
0x02DC - 0x02DE Reserved
0x02DF
Receive STS-1/STS-3 - Receive G1 Byte Value Register
0x02E0 - 0x02E2 Reserved
0x02E3
Receive STS-1/STS-3 - Receive F2 Byte Value Register
0x02E4 - 0x02E6 Reserved
0x02E7
Receive STS-1/STS-3 - Receive H4 Byte Value Register
0x02E8 - 0x02EA Reserved
0x02EB
Receive STS-1/STS-3 - Receive Z3 Byte Value Register
0x02EC - 0x02EE Reserved
0x02EF
Receive STS-1/STS-3 - Receive Z4 Byte Value Register
0x02F0 - 0x02F2 Reserved
0x02F3
Receive STS-1/STS-3 - Receive Z5 Byte Value Register
0x02F4 - 0x02FF Reserved
TABLE 6: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER
ADDRESS
LOCATION
TYPE
DEFAULT
VALUE
0x0300 - 0x033F Receive STS-1/STS-3 Transport - Receive Section Trace Message Buffer
R/O
0x00
0x0340 - 0x03FF Reserved
R/O
0x00
REGISTER NAME
TABLE 7: RECEIVE STS-1/STS-3 PATH - RECEIVE PATH TRACE MESSAGE BUFFER
ADDRESS
LOCATION
TYPE
DEFAULT
VALUE
0x0400 - 0x043F Receive STS-1/STS-3 Path - Receive Path Trace Message Buffer
R/O
0x00
0x0440 - 0x0580 Reserved
R/O
0x00
REGISTER NAME
TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
ADDRESS
LOCATION
REGISTER NAME
0x0581
Receive TU-3 Path - Receive Control Register - Byte 2
0x0582
Reserved
12
TYPE
DEFAULT
VALUE
R/W
0x00
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
ADDRESS
LOCATION
0x0583
REGISTER NAME
Receive TU-3 Path - Receive Control Register - Byte 0
TYPE
DEFAULT
VALUE
R/W
0x00
0x0584 - 0x0585 Reserved
0x0586
Receive TU-3 Path - Receive Status Register - Byte 1
R/O
0x00
0x0587
Receive TU-3 Path - Receive Status Register - Byte 0
R/O
0x00
0x0588
Reserved
0x0589
Receive TU-3 Path - Receive Interrupt Status Register - Byte 2
RUR
0x00
0x058A
Receive TU-3 Path - Receive Interrupt Status Register - Byte 1
RUR
0x00
0x058B
Receive TU-3 Path - Receive Interrupt Status Register - Byte 0
RUR
0x00
0x058C
Reserved
0x058D
Receive TU-3 Path - Receive Interrupt Enable Register - Byte 2
R/W
0x00
0x058E
Receive TU-3 Path - Receive Interrupt Enable Register - Byte 1
R/W
0x00
0x058F
Receive TU-3 Path - Receive Interrupt Enable Register - Byte 0
R/W
0x00
R/O & R/W
0x00
0x0590 - 0x0592 Reserved
0x0593
Receive TU-3 Path - Receive RDI-P Register
0x0594 - 0x0595 Reserved
0x0596
Receive TU-3 Path - Receive C2 (Path Label) Byte Accepted Register
R/O
0xFF
0x0597
Receive TU-3 Path - Receive C2 (Path Label) Byte Expected Register
R/W
0xFF
0x0598
Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 3
RUR
0x00
0x0599
Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 2
RUR
0x00
0x059A
Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 1
RUR
0x00
0x059B
Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 0
RUR
0x00
0x059C
Receive TU-3 Path - Receive REI-P Event Count Register - Byte 3
RUR
0x00
0x059D
Receive TU-3 Path - Receive REI-P Event Count Register - Byte 2
RUR
0x00
0x059E
Receive TU-3 Path - Receive REI-P Event Count Register - Byte 1
RUR
0x00
0x059F
Receive TU-3 Path - Receive REI-P Event Count Register - Byte 0
RUR
0x00
R/W
0x00
R/O
0x00
R/O
0x00
0x05A0 - 0x05A2 Reserved
0x05A3
Receive TU-3 Path - Receive J1 Byte/Path Trace Message Control Register
0x05A4 - 0x05A5 Reserved
0x05A6
Receive TU-3 Path - Receive Pointer Value Register - Byte 1
0x05A7
Receive TU-3 Path - Receive Pointer Value Register - Byte 0
0x05A8 - 0x05AA Reserved
0x05AB
Receive TU-3 Path - Receive LOP-C Status Register
13
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
R/O
0x00
0x05AC - 0x05B2 Reserved
0x05B3
Receive TU-3 Path - Receive AIS-C Status Register
0x05B4 - 0x05B8 Reserved
0x05B9
Receive TU-3 Path - Receive Auto AIS - C2 Byte Value Register
R/W
0x00
0x05BA
Receive TU-3 Path - Receive Auto AIS - C2 Byte Control Register
R/W
0x00
0x05BB
Receive TU-3 Path - Receive Auto AIS Control Register
R/W
0x00
R/W
0x00
0x05BC - 0x05BE Reserved
0x05BF
Receive TU-3 Path - Receive Serial Port Control Register
0x05C0 - 0x05C2 Reserved
0x05C3
Receive TU-3 Path - Auto AIS (in Downstream T1/E1) Register
R/W
0x00
0x05C4
Receive TU-3 Path - Receive Negative Pointer Adjustment Count Register
- Byte 1
RUR
0x00
0x05C5
Receive TU-3 Path - Receive Negative Pointer Adjustment Count Register
- Byte 0
RUR
0x00
0x05C6
Receive TU-3 Path - Receive Positive Pointer Adjustment Count Register Byte 1
RUR
0x00
0x05C7
Receive TU-3 Path - Receive Positive Pointer Adjustment Count Register Byte 0
RUR
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
R/O
0x00
0x05C8 - 0x05D2 Reserved
0x05D3
Receive TU-3 Path - Receive J1 Byte Value Register
0x05D4 - 0x05D6 Reserved
0x05D7
Receive TU-3 Path - Receive B3 Byte Value Register
0x05D8 - 0x05DA Reserved
0x05DB
Receive TU-3 Path - Receive C2 Byte Value Register
0x05DC - 0x05DE Reserved
0x05DF
Receive TU-3 Path - Receive G1 Byte Value Register
0x05E0 - 0x05E2 Reserved
0x05E3
Receive TU-3 Path - Receive F2 Byte Value Register
0x05E4 - 0x05E6 Reserved
0x05E7
Receive TU-3 Path - Receive H4 Byte Value Register
0x05E8 - 0x05EA Reserved
0x05EB
Receive TU-3 Path - Receive Z3 Byte Value Register
0x05EC - 0x05EE Reserved
0x05EF
Receive TU-3 Path - Receive Z4 Byte Value Register
14
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
R/O
0x00
0x05F0 - 0x05F2 Reserved
0x05F3
Receive TU-3 Path - Receive Z5 Byte Value Register
0x05F4 - 0x05FF Reserved
TABLE 9: RECEIVE TU-3 POH PROCESSOR BLOCK - RECEIVE PATH TRACE MESSAGE BUFFER (SDH/TUG-3
APPLICATIONS ONLY)
ADDRESS
LOCATION
REGISTER NAME
0x0600 - 0x063F Receive TU-3 POH Processor Block - Receive Path Trace Message Buffer
TYPE
DEFAULT
VALUE
R/O
0x00
0x0640 - 0x06FF Reserved
TABLE 10: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0700
Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 3
R/W
0x00
0x0701
Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 2
R/W
0x00
0x0702
Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 1
R/W
0x00
0x0703
Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 0
R/W
0x00
0x0704 - 0x0715 Reserved
0x0716
Transmit STS-1/STS-3 Transport - Transmit A1 Byte Error Mask Register Byte 1
R/W
0x00
0x0717
Transmit STS-1/STS-3 Transport - Transmit A1 Byte Error Mask Register Byte 0
R/W
0x00
0x0718 - 0x071D Reserved
0x071E
Transmit STS-1/STS-3 Transport - Transmit A2 Byte Error Mask Register Byte 1
R/W
0x00
0x071F
Transmit STS-1/STS-3 Transport - Transmit A2 Byte Error Mask Register Byte 0
R/W
0x00
Transmit STS-1/STS-3 Transport - Transmit B1 Byte Error Mask Register
R/W
0x00
0x0726
Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Mask Register Byte 1
R/W
0x00
0x0727
Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Mask Register Byte 0
R/W
0x00
0x0720 - 0x0722 Reserved
0x0723
0x0724 - 0x0725
0x0728 - 0x072A Reserved
15
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 10: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
ADDRESS
LOCATION
0x072B
REGISTER NAME
TYPE
DEFAULT
VALUE
Transmit STS-1/STS-3 Transport - Transmit B2 Byte Bit Error Mask Register
R/W
0x00
0x072C - 0x072D Reserved
0x072E
Transmit STS-1/STS-3 Transport - Transmit K1 Byte Value Register
R/W
0x00
0x072F
Transmit STS-1/STS-3 Transport - Transmit K2 Byte Value Register
R/W
0x00
0x0730 - 0x0732 Reserved
0x0733
Transmit STS-1/STS-3 Transport - Transmit RDI-L Control Register
R/W
0x00
0x0734
Transmit STS-1/STS-3 Transport - Transmit M0/M1 Byte Control Register
R/W
0x00
0x0735
Reserved
0x0736
Transmit STS-1/STS-3 Transport - Transmit M0/M1 Byte Pointer Register
R/W
0x00
0x0737
Transmit STS-1/STS-3 Transport - Transmit M0/M1 Byte Value Register
R/W
0x00
0x0738
Transmit STS-1/STS-3 Transport - Transmit S1 Byte Control Register
R/W
0x00
0x0739
Reserved
0x073A
Transmit STS-1STS-3 Transport - Transmit S1 Pointer Register
R/W
0x00
0x073B
Transmit STS-1/STS-3 Transport - Transmit S1 Byte Value Register
R/W
0x00
0x073C
Transmit STS-1/STS-3 Transport - Transmit F1 Byte Control Register
R/W
0x00
0x073D
Reserved
0x073E
Transmit STS-1/STS-3 Transport - Transmit F1 Byte Pointer Register
R/W
0x00
0x073F
Transmit STS-1/STS-3 Transport - Transmit F1 Byte Value Register
R/W
0x00
0x0740
Transmit STS-1/STS-3 Transport - Transmit E1 Byte Control Register
R/W
0x00
0x0741
Reserved
0x0742
Transmit STS-1/STS-3 Transport - Transmit E1 Pointer Register
R/W
0x00
0x0743
Transmit STS-1/STS-3 Transport - Transmit E1 Byte Value Register
R/W
0x00
0x0744
Transmit STS-1/STS-3 Transport - Transmit E2 Byte Control Register
R/W
0x00
0x0745
Reserved
0x0746
Transmit STS-1/STS-3 Transport - Transmit E2 Byte Pointer Register
R/W
0x00
0x0747
Transmit STS-1/STS-3 Transport - Transmit E2 Byte Value Register
R/W
0x00
R/W
0x00
R/W
0x00
0x0748 - 0x074A Reserved
0x074B
Transmit STS-1/STS-3 Transport - Transmit J0 Byte Value Register
0x074C -0x074E Reserved
0x074F
Transmit STS-1/STS-3 Transport - Transmit J0 Byte/Section Trace Message Control Register
0x0750 - 0x0780 Reserved
16
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 11: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0781
Transmit STS-1/STS-3 Path - Transmit Path Control Register - Byte 2
R/W
0x00
0x0782
Transmit STS-1/STS-3 Path - Transmit Path Control Register - Byte 1
R/W
0x00
0x0783
Transmit STS-1/STS-3 Path - Transmit Path Control Register - Byte 0
R/W
0x00
R/W
0x00
0x0784 - 0x0792
0x0793
0x0794 - 0x0796
Reserved
Transmit STS-1/STS-3 Path - Transmit J1 Byte Value Register
Reserved
0x0796
Transmit STS-1/STS-3 Path - Transmit B3 Byte Pass Thru Register
R/W
0x00
0x0797
Transmit STS-1/STS-3 Path - Transmit B3 Byte Mask Register
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
0x0798 - 0x079A
0x079B
Reserved
Transmit STS-1/STS-3 Path - Transmit C2 Byte Value Register
0x079C - 0x079E Reserved
0x079F
Transmit STS-1/STS-3 Path - Transmit G1 Byte Value Register
0x07A0 - 0x07A2 Reserved
0x07A3
Transmit STS-1/STS-3 Path - Transmit F2 Byte Value Register
0x07A4 - 0x07A6 Reserved
0x07A7
Transmit STS-1/STS-3 Path - Transmit H4 Byte Value Register
0x07A8 - 0x07AA Reserved
0x07AB
Transmit STS-1/STS-3 Path - Transmit Z3 Byte Value Register
0x07AC - 0x07AE Reserved
0x07AF
Transmit STS-1/STS-3 Path - Transmit Z4 Byte Value Register
0x07B0 - 0x07B2 Reserved
0x07B3
Transmit STS-1/STS-3 Path - Transmit Z5 Byte Value Register
0x07B4 - 0x07B6 Reserved
0x07B7
Transmit STS-1/STS-3 Path - Transmit Control Register - Byte 0
0x07B8 - 0x07BA Reserved
0x07BB
Transmit STS-1/STS-3 Path - Transmit J1 Byte/Path Trace Message Control Register
0x07BC - 0x07BE Reserved
0x07BF
Transmit STS-1/STS-3 Path - Transmit Arbitrary Pointer (H1 Byte) Value
Register
0x07C0 - 0x07C2 Reserved
0x07C3
Transmit STS-1/STS-3 Path - Transmit Arbitrary Pointer (H2 Byte) Value
Register
17
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 11: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x07C4 - 0x07C5 Reserved
0x07C6
Transmit STS-1/STS-3 Path - Current Pointer Value Register - High-Byte
R/O
0x02
0x07C7
Transmit STS-1/STS-3 Path - Current Pointer Value Register - Low-Byte
R/O
0x0A
0x07C8
Reserved
0x07C9
Transmit STS-1/STS-3 Path - Transmit RDI-P Control Register - Byte 2
R/W
0x00
0x07CA
Transmit STS-1/STS-3 Path - Transmit RDI-P Control Register - Byte 1
R/W
0x00
0x07CB
Transmit STS-1/STS-3 Path - Transmit RDI-P Control Register - Byte 0
R/W
0x00
0x07CA - 0x07CE Reserved
0x07CF
Transmit STS-1/STS-3 Path - Transmit Path Serial Port Control Register
R/W
0x00
0x07D0
Transmit STS-1/STS-3 - Transmit Negative Pointer Adjustment Count
Register - Byte 1
RUR
0x00
0x07D1
Transmit STS-1/STS-3 - Transmit Negative Pointer Adjustment Count
Register - Byte 0
RUR
0x00
0x07D2
Transmit STS-1/STS-3 - Transmit Positive Pointer Adjustment Count Register - Byte 1
RUR
0x00
0x07D3
Transmit STS-1/STS-3 - Transmit Positive Pointer Adjustment Count Register - Byte 0
RUR
0x00
0x07D4 - 0x07FF Reserved
TABLE 12: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER
ADDRESS
LOCATION
REGISTER NAME
0x0800 - 0x083F Transmit STS-1/STS-3 Transport - Transmit Section Trace Message Buffer
TYPE
DEFAULT
VALUE
R/W
0x00
0x0840 - 0x08FF Reserved
TABLE 13: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER
ADDRESS
LOCATION
TYPE
DEFAULT
VALUE
0x0900 - 0x093F Transmit STS-1/STS-3 Path - Transmit Path Trace Message Buffer
R/W
0x00
0x0940 - 0x0A80 Reserved
R/O
0x00
REGISTER NAME
18
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 14: TRANSMIT TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0A81
Transmit TU-3 Path - Transmit Path Control Register - Byte 2
R/W
0x00
0x0A82
Transmit TU-3 Path - Transmit Path Control Register - Byte 1
R/W
0x00
0x0A83
Transmit TU-3 Path - Transmit Path Control Register - Byte 0
R/W
0x00
R/W
0x00
0x0A84 -0x0A92
0x0A93
Reserved
Transmit TU-3 Path - Transmit J1 Byte Value Register
0x0A94 - 0x0A95 Reserved
0x0A96
Transmit TU-3 Path - Transmit B3 Byte Pass Thru Register
R/W
0x00
0x0A97
Transmit TU-3 Path - Transmit B3 Byte Mask Register
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
R/W
0x00
0x0A98 - 0x0A9A Reserved
0x0A9B
Transmit TU-3 Path - Transmit C2 Byte Value Register
0x0A9C - 0x0A9E Reserved
0x0A9F
Transmit TU-3 Path - Transmit G1 Byte Value Register
0x0AA0 - 0x0AA2 Reserved
0x0AA3
Transmit TU-3 Path - Transmit F2 Byte Value Register
0x0AA4 - 0x0AA6 Reserved
0x0AA7
Transmit TU-3 Path - Transmit H4 Byte Value Register
0x0AA8 - 0x0AAA Reserved
0x0AAB
Transmit TU-3 Path - Transmit Z3 Byte Value Register
0x0AAC - 0x0AAE Reserved
0x0AAF
Transmit TU-3 Path - Transmit Z4 Byte Value Register
0x0AB0 - 0x0AB2 Reserved
0x0AB3
Transmit TU-3 Path - Transmit Z5 Byte Value Register
0x0AB4 - 0x0AB6 Reserved
0x0AB7
Transmit TU-3 Path - Transmit Control Register - Byte 0
0x0AB8 - 0x0ABA Reserved
0x0ABB
Transmit TU-3 Path - Transmit J1 Byte/Path Trace Message Control Register
0x0ABC - 0x0ABE Reserved
0x0ABF
Transmit TU-3 Path - Transmit Arbitrary Pointer (H1 Byte) Value Register
0x0AC0 -0x0AC2 Reserved
0x0AC3
Transmit TU-3 Path - Transmit Arbitrary Pointer (H2 Byte) Value Register
0x0AC4 - 0x0AC5 Reserved
19
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 14: TRANSMIT TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0AC6
Transmit TU-3 Path - Current Pointer Value Register - High Byte
R/O
0x02
0x0AC7
Transmit TU-3 Path - Current Pointer Value Register - Low Byte
R/O
0x0A
0x0AC8
Reserved
0x0AC9
Transmit TU-3 Path - Transmit RDI-P Control Register - Byte 2
R/W
0x00
0x0ACA
Transmit TU-3 Path - Transmit RDI-P Control Register - Byte 1
R/W
0x00
0x0ACB
Transmit TU-3 Path - Transmit RDI-P Control Register - Byte 0
R/W
0x00
0x0ACC - 0x0ACE Reserved
0x0ACF
Transmit TU-3 Path - Transmit Path Serial Port Control Register
R/W
0x00
0x0AD0
Transmit TU-3 Path - Transmit Negative Pointer Adjustment Count Register - Byte 1
RUR
0x00
0x0AD1
Transmit TU-3 Path - Transmit Negative Pointer Adjustment Count Register - Byte 0
RUR
0x00
0x0AD2
Transmit TU-3 Path - Transmit Positive Pointer Adjustment Count Register
- Byte 1
RUR
0x00
0x0AD3
Transmit TU-3 Path - Transmit Positive Pointer Adjustment Count Register
- Byte 0
RUR
0x00
Reserved
R/O
0x00
0x0AD4 - 0xAFF
TABLE 15: TRANSMIT TU-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER
ADDRESS
LOCATION
TYPE
DEFAULT
VALUE
0x0B00 - 0x0B3F Transmit TU-3 POH Processor Block - Transmit Path Trace Message
Buffer
R/W
0x00
0x0B40 - 0x0BFF Reserved
R/O
0x00
TYPE
DEFAULT
VALUE
R/W
0x00
REGISTER NAME
TABLE 16: VT MAPPER CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
0x0C00 - 0x0C02 Reserved
0x0C03
Global Control - VT Mapper Control Block - VT Mapper Block Level Control Register
0x0C04 - 0x0C05 Reserved
0x0C06
Global Control - VT Mapper Control Block - Composite Status Register
R/O
0x00
0x0C07
Global Control - VT Mapper Control Block - Composite Status Register
R/O
0x00
0x0C08 - 0x0C09 Reserved
20
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 16: VT MAPPER CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0C0A
Global Control - VT Mapper Control Block - Composite Interrupt Enable
Register
R/W
0x00
0x0C0B
Global Control - VT Mapper Control Block - Composite Interrupt Enable
Register
R/W
0x00
0x0C0C - 0x0C0D Reserved
0x0C0E
Global Control - VT Mapper Control Block - Test Pattern Control Register Byte 1
R/W & R/O
0x00
0x0C0F
Global Control - VT Mapper Control Block - Test Pattern Control Register Byte 0
R/O
0x00
0x0C10 - 0x0C11 Reserved
0x0C12
Global Control - VT Mapper Control Block - Test Pattern Drop Register Byte 1
R/W
0x00
0x0C13
Global Control - VT Mapper Control Block - Test Pattern Drop Register Byte 0
R/W
0x00
0x0C14 - 0x0C15 Reserved
0x0C16
Global Control - VT Mapper Control Block - Test Pattern Detector Error
Register - Upper Byte
RUR
0x00
0x0C17
Global Control - VT Mapper Control Block - Test Pattern Detector Error
Register - Lower Byte
RUR
0x00
0x0C18 - 0x0C19 Reserved
0x0C1A
Global Control - VT Mapper Control Block - Transmit Tributary Size Select
Register - Byte 1
R/W
0x00
0x0C1B
Global Control - VT Mapper Control Block - Transmit Tributary Size Select
Register - Byte 0
R/W
0x00
0x0C1C - 0x0C1D Reserved
0x0C1E
Global Control - VT Mapper Control Block - Receive Tributary Size Select
Register - Byte 1
R/W
0x00
0x0C1F
Global Control - VT Mapper Control Block - Receive Tributary Size Select
Register - Byte 0
R/W
0x00
0x0C20 - 0x0D01 Reserved
TABLE 17: DS3 MAPPER CONTROL REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0D02
DS3 Mapper Block - Control Register - Byte 1
R/W
0x03
0x0D03
DS3 Mapper Block - Control Register - Byte 0
R/W
0x00
R/O
0x03
0x0D04 - 0x0D05 Reserved
0x0D06
DS3 Mapper Block - Receive Mapper Status Register - Byte 1
21
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 17: DS3 MAPPER CONTROL REGISTERS
ADDRESS
LOCATION
0x0D07
REGISTER NAME
DS3 Mapper Block - Receive Mapper Status Register - Byte 0
TYPE
DEFAULT
VALUE
R/O
0x00
RUR
0x00
R/W
0x00
0x0D08 - 0x0D0A Reserved
0x0D0B
DS3 Mapper Block - Receive Mapper Interrupt Status Register - Byte 0
0x0D0C - 0x0D0D Reserved
0x0D0E
DS3 Mapper Block - Receive Mapper Interrupt Enable Register - Byte 0
0x0D0F - 0x0D20 Reserved
0x0D21
Pointer Justification Status Register - Byte 2
R/O
0x00
0x0D22
Pointer Justification Status Register - Byte 1
R/O
0x00
0x0D23
Pointer Justification Status Register - Byte 0
R/O
0x00
0x0D24 - 0x0D25 Reserved
0x0D26
Pointer Justification Jitter Control Register - Byte 1
R/W
0xC0
0x0D27
Pointer Justification Jitter Control Register - Byte 0
R/W
0x80
0x0D28 - 0x0DFF Reserved
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0E00
DS3 Framer and M13 MUX Block - Operating Mode Register
R/W
0x23
0x0E01
DS3 Framer and M13 MUX Block - I/O Control Register
R/W
0xC0
0x0E02 - 0x0E03 Reserved
0x0E04
DS3 Framer and M13 MUX Block - Block Interrupt Enable Register
R/W
0x00
0x0E05
DS3 Framer and M13 MUX Block - Block Interrupt Status Register
R/O
0x00
0x0E06
Reserved
R/W
0x00
0x0E07
DS3 Framer and M13 MUX Block - M23 Configuration Register
R/W
0x00
0x0E08
DS3 Framer and M13 MUX Block - M23 Transmit DS2 AIS Register
R/W
0x00
0x0E09
DS3 Framer and M13 MUX Block - M23 DS2 Loop-back Request Register
R/W
0x00
0x0E0A
DS3 Framer and M13 MUX Block - M23 Loop-back Activation Register
R/W
0x00
0x0E0B
DS3 Framer and M13 MUX Block - M23 MUX Force DS2 AIS Command
Register
R/W
0x00
0x0E0C
DS3 Framer and M13 MUX Block - DS3 Test Register # 1
R/W
0x00
0x0E0D
Reserved
R/O
0x00
0x0E0E
DS3 Framer and M13 MUX Block - DS3 Test Register # 2
R/W
0x00
22
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0E10
DS3 Framer and M13 MUX Block - Receive DS3 Configuration & Status
Register
R/W
0x10
0x0E11
DS3 Framer and M13 MUX Block - Receive DS3 Status Register
R/W
0x00
0x0E12
DS3 Framer and M13 MUX Block - Receive DS3 Interrupt Enable Register
R/W
0x00
0x0E13
DS3 Framer and M13 MUX Block - Receive DS3 Interrupt Status Register
RUR
0x00
0x0E14
DS3 Framer and M13 MUX Block - Receive DS3 Sync Detect Register
R/W
0x00
0x0E15
Reserved
R/O
0x00
0x0E16
S3 Framer and M13 MUX Block - Receive DS3 FEAC Register
R/O
0x7E
0x0E17
DS3 Framer and M13 MUX Block - Receive DS3 FEAC Interrupt
Enable/Status Register
R/W
0x00
0x0E18
DS3 Framer and M13 MUX Block - Receive DS3 LAPD Control Register
R/W
0x00
0x0E19
DS3 Framer and M13 MUX Block - Receive DS3 LAPD Status Register
R/W
0x00
0x0E1A
M12 DS2 # 1 Configuration Register
R/W
0x00
0x0E1B
DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2
Channel # 2
R/W
0x00
0x0E1C
DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2
Channel # 3
R/W
0x00
0x0E1D
DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2
Channel # 4
R/W
0x00
0x0E1E
DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2
Channel # 5
R/W
0x00
0x0E1F
DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2
Channel # 6
R/W
0x00
0x0E20
DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2
Channel # 7
R/W
0x00
0x0E21
DS3 Framer and M13 MUX Block - M12 De-MUX Force DS1/E1 AIS Register - DS2 # Channel 1
R/W
0x00
0x0E22
DS3 Framer and M13 MUX Block - M12 DS2 # 2 AIS Register
R/W
0x00
0x0E23
DS3 Framer and M13 MUX Block - M12 DS2 # 3 AIS Register
R/W
0x00
0x0E24
DS3 Framer and M13 MUX Block - M12 DS2 # 4 AIS Register
R/W
0x00
0x0E25
DS3 Framer and M13 MUX Block - M12 DS2 # 5 AIS Register
R/W
0x00
0x0E26
DS3 Framer and M13 MUX Block - M12 DS2 # 6 AIS Register
R/W
0x00
0x0E27
DS3 Framer and M13 MUX Block - M12 DS2 # 7 AIS Register
R/W
0x00
0x0E28
M12 DS2 # 1 Loop-back Request Register
R/W
0x00
0x0E29
M12 DS2 # 2 Loop- back Request Register
R/W
0x00
0x0E2A
M12 DS2 # 3 Loop-back Request Register
R/W
0x00
23
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0E2B
M12 DS2 # 4 Loop-back Request Register
R/W
0x00
0x0E2C
M12 DS2 # 5 Loop-back Request Register
R/W
0x00
0x0E2D
M12 DS2 # 6 Loop-back Request Register
R/W
0x00
0x0E2E
M12 DS2 # 7 Loop-back Request Register
R/W
0x00
0x0E2F
Reserved
R/O
0x00
0x0E30
Transmit DS3 Configuration Register
R/W
0x00
0x0E31
Transmit DS3 FEAC Configuration & Status Register
R/W
0x00
0x0E32
Transmit DS3 FEAC Register
R/W
0x7E
0x0E33
Transmit DS3 LAPD Configuration Register
R/W
0x00
0x0E34
Transmit DS3 LAPD Status/Interrupt Register
R/W
0x00
0x0E35
Transmit DS3 M-Bit Mask Register
R/W
0x00
0x0E36
Transmit DS3 F-Bit Mask Register # 1
R/W
0x00
0x0E37
Transmit DS3 F-Bit Mask Register # 2
R/W
0x00
0x0E38
Transmit DS3 F-Bit Mask Register # 3
R/W
0x00
0x0E39
Transmit DS3 F-Bit Mask Register # 4
R/W
0x00
0x0E3A
M12 DS2 # 1 Framer Configuration Register
R/W
0x00
0x0E3B
M12 DS2 # 2 Framer Configuration Register
R/W
0x00
0x0E3C
M12 DS2 # 3 Framer Configuration Register
R/W
0x00
0x0E3D
M12 DS2 # 4 Framer Configuration Register
R/W
0x00
0x0E3E
M12 DS2 # 5 Framer Configuration Register
R/W
0x00
0x0E3F
M12 DS2 # 6 Framer Configuration Register
R/W
0x00
0x0E40
M12 DS2 # 7 Framer Configuration Register
R/W
0x00
R/O
0x00
0x0E41 - 0x0E4B Reserved
0x0E4C
Transmit DS3 Pattern Register
R/W
0x00
0x0E4D
Auto T1/E1 AIS upon DS3 Defect Condition Register
R/W
0x00
0x0E4E
PMON EXZ Event Count Register - MSB
RUR
0x00
0x0E4F
PMON EXZ Event Count Register - LSB
RUR
0x00
0x0E50
PMON LCV Event Count Register - MSB
RUR
0x00
0x0E51
PMON LCV Event Count Register - LSB
RUR
0x00
0x0E52
PMON Framing Bit Error Count Register - MSB
RUR
0x00
0x0E53
PMON Framing Bit Error Count Register - LSB
RUR
0x00
0x0E54
PMON P-Bit Error Count Register - MSB
RUR
0x00
24
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0E55
PMON P-Bit Error Count Register - LSB
RUR
0x00
0x0E56
PMON FEBE Count Register - MSB
RUR
0x00
0x0E57
PMON FEBE Count Register - LSB
RUR
0x00
0x0E58
PMON CP-Bit Error Count Register - MSB
RUR
0x00
0x0E59
PMON CP-Bit Error Count Register - LSB
RUR
0x00
0x0E5A
PMON DS2 # 1 Framing Bit Error Count Register
RUR
0x00
0x0E5B
PMON DS2 # 2 Framing Bit Error Count Register
RUR
0x00
0x0E5C
PMON DS2 # 3 Framing Bit Error Count Register
RUR
0x00
0x0E5D
PMON DS2 # 4 Framing Bit Error Count Register
RUR
0x00
0x0E5E
PMON DS2 # 5 Framing Bit Error Count Register
RUR
0x00
0x0E5F
PMON DS2 # 6 Framing Bit Error Count Register
RUR
0x00
0x0E60
PMON DS2 # 7 Framing Bit Error Count Register
RUR
0x00
0x0E61
PMON G.747 # 1 Parity Bit Error Count Register
RUR
0x00
0x0E62
PMON G.747 # 2 Parity Bit Error Count Register
RUR
0x00
0x0E63
PMON G.747 # 3 Parity Bit Error Count Register
RUR
0x00
0x0E64
PMON G.747 # 4 Parity Bit Error Count Register
RUR
0x00
0x0E65
PMON G.747 # 5 Parity Bit Error Count Register
RUR
0x00
0x0E66
PMON G.747 # 6 Parity Bit Error Count Register
RUR
0x00
0x0E67
PMON G.747 # 7 Parity Bit Error Count Register
RUR
0x00
0x0E68
PRBS Bit Error Count Register - MSB
RUR
0x00
0x0E69
PRBS Bit Error Count Register - LSB
RUR
0x00
0x0E6A - 0x0E6C Reserved
0x0E6D
One Second Error Status Register
R/O
0x00
0x0E6E
LCV One Second Accumulator Register - MSB
R/O
0x00
0x0E6F
LCV One Second Accumulator Register - LSB
R/O
0x00
0x0E70
Frame Parity Error One Second Accumulator Register - MSB
R/O
0x00
0x0E71
Frame Parity Error One Second Accumulator Register - LSB
R/O
0x00
0x0E72
CP Bit Error One Second Accumulator Register - MSB
R/O
0x00
0x0E73
CP Bit Error One Second Accumulator Register - LSB
R/O
0x00
R/O
0x00
0x0E74 - 0x0E7F Reserved
0x0E80
Line Interface Drive Register
R/W
0x00
0x0E81
Line Interface Scan Register
R/W
0x00
25
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0E82
Reserved
R/O
0x00
0x0E83
Transmit DS3 LAPD Byte Count Register
R/W
0x00
0x0E84
Receive DS3 LAPD Byte Count Register
R/O
0x00
0x0E85 - 0x0E8F Reserved
0x0E90
M23 Receive DS2 Loop-back Request Interrupt Enable Register
R/W
0x00
0x0E91
M23 Receive DS2 Loop-back Request Interrupt Status Register
RUR
0x00
0x0E92
M23 Receive DS2 Loop-back Request Status Register
R/O
0x00
0x0E93
M12 DS2 # 1 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0E94
M12 DS2 # 1 Loop-back Status Register
R/O
0x00
0x0E95
M12 DS2 # 2 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0E96
M12 DS2 # 2 Loop-back Status Register
R/O
0x00
0x0E97
M12 DS2 # 3 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0E98
M12 DS2 # 3 Loop-back Status Register
R/O
0x00
0x0E99
M12 DS2 # 4 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0E9A
M12 DS2 # 4 Loop-back Status Register
R/O
0x00
0x0E9B
M12 DS2 # 5 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0E9C
M12 DS2 # 5 Loop-back Status Register
R/O
0x00
0x0E9D
M12 DS2 # 6 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0E9E
M12 DS2 # 6 Loop-back Status Register
R/O
0x00
0x0E9F
M12 DS2 # 7 Loop-back Interrupt/Interrupt Enable Register
R/W, RUR
0x00
0x0EA0
M12 DS2 # 7 Loop-back Status Register
R/O
0x00
0x0EA1
DS2 # 1 Framer Interrupt Enable Register
R/W
0x00
0x0EA2
DS2 # 1 Framer Interrupt Status Register
RUR
0x00
0x0EA3
DS2 # 1 Framer Status Register
R/O
0x00
0x0EA4
DS2 # 2 Framer Interrupt Enable Register
R/W
0x00
0x0EA5
DS2 # 2 Framer Interrupt Status Register
RUR
0x00
0x0EA6
DS2 # 2 Framer Status Register
R/O
0x00
0x0EA7
DS2 # 3 Framer Interrupt Enable Register
R/W
0x00
0x0EA8
DS2 # 3 Framer Interrupt Status Register
RUR
0x00
0x0EA9
DS2 # 3 Framer Status Register
R/O
0x00
0x0EAA
DS2 # 4 Framer Interrupt Enable Register
R/W
0x00
0x0EAB
DS2 # 4 Framer Interrupt Status Register
RUR
0x00
26
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0x0EAC
DS2 # 4 Framer Status Register
R/O
0x00
0x0EAD
DS2 # 5 Framer Interrupt Enable Register
R/W
0x00
0x0EAE
DS2 # 5 Framer Interrupt Status Register
RUR
0x00
0x0EAF
DS2 # 5 Framer Status Register
R/O
0x00
0x0EB0
DS2 # 6 Framer Interrupt Enable Register
R/W
0x00
0x0EB1
DS2 # 6 Framer Interrupt Status Register
RUR
0x00
0x0EB2
DS2 # 6 Framer Status Register
R/O
0x00
0x0EB3
DS2 # 7 Framer Interrupt Enable Register
R/W
0x00
0x0EB4
DS2 # 7 Framer Interrupt Status Register
RUR
0x00
0x0EB5
DS2 # 7 Framer Status Register
R/O
0x00
R/W
0x00
0x0EB6 -0x0EB7 Reserved
0x0EB8
M13 DeMUX External Alarm Enable Register
0x0EB9 - 0x0EBF Reserved
0x0EC0
LAPD Memory Indirect Address Register
R/W
0x00
0x0EC1
LAPD Memory Indirect Data Register
R/W
0x00
R/O
0x00
0x0EC2 - 0x0FFF Reserved
TABLE 19: T1/E1 LIU CHANNEL CONTROL REGISTERS (WHERE N RANGES FROM 0X01 TO 0X1D)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN000
T1/E1 LIU Register - Byte 0 - Channel 0
R/W
0x00
0xN001
LIU Channel Control Register - Byte 1 - Channel 0
R/W
0x00
0xN002
LIU Channel Control Register - Byte 2 - Channel 0
R/W
0x00
0xN003
LIU Channel Control Register - Byte 3 - Channel 0
R/W
0x00
0xN004
LIU Channel Control Register - Byte 4 - Channel 0
R/W
0x00
0xN005
LIU Channel Control Register - Byte 5 - Channel 0
R/W
0x00
0xN006
LIU Channel Control Register - Byte 6 - Channel 0
R/W
0x00
0xN007
LIU Channel Control Register - Byte 7 - Channel 0
R/W
0x00
0xN008
LIU Channel Control Register - Byte 8 - Channel 0
R/W
0x00
0xN009
LIU Channel Control Register - Byte 9 - Channel 0
R/W
0x00
0xN00A
LIU Channel Control Register - Byte 10 - Channel 0
R/W
0x00
0xN00B
LIU Channel Control Register - Byte 11 - Channel 0
R/W
0x00
0xN00C
LIU Channel Control Register - Byte 12 - Channel 0
R/W
0x00
27
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 19: T1/E1 LIU CHANNEL CONTROL REGISTERS (WHERE N RANGES FROM 0X01 TO 0X1D)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN00D
LIU Channel Control Register - Byte 13 - Channel 0
R/W
0x00
0xN00E
LIU Channel Control Register - Byte 14 - Channel 0
R/W
0x00
0xN00F
LIU Channel Control Register - Byte 15 - Channel 0
R/W
0x00
0xN010
LIU Channel Control Register - Byte 16 - Channel 0
R/W
0x00
0xN011
LIU Channel Control Register - Byte 17 - Channel 0
R/W
0x00
0xN012 - 0xN0FF Reserved
TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN100
Clock Select Register
R/W
0x00
0xN101
Line Interface Control Register
R/W
0x00
Reserved
RUR
0xN107
Framing Select Register
R/W
0x00
0xN108
Alarm Generation Register
R/W
0x00
0xN109
Synchronization Mux Register
R/W
0x00
0xN10A
Transmit Signaling and Data Link Select Register
R/W
0x00
0xN10B
Framing Control Register
R/W
0x00
0xN10C
Receive Signaling Data Link Select Register
R/W
0x00
0xN10D
Receive Signaling Change Register - 0Framing Control Register (E1 Applications Only)
R/W
0x00
0xN10E
Receive Signaling Change Register - 1
R/W
0x00
0xN10F
Receive Signaling Change Register - 2
R/W
0x00
0xN110
Reserved
0xN111
Receive National Bits Register (E1 Applications Only)
R/W
0x00
0xN112
Receive Extra Bits (E1 Applications)Receive In-Sync Register (T1 Applications)
R/W
0x00
0xN113
Data Link control Register
R/W
0x00
0xN114
Transmit Data Link Byte Count Register
R/W
0x00
0xN115
Receive Data Link Byte Count Register
R/W
0x00
0xN102 - 0N106
0xN116 - 0xN117 Reserved
0x1118
DMA 0 Write Configuration Register
R/W
0x00
0x1119
DMA 1 Read Configuration Register
R/W
0x00
28
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN11A
Reserved
0xN11B
LAPD Channel Select Register (T1 Applications)
R/W
0x00
0xN11C
Customer Installation Alarm Generation Register
R/W
0x00
0xN11D
Transmit Performance Report Control Register
R/W
0x00
0xN11E - 0xN11
Reserved
0xN120
Transmit Interface Control Register
R/W
0x00
0xN121
DS1/E1 Test Register - 2
R/W
0x00
0xN122
Receive Interface Control Register
R/W
0x00
0xN123
DS1/E1 Test Register - 1
R/W
0x00
0xN124
Loop Back Code Control Register - Code 0
R/W
0x00
0xN125
Transmit Loop Back Code Control Register
R/W
0x00
0xN126
Receive Loop Back Code Activation Control Register - Code 0
R/W
0x00
0xN127
Receive Loop Back Code Deactivation Control Register - Code 0
R/W
0x00
0xN129
Receive DS1 External Alarm Enable Register
R/W
0x00
0xN12A
Loop-Back Code Control Register - Code 1
R/W
0x00
0xN12B
Receive Loop Back Code Activation Control Register - Code 1
R/W
0x00
0xN12C
Receive Loop Back Code Deactivation Control Register - Code 1
R/W
0x00
0xN12D
Loop-back Code Control Register - Code 2
R/W
0x00
0xN12E
Receive Loop-back Activation Code Control Register - Code 2
R/W
0x00
0xN12F
Receive Loop-back Deactivation Code Control Register - Code 2
R/W
0x00
0xN130
Transmit Sa Select Register (E1 Applications Only)
R/W
0x00
0xN131
Transmit Sa Auto Control Register - Byte 1 (E1 Applications Only)
R/W
0x00
0xN132
Transmit Sa Auto Control Register - Byte 2 (E1 Applications Only)
R/W
0x00
0xN133
Transmit Sa4 Register (E1 Applications Only)
R/W
0x00
0xN134
Transmit Sa5 Register (E1 Applications Only)
R/W
0x00
0xN135
Transmit Sa6 Register (E1 Applications Only)
R/W
0x00
0xN136
Transmit Sa7 Register (E1 Applications Only)
R/W
0x00
0xN137
Transmit Sa8 Register (E1 Applications Only)
R/W
0x00
0xN138 - 0xN13A Reserved
0xN13B
Receive Sa4 Register (E1 Applications Only)
R/W
0x00
0xN13C
Receive Sa5 Register (E1 Applications Only)
R/W
0x00
0xN13D
Receive Sa6 Register (E1 Applications Only)
R/W
0x00
29
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN13E
Receive Sa7 Register (E1 Applications Only)
R/W
0x00
0xN13F
Receive Sa8 Register (E1 Applications Only)
R/W
0x00
R/W
0x00
ADDRESS LOCATION
0xN140 - 0xN142 Reserved
0xN142
Transmit SPRM Control Register
0xN143 - 0xN2FF Reserved
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN300
Transmit Channel Control Register - Channel 0
R/W
0x00
0xN301
Transmit Channel Control Register - Channel 1
R/W
0x00
0xN302
Transmit Channel Control Register - Channel 2
R/W
0x00
0xN303
Transmit Channel Control Register - Channel 3
R/W
0x00
0xN304
Transmit Channel Control Register - Channel 4
R/W
0x00
0xN305
Transmit Channel Control Register - Channel 5
R/W
0x00
0xN306
Transmit Channel Control Register - Channel 6
R/W
0x00
0xN307
Transmit Channel Control Register - Channel 7
R/W
0x00
0xN308
Transmit Channel Control Register - Channel 8
R/W
0x00
0xN309
Transmit Channel Control Register - Channel 9
R/W
0x00
0xN30A
Transmit Channel Control Register - Channel 10
R/W
0x00
0xN30B
Transmit Channel Control Register - Channel 11
R/W
0x00
0xN30C
Transmit Channel Control Register - Channel 12
R/W
0x00
0xN30D
Transmit Channel Control Register - Channel 13
R/W
0x00
0xN30E
Transmit Channel Control Register - Channel 14
R/W
0x00
0xN30F
Transmit Channel Control Register - Channel 15
R/W
0x00
0xN310
Transmit Channel Control Register - Channel 16
R/W
0x00
0xN311
Transmit Channel Control Register - Channel 17
R/W
0x00
0xN312
Transmit Channel Control Register - Channel 18
R/W
0x00
0xN313
Transmit Channel Control Register - Channel 19
R/W
0x00
0xN314
Transmit Channel Control Register - Channel 20
R/W
0x00
0xN315
Transmit Channel Control Register - Channel 21
R/W
0x00
0xN316
Transmit Channel Control Register - Channel 22
R/W
0x00
0xN317
Transmit Channel Control Register - Channel 23
R/W
0x00
30
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN318
Transmit Channel Control Register - Channel 24 (E1 Applications Only)
R/W
0x00
0xN319
Transmit Channel Control Register - Channel 25 (E1 Applications Only)
R/W
0x00
0xN31A
Transmit Channel Control Register - Channel 26 (E1 Applications Only)
R/W
0x00
0xN31B
Transmit Channel Control Register - Channel 27 (E1 Applications Only)
R/W
0x00
0xN31C
Transmit Channel Control Register - Channel 28 (E1 Applications Only)
R/W
0x00
0xN31D
Transmit Channel Control Register - Channel 29 (E1 Applications Only)
R/W
0x00
0xN31E
Transmit Channel Control Register - Channel 30 (E1 Applications Only)
R/W
0x00
0xN31F
Transmit Channel Control Register - Channel 31 (E1 Applications Only)
R/W
0x00
0xN320
User (IDLE) Code Register - Channel 0
R/W
0x00
0xN321
User (IDLE) Code Register - Channel 1
R/W
0x00
0xN322
User (IDLE) Code Register - Channel 2
R/W
0x00
0xN323
User (IDLE) Code Register - Channel 3
R/W
0x00
0xN324
User (IDLE) Code Register - Channel 4
R/W
0x00
0xN325
User (IDLE) Code Register - Channel 5
R/W
0x00
0xN326
User (IDLE) Code Register - Channel 6
R/W
0x00
0xN327
User (IDLE) Code Register - Channel 7
R/W
0x00
0xN328
User (IDLE) Code Register - Channel 8
R/W
0x00
0xN329
User (IDLE) Code Register - Channel 9
R/W
0x00
0xN32A
User (IDLE) Code Register - Channel 10
R/W
0x00
0xN32B
User (IDLE) Code Register - Channel 11
R/W
0x00
0xN32C
User (IDLE) Code Register - Channel 12
R/W
0x00
0xN32D
User (IDLE) Code Register - Channel 13
R/W
0x00
0xN32E
User (IDLE) Code Register - Channel 14
R/W
0x00
0xN32F
User (IDLE) Code Register - Channel 15
R/W
0x00
0xN330
User (IDLE) Code Register - Channel 16
R/W
0x00
0xN331
User (IDLE) Code Register - Channel 17
R/W
0x00
0xN332
User (IDLE) Code Register - Channel 18
R/W
0x00
0xN333
User (IDLE) Code Register - Channel 19
R/W
0x00
0xN334
User (IDLE) Code Register - Channel 20
R/W
0x00
0xN335
User (IDLE) Code Register - Channel 21
R/W
0x00
0xN336
User (IDLE) Code Register - Channel 22
R/W
0x00
0xN337
User (IDLE) Code Register - Channel 23
R/W
0x00
31
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN338
User (IDLE) Code Register - Channel 24 (E1 Applications Only)
R/W
0x00
0xN339
User (IDLE) Code Register - Channel 25 (E1 Applications Only)
R/W
0x00
0xN33A
User (IDLE) Code Register - Channel 26 (E1 Applications Only)
R/W
0x00
0xN33B
User (IDLE) Code Register - Channel 27 (E1 Applications Only)
R/W
0x00
0xN33C
User (IDLE) Code Register - Channel 28 (E1 Applications Only)
R/W
0x00
0xN33D
User (IDLE) Code Register - Channel 29 (E1 Applications Only)
R/W
0x00
0xN33E
User (IDLE) Code Register - Channel 30 (E1 Applications Only)
R/W
0x00
0xN33F
User (IDLE) Code Register - Channel 31 (E1 Applications Only)
R/W
0x00
0xN340
Transmit Signaling Control Register - Channel 0
R/W
0x00
0xN341
Transmit Signaling Control Register - Channel 1
R/W
0x00
0xN342
Transmit Signaling Control Register - Channel 2
R/W
0x00
0xN343
Transmit Signaling Control Register - Channel 3
R/W
0x00
0xN344
Transmit Signaling Control Register - Channel 4
R/W
0x00
0xN345
Transmit Signaling Control Register - Channel 5
R/W
0x00
0xN346
Transmit Signaling Control Register - Channel 6
R/W
0x00
0xN347
Transmit Signaling Control Register - Channel 7
R/W
0x00
0xN348
Transmit Signaling Control Register - Channel 8
R/W
0x00
0xN349
Transmit Signaling Control Register - Channel 9
R/W
0x00
0xN34A
Transmit Signaling Control Register - Channel 10
R/W
0x00
0xN34B
Transmit Signaling Control Register - Channel 11
R/W
0x00
0xN34C
Transmit Signaling Control Register - Channel 12
R/W
0x00
0xN34D
Transmit Signaling Control Register - Channel 13
R/W
0x00
0xN34E
Transmit Signaling Control Register - Channel 14
R/W
0x00
0xN34F
Transmit Signaling Control Register - Channel 15
R/W
0x00
0xN350
Transmit Signaling Control Register - Channel 16
R/W
0x00
0xN351
Transmit Signaling Control Register - Channel 17
R/W
0x00
0xN352
Transmit Signaling Control Register - Channel 18
R/W
0x00
0xN353
Transmit Signaling Control Register - Channel 19
R/W
0x00
0xN354
Transmit Signaling Control Register - Channel 20
R/W
0x00
0xN355
Transmit Signaling Control Register - Channel 21
R/W
0x00
0xN356
Transmit Signaling Control Register - Channel 22
R/W
0x00
0xN357
Transmit Signaling Control Register - Channel 23
R/W
0x00
32
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN358
Transmit Signaling Control Register - Channel 24 (E1 Applications Only)
R/W
0x00
0xN359
Transmit Signaling Control Register - Channel 25 (E1 Applications Only)
R/W
0x00
0xN35A
Transmit Signaling Control Register - Channel 26 (E1 Applications Only)
R/W
0x00
0xN35B
Transmit Signaling Control Register - Channel 27 (E1 Applications Only)
R/W
0x00
0xN35C
Transmit Signaling Control Register - Channel 28 (E1 Applications Only)
R/W
0x00
0xN35D
Transmit Signaling Control Register - Channel 29 (E1 Applications Only)
R/W
0x00
0xN35E
Transmit Signaling Control Register - Channel 30 (E1 Applications Only)
R/W
0x00
0xN35F
Transmit Signaling Control Register - Channel 31 (E1 Applications Only)
R/W
0x00
0xN360
Receive Channel Control Register - Channel 0
R/W
0x00
0xN361
Receive Channel Control Register - Channel 1
R/W
0x00
0xN362
Receive Channel Control Register - Channel 2
R/W
0x00
0xN363
Receive Channel Control Register - Channel 3
R/W
0x00
0xN364
Receive Channel Control Register - Channel 4
R/W
0x00
0xN365
Receive Channel Control Register - Channel 5
R/W
0x00
0xN366
Receive Channel Control Register - Channel 6
R/W
0x00
0xN367
Receive Channel Control Register - Channel 7
R/W
0x00
0xN368
Receive Channel Control Register - Channel 8
R/W
0x00
0xN369
Receive Channel Control Register - Channel 9
R/W
0x00
0xN36A
Receive Channel Control Register - Channel 10
R/W
0x00
0xN36B
Receive Channel Control Register - Channel 11
R/W
0x00
0xN36C
Receive Channel Control Register - Channel 12
R/W
0x00
0xN36D
Receive Channel Control Register - Channel 13
R/W
0x00
0xN36E
Receive Channel Control Register - Channel 14
R/W
0x00
0xN36F
Receive Channel Control Register - Channel 15
R/W
0x00
0xN370
Receive Channel Control Register - Channel 16
R/W
0x00
0xN371
Receive Channel Control Register - Channel 17
R/W
0x00
0xN372
Receive Channel Control Register - Channel 18
R/W
0x00
0xN373
Receive Channel Control Register - Channel 19
R/W
0x00
0xN374
Receive Channel Control Register - Channel 20
R/W
0x00
0xN375
Receive Channel Control Register - Channel 21
R/W
0x00
0xN376
Receive Channel Control Register - Channel 22
R/W
0x00
0xN377
Receive Channel Control Register - Channel 23
R/W
0x00
33
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN378
Receive Channel Control Register - Channel 24
R/W
0x00
0xN379
Receive Channel Control Register - Channel 25
R/W
0x00
0xN37A
Receive Channel Control Register - Channel 26
R/W
0x00
0xN37B
Receive Channel Control Register - Channel 27
R/W
0x00
0xN37C
Receive Channel Control Register - Channel 28
R/W
0x00
0xN37D
Receive Channel Control Register - Channel 29
R/W
0x00
0xN37E
Receive Channel Control Register - Channel 30
R/W
0x00
0xN37F
Receive Channel Control Register - Channel 31
R/W
0x00
0xN380
Receive User Code Register - Channel 0
R/W
0x00
0xN381
Receive User Code Register - Channel 1
R/W
0x00
0xN382
Receive User Code Register - Channel 2
R/W
0x00
0xN383
Receive User Code Register - Channel 3
R/W
0x00
0xN384
Receive User Code Register - Channel 4
R/W
0x00
0xN385
Receive User Code Register - Channel 5
R/W
0x00
0xN386
Receive User Code Register - Channel 6
R/W
0x00
0xN387
Receive User Code Register - Channel 7
R/W
0x00
0xN388
Receive User Code Register - Channel 8
R/W
0x00
0xN389
Receive User Code Register - Channel 9
R/W
0x00
0xN38A
Receive User Code Register - Channel 10
R/W
0x00
0xN38B
Receive User Code Register - Channel 11
R/W
0x00
0xN38C
Receive User Code Register - Channel 12
R/W
0x00
0xN38D
Receive User Code Register - Channel 13
R/W
0x00
0xN38E
Receive User Code Register - Channel 14
R/W
0x00
0xN38F
Receive User Code Register - Channel 15
R/W
0x00
0xN390
Receive User Code Register - Channel 16
R/W
0x00
0xN391
Receive User Code Register - Channel 17
R/W
0x00
0xN392
Receive User Code Register - Channel 18
R/W
0x00
0xN393
Receive User Code Register - Channel 19
R/W
0x00
0xN394
Receive User Code Register - Channel 20
R/W
0x00
0xN395
Receive User Code Register - Channel 21
R/W
0x00
0xN396
Receive User Code Register - Channel 22
R/W
0x00
0xN397
Receive User Code Register - Channel 23
R/W
0x00
34
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN398
Receive User Code Register - Channel 24
R/W
0x00
0xN399
Receive User Code Register - Channel 25
R/W
0x00
0xN39A
Receive User Code Register - Channel 26
R/W
0x00
0xN39B
Receive User Code Register - Channel 27
R/W
0x00
0xN39C
Receive User Code Register - Channel 28
R/W
0x00
0xN39D
Receive User Code Register - Channel 29
R/W
0x00
0xN39E
Receive User Code Register - Channel 30
R/W
0x00
0xN39F
Receive User Code Register - Channel 31
R/W
0x00
0xN3A0
Receive Signaling Control Register - Channel 0
R/W
0x00
0xN3A1
Receive Signaling Control Register - Channel 1
R/W
0x00
0xN3A2
Receive Signaling Control Register - Channel 2
R/W
0x00
0xN3A3
Receive Signaling Control Register - Channel 3
R/W
0x00
0xN3A4
Receive Signaling Control Register - Channel 4
R/W
0x00
0xN3A5
Receive Signaling Control Register - Channel 5
R/W
0x00
0xN3A6
Receive Signaling Control Register - Channel 6
R/W
0x00
0xN3A7
Receive Signaling Control Register - Channel 7
R/W
0x00
0xN3A8
Receive Signaling Control Register - Channel 8
R/W
0x00
0xN3A9
Receive Signaling Control Register - Channel 9
R/W
0x00
0xN3AA
Receive Signaling Control Register - Channel 10
R/W
0x00
0xN3AB
Receive Signaling Control Register - Channel 11
R/W
0x00
0xN3AC
Receive Signaling Control Register - Channel 12
R/W
0x00
0xN3AD
Receive Signaling Control Register - Channel 13
R/W
0x00
0xN3AE
Receive Signaling Control Register - Channel 14
R/W
0x00
0xN3AF
Receive Signaling Control Register - Channel 15
R/W
0x00
0xN3B0
Receive Signaling Control Register - Channel 16
R/W
0x00
0xN3B1
Receive Signaling Control Register - Channel 17
R/W
0x00
0xN3B2
Receive Signaling Control Register - Channel 18
R/W
0x00
0xN3B3
Receive Signaling Control Register - Channel 19
R/W
0x00
0xN3B4
Receive Signaling Control Register - Channel 20
R/W
0x00
0xN3B5
Receive Signaling Control Register - Channel 21
R/W
0x00
0xN3B6
Receive Signaling Control Register - Channel 22
R/W
0x00
0xN3B7
Receive Signaling Control Register - Channel 23
R/W
0x00
35
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN3B8
Receive Signaling Control Register - Channel 24
R/W
0x00
0xN3B9
Receive Signaling Control Register - Channel 25
R/W
0x00
0xN3BA
Receive Signaling Control Register - Channel 26
R/W
0x00
0xN3BB
Receive Signaling Control Register - Channel 27
R/W
0x00
0xN3BC
Receive Signaling Control Register - Channel 28
R/W
0x00
0xN3BD
Receive Signaling Control Register - Channel 29
R/W
0x00
0xN3BE
Receive Signaling Control Register - Channel 30
R/W
0x00
0xN3BF
Receive Signaling Control Register - Channel 31
R/W
0x00
0xN3C0
Receive Substitution Signaling Register - Channel 0
R/W
0x00
0xN3C1
Receive Substitution Signaling Register - Channel 1
R/W
0x00
0xN3C2
Receive Substitution Signaling Register - Channel 2
R/W
0x00
0xN3C3
Receive Substitution Signaling Register - Channel 3
R/W
0x00
0xN3C4
Receive Substitution Signaling Register - Channel 4
R/W
0x00
0xN3C5
Receive Substitution Signaling Register - Channel 5
R/W
0x00
0xN3C6
Receive Substitution Signaling Register - Channel 6
R/W
0x00
0xN3C7
Receive Substitution Signaling Register - Channel 7
R/W
0x00
0xN3C8
Receive Substitution Signaling Register - Channel 8
R/W
0x00
0xN3C9
Receive Substitution Signaling Register - Channel 9
R/W
0x00
0xN3CA
Receive Substitution Signaling Register - Channel 10
R/W
0x00
0xN3CB
Receive Substitution Signaling Register - Channel 11
R/W
0x00
0xN3CC
Receive Substitution Signaling Register - Channel 12
R/W
0x00
0xN3CD
Receive Substitution Signaling Register - Channel 13
R/W
0x00
0xN3CE
Receive Substitution Signaling Register - Channel 14
R/W
0x00
0xN3CF
Receive Substitution Signaling Register - Channel 15
R/W
0x00
0xN3D0
Receive Substitution Signaling Register - Channel 16
R/W
0x00
0xN3D1
Receive Substitution Signaling Register - Channel 17
R/W
0x00
0xN3D2
Receive Substitution Signaling Register - Channel 18
R/W
0x00
0xN3D3
Receive Substitution Signaling Register - Channel 19
R/W
0x00
0xN3D4
Receive Substitution Signaling Register - Channel 20
R/W
0x00
0xN3D5
Receive Substitution Signaling Register - Channel 21
R/W
0x00
0xN3D6
Receive Substitution Signaling Register - Channel 22
R/W
0x00
0xN3D7
Receive Substitution Signaling Register - Channel 23
R/W
0x00
36
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
0xN3D8 0xN3FF
Reserved
0xN400 0xN4FF
Reserved
TYPE
DEFAULT
VALUE
R/O
0x00
TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN500
Receive Signaling Register Array - Channel 0
R/O
0x00
0xN501
Receive Signaling Register Array - Channel 1
R/O
0x00
0xN502
Receive Signaling Register Array - Channel 2
R/O
0x00
0xN503
Receive Signaling Register Array - Channel 3
R/O
0x00
0xN504
Receive Signaling Register Array - Channel 4
R/O
0x00
0xN505
Receive Signaling Register Array - Channel 5
R/O
0x00
0xN506
Receive Signaling Register Array - Channel 6
R/O
0x00
0xN507
Receive Signaling Register Array - Channel 7
R/O
0x00
0xN508
Receive Signaling Register Array - Channel 8
R/O
0x00
0xN509
Receive Signaling Register Array - Channel 9
R/O
0x00
0xN50A
Receive Signaling Register Array - Channel 10
R/O
0x00
0xN50B
Receive Signaling Register Array - Channel 11
R/O
0x00
0xN50C
Receive Signaling Register Array - Channel 12
R/O
0x00
0xN50D
Receive Signaling Register Array - Channel 13
R/O
0x00
0xN50E
Receive Signaling Register Array - Channel 14
R/O
0x00
0xN50F
Receive Signaling Register Array - Channel 15
R/O
0x00
0xN510
Receive Signaling Register Array - Channel 16
R/O
0x00
0xN511
Receive Signaling Register Array - Channel 17
R/O
0x00
0xN512
Receive Signaling Register Array - Channel 18
R/O
0x00
0xN513
Receive Signaling Register Array - Channel 19
R/O
0x00
0xN514
Receive Signaling Register Array - Channel 20
R/O
0x00
0xN515
Receive Signaling Register Array - Channel 21
R/O
0x00
0xN516
Receive Signaling Register Array - Channel 22
R/O
0x00
0xN517
Receive Signaling Register Array - Channel 23
R/O
0x00
0xN518
Receive Signaling Register Array - Channel 24
R/O
0x00
ADDRESS LOCATION
37
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
ADDRESS LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN519
Receive Signaling Register Array - Channel 25
R/O
0x00
0xN51A
Receive Signaling Register Array - Channel 26
R/O
0x00
0xN51B
Receive Signaling Register Array - Channel 27
R/O
0x00
0xN51C
Receive Signaling Register Array - Channel 28
R/O
0x00
0xN51D
Receive Signaling Register Array - Channel 29
R/O
0x00
0xN51E
Receive Signaling Register Array - Channel 30
R/O
0x00
0xN51F
Receive Signaling Register Array - Channel 31
R/O
0x00
0xN520 - 0xN59F Reserved
0xN5A0
Receive Signaling Control Registers - Channel 0
R/W
0x00
0xN5A1
Receive Signaling Control Registers - Channel 1
R/W
0x00
0xN5A2
Receive Signaling Control Registers - Channel 2
R/W
0x00
0xN5A3
Receive Signaling Control Registers - Channel 3
R/W
0x00
0xN5A4
Receive Signaling Control Registers - Channel 4
R/W
0x00
0xN5A5
Receive Signaling Control Registers - Channel 5
R/W
0x00
0xN5A6
Receive Signaling Control Registers - Channel 6
R/W
0x00
0xN5A7
Receive Signaling Control Registers - Channel 7
R/W
0x00
0xN5A8
Receive Signaling Control Registers - Channel 8
R/W
0x00
0xN5A9
Receive Signaling Control Registers - Channel 9
R/W
0x00
0xN5AA
Receive Signaling Control Registers - Channel 10
R/W
0x00
0xN5AB
Receive Signaling Control Registers - Channel 11
R/W
0x00
0xN5AC
Receive Signaling Control Registers - Channel 12
R/W
0x00
0xN5AD
Receive Signaling Control Registers - Channel 13
R/W
0x00
0xN5AE
Receive Signaling Control Registers - Channel 14
R/W
0x00
0xN5AF
Receive Signaling Control Registers - Channel 15
R/W
0x00
0xN5B0
Receive Signaling Control Registers - Channel 16
R/W
0x00
0xN5B1
Receive Signaling Control Registers - Channel 17
R/W
0x00
0xN5B2
Receive Signaling Control Registers - Channel 18
R/W
0x00
0xN5B3
Receive Signaling Control Registers - Channel 19
R/W
0x00
0xN5B4
Receive Signaling Control Registers - Channel 20
R/W
0x00
0xN5B5
Receive Signaling Control Registers - Channel 21
R/W
0x00
0xN5B6
Receive Signaling Control Registers - Channel 22
R/W
0x00
0xN5B7
Receive Signaling Control Registers - Channel 23
R/W
0x00
38
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
TYPE
DEFAULT
VALUE
0xN600 - 0xN640 LAPD Buffer 0 Control Register (64-Bytes)
R/W
0x00
0xN700 - 0xN740 LAPD Buffer 1 Control Register (64-Bytes)
R/W
0x00
ADDRESS LOCATION
REGISTER NAME
0xN5B8 - 0xN5FF Reserved
0xN741 - 0xN8FF Reserved
TABLE 23: T1/E1 PERFORMANCE MONITOR REGISTER (WHERE N RANGES VALUE FROM 0X01 TO 0X38)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xN900
T1 Receive Line Code Violation Count Register (MSB)
RUR
0x00
0xN901
T1 Receive Line Code Violation Count Register (LSB)
RUR
0x00
0xN902
T1/E1 Receive Frame Alignment Error Count Register - MSB
RUR
0x00
0xN903
T1/E1 Receive Frame Alignment Error Count Register (LSB)
RUR
0x00
0xN904
T1/E1 Receive Severely Erred Frame Count Register
RUR
0x00
0xN905
T1/E1 Receive Synchronization Bit Error Count Register - MSB
RUR
0x00
0xN906
T1/E1 Receive Synchronization Bit Error Count Register - LSB
RUR
0x00
0xN907
T1/E1 Receive FEBE Event Count Register - MSB
RUR
0x00
0xN908
T1/E1 Receive FEBE Event Count Register - LSB
RUR
0x00
0xN909
T1/E1 Receive Slip Event Count Register
RUR
0x00
0xN90A
T1/E1 Receive Loss of Frame Count Register
RUR
0x00
0xN90B
T1/E1 Receive Change of Frame Count Register
RUR
0x00
0xN90C
LAPD Frame Check Sequence Error Count Register
RUR
0x00
0xN90D
T1/E1 PRBS Bit Error Count Register - MSB
RUR
0x00
0xN90E
T1/E1 PRBS Bit Error Count Register - LSB
RUR
0x00
0xN90F
T1/E1 Transmit Slip Event Count Register
RUR
0x00
0xN910 - 0xNAFF Reserved
TABLE 24: T1/E1 FRAMER BLOCK INTERRUPT REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xNB00
T1/E1 Framer Block Interrupt Enable Register
R/W
0x00
0xNB01
T1/E1 Framer Block Interrupt Status Register
R/O
0x00
0xNB02
Alarm and Error Status Register
RUR
0x00
0xNB03
Alarm and Error Interrupt Enable Register
R/W
0x00
39
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 24: T1/E1 FRAMER BLOCK INTERRUPT REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xNB04
Framer Interrupt Enable Register
R/W
0x00
0xNB05
Framer Interrupt Status Register
RUR
0x00
0xNB06
Data Link Interrupt Status Register
RUR
0x00
0xNB07
Data Link Interrupt Enable Register
0xNB0A
Receive Loop Back Code Interrupt & Status Register - Code 0
R/W
0x00
0xNB0B
Receive Loop Back Code Interrupt Enable Register - Code 0
R/W
0x00
0xNB0C - 0xNB0D Reserved
0xNB0E
Excessive Zero Interrupt Status Register
RUR
0x00
0xNB0F
Excessive Zero Interrupt Enable Register
RUR
0x00
0xNB10
Receive Sa Interrupt Enable Register (E1 Applications)SS7 Interrupt Status Register - LAPD # 1 (T1 Applications)
R/W
0x00
0xNB11
Receive Sa Interrupt Enable Register (E1 Applications)SS7 Interrupt
Enable Register - LAPD # 1 (T1 Applications)
R/W
0x00
0xNB12 - 0xNB13 Reserved
0xNB14
Receive Loop-back Code Interrupt Status Register - Code 1
RUR
v0x00
OxNB15
Receive Loop-back Code Interrupt Enable Register - Code 1
R/W
0x00v
0x00
0xNB16 - 0xNB17 Reserved
0xNB18
SS7 Interrupt Status Register - LAPD # 2 (T1 Applications)
R/W
0xNB19
SS7 Interrupt Enable Register - LAPD # 2 (T1 Applications)
R/W
0xNB1A
Receive Loop-back Code Interrupt Status Register - Code 2
RUR
0x00
0xNB1B
Receive Loop-back Code Interrupt Enable Register - Code 2
R/W
0x00
0xNB1C - 0xNB27 Reserved
0xNB28
SS7 Interrupt Status Register - LAPD # 3 (T1 Applications)
R/W
0x00
0xNB29
SS7 Interrupt Enable Register - LAPD # 3 (T1 Applicaions)
R/W
0x00
0xNB30 - 0xNB3F Reserved
0xNB40
Customer Installation Alarm Status Register
RUR
0x00
0xNB41
Customer Installation Alarm Interrupt Enable Register
R/W
0x00
R/O
0x00
0xNB42 - 0xNCFF Reserved
40
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 25: VT MAPPER REGISTER (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xND42
Channel Control - VT Mapper Block - Ingress Direction - DS1/E1 Insertion
Control Register - Byte 1
R/O & R/W
0x00
0xND43
Channel Control - VT-Mapper Block - Ingress Direction - DS1/E1 Insertion
Control Register - Byte 0
R/W
0x00
0xND44
Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop
Control Register - Byte 3
R/W
0x00
0xND45
Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop
Control Register - Byte 2
R/W
0x00
0xND46
Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop
Control Register - Byte 1
R/O
0x10
0xND47
Channel Control - VT De-Mapper Block - Egress Direction - DS1/E1 Drop
Control Register - Byte 0
R/O & R/W
0x00
0xND00 - 0xND41 Reserved
0xND48 - 0xND49 Reserved
0xND4A
Channel Control - VT De-Mapper Block - Egress Direction - BIP-2 Error
Count Register - Byte 1
RUR
0x00
0xND4B
Channel Control - VT De-Mapper Block - Egress Direction - BIP-2 Error
Count Register - Byte 0
RUR
0x00
0xND4C - 0xND4D Reserved
0xND4E
Channel Control - VT De-Mapper Block - Egress Direction - REI-V Event
Count Register - Byte 1
RUR
0x00
0xND4F
Channel Control - VT-De-Mapper Block - Egress Direction - REI-V Event
Count Register - Byte 0
RUR
0x00
R/W
0x00
0xND50 - 0xND52 Reserved
0xND53
Channel Control - VT-De-Mapper Block - Egress Direction - Receive APS
Register - Byte 0
0xND54 - 0xND55 Reserved
0xND56
Channel Control - VT-Mapper Block - Ingress Direction - Transmit APS
Register - Byte 1
R/W
0x00
0xND57
Channel Control - VT-Mapper Block - Ingress Direction - Transmit APS/K4
Register - Byte 0
R/W
0x00
0xND58 - 0xND62 Reserved
0xND63
Channel Control - VT-De-Mapper Block- Egress Direction - J2 Byte Status
Register - Byte 0
R/O
0x00
0xND64
Channel Control - VT-De-Mapper Block - Egress Direction - Composite
Status Register - Byte 1
RUR
0x00
0xND65
Channel Control - VT-De-Mapper Block - Egress Direction -Composite Status Register - Byte 0
RUR
0x00
41
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 25: VT MAPPER REGISTER (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
ADDRESS
LOCATION
REGISTER NAME
TYPE
DEFAULT
VALUE
0xND66
Reserved
RUR
0x00
0xND67
Channel Control - VT-De-Mapper Block - Egress Direction - Interrupt Status Register - Byte 0
RUR
0x00
0xND68
Channel Control - VT-De-Mapper Block - Egress Direction - Interrupt
Enable Register
R/W
0x00
0xND69
Channel Control - VT-De-Mapper - Block - Egress Direction - Interrupt
Enable Register
R/W
0x00
0xND6A
Reserved
R/W
0x00
0xND6B
Channel Control - VT-De-Mapper Block - Egress Direction -Interrupt
Enable Register - Byte 0
R/W
0x00
0xND6C - 0xND70 Reserved
0xND71
Channel Control - VT-De-Mapper Block - Egress Direction - VT Path Trace
Buffer Control Register
R/W
0x00
0xND72
Channel Control - VT-De-Mapper Block - Egress Direction - Auto AIS Control Register - Byte 1
R/W
0x00
0xND73
Channel Control VT De-Mapper Block - Egress Direction - Auto AIS Control Register - Byte 0
R/W
0x00
0xND74 - 0xND75 Reserved
0xND76
Channel Control - VT-Mapper Block - Ingress Direction - Transmit J2 Byte
Value Register
R/W
0x00
0xND77
Channel Control - VT Mapper Block - Ingress Direction - Transmit N2 Byte
Value Register
R/W
0x00
2.0 REGISTER DESCRIPTIONS
the remainder of this document use register descriptions with the folowing format:
8-BIT register table
TABLE 26: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Bit Name
Bit Name
Bit Name
Bit Name
Bit Name
Bit Name
Bit Name
Bit Name
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT descriptions
BIT 7 - Bit name
Bit Description
` 0 - Logic LOW condition
` 1 - Logic HIGH condition
NOTE: Speial notes
BIT [6:0] - Bit name
42
PRELIMINARY
REV. P1.0.6
2.1
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
OPERATION CONTROL REGISTERS
TABLE 27: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Ingress
Direction
Add-Drop
Interface
Enable
Egress
Direction
Add-Drop
Interface
Enable
Parallel
Interface
Enable
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Mode_Select[3:0]
BIT7 - Unused
BIT6 - Ingress Direction Add-Drop Interface Enable:
This READ/WRITE bit-field is used to either enable or disable the Ingress Direction Add-Drop Interface.
If the Ingress Direction Add-Drop Interface is enabled, then the Ingress Direction Drop Port will drop out the entire traffic
(of all 28 channels in the Ingress Direction) via the IG_TE1RxDATA[7:0] output pins. Additionally, the user can add in
of the 28 DS1 or 21 E1 Ingress Direction signals via the Ingress Direction Add Port.
` 0 - Disables the Ingress Direction Add-Drop Interface.
` 1 - Enables the Ingress Direction Add-Drop Interface.
NOTE: This feature is only available if the XRT86SH328 has been configured to operate in either of the following
modes.·
•
The VT-Mapper Mode (w/ T1/E1 Framing)
•
The M13 MUX Mode (w/ T1/E1 Framing)
•
The M13 MUX to STS-1/STS-3 Mode
•
The Transmux Mode
BIT 5 - Egress Direction Add-Drop Interface Enable:
This READ/WRITE bit-field is used to either enable or disable the Egress Direction Add-Drop Interface.
If the user enables the Egress Direction Add-Drop Interface, then the Egress Direction Drop Port will drop out the entire
traffic (of all 28 channels in the Egress Direction) via the EG_TE1RxDATA[7:0] output pins. Additionally, the user can
add in any of the 28 DS1 or 21 E1 Egress Direction signals via the Egress Direction Add Interface.
` 0 - Disables the Egress Direction Add-Drop Interface.
` 1 - Enables the Egress Direction Add-Drop Interface.
NOTE: This feature is only available if the XRT86SH328 has been configured to operate in either of the following
modes.
•
The VT-Mapper Mode (w/ T1/E1 Framing)
•
The M13 MUX Mode (w/ T1/E1 Framing)
•
The M13 MUX to STS-1/STS-3 Mode
•
The Transmux Mode
BIT 4 - Parallel Interface Enable
NOTE: This bit-field is only valid if the XRT86SH328 has been configured to operate in the 28-Channel DS1/E1 Framer
& LIU Mode.
BIT[3:0] - Mode Select Bits[3:0]:
These four READ/WRITE bit-fields are used to select the mode that the XRT86SH328 will operate in, as shown in the
table below below.
43
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Mode Select Bits
MODE_SELECT[3:0]
RESULTING MODE OF OPERATION
0000
VT-Mapper Mode (w/ T1/E1 Framing)
0001
M13 MUX Mode (w/ T1/E1 Framing
0010
M13 MUX to STS-1/STS-3 Mode
0011
Reserved
0100
28 Channel T1/E1 Framer & LIU Mode
0101
Transmux Mode (w/ T1/E1 Framing)
0110 & 0111
Reserved
1000
VT-Mapper Mode (w T1/E1 Framers by-passed)
1001
M13 MUX Mode (w/ T1/E1 Framers by-passed)
1010
M13 MUX to STS-1/STS-3 Mode (w/ T1/E1 Framers by-passed)
1011
Reserved
1100
28 Channel T1/E1 LIU Mode
1101
Transmux Mode (w/ T1/E1 Framers by-passed)
TABLE 28: OPERATION CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0001)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
Interrupt
Write
Clear/RUR
Enable
Interrupt
Clear
Interrupt
Enable
R/O
R/O
R/O
R/O
R/O
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:3] - Unused
Please set to 0 for normal operation.
BIT 2 - Interrupt Write to Clear/RUR
This READ/WRITE bit-field is used to configure all of the Source-Level Interrupt Status bits (within the XRT86SH328)
to either be Write to Clear (WTC) or Reset-upon-Read (RUR) bits.
` 0 - Configures all Source-Level Interrupt Status register bits to function as Reset-upon-Read (RUR).
` 1 - Configures all Source-Level Interrupt Status register bits to function as Write-to-Clear (WTC)
BIT 1 - Enable Interrupt Clear
This READ/WRITE bit-field is used to configure the XRT94L43 to automatically disable all interrupts that are activated.
` 0 - Configures the chip to NOT automatically disable any Interrupts following their activation.
` 1 - Configures the chip to automatically disable all Interrupts following their activation.
BIT 0 - Interrupt Enable
This READ/WRITE bit-field is used to configure the XRT94L43 to generate interrupt requests to the Microprocessor.
` 0 - Configures the chip to NOT generate interrupt to the Microprocessor.
All interrupts are disabled and the Microprocessor must poll the register bits.
` 1 - Configures the chip to generate interrupts to the Microprocessor.
44
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: To operate the XRT986SH328 in an Interrupt-Driven Manner, this bit-field must be set to a logic 1.
TABLE 29: OPERATION CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0003)
BIT7
BIT6
BIT 5
BIT 4
Reserved
Receive
Clock Detect
R/W
R/W
R/O
R/O
R/W
R/O
R/O
R/W
0
1
0
0
0
0
0
0
Reserved
BIT 3
BIT 2
Burst Enable
BIT 1
Reserved
BIT 0
SWRESET
BIT7 - Reserved
BIT6 - Receive Clock Detect
This READ/WRITE bit-field is used to enable or disable the Receive Clock Detect feature. If this feature is enabled, then
the Receive STS-1/STS-3 circuitry will check for the existence of the 6.48MHz or 19.44MHz clock signal (through the
Receive STS-1/STS-3 Telecom Bus Interface). If none of these clock signals are present, then the Receive STS-1/STS-3
TOH Processor block and each of the 1 (or 3) Receive SONET POH Processor block circuitry will automatically switch over
and use the 19.44MHz clock signal that is applied to the Tx19_51MHz input pin (Ball R3) as there timing source.
` 0 - Disables the Receive Clock Detect feature.
` 1 - Enables the Receive Clock Detect feature.
BIT [5:4] = Reserved
BIT 3 - Burst Enable
This READ/WRITE bit-field is used to either enable or disable Burst Mode operation within the Microprocessor Interface.
` 0 - Disables Burst Mode operation.
` 1 - Enables Burst Mode operation
BIT 2 - BIT 1 - Reserved
BIT 0 - SWReset - SONET Block
This READ/WRITE bit-field is used to command a software reset to the SONET/SDH block. If a software reset to the
SONET/SDH blocks is invoked, then all of the internal state machines will be reset to their default conditions and each
of the following blocks will undergo a re-frame operation.
•
The Receive STS-1/3 TOH Processor block
•
Each of the three (3) Receive SONET POH Processor blocks
•
Each of the three (3) VT Mapper Blocks
A 0 to 1 transition, within this bit-field commands this Software Reset.
NOTE: This Software Reset does not reset the command registers to their default state. This can only be achieved by
executing a Hardware RESET (e.g., by pulling the RESET_L* input pin LOW).
TABLE 30: DEVICE ID VALUE REGISTER - BYTE 3 (ADDRESS = 0X0004)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Device ID Value
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
1
0
1
0
0
0
0
BIT [7:0] - Device ID Value
This READ-ONLY bit-field is set to the value 0x50 and is used's software code to uniquely identify this device as being the
XRT86SH328.
45
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 31: REVISION NUMBER VALUE REGISTER - BYTE 2 (ADDRESS = 0X0005)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Revision Number Value
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
1
BIT [7:0] - Revision Number Value
This READ-ONLY bit-field is set to the value that corresponds to its revision number. Revision A silicon will be set to
the value 0x01. This register is uses software code to uniquely identify the revision number of this device
TABLE 32: OPERATION INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X000B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
BIT 0
TB Parity Error
Interrupt Status
R/O
R/O
R/O
R/O
R/O
R/O
R/O
RUR/WTC
0
0
0
0
0
0
0
0
BIT [7:1] - Unused
Please set to 0 for normal operation
BIT 0 - Telecom Bus Parity Error Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of 51.84/155.52Mbps Telecom Bus - Parity
Error interrupt has occurred since the last read of this register bit.
` 0 - Indicates that the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt has NOT occurred since
the last read of this register bit.
` 1 - Indicates that the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt has occurred since the last
of this register bit.
NOTE: This register bit is only active if the XRT86SH328 has been configured to operate in the Telecom Bus Mode.
TABLE 33: OPERATION INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X000F)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
BIT 0
Telecom BusParity
Error Interrupt
Enable
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/W
0
0
0
0
0
0
0
0
BIT [7:1] - Unused
Please set to 0 for normal operation
BIT 0 - Telecom Bus Parity Error Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of 51.84/155.52Mbps Telecom Bus - Parity
Error interrupt.
` 0 - Disables the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt.
` 1 - Enables the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt.NOTE: This register bit is only
active if the XRT86SH328 has been configured to operate in the Telecom Bus Mode.
46
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 34: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS = 0X0012)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Op Control
Block
Interrupt
Status
DS3 Mapper
Block
Interrupt
Status
VT Mapper
Block
Interrupt
Status
DS1/E1
Framer/LIU
Block
(VT Side)
Interrupt
Status
DS1/E1
Framer/LIU
Block
(M13 Side)
Interrupt
Status
DS3/E3
Framer
Block
nterrupt
Status
Receive
Line
Interface
Block
Interrupt
Status
Transmit
Line
Interface
Block
Interrupt
Status
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - Operation Control Block Interrupt Status
This READ-ONLY bit-field indicates whether or not an Operation Control Block-related Interrupt is awaiting service.
` 0 - No Operation Control Block Interrupts are awaiting service.
` 1 - At least one Operation Control Block Interrupt is awaiting service.
BIT 6- DS3 Mapper Block Interrupt Status
This READ-ONLY bit-field indicates whether or not a Mapper Block-related Interrupt is awaiting service.
` 0 - No Mapper Block interrupt is awaiting service.
` 1 - At least one Mapper Block Interrupt is awaiting service.
BIT 5 - VT Mapper Block Interrupt Status
This READ-ONLY bit-field indicates whether or not a VT-Mapper block interrupt is awaiting service.
` 0 - Indicates that no VT Mapper block interrupt is awaiting service.
` 1 - Indicates that at least one VT Mapper block interrupt is awaiting service.
BIT 4 - DS1/E1 Framer/LIU Block (VT Side) Interrupt Status
This READ-ONLY bit-field indicates whether or not a DS1/E1 Framer/LIU Block (on the VT Side) Interrupt is awaiting
service.
` 0 - Indicates that no DS1/E1 Framer Block (VT Side) interrupt is awaiting service.
` 1 - At least one DS1/E1 Framer/LIU Block (VT Side) interrupt is awaiting service.
BIT 3 - DS1/E1 Framer/LIU Block (M13 Side) Interrupt Status
This READ-ONLY bit-field indicates whether or not a DS1/E1 Framer/LIU Block (M13 Side) Interrupt is awaiting service.
` 0 - No DS1/E1 Framer/LIU Block (M13 Side) interrupt is awaiting service.
` 1 - At least one DS1/E1 Framer/LIU (M13 Side) interrupt is awaiting service.
BIT 2 - DS3/E3 Framer Block Interrupt Status
This READ-ONLY bit-field indicates whether or not a DS3/E3 Framer Block interrupt is awaiting service.
` 0 - No DS3/E3 Framer block interrupt is awaiting service.
` 1 - At least one DS3/E3 Framer block interrupt is awaiting service.
BIT 1:0 - Unused
47
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 35: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0013)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
Receive
STS-1/STS-3
TOH Block
Interrupt
Status
Receive
STS-1/STS-3 POH
Block
Interrupt
Status
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Unused
BIT 2
BIT 1
External
Interrupt Status # 1
BIT 0
Unused
BIT 7 - Unused
BIT 6 - Receive STS-1/ST3-3TOH Processor Block Interrupt Status
This READ-ONLY bit-field indicates whether or not a Receive STS-1/STS-3 TOH Processor Block interrupt is awaiting
service.
` 0 - No Receive STS-1/STS-3 TOH Processor Block Interrupt is awaiting service.
` 1 - At least one Receive STS-1/STS-3 TOH Processor Block interrupt is awaiting service.
BIT 5 - Receive STS-1/STS-3 POH Processor Block Interrupt Status
This READ-ONLY bit-field indicates whether or not a Receive STS-1/STS-3 POH Processor Block interrupt is awaiting
service.
` 0 - No Receive STS-1/STS-3 POH Processor Block Interrupt is awaiting service.
` 1 - At least one Receive STS-1/STS-3 POH Processor Block Interrupt is awaiting service.
BIT [4:3] - Unused
BIT 2 - External Interrupt Input Pin # 1 - Interrupt Status
This READ-ONLY bit-field indicates whether or not an External Interrupt Input Pin # 1 Interrupt is awaiting service, as
described below.
` 0 - No External Interrupt Input Pin # 1 Interrupt is awaiting service.
` 1 - The External Interrupt Input Pin # 1 Interrupt is awaiting service.
NOTE: If this interrupt is enabled, then the XRT86SH328 will generate this interrupt anytime that the EXT_INT_1 Input
pin (Ball T5) has been driven to the logic HIGH level.
BIT [1:0] - Unused
TABLE 36: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS = 0X0016)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Op Control
Block
Interrupt
Enable
DS3Mapper
Block
Interrupt
Enable
VT Mapper
Block
Interrupt
Enable
DS1/E1
Framer/LIU
Block
(VT Side)
Interrupt
Enable
DS1/E1
Framer/LIU
Block
(M13 Side)
Interrupt
Enable
DS3Framer
Block
nterrupt
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/O
0
0
0
0
0
0
0
0
Unused
BIT 7 - Operation Control Block Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Operation Control Block for interrupt generation. If a
0 is written to this register bit and if the Operation Control Block (for interrupt generation) is disabled, then all Operation
Control Block interrupts will be disabled for interrupt generation.
If a 1 is written to this register bit, the individual Operation Control Block interrupt(s) at the Source Level will still need
48
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
to be enabled in order to enable that particular interrupt
` .0 - Disable all Operation Control Block interrupts within the device.
` 1 - Enables the Operation Control Block at the Block-Level for interrupt generation
BIT 6 - DS3 Mapper Block Interrupt Enable
This READ/WRITE bit is used to either enable or disable the DS3 Mapper Block for interrupt generation. If a 0 is written
to this register bit and if the DS3 Mapper Block (for interrupt generation) is disabled, then all DS3 Mapper Block
interrupts will be disabled for interrupt generation.
If a 1is written to this register bit, the individual DS3 Mapper Block interrupt(s) at the Source Levelwill still need to be
enabled in order to enable that particular interrupt.
` 0 - Disable all DS3 Mapper Block interrupts within the device.
` 1 - Enables the DS3 Mapper Block interrupts at the Block-Level
BIT 5 - VT Mapper Block Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the VT-Mapper Block for interrupt generation. If the user
writes a 0 into this register bit and disables the VT Mapper Block (for interrupt generation) then all VT-Mapper Block
interrupts will be disabled for interrupt generation.
If the user writes a 1 into this register bit, the user will still need to enable the individual VT-Mapper Block Interrupt(s)
at the Source Level in order to enable that particular interrupt.
` 0 - Disables all VT Mapper Block Interrupts within the device.
` 1 - Enables the VT Mapper Block Interrupts at the Block-Level
BIT 4- DS1/E1 Framer/LIU Block (VT Side) Interrupt Enable
This READ/WRITE bit is used to either enable or disable the DS1/E1 Framer/LIU Block (on the VT Side) for interrupt
generation.
If the user writes a 0 to this register bit and disables the DS1/E1 Framer/LIU Block (on the VT Side) for interrupt
generation, then all DS1/E1 Framer/LIU Block interrupts will be disabled for interrupt generation.
If the user writes a 1 to this register bit, the user will still need to enable the individual DS1/E1 Framer/LIU Block
interrupt(s) at the Source Level in order to enable that particular interrupt.
` 0 - Disable all DS1/E1 Framer/LIU Block interrupts within the device.
` 1 - Enables the DS1/E1 Framer/LIU Block at the Block-Level.
BIT 3 - DS1/E1 Framer/LIU Block (M13 Side) Interrupt Enable
This READ/WRITE bit is used to either enable or disable the DS1/E1 Framer/LIU Block (on the M13 Side) for interrupt
generation.
If the user writes a 0 to this register bit and disables the DS1/E1 Framer/LIU Block (for interrupt generation), then all
DS1/E1 Framer/LIU Block interrupts will be disabled for interrupt generation.
If the user writes a 1 to this register bit, the user will still need to enable the individual DS1/E1 Framer/LIU Block
interrupt(s) at the Source Level in order to enable that particular interrupt.
` 0 - Disable all DS1/E1 Framer/LIU Block interrupts within the device,
` 1 - Enables the DS1/E1 Framer/LIU Block interrupts at the Block-Level.
BIT 2 - DS3 Framer Block Interrupt Enable
This READ/WRITE bit is used to either enable or disable the DS3 Framer Block for interrupt generation.
If the user writes a 0 to this register bit and disables the DS3 Framer Block (for interrupt generation), then all DS3
Framer Block interrupts will be disabled for interrupt generation. If the user writes a 1 to this register bit, the user will
still need to enable the individual DS3 Framer Block interrupt(s) at the Source Level in order to enable that particular
interrupt.
` 0 - Disable all DS3 Framer Block interrupts within the device.
` 1 - Enables the DS3 Framer Block at the Block-Level.
BIT [1:0] - Unused
49
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 37: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0017)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
Receive
STS-1/STS-3
TOHBlock
Interrupt
Enable
Receive
STS-1 POH
Block
Interrupt
Enable
R/O
R/W
R/W
R/O
R/O
R/W
R/W
R/O
0
0
0
0
0
0
0
0
Unused
BIT 2
BIT 1
External
Interrupt
Enable # 1
BIT 0
Unused
BIT 7 - Unused
BIT 6 - Receive STS-1/STS-3 TOH Processor Block Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Receive STS-1/STS-3 TOH Processor Block for
interrupt generation.
If the user writes a 0 to this register bit and disables the Receive STS-1/STS-3 TOH Processor Block (for interrupt
generation), then all Receive STS-1/STS-3 TOH Processor Block interrupts will be disabled for interrupt generation.
If the user writes a 1 to this register bit, the user will still need to enable the individual Receive STS-1/STS-3 TOH
Processor Block interrupt(s) at the Source Level in order to enable that particular interrupt.
` 0 - Disables all Receive STS-1/STS-3 TOH Processor Block interrupts within the device.
` 1 - Enables the Receive STS-1/STS-3 TOH Processor Block at the Block Level for interrupt generation.
BIT 5 - Receive STS-1/STS-3 POH Processor Block Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Receive STS-1/STS-3 POH Processor Block for
interrupt generation.
If the user writes a 0 into this register bit and disables the Receive STS-1/STS-3 POH Processor Block (for interrupt
generation), then all Receive STS-1/STS-3 Processor Block interrupts will be disabled for interrupt generation.
If the user writes a 1 to this register bit, then the user will still need to enable the individual Receive STS-1/STS-3 POH
Processor Block Interrupt(s) at the Source Level in order to enable that particular interrupt.
` 0 - Disables all Receive STS-1/STS-3 POH Processor Block Interrupts within the device.
` 1 - Enables the Receive STS-1/STS-3 POH Processor Block at the Block Level for interrupt generation.
BIT [4:3] - Unused
BIT 2 - External Interrupt Input Pin # 1 - Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the External Interrupt Pin # 1 Interrupt.
If this interrupt is enabled, then the XRT86SH328 will generate an interrupt anytime that the EXT_INT_1 input pin (Ball
T5) has been driven to the logic HIGH level.
` 0 - Disables the External Interrupt Input # 1 Interrupt
` 1 - Enables the External Interrupt Input # 1 Interrupt.
BIT [1:0] - Unused
50
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 38: MODE CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
T1/E1
De-Sync
Disable
STS-1/STS-3
& DS3
Share Serial
Interface
Additional
T1/E1
Framers
Enabled
R/W
R/W
R/W
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Unused
BIT 0
AU-3/TUG_3*
BIT 7 - T1/E1 De-Sync Disable
This READ/WRITE bit-field is used to either enable or disable the T1/E1 De-Sync Circuitry within the XRT86SH328.
` 0 - Enables the T1/E1 De-Sync Circuitry.
` 1 - Disables the T1/E1 De-Sync Circuitry.
BIT 6 - STS-1/STS-3 and DS3 Share Serial Interface
This READ/WRITE bit-field is used to configure the DS3 and STS-1/STS-3 circuitry to either share the same Serial
Interface or not. To operate the XRT86SH328 in the Transmux mode, then the user must configure the DS3 and STS1/STS-3 circuitry to NOT share the same Serial Interface.
` 0 - Configures the STS-1/STS-3 and DS3 circuitry to NOT share the same Serial Interface.
` 1 - Configures the STS-1/STS-3 and DS3 circuitry to Share the same Serial Interface.
BIT 5 - Additional T1/E1 Framer Enabled
This READ/WRITE bit-field is used to either enable or disable the M13 T1/E1 Framers.
If the user enables these additional T1/E1 Framers, then the XRT86SH328 will be able to perform full-blown
performance monitoring in both the Ingress and Egress Directions
.If the user disables the M13 T1/E1 Framers, then the user will only be able to perform full-block performance monitoring
on the Ingress Direction T1/E1 signals.
` 0 - Disables the M13 T1/E1 Framer blocks.
` 1 - Enables the M13 T1/E1 Framer blocks.
NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in the 28-Channel Clear-Channel
T1/E1 Framer Mode.
BIT [4:1] - Unused
BIT 0 - AU-3/TUG-3 Mode Select:
This READ/WRITE bit-field is used to configure the XRT86SH328 to operate in either the AU-3 or the TUG-3 Mapping
Mode.
` 0 - Configures the XRT86SH328 to operate in the TUG-3 Mode.
` 1 - Configures the XRT86SH328 to operate in the AU-3 Mode.
NOTE: This register bit is only active if the XRT86SH328 has been configured to operate in the SDH Mode.
TABLE 39: LOOP-BACK CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001F)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
Loop-back[3:0]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4]- Unused
BIT [3:0] - Loop-back Mode[3:0]
51
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
These four READ/WRITE bits-fields are used to configure the XRT86SH328 to operate in a variety of loop-back modes,
as is tabulated below.
Loop Back Modes
LOOP-BACK[3:0]
RESULTING LOOP-BACK MODE
0000
Normal Mode (e.g., No Loop-back Mode)
0001
Remote Line Loop-back
In this mode, all data that is received by the Receive STS-1/STS-3 Serial Interface will
be routed to the Transmit STS-1/STS-3 Serial Interface.
0010
Local Transport Loop-back
In this mode, all data that is being output via the Transmit STS-1/STS-3 TOH Processor
block will also be routed to the Receive STS-1/STS-3 TOH Processor block.
0011
Local Path Loop-back
In this mode, all data that is output by the Transmit STS-1/STS-3 POH Processor block
(e.g., towards the Transmit STS-1/STS-3 TOH Processor block) will be routed to the
Receive STS-1/STS-3 POH Processor block.
0100 - 1111
Reserved - Do Not Use
TABLE 40: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0034)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
HRSYNC_Delay[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit STS-1/STS-3 Telecom Bus - Sync Delay - Upper Byte
The Transmit STS-1/STS-3 Telecom Bus can be configured to alignment its transmission of SONET/SDH frames with
8kHz pulses being applied to the TxSBFP_IN_OUT input pin.
The user is expected to apply a pulse (with the period of either a 6.48MHz or a 19.44MHz clock signal) at a rate of 8kHz
to the TxSBFP_IN_OUT input (pin number P5). The Transmit STS-1/STS-3 Telecom Bus will align its transmission of
the very first byte of a new STS-1/STS-3 frame, with a pulse at this input pin.
These READ/WRITE bit-fields (along with that within the STS-1/STS-3 Telecom Bus Control Register - Byte 2) are used
to specify the amount of delay (in terms of either 6.48MHz or 19.44MHz clock periods) that will exist between the rising
edge of TxSBFP_IN_OUT and the transmission of the very first byte, within a given STS-1/STS-3 frame via the Transmit
STS-1/STS-3 Telecom Bus.
` 0x0000 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to transmit the very first byte of a
new STS-1/STS-3 frame, upon detection of the rising edge of the TxSBFP_IN_OUT.
` 0x0001 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to delay its transmission of the very
first byte of a new STS-1/STS-3 frame, by one 6.48MHz or 19.44MHz clock period, and so on.
NOTE: This register is only active if the STS-1/STS-3 Telecom Bus Interface is enabled.
TABLE 41: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0035)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
HRSYNC_Delay[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
52
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT [7:0] - Transmit STS-1/STS-3 Telecom Bus - Sync Delay - Lower Byte
The Transmit STS-1/STS-3 Telecom Bus is aligned to the TxSBFP_IN_OUT input pin. The user is expected to apply
a pulse (with the period of either a 6.48MHz or a 19.44MHz clock signal) at a rate of 8kHz to the TxSBFP_IN_OUT input
(pin number P5). The Transmit STS-1/STS-3 Telecom Bus will align its transmission of the very first byte of a new STS1/STS-3 frame, with a pulse at this input pin.
These READ/WRITE bit-fields (along with that within the STS-1/STS-3 Telecom Bus Control Register - Byte 3) are used
to specify the amount of delay (in terms of either a 6.48MHz or a 19.44MHz clock periods) that will exist between the
rising edge of TxSBFP_IN_OUT and the transmission of the very first byte, within a given STS-1/STS-3 frame via the
Transmit STS-1/STS-3 Telecom Bus.
` 0x0000 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to transmit the very first byte of a
new STS-1/STS-3 frame, upon detection of the rising edge of the TxSBFP_IN_OUT. S
` 0x0001 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to delay its transmission of the very
first byte of a new STS-1/STS-3 frame, by one 6.48MHz or 19.44MHz clock period, and so on.
NOTE: This register is only active if the STS-1/STS-3 Telecom Bus Interface is enabled.
TABLE 42: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Set Telecom
Bus to STS1/STS-3
Mode
Fractional
Bandwidth
Enable
Slot_0
Master
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Slot[1:0]
BIT 2
Telecom Bus
Parity
Include V1
Signal
BIT 1
BIT 0
Framing
Telecom Bus
Pulse Enable - V1 Signal
Support
Enable
BIT 7 - Set Telecom Bus to STS-1/STS-3 Mode:
This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate at either the STS1/STS-3 or STS-3 rates.
` .0 - Configures the Telecom Bus Interface to operate at the STS-3/STS-1/STS-3 rate. In this case, the Telecom Bus
Interface will operate at a rate of 19.44MHz.
` 1 - Configures the Telecom Bus Interface to operate at the STS-1/STS-3 rate. In this case, the Telecom Bus Interface
will operate with a clock rate of 6.48MHz.
NOTE: This bit-field is only active if the XRT86SH328 has been configured to transmit/receive data (on the high-speed
side) via the Telecom Bus Interface.
BIT 6 - Fractional Bandwidth Enable:
If the XRT86SH328 is configured to transmit/receive data via the Telecom Bus Interface as STS-3/STS-1/STS-3 rates,
then this READ/WRITE bit-field can be used to configure the XRT86SH328 to operate in the Fractional Bandwidth
Mode.
If the XRT86SH328 is configured to operate in the Fractional Bandwidth Mode, then it will only fill in the STS-1/STS-3
time-slot data (within this outbound STS-3/STS-1 or STS-3 Data-stream) that pertains to this particular XRT86SH328.
The XRT86SH328 will tri-state the Transmit STS-1/STS-3 Telecom bus interface coincident to whenever the other STS1/STS-3 time-slot data would ordinarily be output via the STS-3/STS-1/STS-3 Telecom Bus Interface.
If the XRT86SH328 is NOT configured to operate in the Fractional Bandwidth Mode, then it will fill in the STS-1/STS-3
time-slot data (within this outbound STS-3/STS-1/STS-3 data-stream) that pertains to this particular XRT86SH328. The
XRT86SH328 will automatically set the bytes (within all of the remaining STS-1/STS-3 time-slots) to 0x00 as it outputs
this STS-3/STS-1/STS-3 data-stream via the Transmit STS-3/STS-1/STS-3 Telecom Bus Interface.
` 0 - Configures the XRT86SH328 to NOT operate in the Fractional Bandwidth Mode.
` 1 - Configures the XRT86SH328 to operate in the Fractional Bandwidth Mode.
NOTES:
1. If the user wishes to design in three (3) XRT86SH328s (into his/her system) such that they are sharing
the same STS-3/STS-1/STS-3 Telecom Bus, then the user must set this bit-field to 1.
53
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
2. This bit-field is only active if the Telecom Bus Interface has been configured to operate in the STS3/STS-1/STS-3 Mode.
BIT 5 - Slot Master Designate
This READ/WRITE bit-field is used to designate a given XRT86SH328 as being the Slot Master. If the user designates
a given XRT86SH328 has being the Slot Master, then this device will be responsible for sourcing the B1 byte, the REIL and RDI-L indicators (within the outbound STS-3/STS-1/STS-3 data-stream). Additionally, if a given XRT86SH328
has been designated as the Slot Master, then it will be responsible for generating an 8kHz signal via its
TxSBFP_IN_OUT input/output pin.
If a given XRT86SH328 is NOT configured to function as the Slot Master, then its TxSBFP_IN_OUT input/output pin will
function as an input pin
` 0 - Configures this particular XRT86SH328 to NOT be the Slot Master.
` 1 - Configures this particular XRT86SH328 to function as the Slot Master.
NOTES:
1. This bit-field is only value if (1) the Telecom Bus Interface is configured to operate in the STS-3/STS1/STS-3 Mode.
2.
The XRT86SH328 has been configured to operate in the Fractional Bandwidth Mode.
3.
This particular XRT86SH328 has been assigned the STS-1/STS-3 Time Slot of [0, 0].
BIT [4:3] STS-1/STS-3 Time Slot Assignment:
This READ/WRITE bit-field is used to specify which STS-1/STS-3 Time-slot that the XRT86SH328 will fill-in, if it has
been configured to operate in the Fractional Bandwidth Mode.
` Valid values to write into these bit-fields are: [0, 0], [0, 1], and [1, 0].
NOTES:
1. These bit-fields are only active if (1) the Telecom Bus Interface has been configured to operate in the
STS-3/STS-1/STS-3 Mode, and (2) if the user has configured the XRT86SH328 to operate in the Fractional
Bandwidth Mode.
2. If a given XRT86SH328 has been designed into a given STS-3/STS-1/STS-3 application (which involves
a total of three XRT86SH328s), for the XRT86SH328 (which has been designated as the Slot Master), the
user MUST set these bit-fields to [0, 0].
BIT2 - Telecom Bus Parity Include V1 Signal
BIT 1 - Telecom Bus Interface - Frame Pulse Mode:
This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse
Mode. If the STS-1/STS-3 Telecom Bus Interface is configured to operate in the Frame Pulse Mode, then all of the
following will be true.
•
The TxA_C1J1V1_FP output pin will only pulse high coincident to whenever the XRT86SH328 outputs the
very first byte of a given STS-1/STS-3 frame via the Transmit STS-1/STS-3 Telecom Bus Interface - Output
Data Bus (TxA_D[7:0]).
•
The RxD_C1J1V1_FP input pin will accept a pulse, coincident to whenever the very first byte of the incoming
STS-1/STS-3 frame is being placed on the Receive STS-1/STS-3 Telecom Bus Interface - Input Data Bus
(RxD_D[7:0]).
If the STS-1/STS-3 Telecom Bus Interface is NOT configured to operate in the Frame Pulse Mode, then the Telecom
Bus Interface will perform as configured in Bits 0 (Telecom Bus - V1 Signal Support Enable) within this register, and Bit
3 (Telecom Bus J1 Only) within the STS-3/STS-1/STS-3 Telecom Bus Control Register - Byte 0.0 - Configures the STS1/STS-3 Telecom Bus Interface to NOT operate in the Frame Pulse Mode.1 - Configures the STS-1/STS-3 Telecom
Bus Interface to operate in the Frame Pulse Mode.
BIT - 0 - Transmit STS-1/STS-3 Telecom Bus - V1 Pulse Enable:
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 Telecom Bus Interface to pulse the
TxA_C1J1V1_FP output pin HIGH coincident to whenever the XRT86SH328 outputs a V1 byte via the Transmit STS1/STS-3 Telecom Bus Interface - Output Data Bus (TxA_D[7:0]).
` 0 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to NOT denote the V1 byte via the TxA_C1J1V1_FP
output pin.
` 1 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to denote the V1 byte via the TxA_C1J1V1_FP
output pin.
54
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
REV. P1.0.6
NOTE:
XRT86SH328
This register bit is only active if the XRT86SH328 has been configured to VT/TU map T1/E1 data into
SONET/SDH.
TABLE 43: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036)
BIT7
BIT6
BIT 5
BIT 4
Set Telecom
Bus to
STS-1/STS3 Mode
Fractional
Bandwidth
Enable
Slot_0
Master
R/W
R/W
R/W
R/W
0
0
0
0
BIT 3
BIT 2
BIT 1
BIT 0
Telecom Bus
Parity
Include
V1 Signal
Framing
Pulse
Enable
Telecom
Bus - V1
Signa
Support
Enable
R/W
R/W
R/W
R/W
0
0
0
0
Slot[1:0]
BIT 7 - Set Telecom Bus to STS-1/STS-3 Mode
This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate at either the STS1/STS-3 or STS-3 rates.
` 0 - Configures the Telecom Bus Interface to operate at the STS-3/STS-3 rate.
In this case, the Telecom Bus Interface will operate at a rate of 19.44MHz.
` 1 - Configures the Telecom Bus Interface to operate at the STS-1/STS-3 rate. In this case, the Telecom Bus Interface
will operate with a clock rate of 6.48MHz.
NOTE: This bit-field is only active if the XRT86SH328 has been configured to transmit/receive data (on the high-speed
side) via the Telecom Bus Interface.
BIT 6 - Fractional Bandwidth Enable
If the XRT86SH328 is configured to transmit/receive data via the Telecom Bus Interface as STS-3/STS-1/STS-3 rates,
then this READ/WRITE bit-field is used to configure the XRT86SH328 to operate in the Fractional Bandwidth Mode.
If the user configures the XRT86SH328 to operate in the Fractional Bandwidth Mode, then it will only fill in the STS1/STS-3 time-slot data (within this outbound STS-3/STS-1/STS-3 data-stream) that pertains to this particular
XRT86SH328. The XRT86SH328 will tri-state the Transmit STS-1/STS-3 Telecom bus interface coincident to
whenever the other STS-1/STS-3 time-slot data would ordinarily be output via the STS-3/STS-1/STS-3 Telecom Bus
Interface.
If the user configures the XRT86SH328 to NOT operate in the Fractional Bandwidth Mode, then it will fill in the STS1/STS-3 time-slot data (within this outbound STS-3/STS-1/STS-3 data-stream) that pertains to this particular
XRT86SH328. The XRT86SH328 will automatically set the bytes (within all of the remaining STS-1/STS-3 time-slots)
to 0x00 as it outputs this STS-3/STS-1/STS-3 data-stream via the Transmit STS-3/STS-1/STS-3 Telecom Bus Interface.
` 0 - Configures the XRT86SH328 to NOT operate in the Fractional Bandwidth Mode.
` 1 - Configures the XRT86SH328 to operate in the Fractional Bandwidth Mode.
NOTES:
1. To design in three (3) XRT86SH328s (into the users system) such that they are sharing the same STS3/STS-1/STS-3 Telecom Bus, then the user must set this bit-field to 1.
2. This bit-field is only active if the Telecom Bus Interface has been configured to operate in the STS3/STS-1/STS-3 Mode.
BIT 5 - Slot 0 Master Designate
This READ/WRITE bit-field is used to designate a given XRT86SH328 as being the Slot Master. If the user designates
a given XRT86SH328 has being the Slot Master, then this device will be responsible for sourcing the B1 byte, the REIL and RDI-L indicators (within the outbound STS-3/STS-1/STS-3 data-stream). Additionally, if a given XRT86SH328
has been designated as the Slot Master, then it will be responsible for generating an 8kHz signal via its
TxSBFP_IN_OUT input/output pin.
If a given XRT86SH328 is NOT configured to function as the Slot Master, then its TxSBFP_IN_OUT input/output pin
will function as an input pin.
` 0 - Configures this particular XRT86SH328 to NOT be the Slot Master.
55
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 1 - Configures this particular XRT86SH328 to function as the Slot Master.
NOTES:
1. This bit-field is only value if (1) the Telecom Bus Interface is configured to operate in the STS-3/STS1/STS-3 Mode.
2.
The XRT86SH328 has been configured to operate in the Fractional Bandwidth Mode.
3.
This particular XRT86SH328 has been assigned the STS-1/STS-3 Time Slot of [0, 0].
BIT [4:3] - STS-1/STS-3 Time Slot Assignmen
This READ/WRITE bit-field is used to specify which STS-1/STS-3 Time-slot that the XRT86SH328 will fill-in, if it has
been configured to operate in the Fractional Bandwidth Mode.
Valid values to write into these bit-fields are: [0, 0], [0, 1], and [1, 0].
NOTES:
1. These bit-fields are only active if (1) the Telecom Bus Interface has been configured to operate in the
STS-3/STS-1/STS-3 Mode, and (2) if the user has configured the XRT86SH328 to operate in the Fractional
Bandwidth Mode.2.
2. If a given XRT86SH328 has been designed into a given STS-3/STS-1/STS-3 application (which involves
a total of three XRT86SH328s), for the XRT86SH328 (which has been designated as the Slot Master), the
user MUST set these bit-fields to [0, 0].
BIT 2 - Telecom Bus Parity Include V1 Signal
BIT 1 - .Telecom Bus Interface - Frame Pulse Mode
This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse
Mode. If the user configures the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode, then all of
the following will be true.
•
The TxA_C1J1V1_FP output pin will only pulse high coincident to whenever the XRT86SH328 outputs the
very first byte of a given STS-1/STS-3 frame via the Transmit STS-1/STS-3 Telecom Bus Interface - Output
Data Bus (TxA_D[7:0])
•
The RxD_C1J1V1_FP input pin will accept a pulse, coincident to whenever the very first byte of the incoming
STS-1/STS-3 frame is being placed on the Receive STS-1/STS-3 Telecom Bus Interface - Input Data Bus
(RxD_D[7:0]).
If the user does NOT configure the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode, then the
Telecom Bus Interface will perform as configured in Bits 0 (Telecom Bus - V1 Signal Support Enable) within this register,
and BIT 3 (Telecom Bus J1 Only) within the STS-3/STS-1/STS-3 Telecom Bus Control Register - Byte 0.
` 0 - Configures the STS-1/STS-3 Telecom Bus Interface to NOT operate in the Frame Pulse Mode
` 1 - Configures the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode
BIT 0 - Transmit STS-1/STS-3 Telecom Bus - V1 Pulse Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 Telecom Bus Interface to pulse the
TxA_C1J1V1_FP output pin HIGH coincident to whenever the XRT86SH328 outputs a V1 byte via the Transmit STS1/STS-3 Telecom Bus Interface - Output Data Bus (TxA_D[7:0])
` .0 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to NOT denote the V1 byte via the
TxA_C1J1V1_FP output pin.
` 1 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to denote the V1 byte via the TxA_C1J1V1_FP
output pin.
NOTE:
This register bit is only active if the XRT86SH328 has been configured to VT/TU map T1/E1 data into
SONET/SDH.
56
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 44: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0037)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Telecom Bus
ON
Telecom Bus
Disable
Unused
Telecom Bus
Parity Type
Telecom Bus
J1 Only
Telecom Bus
Parity Odd
Telecom Bus
Parity
Enable
Rephase
STS-1
R/W
R/W
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
1
BIT 7 - Telecom Bus Enable
This READ/WRITE is used to either enable or disable the 51.84/155.52Mbps Telecom Bus Interface.
` 0 - Telecom Bus Interface is Disabled:STS-1/STS-3 data will output via the STS-1/STS-3 Serial Interface.
` 1 - Telecom Bus Interface is Enabled:In this selection, both the Transmit and Receive STS-1/STS-3 Telecom Bus
Interfaces will be enabled.
BIT 6 - Telecom Bus Tri-state
This READ/WRITE bit-field is used to tri-state the Telecom Bus Interface.
` 0 - Telecom Bus Interface is NOT tri-stated.
` 1 - Telecom Bus Interface is tri-stated.
NOTE: This READ/WRITE bit-field is ignored if the STS-1/STS- 3 Transmit and Receive STS-1/STS-3 Telecom Bus
Interfaces are disabled.
BIT 5 - Unused
BIT 4- Telecom Bus Parity Type
This READ/WRITE bit-field is used to define the parameters, over which Telecom Bus parity will be computed.
` 0 - Parity is computed/verified over the Transmit STS-1/STS-3 and Receive Telecom Bus - data bus pins (e.g.,
TXA_D[7:0] and RXD_D[7:0]).If the user implements this selection, then the following will happen.
a.
The Transmit STS-1/STS-3 Telecom Bus Interface will compute and output parity (via the TXA_DP output pin)
based upon and coincident with the data being output via the TXA_D[7:0] output pins.
b.
The STS-1/STS-3 Receive Telecom Bus Interface will compute and verify the parity data (which is input via
the RXD_DP input pin) based upon the data which is being input (and latched) via the RXD_D[7:0] input pins.
` 1 - Parity is computed/verified over the Transmit STS-1/STS-3 and Receive Telecom Bus - data bus pins (e.g.,
TXA_D[7:0] and RXD_D[7:0]), the C1J1 and PL input/output pins.
` If the user implements this selection, then the following will happen.
a.
The Transmit STS-1/STS-3 Telecom Bus Interface will compute and output parity (via the TXA_DP output)
based upon and coincident with (1) the data being output via the TXA_D[7:0] output pins, (2) the state of the
TXA_PL output pin, and (3) the state of the TXA_C1J1 output pin.
b.
The Receive STS-1/STS-3 Telecom Bus Interface will compute and verify the parity data (which is input via
the RXD_DP input pin) based upon (1) the data which is being input (and latched) via the RXD_D[7:0] input
pins, (2) the state of the RXD_PL input pin, and (3) the state of the RXD_C1J1 input pin.
NOTES:
1.
This bit-field is disabled if the STS-1/STS-3 Telecom Bus is disabled.
2. The user can configure the STS-1/STS-3 Telecom Bus to compute with either even or odd parity, by
writing the appropriate data into BIT 2 (Telecom Bus Parity - Odd), within this register.
BIT 3 - Telecom Bus - J1 Indicator Only:
This READ/WRITE bit-field is used to configure how the Transmit STS-1/STS-3 and Receive Telecom Bus interface
handles the TXA_C1J1 and RXD_C1J1 signals, as described below.
` 0 - C1 and J1 Bytes
This selection configures the following.
a.
The Transmit STS-1/STS-3 Telecom Bus to pulse the TXA_C1J1V1_FP output coincident to whenever the
C1 and J1 bytes are being output via the TXA_D[7:0] output pins.
57
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
b.
The STS-1/STS-3 Receive Telecom Bus will expect the RXD_C1J1V1_FP input to pulse high coincident to
whenever the C1 and J1 bytes are being sampled via the RXD_D[7:0] input pins.
` 1 - J1 Bytes Only
This selection configures the following.
a.
The Transmit STS-1/STS-3 Telecom Bus Interface to only pulse the TXA_C1J1V1_FP output pin coincident
to whenever the J1 byte is being output via the TXA_D[7:0] output pins.
NOTE: The TXA_C1J1V1_FP output pin will NOT be pulsed high whenever the C1 byte is being output via the
TXA_D[7:0] output pins.
b.
NOTE:
The STS-1/STS-3 Receive Telecom Bus Interface will expect the RXD_C1J1V1_FP input to only pulse high
coincident to whenever the J1 byte is being sampled via the RXD_D[7:0] input pins.
The RXD_C1J1V1_FP input pin will NOT be pulsed high whenever the C1 byte is being input via the
RXD_D[7:0] input pins
BIT 2 - Telecom Bus Parity - ODD Parity Select:
This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to do the following.
a.
In the Transmit (Drop) DirectionThe STS-1/STS-3 Telecom Bus to compute either the EVEN or ODD parity
over the contents of the (1) TxD_D[7:0] output pins, or (2) TxD_D[7:0] output pins, the states of the TxD_PL
and TxD_C1J1 output pins (depending upon user setting for BIT 3).
b.
In the Receive (Add) DirectionReceive STS-1/STS-3 Telecom Bus to compute and verify the EVEN or ODD
parity over the contents of the (1) RxA_D[7:0] input pins, or (2) RxA_D[7:0] input pins, the states of the
RxA_PL and RxA_C1J1 input pins (depending upon user setting for BIT 3).
` 0 - Configures Transmit (Drop) Telecom Bus to compute EVEN parity and configures the Receive (Add) Telecom Bus
to verify EVEN parity.
` 1 - Configures Transmit (Drop) Telecom Bus to compute ODD parity and configures the Receive (Add) Telecom Bus
to verify ODD parity.
BIT 1 - Telecom Bus Parity Enable
This READ/WRITE bit-field is used to either enable or disable parity calculation and placement via the TxA_DP output
pin. This bit field also is used to enable or disable parity verification by the Receive Telecom Bus.
` 0 - Disables Parity Calculation (on the Transmit Telecom Bus) and Disables Parity Verification (on the Receive
Telecom Bus.
` 1 - Enables Parity Calculation and Verification
BIT 0 - Telecom Bus - Rephase Enable
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 Telecom Bus to operate in either the
Rephase ON or Rephase OFF Modes.
If the user configures the Receive STS-1/STS-3 Telecom Bus Interface to operate on the Rephase ON Mode, then the
Receive STS-1/STS-3/STS-1/STS-3 TOH/POH Processor blocks will internally compute the Pointer Bytes, based upon
the data that it receives via the RxD_D[7:0] input pins.
If the user configures the Receive STS-1/STS-3 Telecom Bus Interface to operate in the Rephase OFF Mode, then the
Receive STS-1/STS-3/STS-1/STS-3 TOH/POH Processor blocks will NOT internally compute the Pointer Bytes, based
upon the data that it receives via the RxD_D[7:0] input pins. In this case, the Voyager device will rely upon the signaling
via the Telecom Bus Interface pins (e.g., via the RxD_PL and RxD_C1J1V1_FP pins) in order to compute these pointer
bytes.
NOTE: If the Receive STS-1/STS-3 Telecom Bus is being provided with pulses denoting the C1 and J1 bytes (via the
RxD_C1J1V1_FP input pin), then this feature is unnecessary.
` 0 - Configures the Telecom Bus Interface to operate in the Rephase OFF Mode.
` 1 - Configures the Telecom Bus Interface to operate in the Rephase ON Mode.
58
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 45: OPERATION BLOCK - INTERFACE CONTROL REGISTER (ADDRESS = 0X003C)
BIT7
BIT6
BIT 5
Unused
BIT 4
BIT 3
Telecom Bus
Parity Error
Interrupt
Status
BIT 2
BIT 1
Unused
BIT 0
Telecom Bus
Parity Error
Interrupt
Enable
R/O
R/O
R/O
RUR
R/O
R/O
R/O
R/W
0
0
0
0
0
0
0
0
BIT [7:5] - Unused
BIT 4- Telecom Bus Interface - Detection of Parity Error Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Receive STS-1/STS-3 Telecom Bus Interface has
detected a parity error within the incoming STS-1/STS-3 data-stream since the last read of this register, as described
below.
` 0 - Indicates that the Receive STS-1/STS-3 Telecom Bus Interface has NOT detected a parity error since the last read
of this register.
` 1 - Indicates that the Receive STS-1/STS-3 Telecom Bus Interface has detected a parity error (and has generated
the Detection of Parity Error interrupt) since the last read of this register.
NOTE: This register bit-field is only active if the XRT86SH328 has been configured to exchange STS-1/STS-3 data via
the Telecom Bus Interface.
BIT [3:1] - Unused
BIT 0 - Telecom Bus Interface - Detection of Parity Error Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Receive STS-1/STS-3 Telecom Bus Interface Detection of Parity Error interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 Telecom Bus Interface will
generate this interrupt anytime it detects a parity error within the incoming STS-1/STS-3 data-stream.
` 0 - Disables the Receive STS-1/STS-3 Telecom Bus Interface - Detection of Parity Error interrupt.
` 1 - Enables the Receive STS-1/STS-3 Telecom Bus Interface - Detection of Parity Error interrupt.
TABLE 46: OPERATION GENERAL PURPOSE INPUT/OUTPUT REGISTER - BYTE 0 (ADDRESS = 0X0047)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
GPIO_7
GPIO_6
GPIO_5
GPIO_4
GPIO_3
GPIO_2
GPIO_1
GPIO_0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits [7:0] - General Purpose Input/Output Pin # 7 thru 0
The function of this READ/WRITE bit-field depends upon whether the GPIO_[7:0] pins are configured to be an input or
an output pin.
If GPIO_[7:0] is configured to be an input pin:
These register bits operates as a READ-ONLY bit-fields that reflects the state of the GPIO_[7:0] input pins.
If the GPIO_[7:0] input pins are pulled to a logic HIGH, then this register bit will be set to 1. Conversely, if the GPIO_7
input pin is pulled to a logic LOW, then this register bit will be set to 0.
If GPIO_[7:0] is configured to be an output pin
Tthe user can control the logic level of GPIO_[7:0] by writing the appropriate value into these bit-fields.
` 0 - Causes the GPIO_[7:0] output pins to be driven LOW.
` 1 - Causes the GPIO_[7:0] output pins to be driven HIGH.
59
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 47: OPERATION GENERAL PURPOSE INPUT/OUTPUT DIRECTION REGISTER 0 (ADDRESS = 0X004B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
GPIO_DIR[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - GPIO_[7:0] Direction Select
These READ/WRITE bit-fields are used to configure the GPIO_[7:0] pins to function as either input or output pins.
` 0 - Configures GPIO_[7:0] to function as input pins.
` 1 - Configures GPIO_[7:0] to function as output pins.
TABLE 48: OPERATION I/O CONTROL REGISTER (ADDRESS = 0X004F)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
RxCLK_Select[4:0]
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:5] - Unused
BIT [4:0] - Recovered T1/E1 Clock Select[4:0]
These READ/WRITE bit-fields are used to select any one of 28 T1 or 21 E1 Recovered Clock signals, and do either of
the following.· Output a replica of this selected clock signal via the RCLKOUT output pins.· Synthesize a 19.44MHz
clock signal (from this selected Recovered T1/E1 Clock) and output this signal via the RCLKOUT output pin.
The relationship between the contents within these bit-fields and the selected channel is tabulated below.
Bit Field Contents
RXCLK_SELECT[4:0]
SELECTED
CHANNEL
00000
NONE
00001
Channel 0
00010
Channel 1
00011
Channel 2
00100
Channel 3
00101
Channel 4
00110
Channel 5
00111
Channel 6
01000
Channel 7
01001
Channel 8
01010
Channel 9
01011
Channel 10
COMMENT
RCLKOUT pin is tri-stated
60
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Bit Field Contents
RXCLK_SELECT[4:0]
SELECTED
CHANNEL
01100
Channel 11
01101
Channel 12
01110
Channel 13
01111
Channel 14
10000
Channel 15
10001
Channel 16
10010
Channel 17
10011
Channel 18
10100
Channel 19
10101
Channel 20
10110
Channel 21
10111
Channel 22
11000
Channel 23
11001
Channel 24
11010
Channel 25
11011
Channel 26
11100
Channel 27
11101
NONE
RCLKOUT is an Input pin
11110
NONE
RCLKOUT is an Input Pin
11111
NONE
RCLKOUT is an Input Pin
COMMENT
TABLE 49: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS =
0X0050)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
VT-Side
Channel 27
DS1/E1
Framer
VT-Side
Channel 26
DS1/E1
Framer
VT-Side
Channel 25
DS1/E1
Framer
VT-Side
Channel 24
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:4]- Unused
BIT [3:0] - DS1/E1 Framer Block (VT Side) Channels 27, 26, 25 & 24
These READ-ONLY bit-fields indicate whether or not the DS1/E1 Framer block (on the VT Side) associated with
Channel [27:24] have a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer block sassociated with Channel [27:24] (on the VT Side) does NOT have a
61
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
pending interrupt request.
` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [27:24] (on the VT side) DOES have a pending
interrupt request.
TABLE 50: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS =
0X0051)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
VT-Side
Channel 23
DS1/E1
Framer
VT-Side
Channel 22
DS1/E1
Framer
VT-Side
Channel 21
DS1/E1
Framer VTSide Channel 20
DS1/E1
Framer
VT-Side
Channel 19
DS1/E1
Framer
VT-Side
Channel 18
DS1/E1
Framer
VT-Side
Channel 17
DS1/E1
Framer
VT-Side
Channel 16
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - DS1/E1 Framer Block (VT Side) Channels [23:16]
These READ-ONLY bit-field indicates whether or not the DS1/E1 Framer block (on the VT Side) associated with
Channel [23:16] have a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer blocks associated with Channel [23:16] (on the VT Side) does NOT have a
pending interrupt request.
` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [23:16] (on the VT side) DOES have a pending
interrupt request.
TABLE 51: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS =
0X0052)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
VT-Side
Channel 15
DS1/E1
Framer
VT-Side
Channel 14
DS1/E1
Framer
VT-Side
Channel 13
DS1/E1
Framer
VT-Side
Channel 12
DS1/E1
Framer
VT-Side
Channel 11
DS1/E1
Framer
VT-Side
Channel 10
DS1/E1
Framer
VT-Side
Channel 9
DS1/E1
Framer
VT-Side
Channel 8
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - DS1/E1 Framer Block (VT Side) Channels [15:8]
These READ-ONLY bit-field indicates whether or not the DS1/E1 Framer block (on the VT Side) associated with
Channel [15:8] have a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer blocks associated with Channel [15:8] (on the VT Side) does NOT have a
pending interrupt request.
` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [15:8] (on the VT side) DOES have a pending
interrupt request.
62
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 52: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS =
0X0053)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
VT-Side
Channel 7
DS1/E1
Framer
VT-Side
Channel 6
DS1/E1
Framer
VT-Side
Channel 5
DS1/E1
Framer
VT-Side
Channel 4
DS1/E1
Framer
VT-Side
Channel 3
DS1/E1
Framer
VT-Side
Channel 2
DS1/E1
Framer
VT-Side
Channel 1
DS1/E1
Framer
VT-Side
Channel 0
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - DS1/E1 Framer Block (VT Side) Channels [7:0]
These READ-ONLY bit-field indicates whether or not the DS1/E1 Framer block (on the VT Side) associated with
Channel [7:0] has a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer blocks associated with Channel [7:0] (on the VT Side) does NOT have a pending
interrupt request.
` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [7:0] (on the VT side) DOES have a pending
interrupt request.
TABLE 53: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS
= 0X0054)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
M13-Side
Channel 27
DS1/E1
Framer
M13-Side
Channel 26
DS1/E1
Framer
M13-Side
Channel 25
DS1/E1
Framer
M13-Side
Channel 24
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - BIT 4 - Unused
BIT [3:0] - DS1/E1 Framer Block (M13 Side) Channels [27:24]
These READ-ONLY bit-field indicate whether or not the DS1/E1 Framer block (on the M13 Side) associated with
Channel [27:24] have a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer block associated with Channel [27:24] (on the M13 Side) does NOT have a
pending interrupt request.
` 1 - Indicates that the DS1/E1 Framer block associated with Channel [27:24] (on the M13 side) DOES have a pending
interrupt request.
TABLE 54: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS
= 0X0055)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
M13-Side
Channel 23
DS1/E1
Framer
M13-Side
Channel 22
DS1/E1
Framer
M13-Side
Channel 21
DS1/E1
Framer
M13-Side
Channel 20
DS1/E1
Framer
M13-Side
Channel 19
DS1/E1
Framer
M13-Side
Channel 18
DS1/E1
Framer
M13-Side
Channel 17
DS1/E1
Framer
M13-Side
Channel 16
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
63
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT [7:0] - DS1/E1 Framer Block (M13 Side) Channel [23:16]
These READ-ONLY bit-fields indicates whether or not the DS1/E1 Framer block (on the M13 Side) associated with
Channel [23:16] has a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer block associated with Channel [23:16] (on the M13 Side) does NOT have a
pending interrupt request.
` 1 - Indicates that the DS1/E1 Framer block associated with Channel [23:16] (on the M13 side) DOES have a pending
interrupt request.
TABLE 55: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS
= 0X0056)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
Framer
M13-Side
Channel 15
DS1/E1
Framer
M13-Side
Channel 14
DS1/E1
Framer
M13-Side
Channel 13
DS1/E1
Framer
M13-Side
Channel 12
DS1/E1
Framer
M13-Side
Channel 11
DS1/E1
Framer
M13-Side
Channel 10
DS1/E1
Framer
M13-Side
Channel 9
DS1/E1
Framer
M13-Side
Channel 8
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - DS1/E1 Framer Block (M13 Side) Channels [15:8]
These READ-ONLY bit-fields indicate whether or not the DS1/E1 Framer block (on the M13 Side) associated with
Channels [15:8] have a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer block associated with Channel [15:8] (on the M13 Side) does NOT have a
pending interrupt request.
` 1 - Indicates that the DS1/E1 Framer block associated with Channel [15:8] (on the M13 side) DOES have a pending
interrupt request.
TABLE 56: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS
= 0X0057)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1
DS1/E1
DS1/E1
DS1/E1
DS1/E1
DS1/E1
DS1/E1
DS1/E1
Framer M13- Framer M13- Framer M13- Framer M13- Framer M13- Framer M13- Framer M13- Framer M13Side ChanSide ChanSide ChanSide ChanSide ChanSide ChanSide ChanSide Channel 7
nel 6
nel 5
nel 4
nel 3
nel 2
nel 1
nel 0
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - DS1/E1 Framer Block (M13 Side) Channels [7:0]
These READ-ONLY bit-fields indicate whether or not the DS1/E1 Framer block (on the M13 Side) associated with
Channels [7:0] have a pending Interrupt Request.
` 0 - Indicates that the DS1/E1 Framer block associated with Channel [7:0] (on the M13 Side) does NOT have a pending
interrupt request.
` 1 - Indicates that the DS1/E1 Framer block associated with Channel [7:0] (on the M13 side) DOES have a pending
interrupt request.
64
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 57: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0058)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1 LIU
Channel 27
DS1/E1 LIU
Channel 26
DS1/E1 LIU
Channel 25
DS1/E1 LIU
Channel 24
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT [3:0] - DS1/E1 LIU Block Channels [27:24]
These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [27:24] have a
pending Interrupt Request.
` 0 - Indicates that the DS1/E1 LIU block associated with Channel [27:24] does NOT have a pending interrupt request.
` 1 - Indicates that the DS1/E1 LIU block associated with Channel [27:24] DOES have a pending interrupt request.
TABLE 58: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0059)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1 LIU
Channel 23
DS1/E1 LIU
Channel 22
DS1/E1 LIU
Channel 21
DS1/E1 LIU
Channel 20
DS1/E1 LIU
Channel 19
DS1/E1 LIU
Channel 18
DS1/E1 LIU
Channel 17
DS1/E1 LIU
Channel 16
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Bit[ 7:0] - DS1/E1 LIU Block Channels [23:16]
These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [23:16] have a
pending Interrupt Request.
` 0 - Indicates that the DS1/E1 LIU block associated with Channel [23:16] does NOT have a pending interrupt request.
` 1 - Indicates that the DS1/E1 LIU block associated with Channel [23:16] DOES have a pending interrupt request.
TABLE 59: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005A)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1 LIU
Channel 15
DS1/E1 LIU
Channel 14
DS1/E1 LIU
Channel 13
DS1/E1 LIU
Channel 12
DS1/E1 LIU
Channel 11
DS1/E1 LIU
Channel 10
DS1/E1 LIU
Channel 9
DS1/E1 LIU
Channel 8
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Bit [7:0] - DS1/E1 LIU Block Channel [15:8]
These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [15:8] have a
pending Interrupt Request.
` 0 - Indicates that the DS1/E1 LIU block associated with Channel [15:8] does NOT have a pending interrupt request.
` 1 - Indicates that the DS1/E1 LIU block associated with Channel [15:8] DOES have a pending interrupt request.
65
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 60: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS1/E1 LIU
Channel 7
DS1/E1 LIU
Channel 6
DS1/E1 LIU
Channel 5
DS1/E1 LIU
Channel 4
DS1/E1 LIU
Channel 3
DS1/E1 LIU
Channel 2
DS1/E1 LIU
Channel 1
DS1/E1 LIU
Channel 0
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - DS1/E1 LIU Block Channels [7:0]
These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [7:0] have a
pending Interrupt Request.
` 0 - Indicates that the DS1/E1 LIU block associated with Channel [7:0] does NOT have a pending interrupt request.
` 1 - Indicates that the DS1/E1 LIU block associated with Channel [7:0] DOES have a pending interrupt request.
TABLE 61: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005C)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
VT Mapper
Block
Channel 27
VT Mapper
Block
Channel 26
VT Mapper
Block
Channel 25
VT Mapper
Block
Channel 24
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
Bit [3:0] - VT-Mapper Block Channels [27:24]
These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [27:24] have a
pending Interrupt Request.
` 0 - Indicates that the VT-Mapper block associated with Channel [27:24] does NOT have a pending interrupt request.
` 1 - Indicates that the VT-Mapper block associated with Channel [27:24] DOES have a pending interrupt request.
TABLE 62: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005D)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
VT-Mapper
Channel 23
VT-Mapper
Channel 22
VT-Mapper
Channel 21
VT-Mapper
Channel 20
VT-Mapper
Channel 19
VT-Mapper
Channel 18
VT-Mapper
Channel 17
VT-Mapper
Channel 16
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - VT-Mapper Block Channels [23:16]
These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [23:16] have a
pending Interrupt Request.
` 0 - Indicates that the VT-Mapper block associated with Channel [23:16] does NOT have a pending interrupt request.
` 1 - Indicates that the VT-Mapper block associated with Channel [23:16] DOES have a pending interrupt request.
66
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 63: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005E)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
VT-Mapper
Channel 15
VT-Mapper
Channel 14
VT-Mapper
Channel 13
VT-Mapper
Channel 12
VT-Mapper
Channel 11
VT-Mapper
Channel 10
VT-Mapper
Channel 9
VT-Mapper
Channel 8
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - VT-Mapper Block Channels [15:8]
These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [15:8] have a
pending Interrupt Request.
` 0 - Indicates that the VT-Mapper block associated with Channel [15:8] does NOT have a pending interrupt request.
` 1 - Indicates that the VT-Mapper block associated with Channel [15:8] DOES have a pending interrupt request.
TABLE 64: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005F)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
VT-Mapper
Channel 7
VT-Mapper
Channel 6
VT-Mapper
Channel 5
VT-Mapper
Channel 4
VT-Mapper
Channel 3
VT-Mapper
Channel 2
VT-Mapper
Channel 1
VT-Mapper
Channel 0
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Bit[ 7:0] - VT-Mapper Block Channels [7:0]
These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [7:0] have a
pending Interrupt Request.
` 0 - Indicates that the VT-Mapper block associated with Channel [7:0] does NOT have a pending interrupt request.
` 1 - Indicates that the VT-Mapper block associated with Channel [7:0] DOES have a pending interrupt request.
2.2
LIU COMMON CONTROL REGISTERS
TABLE 65: LIU COMMON CONTROL REGISTER 0 (ADDRESS = 0X0100)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Reserved
ATAOS
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
BIT 2
BIT 1
BIT 0
TCLKCNTL
LIU Software RESET
R/W
R/W
R/W
0
0
0
Reserved
BIT 7 - Reserved:
BIT 6 - ATAOS: Automatic Transmit All Ones Upon RLOS Condition
If ATAOS is selected, an all ones pattern will be transmitted on any channel that experiences an RLOS condition. If an
RLOS condition does not occur, TAOS will remain inactive.
0 = Disabled
1 = Enabled
Bits [5:2] - Reserved:
BIT 1 - TCLKCNTL
If TCLKCNTL is selected, and if the transmit clock to the DS-1 framer is missing, Low, or High, then the transmitter
outputs to the line interface will send an All Ones Signal.
0 = Disabled
67
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
1 = Enabled
BIT 0 - LIU Software RESET:
Writing a 1 to this bit for more than 10µS initiates a device reset for all internal circuits except the microprocessor register
bits. To reset the registers to their default setting, use the Hardware Reset pin (See the pin description for more details)
0 = Disabled
1 = Enabled
TABLE 66: LIU COMMON CONTROL REGISTER 1 (ADDRESS = 0X0101)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LCVB_OF
PLL19_Dis
Reserved
Slicer Level
Select[1:0]
RXMUTE
EXLOS
ICT
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Line Code Violation / Counter Overflow Monitor Select
This bit is used to select the monitoring activity between the LCV and the counter overflow status. When the 16-bit LCV
counter saturates, the counter overflow condition is activated. By default, the LCV activity is monitored by bit D4 in
register 0xN005, where N is equal to the channel number.
` 0 - Monitoring LCV
` 1 - Monitoring the counter overflow status
BIT 6 - PLL 19.44MHz Disable
This bit is used in conjunction with the DS-1/E1 recovered clock to synchronize to a 19.44MHz clock source. If this bit
is set High, one of the 28 channel recovered line clocks, or an external line clock and be used to provide this
synchronization.
` 0 - Disabled
` 1 - Enabled
BIT 5 - Reserved
BIT [4:3] - Slicer Level Select
These bits are to used to select the amplitude level that is used by the receive line interface to determine whether the
input data is High or Low.
00 - 50%
01 - 45%
10 - 55%
11 - 68%
BIT 2 - RxMUTE
This bit is used to force the receive DS-1/E1 signals Low to prevent chattering any time that the DS-1/E1 receiver inputs
at Rtip/Rring experience an RLOS condition.
` 0 - Disabled
` 1 - Enabled
BIT 1 - EXLOS
The number of zeros required to declare a Digital Loss of Signal is extended to 4,096.
` 0 - Normal RLOS operation
` 1 - EXLOS enabled
BIT 0 - In Circuit Testing
For Internal use only. This bit should be set to Low.
68
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 67: LIU COMMON CONTROL REGISTER 2 (ADDRESS = 0X0102)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
CLKSEL[3:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Reserved
BIT [3:0] - Input Clock Selection
These bits are used to select the frequency of the input clock source to the PLL. Any state not listed is reserved.
0000 = 2.048 MHz
0001 = 1.544 MHz
1000 = 4.096 MHz
1001 = 3.088 MHz
1010 = 8.192 MHz
1011 = 6.176 MHz
1100 = 16.384 MHz
1101 = 12.352 MHz
1110 = 2.048 MHz
1111 = 1.544 MHz
TABLE 68: LIU COMMON CONTROL REGISTER 3 (ADDRESS = 0X0103)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DS1/E1 LIU
Global
Interrupt
Status
Channel 6
DS1/E1 LIU
Global
Interrupt
Status
Channel 5
DS1/E1 LIU
Global
Interrupt
Status
Channel 4
DS1/E1 LIU
Global
Interrupt
Status
Channel 3
DS1/E1 LIU
Global
Interrupt
Status
Channel 2
DS1/E1 LIU
Global
Interrupt
Status
Channel 1
DS1/E1 LIU
Global
Interrupt
Status
Channel 0
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - Reserved
BIT [6:0] - Global Channel Interrupt Status - Channels 0 to 6
These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If
a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register
is read back, these bit fields will automatically return Low.
69
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 69: LIU COMMON CONTROL REGISTER 4 (ADDRESS = 0X0104)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DS1/E1 LIU
Global
nterrupt
Status
Channel 13
DS1/E1 LIU
Global
nterrupt
Status
Channel 12
DS1/E1 LIU
Global
nterrupt
Status
Channel 11
DS1/E1 LIU
Global
nterrupt
Status
Channel 10
DS1/E1 LIU
Global
nterrupt
Status
Channel 9
DS1/E1 LIU
Global
nterrupt
Status
Channel 8
DS1/E1 LIU
Global
nterrupt
Status
Channel 7
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - Reserved
BIT [6:0] - Global Channel Interrupt Status - Channels 7 to 13
These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If
a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register
is read back, these bit fields will automatically return Low.
TABLE 70: LIU COMMON CONTROL REGISTER 5 (ADDRESS = 0X0105)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DS1/E1 LIU
Global
nterrupt
Status
Channel 20
DS1/E1 LIU
Global
nterrupt
Status
Channel 19
DS1/E1 LIU
Global
nterrupt
Status
Channel 18
DS1/E1 LIU
Global
nterrupt
Status
Channel 17
DS1/E1 LIU
Global
nterrupt
Status
Channel 16
DS1/E1 LIU
Global
nterrupt
Status
Channel 15
DS1/E1 LIU
Global
nterrupt
Status
Channel 14
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - Reserved
BIT [6:0] - Global Channel Interrupt Status - Channels 14 to 20
These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If
a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register
is read back, these bit fields will automatically return Low.
TABLE 71: LIU COMMON CONTROL REGISTER 6 (ADDRESS = 0X0106)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DS1/E1 LIU
Global
Interrupt
Status
Channel 27
DS1/E1 LIU
Global
Interrupt
Status
Channel 26
DS1/E1 LIU
Global
Interrupt
Status
Channel 25
DS1/E1 LIU
Global
Interrupt
Status
Channel 24
DS1/E1 LIU
Global
Interrupt
Status
Channel 23
DS1/E1 LIU
Global
Interrupt
Status
Channel 22
DS1/E1 LIU
Global
Interrupt
Status
Channel 21
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - Reserved
BIT [6:0] - Global Channel Interrupt Status - Channels 21 to 27
These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If
a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register
70
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
is read back, these bit fields will automatically return Low.
2.3
RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
The register map for the Receive STS-1/STS-3 TOH Processor block is presented in the Table below.
Additionally, a detailed description of each of the Receive STS-1/STS-3 TOH Processor Block registers is
presented below.
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328, with the Receive STS-1/STS-3 TOH Processor Block highlighted is presented below in
Figure 3.
FIGURE 3. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
TABLE 72: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0202)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
Sync on B1
Unused
No OH
Extract
R/O
R/O
R/O
R/O
R/O
R/W
R/O
R/W
0
0
0
0
0
0
0
0
BIT [7:3] - Unused
BIT 2 - Sync on B1
71
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT 1 - Unused
BIT 0 - No Overhead Data Extract
TABLE 73: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0203)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
SF Defect
Condition
Detect
Enable
SD Defect
Condition
Detect
Enable
DescrambleDisable
Unused
REI-LError
Type
B2 ErrorType
B1 Error
Type
R/O
R/W
R/W
R/W
R/O
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Unused
BIT 6 - Signal Failure (SF) Defect Condition Detect Enable
This READ/WRITE bit-field is used to enable or disable SF Defect Detection and Declaration by the Receive STS1/STS-3 TOH Processor block.
` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to NOT declare nor clear the SF defect condition per
the user-specified SF defect declaration and clearance criteria.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to declare and clear the SF defect condition per the
user-specified SF defect declaration and clearance criteria.
BIT 5 - Signal Degrade (SD) Defect Condition Detect Enable
This READ/WRITE bit-field is used to enable or disable SD Detection and Declaration by the Receive STS-1/STS-3
TOH Processor block.
` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to NOT declare nor clear the SD defect condition per
the user-specified SD defect declaration and clearance criteria.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to declare and clear the SD defect condition per the
user-specified SD defect declaration and clearance criteria.
BIT 4 - De-Scramble Disable
This READ/WRITE bit-field is used to either enable or disable de-scrambling by the Receive STS-1/STS-3 TOH
Processor block, associated with channel N.
` 0 - De-Scrambling is enabled.
` 1 - De-Scrambling is disabled.
BIT 3 - Unused
BIT 2 - REI-L Error Type
This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will count (or tally)
REI-L events, for Performance Monitoring purposes. The user can configure the Receive STS-1/STS-3 TOH Processor
block to increment REI-L events on either a per-bit or per-frame basis.
If the user configures the Receive STS-1/STS-3 TOH Processor block to increment REI-L events on a per-bit basis,
then it will incrememt the Receive STS-1/STS-3 Transport REI-L Error Count register by the value of the lower nibble
within the M0/M1 byte of the incoming STS-1/STS-3 data-stream.
If the user configures the Receive STS-1/STS-3 TOH Processor block to increment REI-L events on a per-frame basis,
then it will increment the Receive STS-1/STS-3 Transport REI-L Error Count register each time it receives an STS1/STS-3 or STS-3 frame, in which the lower nibble of the M0/M1 byte is set to a non-zero value.
` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to count or tally REI-L events on a per-bit basis.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to count or tally REI-L events on a per-frame basis.
BIT 1 - B2 Error Type
This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will count (or tally)
B2 byte errors, for Performance Monitoring purposes. The user can configure the Receive STS-1/STS-3 TOH
Processor block to increment B2 byte errors on either a per-bit or a per-frame basis.
72
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B2 byte errors on a per-bit basis,
then it will increment the Receive Transport B2 Byte Error Count register by the number of bits (within the B2 byte value)
that is in error.
If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B2 byte errors on a per-frame basis,
then it will increment the Receive Transport B2 Byte Error Count register each time it receives an STS-1/STS-3 frame
that contains an erred B2 byte.
` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to count B2 byte errors on a per-bit basis.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to count B2 byte errors on a per-frame basis.
BIT 0 - B1 Error Type
This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will count (or tally)
B1 byte errors, for Performance Monitoring purposes. The user can configure the Receive STS-1/STS-3 TOH
Processor block to increment B1 byte errors on either a per-bit or per-frame basis.
If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B1 byte errors on a per-bit basis,
then it will increment the Receive Transport B1 Byte Error Count register by the number of bits (within the B1 byte value)
that is in error.
If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B1 byte errors on a per-frame basis,
then it will increment the Receive Transport B1 Byte Error Count Register each time it receives an STS-1/STS-3 frame
that contains an erred B1 byte.
` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to count B1 byte errors on a per-bit basis.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to count B1 byte errors on a per-frame basis.
TABLE 74: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0206)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
Section Trace
Section Trace
Message (J0)
Message (J0)
Mismatch
Unstable Defect
Defect Declared
Declared
BIT 0
AIS-L Defect
Declared
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:3] - Unused
BIT 2 - Section Trace Message Mismatch Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the Section Trace Mismatch defect condition. The Receive STS-1/STS-3 TOH Processor block will declare
the Section Trace Message Mismatch defect condition, whenever it accepts a Section Trace Message (via the J0 byte,
within the incoming STS-1/STS-3 data-stream) that differs from the Expected Section Trace Message.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the Section Trace
Message Mismatch Defect Condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Message
Mismatch Defect Condition.
BIT 1 - Section Trace Message Unstable Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the Section Trace Message Unstable Defect condition. The Receive STS-1/STS-3 TOH Processor block will
declare the Section Trace Message Unstable defect condition, whenever the "Section Trace Message Unstable"
counter reaches the value 8. The Receive STS-1/STS-3 TOH Processor block will increment the "Section Trace
Message Unstable" counter for each time that it receives a Section Trace message that differs from the "Expected
Section Trace Message". The Receive STS-1/STS-3 TOH Processor block will clear the "Section Trace Message
Unstable" counter to "0" whenever it has received a given Section Trace Message 3 (or 5) consecutive times
NOTE: The Receive STS-1/STS-3 TOH Processor block will clear the "Section Trace Message Unstable" defect condition
whenever it receives a given Section Trace Message 3 (or 5) consecutive times".
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the Section Trace
73
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Message Unstable defect condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Message
Unstable defect condition
BIT 0 - AIS-L Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the AIS-L (Line AIS) defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the AISL defect condition within the incoming STS-1/STS-3data stream if bits 6, 7 and 8 (e.g., the Least Significant Bits, within
the K2 byte) are set to the value [1, 1, 1] for five consecutive STS-1/STS-3frames.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the AIS-L defect
condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the AIS-L defect condition.
TABLE 75: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0207)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
RDI-L Defect
Declared
S1 Byte
Unstable
Defect
Declared
K1, K2 Byte
Unstable
Defect
Declared
SF Defect
Declared
SD Defect
Declared
LOFDefect
Detected
SEFDefect
Declared
LOSDefect
Declared
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - RDI-L Defect Declared Indicator
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is detecting the
RDI-L (Line-Remote Defect Indicator) defect condition, within the incoming STS-1/STS-3 signal. The Receive STS1/STS-3 TOH Processor block will declare the RDI-L defect condition whenever bits 6, 7 and 8 (e.g., the three least
significant bits) of the K2 byte contains the 1, 1, 0 pattern in 5 consecutive incoming STS-1/STS-3 or STS-3 frames.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the AIS-L defect
condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the AIS-L defect condition..
BIT 6 - S1 Byte Unstable Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the S1 Byte Unstable defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the S1
Byte Unstable defect condition whenever the S1 Byte Unstable Counter reaches the value 32. The Receive STS1/STS-3 TOH Processor block will increment the "S1 Byte Unstable Counter" each time that the it receives an STS1/STS-3 or STS-3 frame that contains an S1 byte that differs from the previously received S1 byte. The Receive STS1/STS-3 TOH Processor block will clear the "S1 Byte Unstable Counter" to "0" when the same S1 byte is received for
8 consecutive STS-1/STS-3 frames.
NOTE: The Receive STS-1/STS-3 TOH Processor block will clear the "S1 Byte Unstable" defect whenever it receives a
given S1 byte, in 8 consecutive STS-1/STS-3 frames.
1. 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the S1 Byte Unstable
Defect Condition.
1. 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the S1 Byte Unstable Defect
Condition.
BIT 5 - K1, K2 Byte Unstable Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the K1, K2 Byte Unstable defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the
K1, K2 Byte Unstable defect condition whenever it fails to receive the same set of K1, K2 bytes, in 12 consecutive
incoming STS-1/STS-3 frames. The Receive STS-1/STS-3 TOH Processor block will clear the "K1, K2 Byte Unstable"
defect whenever it has received a given set of K1, K2 byte values within three consecutive incoming STS-1/STS-3
frames.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the "K1, K2 Byte
74
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Unstable Defect" Condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the "K1, K2 Byte Unstable
Defect" Condition.
BIT 4 - SF (Signal Failure) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the SF defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition
anytime it has determined that the number of B2 byte errors (measured over a user-selected period of time) exceeds a
certain user-specified B2 Byte Error threshold.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the SF Defect condition.
This bit is set to "0" when the number of B2 byte errors (accumulated over a given interval of time) does not exceed the
"SF Defect Declaration" threshold.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the SF Defect condition.
This bit is set to "1" when the number of B2 errors (accumulated over a given interval of time) does exceed the "SF
Defect Declaration" threshold
BIT 3 - SD (Signal Degrade) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the SD defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition
anytime it has determined that the number of B2 byte errors (measured over a user-selected period of time) exceeds a
certain user-specified B2 Byte Error threshold.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the SD Defect condition.
This bit is set to 0 when the number of B2 errors (accumulated over a given interval of time) does not exceed the SD
Declaration threshold.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the SD Defect condition.
This bit is set to 1 when the number of B2 errors (accumulated over a given interval of time) does exceed the SD Defect
Declaration threshold.
BIT 2 - LOF (Loss of Frame) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the LOF defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the LOF defect
condition if it has been declaring the SEF condition for 24 consecutive STS-1/STS-3 frame periods. Once the Receive
STS-1/STS-3 TOH Processor block has declared the LOF defect condition, then the Receive STS-1/STS-3 TOH
Processor block will clear the LOF defect if it has not been declaring the SEF condition for 3ms (or 24 consecutive STS1/STS-3 frame periods).
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the LOF defect condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOF defect condition.
BIT 1 - SEF (Severely Errored Frame) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the SEF defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the SEF defect
condition if it detects Framing Alignment byte errors in four consecutive STS-1/STS-3 frames. Once the Receive TOH
Processor block declares the SEF defect condition, the Receive STS-1/STS-3 TOH Processor block will then clear the
SEF defect condition if it detects two consecutive STS-1/STS-3 frames with un-erred framing alignment bytes. If the
Receive TOH Processor block declares the SEF defect condition for 24 consecutive STS-1/STS-3 frame periods, then
it will declare the LOF defect condition.
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the SEF defect condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the SEF defect condition.
BIT 0 - LOS (Loss of Signal) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently
declaring the LOS (Loss of Signal) defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the
LOS defect condition if it detects LOS_THRESHOLD[15:0] consecutive All Zero bytes in the incoming STS-1/STS-3
data stream.
NOTE: The user can set the LOS_THRESHOLD[15:0] value by writing the appropriate data into the Receive STS1/STS-3 Transport - LOS Threshold Value Register (Address Location= 0x022E and 0x022F).
75
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the LOS defect
condition.
` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOS defect condition.
TABLE 76: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 2 (ADDRESS LOCATION=
0X0209)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Change of
AIS-LDefect
Condition
Interrupt
Status
Change of
RDI-L Defect
Condition
Interrupt
Status
R/O
R/O
R/O
R/O
R/O
R/O
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7: 2] - Unused
BIT 1 - Change of AIS-L (Line AIS) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of AIS-L Defect Condition interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following occurrences.· Whenever the Receive STS-1/STS-3 TOH Processor block declares
the AIS-L defect condition.· Whenever the Receive STS-1/STS-3 TOH Processor block clears the AIS-L defect
condition.
` 0 - Indicates that the Change of AIS-L Defect Condition interrupt has not occurred since the last read of this register.
` 1 - Indicates that the Change of AIS-L Defect Condition interrupt has occurred since the last read of this register.
NOTE: The user can obtain the current state of the AIS-L defect condition by reading the contents of BIT 0 (AIS-L
Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 1 (Address Location=
0x0206).
BIT 0 - Change of RDI-L (Line - Remote Defect Indicator) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of RDI-L Defect Condition interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following occurrences.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the RDI-L defect condition.·
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the RDI-L defect condition.
` 0 - Indicates that the Change of RDI-L Defect Condition interrupt has not occurred since the last read of this register.
` 1 - Indicates that the Change of RDI-L Defect Condition interrupt has occurred since the last read of this register.Note:
NOTE: The user can obtain the current state of the RDI-L defect condition by reading out the state of BIT7 (RDI-L
Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0 (Address Location=
0x0207).
76
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 77: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION=
0X020A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
New S1
ByteInterrupt Status
Change in
S1 Byte
UnstableDefect ConditionInterrupt
Status
Change in
Section
Trace Message Unstable Defect
Condition
Interrupt Status
New Section
Trace Message Interrupt Status
Change in
Section
Trace Message MismatchDefect
Declared
Interrupt Status
Unused
RUR
RUR
RUR
RUR
RUR
R/O
RUR
RUR
0
0
0
0
0
0
0
0
Change in
NEW K1K2
K1, K2 Byte
Byte Value
Unstable
Interrupt Status
Defect Condtion Interrupt
Status
BIT 7 - New S1 Byte Value Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the New S1 Byte Value Interrupt has occurred since the last
read of this register. The Receive STS-1/STS-3 TOH Processor block will generate the New S1 Byte Value Interrupt,
anytime it has accepted a new S1 byte, from the incoming STS-1/STS-3 data-stream.
` 0 - Indicates that the New S1 Byte Value Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the New S1 Byte Value interrupt has occurred since the last read of this register.
NOTE: The user can obtain the value for this most recently accepted value of the S1 byte by reading the Receive STS1/STS-3 Transport S1 Byte Value register (Address Location= 0x0227).
BIT 6 - Change in S1 Byte Unstable Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in S1 Byte Unstable Defect Condition Interrupt
has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this
interrupt in response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the S1 Byte Unstable defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the S1 Byte Unstable defect condition.
` 0 - Indicates that the Change in S1 Byte Unstable Defect Condition Interrupt has occurred since the last read of this
register.
` 1 - Indicates that the Change in S1 Byte Unstable Defect Condition Interrupt has not occurred since the last read of
this register.
NOTE: The user can obtain the current S1 Byte Unstable Defect condition by reading the contents of BIT6 (S1 Byte
Unstable Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0 (Address
Location= 0x0207).
BIT 5 - Change in Section Trace Message Unstable Defect condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in Section Trace Message Unstable defect
condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block
will generate this interrupt in response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Unstable
defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clear the Section Trace Message Unstable defect
condition.
` Indicates that the Change in Section Trace Message Unstable defect condition interrupt has not occurred since the
last read of this register.
` 1 - Indicates that the Change in Section Trace Message Unstable defect condition interrupt has occurred since the
last read of this register.
BIT 4 - New Section Trace Message Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the New Section Trace Message interrupt has occurred since
77
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it has
accepted a new Section Trace Message within the incoming STS-1/STS-3 data-stream.
` 0 - Indicates that the New Section Trace Message Interrupt has not occurred since the last read of this register.
` 1 - Indicates that the New Section Trace Message Interrupt has occurred since the last read of this register.
NOTE: The user can read out the contents of the Receive Section Trace Message Buffer, which is located at Address
Locations 0x0400 through 0x04FF).
BIT 3 - Change in Section Trace Message Mismatch Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in Section Trace Mismatch Defect Condition
interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate
this interrupt in response to either of the following events.· Whenever the Receive STS-1/STS-3 TOH Processor block
declares the Section Trace Message Mismatch defect condition· Whenever the Receive STS-1/STS-3 TOH Processor
block clears the Section Trace Mismatch defect condition.
` 0 - Indicates that the Change in Section Trace Message Mismatch Defect Condition interrupt has not occurred since
the last read of this register.
` 1 - Indicates that the Change in Section Trace Message Mismatch Defect Condition interrupt has occurred since the
last read of this register.
NOTE: The user can determine whether the Section Trace Message Mismatch condition is currently cleared or
declared by reading the state of BIT 2 (Section Trace Message Mismatch Defect Declared) within the Receive
STS-1/STS-3 Transport Status Register - Byte 1 (Address Location= 0x0206).
BIT 2 - Unused
BIT 1 - Change in K1, K2 Byte Unstable Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in K1, K2 Byte Unstable Defect Condition
interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate
this interrupt in response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the K1, K2 Byte Unstable Defect
condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the K1, K2 Byte Unstable Defect condition.
` 0 - Indicates that the Change of K1, K2 Byte Unstable Defect Condition interrupt has NOT occurred since the last read
of this register.
` 1 - Indicates that the Change of K1, K2 Byte Unstable Defect Condition interrupt has occurred since the last read of
this register.
NOTE: The user can determine whether the K1, K2 Byte Unstable Defect Condition is currently being declared or
cleared by reading out the contents of BIT 5 (K1, K2 Byte Unstable Defect Declared), within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207).
BIT 0 - New K1, K2 Byte Value Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the New K1, K2 Byte Value Interrupt has occurred since the
last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt whenever its has
accepted a new set of K1, K2 byte values from the incoming STS-1/STS-3 data-stream
` 0 - Indicates that the New K1, K2 Byte Value Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the New K1, K2 Byte Value Interrupt has occurred since the last read of this register.
NOTE: The user can obtain the contents of the new K1 byte by reading out the contents of the Receive STS-1/STS-3
Transport K1 Byte Value Register (Address Location= 0xN11F). Further, the user can also obtain the contents
of the new K2 byte by reading out the contents of the Receive STS-1/STS-3 Transport K2 Byte Value Register
(Address Location= 0x0223).
78
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 78: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION=
0X020B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
SF Defect
ConditionInterrupt Status
Change of
SD Defect
Condition
Interrupt Status
Detection of
REI-L Event
Error Interrupt Status
Detection of
B2 Byte
Error Interrupt Status
Detection of
B1 Byte
Error Interrupt Status
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
Change of
Change of
Change of
LOF Defect
SEF Defect
LOS Defect
Condition
Interrupt StaCondition
tus
Interrupt StaInterrupt Status
tus
BIT 7 - Change of Signal Failure (SF) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of SF Defect Condition Interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the SF Defect Condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the SF Defect Condition.
` 0 - Indicates that the Change of SF Defect Condition Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of SF Defect Condition Interrupt has occurred since the last read of this register.
NOTE: The user can determine whether or not the SF defect condition is currently being declared by reading out the
state of BIT 4( SF Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0
(Address Location= 0x0207).
BIT 6 - Change of Signal Degrade (SD) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of SD Defect Condition Interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following events.
•
Whenver the Receive STS-1/STS-3 TOH Processor block declares the SD Defect Condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the SD Defect Condition.
` 0 - Indicates that the Change of SD Defect Condition Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of SD Defect Condition Interrupt has occurred since the last read of this register.
NOTE: The user can determine whether or not the SD Defect condition is currently being declareds by reading out the
state of BIT 3 (SD Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0
(Address Location= 0x0207).
BIT 5 - Detection of REI-L (Line - Remote Error Indicator) Event Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of REI-L Event Interrupt has occurred since the
last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it detects
an REI-L event within the incoming STS-1/STS-3 data-stream.
` 0 - Indicates that the Detection of REI-L Event Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of REI-L Event Interrupt has occurred since the last read of this register.
BIT 4 - Detection of B2 Byte Error Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of B2 Byte Error Interrupt has occurred since
the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it
detects a B2 byte error within the incoming STS-1/STS-3 data-stream.
` 0 - Indicates that the Detection of B2 Byte Error Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of B2 Byte Error Interrupt has occurred since the last read of this register.
BIT 3 = Detection of B1 Byte Error Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of B1 Byte Error Interrupt has occurred since
the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it
79
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
detects a B1 byte error within the incoming STS-1/STS-3 data-stream.
` 0 - Indicates that the Detection of B1 Byte Error Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of B1 Byte Error Interrupt has occurred since the last read of this register
BIT 2 - Change of Loss of Frame (LOF) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of LOF Defect Condition interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the LOF Defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the LOF Defect condition.
` 0 - Indicates that the Change of LOF Defect Condition interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of LOF Defect Condition interrupt has occurred since the last read of this register.
NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring
the LOF defect condition by reading out the state of BIT 2 (LOF Defect Declared) within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207).
BIT 1 - Change of SEF Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of SEF Defect Condition Interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the SEF defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the SEF defect condition.
` 0 - Indicates that the Change of SEF Defect Condition Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of SEF Defect Condition Interrupt has occurred since the last read of this register.
NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring
the SEF defect condition by reading out the state of BIT 1 (SEF Defect Declared) within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207).
BIT 0 - Change of Loss of Signal (LOS) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of LOS Defect Condition interrupt has occurred
since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in
response to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the LOS defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the LOS defect condition.
` 0 - Indicates that the Change of LOS Defect Condition Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of LOS Defect Condition Interrupt has occurred since the last read of this register.
NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring
the LOS defect condition by reading out the contents of BIT 0 (LOS Defect Declared) within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207).
TABLE 79: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 2 (ADDRESS LOCATION=
0X020D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Change of
AIS-LDefect
Condition
Interrupt
Enable
Change of
RDI-LDefect
Condition
Interrupt
Enable
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:2] - Unused
80
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT 1- Change of AIS-L (Line AIS) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of AIS-L Defect Condition interrupt. If this
interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions.
•
When the Receive STS-1/STS-3 TOH Processor block declares the AIS-L defect condition.·
•
When the Receive STS-1/STS-3 TOH Processor block clears the AIS-L defect condition.
` 0 - Disables the Change of AIS-L Defect Condition Interrupt.
` 1 - Enables the Change of AIS-L Defect Condition Interrupt.
BIT 0 - Change of RDI-L (Line Remote Defect Indicator) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of RDI-L Defect Condition interrupt. If this
interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions.·
When the Receive STS-1/STS-3 TOH Processor block declares the RDI-L defect condition.· When the Receive STS1/STS-3 TOH Processor block clears the RDI-L defect condition.
` 0 - Disables the Change of RDI-L Defect Condition Interrupt.
` 1 - Enables the Change of RDI-L Defect Condition Interrupt.
TABLE 80: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS LOCATION=
0X020E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
New S1 Byte
Interrupt
Enable
Change in
S1 Byte
Unstable
Defect ConditionInterrupt Enable
Change in
Section
Trace Message Unstable Defect
Condition
Interrupt
Enable
New Section
Trace Message Interrupt Enable
Change in
Section
Trace Message Mismatch Defect
Condition
Interrupt
Enable
Unused
Change in
K1, K2 Byte
Unstable
Defect ConditionInterrupt Enable
New K1K2
Byte Value
Interrupt
Enable
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - New S1 Byte Value Interrupt Enable
This READ/WRITE bit-field is used to enable or disable the New S1 Byte Value Interrupt.
If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it
receives and accepts a new S1 byte value. The Receive STS-1/STS-3 TOH Processor block will accept a new S1 byte
after it has received it for 8 consecutive STS-1/STS-3 frames.
` 0 - Disables the New S1 Byte Value Interrupt.
` 1 - Enables the New S1 Byte Value Interrupt.
BIT 6 - Change in S1 Byte Unstable Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change in S1 Byte Unstable Defect Condition
Interrupt..
If the user enables this bit-field, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt in
response to either of the following conditions
•
When the Receive STS-1/STS-3 TOH Processor block declares the S1 Byte Unstable defect condition
•
When the Receive STS-1/STS-3 TOH Processor block clears the S1 Byte Unstable defect condition.
` 0 - Disables the Change in S1 Byte Unstable Defect Condition Interrupt.
` 1 - Enables the Change in S1 Byte Unstable Defect Condition Interrupt.
BIT 5 - Change in Section Trace Message Unstable defect condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change in Section Trace Message Unstable Defect
Condition Interrupt.
81
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt in response
to either of the following conditions.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Unstable
defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the Section Trace Message Unstable
defect condition.
` 0 - Disable the Change of Section Trace Message Unstable defect condition Interrupt.
` 1 - Enables the Change of Section Trace Message Unstable defect condition Interrupt.
BIT 4 - New Section Trace Message Interrupt Enable
This READ/WRITE bit-field is used to enable or disable the New Section Trace Message interrupt.
If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it
receives and accepts a new Section Trace Message within the incoming STS-1/STS-3 data-stream. The Receive STS1/STS-3 TOH Processor block will accept a new Section Trace Message after it has received it 3 (or 5) consecutive
times.
` 0 - Disables the New Section Trace Message Interrupt.
` 1 - Enables the New Section Trace Message Interrupt.
BIT 2 - Unused
BIT 3 - Change in Section Trace Mismatch Defect Condition interrupt enable:
This READ/WRITE bit-field is used to either enable or disable the Change in Section Trace Mismatch defect condition
interrupt.
If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt in response
to either of the following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Mismatch
Defect condition.
•
whenever the Receive STS-1/STS-3 TOH Processor block clears the Section Trace Message Mismatch
defect condition.
NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring
the Section Trace Message Mismatch defect condition by reading the state of BIT 2 (Section Trace Message
Mismatch Defect Condition Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 1
(Address Location= 0x0206).
BIT 1 - Change of K1, K2 Byte Unstable Defect Condition - Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of K1, K2 Byte Unstable defect condition
interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an Interrupt in
response to either of the following events.a.Whenever the Receive STS-1/STS-3 TOH Processor block declares the K1,
K2 Byte Unstable defect condition. b.Whenever the Receive STS-1/STS-3 TOH Processor block clears the K1, K2 Byte
Unstable defect condition.
` 0 - Disables the Change of K1, K2 Byte Unstable Defect Condition Interrupt.
` 1 - Enables the Change of K1, K2 Byte Unstable Defect Condition Interrupt.
BIT 0 - New K1, K2 Byte Value Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the New K1, K2 Byte Value Interrupt. If this interrupt is
enabled, then the Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it receives and
accepts a new K1, K2 byte value. The Receive STS-1/STS-3 TOH Processor block will accept a new K1, K2 byte value,
after it has received it within 3 (or 5) consecutive STS-1/STS-3 frames.
` 0 - Disables the New K1, K2 Byte Value Interrupt.
` 1 - Enables the New K1, K2 Byte Value Interrupt.
82
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 81: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION=
0X020F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
SF DefectCondition
Interrupt
Enable
Change of
SD Defect
Condition
Interrupt
Enable
Detection of
REI-L Event
Interrupt
Enable
Detection of
B2 Byte
Error Interrupt Enable
Detection of
B1 Byte
Error Interrupt Enable
Change of
LOF Defect
Condition
Interrupt
Enable
Change of
SEF Defect
Condition
Interrupt
Enable
Change of
LOS Defect
Condition
Interrupt
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Change of Signal Failure (SF) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of Signal Failure (SF) Defect Condition
Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to any of the following
events.
•
Whenever the Receive STS-1/STS-3 TOH Processor block declares the SF defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the SF defect condition.
` 0 - Disables the Change of SF Defect Condition Interrupt.
` 1 - Enables the Change of SF Defect Condition Interrupt.
BIT 6 - Change of Signal Degrade (SD) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of Signal Degrade (SD) Defect Condition
Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the
following events.
•
Whenever the Receive STS-1/STS-3 TOH Processor blolck declares the SD defect condition.
•
Whenever the Receive STS-1/STS-3 TOH Processor block clears the SD defect condition.
` 0 - Disables the Change of SD Defect Condition Interrupt.
` 1 - Enables the Change of SD Defect Condition Interrupt.
BIT 5 - Detection of REI-L (Line - Remote Error Indicator) Event Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of REI-L Event interrupt. If this interrupt is
enabled, then the XRT86SH328 will generate an interrupt anytime the Receive STS-1/STS-3 TOH Processor block
detects an REI-L condition within the incoming STS-1/STS-3 data-stream.
` 0 - Disables the Detection of REI-L Event Interrupt.
` 1 - Enables the Detection of REI-L Event Interrupt.
BIT 4 - Detection of B2 Byte Error Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of B2 Byte Error Interrupt. If this interrupt
is enabled, then the XRT86SH328 will generate an interrupt anytime the Receive STS-1/STS-3 TOH Processor block
detects a B2 byte error within the incoming STS-1/STS-3 data-stream.
` 0 - Disables the Detection of B2 Byte Error Interrupt.
` 1 - Enables the Detection of B2 Byte Error Interrupt.
BIT 3 - Detection of B1 Byte Error Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Detection of B1 Byte Error Interrupt. If this interrupt
is enabled, then the XRT86SH328 will generate an interrupt anytime the Receive STS-1/STS-3 TOH Processor block
detects a B1 byte error within the incoming STS-1/STS-3 data-stream.
` 0 - Disables the Detection of B1 Byte Error Interrupt.
` 1 - Enables the Detection of B1 Byte Error Interrupt.
BIT 2 - Change of Loss of Frame (LOF) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of LOF Defect Condition interrupt. If this
83
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions
•
When the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition
•
When the Receive STS-1/STS-3 TOH Processor block clears the LOF defect condition.
` 0 - Disables the Change of LOF Defect Condition Interrupt.
` 1 - Enables the Change of LOF Defect Condition Interrupt.
BIT 1 - Change of SEF Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of SEF Defect Condition Interrupt. If this
interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions.
•
When the Receive STS-1/STS-3 TOH Processor block declares the SEF defect condition.
•
When the Receive STS-1/STS-3 TOH Processor block clears the SEF defect condition.
` 0 - Disables the Change of SEF Defect Condition Interrupt.
` 1 - Enables the Change of SEF Defect Condition Interrupt.
BIT 0 - Change of Loss of Signal (LOS) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of LOF Defect Condition interrupt. If this
interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions.
•
When the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition.
•
When the Receive STS-1/STS-3 TOH Processor block clears the LOF defect condition.
` 0 - Disables the Change of LOF Defect Condition Interrupt.
` 1 - Enables the Change of LOF Defect Condition Interrupt.
TABLE 82: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS
LOCATION= 0X0210)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B1_Byte_Error_Count[31:24]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B1 Byte Error Count - MSB
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes
2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a B1 byte errorwithin the incoming STS-1/STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor Block is configured to count B1 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming
STS-1/STS-3 frame) that are in error
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B1 byte.
TABLE 83: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS
LOCATION= 0X0211)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B1_Byte_Error_Count[23:16]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
84
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT [7:0] - B1 Byte Error Count (Bits 23 through 16)
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes
3, 1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a B1 byte error.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming
STS-1/STS-3 frame) that are in error.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B1 byte.
TABLE 84: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS
LOCATION= 0X0212)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B1_Byte_Error_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B1 Byte Error Count - (Bits 15 through 8)
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes
3, 2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a B1 byte error.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming
STS-1/STS-3 frame) that are in error
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B1 byte.
TABLE 85: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS
LOCATION= 0X0213)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B1_Byte_Error_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B1 Byte Error Count - LSB
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes
3 through 1, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a B1 byte error.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor Block is configured to count B1 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming
STS-1/STS-3 frame) that are in error.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B1 byte.
85
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 86: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS
LOCATION= 0X0214)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B2_Byte_Error_Count[31:24]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B2 Byte Error Count - MSB
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B2 Byte Error Count Register - Bytes
2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a B2 byte (or BIP-24) error within the incoming STS-1/STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming
STS-1/STS-3 frame) that are in error.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B2 byte or errered BIP-24.
TABLE 87: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS
LOCATION= 0X0215)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B2_Byte_Error_Count[23:16]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B2 Byte Error Count (Bits 23 through 16)
This RESET-upon-READ register, along with Receive Transport - B2 Byte Error Count Register - Bytes 3, 1 and 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a
B2 byte or BIP-24 error within the incoming STS-1/STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming
STS-1/STS-3 frame) that are in error.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B2 byte or erred BIP-24.
TABLE 88: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS
LOCATION= 0X0216)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B2_Byte_Error_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B2 Byte Error Count - (Bits 15 through 8)
86
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This RESET-upon-READ register, along with Receive Transport - B2 Byte Error Count Register - Bytes 3, 2 and 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a
B2 byte or BIP-24 error within the incoming STS-1/STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processror block is configured to count B2 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming
STS-1/STS-3 frame) that are in error.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B2 byte or erred BIP-24.
TABLE 89: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS
LOCATION= 0X0217)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B2_Byte_Error_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B2 Byte Error Count - LSB
This RESET-upon-READ register, along with Receive Transport - B2 Byte Error Count Register - Bytes 3 through 1,
function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a
B2 byte or BIP-24 error within the incoming STS-1/STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit
basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming
STS-1/STS-3 frame) that are in error.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains
an erred B2 byte or erred BIP-24.
TABLE 90: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION =
0X0218)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-L_Event_Count[31:24]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-L Event Count - MSB
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 2
through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a Line - Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis,
then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte within each
incoming STS-1/STS-3 frame.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that
contains a non-zero REI-L value.
87
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 91: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION=
0X0219)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-L_Event_Count[23:16]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-L Event Count (Bits 23 through 16)
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 3,
1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a Line - Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis,
then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte (or the
contents within the M1 byte) within each incoming STS-1 (or STS-3) frame.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that
contains a non-zero REI-L value.
TABLE 92: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION=
0X021A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-L_Event_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-L Event Count - (Bits 15 through 8)
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 3,
2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a Line -Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis,
then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte (or the
contents within the M1 byte) within each incoming STS-1 (or STS-3) frame.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that
contains a non-zero REI-L value.
TABLE 93: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION=
0X021B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-L_Event_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-L Event Count - LSB
This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 3
88
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
through 1, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block
detects a Line - Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream.
NOTES:
1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis,
then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte (or the
contents within the M1 byte) within each incoming STS-1 (or STS-3) frame.
2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame
basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that
contains a non-zero REI-L value.
TABLE 94: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K1 BYTE VALUE REGISTER (ADDRESS LOCATION=
0X021F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Filtered_K1_Byte_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0]Filtered/Accepted K1 Byte Value
These READ-ONLY bit-fields contain the value of the most recently filtered K1 byte value that the Receive STS-1/STS3 TOH Processor block has received. These bit-fields are valid if the K1/K2 pair (to which it belongs) has been received
for 3 consecutive STS-1 or STS-3 frames.
This register should be polled by Software in order to determine various APS codes.
TABLE 95: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K2 BYTE VALUE REGISTER (ADDRESS LOCATION=
0X0223)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Filtered_K2_Byte_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0]Filtered/Accepted K2 Byte Value
These READ-ONLY bit-fields contain the value of the most recently filtered K2 Byte value that the Receive STS-1/STS3 TOH Processor block has received. These bit-fields are valid if the K1/K2 pair (to which it belongs) has been received
for 3 consecutive STS-1 or STS-3 frames.
This register should be polled by Software in order to determine various APS codes.
TABLE 96: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED S1 BYTE VALUE REGISTER (ADDRESS LOCATION=
0X0227)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Filtered_S1_Byte_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Filtered/Accepted S1 Byte Value
These READ-ONLY bit-fields contain the value of the most recently filtered S1 byte value that the Receive STS-1/STS3 TOH Processor block has received. These bit-fields are valid if it has been received for 8 consecutive STS-1 or STS3 frames.
89
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 97: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE IN-SYNC THRESHOLD REGISTER (ADDRESS = 0X022B)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
FRPATOUT[1:0]
BIT 1
FRPATIN[1:0]
BIT 0
Unused
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/O
0
0
0
0
0
0
0
0
BIT [7:5] - Unused
BIT [4:3] - FRPATOUT[1:0]
BIT [2:1] - FRPATIN[1:0]
BIT 0 - Unused
TABLE 98: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - MSB (ADDRESS LOCATION= 0X022E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LOS_THRESHOLD[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - LOS Threshold Value - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - LOS Threshold Value - LSB
register is used specify the number of consecutive (All Zero) bytes that the Receive STS-1/STS-3 TOH Processor block
must detect (within the incoming STS-1/STS-3 data-stream) before it can declare the LOS defect condition.
NOTE: This register contains the MSB (Most Significant Byte) of this 16-bit expression.
TABLE 99: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - LSB (ADDRESS LOCATION= 0X022F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LOS_THRESHOLD[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - LOS Threshold Value - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - LOS Threshold Value - MSB
register is used to specify the number of consecutive (All Zero) bytes that the Receive STS-1/STS-3 TOH Processor
block must detect (within the incoming STS-1/STS-3 data-stream) before it can declare the LOS defect condition.
NOTE: This register contains the LSB (Least Significant Byte) of this 16-bit expression.
TABLE 100: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 2 (ADDRESS
LOCATION= 0X0231)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_SET_MONITOR_WINDOW[23:16]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_SET_MONITOR_INTERVAL - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Monitor Interval - Byte
90
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure)
Defect Declaration.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1/STS-3 signal in order to
determine if it should declare the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Declaration monitoring period. If, during this SF Defect Declaration Monitoring Period, the Receive
STS-1/STS-3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive
Transport SF SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect
condition.
NOTES:
1. The value that the user writes into these three (3) SF Set Monitor Window registers, specifies the
duration of the SF Defect Declaration Monitoring Period, in terms of ms.
2. This particular register byte contains the MSB (most significant byte) value of the three registers that
specify the SF Defect Declaration Monitoring Period.
TABLE 101: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 1 (ADDRESS
LOCATION= 0X0232)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_SET_MONITOR_WINDOW[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_SET_MONITOR_INTERVAL (Bits 15 through 8)
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Monitor Interval - Byte
2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure)
Defect Declaration.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1/STS-3 signal in order to
determine if it should declare the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Declaration Monitoring Period. If, during this SF Defect Declaration Monitoring Period the Receive
STS-1/STS-3 TOH Processor block accumulate more B2 byte (or BIP-24) errors than that specified within the Receive
STS-1/STS-3 Transport SF SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare
the SF defect condition.
NOTE: The value that the user writes into these three (3) SF Set Monitor Window registers, specifies the duration of
the SF Defect Declaration Monitoring Period, in terms of ms.
TABLE 102: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 0 (ADDRESS
LOCATION= 0X0233)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_SET_MONITOR_WINDOW[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_SET_MONITOR_INTERVAL - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Monitor Interval - Byte 2 and
Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) Defect Declaration.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1/STS-3 signal in order to determine
if it should declare the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the user-specified SF
Defect Declaration Monitoring Period. If, during this SF Defect Declaration Monitoring Period, the Receive STS-1/STS-3
TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3
Transport SF SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition.
91
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
NOTES:
1. The value that the user writes into these three (3) SF Set Monitor Window registers, specifies the
duration of the SF Defect Declaration Monitoring Period, in terms of ms.
2. This particular register byte contains the LSB (least significant byte) value of the three registers that
specify the SF Defect Declaration Monitoring period.
TABLE 103: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 1 (ADDRESS LOCATION=
0X0236)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_SET_THRESHOLD[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_SET_THRESHOLD - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Threshold - Byte 0
registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH
Processor block to declare the SF (Signal Failure) Defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SF defect condition, it will
accumulate B2 byte (or BIP-24) errors throughout the SF Defect Declaration Monitoring Period. If the number of
accumulated B2 byte (or BIP-24) errors exceeds that value, which is programmed into this and the Receive STS-1/STS3 Transport SF SET Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block will declare the
SF defect condition.
NOTE: This particular register byte contains the MSB (most significant byte) value of this 16-bit expression.
TABLE 104: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 0 (ADDRESS LOCATION=
0X0237)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_SET_THRESHOLD[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_SET_THRESHOLD - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Threshold - Byte 1
registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH
Processor block to declare the SF (Signal Failure) Defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SF defect condition, it will
accumulate B2 byte (or BIP-24) errors throughout the SF Defect Monitoring Period. If the number of accumulated B2
byt (or BIP-24)e errors exceeds that which has been programmed into this and the Receive STS-1/STS-3 Transport SF
SET Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect
condition.
TABLE 105: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 1 (ADDRESS
LOCATION= 0X023A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_CLEAR_THRESHOLD[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
92
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT [7:0] - SF_CLEAR_THRESHOLD - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF CLEAR Threshold - Byte 0
registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive
STS-1/STS-3 TOH Processor block to clear the SF (Signal Failure) defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SF defect condition, it will accumulate
B2 byte (or BIP-24) errors throughout the SF Defect Clearance Monitoring Period. If the number of accumulated B2
byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport SF CLEAR
Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block clear the SF defect condition.
TABLE 106: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 0 (ADDRESS
LOCATION= 0X023B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_CLEAR_THRESHOLD[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_CLEAR_THRESHOLD - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF CLEAR Threshold - Byte 1
registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive
STS-1/STS-3 TOH Processor block to clear the SF (Signal Failure) defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SF defect condition, it will accumulate
B2 byte (or BIP-24) errors throughout the SF Defect Clearance Monitoring Period. If the number of accumulated B2
byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport SF CLEAR
Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will clear the SF defect condition.
TABLE 107: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 2 (ADDRESS
LOCATION= 0X023D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_SET_MONITOR_WINDOW[23:16]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - SD_SET_MONITOR_INTERVAL - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Monitor Interval - Byte 1
and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect
declaration.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should declare the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the user-specified
SD Defect Declaration monitoring period. If, during this SD Defect Declaration Monitoring period, the Receive STS-1/STS3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3
Transport SD SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition.
NOTES:
1. The value that the user writes into these three (3) SD Set Monitor Window registers, specifies the
duration of the SD Defect Declaration Monitoring Period, in terms of ms.
2. This particular register byte contains the MSB (Most significant byte) value of the three registers that
specify the SD Defect Declaration Monitoring Period.
93
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 108: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 1 (ADDRESS
LOCATION= 0X023E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_SET_MONITOR_WINDOW[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - SD_SET_MONITOR_INTERVAL - Bits 15 through 8
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Monitor Interval - Byte
2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade)
defect declaration.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine it it should declare the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Declaration Monitoring Period. If, during this SD Defect Declaration Monitoring Period the Receive
STS-1/STS-3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive
STS-1/STS-3 Transport SD SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare
the SD defect condition.
NOTE: The value that the user writes into these three (3) SD Set Monitor Window registers, specifies the duration of
the SD Defect Declaration Monitoring Period, in terms of ms.
TABLE 109: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 0 (ADDRESS
LOCATION= 0X023F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_SET_MONITOR_WINDOW[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - SD_SET_MONITOR_INTERVAL - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Monitor Interval - Byte
2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade)
defect declaration.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should declare the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspeciifed SD Defect Declaration Monitoring Period. If, during this SD Defect Declaration Monitoring Period, the Receive
STS-1/STS-3 TOH Processor block accmulattes more B2 byte (or BIP-24) errors than that specified within the Receive
STS-1/STS-3 Transport SD SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare
the SD defect condition.
NOTES:
1. The value that the user writes into these three (3) SD Set Monitor Window registers, specifies the
duration of the SD Defect Declaration Monitoring Period, in terms of ms.
2. This particular register byte contains the LSB (least significant byte) value of the three registers that
specify the SD Defect Declaration Monitoring period.
94
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 110: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 1 (ADDRESS LOCATION=
0X0242)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_SET_THRESHOLD[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_SET_THRESHOLD - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Threshold - Byte 0
registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH
Processor block to declare the SD (Signal Degrade) defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SD defect condition, it will
accumulate B2 byte (or BIP-24) errors throughout the SD Defect Declaration Monitoring Period. If the number of
accumulated B2 byte (or BIP-24) errors exceeds that value, which is programmed into this and the Receive STS-1/STS3 Transport SD SET Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block will declare the
SD defect condition.
TABLE 111: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 0 (ADDRESS LOCATION=
0X0243)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_SET_THRESHOLD[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_SET_THRESHOLD - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Threshold - Byte 1
registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH
Processor block to declare an SD (Signal Degrade) defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SD defect condition, it will
accumulate B2 byte (or BIP-24) errors throughout the SD Defect Monitoring Period. If the number of accumulated B2
byte (or BIP-24) errors exceeds that which has been programmed into this and the Receive STS-1/STS-3 Transport SD
SET Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect
condition.
TABLE 112: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS
LOCATION= 0X0246)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_CLEAR_THRESHOLD[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_CLEAR_THRESHOLD - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD CLEAR Threshold - Byte 0
registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive
STS-1/STS-3 TOH Processor block to clear the SD (Signal Degrade) defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SD defect condition, it will
accumulate B2 byte (or BIP-24) errors throughout the SD Defect Clearance Monitoring Period. If the number of
accumulated B2 byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport
95
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
SD CLEAR Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect
condition.
TABLE 113: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS
LOCATION= 0X0247)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_CLEAR_THRESHOLD[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_CLEAR_THRESHOLD - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD CLEAR Threshold - Byte 1
registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive
STS-1/STS-3 TOH Processor block to clear the SD (Signal Degrade) defect condition.
When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SD defect condition, it will
accumulate B2 byte (or BIP-24) errors throughout the SD Defect Clearance Monitoring Period. If the number of
accumulated B2 byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport
SD CLEAR Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect
condition.
TABLE 114: RECEIVE STS-1/STS-3 TRANSPORT - FORCE SEF DEFECT CONDITION REGISTER (ADDRESS
LOCATION= 0X024B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
BIT 0
SEF FORCE
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/W
0
0
0
0
0
0
0
0
BIT [7:1] - Unused
BIT 0 - SEF Defect Condition FORCE
This READ/WRITE bit-field is used to force the Receive STS-1/STS-3 TOH Processor block (within the corresponding
Channel) to declare the SEF defect condition. The Receive STS-1/STS-3 TOH Processor block will then attempt to
reacquire framing.
Writing a 1 into this bit-field configures the Receive STS-1/STS-3 TOH Processor block to declare the SEF defect. The
Receive STS-1/STS-3 TOH Processor block will automatically set this bit-field to 0 once it has reacquired framing (e.g.,
has detected two consecutive STS-1 or STS-3 frames with the correct A1 and A2 bytes).
TABLE 115: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER CONTROL
REGISTER (ADDRESS LOCATION= 0X024F)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
Receive Section Trace
Message
Buffer Read
Select
Receive Section Trace
Message
Accept
Threshold
Section Trace
Message
Alignment
Type
BIT 1
BIT 0
Receive Section Trace Message Length[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:5] - Unused
96
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT 4Receive Section Trace Message Buffer Read Selection
This READ/WRITE bit-field is used to specify which of the following Receive Section Trace Message buffer segments
to read.
•
The Actual Receive Section Trace Message Buffer which contains the contents of the most recently received
(and accepted) Section Trace Message via the incoming STS-1 or STS-3 data-stream.
•
The Expected Receive Section Trace Message Buffer which contains the contents of the Section Trace
Message that the user expects to receive. The contents of this particular buffer are usually specified by the
user.
` 0 - Executing a READ to the Receive Section Trace Message Buffer address space, will return contents within the
Actual Receive Section Trace Message buffer.
` 1 - Executing a READ to the Receive Section Trace Message Buffer address space will return contents within the
Expected Receive Section Trace Message Buffer.
NOTE: In the case of the Receive STS-3 TOH Processor block, the Receive Section Trace Message Buffer is located
at Address Location 0x0400 through 0x043F.
BIT 3 - Receive Section Trace Message Accept Threshold
This READ/WRITE bit-field is used to select the number of consecutive times that the Receive STS-1/STS-3 TOH
Processor block must receive a given Section Trace Message, before it is accepted, as described below. Once a given
Section Trace Message has been accepted then it can be read out of the Actual Receive Section Trace Message Buffer.
` 0 - The Receive STS-1/STS-3 TOH Processor block accepts the Section Trace Message after it has received it the
third time in succession.
` 1 - The Receive STS-1/STS-3 TOH Processor block accepts the Section Trace Message after it has received in the
fifth time in succession.
BIT 2 - Section Trace Message Alignment Type
This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will locate the
boundary of the Section Trace Message within the incoming STS-1 or STS-3 data-stream, as indicated below.
` 0 - Message boundary is indicated by Line Feed.
` 1 - Message boundary is indicated by the presence of a 1 in the MSB of the first byte (within the Section Trace
Message).
BIT [1:0] - Receive Section Trace Message Length[1:0]
These READ/WRITE bit-fields are used to specify the length of the Section Trace Message that the Receive STS1/STS-3 TOH Processor block will receive. The relationship between the content of these bit-fields and the
corresponding Receive Section Trace Message Length is presented below
Trace Message Length
RECEIVE SECTION TRACE MESSAGE
LENGTH[1:0]
RESULTING RECEIVE SECTION TRACE MESSAGE LENGTH (IN TERMS OF
BYTES)
00
1 Byte
01
16 Bytes
10/11
64 Bytes
TABLE 116: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 1 (ADDRESS
LOCATION= 0X0252)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_BURST_TOLERANCE[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
97
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT [7:0] - SD_BURST_TOLERANCE - MSB
These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SD BURST Tolerance - Byte
0 registers are used to specify the maximum number of B2 byte (or BIP-24) errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame
period), when determining whether or not to declare the SD (Signal Degrade) defect condition.
NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive
STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SD defect
condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor
block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SD defect condition.
TABLE 117: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 0 (ADDRESS
LOCATION= 0X0253)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_BURST_TOLERANCE[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_BURST_TOLERANCE - LSB
These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SD BURST Tolerance - Byte
1 registers are used to specify the maximum number of B2 byte (or BIP-24) errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame
period), when determining whether or not to declare the SD (Signal Degrade) defect condition.
NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive
STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SD defect
condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor
block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SD defect condition.
TABLE 118: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 1 (ADDRESS
LOCATION= 0X0256)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_BURST_TOLERANCE[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_BURST_TOLERANCE - MSB
These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SF BURST Tolerance - Byte
0 registers are used to specify the maximum number of B2 byte (or BIP-24) errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame
period), when determining whether or not to declare the SF (Signal Failure) defect condition.
NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive
STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SF defect
condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor
block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SF defect condition.
98
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 119: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 0 (ADDRESS
LOCATION= 0X0257)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_BURST_TOLERANCE[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_BURST_TOLERANCE - LSB
These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SF BURST Tolerance - Byte
1 registers are used to specify the maximum number of B2 byte (or BIP-24)errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame
period), when determining whether or not to declare the SF (Signal Failure) defect condition.
NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive
STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SF defect
condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor
block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SF defect condition.
TABLE 120: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS
LOCATION= 0X0259)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_CLEAR_MONITOR_WINDOW[23:16]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_CLEAR_MONITOR_INTERVAL - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD Clear Monitor Interval - Byte
1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade)
defect clearance.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should clear the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Clearance Monitoring period. If, during this SD Defect Clearance Monitoring period, the Receive
STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive
STS-1/STS-3 Transport SD Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear
the SD defect condition.
NOTES:
1. The value that the user writes into these three (3) SD Clear Monitor Window Registers, specifies the
duration of the SD Defect Clearance Monitoring Period, in terms of ms.
2. This particular register byte contains the MSB (Most significant byte) value of the three registers that
specifiy the SD Defect Clearance Monitoring period.
TABLE 121: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS
LOCATION= 0X025A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SD_CLEAR_MONITOR_WINDOW[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SD_CLEAR_MONITOR_INTERVAL - Bits 15 through 8
99
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD Clear Monitor Interval - Byte
2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade)
defect clearance.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should clear the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Clearance Monitoring period. If, during this SD Defecf Clearance Monitoring Period, the Receive
STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive
STS-1/STS-3 Transport SD Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear
the SD defect condition.
NOTE: The value that the user writes into these three (3) SD Clear Monitor Window Registers, specifies the duration of
the SD Defect Clearance Monitoring Period, in terms of ms.
TABLE 122: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS
LOCATION= 0X025B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
SD_CLEAR_
MONITOR_
WINDOW[7:0]
BIT [7:0] - SD_CLEAR_MONITOR_INTERVAL - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD Clear Monitor Interval - Byte
2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade)
defect clearance
.When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should clear the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Clearance Monitoring period. If, during this SD Defect Clearance Monitoring period, the Receive
STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive
STS-1/STS-3 Transport SD Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear
the SD defect condition
NOTES:
1. The value that the user writes into these three (3) SD Clear Monitor Window Registers, specifies the
duration of the SD Defect Clearance Monitoring Period, in terms of ms.
2. This particular register byte contains the LSB (least significant byte) value of the three registers that
specify the SD Defect Clearance Monitoring period.
TABLE 123: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS
LOCATION= 0X025D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_CLEAR_MONITOR_WINDOW[23:16]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_CLEAR_MONITOR_INTERVAL - MSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF Clear Monitor Interval - Byte
1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure)
defect clearance.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should clear the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the user-
100
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
specified SF Defect Clearance Monitoring period. If, during this SF Defect Clearance Monitoring period, the Receive
STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive
STS-1/STS-3 Transport SF Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor blolck will clear
the SF defect condition.
NOTES:
1. The value that the user writes into these three (3) SF Clear Monitor Window Registers, specifies the
duration of the SF Defect Clearance Monitoring Period, in terms of ms.
2. This particular register byte contains the MSB (Most significant byte) value of the three registers that
specify the SF Defect Clearance Monitoring period.
TABLE 124: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS
LOCATION= 0X025E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_CLEAR_MONITOR_WINDOW[15:8]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_CLEAR_MONITOR_INTERVAL - Bits 15 through 8
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF Clear Monitor Interval - Byte
2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure)
defect clearance.
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should clear the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Clearance Monitoring period. If, during this SF Defect Clearance Monitoring period, the Receive
STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive
STS-1/STS-3 Transport SF Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the
SF defect condition.
NOTE: The value that the user writes into these three (3) SF Clear Monitor Window Registers, specifies the duration of
the SF Defect Clearance Monitoring Period, in terms of ms.
TABLE 125: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS
LOCATION= 0X025F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
SF_CLEAR_MONITOR_WINDOW[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - SF_CLEAR_MONITOR_INTERVAL - LSB
These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF Clear Monitor Interval - Byte
2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure)
defect clearance
When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to
determine if it should clear the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Clearance Monitoring period. If, during this SF Defect Clearance Monitoring period, the Receive
STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive
STS-1/STS-3 Transport SF Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the
SF defect condition.
NOTES:
1. The value that the user writes into these three (3) SF Clear Monitor Window Registers, specifies the
duration of the SF Defect Clearance Monitoring Period, in terms of ms.
101
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
2. This particular register byte contains the LSB (Least Significant byte) value of the three registers that
specify the SF Defect Clearance Monitoring period.
TABLE 126: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X0263)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit
AIS-P
(Downstream) upon
Section
Trace Message Unstable
Transmit
AIS-P
(Downstream)
Upon Section Trace
Message
Mismatch
Transmit
AIS-P
(Downstream) upon
SF
Transmit
AIS-P
(Downstream) upon
SD
Unused
Transmit
AIS-P
(Downstream) upon
LOF
Transmit
AIS-P
(Downstream) upon
LOS
Transmit
AIS-P
(Downstream)
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Transmit Path AIS upon Declaration of the Section Trace Message Unstable Defect Condition
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically
transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH
Processor block), anytime it declares the Section Trace Message Unstable defect condition within the incoming STS-1
or STS-3 data-stream.
` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator
(via the downstream traffic) whenever (and for the duration that) it declares the Section Trace Message Unstable defect
condition.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever (and for the duration that) it declares the Section Trace Message Unstable defect
condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH
Processor block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 6 - Transmit Path AIS (AIS-P) upon Declaration of the Section Trace Message Mismatch Defect Condition
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically
transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH
Processor blocks), anytime (and for the duration that) it declares the Section Trace Message Mismatch defect condition
within the incoming STS-1/STS-3 data stream.
` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator
(via the downstream traffic) whenever it declares the Section Trace Mismatch defect condition.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever (and for the duration that) it declares the Section Trace Message Mismatch defect
condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH
Processor block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 5 - Transmit Path AIS upon declaration of the Signal Failure (SF) defect condition
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically
transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH
Processor block), anytime (and for the duration that) it declares the SF defect condition.
` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the
downstream traffic) upon declaration of the SF defect.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) anytime (and for the duration that) it declares the SF defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH
Processor block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 4 - Transmit Path AIS upon declaration of the Signal Degrade (SD) defect
102
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically
transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH
Processor block) anytime (and for the duration that) it declares the SD defect condition.
` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the
downstream traffic) upon declaration of the SD defect.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) anytime (and for the duration that) it declares the SD defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH
Processor block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 3 - Unused
BIT 2 - Transmit Path AIS upon declaration of the Loss of Frame (LOF) defect
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically
transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH
Processor block), anytime (and for the duration that) it declares the LOF defect condition.
` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the
downstream traffic) upon declaration of the LOF defect.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) anytime (and for the duration that) it declares the LOF defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH
Processor block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 1 - Transmit Path AIS upon declaration of the Loss of Signal (LOS) defect
This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically
transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH
Processor block), anytime (and for the duration that) it declares the LOS defect condition.
` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the
downstream traffic) anytime it declares the LOS defect condition.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) anytime (and for the duration that) it declares the LOS defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH
Processor block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 0 - Automatic Transmission of AIS-P Enable
This READ/WRITE bit-field serves two purposes.
It is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the Path AIS (AIS-P)
indicator, via the down-stream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block), upon detection of
an SF, SD, Section Trace Mismatch, Section Trace Unstable, LOF or LOS defect conditions.
It also is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit a Path AIS (AISP) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block) anytime it
declares the AIS-L defect condition within the incoming STS-1/STS-3 datastream.
` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to NOT automatically transmit the AIS-P indicator (via
the downstream traffic) upon declaration of the AIS-L defect condition or any of the above-mentioned defect conditions.
` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) upon declaration of the AIS-L defect or any of the above-mentioned defect conditions.
NOTE: The user must also set the corresponding bit-fields (within this register) to 1 in order to configure the Receive
STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator upon declaration of a given
alarm/defect condition.
103
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 127: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS (IN DOWNSTREAM T1/E1S) CONTROL REGISTER
(ADDRESS LOCATION= 0X026B)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit AIS
(via Downstream
T1/E1s)
upon LOS
Transmit AIS
(via Downstream
T1/E1s)
upon LOF
Transmit AIS
(via Downstream
T1/E1s)
upon SD
Transmit AIS
(via Downstream
T1/E1s)
upon SF
Unused
Transmit AIS
(via Downstream
T1/E1s)
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/O
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Unused
BIT 5 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the LOS (Loss of Signal) defect
condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that)
the Receive STS-1/STS-3 TOH Processor block declares the LOS defect condition.3
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1/STS-3 TOH Processor block
declares the LOS defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH
Processor block declares the LOS defect condition.
BIT 4 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the LOF (Loss of Frame) defect
condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that)
the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1/STS-3 TOH Processor block
declares the LOF defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH
Processor block declares the LOF defect condition.
BIT 3 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the SD (Signal Degrade) defect condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that)
the Receive STS-1/STS-3 TOH Processor block declares the SD defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1/STS-3 TOH Processor block
declares the SD defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH
Processor block declares the SD defect condition.
BIT 2 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the Signal Failure (SF) defect condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that)
the Receive STS-1/STS-3 TOH Processor block declares the SF defect condition.
` 0 - Does not configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1/STS-3 TOH Processor block
declares the SF defect condition.
104
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH
Processor block declares the SF defect condition.
BIT 1 - Unused
BIT 0 - Automatic Transmission of DS1/E1 AIS (via the downstream DS1/E1s) Enable
This READ/WRITE bit-field serves two purposes.It is used to configure each of the 28 Egress Direction Transmit
DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, upon
declaration of either the SF, SD, LOS or LOF defect conditions via the Receive STS-1/STS-3 TOH Processor block.
It also is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit
the DS1/E1 AIS indicator, via its outbound DS1/E1 signals, upon declaration of the AIS-L defect condition, via the
Receive STS-1/STS-3 TOH Processor block.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS indicator, whenever the Receive STS-1/STS-3 TOH Processor block declares either the LOS, LOF, SD,
SF or AIS-L defect conditions.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS indicator, whenever (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares either the
LOS, LOF, SD, SF or AIS-L defect conditions.
TABLE 128: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS
LOCATION= 0X026E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive A1, A2 Byte Error Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive A1, A2 Byte Error Count Register - MSB Register
This RESET-upon-READ register, along with the Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register
- Byte
0 presents a 16-bit representation of the total number of A1 and A2 byte errors that the Receive STS-1/STS-3 TOH
Processor block has detected (within the incoming STS-1/STS-3 data-stream) since the last read of this register.
NOTE: This register contains the MSB (Most Significant Byte) of this 16-bit expression.
TABLE 129: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS
LOCATION= 0X026F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive A1, A2 Byte Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive A1, A2 Byte Error Count Register - LSB Register
This RESET-upon-READ register, along with the Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register
- Byte 1 presents a 16-bit representation of the total number of A1 and A2 byte errors that the Receive STS-1/STS-3
TOH Processor block has detected (within the incoming STS-1/STS-3 data-stream) since the last read of this register.
NOTE: This register contains the LSB (Least Significant Byte) of this 16-bit expression.
2.4
RECEIVE STS-1 POH PROCESSOR BLOCK REGISTERS
The register map for the Receive STS-1 POH Processor Block is presented in the Table below. Additionally, a
detailed description of each of the Receive STS-1/STS-3 POH Processor block registers is presented below.
105
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328, with the Receive STS-1 POH Processor block highlighted is presented below in Figure 4.
FIGURE 4. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS-1
POH PROCESSOR BLOCK HIGHLIGHTED
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
TABLE 130: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0281)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Payload_Type[1:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:2] - Unused
BIT [1:0] - Payload_Type[1:0]
106
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 131: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0283)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
CheckStuff
RDI-PType
REI-PError
Type
B3 Error
Type
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT 3 - Check (Pointer Adjustment) Stuff Select
This READ/WRITE bit-field is used to enable/disable the SONET standard recommendation that a pointer increment or
decrement operation, detected within 3 SONET frames of a previous pointer adjustment operation (e.g., negative stuff,
positive stuff) is ignored.
` 0 - Disables this SONET standard implementation. In this mode, all pointer-adjustment operations that are detected
will be accepted.
` 1 - Enables this SONET standard implementation. In this mode, all pointer-adjustment operations that are detected
within 3 SONET frame periods of a previous pointer-adjustment operation will be ignored.
BIT 2 - Path - Remote Defect Indicator Type Select
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to support either the SingleBit or the Enhanced RDI-P form of signaling, as described below.
` 0 - Configures the Receive STS-1 POH Processor block to support Single-Bit RDI-P.
In this mode, the Receive STS-1 POH Processor block will only monitor BIT 5, within the G1 byte (of the incoming SPE
data), in order to declare and clear the RDI-P defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to support Enhanced RDI-P (ERDI-P).
In this mode, the Receive STS-1 POH Processor block will monitor bits 5, 6 and 7, within the G1 byte, in order to declare
and clear the RDI-P defect condition.
BIT 1 - REI-P Error Type
This READ/WRITE bit-field is used to specify how the Receive STS-1 POH Processor block will count (or tally) REI-P
events, for Performance Monitoring purposes. The user can configure the Receive STS-1 POH Processor block to
increment REI-P events on either a per-bit or per-frame basis.
If the user configures the Receive STS-1 POH Processor block to increment REI-P events on a per-bit basis, then it
will increment the Receive Path REI-P Error Count register by the value of the lower nibble within the G1 byte of the
incoming STS-1/STS-3 data-stream.
If the user configures the Receive STS-1 POH Processor block to increment REI-P events on a per-frame basis, then
it will increment the Receive Path REI-P Error Count register each time it receives an STS-1/STS-3 frame, in which the
lower nibble of the G1 byte (bits 1 through 4) are set to a non-zero value.
` 0 - Configures the Receive STS-1 POH Processor block to count or tally REI-P events on a per-bit basis.
` 1 - Configures the Receive STS-1 POH Processor block to count or tally REI-P events on a per-frame basis.
BIT 0 - B3 Error Type
This READ/WRITE bit-field is used to specify how the Receive STS-1 POH Processor block will count (or tally) B3 byte
errors, for Performance Monitoring purposes. The user can configure the Receive STS-1 POH Processor block to
increment B3 byte errors on either a per-bit or per-frame basis.
If the user configures the Receive STS-1 POH Processor block to increment B3 byte errors on a per-bit basis, then it
will increment the Receive Path B3 Byte Error Count register by the number of bits (within the B3 byte value) that is in
error.
If the user configures the Receive STS-1 POH Processor block to increment B3 byte errors on a per-frame basis, then
it will increment the Receive Path B3 Byte Error Count register each time it receives an STS-1/STS-3 frame that contains
an erred B3 byte.
` 0 - Configures the Receive STS-1 POH Processor block to count B3 byte errors on a per-bit basis
` 1 - Configures the Receive STS-1 POH Processor block to count B3 byte errors on a per-frame basis.
107
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 132: RECEIVE STS-1 PATH - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0286)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
BIT 0
Path Trace
Message
Unstable
Defect
Declared
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:1] - Unused
BIT 0 - Path Trace Message Unstable Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
Path Trace Message Unstable defect condition. The Receive STS-1 POH Processor block will declare the Path Trace
Message Unstable defect condition, whenever the Path Trace Message Unstable counter reaches the value 8. The
Path Trace Message Unstable counter will be incremented for each time that it receives a Path Trace message that
differs from the previously received message. The Path Trace Unstable counter is cleared to 0 whenever the Receive
STS-1 POH Processor block has received a given Path Trace Message 3 (or 5) consecutive times.
NOTE: Receiving a given Path Trace Message 3 (or 5) consecutive times also sets this bit-field to 0
` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the Path Trace Message
Unstable defect.
` 1 - Indicates that the Receive STS-1 POH Processor blolck is currently declaring the Path Trace Message Unstable
defect condition.
TABLE 133: RECEIVE STS-1 PATH - SONET RECEIVE POH STATUS - BYTE 0 (ADDRESS LOCATION= 0X0287)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TIM-P Defect
Declared
C2 Byte
UnstableDefect Declared
UNEQ-PDefectDeclared
PLM-PDefectDeclared
RDI-PDefectDeclared
RDI-P
UnstableCondition
LOP-PDefectDeclared
AIS-PDefectDeclared
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - Trace Identification Mismatch (TIM-P) Defect Indicator
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
Path Trace Identification Mismatch (TIM-P) defect condition. The Receive STS-1 POH Processor block will declare the
TIM-P defect condition, when none of the received 64-byte string (received via the J1 byte, within the incoming STS1/STS-3 data-stream) matches the expected 64 byte message.The Receive STS-1 POH Processor block will clear the
TIM-P defect condition, when 80% of the received 64 byte string (received via the J1 byte) matches the expected 64
byte message.
` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the TIM-P defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the TIM-P defect condition.
BIT 6 - C2 Byte (Path Signal Label Byte) Unstable Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
Path Signal Label Byte Unstable defect condition. The Receive STS-1 POH Processor block will declare the C2 (Path
Signal Label Byte) Unstable defect condition, whenever the C2 Byte Unstable counter reaches the value 5. The C2
Byte Unstable counter will be incremented for each time that it receives an SPE with a C2 byte value that differs from
the previously received C2 byte value. The C2 Byte Unstable counter is cleared to 0 whenever the Receive STS-1
POH Processor block has received 3 (or 5) consecutive SPEs that each contains the same C2 byte
108
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
value.Note:Receiving a given C2 byte value in 3 (or 5) consecutive SPEs also sets this bit-field to 0.
` 0 - Indicates that the Receive STS-1 POH Processor block is currently NOT declaring the C2 (Path Signal Label Byte)
Unstable defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the C2 (Path Signal Label Byte)
Unstable defect condition.
BIT 5 - Path - Unequipped (UNEQ-P) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
UNEQ-P defect condition. The Receive STS-1 POH Processor block will declare the UNEQ-P defect condition, anytime
that it receives at least five (5) consecutive STS-1/STS-3 frames, in which the C2 byte was set to the value 0x00 (which
indicates that the SPE is Unequipped).
The Receive STS-1 POH Processor block will clear the UNEQ-P defect condition, if it receives at least five (5)
consecutive STS-1/STS-3 frames, in which the C2 byte was set to a value other than 0x00.
` 0 - Indicates that the Receive STS-1 POH Processor block is currently NOT declaring the UNEQ-P defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the UNEQ-P defect condition.
NOTE: :The Receive STS-1 POH Processor block will not declare the UNEQ-P defect condition if it configured to
expect to receive STS-1/STS-3 frames with C2 bytes being set to 0x00 (e.g., if the Receive STS-1 Path Expected Path Label Value Register -Address Location= 0x0297) is set to 0x00.
BIT 4 - Path Payload Mismatch (PLM-P) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
PLM-P defect condition.The Receive STS-1 POH Processor block will declare the PLM-P defect condition, if it receives
at least five (5) consecutive STS-1/STS-3 frames, in which the C2 byte was set to a value other than that which it is
expecting to receive. Whenever the Receive STS-1 POH Processor block is determining whether or not it should
declare the PLM-P defect, it will check the contents of the following two registers.
•
The Receive STS-1 Path - Received Path Label Value Register (Address Location= 0xN196).
•
The Receive STS-1 Path - Expected Path Label Value Register (Address Location= 0xN197).
The Receive STS-1 Path - Expected Path Label Value Register contains the value of the C2 bytes, that the Receive
STS-1 POH Processor blocks expects to receive.The Receive STS-1 Path - Received Path Label Value Register
contains the value of the C2 byte, that the Receive STS-1 POH Processor block has most received validated (by
receiving this same C2 byte in five consecutive STS-1/STS-3 frames). The Receive STS-1 POH Processor block will
declare the PLM-P defect condition if the contents of these two register do not match. The Receive STS-1 POH
Processor block will clear the PLM-P defect condition if whenever the contents of these two registers do match.
` 0 - Indicates that the Receive STS-1 POH Processor block is currently NOT declaring the PLM-P defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the PLM-P defect condition
NOTE: The Receive STS-1 POH Processor block will clear the PLM-P defect, upon declaring the UNEQ-P defect
condition.
BIT 3 - Path Remote Defect Indicator (RDI-P) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
RDI-P defect condition.
If the Receive STS-1 POH Processor block is configured to support the Single-bit RDI-P function, then it will declare
the RDI-P defect condition if BIT 5 (within the G1 byte of the incoming STS-1/STS-3 frame) is set to 1 for RDI-P_THRD
number of incoming consecutive STS-1/STS-3 frames.
If the Receive STS-1 POH Processor block is configured to support the Enhanced RDI-P (ERDI-P) function, then it will
declare the RDI-P defect condition if Bits 5, 6 and 7 (within the G1 byte of the incoming STS-1/STS-3 frame) are set to
[0, 1, 0], [1, 0, 1] or [1, 1, 0] for RDI-P_THRD number of consecutive STS-1/STS-3 frames.
` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the RDI-P defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the RDI-P defect condition.
NOTE: The user can specify the value for RDI-P_THRD by writing the appropriate data into Bits 3 through 0 (RDI-P
THRD) within the Receive STS-1 Path - SONET Receive RDI-P Register (Address Location= 0x0293).
BIT 2 - RDI-P (Path - Remote Defect Indicator) Unstable Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
RDI-P Unstable defect condition. The Receive STS-1 POH Processor block will declare a RDI-P I Unstable defect
109
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
condition whenever the RDI-P Unstable Counter reaches the value RDI-P THRD. The RDI-P Unstable counter is
incremented for each time that the Receive STS-1 POH Processor block receives an RDI-P value that differs from that
of the previous STS-1/STS-3 frame. The RDI-P Unstable counter is cleared to 0 whenever the same RDI-P value is
received in RDI-P_THRD consecutive STS-1/STS-3 frames.
NOTE: Receiving a given RDI-P value, in RDI-P_THRD consecutive STS-1/STS-3 frames also clears this bit-field to 0.
` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the RDI-P Unstable defect
condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the RDI-P Unstable defect condition.
NOTE: The user can specify the value for RDI-P_THRD by writing the appropriate data into Bits 3 through 0 (RDI-P
THRD) within the Receive STS-1 Path - SONET Receive RDI-P Register (Address Location= 0x0293).
BIT 1 - Loss of Pointer Indicator (LOP-P) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
LOP-P (Loss of Pointer) defect condition.
The Receive STS-1 POH Processor block will declare the LOP-P defect condition, if it cannot detect a valid pointer (H1
and H2 bytes, within the TOH) within 8 to 10 consecutive SONET frames. Further, the Receive STS-1 POH Processor
block will declare the LOP-P defect condition, if it detects 8 to 10 consecutive NDF events. The Receive STS-1 POH
Processor block will clear the LOP-P defect condition, whenever it detects valid pointer bytes (e.g., the H1 and H2 bytes,
within the TOH) and normal NDF value for three consecutive incoming STS-1/STS-3 frames.
` 0 - Indicates that the Receive STS-1 POH Processor block is NOT declaring the LOP-P defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the LOP-P defect condition.
BIT 0 - Path AIS (AIS-P) Defect Declared
This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the
AIS-P defect condition. The Receive STS-1 POH Processor block will declare the AIS-P defect condition if it detects
all of the following conditions within three consecutive incoming STS-1/STS-3 frames.·
•
The H1, H2 and H3 bytes are set to an All Ones pattern.·
•
The entire SPE is set to an All Ones pattern.
The Receive STS-1 POH Processor block will clear the AIS-P defect condition when it detects a valid STS-1/STS-3
pointer (H1 and H2 bytes) and a set or normal NDF for three consecutive STS-1/STS-3 frames.
` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the AIS-P defect condition.
` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the AIS-P defect condition
NOTE: The Receive STS-1 POH Processor block will NOT declare the LOP-P defect condition if it detects an All Ones
pattern in the H1, H2 and H3 bytes. It will, instead, declare the AIS-P defect condition.
TABLE 134: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 2 (ADDRESS LOCATION=
0X0289)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Detection of
AIS Pointer
Interrupt
Status
Detection of
Pointer
Change
Interrupt
Status
Unused
Change in
TIM-P Defect
Condition
Interrupt
Status
Change in Path
Trace Message
Unstable Defect
Condition
Interrupt Status
R/O
R/O
R/O
RUR
RUR
R/O
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:5] - Unused
BIT 4 - Detection of AIS Pointer Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of AIS Pointer interrupt has occurred since the
last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate this
interrupt anytime it detects an AIS Pointer in the incoming STS-1/STS-3 data stream.
110
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: An AIS Pointer is defined as a condition in which both the H1 and H2 bytes (within the TOH) are each set to an
All Ones pattern.
` 0 - Indicates that the Detection of AIS Pointer interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of AIS Pointer interrupt has occurred since the last read of this register.
BIT 3 - Detection of Pointer Change Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of Pointer Change Interrupt has occurred since
the last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an
interrupt anytime it accepts a new pointer value (e.g., H1 and H2 bytes, in the TOH bytes).
` 0 - Indicates that the Detection of Pointer Change Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of Pointer Change Interrupt has occurred since the last read of this register.
BIT 2 - Unused
BIT 1 - Change in TIM-P (Trace Identification Mismatch) Defect Condition Interrupt
This RESET-upon-READ bit-field indicates whether or not the Change in TIM-P Defect Condition interrupt has occurred
since the last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate
an interrupt in response to either of the following events.
•
Whenever the Receive STS-1 POH Processor block declares the TIM-P defect condition.
•
Whenever the Receive STS-1 POH Processor block clears the TIM-P defect condition.
` 0 - Indicates that the Change in TIM-P Defect Condition Interrupt has not occurred since the last read of this register.
` 1 - Indicates that the Change in TIM-P Defect Condition Interrupt has occurred since the last read of this register.
BIT 0 - Change in Path Trace Identification Message Unstable Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in Path Trace Message Unstable Defect
Condition Interrupt has occurred since the last read of this register.If this interrupt is enabled, then the Receive STS-1
POH Processor block will generate this interrupt in response to either of the following events.
•
Whenever the Receive STS-1 POH Processor block declare the Path Trace Message Unstable Defect
Condition.
•
Whenever the Receive
condition.
STS-1 POH Processor block clears the Path Trace Message Unstable defect
` 0 - Indicates that the Change in Path Trace Message Unstable Defect Condition Interrupt has NOT occurred since
the last read of this register.
` 1 - Indicates that the Change in Path Trace Message Unstable Defect Condition Interrupt has occurred since the last
read of this register.
TABLE 135: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 1 (ADDRESS LOCATION=
0X028A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
New Path
Trace
Message
Interrupt
Status
Detection of
REI-P Event
Interrupt
Status
Change in
UNEQ-P
Defect
Condition
Interrupt
Status
Change in
PLM-P
Defect
Condition
Interrupt
Status
New
C2 Byte
Interrupt
Status
Change in
C2 Byte
Unstable
Defect
Condition
Interrupt
Status
Change in
RDI-P
Unstable
Defect
Condition
Interrupt
Status
New RDI-P
Value
Interrupt
Status
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - New Path Trace Message Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the New Path Trace Message Interrupt has occurred since
the last read of this register.
111
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has
accepted (or validated) a new Path Trace Message.
` 0 - Indicates that the New Path Trace Message Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the New Path Trace Message Interrupt has occurred since the last read of this register.
BIT 6 - Detection of REI-P Event Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of REI-P Event Interrupt has occurred since
the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
an REI-P event within the incoming STS-1/STS-3 data-stream.
` 0 - Indicates that the Detection of REI-P Event Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of REI-P Event Interrupt has occurred since the last read of this register.
BIT 5 - Change in UNEQ-P (Path - Unequipped) Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in UNEQ-P Defect Condition interrupt has
occurred since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following conditions.
•
When the Receive STS-1 POH Processor block declares the UNEQ-P Defect Condition.
•
When the Receive STS-1 POH Processor block clears the UNEQ-P Defect Condition.
` 0 - Indicates that the Change in UNEQ-P Defect Condition Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the Change in UNEQ-P Defect Condition Interrupt has occurred since the last read of this register.
NOTE: The user can determine if the Receive STS-1 POH Processor block is currently declaring the UNEQ-P defect
condition by reading out the state of BIT 5 (UNEQ-P Defect Declared) within the Receive STS-1 Path - SONET
Receive POH Status - Byte 0 Register (Address Location= 0xN187).
BIT 4 - Change in PLM-P (Path - Payload Mismatch) Defect Condition Interrupt Status
This RESET-upon-READ bit indicates whether or not the Change in PLM-P Defect Condition interrupt has occurred
since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following conditions.
•
When the Receive STS-1 POH Processor block declares the PLM-P Defect Condition.
•
When the Receive STS-1 POH Processor block clears the PLM-P Defect Condition.
` 0 - Indicates that the Change in PLM-P Defect Condition Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the Change in PLM-P Defect Condition Interrupt has occurred since the last read of this register.
BIT 3 - New C2 Byte Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the New C2 Byte Interrupt has occurred since the last read
of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has
accepted a new C2 byte.
` 0 - Indicates that the New C2 Byte Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the New C2 Byte Interrupt has occurred since the last read of this register.
BIT 2 - Change in C2 Byte Unstable Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in C2 Byte Unstable Defect Condition Interrupt
has occurred since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
When the Receive STS-1 POH Processor block declares the C2 Byte Unstable defect condition.
•
When the Receive STS-1 POH Processor block clears the C2 Byte Unstable defect condition.
112
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 0 - Indicates that the Change in C2 Byte Unstable Defect Condition Interrupt has NOT occurred since the last read of
this register.
` 1 - Indicates that the Change in C2 Byte Unstable Defect Condition Interrupt has occurred since the last read of this
register.
NOTE: The user can determine whether or not the Receive STS-1 POH Processor block is currently declaring the C2
Byte Unstable Defect Condition by reading out the state of BIT6 (C2 Byte Unstable Defect Declared) within the
Receive STS-1 Path - SONET Receive POH Status - Byte 0 Register (Address Location= 0x0287).
BIT 1 - Change in RDI-P Unstable Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in RDI-P Unstable Defect Condition interrupt has
occurred since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following conditions.
•
When the Receive STS-1 POH Processor block declares an RDI-P Unstable defect condition.
•
When the Receive STS-1 POH Processor block clears the RDI-P Unstable defect condition.
` 0 - Indicates that the Change in RDI-P Unstable Defect Condition Interrupt has NOT occurred since the last read of
this register.
` 1 - Indicates that the Change in RDI-P Unstable Defect Condition Interrupt has occurred since the last read of this
register.
NOTE: The user can determine the current state of RDI-P Unstable Defect condition by reading out the state of BIT 2
(RDI-P Unstable Defect Condition) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0
Register (Address Location= 0x0287).
BIT 0 - New RDI-P Value Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the New RDI-P Value interrupt has occurred since the last
read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate this interrupt anytime it receives
and validates a new RDI-P value.
` 0 - Indicates that the New RDI-P Value Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the New RDI-P Value Interrupt has occurred since the last read of this register.
NOTE: The user can obtain the New RDI-P Value by reading out the contents of the RDI-P ACCEPT[2:0] bit-fields.
These bit-fields are located in Bits 6 through 4, within the Receive STS-1 Path - SONET Receive RDI-P
Register (Address Location= 0x0293).
TABLE 136: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 0 (ADDRESS LOCATION=
0X028B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Detection of
B3 Byte
Error
Interrupt
Status
Detection of
New Pointer
Interrupt
Status
Detection of
Unknown
Pointer
Interrupt
Status
Detection of
Pointer Decrement
Interrupt
Status
Detection of
Pointer
Increment
Interrupt
Status
Detection of
NDF Pointer
Interrupt
Status
Change of
LOP-P
Defect
Condition
Interrupt
Status
Change of
AIS-P Defect
Condition
Interrupt
Status
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - Detection of B3 Byte Error Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of B3 Byte Error Interrupt has occurred since
the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
a B3 byte error in the incoming STS-1/STS-3 data stream.
` 0 - Indicates that the Detection of B3 Byte Error Interrupt has NOT occurred since the last read of this interrupt.
113
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 1 - Indicates that the Detection of B3 Byte Error Interrupt has occurred since the last read of this interrupt.
BIT 6 - Detection of New Pointer Interrupt Status
This RESET-upon-READ indicates whether the Detection of New Pointer interrupt has occurred since the last read of
this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
a new pointer value in the incoming STS-1/STS-3 frame.
NOTE: Pointer Adjustments with NDF will not generate this interrupt.
` 0 - Indicates that the Detection of New Pointer Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of New Pointer Interrupt has occurred since the last read of this register.
BIT 5 - Detection of Unknown Pointer Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of Unknown Pointer interrupt has occurred
since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime that it
detects a pointer that does not fit into any of the following categories.
•
An Increment Pointer
•
A Decrement Pointer
•
An NDF Pointer
•
An AIS (e.g., All Ones) Pointer
•
New Pointer
` 0 - Indicates that the Detection of Unknown Pointer interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of Unknown Pointer interrupt has occurred since the last read of this register.
BIT 4 - Detection of Pointer Decrement Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of Pointer Decrement Interrupt has occurred
since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
a Pointer Decrement event.
` 0 - Indicates that the Detection of Pointer Decrement interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of Pointer Decrement interrupt has occurred since the last read of this register.
BIT 3 - Detection of Pointer Increment Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of Pointer Increment Interrupt has occurred
since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will
generate an interrupt anytime it detects a Pointer Increment event.
` 0 - Indicates that the Detection of Pointer Increment interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of Pointer Increment interrupt has occurred since the last read of this register.
BIT 2 - Detection of NDF Pointer Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Detection of NDF Pointer interrupt has occurred since
the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
an NDF Pointer event.
` 0 - Indicates that the Detection of NDF Pointer interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of NDF Pointer interrupt has occurred since the last read of this register.
BIT 1 - Change of LOP-P Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change in LOP-P Defect Condition interrupt has occurred
since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
When the Receive STS-1 POH Processor block declares the LOP-P defect condition.
114
PRELIMINARY
REV. P1.0.6
•
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
·When the Receive STS-1 POH Processor block clears the LOP-P defect condition.
` 0 - Indicates that the Change in LOP-P Defect Condition interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the Change in LOP-P Defect Condition interrupt has occurred since the last read of this register.
NOTE: The user can determine if the Receive STS-1 POH Processor block is currently declaring the LOP-P defect
condition by reading out the state of BIT 1 (LOP-P Defect Declared) within the Receive STS-1 Path - SONET
Receive POH Status - Byte 0 Register (Address Location=0x0287).
BIT 0 - Change of AIS-P Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Change of AIS-P Defect Condition Interrupt has occurred
since the last read of this register.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
Whenever the Receive STS-1 POH Processor block declares the AIS-P defect condition.
•
Whenever the Receive STS-1 POH Processor block clears the AIS-P defect condition.
` 0 - Indicates that the Change of AIS-P Defect Condition Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of AIS-P Defect Condition Interrupt has occurred since the last read of this register.
NOTE: The user can determine if the Receive STS-1 POH Processor block is currently declaring the AIS-P defect
condition by reading out the state of BIT 0 (AIS-P Defect Declared) within the Receive STS-1 Path - SONET
Receive POH Status - Byte 0 Register (Address Location= 0x0287).
TABLE 137: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 2 (ADDRESS LOCATION =
0X028D)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Detection of
AIS Pointer
Interrupt
Enable
Detection of
Pointer
Change
Interrupt
Enable
Unused
Change in
TIM-P Defect
Condition
Interrupt
Enable
Change in
Path Trace
Message
Unstable
Defect
Condition
Interrupt
Enable
R/O
R/O
R/O
R/W
R/W
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:5] - Unused
BIT 4 - Detection of AIS Pointer Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of AIS Pointer interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
an AIS Pointer, in the incoming STS-1/STS-3 data stream.
NOTE: An AIS Pointer is defined as a condition in which both the H1 and H2 bytes (within the TOH) are each set to an
All Ones Pattern.
` 0 - Disables the Detection of AIS Pointer Interrupt.
` 1 - Enables the Detection of AIS Pointer Interrupt.
BIT 3 - Detection of Pointer Change Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of Pointer Change Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has
accepted a new pointer value.
` 0 - Disables the Detection of Pointer Change Interrupt.
` 1 - Enables the Detection of Pointer Change Interrupt.
115
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT 2 - Unused
BIT 1 - Change in TIM-P (Trace Identification Mismatch) Defect Condition Interrupt
This READ/WRITE bit-field is used to either enable or disable the Change in TIM-P Condition interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
If the TIM-P defect condition is declared.
•
If the TIM-P defect condition is cleared.
` 0 - Disables the Change in TIM-P Defect Condition Interrupt.
` 1 - Enables the Change in TIM-P Defect Condition Interrupt.
BIT 0 - Change in Path Trace Message Unstable Defect Condition Interrupt Status
This READ/WRITE bit-field is used to either enable or disable the Change in Path Trace Message Unstable Defect
Condition Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
Whenever the Receive STS-1 POH Processor block declares the Path Trace Message Unstable Defect
Condition.· Whenever the Receive STS-1 POH Processor block clears the Path Trace Message Unstable
Defect Condition.
` 0 - Disables the Change in Path Trace Message Unstable Defect Condition interrupt.
` 1 - Enables the Change in Path Trace Message Unstable Defect Condition interrupt.
TABLE 138: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 1 (ADDRESS LOCATION=
0X028E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
New Path
Trace Message Interrupt Enable
Detection of
REI-P Event
Interrupt
Enable
Change in
UNEQ-P
Defect Condition Interrupt Enable
Change in
PLM-P
Defect Condition Interrupt Enable
New C2 Byte
Interrupt
Enable
Change in
C2 Byte
Unstable
Defect Condition Interrupt Enable
Change in
RDI-P
Unstable
Defect Condition Interrupt Enable
New RDIPValue Interrupt Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - New Path Trace Message Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the New Path Trace Message Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has
accepted (or validated) and new Path Trace Message.
` 0 - Disables the New Path Trace Message Interrupt.
` 1 - Enables the New Path Trace Message Interrupt.
BIT 6 - Detection of REI-P Event Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of REI-P Event Interrupt.
If this interrupt is enabled, then he Receive STS-1 POH Processor block will generate an interrupt anytime it detects
an REI-P condition in the coming STS-1/STS-3 data-stream.
` 0 - Disables the Detection of REI-P Event Interrupt.
` 1 - Enables the Detection of REI-P Event Interrupt.
BIT 5 - Change in UNEQ-P (Path - Unequipped) Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change in UNEQ-P Defect Condition interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following conditions
116
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
•
When the Receive STS-1 POH Processor block declares the UNEQ-P Defect Condition.
•
When the Receive STS-1 POH Processor block clears the UNEQ-P Defect Condition.
` 0 - Disables the Change in UNEQ-P Defect Condition Interrupt.
` 1 - Enables the Change in UNEQ-P Defect Condition Interrupt.
BIT 4 - Change in PLM-P (Path - Payload Label Mismatch) Defect Condition Interrupt Enable
This READ/WRITE bit is used to either enable or disable the Change in PLM-P Defect Condition interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following conditions.
•
Whenever the Receive STS-1 POH Processor block declares the PLM-P defect Condition.
•
Whenever the Receive STS-1 POH Processor block clears the PLM-P defect Condition.
` 0 - Disables the Change in PLM-P Defect Condition Interrupt.
` 1 - Enables the Change in PLM-P Defect Condition Interrupt.
BIT 3 - New C2 Byte Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the New C2 Byte Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has
accepted a new C2 byte.
` 0 - Disables the New C2 Byte Interrupt.
` 1 - Enables the New C2 Byte Interrupt.
NOTE: The user can obtain the value of this New C2 byte by reading the contents of the Receive STS-1 Path Received Path Label Value Register (Address Location= 0x0296).
BIT 2 - Change in C2 Byte Unstable Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change in C2 Byte Unstable Condition Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
When the Receive STS-1 POH Processor block declares the C2 Byte Unstable defect condition.
•
When the Receive STS-1 POH Processor block clears the C2 Byte Unstable defect condition.
` 0 - Disables the Change in C2 Byte Unstable Defect Condition Interrupt.
` 1 - Enables the Change in C2 Byte Unstable Defect Condition Interrupt.
BIT 1 - Change in RDI-P Unstable Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change in RDI-P Unstable Defect Condition interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following conditions.
•
Whenever the Receive STS-1 POH Processor block declares the RDI-P Unstable defect condition.
•
Whenever the Receive STS-1 POH Processor block clears the RDI-P Unstable defect condition.
` 0 - Disables the Change in RDI-P Unstable Defect Condition Interrupt.
` 1 - Enables the Change in RDI-P Unstable Defect Condition Interrupt.
BIT 0 - New RDI-P Value Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the New RDI-P Value interrupt.If this interrupt is enabled,
then the Receive STS-1 POH Processor block will generate this interrupt anytime it receives and validates a new RDIP value.
` 0 - Disables the New RDI-P Value Interrupt.
` 1 - Enable the New RDI-P Value Interrupt.
117
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 139: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 0 (ADDRESS LOCATION=
0X028F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Detection of
B3 Byte
ErrorInterruptEnable
Detection of
New Pointer
Interrupt
Enable
Detection of
Unknown
Pointer Interrupt Enable
Detection of
Pointer Decrement Interrupt Enable
Detection of
Pointer
IncrementInterrupt
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Detection of
Change of
Change of
NDF PointerLOP-P
AIS-P
Interrupt
DefectCondi- DefectCondiEnable
tion Interrupt tionInterrupt
Enable
Enable
BIT 7 - Detection of B3 Byte Error Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of B3 Byte Error Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
a B3-byte error in the incoming STS-1/STS-3 data-stream.
` 0 - Disables the Detection of B3 Byte Error interrupt.
` 1 - Enables the Detection of B3 Byte Error interrupt.
BIT 6 - Detection of New Pointer Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of New Pointer interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a
new pointer value in the incoming STS-1/STS-3 frame.
NOTE: :Pointer Adjustments with NDF will not generate this interrupt.
` 0 - Disables the Detection of New Pointer Interrupt.
` 1 - Enables the Detection of New Pointer Interrupt.
BIT 5 - Detection of Unknown Pointer Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of Unknown Pointer interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a
Pointer Adjustment that does not fit into any of the following categories.· An Increment Pointer.· A Decrement Pointer·
An NDF Pointer· AIS Pointer· New Pointer.
` 0 - Disables the Detection of Unknown Pointer Interrupt.
` 1 - Enables the Detection of Unknown Pointer Interrupt.
BIT 4 - Detection of Pointer Decrement Interrupt Enable
This READ/WRITE bit-field is used to enable or disable the Detection of Pointer Decrement Interrupt.
If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt anytime it
detects a Pointer-Decrement event.
` 0 - Disables the Detection of Pointer Decrement Interrupt.
` 1 - Enables the Detection of Pointer Decrement Interrupt.
BIT 3 - Detection of Pointer Increment Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of Pointer Increment Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
a Pointer Increment event.
` 0 - Disables the Detection of Pointer Increment Interrupt.
` 1 - Enables the Detection of Pointer Increment Interrupt.
BIT 2 - Detection of NDF Pointer Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Detection of NDF Pointer Interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects
118
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
an NDF Pointer event.
` 0 - Disables the Detection of NDF Pointer interrupt.
` 1 - Enables the Detection of NDF Pointer interrupt.
BIT 1 - Change of LOP-P Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change in LOP (Loss of Pointer) Condition interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
When the Receive STS-1 POH Processor block declares the LOP-P defect condition condition.
•
When the Receive STS-1 POH Processor block clears the LOP-P defect condition.
` 0 - Disable the Change of LOP-P Defect Condition Interrupt.
` 1 - Enables the Change of LOP-P Defect Condition Interrupt.
NOTE: The user can determine the current state of the LOP-P Defect condition by reading out the contents of BIT 1
(LOP-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 (Address
Location= 0x0287).
BIT 0 - Change of AIS-P Defect Condition Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of AIS-P (Path AIS) Defect Condition
interrupt.
If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either
of the following events.
•
When the Receive STS-1 POH Processor block declares the AIS-P Defect condition.
•
When the Receive STS-1 POH Processor block clears the AIS-P Defect condition.
` 0 - Disables the Change of AIS-P Defect Condition Interrupt.
` 1 - Enables the Change of AIS-P Defect Condition Interrupt.
NOTE: The user can determine the current state of the AIS-P Defect Condition by reading out the contents of BIT 0
(AIS-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 (Address
Location= 0x0287).
TABLE 140: RECEIVE STS-1 PATH - SONET RECEIVE RDI-P REGISTER (ADDRESS LOCATION= 0X0293)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
RDI-P_ACCEPT[2:0]
BIT 2
BIT 1
BIT 0
RDI-P THRESHOLD[3:0]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Unused
BIT [6:4] - Accepted RDI-P Value
These READ-ONLY bit-fields contain the value of the most recently accepted RDI-P (e.g., bits 5, 6 and 7 within the G1
byte) value that has been accepted by the Receive STS-1 POH Processor block.
NOTE: A given RDI-P value will be accepted by the Receive STS-1 POH Processor block, if this RDI-P value has been
consistently received in RDI-P THRESHOLD[3:0] number of STS-1/STS-3 frames.
BIT [3:0] - RDI-P Threshold[3:0]
These READ/WRITE bit-fields are used to defined the RDI-P Acceptance Threshold for the Receive STS-1 POH
Processor Block.
The RDI-P Acceptance Threshold is the number of consecutive STS-1/STS-3 frames, in which the Receive STS-1 POH
Processor block must receive a given RDI-P value, before it accepts or validates it.
The most recently accepted RDI-P value is written into the RDI-P ACCEPT[2:0] bit-fields, within this register.
119
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 141: RECEIVE STS-1 PATH - RECEIVED PATH LABEL VALUE (ADDRESS LOCATION= 0X0296)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Received_C2_Byte_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
1
1
1
1
1
1
1
1
BIT [7:0] - Received Filtered C2 Byte Value
These READ-ONLY bit-fields contain the value of the most recently accepted C2 byte, via the Receive STS-1 POH
Processor block.
The Receive STS-1 POH Processor block will accept a C2 byte value (and load it into these bit-fields) if it has received
a consistent C2 byte, in five (5) consecutive STS-1/STS-3 frames.
NOTE: The Receive STS-1 POH Processor block uses this register, along the Receive STS-1 Path - Expected Path
Label Value Register (Address Location = 0x0297), when declaring or clearing the UNEQ-P and PLM-P defect
conditions.
TABLE 142: RECEIVE STS-1 PATH - EXPECTED PATH LABEL VALUE (ADDRESS LOCATION= 0X0297)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Expected_C2_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT [7:0] - Expected C2 Byte Value
These READ/WRITE bit-fields are used to specify the C2 (Path Label Byte) value, that the Receive STS-1 POH
Processor block should expect when declaring or clearing the UNEQ-P and PLM-P defect conditions.
If the contents of the Received C2 Byte Value[7:0] (see Receive STS-1 Path - Received Path Label Value register)
matches the contents in these register, then the Receive STS-1 POH will not declare any defect conditions.
NOTE: The Receive STS-1 POH Processor block uses this register, along with the Receive STS-1 Path - Receive Path
Label Value Register (Address Location = 0x0296), when declaring or clearing the UNEQ-P and PLM-P defect
conditions.
TABLE 143: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0298)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B3_Byte_Error_Count[31:24]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B3 Byte Error Count - MSB
This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 2 through 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte
error.
NOTES:
1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then
it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3
SPE) that are in error.
2. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis,
then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred
B3 byte.
120
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 144: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0299)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B3_Byte_Error_Count[23:16]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B3 Byte Error Count (Bits 23 through 16)
This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 3, 1 and 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte
error.
NOTES:
1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then
it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3
SPE) that are in error.
2. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis,
then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred
B3 byte.
TABLE 145: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B3_Byte_Error_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B3 Byte Error Count - (Bits 15 through 8)
This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 3, 2 and 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte
error.
NOTES:
1.
If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then it will
increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3 SPE) that
are in error.
2.
If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis, then it will
increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred B3 byte.
TABLE 146: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B3_Byte_Error_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - B3 Byte Error Count - LSB
This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 3 through 1
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte
error.
NOTES:
121
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then
it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3
SPE) that are in error.
2. f the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis,
then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred
B3 byte.
TABLE 147: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X029C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-P Event_Count[31:24]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-P Event Count - MSB
This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 2 through 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the incoming STS-1/STS-3 SPE data-stream.
NOTES:
1.
If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it will
increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte within each
incoming STS-1/STS-3 SPE.
2.
If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis, then it will
increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a non-zero REI-P
value.
TABLE 148: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X029D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-P_Event_Count[23:16]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-P Event Count (Bits 23 through 16)
This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 3, 1 and 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the inconing STS-1/STS-3 SPE data-stream.
NOTES:
1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it
will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte within each
incoming STS-1/STS-3 frame.
2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis,
then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a nonzero REI-P value.
TABLE 149: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-P_Event_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
122
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT [7:0] - REI-P Event Count - (Bits 15 through 8)
This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 3, 2 and 0,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the incoming STS-1/STS-3 SPE data-stream.
NOTES:
1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it
will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte within each
incoming STS-1/STS-3 SPE.
2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis,
then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a nonzero REI-P value
TABLE 150: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-P_Event_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - REI-P Event Count - LSB
This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 3 through 1,
function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the incoming STS-1/STS-3 SPE data-stream.
NOTES:
1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it
will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte.
2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis,
then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a nonzero REI-P value.
TABLE 151: RECEIVE STS-1 PATH - RECEIVE PATH TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS
LOCATION= 0X02A3)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
New Message
Ready
Receive
Path Trace
Message
Buffer Read
Select
Receive
Path Trace
Message
Accept
Threshold
Path Trace
Message
Alignment
Type
BIT 1
BIT 0
Receive Path Trace
Message Length[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Unused
BIT 5 - New Message Ready
This READ/WRITE bit-field indicates whether or not the Receive Path Trace Message buffer has received a new
expected value.
` 0 - Indicates NO new expected value has been downloaded into the receive J1 trace buffer.
` 1 - Indicates a new expected value has been downloaded into the receive J1 trace buffer and can be used to make
comparisons with the accepted J1 message.
BIT 4 - Receive Section Trace Message Buffer Read Selection
This READ/WRITE bit-field is used to specify which of the following Receive Path Trace Message buffer segments to
123
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
read.
a. The Actual Receive Path Trace Message Buffer. The Actual Receive Path Trace Message Buffer contains the
contents of the most recently received (and accepted) Path Trace Message via the incoming STS-1/STS-3 data-stream.
b. The Expected Receive Path Trace Message Buffer. The Expected Receive Path Trace Message Buffer contains
the contents of the Path Trace Message that the user expects to receive. The contents of this particular buffer are
usually specified by the user.
` 0 - Executing a READ to the Receive J1 Trace Buffer, will return contents within the Valid Message buffer.
` 1 - Executing a READ to the Receive J1 Trace Buffer, will return contents within the Expected Message Buffer.
NOTE: In the case of the Receive STS-1 POH Processor block, the Receive J1 Trace Buffer is located at Address
Location 0x0500 through 0x053F.
BIT 3 - Path Trace Message Accept Threshold
This READ/WRITE bit-field is used to select the number of consecutive times that the Receive STS-1 POH Processor
block must receive a given Receive Trace Message, before it is accepted and loaded into the Receive Path Trace
Message.
` 0 - The Receive STS-1 POH Processor block accepts the Path Trace Message after it has received it the third time
in succession.
` 1 - The Receive SONET POH Processor block accepts the incoming Path Trace Message after it has received in the
fifth time in succession.
BIT 2 - Path Trace Message Alignment Type
This READ/WRITE bit-field is used to specify have the Receive STS-1 POH Processor block will locate the boundary
of the J1 Trace Message.
` 0 - Message boundary is indicated by Line Feed.
` 1 - Message boundary is indicated by the presence of a 1 in the MSB of a the first byte (within the J1 Trace Message).
BIT [1:0] - Path Trace Message Length[1:0]
These READ/WRITE bit-fields are used to specify the length of the Receive Path Trace Message that the Receive STS1 POH Processor block will receive. The relationship between the content of these bit-fields and the corresponding
Receive Path Trace Message Length is presented below.
Receive Trace Path Message Length
MSG LENGTH[1:0]
RESULTING PATH TRACE MESSAGE LENGTH
00
1 Byte
01
16 Bytes
10/11
64 Bytes
TABLE 152: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 1 (ADDRESS LOCATION= 0X02A6)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Current_Pointer ValueMSB[9:8]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:2] - Unused
BIT [1:0]Current Pointer Value - MSB
These READ-ONLY bit-fields, along with that from the Receive STS-1 Path - Pointer Value - Byte 0 Register combine
to reflect the current value of the pointer that the Receive STS-1 POH Processor block is using to locate the SPE within
the incoming STS-1/STS-3 data stream.Note
These register bits comprise the Upper Byte value of the Pointer Value.
124
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 153: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 0 (ADDRESS LOCATION= 0X02A7)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Current_Pointer_Value_LSB[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Current Pointer Value - LSB
These READ-ONLY bit-fields, along with that from the Receive STS-1 Path - Pointer Value - Byte 1 Register combine
to reflect the current value of the pointer that the Receive STS-1 POH Processor block is using to locate the SPE within
the incoming STS-1/STS-3 data stream.Note
These register bits comprise the Lower Byte value of the Pointer Value.
TABLE 154: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE VALUE REGISTER (ADDRESS = 0X02B9)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Defect_C2_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Defect_C2_Byte_Value[7:0]
These READ/WRITE bit-fields are used to configure the Receive STS-1 POH Processor block to automatically force
the transmission of the DS1/E1 AIS pattern (in the Egress Direction of all 28 channels) anytime it accepts a C2 byte
value matching that written into this register.
NOTE: The chip will only automatically transmit the DS1/E1 AIS Pattern if BIT 1 (Defect C2 Byte Downstream AIS
Enable), within the Receive STS-1 Path - Receive Auto AIS - C2 Byte Control Register is set to 1.
TABLE 155: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE CONTROL REGISTER (ADDRESS = 0X02BA)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Defect C2
Byte Downstream AIS
Enable
Unused
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/O
0
0
0
0
0
0
0
0
BIT [7:2] - Unused
BIT 1] - Defect C2 Byte Downstream AIS Enable
BIT 0 - Unused
125
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 156: RECEIVE STS-1 PATH - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X02BB)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Transmit
AIS-P
(Downstream)
Upon C2
Byte
Unstable
Transmit
AIS-P
(Downstream)
Upon
UNEQ-P
Transmit
AIS-P
(Downstream)
Upon PLM-P
Transmit
AIS-P
(Downstream)
Upon Path
Trace
Message
Unstable
Transmit
AIS-P
(Downstream) upon
TIM-P
Transmit
AIS-P
(Downstream) upon
LOP-P
Transmit
AIS-P
(Downstream)
Enable
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Unused
BIT 6 - Transmit Path AIS (Downstream) upon Declaration of the Unstable C2 Byte Defect Condition
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the
Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1
Framer blocks), anytime (and for the duration that) it declares the Unstable C2 Byte Defect condition within the incoming
STS-1/STS-3 data-stream.
` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the Unstable C2 Byte defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the Unstable C2 Byte defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor
block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 5 - Transmit Path AIS (Downstream) upon Declaration of the UNEQ-P (Path - Unequipped) Defect Condition
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the
Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1
Framer blocks), anytime (and for the duration that) it declares the UNEQ-P defect condition.
` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the UNEQ-P defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the UNEQ-P defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor
block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 4 - Transmit Path AIS (Downstream) upon Declaration of the PLM-P (Path - Payload Label Mismatch) Defect
Condition
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the
Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1
Framer blocks), anytime (and for the duration that) it declares the PLM-P defect condition.
` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the PLM-P defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the PLM-P defect condition.Note
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor
block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 3 - Transmit Path AIS (Downstream) upon declaration of the Path Trace Message Unstable Defect Condition
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the
Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1
Framer blocks), anytime (and for the duration that) it declares the Path Trace Message Unstable defect condition within
126
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
the incoming STS-1/STS-3 data-stream.
` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the Path Trace Message Unstable defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic) whenever it declares the Path Trace Message Unstable defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor
block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 2 - Transmit Path AIS (Downstream) upon declaration of the TIM-P (Path Trace Message Identification
Mismatch) defect condition
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit a
Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1
Framer blocks), anytime (and for the duration that) it declares the TIM-P defect condition within the incoming STS1/STS-3 data-stream.
` 0 - Does not configure the Receive STS-1 POH Processor block to transmit the AIS-P indicator (via the downstream
traffic) whenever it declares the TIM-P defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to transmit the AIS-P indicator (via the downstream traffic)
whenever it declares the TIM-P defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor
block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 1 - Transmit Path AIS (Downstream) upon Detection of Loss of Pointer (LOP-P) Defect Condition
This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the
Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1
Framer blocks), anytime (and for the duration that) it declares the LOP-P defect condition within the incoming STS1/STS-3 data-stream.
` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic, towards the corresponding Transmit SONET POH Processor block) whenever it declares the LOPP defect condition.
` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic, towards the corresponding Transmit SONET POH Processor block) whenever it declares the LOPP defect condition.
NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor
block to automatically transmit the AIS-P indicator, in response to this defect condition.
BIT 0 - Automatic Transmission of AIS-P Enable
This READ/WRITE bit-field serves two purposes.
•
It is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS
indicator, via the down-stream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer
blocks), upon detection of an UNEQ-P, PLM-P, LOP-P or LOS conditions.
•
It also is used to configure the Receive STS-1 POH Processor block to automatically transmit a Path (AIS-P)
Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer
blocks) anytime it detects an AIS-P condition in the incoming STS-1/STS-3 data-stream.
` 0 - Configures the Receive STS-1 POH Processor block to NOT automatically transmit the AIS-P indicator (via the
downstream traffic, towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks) whenever it declares any
of the above-mentioned defect conditions.
` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the
downstream traffic, towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks) whenever it declares any
of the above-mentioned defect condition.
NOTE: The user must also set the corresponding bit-fields (within this register) to 1 in order to configure the Receive
STS-1 POH Processor block to automatically transmit the AIS-P indicator upon detection of a given
alarm/defect condition.
127
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 157: RECEIVE STS-1 PATH - SONET RECEIVE AUTO ALARM REGISTER - BYTE 0 (ADDRESS LOCATION=
0X02C3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Transmit AIS
(via
Downstream
T1/E1s)
upon LOP-P
Transmit AIS
(via Downstream
T1/E1s)
uponPLM-P
Unused
Transmit AIS
(via Downstream
T1/E1s)
upon UNEQP
Transmit AIS
(via Downstream
T1/E1s)
upon TIM-P
Transmit AIS
(via Downstream
T1/E1s)
upon AIS-P
Unused
R/W
R/W
R/W
R/O
R/W
R/W
R/W
R/O
0
0
0
0
0
0
0
0
BIT 7 - Unused
BIT 6 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the LOP-P defect condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that)
the Receive STS-1 POH Processor block declares the LOP-P defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1 POH Processor block declares
the LOP-P defect.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that) the Receive STS-1 POH Processor
block declares the LOP-P defect.
BIT 5 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the PLM-P defect condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that)
the Receive STS-1 POH Processor block declares the PLM-P defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1 POH Processor block declares
the PLM-P defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH
Processor block declares the PLM-P defect condition.
BIT 4 - Unused
BIT 3 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the UNEQ-P defect condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that)
the Receive STS-1 POH Processor block declares the UNEQ-P defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1 POH Processor block declares
the UNEQ-P defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH
Processor block declares the UNEQ-P defect condition.
BIT 2 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the TIM-P defect condition
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that)
the Receive STS-1 POH Processor block declares the TIM-P defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1 POH Processor block declares
128
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
the TIM-P defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1
AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH
Processor block declares the TIM-P defect condition.
BIT 1 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon AIS-P
This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to
automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that)
the Receive STS-1 POH Processor block declares the AIS-P defect condition.
` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the
DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1 POH Processor block declares
the AIS-P defect condition.
` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the AIS-P
Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor
block declares the AIS-P defect condition.
BIT 0 - Unused
TABLE 158: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1
(ADDRESS = 0X02C4)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive Negative Pointer Adjustment Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Negative Pointer Adjustment Count - MSB
These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Negative Pointer Adjustment Count
Register - Byte 0 present a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that
the Receive STS-1 POH Processor block has detected since the last read of these registers.
NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression.
TABLE 159: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0
(ADDRESS = 0X02C5)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive Negative Pointer Adjustment Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Negative Pointer Adjustment Count - LSB
These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Negative Pointer Adjustment Count
Register - Byte 1 present a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that
the Receive STS-1 POH Processor block has detected since the last read of these registers.
NOTE: This register contains the LSB (Least Significant Bits) of this 16-bit expression.
129
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 160: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1
(ADDRESS = 0X02C6)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive Positive Pointer Adjustment Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Positive Pointer Adjustment Count - MSB
These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Positive Pointer Adjustment Count
Register - Byte 0 present a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that
the Receive STS-1 POH Processor block has detected since the last read of these registers.
NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression.
TABLE 161: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0
(ADDRESS = 0X02C7)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive Positive Pointer Adjustment Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Positive Pointer Adjustment Count - LSB
These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Positive Pointer Adjustment Count
Register - Byte 1 present a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that
the Receive STS-1 POH Processor block has detected since the last read of these registers.
NOTE:
This register contains the LSB (Least Significant Bits) of this 16-bit expression.
TABLE 162: RECEIVE STS-1 PATH - RECEIVE J1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
J1_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - J1 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the J1 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new J1 byte value.
TABLE 163: RECEIVE STS-1 PATH - RECEIVE B3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D7)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B3_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - B3 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the B3 byte, within the most recently received STS-1/STS-3 frame.
130
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new B3 byte value.
TABLE 164: RECEIVE STS-1 PATH - RECEIVE C2 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DB)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
C2_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - C2 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the C2 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new C2 byte value.
TABLE 165: RECEIVE STS-1 PATH - RECEIVE G1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DF)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
G1_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - G1 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the G1 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new G1 byte value.
TABLE 166: RECEIVE STS-1 PATH - RECEIVE F2 BYTE CAPTURE REGISTER (ADDRESS LOCATION=0X02E3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
F2_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - F2 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the F2 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new F2 byte value.
TABLE 167: RECEIVE STS-1 PATH - RECEIVE H4 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02E7)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
H4_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - H4 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the H4 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new H4 byte value.
131
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 168: RECEIVE STS-1 PATH - RECEIVE Z3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EB)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Z3_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Z3 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the Z3 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new Z3 byte value.
TABLE 169: RECEIVE STS-1 PATH - RECEIVE Z4 (K3) BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EF)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Z4(K3)_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Z4 (K3) Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the Z4 (K3) byte, within the most recently received STS-1/STS-3
frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3
frame period, this value will be overridden with a new Z4 (K3) byte value.
TABLE 170: RECEIVE STS-1 PATH - RECEIVE Z5 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02F3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Z5_Byte_Captured_Value[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Z5 Byte Captured Value[7:0]
These READ-ONLY bit-fields contain the value of the Z5 byte, within the most recently received STS-1/STS-3 frame.
This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame
period, this value will be overridden with a new Z5 byte value.
132
PRELIMINARY
REV. P1.0.6
2.5
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
RECEIVE TUG-3 MAPPER/VC-4
APPLICATIONS ONLY)
POH
PROCESSOR
BLOCK
REGISTERS
(SDH/TUG-3
The register map for the Receive TU-3 Mapper/VC-4 POH Processor block is presented and discussed in
detail within the "SDH Version of the Register Map".
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328 device, with the Receive TUG-3 Maper/VC-4 POH Processor block "highlighted" is presented
below in Figure 5.
FIGURE 5. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE RECEIVE
TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK "HIGHLIGHTED"
Transmit
Transmit
STM-1
STM-1
SOH
SOH
Processor
Processor
Block
Block
Transmit
Transmit
TUG-3
TUG-3
Mapper/
Mapper/
VC-4
VC-4POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Transmit
Transmit
VC-3
VC-3POH
POH
Processor
Processor
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From TU Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
STS-1/
STS-1/
STM-0
STM-0
Telecom
Telecom
Bus
Bus
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
Receive
Receive
TUG-3
TUG-3
Mapper/
Mapper/
VC-4
VC-4
POH
POH
Processor
Processor
Block
Block
Receive
Receive
VC-3
VC-3POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To TU
Channels 1 - 27
Receive
Receive
STM-1
STM-1
SOH
SOH
Processor
Processor
Block
Block
From DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
For detailed on the "Receive TUG-3 Mapper/VC-4 POH Processor Block" Registers, please see the
"XRT86SH328 28-Channel DS1/E1 Framer/LIU with DS3 MUX and TU-Mapper IC - Register Map &
Description - SDH Applications"
2.6
TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS
The register map for the Transmit STS-1/STS-3 TOH Processor block is presented in the Table below.
Additionally, a detailed description of each of the Transmit STS-1/STS-3 TOH Processor Block registers is
presented below.
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328, with the Transmit STS-1/STS-3 TOH Processor Block highlighted is presented below in
Figure 6.
133
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
FIGURE 6. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
TABLE 171: TRANSMIT STS-1/STS-3 TRANSPORT- TRANSMIT CONTROL REGISTER - BYTE 3 (ADDRESS LOCATION =
0X0700)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
Control_Pointer[3:0]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT [3:0] - Control_Pointer[3:0]
134
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 172: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION
= 0X0701)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Auto Transmit AIS-L
Enable
Section DCC
Relocate
Line DCC
Relocate
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:3] - Unused
BIT 2 - Auto Transmit AIS-L Enable
BIT 1 - Section DCC Relocate
BIT 0 - Line DCC Relocate
TABLE 173: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION=
0X0702)
BIT 7
BIT 6
Reserved
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
E2 InsertMethod
E1 Insert
Method
F1 Insert
Method
S1 Insert
Method
K1K2 Insert
Method
M0M1 Insert
Method[1]
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Unused
BIT 5 - E2 Byte Insert Method
This READ/WRITE bit-field is used to specify the source of the contents of the E2 byte, within the transmit output STS1/STS-3 or STS-3 data stream.
0 - E2 Byte is obtained from TxTOH Serial Input Port.]
1 - E2 Byte is obtained from the contents within the Transmit Transport - E2 Byte Value register (Address Location =
0x0747). This selection provides the user with software control over the value of the outbound E2 byte.
BIT 4 - E1 Byte Insert Method
This READ/WRITE bit-field is used to specify the source of the contents of the E1 byte, within the transmit output STS1 or STS-3 data stream.
0 - E1 Byte is obtained from TxTOH Serial Input Port.
1 - E1 Byte is obtained from the contents within the Transmit Transport - E1 Byte Value register (Address Location=
0x0743). This selection provides the user with software control over the value of the outbound E1 byte.
BIT 3 - F1 Byte Insert Method
This READ/WRITE bit-field is used to specify the source of the contents of the F1 byte, within the transmit output STS1 or STS-3 data stream.
0 - F1 Byte is obtained from TxTOH Serial Input Port.
1 - F1 Byte is obtained from the contents within the Transmit Transport - F1 Byte Value register (Address Location=
0x073F). This selection provides the user with software control over the value of the outbound F1 byte.
BIT 2 - S1 Byte Insert Method
This READ/WRITE bit-field is used to specify the source of the contents of the S1 byte, within the transmit output STS1 or STS-3 data stream.
0 - S1 Byte is obtained from TxTOH Serial Input Port.
1 - S1 Byte is obtained from the contents within the Transmit Transport - S1 Byte Value register (Address Location=
0x073B). This selection provides the user with software control over the value of the outbound S1 byte.
135
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT 1 - K1K2 Byte Insert Method
This READ/WRITE bit-field is used to specify the source of the contents of the K1 and K2 bytes, within the transmit
output STS-1 or STS-3 data stream.
0 - K1 and K2 Bytes are obtained from TxTOH Serial Input Port.
1 - K1 and K2 Bytes are obtained from the contents within the Transmit Transport - K1K2 Byte Value register - Byte 1
(Address Location= 0x072E) and the Transmit Transport - K1K2 Byte Value register - Byte 2 (Address Location=
0x072F). This selection provides the user with software control over the value of the outbound K1 and K2 bytes.
BIT 0 - M0M1 Insert Method
This READ/WRITE bit-field, along with M0M1 Insert Method[0] (located in the Transmit Transport - SONET Control
Register - Byte 0) are used to specify the source of the contents of the M0/M1 byte, within the transmit output STS-1 or
STS-3 data stream. The relationship between these two bit-fields and the corresponding source of the M0/M1 byte is
presented below.
Source of M)/M1 Byte
M0M1 INSERT
METHOD[1:0]
SOURCE OF M0/M1 BYTE
0
0
From the Receive STS-1/STS-3 TOH Processor block (B2 byte (or BIP-24) Error Count)
0
1
Obtained from the contents of the Transmit STS-1/STS-3 Transport - M0/M1 Byte Value
register (Address Location= 0x0737).
1
0
M0/M1 byte is obtained from the TxTOH Serial Input Port.
1
1
From the Receiver STS-1/STS-3 TOH Processor block (B2 byte (or BIP-24) Error Count).
TABLE 174: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION=
0X0703)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M0M1 Insert
Method[0]
Unused
RDI-L Force
AIS-L Force
LOSForce
Scramble
Enable
B2 Error
Insert
A1A2 Error
Insert
R/W
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - M0M1 Insert Method
This READ/WRITE bit-field, along with M0M1 Byte Insert Method[1] (located in the Transmit STS-1/STS-3 Transport SONET Control Register - Byte 1) are used to specify the source of the contents of the M0/M1 byte, within the transmit
output STS-1 or STS-3 data stream. The relationship between these two bit-fields and the corresponding source of the
M0/M1 byte is presented below.
Source of M0/M1 Byte
M0M1 BYTE
INSERT
METHOD[1:0]
SOURCE OF M0/M1 BYTE
0
0
From the Receive STS-1/STS-3 TOH Processor block (B2 Byte Error Count)
0
1
Obtained from the contents of the Transmit STS-1/STS-3 Transport - M0/M1 Byte Value register (Address Location= 0x0737).
1
0
M0/M1 byte is obtained from the TxTOH Serial Input Port.
1
1
From the Receive STS-1/STS-3 TOH Processor block (B2 Byte Error Count).
136
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT6 - Unused
BIT 5 - Transmit Line - Remote Defect Indicator
This READ/WRITE bit-field is used to (by software control) force the Transmit STS-1/STS-3 TOH Processor block to
generate and transmit the RDI-L indicator to the remote terminal equipment.
` 0 - Does not configure the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the RDI-L indicator.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the RDI-L indicator.
In this case, the Transmit STS-1/STS-3 TOH Processor block will force bits 6, 7 and 8 (of the K2 byte) to the value 1,
1, 0.
NOTE: This bit-field is ignored if the Transmit STS-1/STS-3 TOH Processor block is currently transmitting the Line AIS
(AIS-L) indicator or LOS pattern.
BIT 4 - Transmit Line - AIS Indicator
This READ/WRITE bit-field is used to (by software control) force the Transmit STS-1/STS-3 TOH Processor block to
generate and transmit the AIS-L indicator to the remote terminal equipment.
` 0 - Does not configure the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the AIS-L indicator.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the AIS-L indicator.
In this case, the Transmit STS-1/STS-3 TOH Processor block will force all bits (within the outbound STS-1 or STS-3
frame) with the exception of the Section Overhead Bytes to an All Ones pattern.
NOTE: This bit-field is ignored if the Transmit STS-1/STS-3 TOH Processor block is transmitting the LOS pattern.
BIT 3 - Transmit LOS Pattern
This READ/WRITE bit-field is used to (by software control) force the Transmit STS-1/STS-3 TOH Processor block to
transmit the LOS (Loss of Signal) pattern to the remote terminal equipment.
` 0 - Does not configure the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the LOS pattern.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to transmit the LOS pattern. In this case, the
Transmit STS-1/STS-3 TOH Processor block will force all bytes (within the outbound SONET frame) to an All Zeros
pattern.
BIT 2 - Scramble Enable
This READ/WRITE bit-field is used to either enable or disable the Scrambler, within the Transmit STS-1/STS-3 TOH
Processor block circuitry.
` 0 - Disables the Scrambler.
` 1 - Enables the Scrambler.
BIT 1 - Transmit B2 Byte Error Insert Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to insert errors into
the outbound B2 bytes, per the contents within the Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Mask
Register.
` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT insert errors into the B2 bytes, within the
outbound STS-1 or STS-3 signal.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to insert into the B2 bytes (per the contents within
the Transmit B2 Byte Error Mask Register).
BIT 0 - Transmit A1A2 Byte Error Insert Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to insert errors into
the outbound A1 and A2 bytes, within the outbound STS-1 or STS-3 data-stream.
` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT insert errors into the A1 and A2 bytes, within
the outbound STS-1 or STS-3 Data-stream.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to insert errors into the A1 and A2 bytes, within the
outbound STS-1 or STS-3 Data-stream.
137
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 175: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A1 BYTE ERROR REGISTER (ADDRESS LOCATION =
0X0717)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Transmit Erred
A1Byte Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:1] - Unused
BIT 0 - Transmit Erred A1 Byte Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to transmit a
continuous stream of STS-1 or STS-3 frames, in which the A1 byte is erred.
` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT transmit STS-1 or STS-3 frames with erred
A1 bytes.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to transmit STS-1 or STS-3 frames with erred A1
bytes.
TABLE 176: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A2 BYTE ERROR REGISTER (ADDRESS LOCATION =
0X071F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Transmit Erred
A2 Byte Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:1] - Unused
BIT 0 - Transmit Erred A2 Byte Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to transmit a
continuous stream of STS-1 or STS-3 frames, in which the A2 byte is erred.
` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT transmit STS-1 or STS-3 frames with erred
A2 bytes.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to transmit STS-1 or STS-3 frames with erred A2
bytes.
TABLE 177: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B1 BYTE ERROR MASK REGISTER (ADDRESS
LOCATION = 0X0723)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
B1_Byte_Error_Mask[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0]B1 Byte Error Mask[7:0]
These READ/WRITE bit-fields are used to insert bit errors into the B1 bytes, within the outbound STS-1 or STS-3 Data
stream. The Transmit STS-1/STS-3 TOH Processor block will perform an XOR operation with the contents of the B1
byte, and this register. The results of this calculation will be inserted into the B1 byte position within the outbound STS1 or STS-3 Data stream. For each bit-field (within this register) that is set to 1, the corresponding bit, within the B1 byte
will be in error.
138
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: For normal operation, the user should set this register to 0x00.
TABLE 178: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BYTE ERROR MASK REGISTER (ADDRESS
LOCATION = 0X0727)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
Transmit B2 Error
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:1] - Unused]
BIT 0 - Transmit B2 Byte Error Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to perform the XOR
operation with the contents of the Transmit STS-1/STS-3 Transport -Transmit B2 Bit Error Mask Register (Address
Location = 0x072B)
` 0 - Disables the XOR operation. In this case, the Transmit STS-1/STS-3 TOH Processor block will NOT perform the
XOR operation with the Transmit STS-1/STS-3 Transport - Transmit B2 Bit Error Mask Register. As a consequence,
the Transmit STS-1/STS-3 TOH Processor block will transmit a continuous stream of STS-1s with no B2 byte errors.
` 1 - Enables the XOR operation. In this setting, the Transmit STS-1/STS-3 TOH Processor will perform the XOR
operation of the value of the B2 byte (within the outbound STS-1 or STS-3 frame) with the contents within the Transmit
STS-1/STS-3 Transport - Transmit B2 Bit Error Mask register.
TABLE 179: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BIT ERROR MASK REGISTER (ADDRESS
LOCATION= 0X072B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_B2_Error_Mask[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit B2 Error Mask-Byte
These READ/WRITE bit-fields are used to insert B2 byte errors into the outbound STS-1 or STS-3 Data-stream, for
diagnostic purposes.
If BIT 0 (Transmit B2 Error Enable) within the Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Register
(Address Location = 0xN927) is set to 1, then Transmit STS-1/STS-3 TOH Processor block will be configured to perform
an XOR operation between the contents of this register, with the contents of the outbound B2 byte. The results of this
calculation is written back into the B2 byte position, within the outbound STS-1 or STS-3 Data. Hence, for every bit
(within this register) that is set to 1, the corresponding bit (within the outbound B2 byte) will be erred.
NOTES:
1.
1. For normal (e.g., un-erred) operation, the user should ensure that this register is set to the value 0x00.
2. These register bits are ignored unless BIT 0 (Transmit B2 Error Enable), within the Transmit STS-1/STS3 Transport - Transmit B2 Byte Error Register has been set to 1.
139
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 180: TRANSMIT STS-1/STS-3 TRANSPORT - K2 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION=
0X072E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_K2_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit K2 Byte Value
If the appropriate K1K2 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the
contents of the K2 byte, within the outbound STS-1/STS-3 signal.
NOTE: If BIT 1 (K1K2 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load
the contents of this register into the K2 byte-field, within each outbound STS-1 or STS-3 frame. These register
bits are ignored if BIT 1 (K1K2 Insert Method) is set to 0.
TABLE 181: TRANSMIT STS-1/STS-3 TRANSPORT - K1 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION=
0X072F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_K1_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit K1 Byte Value
If the appropriate K1K2 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the
contents of the K1 byte, within the outbound STS-1/STS-3 signal.
NOTE: If BIT 1 (K1K2 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load
the contents of this register into the K1 byte-field, within each outbound STS-1 or STS-3 frame. These register
bits are ignored if BIT 1 (K1K2 Insert Method) is set to 0.
TABLE 182: TRANSMIT STS-1/STS-3 TRANSPORT - RDI-L CONTROL REGISTER (ADDRESS LOCATION= 0X0733)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
External
RDI-L
Enable
Transmit
RDI-L upon
AIS
Transmit
RDI-L upon
LOF
Transmit
RDI-L upon
LOS
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT 3 - External Transmit Line Remote Defect Indicator (RDI-L) Enable
This READ/WRITE bit-field is used to externally insert the value for bits 6, 7 and 8 (of the K2 byte) into the outbound
STS-1 or STS-3 Data stream. If the user enables this feature, then the user can enable or disable the insertion of the
RDI-L indicator, via the TxPOH_n input pin.
0 - Disables this feature.
1 - Enables this feature.
BIT 2 - Transmit Line Remote Defect Indicator (RDI-L) upon Detection of AIS-L
140
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to automatically
transmit a RDI-L indicator to the remote terminal anytime (and for the duration) that the Receive STS-1/STS-3 TOH
Processor block is detecting a Line AIS (AIS-L) indicator.
` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT automatically transmit the RDI-L indicator,
upon the Receive STS-1/STS-3 TOH Processor block detecting the AIS-L indicator.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to automatically transmit the RDI-L indicator, upon
the Receive STS-1/STS-3 TOH Processor block detecting the AIS-L indicator.
BIT 1 - Transmit Line Remote Defect Indicator (RDI-L) upon Detection of LOF
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to automatically
transmit a RDI-L indicator to the remote terminal anytime (and for the duration) that the Receive STS-1/STS-3 TOH
Processor block is declaring the LOF defect
` .0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT automatically transmit the RDI-L indicator,
whenever the Receive STS-1/STS-3 TOH Processor block declares the LOF defect.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to automatically transmit the RDI-L indicator,
whenever the Receive STS-1/STS-3 TOH Processor block declares the LOF defect.
BIT 0 - Transmit Line Remote Defect Indicator (RDI-L) upon Detection of LOS
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to automatically
transmit a RDI-L indicator to the remote terminal anytime (and for the duration) that the Receive STS-1/STS-3 TOH
Processor block is declaring the LOS defect.
` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT automatically transmit the RDI-L indicator,
whenever the Receive STS-1/STS-3 TOH Processor block declares the LOS defect.
` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to automatically transmit the RDI-L indicator,
whenever the Receive STS-1/STS-3 TOH Processor block declares the LOS defect.
TABLE 183: TRANSMIT STS-1/STS-3 TRANSPORT - M0M1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0737)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_M0M1_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit M0M1 Byte Value
If the appropriate M0M1 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the
contents of the M0M1 byte, within the outbound STS-1/STS-3 signal.
NOTE: If BIT 0 (M0M1 Insert Method - BIT 1) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control
Register - Byte 1 (Address Location= 0x0702) and BIT7 (M0M1 Byte Insert Method - BIT 0) within the Transmit
STS-1/STS-3 Transport - SONET Transmit Control Register - Byte 0 (Address Location= 0x0703) are set to 0,
1, then the STS-1/STS-3 Transmit block will load the contents of this register into the M0M1 byte-field, within
each outbound STS-1 or STS-3 frame. These register bits are ignored if the M0M1 Insert Method[1:0] bits are
set to any value other than 0, 1.
TABLE 184: TRANSMIT STS-1/STS-3 TRANSPORT - S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_S1_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit S1 Byte Value
If the appropriate S1 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents
of the S1 byte, within the outbound STS-1/STS-3 signal. If BIT 2 (S1 Insert Method) within the Transmit STS-1/STS-3
141
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Transport - SONET Transmit Control Register - Byte 1 (Address Location= 0x0702) is set to 1, then the STS-1/STS-3
Transmit block will load the contents of this register into the S1 byte-field, within each outbound STS-1 or STS-3 frame.
NOTE: These register bits are ignored if BIT 2 (S1 Insert Method) is set to 0.
TABLE 185: TRANSMIT STS-1/STS-3 TRANSPORT - F1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_F1_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit F1 Byte Value
If the appropriate F1 Byte Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the
contents of the F1 byte, within the outbound STS-1/STS-3 signal.
NOTE: If BIT 3 (F1 Byte Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register
- Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load
the contents of this register into the F1 byte-field, within each outbound STS-1 or STS-3 frame. These register
bits are ignored if BIT 3 (F1 Insert Method) is set to 0.
TABLE 186: TRANSMIT STS-1/STS-3 TRANSPORT - E1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0743)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_E1_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit E1 Byte Value
If the appropriate E1 Byte Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the
contents of the E1 byte, within the outbound STS-1/STS-3 signal. Note
NOTE: If BIT 4 (E1 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load
the contents of this register into the E1 byte-field, within each outbound STS-1 or STS-3 frame. These register
bits are ignored if BIT 4 (E1 Insert Method) is set to 0.
TABLE 187: TRANSMIT STS-1/STS-3 TRANSPORT - E2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0747)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_E2_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit E2 Byte Value
If the appropriate E2 Byte Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the
contents of the E2 byte, within the outbound STS-1/STS-3 signal.
NOTE: If BIT 5 (E2 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load
the contents of this register into the E2 byte-field, within each outbound STS-1 or STS-3 frame. These register
bits are ignored if BIT 5 (E2 Insert Method) is set to 0.
142
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 188: TRANSMIT STS-1/STS-3 TRANSPORT - J0 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X074B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_J0_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit J0 Byte Value
These READ/WRITE bits are used to specify the value of the J0 byte, that will be transmitted via the Transport
Overhead, within the very next STS-1 or STS-3 frame. This register is only valid if the Transmit STS-1/STS-3 TOH
Processor block is configured to read out the contents from this register and insert it into the J0 byte-field within each
outbound STS-1 or STS-3 frame. The user accomplishes this by setting Bits 1 and 0 (J0_TYPE), within the Transmit
STS-1/STS-3 Transport - J0 Byte Control Register (Address Location= 0x074F) to 1, 0.
TABLE 189: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMITTER J0 BYTE CONTROL REGISTER (ADDRESS
LOCATION= 0X074F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
Message Length[1:0]
BIT 0
J0_TYPE[1:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT [3:2] - Message Length[1:0]
These two READ/WRITE bit-fields are used to specify the length of the message that is to be repetitively transmitted
via the J0 byte as shown in the table below.
J
Message Length
MSG_LENGTH[1:0]
CORRESPONDING MESSAGE LENGTH(BYTES)
00
1 Byte
01
16 Bytes
10 or 11
64 Bytes
BIT [1:0] - Transmit J0 Source[1:0]
These two READ/WRITE bit-fields are used to specify the source of the message that will be transported via the J0
byte/message, within the outbound STS-1 or STS-3 Data-stream, as shown in the table below
Source of J0 Byte Message
0_TYPE[1:0]
CORRESPONDING SOURCE OF J0 BYTE/MESSAGE.
00
Automatically set the J0 Byte, in each outbound STS-1 or STS-3 frame to 0x01.
01
The Transmit Section TraceMessage BufferThe Transmit STS-1/STS-3 Section Trace Buffer
Memory is located at Address locations 0x0900 through 0x093F.
143
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Source of J0 Byte Message
0_TYPE[1:0]
CORRESPONDING SOURCE OF J0 BYTE/MESSAGE.
10
From the Transmit J0 Byte Value[7:0] Register. In this setting, the Transmit STS-1/STS-3
TOH Processor block will read out the contents of the Transmit J0 Value[7:0] Register
(Address Location= 0x074B), and will insert this value into the J0 byte of each outbound STS1 or STS-3 frame.
11
From the TxPOH_n Input pin.
144
PRELIMINARY
REV. P1.0.6
2.7
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS
The register map for the Transmit STS-1/STS-3 POH Processor block is presented in the Table below.
Additionally, a detailed description of each of the Transmit STS-1/STS-3 POH Processor block registers is
presented below.
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328, with the Transmit STS-1/STS-3 POH Processor block highlighted is presented below in
Figure 7.
FIGURE 7. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS1/STS-3 POH PROCESSOR BLOCK HIGHLIGHTED
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
TABLE 190: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION =
0X0781)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Payload_Type[1:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:2] - Unused
BIT [1:0] - Payload_Type[1:0]
145
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 191: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION =
0X0782)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Z5 InsertionType
Z4 InsertionType
Z3 InsertionType
H4 Insertion
Type
R/W
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT 3 - Z5 Insertion Type
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the
Transmit STS-1/STS-3 Path - Transmit Z5 Value Register or the TPOH input pin as the source for the Z5 byte, in the
outbound STS-1/STS-3 SPE.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit
Z5 Value Register (Address Location= 0x07B3).
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the Z5 byte,
in the outbound STS-1/STS-3 SPE.
BIT 2 - Z4 Insertion Type
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the
Transmit STS-1/STS-3 Path - Transmit Z4 Value Register or the TPOH input pin as the source for the Z4 byte, in the
outbound STS-1/STS-3 SPE.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit
Z4 Value Register (Address Location= 0x07AF).
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the Z4 byte,
in the outbound STS-1/STS-3 SPE.
BIT 1 - Z3 Insertion Type
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the
Transmit STS-1/STS-3 Path - Transmit Z3 Value Register or the TPOH input pin as the source for the Z3 byte, in the
outbound STS-1/STS-3 SPE.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit
Z3 Value Register (Address Location = 0x07AB).
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the Z3 byte,
in the outbound STS-1/STS-3 SPE.
BIT 0 - H4 Insertion Type
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the
Transmit STS-1/STS-3 Path - Transmit H4 Value Register or the TPOH input pin as the source for the H4 byte, in the
outbound STS-1/STS-3 SPE.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit
H4 Value Register (Address Location= 0x07A7).
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the H4 byte,
in the outbound STS-1/STS-3 SPE.
146
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 192: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION=
0X0783)
BIT 7
BIT 6
F2 Insertion
Type
BIT 5
REI-P Insertion Type[1:0]
BIT 4
BIT 3
RDI-P Insertion Type[1:0]
BIT 2
BIT 1
BIT 0
C2 Byte
Insertion
Type
C2 Byte Auto
Insert Mode
Enable
Transmit
AIS-P
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - F2 Insertion Type
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the
Transmit STS-1/STS-3 Path - Transmit F2 Value Register or the TPOH input pin as the source for the F2 byte, in the
outbound STS-1/STS-3 SPE.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit
F2 Value Register (Address Location= 0x07A3).
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the F2 byte,
in the outbound STS-1/STS-3 SPE.
BIT [6:5] - REI-P Insertion Type[1:0]
These two READ/WRITE bit-fields are used to configure the Transmit STS-1/STS-3 POH Processor block to use one
of the three following sources for the REI-P bit-fields (e.g., bits 1 through 4, within the G1 byte of the outbound STS1/STS-3 SPE).
•
From the corresponding Receive STS-1/STS-3 POH Processor block (e g., when it detects B3 bytes in its
incoming SPE data).
•
From the Transmit G1 Byte Value Register (Address Location= 0x079F).
•
From the TPOH input pin.
` 00/11 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 1 through 4 (in the G1 byte of the
outbound SPE) based upon receive conditions as detected by the corresponding Receive STS-1/STS-3 POH Processor
block.
` 01 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 1 through 4 (in the G1 byte of the
outbound SPE) based upon the contents within the Transmit G1 Byte Value register (Address Location= 0x079F).
` 10 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input pin as the source of Bits 1
through 4 (in the G1 byte of the outbound SPE).
BIT [4:3] - RDI-P Insertion Type[1:0]
These two READ/WRITE bit-fields are used to configure the Transmit STS-1/STS-3 POH Processor block to use one
of the three following sources for the RDI-P bit-fields (e.g., bits 5 through 7, within the G1 byte of the outbound STS1/STS-3 SPE).
•
From the Receive STS-1/STS-3 POH Processor block (e g., when it detects various alarm conditions within
its incoming SPE data).
•
From the Transmit G1 Byte Value Register (Address Location = 0x079F).
•
From the TPOH input pin.
` 00/11 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 5 through 7 (in the G1 byte of the
outbound SPE) based upon receive conditions as detected by the Receive STS-1/STS-3 POH Processor block.
` 01 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 5 through 7 (in the G1 byte of the
outbound SPE) based upon the contents within the Transmit G1 Byte Value register.
` 10 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input pin as the source of Bits 5
through 7 (in the G1 byte of the outbound SPE).
BIT 2 - C2 Insertion Type
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the
Transmit STS-1/STS-3 Path - Transmit C2 Byte Value Register or the TPOH input pin as the source for the C2 byte, in
147
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
the outbound STS-1/STS-3 SPE.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit
C2 Value Register (Address Location= 0x079B).
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the C2 byte,
in the outbound STS-1/STS-3 SPE.
BIT 1 - Auto-Insert PDI-P Indicator Enable
This READ/WRITE bit-field are used to configure the Transmit STS-1/STS-3 POH Processor block to automatically
insert the PDI-P (Path - Payload Defect Indicator) whenever the AIS-P indicator is received from the Receive SONET
POH Processor block.
If this feature is enabled, then the Transmit STS-1/STS-3 POH Processor block will automatically set the C2 byte (within
the outbound SPE) to 0xFC (to indicate a PDI-P condition) whenever it receives the AIS-P indicator, from the Receive
SONET POH Processor block.
BIT 0 - Transmit AIS-P Enable
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to (via software
control) transmit an AIS-P indicator to the remote PTE.If this feature is enabled, then the Transmit STS-1/STS-3 POH
Processor block will automatically set the H1, H2, H3 and all the SPE bytes to an All Ones pattern, prior to routing this
data to the Transmit STS-1/STS-3 TOH Processor block.
` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to NOT transmit the AIS-P indicator to the remote
PTE.
` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to transmit the AIS-P indicator to the remote PTE.
TABLE 193: TRANSMIT STS-1/STS-3 PATH - TRANSMITTER J1 BYTE VALUE REGISTER (ADDRESS LOCATION=
0X0793)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_J1_Byte[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit J1 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the J1 byte, within each outbound
STS-1/STS-3 SPE.
If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the J1 byte, then
it will automatically write the contents of this register into the J1 byte location, within each outbound STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT 2 (C2 Insertion Type) within the Transmit STS-1/STS-3
Path - J1 Control Register register (Address Location= 0x0783).
TABLE 194: TRANSMIT STS-1/STS-3 PATH - TRANSMIT B3 BYTE ERROR MASK REGISTER (ADDRESS LOCATION=
0X0797)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_B3_Byte_Mask[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit B3 Byte Mask[7:0]
This READ/WRITE bit-field is used to insert errors into the B3 byte, within the outbound STS-1/STS-3 SPE, prior to
transmission to the Transmit STS-1/STS-3 TOH Processor block.
The Transmit STS-1/STS-3 POH Processor block will perform an XOR operation with the contents of this register, and
the B3 byte value. The results of this operation will be written back into the B3 byte of the outbound STS-1/STS-3 SPE.
148
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: If the user sets a particular bit-field, within this register, to 1, then that corresponding bit, within the outbound B3
byte will be in error. For normal operation, the user should set this register to 0x00.
TABLE 195: TRANSMIT STS-1/STS-3 PATH - TRANSMIT C2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_C2_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit C2 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the C2 byte, within each outbound
STS-1/STS-3 SPE.
If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the C2 byte, then
it will automatically write the contents of this register into the C2 byte location, within each outbound STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT 2 (C2 Byte Insertion Type) within the Transmit STS-1/STS3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0783).
TABLE 196: TRANSMIT STS-1/STS-3 PATH - TRANSMIT G1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_G1_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit G1 Byte Value:
These READ/WRITE bit-fields are used to have software control over the contents of the RDI-P and REI-P bit-fields,
within each G1 byte in the outbound STS-1/STS-3 SPE.
NOTE:
If the users sets REI-P_Insertion_Type[1:0] and RDI-P_Insertion_Type[1:0] bits to the value [0, 1], then
contents of the REI-P and the RDI-P bit-fields (within each G1 byte of the outbound STS-1/STS-3 SPE) will be
dictated by the contents of this register. The REI-P_Insertion_Type[1:0] and RDI-P_Insertion_Type[1:0] bitfields are located in the Transmit STS-1/STS-3 Path - SONET Control Register - Byte 0 Register (Address
Location= 0x0783)
TABLE 197: TRANSMIT STS-1/STS-3 PATH - TRANSMIT F2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_F2_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit F2 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the F2 byte, within each outbound
STS-1/STS-3 SPE.
If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the F2 byte, then
it will automatically write the contents of this register into the F2 byte location, within each outbound STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT7 (F2 Byte Insertion Type) within the Transmit STS-1/STS3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0783).
149
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 198: TRANSMIT STS-1/STS-3 PATH - TRANSMIT H4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A7)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_H4_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit H4 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the H4 byte, within each outbound
STS-1/STS-3 SPE.
If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the H4 byte, then
it will automatically write the contents of this register into the H4 byte location, within each outbound STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT 0 (H4 Insertion Type) within the Transmit STS-1/STS-3
Path - SONET Control Register - Byte 1 register (Address Location= 0x07A7).
TABLE 199: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z3 BYTE VALUE REGISTER (ADDRESS LOCATION=
0X07AB)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Z3_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Z3 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the Z3 byte, within each outbound
STS-1/STS-3 SPE.If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source
of the Z3 byte, then it will automatically write the contents of this register into the Z3 byte location, within each outbound
STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT 1 (Z3 Insertion Type) within the Transmit STS-1/STS-3
Path - SONET Control Register - Byte 0 register (Address Location= 0x0782).
TABLE 200: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z4 BYTE VALUE REGISTER (ADDRESS LOCATION=
0XN9AF)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Z4_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Z4 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the Z4 byte, within each outbound
STS-1/STS-3 SPE.
If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the Z4 byte, then
it will automatically write the contents of this register into the Z4 byte location, within each outbound STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT 2 (Z4 Insertion Type) within the Transmit STS-1/STS-3
Path - SONET Control Register - Byte 0 register (Address Location= 0x0782).
150
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 201: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z5 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07B3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Z5_Byte_Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Z5 Byte Value
These READ/WRITE bit-fields are used to have software control over the value of the Z5 byte, within each outbound
STS-1/STS-3 SPE.
If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the Z5 byte, then
it will automatically write the contents of this register into the Z5 byte location, within each outbound STS-1/STS-3 SPE.
This feature is enabled whenever the user writes a 0 into BIT 3 (Z5 Insertion Type) within the Transmit STS-1/STS-3
Path - SONET Control Register - Byte 0 register (Address Location= 0x0782).
TABLE 202: TRANSMIT STS-1/STS-3 PATH - TRANSMIT PATH CONTROL REGISTER (ADDRESS LOCATION= 0X07B7)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Pointer
Force
Check Stuff
Insert Negative Stuff
InsertPositive Stuff
InsertContinuous NDF
Events
InsertSingle
NDF Event
R/O
R/O
R/W
R/W
W
W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Unused
BITt 5 - Pointer Force
This READ/WRITE bit-field is used to load the values contained within the Transmit STS-1/STS-3 POH Arbitrary H1
Pointer and Transmit STS-1/STS-3 POH Arbitrary H2 Pointer registers (Address Location= 0x07BF and 0x07C3) into
the H1 and H2 bytes (within the outbound STS-1 or STS-3 Data stream).
The actual location of the SPE will NOT be adjusted, per the value of H1 and H2 bytes. Hence, this feature should cause
the remote terminal to declare an Invalid Pointer condition.
` 0 - Configures the Transmit STS-1/STS-3 POH and TOH Processors to transmit STS-1 or STS-3 Data with normal
and correct H1 and H2 bytes.
` 1 - Configures the Transmit STS-1/STS-3 POH and TOH Processor blocks to overwrite the values of the H1 and H2
bytes (in the outbound STS-1 or STS-3 Data-stream) with the values in the Transmit STS-1/STS-3 POH Arbitrary H1
and H2 Pointer registers.
BITt 4 - Check Stuff Monitoring
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to only
execute a Positive, Negative or NDF event (via the Insert Positive Stuff, Insert Negative Stuff, Insert Continuous or
Single NDF options, via software command) if no pointer adjustment (NDF or otherwise) has occurred during the last 3
STS-1/STS-3 frame periods.
` 0 - Disables this feature.In this mode, the Transmit STS-1/STS-3 POH and TOH Processor block will execute a
software-commanded pointer adjustment event, independent of whether a pointer adjustment event has occurred in the
last 3 STS-1/STS-3 frame periods.
` 1 - Enables this feature.In this mode, the Transmit STS-1/STS-3 POH and TOH Processor block will ONLY execute
a software-commanded pointer adjustment event, if no pointer adjustment event has occurred during the last 3 STS1/STS-3 frame periods.
BITt 3 - Insert Negative Stuf
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to insert a
negative-stuff into the outbound STS-1 or STS-3 Data stream. This command, in-turn will cause a Pointer
151
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Decrementing event at the remote terminal.
` Writing a 0 to 1 transition into this bit-field causes the following to happen.
•
A negative-stuff will occur (e.g., a single payload byte will be inserted into the H3 byte position within the
outbound STS-1 or STS-3 Data stream).
•
The D bits, within the H1 and H2 bytes will be inverted (to denote a Decrementing Pointer Adjustment event).
•
The contents of the H1 and H2 bytes will be decremented by 1, and will be used as the new pointer from this
point on.
NOTE: Once the user writes a 1 into this bit-field, the XRT86SH328 will automatically clear this bit-field. Hence, there
is no need to subsequently reset this bit-field to 0.
BITt 2 - Insert Positive Stuff
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to insert a
positive-stuff into the outbound STS-1 or STS-3 Data stream. This command, in-turn will cause a Pointer Incrementing
event at the remote terminal.
` Writing a 0 to 1 transition into this bit-field causes the following to happen.
•
A positive-stuff will occur (e.g., a single stuff-byte will be inserted into the STS-1 or STS-3 Data-stream,
immediately after the H3 byte position within the outbound STS-1 or STS-3 Data stream).
•
The I bits, within the H1 and H2 bytes will be inverted (to denote a Incrementing Pointer Adjustment event).
•
The contents of the H1 and H2 bytes will be incremented by 1, and will be used as the new pointer from this
point on.Note
NOTE: Once the user writes a 1 into this bit-field, the XRT86SH328 will automatically clear this bit-field. Hence, there
is no need to subsequently reset this bit-field to 0.
BITt 1 - Insert Continuous NDF Events
This READ/WRITE bit-field is used configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to
continuously insert a New Data Flag (NDF) pointer adjustment into the outbound STS-1 or STS-3 Data stream.
As the Transmit STS-1/STS-3 POH and TOH Processor blocks insert the NDF event into the STS-1 or STS-3 Data
stream, it will proceed to load in the contents of the Transmit STS-1/STS-3 POH Arbitrary H1 Pointer and Transmit STS1/STS-3 POH Arbitrary H2 Pointer registers into the H1 and H2 bytes (within the outbound STS-1 or STS-3 Data
stream).
` 0 - Configures the Transmit STS-1/STS-3 TOH and POH Processor blocks to not continuously insert NDF events into
the outbound STS-1 or STS-3 Data stream.
` 1- Configures the Transmit STS-1/STS-3 TOH and POH Processor blocks to continuously insert NDF events into the
outbound STS-1 or STS-3 Data stream.
BITt 0 - Insert Single NDF Event
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to insert a
New Data Flag (NDF) pointer adjustment into the outbound STS-1 or STS-3 Data stream.
` Writing a 0 to 1 transition into this bit-field causes the following to happen
•
The N bits, within the H1 byte will set to the value 1001
•
The ten pointer-value bits (within the H1 and H2 bytes) will be set to new pointer value per the contents within
the Transmit STS-1/STS-3 POH - Arbitrary H1 Pointer and Transmit STS-1/STS-3 POH Arbitrary H2 Pointer
registers (Address Location= 0x07BF and 0xN9C3).
NOTE: Afterwards, the N bits will resume their normal value of 0110 and this new pointer value will be used as the new
pointer from this point on. Once the user writes a 1 into this bit-field, the XRT86SH328 will automatically clear
this bit-field. Hence, there is no need to subsequently reset this bit-field to 0.
152
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 203: TRANSMIT STS-1/STS-3 PATH - SONET PATH J1 CONTROL REGISTER (ADDRESS LOCATION=
0X07BB)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Insertion_Method[1:0]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:2] - Unused
BIT [1:0] - J1 Byte Insertion_Method[1:0]
These READ/WRITE bit-fields are used to specify the method that the user will use to insert the J1 byte into the
outbound STS-1/STS-3 SPE. The relationship between the contents of these bit-fields and the corresponding J1 Byte
Insertion Method is presented below.
Insertion Method
J1 BYTE INSERTION
METHOD[1:0]
RESULTING INSERTION METHOD
00
Insert the value 0x00
01
Not Valid
10
Insert from the Transmit SONET Path - Transmit J1 Byte Value Register (Address
Location= 0x0793)
11
Insert via the TxPOH_n input port
TABLE 204: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H1 POINTER REGISTER (ADDRESS LOCATION=
0X07BF)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
NDF Bits
BIT 2
SS Bits
BIT 1
BIT 0
H1 Pointer Value
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - NDF (New Data Flag) Bits
These READ/WRITE bit-fields are used provide the value that will be loaded into the NDF bit-field (of the H1 byte),
whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path
Control Register (Address Location= 0x07B7).
BIT [3:2] - SS Bits
These READ/WRITE bit-fields is used to provide the value that will be loaded into the SS bit-fields (of the H1 byte)
whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path
Control Register (Address Location= 0x07B7).
The SS bits have no functional value, within the H1 byte.
BIT [1:0] - H1 Pointer Value[1:0]
These two READ/WRITE bit-fields, along with the constants of the Transmit STS-1/STS-3 Path - Transmit Arbitrary H2
Pointer Register (Address Location= 0x07C3) are used to provide the contents of the Pointer Word.
These two READ/WRITE bit-fields are used to define the value of the two most significant bits within the Pointer word.
Whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path
Control Register (Address Location= 0x07B7), the values of these two bits will be loaded into the two most significant
153
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
bits within the Pointer Word.
TABLE 205: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H2 POINTER REGISTER (ADDRESS LOCATION=
0X07C3)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
H2 Pointer Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - H2 Pointer Value[1:0]
These eight READ/WRITE bit-fields, along with the constants of bits 1 and 0 within the Transmit STS-1/STS-3 Path Transmit Arbitrary H1 Pointer Register (Address Location= 0x07C3) are used to provide the contents of the Pointer
Word. These two READ/WRITE bit-fields are used to define the value of the eight least significant bits within the Pointer
word.
` Whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path
Control Register (Address Location= 0x07B7), the values of these eight bits will be loaded into the H2 byte, within the
outbound STS-1 or STS-3 Data stream.
TABLE 206: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 1 (ADDRESS
LOCATION= 0X07C6)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Tx_Pointer_High[1:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
1
0
BIT [7:2] - Unused
BIT [1:0] - Transmit Pointer Word - High[1:0]
These two READ-ONLY bits, along with the contents of the Transmit STS-1/STS-3 Path - Transmit Current Pointer Byte
Register - Byte 0 (Address Location= 0x07C7) reflect the current value of the pointer (or offset of SPE within the STS1/STS-3 frame). These two bits contain the two most significant bits within the 10-bit pointer word.
TABLE 207: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 0 (ADDRESS
LOCATION= 0X07C7)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Tx_Pointer_Low[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
1
0
1
0
BIT [7:0] - Transmit Pointer Word - Low[7:0]
These two READ-ONLY bits, along with the contents of the Transmit STS-1/STS-3 Path - Transmit Current Pointer Byte
Register - Byte 1 (Address Location= 0x07C6) reflect the current value of the pointer (or offset of SPE within the STS1/STS-3 frame). These two bits contain the eight least significant bits within the 10-bit pointer word.
154
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 208: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION= 0X07C9)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
PLM-P RDI-P Code[2:0]
BIT 0
Transmit
RDI-P upon
PLM-P
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT [3:1] - PLM-P (Path - Payload Mismatch) - RDI-P Code
These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block
will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the
corresponding Receive STS-1/STS-3 POH Processor block detects and declares a PLM-P condition. In order to enable
this feature, the user must set BIT 0 (RDI-P upon PLM-P) within this register to 1.
BIT 0 - Transmit RDI-P upon PLM-P
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically
transmit the RDI-P Code (as configured in Bits 3 through 1 - within this register) whenever the corresponding Receive
STS-1/STS-3 POH Processor block declares a PLM-P condition.
` 0 - Disables the automatic transmission of RDI-P upon detection of PLM-P.
` 1 - Enables the automatic transmission of RDI-P upon detection of PLM-P.
TABLE 209: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07CA)
BIT 7
BIT 6
BIT 5
TIM-P RDI-P Code[2:0]
BIT 4
BIT 3
Transmit
RDI-P upon
TIM -P
BIT 2
BIT 1
UNEQ-P RDI-P Code[2:0]
BIT 0
Transmit
RDI-P upon
UNEQ-P
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:5] - TIM-P (Path - Trace Identification Message Mismatch) - RDI-P Code
These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block
will transmit within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the Receive
STS-1/STS-3 POH Processor block detects and declares the TIM-P defect condition.
To enable this feature, the user must set BIT 4 (Transmit RDI-P upon TIM-P) within this register to 1.
BIT 4 - Transmit RDI-P upon TIM-P
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically
transmit the RDI-P Code (as configured in Bits 7 through 5 - within this register) whenever the corresponding Receive
STS-1/STS-3 POH Processor block declares the TIM-P defect condition.
` 0 - Disables the automatic transmission of RDI-P upon detection of TIM-P.
` 1 - Enables the automatic transmission of RDI-P upon detection of TIM-P.
BIT [3:1] - UNEQ-P (Path - Unequipped) - RDI-P Code
These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block
will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the Receive
STS-1/STS-3 POH Processor block detects and declares the UNEQ-P defect condition.
To enable this feature, the user must set BIT 0 (Transmit RDI-P upon UNEQ-P) within this register to 1.
BIT 0 - Transmit RDI-P upon UNEQ-P
155
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically
transmit the RDI-P Code (as configured in Bits 3 through 1 - within this register) whenever the corresponding Receive
STS-1/STS-3 POH Processor block declares the UNEQ-P defect condition.
` 0 - Disables the automatic transmission of RDI-P upon detection of UNEQ-P.
` 1 - Enables the automatic transmission of RDI-P upon detection of UNEQ-P.
TABLE 210: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07CB)
BIT 7
BIT 6
BIT 5
LOP-P RDI-P Code[2:0]
BIT 4
BIT 3
Transmit
RDI-P upon
LOP-P
BIT 2
BIT 1
AIS-P RDI-P Code[2:0]
BIT 0
Transmit
RDI-P upon
AIS-P
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
156
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT [7:5] - LOP-P (Path - Loss of Pointer) - RDI-P Code
These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block
will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the
corresponding Receive STS-1/STS-3 POH Processor block detects and declares a LOP-P condition.
To enable this feature, the user must set BIT 4 (RDI-P upon LOP-P) within this register to 1.
BIT 4 - Transmit RDI-P upon LOP-P
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically
transmit the RDI-P Code (as configured in Bits 7 through 5 - within this register) whenever the corresponding Receive
STS-1/STS-3 POH Processor block declares a LOP-P condition
` 0 - Disables the automatic transmission of RDI-P upon detection of LOP-P.
` 1 - Enables the automatic transmission of RDI-P upon detection of LOP-P.
BIT[3:1]AIS-P (Path - AIS) - RDI-P Code
These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block
will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the
corresponding Receive STS-1/STS-3 POH Processor block detects and declares an AIS-P condition.
To enable this feature, the user must set BIT 4 (RDI-P upon AIS-P) within this register to 1.
BIT 0 - Transmit RDI-P upon AIS-P
This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically
transmit the RDI-P Code (as configured in Bits 7 through 5 - within this register) whenever the corresponding Receive
STS-1/STS-3 POH Processor block declares a AIS-P condition.
` 0 - Disables the automatic transmission of RDI-P upon detection of AIS-P.
` 1 - Enables the automatic transmission of RDI-P upon detection of AIS-P.
TABLE 211: TRANSMIT STS-1/STS-3 PATH - SERIAL PORT CONTROL REGISTER (ADDRESS LOCATION= 0X07CF)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
TxPOH Clock Speed[4:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:4] - Unused
BIT 3:0] - TxPOHClk Output Clock Signal Speed
These READ/WRITE bit-fields are used to specify the frequency of the TxPOHClk output clock signal. The formula that
relates the contents of these register bits to the TxPOHClk frequency is presented below.
FREQ = 51.84 /[2 * (TxPOH_CLOCK_SPEED + 1)
For STS-3/STS-1/STS-3 applications, the frequency of the RxPOHClk output signal must be in the range of 2.36MHz
to 25.92MHz
TABLE 212: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE
1 (ADDRESS LOCATION= 0X07D0)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Negative_Pointer_Adjustment_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Negative Pointer Adjustment Count - MSB
This RESET-upon-READ register, along with the Transmit Negative Pointer Adjustment Count Register - Byte 0
presents a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that have occurred
157
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
(in the outbound STS-1 or STS-3 Data-stream) since the last read of this register.
NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression.
TABLE 213: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE
0 (ADDRESS LOCATION= 0X07D1)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Negative_Pointer_Adjustment_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Negative Pointer Adjustment Count - LSB
This RESET-upon-READ register, along with the Transmit Negative Pointer Adjustment Count Register - Byte 1
presents a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that have occurred
(in the outbound STS-1 or STS-3 Data-stream) since the last read of this register.
NOTE:
This register contains the LSB (Least Significant Bits) of this 16-bit expression.
TABLE 214: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE
1 (ADDRESS LOCATION= 0X07D2)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Positive_Pointer_Adjustment_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Positive Pointer Adjustment Count - MSB
This RESET-upon-READ register, along with the Transmit Positive Pointer Adjustment Count Register - Byte 0 presents
a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that have occurred (in the
outbound STS-1 or STS-3 Data-stream) since the last read of this register.
NOTE:
This register contains the MSB (Most Significant Bits) of this 16-bit expression.
TABLE 215: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE
1 (ADDRESS LOCATION= 0X07D3)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit_Positive_Pointer_Adjustment_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit Positive Pointer Adjustment Count - LSB
This RESET-upon-READ register, along with the Transmit Positive Pointer Adjustment Count Register - Byte 1 presents
a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that have occurred (in the
outbound STS-1 or STS-3 Data-stream) since the last read of this register.
NOTE:
This register contains the LSB (Least Significant Bits) of this 16-bit expression.
to here 1/12/07
2.8
Transmit TUG-3 MAPPER/VC-4 POH Processor Block Registers (SDH/TUG-3 Applications
Only)
The register map for the Transmit TU-3 Mapper/VC-4 POH Processor block is presented an discussed in detail
within the "SDH Version of the Register Map".
158
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328 device, with the Transmit TUG-3 Maper/VC-4 POH Processor block "highlighted" is presented
below in Figure _.
FIGURE 8. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK "HIGHLIGHTED"
Transmit
Transmit
TUG-3
TUG-3
Mapper/
Mapper/
VC-4
VC-4POH
POH
Processor
Processor
Block
Block
Transmit
Transmit
STM-1
STM-1
SOH
SOH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Transmit
Transmit
VC-3
VC-3POH
POH
Processor
Processor
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From TU Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
STS-1/
STS-1/
STM-0
STM-0
Telecom
Telecom
Bus
Bus
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To TU
Channels 1 - 27
Receive
Receive
TUG-3
TUG-3
Mapper/
Mapper/
VC-4
VC-4
POH
POH
Processor
Processor
Block
Block
Receive
Receive
STM-1
STM-1
SOH
SOH
Processor
Processor
Block
Block
Receive
Receive
VC-3
VC-3POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
DS1/E1
Jitter
Atten
Block
VT/TU
De-Mapper
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
For detailed on the "Transmit TUG-3 Mapper/VC-4 POH Processor Block" Registers, please see the
"XRT86SH328 28-Channel DS1/E1 Framer/LIU with DS3 MUX and TU-Mapper IC - Register Map &
Description - SDH Applications".
2.9
Global VT MAPPER BLOCK CONTROL REGISTERS
The register map for the Global VT Mapper block is presented in the Table below. Additionally, a detailed
description of each of the Global VT Mapper Control registers is presented below.
TABLE 216: GLOBAL CONTROL - VT-MAPPER BLOCK - VT MAPPER BLOCK CONTROL REGISTER (ADDRESS =
0X0C03)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Latch Count
REI-V
Enable
Unused
SONET/SDH
Loop-Back
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
159
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT [7:4] - Unused
BIT 3 - Latch Count
` A "0 to 1" transition within this bit-field commands each of the VT-De-Mapper blocks to update the contents within the
following Bit-Fields/PMON registers.
BIT FIELDS
REGISTER NAME
ADDRESS
LOCATION
VT-Payload Pointer
Increment Count[3:0]
Channel Control VT Mapper Block - Egress Direction - BIP-2
Error Count Register - Byte 1
0xND4A
BIP-2 Error Count[11:8]
Channel Control VT Mapper Block - Egress Direction - BIP-2
Error Count Register - Byte 1
0xND4A
BIP-2 Error Count[7:0]
Channel Control VT Mapper Block - Egress Direction - BIP-2
Error Count Register - Byte 0
0xND4B
VT-Payload Pointer Dec- Channel Control - VT Mapper Block - Egress Direction - REI-V
rement Count[3:0]
Event Count Register - Byte 1
0xND4E
REI-V Event Count[11:8] Channel Control - VT Mapper Block - Egress Direction - REI-V
Event Count Register - Byte 1
0xND4E
REI-V Event Count[7:0]
0xND4F
Channel Control - VT Mapper Block - Egress Direction - REI-V
Event Count Register - Byte 0
BIT 2 - REI-V Enable
This READ/WRITE bit-field is used to configure a given Transmit VT-Mapper block to automatically insert the
appropriate REI-V value (based upon the number of B2 bit errors that are detected by the corresponding Receive VTMapper block) into the V5 byte, within its outbound VT1.5 or VT2 data-stream.
` 0 - Configures the Transmit VT-Mapper block to NOT automatically insert the REI-V value into each V5 byte, within
the outbound VT data-stream.
` 1 - Configures the Transmit VT-Mapper block to automatically insert the REI-V value into each V5 byte, within the
outbound VT data-stream.
BIT 1 - Unused
BIT 0 - VT Mpper SONET/SDH Loop-Back
This READ/WRITE bit-field permits the user to configure the XRT86SH328 device to operate in the "VT Mapper
SONET/SDH Loop-back" Mode. If the user configures the XRT86SH328 device to operate in this mode, then the
outputs (from each of the 28 VT-Mapper blocks) will be internally looped back into the inputs of their corresponding VTDe-Mapper block.
Figure _ presents an illustration of the XRT86SH328 device whenever it has been configured to operate in the "VT
Mapper SONET/SDH Loop-back" Mode.
Figure _, Illustration of the Functional Block Diagram of the XRT86SH328 device with the "VT-Mapper
SONET/SDH Loop-back" path depicted.
160
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
FIGURE 9. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WITH THE VT-MAPPER
SONET/SDH LOOP-BACK PATH DEPICTED
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
VT Mapper SONET/SDH Loop-Back
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
` 0 - Does not configure the XRT86SH328 device to operate in the "VT-Mapper SONET/SDH Loop-back" Mode.
` 1 - Configures the XRT86SH328 device to operate in the "VT-Mapper SONET/SDH Loop-back" Mode.
TABLE 217: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 1 (ADDRESS =
0X0C0E)
BIT7
BIT6
BIT 5
BIT 4
Latch Error
Count
Insert Pattern Error
R/W
R/W
R/O
R/O
0
0
0
0
BIT 3
BIT 2
BIT 1
BIT 0
R/O
R/O
R/O
R/O
0
0
0
0
Reserved
BIT7 - Latch Error Count
A 0 to 1 transition within this bit-field commands the Test Pattern Receiver to latch its current Bit Error Count into Bits 6
- 0 (Test Pattern Error Count[14:8]) and BIT [7:0] (Test Pattern Error Count[7:0]) within the VT Mapper - Test Pattern
Detector Error Count Register (Address Locations = 0x0C16 and 0x0C17).
BIT6 - Insert Pattern Error
This bit-field is used to configure the VT-Mapper Test Pattern Generator block to insert a single bit-error into the
outbound VT data-stream. A 0 to 1 transition within this bit-field will command the VT-Mapper Test Pattern Generator
block to insert a single bit-error into the outbound VT data-stream.
Bits [5 - 0] - Reserved
161
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 218: GLOBAL VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0C0F)
BIT7
BIT6
BIT 5
VT1.5 Transmit Test Pattern[1:0]
BIT 4
BIT 3
VT2 Transmit Test Pattern[1:0]
BIT 2
VT3 Transmit Test Pattern[1:0]
BIT 1
BIT 0
VT6 Transmit Test Pattern[1:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 6 - VT1.5 Transmit Test Pattern[1:0]
This READ/WRITE bit-field is used to specify the test pattern that the VT1.5 Test Pattern Generator will generate and
transmit.
Transmitted Test Pattern
VT1.5 TRANSMIT TEST
PATTERN[1:0]
TEST PATTERN TRANSMITTED
00
All Zeros Pattern
01
All Ones Pattern
10
Repeating 1010… Pattern
11
2^15-1 PRBS Pattern
BIT[5:4] - VT2 Transmit Test Pattern[1:0]
This READ/WRITE bit-field is used to specify the test pattern that the VT2 Test Pattern Generator will generate and
transmit.
Transmitted Test Pattern
VT2 TRANSMIT TEST
PATTERN[1:0]
TEST PATTERN TRANSMITTED
00
All Zeros Pattern
01
All Ones Pattern
10
Repeating 1010… Pattern
11
2^15-1 PRBS Pattern
BIT[3:2] - VT3 Transmit Test Pattern[1:0]
This READ/WRITE bit-field is used to specify the test pattern that the VT3 Test Pattern Generator will generate and
transmit.
Transmitted Test Pattern
VT3 TRANSMIT TEST
PATTERN[1:0]
TEST PATTERN TRANSMITTED
00
All Zeros Pattern
01
All Ones Pattern
10
Repeating 1010… Pattern
11
2^15-1 PRBS Pattern
162
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT[1:0] - VT6 Transmit Test Pattern[1:0]
This READ/WRITE bit-field is used to specify the test pattern that the VT6 Test Pattern Generator will generate and
transmit.
Transmitted Test Pattern
VT6 TRANSMIT TEST
PATTERN[1:0]
TEST PATTERN TRANSMITTED
00
All Zeros Pattern
01
All Ones Pattern
10
Repeating 1010… Pattern
11
2^15-1 PRBS Pattern
TABLE 219: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 1 (ADDRESS =
0X0C12)
BIT7
BIT6
Test Channel Size[1:0]
BIT 5
BIT 4
Test Channel
Drop Side
SONET/SDH
BIT 3
BIT 2
BIT 1
BIT 0
Test Channel Drop Side[4:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7-6 - Test Channel Size[1:0]:
These two READ/WRITE bit-fields are used to specify the Size of the Test Channel (e.g., the Channel that will be used
to transport the user-specified Test Pattern.
Test Channel Size
TEST CHANNEL SIZE[1:0]
TEST CHANNEL SIZE
00
VT-6
01
VT-3
10
VT2/TU-12
11
VT1.5/TU-11
BIT 5 - Test Channel Drop Side SONET/SDH
This READ/WRITE bit-field is used to select the source of the Test Channel. In this case, the user can either select
either a DS1/E1 Channel originating from the Receive SONET/SDH Block or a DS1/E1 Channel originating from the
Ingress Direction DS1/E1 Blocks.
` 0 - Configures the Test Channel Source to be one of the DS1/E1 Channels, originating from the Ingress Direction
DS1/E1 Blocks.
` 1 - Configures the Test Channel Source to be the DS1/E1 Channels, originating from the Receive SONET/SDH
Blocks
BIT[4:0] - Test Channel Drop Side[4:0]
These READ/WRITE bit-fields are used to select which data-stream will be output via the Test Channel.
163
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Output Data Stream via Test Channel
TEST CHANNEL DROP SIDE[4:0]
TEST CHANNEL USED
00000
Do Not Use
00001
DS1/E1 Channel 1
00010
DS1/E1 Channel 2
00011
DS1/E1 Channel 3
00100
DS1/E1 Channel 4
00101
DS1/E1 Channel 5
00110
DS1/E1 Channel 6
00111
DS1/E1 Channel 7
01000
DS1/E1 Channel 8
01001
DS1/E1 Channel 9
01010
DS1/E1 Channel 10
01011
DS1/E1 Channel 11
01100
DS1/E1 Channel 12
01101
DS1/E1 Channel 13
01110
DS1/E1 Channel 14
01111
DS1/E1 Channel 15
10000
DS1/E1 Channel 16
10001
DS1/E1 Channel 17
10010
DS1/E1 Channel 18
10011
DS1/E1 Channel 19
10100
DS1/E1 Channel 20
10101
DS1/E1 Channel 21
10110
DS1/E1 Channel 22
10111
DS1/E1 Channel 23
11000
DS1/E1 Channel 24
11001
DS1/E1 Channel 25
11010
DS1/E1 Channel 26
11011
DS1/E1 Channel 27
11100
DS1/E1 Channel 28
11101
AIS will be Generated
11110
Test Channel Input
11111
User Selected Test Pattern
164
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 220: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 0 (ADDRESS =
0X0C13)
BIT7
BIT6
BIT 5
Receive (Expected) Pattern[1:0]
BIT 4
BIT 3
Test Channel
Drop Side SONET/SDH
BIT 2
BIT 1
BIT 0
Test Channel Drop Side[4:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 6 - Receive (Expected) Pattern:
This READ/WRITE bit-field is used to specify the Test Pattern, that the VT-Mapper Pattern Receiver should be
expecting, as shown in the table below.
Expected Test Pattern
RECEIVE (EXPECTED)
PATTERN[1:0]
EXPECTED TEST PATTERN
00
All Zeros Pattern
01
All Ones Pattern
10
Repeating 1010… Pattern
11
2^15-1 PRBS Pattern
BIT 5 - Test Channel Drop-Side SONET/SDH
This READ/WRITE bit-field is used to select which set of DS1/E1 traffic should be used, as a basis of comparison
against the Test Signal. In this case, the user can either select the either the DS1/E1 traffic originating from the Ingress
Direction DS1/E1 Blocks or the DS1/E1 traffic originating from the Receive SONET/SDH Blocks.
` 0 - Configures the Pattern Receiver to compare the Test Signal with one of the DS1/E1 Channels, originating from
the Ingress Direction DS1/E1 Blocks.
` 1 - Configures the Pattern Receiver to compare the Test Signal with one of the DS1/E1 Channels, originating from
the Receive SONET/SDH Blocks.
BIT[4:0] - Test Channel Drop Side[4:0]:
These READ/WRITE bit-fields are used to select which data-stream will be compared with the Test Signal.
Test Channel Selection
TEST CHANNEL DROP SIDE[4:0]
TEST CHANNEL USED
00000
Do Not Use
00001
DS1/E1 Channel 1
00010
DS1/E1 Channel 2
00011
DS1/E1 Channel 3
00100
DS1/E1 Channel 4
00101
DS1/E1 Channel 5
00110
DS1/E1 Channel 6
00111
DS1/E1 Channel 7
165
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Test Channel Selection
TEST CHANNEL DROP SIDE[4:0]
TEST CHANNEL USED
01000
DS1/E1 Channel 8
01001
DS1/E1 Channel 9
01010
DS1/E1 Channel 10
01011
DS1/E1 Channel 11
01100
DS1/E1 Channel 12
01101
DS1/E1 Channel 13
01110
DS1/E1 Channel 14
01111
DS1/E1 Channel 15
10000
DS1/E1 Channel 16
10001
DS1/E1 Channel 17
10010
DS1/E1 Channel 18
10011
DS1/E1 Channel 19
10100
DS1/E1 Channel 20
10101
DS1/E1 Channel 21
10110
DS1/E1 Channel 22
10111
DS1/E1 Channel 23
11000
DS1/E1 Channel 24
11001
DS1/E1 Channel 25
11010
DS1/E1 Channel 26
11011
DS1/E1 Channel 27
11100
DS1/E1 Channel 28
11101
AIS will be Generated
11110
Test Channel Input
11111
Disable Pattern Receiver
TABLE 221: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - UPPER BYTE
(ADDRESS = 0X0C16)
BIT7
BIT6
BIT 5
VT-Mapper
Test Pattern
Sync
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Test Pattern Error Count[14:8]
R/O
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT7 - VT-Mapper Test Pattern Sync:
166
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This READ-ONLY bit-field indicates whether or not the VT-Mapper Pattern Receiver is currently declaring Pattern Sync
with the incoming Test Signal.
` 0 - VT-Mapper Pattern Receiver is NOT currently declaring Pattern Sync with the incoming Test Signal.
` 1 - VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the incoming Test Signal.
BIT[6:0] - Test Pattern Error Count[14:8]:
These seven (7) RESET-upon-READ bit-fields, along with the Test Pattern Error Count[7:0] bit-fields function as a 15bit Pattern Bit Error Count Register. If the VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the
designated Test Signal, then it will increment this register (by the value of 1) each time that it detects Pattern Bit Error.
These seven (7) bit-fields function as the seven most-significant bits of this 15-bit counter.
TABLE 222: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - LOWER BYTE
(ADDRESS = 0X0C17)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Test Pattern Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT[7:0] - Test Pattern Error Count[7:0]:
These eight (8) RESET-upon-READ bit-fields, along with the Test Pattern Error Count[14:8] bit-fields function as a 15bit Pattern Bit Error Count Register. If the VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the
designated Test Signal, then it will increment this register (by the value of 1) each time that it detects Pattern Bit Error.
These eight (8) bit-fields function as the eight least-significant bits of this 15-bit counter.
TABLE 223: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS =
0X0C1A)
BIT7
BIT6
Unused
BIT 5
BIT 4
BIT 3
TxTributary Size Select VT#6[1:0]
BIT 2
TxTributary Size Select VT#5[1:0]
BIT 1
BIT 0
TxTributary Size Select VT#4[1:0]
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
1
1
1
1
1
1
Bits 7 - 6 - Unused:
BIT[5:4] - Transmit Tributary Size Select for VT# 6[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper block (associated with Virtual Tributary Group # 6) will support.
Size of VT #6
TXTRIBUTARY SIZE
SELECT - VT#6[1:0]
RESULTING SIZE OF VT # 6
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
NOTE: This configuration setting only applies to the Transmit VT-Mapper block. This configuration setting does not
configure the Receive VT-De-Mapper block to expect any particular VT-type within VT Group # 6. The user
167
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
must separately configure the Receive VT-De-Mapper block's handling of VT-Group # 6 by setting Bits 4 and 5
(RxTributary Size Select - VT# 6[1:0]) within the VT-Mapper - Receive Tributary Size Select Register (Address =
0x0C1E).
BIT[3:2] - Transmit Tributary Size Select for VT# 5[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper block (associated with Virtual Tributary Group # 5) will support.
Size of VT #5
TXTRIBUTARY SIZE
SELECT - VT#5[1:0]
RESULTING SIZE OF VT # 5
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[1:0] - Transmit Tributary Size Select for VT# 4[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper block (associated with Virtual Tributary Group # 4), will support.
Size of VT #4
TXTRIBUTARY SIZE SELECT
- VT#4[1:0]
RESULTING SIZE OF VT # 4
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
TABLE 224: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS =
0X0C1B)
BIT7
BIT6
TxTributary Size Select VT#3[1:0]
BIT 5
BIT 4
BIT 3
TxTributary Size Select VT#2[1:0]
BIT 2
TxTributary Size Select VT#1[1:0]
BIT 1
BIT 0
TxTributary Size Select VT#0[1:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
Bits 7 - 6 - Transmit Tributary Size Select for VT# 3[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper block (associated with Virtual Tributary Group # 3), will support.
TxTributary Size Select of VT#3
TXTRIBUTARY SIZE SELECT
- VT#3[1:0]
RESULTING SIZE OF VT # 3
00
VT-6
01
VT-3
168
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TxTributary Size Select of VT#3
TXTRIBUTARY SIZE SELECT
- VT#3[1:0]
RESULTING SIZE OF VT # 3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[5:4] - Transmit Tributary Size Select for VT# 2[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper block (associated with Virtual Tributary Group # 2) will support.
TxTributary Size Select of VT#2
TXTRIBUTARY SIZE
SELECT - VT#2[1:0]
RESULTING SIZE OF VT # 2
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[3:2] - Transmit Tributary Size Select for VT# 1[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper block (associated with Virtual Tributary Group # 1) will support.
TxTributary Size Select of VT#1
TXTRIBUTARY SIZE
SELECT - VT#1[1:0]
RESULTING SIZE OF VT # 1
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[1:0] - Transmit Tributary Size Select for VT# 0[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit
VT-Mapper Block (associated with Virtual Tributary Group # 0) will support.
TxTributary Size Select of VT#0
TXTRIBUTARY SIZE
SELECT - VT#0[1:0]
RESULTING SIZE OF VT # 0
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
169
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 225: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1E)
BIT7
BIT6
Unused
BIT 5
BIT 4
BIT 3
RxTributary Size Select VT#6[1:0]
BIT 2
RxTributary Size Select VT#5[1:0]
BIT 1
BIT 0
RxTributary Size Select VT#4[1:0]
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
1
1
1
1
1
1
Bits 7 - 6 - Unused:
BIT[5:4] - Receive Tributary Size Select for VT# 6[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper Block (associated with Virtual Tributary Group # 6) will support.
Resulting Size of VT#6
RXTRIBUTARY SIZE
SELECT - VT#6[1:0]
RESULTING SIZE OF VT # 6
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[3:2] - Receive Tributary Size Select for VT# 5[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper block (associated with Virtual Tributary Group # 5) will support.
Resulting Size of VT#5
RXTRIBUTARY SIZE
SELECT - VT#5[1:0]
RESULTING SIZE OF VT # 5
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[1:0] - Receive Tributary Size Select for VT# 4[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper block (associated with Virtual Tributary Group # 4) will support.
Resulting Size of VT#4
RXTRIBUTARY SIZE
SELECT - VT#4[1:0]
RESULTING SIZE OF VT # 4
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
170
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 226: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1F)
BIT7
BIT6
RxTributary Size Select VT#3[1:0]
BIT 5
BIT 4
BIT 3
RxTributary Size Select VT#2[1:0]
BIT 2
RxTributary Size Select VT#1[1:0]
BIT 1
BIT 0
RxTributary Size Select VT#0[1:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
1
1
1
1
1
1
BIT[7:6] - Receive Tributary Size Select for VT# 3[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper block (associated with Virtual Tributary Group # 3) will support.
Resulting Size of VT#3
RXTRIBUTARY SIZE
SELECT - VT#3[1:0]
RESULTING SIZE OF VT # 3
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[5:4] - Receive Tributary Size Select for VT# 2[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper block (associated with Virtual Tributary Group # 2) will support.
Resulting Size of VT#2
RXTRIBUTARY SIZE
SELECT - VT#2[1:0]
RESULTING SIZE OF VT # 2
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
BIT[3:2] - Receive Tributary Size Select for VT# 1[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper block (associated with Virtual Tributary Group # 1) will support.
Resulting Size of VT#1
RXTRIBUTARY SIZE SELECT
- VT#1[1:0]
RESULTING SIZE OF VT # 1
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
171
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT[1:0] - Receive Tributary Size Select for VT# 0[1:0]:
These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive
VT-Mapper block (associated with Virtual Tributary Group # 0) will support.
Resulting Size of VT#0
RXTRIBUTARY SIZE SELECT
- VT#0[1:0]
2.10
RESULTING SIZE OF VT # 0
00
VT-6
01
VT-3
10
VT-2/TU-12
11
VT-1.5/TU-11
DS3 MAPPER CONTROL REGISTERS
TABLE 227: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D02)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
Default_R
Default_O
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
1
1
BIT[7:0] - Reserved
BIT 1 - Default_R Value:
When a DS3 signal is mapped into an STS-1/STS-3 SPE or a VC-3, there are numerous bits that are also stuffed into
the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency differences between DS3 and an STS1/STS-3 SPE or an SDH VC-3.
One such bit is referred to as an R bit. Currently, the standards do not define a use for these bits. Hence, this bit can
be used as a proprietary communication link between two pieces of equipment.
This READ/WRITE bit-field is used to set the value for the R bits in the outbound STS-1/STS-3 SPE or SDH VC-3.
NOTES:
1. The XRT86SH328 includes a corresponding READ-ONLY register bit, in which one can obtain the value
for the R bits in the incoming STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 1 (Received
R) within the DS3 Mapper Block - Receive Status Register - Byte 1 (Address = 0x0D06).
2. This register bit is only active if the XRT86SH328 has been configured to operate in the M13 MUX which
is Asynchronously mapped into STS-1/STS-3 Mode.
BIT 0 - Default_O Value:
When a DS3 signal is mapped into a STS-1/STS-3 SPE (in SONET) or a VC-3 (in SDH), there are numerous bits that
are also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency differences between
DS3 and an STS-1/STS-3 SPE or an SDH VC-3.
One such bit is referred to as an 0 bit. Currently, the standards do not define a use for these bits. Hence, this bit can
be used as a proprietary communication link between two pieces of equipment.
This READ/WRITE bit-field is used to set the value for the O bits in the outbound STS-1/STS-3 SPE or SDH VC-3.
NOTES:
1. The XRT86SH328 includes a corresponding READ-ONLY register bit in which one can obtain the value
for the O bits in the incoming STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 0 (Received
O) within the DS3 Mapper Block - Receive Status Register - Byte 1 (Address = 0x0D06).
2. This register bit is only active if the XRT86SH328 has been configured to operate in the M13 MUX
Asynchronously Mapped into STS-1/STS-3 Mode.
172
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 228: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D03)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Gap Clock in
Egress T1/E1
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/W
0
0
0
0
0
0
0
0
BIT[7:1] - Reserved
BIT 0 - Gap Clock in Egress T1/E1
This READ/WRITE bit-field permits the user to apply some "clock-smoothing" to the Egress Direction T1/E1 signals prior
to being routed to the Transmit DS1/E1 LIU Block, as depicted below.
` 0 - Configures the chip to perform "clock-smoothing" on all Egress Direction T1/E1 signals prior to being routed to the
Transmit DS1/E1 LIU Blocks.
` 1- Disables this "clock-smoothing" feature.
TABLE 229: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D06)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
Received_R
Received_O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
1
1
BIT[7:2] - Reserved:
BIT 1 - Received_R:
When a DS3 signal is de-mapped from an STS-1/STS-3 SPE (in SONET) or a VC-3 (in SDH), there are numerous bits
that were also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency differences
between DS3 and an STS-1/STS-3 SPE or an SDH VC-3.
One such bit is referred to as an R bit. Currently, the standards do not define a use for these bits. Hence, this bit can
be used as a proprietary communication link between two pieces of equipment.
This READ-ONLY bit-field contains the value of the R bits within the most recently received STS-1/STS-3 SPE or SDH
VC-3.
NOTE: The XRT86SH328 includes a corresponding READ/WRITE register bit, in which one can set the value for the R
bits, in the outbound STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 1 (Default_R) within the
DS3 Mapper Block - Control Register - Byte 1 (Address = 0x0D02).
BIT 0 - Received_O:
When a DS3 signal is de-mapped from an STS-1/STS-3 SPE (in SONET) or a VC-3 (in SDH), there are numerous bits
that were also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency difference
between DS3 and an STS-1/STS-3 SPE or an SDH VC-3.
One such bit is referred to as an O bit. Currently, the standards do not define a use for these bits. Hence, this bit can
be used as a proprietary communication link between two pieces of equipment.
This READ-ONLY bit-field contains the value of the O bits within the most recently received STS-1/STS-3 SPE or SDH
VC-3.
NOTE: The XRT86SH328 includes a corresponding READ/WRITE register bit, in which one can set the value for the R
bits, in the outbound STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 1 (Default R) within the
DS3 Mapper Block - Control Register - Byte 1 (Address = 0x0D02).
173
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 230: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D07)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
Receive
FIFO Overrun
Receive
FIFO Underrun
Transmit
FIFO Overrun
Transmit
FIFO Underrun
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT[7:4] - Reserved:
BIT 3 - Receive FIFO Overrun
This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring a Receive FIFO Overrun
condition.
A Receive FIFO Overrun condition will only occur if DS3 data is output from the DS3 Mapper block to the Receive DS3
Framer block at a much faster rate than that which the Receive DS3 Framer block handles and processes the incoming
DS3 data-stream.
` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Receive FIFO Overrun condition.
` 1 - Indicates that the DS3 Mapper Block is currently declaring the Receive FIFO Overrun condition.
BIT 2 - Receive FIFO Underrun
This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring the Receive FIFO
Underrun condition.
A Receive FIFO Underrun condition will only occur if DS3 data is output from the DS3 Mapper block to the Receive DS3
Framer block at a much slower rate than that which the Receive DS3 Framer block handles and processes the incoming
DS3 data-stream.
` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Receive FIFO Underrun condition.
` 1 - Indicates that the DS3 Mapper Block is currently declaring the Receive FIFO Underrun condition.
BIT 1 - Transmit FIFO Overrun
This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring a Transmit FIFO
Overrun condition.
A Transmit FIFO Overrun condition will occur if DS3 data is output from the Transmit DS3 Framer block (towards the
DS3 Mapper Block) at a much faster rate than which the DS3 Mapper block handles and processes the outbound DS3
data-stream.
` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Transmit FIFO Overrun condition.
` 1 - Indicates that the DS3 Mapper Block is currently declaring the Transmit FIFO Overrun condition.
BIT 0 - Transmit FIFO Underrun
This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring a Transmit FIFO
Underrun condition.
A Transmit FIFO Underrun condition will occur if DS3 data is output from the Transmit DS3 Framer block (towards the
DS3 Mapper Block) at a much slower rate than that which the DS3 Mapper Block handles and processes the outbound
DS3 data-stream.
` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Transmit FIFO Underrun condition.
` 1 - Indicates that the DS3 Mapper Block is currently declaring the Transmit FIFO Underrun condition.
174
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 231: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS =
0X0D0B)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
Receive
FIFO Overrun Interrupt
Status
Receive
FIFO Underrun Interrupt
Status
Transmit
FIFO Overrun Interrupt
Status
Transmit
FIFO Underrun Interrupt
Status
R/O
R/O
R/O
R/O
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT[7:4] - Reserved
BIT 3 - Receive FIFO Overrun Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Receive FIFO Overrun interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the DS3 Mapper block will generate this interrupt anytime it declares a Receive FIFO
Overrun condition.
` 0 - Indicates that the Receive FIFO Overrun interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Receive FIFO Overrun interrupt has occurred since the last read of this register.
NOTE: The user can obtain the current status of the Receive FIFO Overrun condition by reading the state of BIT 3
(Receive FIFO Overrun Condition) within the DS3 Mapper - Status Register - Byte 0 (Address = 0x0D07).
BIT 2 - Receive FIFO Underrun Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Receive FIFO Underrun interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the DS3 Mapper Block will generate this interrupt anytime it declares a Receive FIFO
Underrun condition.
` 0 - Indicates that the Receive FIFO Underrun interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Receive FIFO Underrun interrupt has occurred since the last read of this register.
NOTE: The user can obtain the current status of the Receive FIFO Underrun condition by reading the state of BIT 2
(Receive FIFO Underrun Condition) within the DS3 Mapper - Status Register - Byte 0 (Address = 0x0D07).
BIT 1 - Transmit FIFO Overrun Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Transmit FIFO Overrun interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the DS3 Mapper block will generate this interrupt anytime it declares a Transmit FIFO
Overrun condition.
` 0 - Indicates that the Transmit FIFO Overrun Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Transmit FIFO Overrun Interrupt has occurred since the last read of this register.
NOTE: The user can determine the current status of the Transmit FIFO Overrun condition by reading the state of BIT 1
(Transmit FIFO Overrun Condition) within the DS3 Mapper Block - Status Register - Byte 0 (Address =
0x0D07).
BIT 0 - Transmit FIFO Underrun Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the Transmit FIFO Underrun interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the DS3 Mapper block will generate this interrupt anytime it declares a Transmit FIFO
Underrun condition.
` 0 - Indicates that the Transmit FIFO Underrun interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Transmit FIFO Underrun interrupt has occurred since the last read of this register.
175
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
NOTE: The user can determine the current state of the Transmit FIFO Underrun condition by reading the state of BIT 0
(Transmit FIFO Underrun Condition) within the DS3 Mapper Block - Status Register - Byte 0 (Address =
0x0D07).
TABLE 232: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS =
0X0D0E)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
Receive
FIFO Overrun Interrupt
Enable
Receive
FIFO Underrun Interrupt
Enable
Transmit
FIFO Overrun Interrupt
Enable
Transmit
FIFO Underrun Interrupt
Enable
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT[7:4] - Reserved:
BIT 3 - Receive FIFO Overrun Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Receive FIFO Overrun Interrupt.
If this interrupt is enabled, then the DS3 Mapper block will generate an interrupt anytime it declares the Receive FIFO
Overrun condition.
` 0 - Disables this interrupt.
` 1 - Enables this interrupt.
BIT 2 - Receive FIFO Underrun Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the 'Receive FIFO Underrun interrupt.
If this interrupt is enabled, then the DS3 Mapper Block will generate an interrupt anytime it declares the Receive FIFO
Underrun condition.
` 0 - Disables this interrupt.
` 1 - Enables this interrupt.
BIT 1 - Transmit FIFO Overrun Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Transmit FIFO Overrun interrupt.
If this interrupt is enabled, then the DS3 Mapper block will generate an interrupt anytime it declares the Transmit FIFO
Overrun condition.
` 0 - Disables this interrupt.
` 1 - Enables this interrupt.
BIT 0 - Transmit FIFO Underrun Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Transmit FIFO Underrun interrupt.
If this interrupt is enabled, then the DS3 Mapper block will generate an interrupt anytime that the DS3 Mapper block
declares the Transmit FIFO Underrun condition.
` 0 - Disables this interrupt.
` 1 - Enables this interrupt.
TABLE 233: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 2 (ADDRESS = 0X0D21)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
PStuff
BIT 2
BIT 1
BIT 0
Unused
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT7 - Pstuff:
176
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT[6:0] - Unused:
TABLE 234: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 1 (ADDRESS = 0X0D22)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TABLE 235: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D23)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TABLE 236: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 1 (ADDRESS =
0X0D26)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TABLE 237: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 0 (ADDRESS =
0X0D27)
BIT7
2.11
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS3 Framer and M13 MUX Block Registers
The register map for the DS3 Framer and M13 MUX block is presented in the Tables below. Additionally, a
detailed description of each of the DS3 Framer and M13 MUX Block registers is presented below.
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328, with the various functions that are controlled/monitored via the DS3 Framer and M13 MUX
Block Register highlighted is presented below in Figure 10.
177
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
FIGURE 10. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE FUNCTIONAL
BLOCKS (WHICH ARE CONTROLLED/MONITORED VIA THE DS3 FRAMER AND M13 MUX BLOCK REGISTERS) HIGHLIGHTED.
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
NOTE: These functional blocks are only active if the XRT86SH328 has been configured to operate in either the M13 MUX
or in the M13 MUX, which is Asynchronously Mapped into STS-1/STS-3 Mode.
TABLE 238: DS3 FRAMER BLOCK OPERATING MODE REGISTER (ADDRESS = 0X0E00)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS3 Framer
Local LoopBack
Set DS3
Mode
Internal LOS
Enable
DS3 Framer
Block Software RESET
Reserved
Frame
Format
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/W
0
1
1
0
0
0
1
1
TimRefSel[1:0]
BIT7 - DS3 Framer Local Loop-back Mode:
This READ/WRITE bit-field is used to configure the DS3/E3 Framer block to operate in the DS3 Framer block to operate
in the DS3 Framer Local Loop-back Mode. If the DS3 Framer block has been configured to operate in the Framer Local
Loop-back Mode, then the output of the Transmit DS3 Framer block will be internally looped-back into the Receive DS3
Framer block.
` 0 - Configures the DS3/E3 Framer block to operate in the Normal Operation (e.g., Non-DS3 Framer Local Loop-back)
mode
` 1 - Configures the DS3/E3 Framer block to operate in the DS3 Framer Local Loop-back Mode.
178
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT6 - Set DS3 Mode
To use the Transmit and Receive DS3 Framer blocks, within the XRT86SH328, then the user MUST set this bit-field to
1.
BIT 5 - Internal LOS Enable
This READ/WRITE bit-field is used to enable or disable the Internal LOS Detector within the Receive DS3 Framer block.
If the user enables the Internal LOS Detector, then the Receive DS3 Framer block will be configured to check the
incoming DS3 signal for a sufficient number of consecutive all zero bits and it will declare and clear the LOS defect
condition based upon the 1s density and the number of consecutive 0bits within the incoming DS3 data-stream.
If the user disables the Internal LOS Detector, then the Receive DS3 Framer block will NOT be configured to check the
incoming DS3 data-stream for a sufficient number of consecutive 0 bits, and it will NOT declare nor clear the LOS defect
condition based upon the 1s density and the number of consecutive 0 bits within the incoming DS3 data-stream.
` 0 - Disables the Internal LOS Detector
` 1 - Enables the Internal LOS Detector.
BIT 4 - DS3 Framer Block Software RESET
This READ/WRITE bit-field is used to execute a Software RESET to the Transmit and Receive DS3 Framer block. If
the user executes this Software RESET, then the contents of the Transmit/Receive DS3 Framer block configuration
registers will not be reset to their default values. Instead, internal state machines (within the Transmit and Receive DS3
Framer blocks) will be reset.
` A 0 to 1 transition in this bit-field commands a Software RESET to Transmit and Receive DS3 Framer block.
BIT 3 - Reserved
BIT 2 - Frame Format
This READ/WRITE bit-field is used to configure the Transmit and Receive DS3 Framer blocks to operate in
either the C-Bit Parity or the M13/M23 Framing formats.
` 0 - Configures the Transmit and Receive DS3 Framer blocks to operate in the C-bit Parity Framing format.
` 1 - Configures the Transmit and Receive DS3 Framer blocks to operate in the M13/M23 Framing format.
BIT[1:0] - Transmit DS3 Framer Block Timing Reference Select[1:0]
The user should set these bit-fields to either [1, 0] or [1, 1] for proper operation.
TABLE 239: DS3 FRAMER BLOCK - I/O CONTROL REGISTER (ADDRESS = 0X0E01)
BIT7
BIT6
BIT 5
BIT 4
Disable
TxLOC
LOC
Disable
RxLOC
R/W
R/O
R/W
R/O
1
0
1
0
BIT 3
BIT 2
BIT 1
BIT 0
Transmit
Line Clock
Invert
Receive Line
Clock Invert
Reframe
R/O
R/W
R/W
R/W
0
0
0
0
Unused
BIT7 - Disable Transmit Loss of Clock Feature
This READ/WRITE bit-field is used to either enable or disable the Transmit Loss of Clock feature.
If this feature is enabled, then the DS3 Framer block will enable some circuitry that will terminate the current READ or
WRITE access (to the Microprocessor Interface), if a Loss of Transmit Clock Event were to occur.
The intent behind this feature is to prevent any READ/WRITE accesses (to the DS3 Framer blocks) from hanging in the
event of a Loss of Clock event.
` 0 - Enables the Transmit Loss of Clock feature.
` 1 - Disables the Transmit Loss of Clock feature
BIT6 - LOC
BIT 5 - Disable Receive Loss of Clock Feature
This READ/WRITE bit-field is used to either enable or disable the Receive Loss of Clock feature.
If this feature is enabled, then the DS3 Framer block will enable some circuitry that will terminate the current READ or
179
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
WRITE access (to the Microprocessor Interface), if a Loss of Receive Clock Event were to occur.
The intent behind this feature is to prevent any READ/WRITE accesses (to the DS3 Framer blocks) from hanging in the
event of a Loss of Clock event.
` 0 - Enables the Receive Loss of Clock feature.
` 1 - Disables the Receive Loss of Clock feature
Bits 4 -3 - Unused
BIT 2 - Transmit Line Clock Invert
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to update the TxDS3POS and
TxDS3NEG output pins upon either the rising or falling edge of TxDS3LineClk.
` 0 - Configures the Transmit DS3 Framer block to update the TxDS3POS/TxDS3NEG upon the rising edge of the
TxDS3LineClk. The user should insure that the LIU IC will sample TxDS3POS/TxDS3NEG upon the falling edge of
TxDS3LineClk.
` 1 - Configures the Transmit DS3 Framer block to update the TxDS3POS/TxDS3NEG upon the falling edge of the
TxDS3LineClk. The user should insure that the LIU IC will sample TxDS3POS/TxDS3NEG upon the rising edge of
TxDS3LineClk.
BIT 1 - Receive Line Clock Invert
This READ/WRITE bit-field is used to configure Receive DS3 Framer block to sample and latch the
RxDS3POS/RxDS3NEG input pins upon either the rising or falling edge of RxDS3LineClk.
` 0 - Configures the Receive DS3 Framer block to sample the RxDS3POS/RxDS3NEG input pins upon the falling edge
of the RxDS3LineClk input signal.
` 1 - Configures the Receive DS3 Framer block to sample the RxDS3POS/RxDS3NEG input pins upon the rising edge
of the RxDS3LineClk input signal.
BIT 0 - Receive DS3 Framer Block - Reframe Command
A 0 to 1 transition, within this bit-field commands the Receive DS3 Framer block to exit the Frame Maintenance Mode,
and go back and enter the Frame Acquisition Mode.
NOTE: The user should go back and set this bit-field to 0 following execute of the Reframe Command.
TABLE 240: DS3 FRAMER BLOCK - BLOCK INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E04)
BIT 7
BIT 6
Receive DS3
Framer
Block
Interrupt
Enable
BIT 5
Unused
BIT 4
BIT 3
M13 MUX
Block Interrupt Enable
BIT 2
Unused
BIT 1
BIT 0
Transmit
DS3 Framer
Block
Interrupt
Enable
One Second
Interrupt
Enable
R/W
R/O
R/O
R/W
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
Bit 7 - Receive DS3 Framer Bock Interrupt Enable:
This READ/WRITE bit-field is used to enable or disable the Receive DS3 Framer Block for Interrupt Generation. If the
user enables the Receive DS3 Framer block (for Interrupt Generation) at the block level, the user still needs to enable
the interrupts at the Source Level, as well, in order for these interrupt to be enabled.
However, if the user disables the Receive DS3 Framer block (for Interrupt Generation) at the Block Level, then ALL
Receive DS3 Framer-related blocks are disabled.
` 0 - Disables all Receive DS3 Framer blocks interrupts.
` 1 - Enables the Receive DS3 Framer block for Interrupt Generation (at the Block Level)
Bits 6 - 5 - Unused:
Bit 4 - M13 MUX Block Interrupt Enable:
This READ/WRITE bit-field is used to enable or disable the M13 MUX block for Interrupt Generation. If the user enables
180
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
the M13 MUX block (for Interrupt Generation) at the block level, the user still needs to enable the interrupts at the Source
level as well, in order for these interrupts to be enabled.
However, if the user disables the M13 MX block (for Interrupt Generation) at the Block Level, then ALL M13 MUX blockrelated interrupts are disabled.
` 0 - Disables all M13 MUX block-related interrupts.
` 1 - Enables all M13 MUX block-related interrupts.
Bits 3 - 2 - Unused
Bit 1 - Transmit DS3 Framer Block Interrupt Enable:
This READ/WRITE bit-field is used to enable or disable the Transmit DS3 Framer block for Interrupt Generation. If the
user enables the Transmit DS3 Framer block (for Interrupt Generation) at the block level, the user still needs to enable
the interrupts at the Source level as well, in order for these interrupts to be enabled.
However, if the user disables the Transmit DS3 Framer block (for Interrupt Generation) at the Block Level, then ALL
Transmit DS3 Framer block-related interrupts are disabled.
` 0 - Disables all Transmit DS3 Framer block-related Interrupts.
` 1 - Enables the Transmit DS3 Framer block for Interrupt Generation (at the Block Level).
Bit 0 - One Second Interrupt Enable:
This READ/WRITE bit-field is used to enable or disable the One-Second Interrupt within the DS3/E3 Framer block. If
the user enables this interrupt, then the DS3/E3 Framer block will generate an interrupt at one second intervals.
0 - Disables the One Second Interrupt
1 - Enables the One Second Interrupt.
TABLE 241: DS3 FRAMER BLOCK - BLOCK INTERRUPT STATUS REGISTER (ADDRESS = 0X0E05)
BIT 7
BIT 6
Receive DS3
Framer
Block
Interrupt
Status
BIT 5
Unused
BIT 4
BIT 3
M13 MUX
Block
Interrupt
Status
BIT 2
Unused
BIT 1
BIT 0
Transmit
DS3 Framer
Block
Interrupt
Status
One Second
Interrupt
Status
RUR
R/O
R/O
RUR
R/O
R/O
RUR
RUR
0
0
0
0
0
0
0
0
Bit 7 - Receive DS3 Framer Bock Interrupt Status:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is requesting interrupt service.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently requesting interrupt service.
` 1 - Indicates that the Receive DS3 Framer block is currently requesting interrupt service.
Bits 6 - 5 - Unused:
Bit 4 - M13 MUX Block Interrupt Status:
This READ-ONLY bit-field indicates whether or not the M13 MUX block is requesting interrupt service.
` 0 - Indicates that the M13 MUX block is NOT currently requesting interrupt service.
` 1 - Indicates that the M13 MUX block is currently requesting interrupt service.
Bits 3 - 2 - Unused
Bit 1 - Transmit DS3 Framer Block Interrupt Status:
This READ-ONLY bit-field indicates whether or not the Transmit DS3 Framer block is requesting interrupt service.
` 0 - Indicates that the Transmit DS3 Framer block is NOT currently requesting interrupt service.
` 1 - Indicates that the Transmit DS3 Framer block is currently requesting interrupt service.
Bit 0 - One Second Interrupt Status:
181
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This RESET-upon-READ bit-field indicates whether or not a One Second interrupt has occurred since the last read of
this register.
` 0 - Indicates that the One Second Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the One Second Interrupt has occurred since the last read of this register.
TABLE 242: DS3 FRAMER BLOCK - M23 CONFIGURATION REGISTER (ADDRESS = 0X0E07)
BIT7
BIT6
BIT 5
BIT 4
Must Set to 0
BIT 3
BIT 2
M13 Local
Loop-back
Mode
Reserved
BIT 1
BIT 0
M23 Loop-Back Codes[1:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT[7:4] - Must Set to 0:
Each of these READ/WRITE bit-fields MUST be set to 0 for proper operation.
BIT 3 - M13 Local Loop-back Mode
This READ/WRITE bit-field is used to configure the XRT86SH328 to operate in the M13 Local Loop-Back Mode. If the
user configures the XRT86SH328 to operate in the M23 Local Loop-back Mode, then the output of the M23 MUX Block
will be internally routed to the input of the M13 DEMUX Block.
` 0 - Configures the XRT86SH328 to operate in the Normal Mode
` 1 - Configures the XRT86SH328 to operate in the M13 Local Loop-back Mode
Figure 11 presents an illustration of the XRT86SH328, whenever it has been configured to operate in the M13
Local Loop-back Mode.
182
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
FIGURE 11. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS
BEEN CONFIGURED TO OPERATE IN THE M13 LOCAL LOOP- BACK MODE
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
M23
M23
MUX
MUX
Block
Block
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
M12
De-MUX
Block
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
DS1/E1
Jitter
Atten
Block
VT/TU
De-Mapper
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT 2 - Reserved
BIT[1:0] - M23 Loop-back Codes[1:0]
These READ/WRITE bit-fields are used to specify the coding (or the values that the Transmit DS3 Framer block will set
the C-bits to) in order to request the remote terminal equipment to operate in the remote DS3 Loop-back Mode.
Codes to Request Remote DS3 Loop-Back Mode
M23 LOOP-BACK
CODES[1:0]
C-BIT SETTINGS TO REQUEST
DS2 LOOP-BACK CODES
COMMENTS
00/11
Cj1 = Cj2 = Cj3*
The Transmit DS3 Framer block will invert the state of
the Cj3 bit (from that of the corresponding Cj1 and Cj2
bits) in order to request that the remote terminal execute
a DS2 remote Loop-back within the jth DS2 Channel.
01
Cj1 = Cj2* = Cj3
The Transmit DS3 Framer block will insert the state of
the of the Cj2 bit (from that of the corresponding Cj1 and
Cj3 bits) in order to request that the remote terminal execute a remote Loop-back within the jth DS2 Channel.
10
Cj1* = Cj2 = Cj3
The Transmit DS3 Framer block will invert the state of
the Cj1 bit (from that of the corresponding Cj2 and Cj3
bits) in order to request that the remote terminal execute
a remote Loop-back within the jth DS2 Channel.
NOTE: Anytime the Transmit DS3 Framer block has been configured to transmit a DS2 Loop-back request code to the
remote terminal equipment, then it will set the C-bits to the appropriate value (based upon the user-selection)
as specified in the above table. Further, the Transmit DS3 Framer block will transmit these DS2 Loop-back
request codes (to the remote terminal equipment) for the appropriate DS2 channel, whenever the user
183
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
commands it to do so by setting any one of the bits within the DS3 Framer Block - M23 - DS2 Loop-back
Request Register (Address = 0x0E09) to 1.
TABLE 243: DS3 FRAMER BLOCK - M23 TRANSMIT DS2 AIS COMMAND REGISTER (ADDRESS = 0X0E08)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Transmit
DS2
AIS - DS2
Channel 6
Transmit
DS2
AIS - DS2
Channel 5
Transmit
DS2
AIS - DS2
Channel 4
Transmit
DS2
AIS - DS2
Channel 3
Transmit
DS2
AIS - DS2
Channel 2
Transmit
DS2
AIS - DS2
Channel 1
Transmit
DS2
AIS - DS2
Channel 0
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved
BIT6 - Transmit DS2 AIS - DS2 Channel 6:
This READ/WRITE bit-field is used to configure the M12 MUX block (associated with DS2 Channel 6) to transmit the
DS2 AIS indicator, towards the Transmit DS3 Framer block (and within the outbound DS3 data-stream).
` 0 - Configures the M12 MUX block (associated with DS2 Channel 6) to transmit normal data.
` 1 - Configures the M12 MUX block (associated with DS2 Channel 6) to transmit the DS2 AIS indicator.
Figure 12 presents an illustration of the XRT86SH328, whenever the M12 MUX has been configured to
transmit the DS2 AIS indicator towards both the M23 MUX and the Transmit DS3 Framer blocks.
FIGURE 12. AN ILLUSTRATION OF THE XRT86SH328, WHENEVER THE M12 MUX HAS BEEN CONFIGURED TO
TRANSMIT THE DS2 AIS INDICATOR TOWARDS BOTH THE M23 MUX AND THE TRANSMIT DS3 FRAMER BLOCK
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
M23
M23
MUX
MUX
Block
Block
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
MUX
Block
DS2 AIS Pattern
M12
De-MUX
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
From DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT 5 - Transmit DS2 AIS - DS2 Channel 5:
See BIT6 description.
184
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT 4 - Transmit DS2 AIS - DS2 Channel 4:
See BIT6 description.
TBIT 3 - Transmit DS2 AIS - DS2 Channel 3:
See BIT6 description.
BIT 2 - Transmit DS2 AIS - DS2 Channel 2:
See BIT6 description.
BIT 1 - Transmit DS2 AIS - DS2 Channel 1:
See BIT6 description.
BIT 0 - Transmit DS2 AIS - DS2 Channel 0
See BIT6 description.
TABLE 244: DS3 FRAMER BLOCK - M23 - DS2 LOOP-BACK REQUEST REGISTER (ADDRESS = 0X0E09)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Transmit
DS2 Loopback
Request DS2
Channel 6
Transmit
DS2 Loopback
Request DS2
Channel 5
Transmit
DS2 Loopback
Request DS2
Channel 4
Transmit
DS2 Loopback
Request DS2
Channel 3
Transmit
DS2 Loopback
Request DS2
Channel 2
Transmit
DS2 Loopback
Request DS2
Channel 1
Transmit
DS2 Loopback
Request DS2
Channel 0
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT6 - Transmit DS2 Loop-back Request - DS2 Channel 6:
This READ/WRITE bit-field is used to command the Transmit DS3 Framer block to transmit the Loop-back Request
indicator, for DS2 Channel 6.
` 0 - The Transmit DS3 Framer block will NOT transmit the Loop-back Request for DS2 Channel #6 (Normal Operation)
` 1 - The Transmit DS3 Framer block will transmit the Loop-back Request for DS2 Channel # 6.
NOTE: Whenever the user executes this command, then the Transmit DS3 Framer block will invert the appropriate Cbit of the three (e.g., C71, C72 or C73) based upon the user's setting of Bits 1 and 0 (M23 Loop-back
Codes[1:0]) within the DS3 Framer Block - M23 Configuration Register (Address = 0x0E07).
BIT 5 - Transmit DS2 Loop-back Request - DS2 Channel 5:
See BIT6 description.
BIT 4 - Transmit DS2 Loop-back Request - DS2 Channel 4:
See BIT6 description.
BIT 3 - Transmit DS2 Loop-back Request - DS2 Channel 3:
See BIT6 description.
BIT 2 - Transmit DS2 Loop-back Request - DS2 Channel 2:
See BIT6 description.
BIT 1 - Transmit DS2 Loop-back Request - DS2 Channel 1:
See BIT6 description.
BIT 0 - Transmit DS2 Loop-back Request - DS2 Channel 0:
See BIT6 description.
185
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 245: DS3 FRAMER BLOCK - M23 LOOP-BACK ACTIVATION REGISTER (ADDRESS = 0X0E0A)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Remote DS2
Loop-back DS2 Channel 6
Remote DS2
Loop-back DS2 Channel 5
Remote DS2
Loop-back DS2 Channel 4
Remote DS2
Loop-back DS2 Channel 3
Remote DS2
Loop-back DS2 Channel 2
Remote DS2
Loop-back DS2 Channel 1
Remote DS2
Loop-back DS2 Channel 0
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved
BIT6 - Remote DS2 Loop-back - DS2 Channel 6
This READ/WRITE bit-field is used to configure the XRT86SH328 to perform a Remote Loop-back of DS2 Channel 6.
If the user configures the XRT86SH328 to perform this loop-back, then the Receive Direction DS2 signal (associated
with Channel 6) will internally be looped back into the Transmit Direction.
` 0 - Configures DS2 Channel 6 to operate in the Normal (No Loop-back) Mode
` 1 - Configures DS2 Channel 6 to operate in the Remote Loop-back Mode.
Figure 13 presents an illustration of the Functional Block diagram of the XRT86SH328, whenever a given DS2
Channel has been configured to operate in the Remote DS2 Loop-back Mode.
FIGURE 13. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN
DS2 CHANNEL HAS BEEN CONFIGURED TO OPERATE IN THE REMOTE DS2 LOOP-BACK MODE
DS2 Remote Loop-back in
DS2 Channel 0
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
From DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT 5 - Remote DS2 Loop-back - DS2 Channel 5
See BIT6 description.
186
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT 4 - Remote DS2 Loop-back - DS2 Channel 4
See BIT6 description.
BIT 3 - Remote DS2 Loop-back - DS2 Channel 3
See BIT6 description.
BIT 2 - Remote DS2 Loop-back - DS2 Channel 2
See BIT6 description.
BIT 1 - Remote DS2 Loop-back - DS2 Channel 1
See BIT6 description.
BIT 0 - Remote DS2 Loop-back - DS2 Channel 0
See BIT6 description.
TABLE 246: DS3 FRAMER BLOCK - M23 MUX FORCE RECEIVE DS2 AIS COMMAND REGISTERS (ADDRESS =
0X0E0B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Generate
DS2 AIS
Receive
Path - DS2
Channel 7
Generate
DS2 AIS
Receive
Path - DS2
Channel 6
Generate
DS2 AIS
Receive
Path - DS2
Channel 5
Generate
DS2 AIS
Receive
Path - DS2
Channel 4
Generate
DS2 AIS
Receive
Path - DS2
Channel 3
Generate
DS2 AIS
Receive
Path - DS2
Channel 2
Generate
DS2 AIS
Receive
Path -DS2
Channel 1
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT6 - Generate DS2 AIS Receive Path - DS2 Channel 7
This READ/WRITE bit-field is used to configure the M23 De-MUX block to overwrite the contents of the de-muxed DS2
data-stream (associated with DS2 Channel 7) with the DS2 AIS indicator in the Egress Direction, towards its
corresponding (down-stream) M12 De-MUX block.
` 0 - The M23 De-MUX block will transmit normal DS2 data to the down-stream circuitry.
` 1 - The M23 De-MUX block will transmit the DS2 AIS indicator within DS2 Channel 7, within the Egress Direction.
Figure 14 presents an illustration of the Functional Block diagram of the XRT86SH328, whenever a given DS2
Channel has been configured to transmit the DS2 AIS indicator in the Egress Direction.
187
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
FIGURE 14. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE M23
DE-MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR IN THE EGRESS DIRECTION OF DS2 CHANNEL 0
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
M23
M23
MUX
MUX
Block
Block
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
MUX
Block
DS2 AIS Pattern
M12
De-MUX
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
From DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT 5 - Generate DS2 AIS Receive Path - DS2 Channel 6
See BIT 6 description.
BIT 4 - Generate DS2 AIS Receive Path - DS2 Channel 5
See BIT 6 description.
BIT 3 - Generate DS2 AIS Receive Path - DS2 Channel 4
See BIT 6 description.
BIT 2 - Generate DS2 AIS Receive Path - DS2 Channel 3
See BIT 6 description.
BIT 1 - Generate DS2 AIS Receive Path - DS2 Channel 2
See BIT 6 description.
BIT 0 - Generate DS2 AIS Receive Path - DS2 Channel 1
See BIT 6 description.
188
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 247: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER (ADDRESS = 0X0E0C)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
PRBS Lock
Detect
PRBS
Receiver
Enable
PRBS
Generator
Enable
BIT 1
BIT 0
Reserved
R/O
R/O
R/O
R/O
R/W
R/W
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:5] - Reserved
BIT 4 - PRBS Lock Detect
This READ-ONLY bit-field indicates whether or not the PRBS Receiver (within the Receive DS3 Framer block) has
acquired PRBS Lock with the payload data of the incoming DS3 data-stream, as described below.
` 0 - Indicates that the PRBS Receiver does not have PRBS Lock with the incoming data-stream.
` 1 - Indicates that the PRBS Receiver does have PRBS Lock with the incoming data-stream.
NOTE: This bit-field is only valid if the PRBS Receiver has been enabled.
BIT 3 - PRBS Receiver Enable
This READ/WRITE bit-field is used to either enable or disable the PRBS Receiver within the Receive DS3 Framer block.
Once the user enables the PRBS Receiver, then it will proceed to attempt to acquire and maintain pattern sync (or PRBS
Lock) within the payloadbits, within the incoming DS3 data-stream.
` 0 - Disables the PRBS Receiver
` 1 - Enables the PRBS Receiver.
BIT 2 - PRBS Generator Enable
This READ/WRITE bit-field is used to either enable or disable the PRBS Generator within the Transmit DS3 Framer
block. Once the user enables the PRBS Generator block, then it will proceed to insert a PRBS Pattern into the payload
bits, within the outbound DS3 data-stream.
` 0 - Disables the PRBS Generator
` 1 - Enables the PRBS Generator.
BIT 1 - Receive DS3 Framer By-Pass
BIT 0 - Transmit DS3 Framer By-Pass
TABLE 248: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER # 2 (ADDRESS = 0X0E0E)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Unused
PRBS Type
R/O
R/W
R/W
R/W
R/O
R/O
R/O
R/W
0
0
0
0
0
0
0
0
BER Control[1:0]
BIT 2
BIT 1
Unused
BIT 0
Unframed
PRBS
BIT7 - Unused
BIT6 - PRBS Type
This READ/WRITE bit-field is used to select between two possible PRBS Patterns, that the PRBS Generator and
Receiver will be handling.
` 0 - The PRBS Generator and Receiver will be handling a 2^15-1 PRBS Pattern.
` 1 - The PRBS Generator and Receiver will be handling a 2^23-1 PRBS Pattern.
NOTE: This READ/WRITE bit-field is only active if the PRBS Receiver and Generator have been enabled.
BIT[5:4] - BER Control[1:0]
189
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
These two READ/WRITE bit-fields are used to select the rate at which the PRBS Generator (within the
Transmit DS3 Framer block) will generate and transmit Bit-Errors, within the outbound DS3/PRBS DataStream.
The Relationship between the BER Control[1:0] bit-fields and the Resulting Bit Error-Rate that the
PRBS Generator will. Insert within the outbound DS3/PRBS data-stream
RESULTING BIT ERROR RATE INSERTED WITHIN THE OUTBOUND DS3/PRBS
DATA-STREAM
BER CONTROL[1:0]
00, 11
No Bit Errors Selected (Normal Operation)
01
1 Bit per 1000 Bits are Erred
10
1 Bit per 1,000,000 Bits are Erred
NOTE: These bit-fields are only active if the PRBS Generator has been enabled.
BIT[3:1] - Unused
BIT 0 - Unframed PRBS
This READ/WRITE bit-field is used to configure the PRBS Generator and the Transmit DS3 Framer block to
transmit either a Frame or an Unframed PRBS Pattern, within the outbound DS3 data-stream.
` 0 - Configures the PRBS Generator/Transmit DS3 Framer to transmit a Framed PRBS Pattern, whenever the PRBS
Generator has been enabled.
` 1 - Configures the PRBS Generator/Transmit DS3 Framer to transmit an Unframed PRBS Pattern, whenever the
PRBS Generator has been enabled.
NOTE: This bit-field is only active if the PRBS Generator has been enabled.
TABLE 249: DS3 FRAMER BLOCK - RECEIVE DS3 CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E10)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS3 AIS
Defect
Declared
DS3 LOS
Defect
Declared
DS3 Idle
Pattern
Declared
DS3 OOF
Defect
Declared
Reserved
Framing with
Valid P-Bits
F Sync Algo
M Sync Algo
R/O
R/O
R/O
R/O
R/O
R/W
R/W
R/W
0
0
0
1
0
1
0
0
BIT7 - DS3 AIS Defect Declared:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the AIS defect
condition, within the incoming DS3 data-stream.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the AIS defect condition within the
incoming DS3 data-stream.
` 1 - Indicates that the Receive DS3 Framer block is currently declaring the AIS defect condition within the incoming
DS3 data-stream.
BIT6 - DS3 LOS Defect Declared:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the LOS defect
condition, within the incoming DS3 data-stream.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the LOS defect condition within the
incoming DS3 data-stream.
` 1 - Indicates that the Receive DS3 Framer block is currently declaring the LOS defect condition within the incoming
DS3 data-stream.
BIT 5 - DS3 Idle Pattern Declared:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the DS3 Idle
190
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Pattern, within the incoming DS3 data-stream.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the Idle Pattern condition within the
incoming DS3 data-stream.
` 1 - Indicates that the Receive DS3 Framer block is currently declaring the Idle Pattern condition within the incoming
DS3 data-stream.
BIT 4 - DS3 OOF Defect Declared:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the OOF (Outof-Frame) defect condition.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the OOF defect condition.
` 1 - Indicates that the Receive DS3 Framer block is currently declaring the OOF defect condition.
BIT 3 - Reserved:
BIT 2 - Framing with Valid P-Bits:
This READ/WRITE bit-field is used to configure the Receive DS3 Framer block to use either of the following two different
sets of DS3 Frame Acquisition/Maintenance criteria.
•
Normal Framing Acquisition/Maintenance Criteria (without P-bit Checking)
In this mode, the Receive DS3 Framer block will declare the In-Frame state, once it has successfully completed both
the F-Bit Search and the M-Bit Search states.
•
Framing Acquisition/Maintenance with P-bit Checking:
In this mode, the Receive DS3 Framer block will (in addition to passing through the F-Bit Search and M-Bit Search
states) also verify valid P-bits prior to declaring the In-Frame state.
` 0 - Configures the Receive DS3 Framer block to use the Normal Framing Acquisition/Maintenance Criteria (without
P-bit Checking)
` 1 - Configures the Receive DS3 Framer block to use the Framing Acquisition/Maintenance with P-Bit Checking
criteria.
BIT 1 - F-Bit Search State Criteria Select:
This READ/WRITE bit-field is used to configure the Receive DS3 Framer block to use either one of the following DS3
Out-of-Frame (OOF) Defect Declaration criteria.
` 0 - Configures the Receive DS3 Framer block to declare the OOF defect condition, whenever it determines that 6 out
of the most recent 15 F-bits (within the incoming DS3 data-stream) are erred.
` 1 - Configures the Receive DS3 Framer block to declare the OOF defect condition whenever it determines that 3 out
of the most recent 15 F-bits (within the incoming DS3 data-stream) are erred.
BIT 0 - M-Bit Search State Criteria:
This READ/WRITE bit-field is used to configure the Receive DS3 Framer block to use either one of the following DS3
Out-of-Frame (OOF) Defect Declaration criteria.
` 0 - Configures the Receive DS3 Framer block to NOT declare the OOF defect condition whenever it detects M-bit
errors.
` 1 - Configures the Receive DS3 Framer block to declare the OOF defect condition whenever it detects M-bit errors
within 3 out of 4 of the most recently received DS3 frames.
TABLE 250: DS3 FRAMER BLOCK - RECEIVE DS3 STATUS REGISTER (ADDRESS = 0X0E11)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
DS3
FERF/RDI
Defect
Declared
Received
AIC State
BIT 2
BIT 1
BIT 0
Received FEBE[2:0] Values
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT7 - 5 - Reserved:
191
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT 4 - DS3 FERF/RDI Defect Declared:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the FERF/RDI
defect condition.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the FERF/RDI defect condition.
` 1 - Indicates that the Receive DS3 Framer block is currently declaring the FERF/RDI defect condition.
BIT 3 - Received AIC State:
This READ-ONLY bit-field reflects the current state of the AIC bit-field within the incoming DS3 data-stream.
` 0 - Indicates that the Receive DS3 Framer block has received at least 2 consecutive M-frames that have the AIC bitfield set to 0.
` 1 - Indicates that the Receive DS3 Framer block has received at least 63 consecutive M-frames that have the AIC bitfield set to 1.
BIT[2:0] - Received FEBE[2:0] Value:
These READ-ONLY bit-fields reflects the FEBE value within the most recently received DS3 frame.
` Received FEBE[2:0] = [1, 1, 1] reflects a normal condition. All other values for Received FEBE[2:0] indicates an erred
condition at the remote terminal equipment.
NOTE: This bit-field is only active if the Transmit/Receive DS3 Framer blocks have been configured to operate in the
C-bit Parity Framing format.
TABLE 251: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E12)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Detection of
CP-Bit Error
Interrupt
Enable
Change of
DS3 LOS
Defect
Condition
Interrupt
Enable
Change of
DS3 AIS
Defect
Condition
Interrupt
Enable
Change of
DS3 Idle
Condition
Interrupt
Enable
Change of
DS3
FERF/RDID
efect
Condition
Interrupt
Enable
Change of
AIC State
Interrupt
Enable
Change of
DS3 OOF
Defect
Condition
Interrupt
Enable
Detection of
P-Bit Error
Interrupt
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Detection of CP-Bit Error Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Detection of CP-bit Error interrupt, within the
XRT86SH328. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime it
detects at least one CP-bit error within the incoming DS3 data-stream.
` 0 - Disables the Detection of CP-Bit Error Interrupt.
` 1 - Enables the Detection of CP-Bit Error Interrupt.
NOTE: This bit-field is only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in
the C-bit Parity framing format.
BIT6 - Change of DS3 LOS Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change in DS3 LOS (Loss of Signal) defect condition,
within the XRT86SH328. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in
response to either of the following conditions.
•
The instant that the Receive DS3 Framer block declares the LOS defect condition.
•
The instant that the Receive DS3 Framer block clears the LOS defect condition.
` 0 - Disables the Change in DS3 LOS Defect Condition Interrupt.
` 1 - Enables the Change in DS3 LOS Defect Condition Interrupt.
BIT 5 - Change of DS3 AIS Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change in DS3 AIS (Alarm Indication Signal) defect
condition interrupt within the XRT86SH328. If this interrupt is enabled, then the Receive DS3 Framer block will generate
192
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
an interrupt in response to either of the following events.
•
The instant that the Receive DS3 Framer block declares the AIS defect condition.
•
The instant that the Receive DS3 Framer block clears the AIS defect condition.
` 0 - Disables the Change in AIS Defect Condition interrupt.
` 1 - Enables the Change in DS3 AIS Defect Condition Interrupt.
BIT 4 - Change of DS3 Idle Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change in DS3 Idle Condition interrupt, within the
Receive DS3 Framer block. If the user enables this interrupt then the Receive DS3 Framer block will generate an
interrupt in response to either of the following conditions.
•
The instant that the Receive DS3 Framer block detects and declares the DS3 Idle condition.
•
The instant that the Receive DS3 Framer block clears the DS3 Idle condition.
` 0 - Disables the Change in DS3 Idle Condition Interrupt.
` 1 - Enables the Change in DS3 Idle Condition Interrupt.
BIT 3 - Change of DS3 FERF/RDI Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change in DS3 FERF/RDI Defect Condition Interrupt.
If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in response to either of the
following condition.
•
The instant that the Receive DS3 Framer block declares the FERF/RDI defect condition.
•
The instant that the Receive DS3 Framer block clears the FERF/RDI defect condition.
` 0 - Disables the Change in DS3 FERF/RDI Defect Condition Interrupt.
` 1 - Enables the Change in DS3 FERF/RDI Defect Condition Interrupt.
BIT 2 - Change of AIC State Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change in AIC State interrupt. If this interrupt is
enabled, then the Receive DS3 Framer block will generate an interrupt in response to it detecting a change in the AIC
bit-field, within the incoming DS3 data-stream.
` 0 - Disables the Change of AIC State Interrupt.
` 1 - Enables the Change of AIC State Interrupt.
BIT 1 - Change of DS3 OOF Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of DS3 OOF Defect Condition
Interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in response
to either of the following conditions.
•
The instant that the Receive DS3 Framer block declares the DS3 OOF Defect Condition.
•
The instant that the Receive DS3 Framer block cleares the DS3 OOF Defect Condition.
` 0 - Disables the Change in DS3 OOF Defect Condition Interrupt.
` 1 - Enables the Change in DS3 OOF Defect Condition Interrupt.
BIT 0 - Detection of P-Bit Error Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Detection of P-Bit Error Interrupt. If this
interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime it detects P-bit
errors within the incoming DS3 data-stream.
` 0 - Disables the Detection of P-Bit Error Interrupt
` 1 - Enables the Detection of P-Bit Error Interrupt
193
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 252: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT STATUS REGISTER (ADDRESS = 0X0E13)
BIT7
Detection of
CP-Bit Error
Interrupt
Status
BIT6
BIT 5
Change of
Change of
DS3 LOS
DS3 AIS
Defect
Defect
Condition
Condition
Interrupt Sta- Interrupt Status
tus
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
DS3 Idle
Condition
Interrupt
Status
Change of
DS3
FERF/RDID
efect
Condition
Interrupt
Status
Change of
AIC State
Interrupt
Status
Change of
DS3 OOF
Defect
Condition
Interrupt
Status
Detection of
P-Bit Error
Interrupt
Status
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT7 - Detection of CP-Bit Error Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Detection of CP-Bit Error Interrupt has occurred since the
last read of this register.
` 0 - Indicates that the Detection of CP-Bit Error Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of CP-Bit Error Interrupt has occurred since the last read of this register.
NOTE: This bit-field is only active if the Transmit and Receive DS3 Framer block are configured to operate in the C-Bit
Parity Framing Format.
BIT6 - Change of DS3 LOS Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change in DS3 LOS Defect Condition Interrupt has
occurred since the last read of this register.
` 0 - Indicates that the Change in DS3 LOS Defect Condition Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the Change in DS3 LOS Defect Condition Interrupt has occurred since the last read of this register.
BIT 5 - Change of DS3 AIS Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change of DS3 AIS Defect Condition Interrupt has
occurred since the last read of this register.
` 0 - Indicates that the Change of DS3 AIS Defect Condition Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the Change of DS3 AIS Defect Condition Interrupt has occurred since the last read of this register.
BIT 4 - Change of DS3 Idle Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change in DS3 Idle Condition interrupt has
occurred since the last read of this register.
` 0 - Indicates that the Change of DS3 Idle Condition Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Change of DS3 Idle Condition Interrupt has occurred since the last read of this register.
BIT 3 - Change of DS3 FERF/RDI Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change of DS3 FERF/RDI Defect Condition Interrupt has
occurred since the last read of this register.
` 0 - Indicates that the Change of DS3 FERF/RDI Defect Condition interrupt has NOT occurred since the last read of
this register.
` 1 - Indicates that the Change in DS3 FERF/RDI Defect Condition interrupt has occurred since the last read of this
register.
BIT 2 - Change of AIC State Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change in AIC State Interrupt has occurred since the last
read of this register.
` 0 - Indicates that the Change in AIC State interrupt has NOT occurred since the last read of this register.
194
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 1 - Indicates that the Change in AIC State Interrupt has occurred since the last read of this register.
BIT 1 - Change of DS3 OOF Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change in DS3 OOF Defect Condition interrupt has
occurred since the last read of this register.
` 0 - Indicates that the Change of DS3 OOF Defect Condition Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the Change of DS3 OOF Defect Condition Interrupt has occurred since the last read of this register.
BIT 0 - Detection of P-Bit Error Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Detection of P-Bit Error Interrupt has occurred
since the last read of this register.
` 0 - Indicates that the Detection of P-Bit Error Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Detection of P-Bit Error Interrupt has occurred since the last read of this register.
TABLE 253: DS3 FRAMER BLOCK - RECEIVE DS3 SYNC DETECT REGISTER (ADDRESS = 0X0E14)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
F - Sync
Algorithm
One and
Only
R/O
R/O
R/O
R/O
R/O
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT[7:2] - Reserved:
BIT 1 - F-Sync Algorithm
This READ/WRITE bit-field is used to select the F-bit acquisition criteria when the Receive DS3 Framer block is
operating in the F-Bit Search state.
` 0 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, when it has properly located 10
consecutive F-bits.
` 1 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, when it has properly located 16
consecutive F-bits.
BIT 0 - One and Only:
This READ/WRITE bit-field is used to select the F-bit acquisition criteria that the Receive DS3 Framer block will use,
whenever it is operating in the F-Bit Search state, as described below.
` 0 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, whenever it has properly located
10 (or 16) consecutive F-bits (as configured in BIT 1 of this register).
` 1 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, whenever (1) it has properly
located 10 (or 16) consecutive F-bits and (2) when it has located and identified only one viable F-Bit Alignment
candidate.
NOTE: If this bit is set to 1, then the Receive DS3 Framer block will NOT transition into the M-Bit Search state as long
as at least two viable candidate sets of bits appears to function as the F-bits.
TABLE 254: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC REGISTER (ADDRESS = 0X0E16)
BIT7
BIT6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
RxFEAC_Code[5:0]
BIT 0
Unused
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
1
1
1
1
1
1
0
BIT7 - Unused:
BIT[6:1] - Receive FEAC Code[5:0]:
195
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
These READ-ONLY bit-fields contain the value of the most recently validated FEAC Code word.
NOTE: These register bits are only active if the Transmit and Receive DS3 Framer blocks have been configured to
operate in the C-bit Parity Framing format.
BIT 0 - Unused:
TABLE 255: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC INTERRUPT ENABLE/STATUS REGISTER (ADDRESS =
0X0E17)
BIT7
BIT6
BIT 5
Set to [0, 0, 0]
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
FEAC Valid
Receive
FEAC
Removal
Interrupt
Enable
Receive
FEAC
Removal
Interrupt
Status
Receive
FEAC Valid
Interrupt
Enable
Receive
FEAC Valid
Interrupt
Status
R/W
R/W
R/W
R/O
R/W
RUR
R/W
RUR
0
0
0
0
0
0
0
0
Bits 7 - 5 - Set to [0, 0, 0]:
` Please set these three bit-fields to 0 (the default value) for normal operation.
BIT 4 - FEAC Message Valid:
This READ-ONLY bit-field indicates that the FEAC Code word (which resides within the Receive DS3 FEAC Register)
has been validated by the Receive FEAC Controller block. The Receive FEAC Controller block will validate a FEAC
Codeword if it has received this same codeword in 8 out of the last 10 FEAC Messages.
Polled systems can monitor this bit-field when checking for a newly validated FEAC Codeword.
` 0 - Indicates that the FEAC Message (residing in the Receive DS3 FEAC register) is no longer validated.
` 1 - Indicates that the FEAC Message (residing in the Receive DS3 FEAC register) has been validated.
BIT 3 - Receive FEAC Removal Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Receive FEAC Message Removal interrupt. If this
interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime the most recently validated
FEAC Message has been removed. The Receive FEAC Controller will remove a validated FEAC codeword, if it has
received a different codeword in 3 out of the last 10 FEAC Messages.
` 0 - Disables the Receive FEAC Message Removal Interrupt.
` 1 - Enables the Receive FEAC Message Removal Interrupt.
BIT 2 - Receive FEAC Removal Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Receive FEAC Message Removal Interrupt has occurred
since the last read of this register.
` 0 - Indicates that the Receive FEAC Message Removal Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Receive FEAC Message Removal Interrupt has occurred since the last read of this register.
BIT 1 - Receive FEAC Valid Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Receive FEAC Message Validation Interrupt.
If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime the Receive
FEAC Controller block has validated a new FEAC Code word.
` 0 - Disables the Receive FEAC Message Validation Interrupt.
` 1 - Enables the Receive FEAC Message Validation Interrupt.
BIT 0 - Receive FEAC Valid Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Receive FEAC Message Validation Interrupt has
occurred since the last read of this register.
` 0 - Indicates that the Receive FEAC Message Validation Interrupt has NOT occurred since the last read of this
196
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
register.
` 1 - Indicates that the Receive FEAC Message Validation Interrupt has occurred since the last read of this register.
TABLE 256: DS3 FRAMER BLOCK - RECEIVE LAPD CONTROL REGISTER (ADDRESS = 0X0E18)
BIT7
BIT6
BIT 5
Receive Any
Kind of
LAPD
Message
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
Receive
LAPD
Controller
Block Enable
Receive
LAPD
Message
Interrupt
Enable
Receive
LAPD
Message
Interrupt
Status
R/W
R/O
R/O
R/O
R/O
R/W
R/W
RUR
0
0
0
0
0
0
0
0
BIT7 - Receive Any Kind of LAPD Message:
This READ/WRITE bit-field is used to configure the Receive LAPD Controller block to receive any kind of LAPD
Message (or HDLC Message) with a size of 82 bytes or less. If the user implements this option, then the Receive LAPD
Controller block will be capable of receiving any kind of HDLC Message (with any value the header bytes). The only
restriction is that the size of the HDLC Message must not exceed 82 bytes.
` 0 - Does not invoke the Any Kind of HDLC Message feature.
In this case, the Receive LAPD Controller block will only receive HDLC Messages that contains the Bellcore GR-499CORE values for SAPI and TEI.
` 1 - Invokes this Any Kind of HDLC Message feature.
In this case, the Receive LAPD Controller block will be able to receive HDLC Messages that contains any header byte
values.
NOTE: The user can determine the size (or byte count) of the most recently received LAPD/PMDL Message by reading
the contents of the Receive LAPD Byte Count Register (Address = 0x0E84).
BIT[6:3] - Unused:
BIT 2 - Receive LAPD Controller Block Enable:
This READ/WRITE bit-field is used to either enable or disable the Receive LAPD Controller block within the Receive
DS3 Framer block. If the user enables the Receive LAPD Controller block, then it will immediately begin extracting out
and monitoring the data (being carried via the DL bits) within the incoming DS3 data-stream.
` 0 - Disables the Receive LAPD Controller block.
` 1 - Enables the Receive LAPD Controller block.
BIT 1 - Receive LAPD Message Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Receive LAPD Message Interrupt. If this interrupt is
enabled, then the Receive DS3 Framer block will generate an interrupt anytime the Receive LAPD Controller block
receives a new PMDL Message.
` 0 - Disables the Receive LAPD Message Interrupt.
` 1 - Enables the Receive LAPD Message Interrupt.
BIT 0 - Receive LAPD Message Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Receive LAPD Message Interrupt has occurred since the
last read of this register.
` 0 - Indicates that the Receive LAPD Message Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Receive LAPD Message' Interrupt has occurred since the last read of this register.
197
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 257: DS3 FRAMER BLOCK - RECEIVE DS3 LAPD STATUS REGISTER (ADDRESS = 0X0E19)
BIT7
BIT6
BIT 5
Unused
Receive
ABORT
R/O
R/O
R/O
0
0
0
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive C/R
Type
Receive
LAPD FCS
Error
Detected
End of
Message
Flag
Sequence
Present
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
RxLAPD_Msg_Type[1:0]
BIT7 - Unused:
BIT6 - Receive ABORT:
This READ-ONLY bit-field indicates that the Receive LAPD Controller block has received an ABORT sequence (e.g., a
string of seven consecutive 0s) within the incoming data-stream.
` 0 - Indicates that the Receive LAPD Controller block has NOT received an ABORT sequence.
` 1 - Indicates that the Receive LAPD Controller block has received an ABORT sequence.
NOTE: Once the Receive LAPD Controller block receives an ABORT Sequence, it will set this bit-field high until it
receives another LAPD Message.
BIT[5:4] - Receive LAPD Message Type[1:0]:
These two READ-ONLY bit-fields indicate the type of LAPD Message that is residing within the Receive LAPD Message
Buffer. The relationship between the contents of these two bit-fields and the corresponding message type is presented
below.
Message Type
RECEIVE LAPD MESSAGE TYPE[1:0]
MESSAGE TYPE
0
0
CL Path Identification
0
1
Idle Signal Identification
1
0
Test Signal Identification
1
1
ITU-T Path Identification
BIT 3 - Receive C/R Type:
This READ-ONLY bit-field indicates the value of the C/R bit-field (within one of the header bytes) of the most recently
received LAPD Message.
BIT 2 - Receive LAPD FCS Error Detected:
This READ-ONLY bit-field indicates whether or not the most recently received LAPD Message frame contained an FCS
error or not.
` 0 - Indicates that the most recently received LAPD Message frame does not contain an FCS error.
` 1 - Indicates that the most recently received LAPD Message frame does contain an FCS error.
BIT 1 - End of Message:
This READ-ONLY bit-field indicates whether or not the Receive LAPD Controller block has received a complete LAPD
Message.
` 0 - Indicates that the Receive LAPD Controller block is currently receiving a LAPD Message, but has not received the
complete message.
` 1 - Indicates that the Receive LAPD Controller block has received a complete LAPD Message.
NOTE: Once the Receive LAPD Controller block sets this bit-field high, this bit-field will remain high until the Receive
LAPD Controller block begins to receive a new LAPD Message.
BIT 0 - Flag Sequence Present:
198
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This READ-ONLY bit-field indicates whether or not the Receive LAPD Controller block is currently receiving the Flag
Sequence (e.g., a continuous stream of 0x7E octets within the Data Link channel).
` 0 - Indicates that the Receive LAPD Controller block is NOT currently receiving the Flag Sequence octet within the
incoming Data Link channel.
` 1 - Indicates that the Receive LAPD Controller block is currently receiving a continuous stream of Flag Sequence
octets within the incoming Data Link channel.
TABLE 258: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E1A)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7, 5 - Reserved
BIT 4 - Set G.747 Mode
This READ/WRITE bit-field is used to configure the M12 MUX and De-MUX (associated with DS2 Channel # 1) to
operate in either the DS2 or the G.747 Mode. If the user configures the M12 MUX and De-MUX to operate in the DS2
Mode, then all of the following will be true.
•
The M12 MUX will multiplex four (4) DS1 signals into a DS2 signal, prior to routing it to the M23 MUX.
•
The M12 De-MUX will accept a DS2 data-stream (from the M23 De-MUX) and it will de-multiplex this datastream into four (4) DS1 signals (prior to being output to the Egress Direction Receive DS1/E1 Framer block).
Likewise, if the user configures the M12 MUX and De-MUX to operate in the G.747 Mode, then all of the following will
be true.
•
The M12 MUX will multiplex three (3) E1 signals into a G.747 data-stream, prior to routing it to the M23 MUX
•
The M12 De-MUX will accept a G.747 data-stream (from the M23 De-MUX) and it will de-multiplex this datastream into three (3) E1 signals (prior to being output to the Egress Direction Receive DS1/E1 Framer block).
` 0 - Configures the M12 MUX (associated with DS2 Channel # 1) to operate in the DS2 Mode.
` 1 - Configures the M12 MUX (associated with DS2 Channel # 1) to operate in the G.747 Mode.
BIT 3 - Set G.747 Reserved Bit
This READ/WRITE bit-field is used to configure M12 MUX to set the Reserved bit (within a G.747 data-stream) to either
a 0 or 1.
` 0 - Configures the M12 MUX to set the G.747 Reserved bit (within the outbound G.747 data-stream) to 0.
` 1 - Configures the M12 MUX to set the G.747 Reserved bit (within the outbound G.747 data-stream) to 1.
NOTE: This bit-field is only active if the M12 MUX/De-MUX has been configured to operate in the G.747 Mode.
BIT 2 - Set M12 FERF Bit Value
Bits 1, 0 - M12 Loop-back Code[1:0]:
These READ/WRITE bit-fields are used to specify the coding (or the values that the M12 MUX block will set the C-bits,
within its outbound DS2 data-stream to) in order to request that the remote terminal equipment operate in the remote
DS1 Loop-back Mode.
199
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Loop-Back Codes
M12 LOOP-BACK
CODES[1:0]
C-BIT SETTINGS TO REQUEST
DS2 LOOP-BACK CODES
00/11
Cj1 = Cj2 = Cj3*
The M12 MUX block will invert the state of the Cj3 bit
(from that of the corresponding Cj1 and Cj2 bits) within
the outbound DS2 signal in order to request that the
remote terminal execute a remote Loop-back within the
jth DS1 signal.
01
Cj1 = Cj2* = Cj3
The M12 MUX block will insert the state of the of the Cj2
bit (from that of the corresponding Cj1 and Cj3 bits) within
the outbound DS2 signal in order to request that the
remote terminal execute a remote Loop-back within the
jth DS1 signal.
10
Cj1* = Cj2 = Cj3
The M12 MUX block will invert the state of the Cj1 bit
(from that of the corresponding Cj2 and Cj3 bits) in order
to request that the remote terminal execute a remote
Loop-back within the jth DS1 signal.
COMMENTS
NOTE: Anytime the M12 MUX block has been configured to transmit a DS2 Loop-back request code, then it will set the
C-bits to the appropriate value (based upon the user-selection) as specified in the above table.
TABLE 259: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E1B)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 2 for Channel 1.
TABLE 260: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E1C)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 3 for Channel 1.
TABLE 261: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E1D)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 4 for Channel 1.
200
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 262: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E1E)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 5 for Channel 1.
TABLE 263: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E1F)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 6 for Channel 1.
TABLE 264: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 7 (ADDRESS = 0X0E20)
BIT7
BIT6
BIT 5
Reserved
BIT 4
BIT 3
BIT 2
Set G.747
Mode
Set G.747
Reserved Bit
M12 FERF
Bit Setting
BIT 1
BIT 0
M12 Loop-back Code[1:0]
R/O
R/O
R/O
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 7 for Channel 1.
TABLE 265: DS3 FRAMER BLOCK - M12 DE-MUX FORCE DS1/E1 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS =
0X0E21)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 4
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 3
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 2
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 1
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 4
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 3
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 2
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Force Receive DS1/E1 AIS - DS1/E1 Channel 4
This READ/WRITE bit-field is used to force the M12 De-MUX Block (associated with DS2 Channel # 0) to overwrite the
Egress Direction or De-Multiplexed DS1/E1 Signal associated with DS1/E1 Channel 4, with a DS1/E1 AIS Pattern as it is
de-muxing this DS1/E1 signal from the incoming DS2 data-stream, as described below.
` 0 - Configures the M12 De-MUX block to NOT transmit the DS1/E1 AIS Pattern, via Egress Direction DS1/E1 Channel
4.
` 1 - Configures the M12 De-MUX block to transmit the DS1/E1 AIS Pattern, via Egress Direction DS1/E1 Channel 4.
201
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Figure 15 presents an illustration of the Functional Block diagram of the XRT86SH328, whenever a given M12
De-MUX block has been configured to transmit the DS1/E1 AIS indicator (within a given DS1/E1 signal) in the
Egress Direction.
NOTE: For normal operation, the user MUST set this bit-field to 0.
FIGURE 15. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN
M12 DE-MUX BLOCK HAS BEEN CONFIGURED TO TRANSMIT THE DS1/E1 AIS INDICATOR (WITHIN A GIVEN DS1/E1
SIGNAL) IN THE EGRESS DIRECTION
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
DS1/E1 AIS in Egress
Direction
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
From DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT6 - Force Receive DS1/E1 AIS - DS1/E1 Channel 3
See Description of BIT7.
BIT 5 - Force Receive DS1/E1 AIS - DS1/E1 Channel 2
See Description of BIT7.
BIT 4 - Force Receive DS1/E1 AIS - DS1/E1 Channel 1
See Description of BIT7.
BIT 3 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 4
This READ/WRITE bit-field is used to force the M12 MUX Block (associated with DS2 Channel # 0) to overwrite the
Ingress Direction DS1/E1 Signal (associated with DS1/E1 Channel 4, with a DS1/E1 AIS Pattern. If the user invoke this
feature, then the M12 MUX Block will transmit a DS1/E1 AIS pattern (within DS1/E1 Channel 4) towards the M23 MUX
Block.
` 0 - Configures the M12 MUX Block to NOT transmit the DS1/E1 AIS Pattern, via the Ingress Direction DS1/E1
Channel 3.
` 1 - Configures the M12 MUX Block to transmit the DS1/E1 AIS Pattern, via the Ingress Direction DS1/E1 Channel 3.
NOTE: For normal operation, the user MUST set this bit-field to 0.
BIT 2 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 3
See description of BIT 3.
BIT 1 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 2
202
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
See description of BIT 3.
BIT 0 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 1
See description of BIT 3.
TABLE 266: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E22)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 7
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 6
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 5
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 4
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 7
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 6
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 5
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 4
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 1 for DS2 Channel 0 and Receive
TABLE 267: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E23)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 11
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 10
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 9
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 8
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 11
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 10
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 9
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 8
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 2 for DS2 Channel 0 and Receive
TABLE 268: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E24)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 15
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 14
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 13
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 12
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 15
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 14
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 13
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 12
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 3 for DS2 Channel 0 and Receive
DS1/E1 AIS - DS1/E1 Channel [15:12] Receive DS1/E1 AIS - DS1/E1 Channel [3:0].
203
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 269: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E25)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 19
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 18
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 17
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 16
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 19
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 18
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 17
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 16
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 4 for DS2 Channel 0 and Receive
DS1/E1 AIS - DS1/E1 Channel [19:16] Receive DS1/E1 AIS - DS1/E1 Channel [3:0].
TABLE 270: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E26)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 23
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 22
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 21
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 20
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 23
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 22
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 21
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 20
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 5 for DS2 Channel 0 and Receive
DS1/E1 AIS - DS1/E1 Channel [23:20] Receive DS1/E1 AIS - DS1/E1 Channel [3:0].
TABLE 271: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E27)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 27
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 26
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 25
Force
Receive
DS1/E1 AIS
- DS1/E1
Channel 21
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 27
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 26
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 25
Force
Transmit
DS1/E1 AIS
- DS1/E1
Channel 24
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 5 for DS2 Channel 0 and Receive
DS1/E1 AIS - DS1/E1 Channel [27:21] Receive DS1/E1 AIS - DS1/E1 Channel [3:0].
204
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 272: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 1 (ADDRESS = 0X0E28)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 3
M12 Remote
Loop-Back
Mode - DS1
Channel 2
M12 Remote
Loop-Back
Mode - DS1
Channel 1
M12 Remote
Loop-Back
Mode - DS1
Channel 0
M12 LoopBack
Request DS1
Channel 3
M12 LoopBack
Request DS1
Channel 2
M12 LoopBack
Request DS1
Channel 1
M12 LoopBack
Request DS1
Channel 0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - M12 Remote Loop-Back Mode - DS1 Channel 3
This READ/WRITE bit-field is used to configure DS1 Channel 3 to operate in the M12 Remote Loop-back Mode. If the
user configures DS1 Channel 3 to operate in the M12 Remote Loop-back Mode, then the Egress Direction DS1 Channel
3 signal (as it is de-multiplexed from the DS2 signal by the M12 De-MUX block) will be internally looped back into the
Ingress Direction (back towards the M12 MUX block).
` 0 - Configures DS1 Channel 3 to NOT operate in the M12 Remote Loop-back Mode (Normal Operation)
` 1 - Configures DS1 Channel 3 to operate in the M12 Remote Loop-back Mode.
Figure 16 presents an illustration of the Functional Block Diagram of the XRT86SH328, whenever it has been
configured to operate in the M12 Remote Loop-back Mode.
FIGURE 16. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN
CONFIGURED TO OPERATE IN THE M12 REMOTE LOOP-BACK MODE
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
M23
M23
MUX
MUX
Block
Block
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
MUX
Block
M12 Remote
Loop-back
Path
DS2 Channel 0
M12
De-MUX
Block
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT6 - M12 Remote Loop-Back Mode - DS1 Channel 2
See description of BIT7.
BIT 5 - M12 Remote Loop-Back Mode - DS1 Channel 1
205
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
See description of BIT7.
BIT 4 - M12 Remote Loop-Back Mode - DS1 Channel 0
See description of BIT7.
BIT 3 - M12 Loop-back Request - DS1 Channel 3
This READ/WRITE bit-field is used to command the M12 MUX block to transmit the Loop-back Request indicator for
DS1 Channel 3.
` 0 - The M12 MUX block will NOT transmit the Loop-back Request for DS1 Channel 3 (Normal Operation).
` 1 - The M12 MUX block will transmit the Loop-back Request for DS1 Channel 3.
NOTE: Whenever the user executes this command, then the M12 MUX Block (associated with DS2 Channel # 0) will
invert the appropriate C-bits of the three (e.g., C41, C42 or C43) within the outbound DS2 data-stream based
upon the user's settings of Bits 1 and 0 (M12 Loop-back Codes[1:0]) within the DS3 Framer Block - M12
Configuration Register - DS2 Channel # 0 (Address = 0x0E1A).
BIT 2 - M12 Loop-back Request - DS1 Channel 2
See description of BIT 3.
BIT 1 - M12 Loop-back Request - DS1 Channel 1
See description of BIT 3.
BIT 0 - M12 Loop-back Request - DS1 Channel 0
See description of BIT 3.
TABLE 273: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 2 (ADDRESS = 0X0E29)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 7
M12 Remote
Loop-Back
Mode - DS1
Channel 6
M12 Remote
Loop-Back
Mode - DS1
Channel 5
M12 Remote
Loop-Back
Mode - DS1
Channel 4
M12 LoopBack
Request DS1
Channel 7
M12 LoopBack
Request DS1
Channel 6
M12 LoopBack
Request DS1
Channel 5
M12 LoopBack
Request DS1
Channel 4
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [7:4] for Channel [3:0}.
TABLE 274: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 3 (ADDRESS = 0X0E2A)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 11
M12 Remote
Loop-Back
Mode - DS1
Channel 10
M12 Remote
Loop-Back
Mode - DS1
Channel 9
M12 Remote
Loop-Back
Mode - DS1
Channel 8
M12 LoopBack
Request DS1
Channel 11
M12 LoopBack
Request DS1
Channel 10
M12 LoopBack
Request DS1
Channel 9
M12 LoopBack
Request DS1
Channel 8
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [11:8] for Channel [3:0}.
206
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 275: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 4 (ADDRESS = 0X0E2B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 15
M12 Remote
Loop-Back
Mode - DS1
Channel 14
M12 Remote
Loop-Back
Mode - DS1
Channel 13
M12 Remote
Loop-Back
Mode - DS1
Channel 12
M12 LoopBack
Request
DS1
Channel 15
M12 LoopBack
Request
DS1
Channel 14
M12 LoopBack
Request
DS1
Channel 13
M12 LoopBack
Request
DS1
Channel 12
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [15:12] for Channel [3:0}.
TABLE 276: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 5 (ADDRESS = 0X0E2C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 19
M12 Remote
Loop-Back
Mode - DS1
Channel 18
M12 Remote
Loop-Back
Mode - DS1
Channel 17
M12 Remote
Loop-Back
Mode - DS1
Channel 16
M12 LoopBack
Request DS1
Channel 19
M12 LoopBack
Request DS1
Channel 18
M12 LoopBack
Request DS1
Channel 17
M12 LoopBack
Request DS1
Channel 16
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [19:16] for Channel [3:0}.
TABLE 277: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 6 (ADDRESS = 0X0E2D)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 23
M12 Remote
Loop-Back
Mode - DS1
Channel 22
M12 Remote
Loop-Back
Mode - DS1
Channel 21
M12 Remote
Loop-Back
Mode - DS1
Channel 20
M12 LoopBack
Request DS1
Channel 23
M12 LoopBack
Request DS1
Channel 22
M12 LoopBack
Request DS1
Channel 21
M12 LoopBack
Request DS1
Channel 20
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [23:20] for Channel [3:0}.
TABLE 278: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 7 (ADDRESS = 0X0E2E)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
M12 Remote
Loop Back
Mode - DS1
Channel 27
M12 Remote
Loop-Back
Mode - DS1
Channel 26
M12 Remote
Loop-Back
Mode - DS1
Channel 25
M12 Remote
Loop-Back
Mode - DS1
Channel 24
M12 LoopBack
Request DS1
Channel 27
M12 LoopBack
Request DS1
Channel 26
M12 LoopBack
Request DS1
Channel 25
M12 LoopBack
Request DS1
Channel 24
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
207
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [27:24] for Channel [3:0}.
TABLE 279: DS3 FRAMER BLOCK - TRANSMIT DS3 CONFIGURATION REGISTER (ADDRESS = 0X0E30)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Force DS3
Tx
FERF/RDI
Force X-Bits
to 1
Transmit
DS3 Idle
Signal
Transmit AIS
Indicator
Transmit
LOS
Indicator
Transmit
FERF/RDI
upon LOS
Transmit
FERF/RDI
upon LOF
Transmit
FERF/RDI
upon AIS
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
1
1
1
BIT7 - Force Transmit DS3 FERF/RDI Indicator
This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the FERF/RDI indicator to the
remote terminal equipment by setting both of the X-bits (within each outbound DS3 frame) to 0.
` 0 - Does not force the Transmit DS3 Framer block to transmit the DS3 FERF/RDI indicator. In this case, the Transmit
DS3 Framer block will set the X bits (within each outbound DS3 frame) to the appropriate value, depending upon receive
conditions (as detected by the Receive DS3 Framer block).
` 1 - Forces the Transmit DS3 Framer block to transmit the DS3 FERF/RDI indicator. In this case, the Transmit DS3
Framer block will force the X bits (within each outbound DS3 frame) to 0.
NOTE: For normal operation (e.g., where the Transmit DS3 Framer Block will automatically transmit the FERF/RDI
indicator whenever the Receive DS3 Framer block declares either the LOS, AIS or LOF/OOF defect conditions)
the user MUST set this bit-field to 0.
BIT6 - Force X-Bits to 1
This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to set the X-bits (within each outbound DS3
frame) to 1.
` 0 - Configures the Transmit DS3 Framer block to automatically set the X bits to the appropriate value, depending upon
the receive conditions (as detected by the Receive DS3 Framer block).
` 1 - Configures the Transmit DS3 Framer block to force all of the X bits (within the outbound DS3 data-stream) to 1.
In this configuration setting, the Transmit DS3 Framer block will set all X bits to 1 independent of whether the Receive
DS3 Framer block is currently declaring any defect conditions.
NOTE: For normal operation (e.g., where the Transmit DS3 Framer block will automatically transmit the FERF/RDI
indicator whenever the Receive DS3 Framer block declares the LOS, AIS or LOF/OOF defect condition) the
user MUST set this bit-field to 0.
BIT 5 - Transmit DS3 Idle Signal
This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the DS3 Idle Signal pattern to
the remote terminal equipment, as described below.
` 0 - Configures the Transmit DS3 Framer block to transmit normal traffic to the remote terminal equipment.
` 1 - Configures the Transmit DS3 Framer block to transmit the DS3 Idle Pattern to the remote terminal equipment.
NOTES:
1.
This bit-field is ignored if Bits 3 (Transmit LOS Indicator) or 4 (Transmit AIS Indicator) are set to 1.
2. The exact pattern that the Transmit DS3 Framer block will transmit (whenever this bit-field is set to 1)
depends upon the contents within Bits 3 through 0 (Transmit DS3 Idle Pattern[3:0]) within the DS3 Framer
Block - Transmit DS3 Pattern Register (Address = 0x0E4C).
BIT 4 - Transmit AIS Indicator
This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the DS3 AIS indicator to the
remote terminal equipment as described below.
` 0 - Configures the Transmit DS3 Framer block to transmit normal traffic (based upon T1/E1 data that has been
multiplexed into a DS3 data-stream) to the remote terminal equipment.
` 1 - Configures the Transmit DS3 Framer block to transmit the DS3 AIS indicator to the remote terminal equipment.
NOTES:
208
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
1.
This bit-field is ignored if BIT 3 (Transmit LOS Indicator) is set to 1.
2. Whenever this bit-field is set to 1, the Transmit DS3 Framer block will either transmit a Framed repeating
1, 0, 1, 0, …. Pattern, or an Unframed All Ones pattern, depending upon the state of BIT7 (Transmit AIS Unframed All Ones), within the Transmit DS3 Pattern Register (Address = 0x0E4C).
BIT 3 - Transmit LOS Indicator
This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the LOS pattern to the remote
terminal equipment, as described below.
` 0 - Configures the Transmit DS3 Framer block to transmit normal traffic to the remote terminal equipment.
` 1 - Configures the Transmit DS3 Framer block to transmit the LOS pattern (e.g., either an All Zeros or All Ones
pattern, depending upon user configuration).
NOTE: Whenever this bit-field is set to 1, it will transmit either an All Zero pattern or an Unframed All Ones pattern,
depending upon the state of BIT 4 (Transmit LOS Pattern - All Ones Pattern) within the Transmit DS3 Pattern
Register (Address = 0x0E4C).
BIT 2 - Transmit FERF/RDI upon LOS
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to automatically transmit the FERF/RDI
indicator, anytime (and for the duration that) the Receive DS3 Framer block declares the LOS defect condition.
` 0 - Configures the Transmit DS3 Framer block to NOT automatically transmit the FERF/RDI indicator, whenever (and
for the duration that) the Receive DS3 Framer block declares the LOS defect condition.
` 1 - Configures the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, whenever (and for
the duration that) the Receive DS3 Framer block declares the LOS defect condition.
BIT 1 - Transmit FERF/RDI upon LOF/OOF:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to automatically transmit the FERF/RDI
indicator, anytime (and for the duration that) the Receive DS3 Framer block declares the OOF defect condition, as
described below.
` 0 - Configures the Transmit DS3 Framer block to NOT automatically transmit the FERF/RDI indicator, whenever (and
for the duration that) the Receive DS3 Framer block declares the OOF defect condition.
` 1 - Configures the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator whenever (and for
the duration that) the Receive DS3 Framer block declares the OOF defect condition.
BIT 0 - Transmit FERF/RDI upon AIS
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to automatically transmit the FERF/RDI
indicator, anytime (and for the duration that) the Receive DS3 Framer block declares the AIS defect condition, as
described below.
` 0 - Configures the Transmit DS3 Framer block to NOT automatically transmit the FERF/RDI indicator, whenever (and
for the duration that) the Receive DS3 Framer block declares the AIS defect condition.
` 1 - Configures the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, whenever (and for
the duration that) the Receive DS3 Framer block declares the AIS defect condition.
TABLE 280: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC CONFIGURATION & STATUS REGISTER (ADDRESS =
0X0E31)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit
FEAC
Interrupt
Enable
Transmit
FEAC
Interrupt
Status
Transmit
FEAC
Controller
Enable
Transmit
FEAC
Message
Transmit
FEAC
Busy
R/O
R/O
R/O
R/W
RUR
R/W
R/W
R/O
0
0
0
0
0
0
0
0
BIT [7:5] - Unused:
Please set these bits to [0, 0, 0] for normal operation.
BIT 4 - Transmit FEAC Interrupt Enable:
209
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This READ/WRITE bit-field is used to either enable or disable the Transmit FEAC Interrupt. If the user enables this
interrupt, then the Transmit FEAC Controller block (within the Transmit DS3 Framer block) will generate an interrupt,
once it has completed its 10th transmission of a given FEAC Message to the remote terminal equipment.
` 0 - Disables the Transmit FEAC Interrupt
` 1 - Enables the Transmit FEAC Interrupt.
NOTE: This bit-field is only active if the Transmit and Receive DS3 Framer blocks have been configured to support the
C-bit Parity Framing format.
BIT 3 - Transmit FEAC Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Transmit FEAC Controller block has generated the
Transmit FEAC interrupt since the last read of this register.
` 0 - Indicates that the Transmit FEAC Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Transmit FEAC Interrupt has occurred since the last read of this register.
BIT 2 - Transmit FEAC Controller Enable:
This READ/WRITE bit-field is used to either enable or disable the Transmit FEAC Controller, within the
Transmit DS3 Framer block.
` 0 - Disables the Transmit FEAC Controller block.
` 1 - Enables the Transmit FEAC Controller block
BIT 1 - Transmit FEAC Message:
` A 0 to 1 transition, within this bit-field configures the Transmit FEAC Controller block to begin its transmission of the
FEAC Message (which consists of the FEAC Code, as specified within the Transmit DS3 FEAC Register.
NOTE: The user is advised to perform a write operation that resets this bit-field back to 0, following execution of the
command to transmit a FEAC Message.
BIT 0 - Transmit FEAC Busy:
This READ-ONLY bit-field indicates whether or not the Transmit FEAC Controller block is currently busy transmitting a
FEAC Message to the remote terminal.
` 0 - Indicates that the Transmit FEAC Controller is NOT currently busy transmitting a given FEAC Message.
` 1 - Indicates that the Transmit FEAC Controller is currently busy transmitting a given FEAC Message to the remote
terminal equipment.
TABLE 281: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC REGISTER (ADDRESS = 0X0E32)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
TxFEAC_Code[5:0]
BIT 0
Unused
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/O
0
1
1
1
1
1
1
0
BIT 7 - Unused:
BIT [6:1] - TxFEAC_Code[5:0]:
These six (6) READ/WRITE bit-fields permit the user to specify the FEAC Code word that the Transmit FEAC Controller
block (within the Transmit DS3 Framer block) should transmit to the remote terminal equipment.
Once the user enables the Transmit FEAC Controller and commands it to begin its transmission, the Transmit FEAC
Controller will then (1) encapsulate this six-bit code word into a 16-bit structure, and (2) proceed to transmit this 16-bit
structure 10 times, repeatedly, and then halt.
NOTE: These bit-fields are ignored if the user does not enable and use the Transmit FEAC Controller.
BIT 0 - Unused:
210
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 282: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD CONFIGURATION REGISTER (ADDRESS = 0X0E33)
BIT 7
BIT 6
Transmit
LAPD Any
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Auto
Retransmit
Reserved
Transmit
LAPD Message Length
Transmit
LAPD Controller Enable
R/W
R/O
R/O
R/O
R/W
R/O
R/W
R/W
0
0
0
0
1
0
0
0
BIT 7 - Transmit LAPD Any:
This READ/WRITE bit-field is used to configure the Transmit LAPD Controller block to transmit any kind of LAPD
Message (or HDLC Message) with a size of 82 bytes or less. If the user implements this option, then the Transmit LAPD
Controller block will be capable of transmitting any kind of HDLC frame (with any value of header bytes). The only
restriction is that the size of the HDLC frame must not exceed 82 bytes.
` 0 - Does not invoke this Any Kind of HDLC Message feature. In this case, the Transmit LAPD Controller block will
only transmit HDLC Messages that contains the Bellcore GR-499-CORE values for SAPI and TEI.
` 1 - Invokes this Any Kind of HDLC Message feature. In this case, the Transmit LAPD Controller block will be able to
transmit HDLC Messages that contains any header byte values.
NOTE: If the Any Kind of HDLC Message feature is invoked, then the size of the information payload (in terms of bytes)
within the Transmit LAPD byte Count Register Address = 0x0E83) must be indicated.
BIT [6:4] - Unused:
BIT 3 - Auto Retransmit
This READ/WRITE bit-field is used to configure the Transmit LAPD Controller block to transmit PMDL messages,
repeatedly at one-second intervals. Once the user enables this feature, and then commands the Transmit LAPD
Controller block to transmit a given PMDL Message, then the Transmit LAPD Controller block will then proceed to
transmit this PMDL Message (based upon the contents within the Transmit LAPD Message Buffer) repeatedly at one
second intervals.
` 0 - Disables the Auto-Retransmit Feature:
In this case, the Transmit LAPD Controller block will only transmit a given PMDL Message once. Afterwards the
Transmit LAPD Controller block will proceed to transmit a continuous stream of Flag Sequence octets (0x7E) via the
DL bits, within each output DS3 frame. No more PMDL Messages will be transmitted until the user commands another
transmission.
` 1 - Enables the Auto-Retransmit Features
In this case, the Transmit LAPD Controller block will transmit PMDL messages (based upon the contents within the
Transmit LAPD Message buffer) repeatedly at one-second interval.s
NOTE: This bit-field is ignored if the Transmit LAPD Controller block is disabled.
BIT 2 - Reserved:
BIT 1 - Transmit LAPD Message Length:
This READ/WRITE bit-field is used to specify the length of the payload data within the outbound LAPD/PMDL Message,
as indicated below.
` 0 - Configures the Transmit LAPD Controller block to transmit a LAPD/PMDL Message that has a payload data size
of 76 bytes.
` 1 - Configures the Transmit LAPD Controller block to transmit a LAPD/PMDL Message that has a payload data size
of 82 bytes.
BIT 0 - Transmit LAPD Controller Enable:
This READ/WRITE bit-field is used to enable the Transmit LAPD Controller block within the chip. Once the user enables
the Transmit LAPD Controller block, it will immediately begin transmitting the Flag Sequence octet (0x7E) to the remote
terminal via the DL within the outbound DS3 data-stream. The Transmit LAPD Controller block will continue to do this
until the user commands the Transmit LAPD Controller block to transmit a PMDL Message.
` 0 - Disables the Transmit LAPD Controller block.
211
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 1 - Enables the Transmit LAPD Controller block.
TABLE 283: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD STATUS/INTERRUPT REGISTER (ADDRESS = 0X0E34)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Transmit
LAPD Message Start
Transmit
LAPD Controller Busy
Transmit
LAPD Interrupt Enable
Transmit
LAPD Interrupt Status
R/O
R/O
R/O
R/O
R/W
R/O
R/W
RUR
0
0
0
0
0
0
0
0
BIT [7:4] - Unused:
BIT 3 - Transmit LAPD Message Start:
` A 0 to 1 transition within this bit-field commands the Transmit LAPD Controller block to begin the following activities.
•
Reading out the contents of the Transmit LAPD Message buffer.
•
Zero-stuffing of this data
•
FCS Calculation and Insertion
•
Fragmentation of this composite PMDL Message, and insertion into the DL bit-fields, within each outbound
DS3 frame.
BIT 2 - Transmit LAPD Controller Busy:
This READ-ONLY bit-field indicates whether or not the Transmit LAPD Controller block is currently busy transmitting a
PMDL Message to the remote terminal equipment. The user can continuously poll this bit-field in order to check for
completion of transmission of the LAPD/PMDL Message.
` 0 - Indicates that the Transmit LAPD Controller block is NOT currently busy transmitting a PMDL message.
` 1 - Indicates that the Transmit LAPD Controller block is currently busy transmitting a PMDL message.
BIT 1 - Transmit LAPD Message Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Transmit LAPD Message Interrupt. If the user enables
this interrupt, then the Transmit DS3 Framer block will generate an interrupt anytime the Transmit LAPD Controller block
has completed its transmission of a given LAPD/PMDL Message to the remote terminal.
` 0 - Disables the Transmit LAPD Message Interrupt.
` 1 - Enables the Transmit LAPD Message Interrupt.
BIT 0 - Transmit LAPD Message Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Transmit LAPD Message Interrupt has occurred since
the last read of this register.
` 0 - Indicates that the Transmit LAPD Message Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the Transmit LAPD Message Interrupt has occurred since the last read of this register.
TABLE 284: DS3 FRAMER BLOCK - TRANSMIT DS3 M-BIT MASK REGISTER (ADDRESS = 0X0E35)
BIT7
BIT6
BIT 5
TxFEBEDat[2:0]
BIT 4
BIT 3
FEBE Register Enable
Transmit PBit Error
BIT 2
BIT 1
BIT 0
TxM_Bit_Mask[2:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 5 - TxFEBEDat[2:0]
These READ/WRITE bit-fields, along with BIT 4 (FEBE Register Enable) are used to configure the Transmit DS3 Framer
block to transmit the user-specified FEBE values (to the remote terminal equipment) based upon the contents of these
bit-fields.
212
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
If the user sets the FEBE Register Enable bit-field to '1, then the Transmit DS3 Framer block will wsrite the contents of
these bit-fields into the FEBE bit-fields within each outbound DS3 frame.
If the user sets the FEBE Register Enable bit-field to 0, then these register bits will be ignored.
BIT 4 - FEBE Register Enable
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit user-specified FEBE values
(to the remote terminal equipment) per register setting via the TxFEBEDat[2:0] bit-fields. This option is used to exercise
software control over the outbound FEBE values, within the outbound DS3 data-stream.
` 0 - Configures the Transmit DS3 Framer block to set the FEBE bit-fields (within each outbound DS3 frame) to the
appropriate values based upon receive conditions, as determined by the Receive DS3 Framer block.
` 1 - Configures the Transmit DS3 Framer block to set the write the contents of the TxFEBEDat[2:0] bit-fields into the
FEBE bit-positions within each outbound DS3 frame.
BIT 3 - Transmit P-Bit Error
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with erred Pbits as indicated below.
` 0 - Configures the Transmit DS3 Framer block to generate and transmit DS3 frames (with correct P-bit values) to the
remote terminal equipment.
` 1 - Configures the Transmit DS3 Framer block to generate and transmit DS3 frames (with erred P-bit values) to the
remote terminal equipment.
BIT[2:0] - TxM_Bit_Mask[2:0]
These READ/WRITE bit-fields are used to configure the Transmit DS3 Framer block to transmit DS3 frames with erred
M-bits.
These three (3) bit-fields corresponding to each of the three M-bits, within each outbound DS3 frame. The Transmit
DS3 Framer block will perform an XOR operation with the contents of these bit-fields and the values of the three M-bits.
The results of this calculation will be written back into the M-bit position within each outbound DS3 frame.
NOTE: The user should set these bit-fields to 0, 0, 0 for normal (e.g., un-erred) operation.
TABLE 285: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTERS # 1 (ADDRESS = 0X0E36)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
F-Bit
Mask[27]
F-Bit
Mask[26]
F-Bit
Mask[25]
F-Bit
Mask[24]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT[7:4] - Unused
BIT 3 - F-Bit Mask[27]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 28th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 28th F-bit. The results of this
calculation will be written back into the 28th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 2 - F-Bit Mask[26]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 27th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 27th F-bit. The results of this
calculation will be written back into the 27th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 1 - F-Bit Mask[25]:
213
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 26th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 26th F-bit. The results of this
calculation will be written back into the 26th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 0 - F-Bit Mask[24]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 25th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 25th F-bit. The results of this
calculation will be written back into the 25th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
TABLE 286: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 2 (ADDRESS = 0X0E37)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
F-Bit
Mask[23]
F-Bit
Mask[22]
F-Bit
Mask[21]
F-Bit
Mask[20]
F-Bit
Mask[19]
F-Bit
Mask[18]
F-Bit
Mask[17]
F-Bit
Mask[16]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - F-Bit Mask[23]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 24th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 24th F-bit. The results of this
calculation will be written back into the 24th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT6 - F-Bit Mask[22]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 23rd F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 23rd F-bit. The results of this
calculation will be written back into the 23rd F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 5 - F-Bit Mask[21]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 22nd F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 22nd F-bit. The results of this
calculation will be written back into the 22nd F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 4 - F-Bit Mask[20]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 21st F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 21st F-bit. The results of this
calculation will be written back into the 21st F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 3 - F-Bit Mask[19]:
214
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 20th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 20th F-bit. The results of this
calculation will be written back into the 20th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 2 - F-Bit Mask[18]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 19th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 19th F-bit. The results of this
calculation will be written back into the 19th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 1 - F-Bit Mask[17]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 18th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 18th F-bit. The results of this
calculation will be written back into the 18th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
BIT 0 - F-Bit Mask[16]:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a
single/particular erred F-bit.
This particular F-bit corresponds with the 17th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer
block will perform an XOR operation with the contents of this bit-field and the value of the 17th F-bit. The results of this
calculation will be written back into the 17th F-bit position, within each outbound DS3 frame.
NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation.
TABLE 287: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 3 (ADDRESS = 0X0E38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
F-Bit
Mask[15]
F-Bit
Mask[14]
F-Bit
Mask[13]
F-Bit
Mask[12]
F-Bit
Mask[11]
F-Bit
Mask[10]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
F-Bit Mask[9] F-Bit Mask[8]
BIT [7:0] - See Table 286 above, for bit descriptions, substituting Mask [15:8] for mask[23:16]
TABLE 288: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 4 (ADDRESS = 0X0E39)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
F-Bit Mask[7] F-Bit Mask[6] F-Bit Mask[5] F-Bit Mask[4] F-Bit Mask[3] F-Bit Mask[2] F-Bit Mask[1] F-Bit Mask[0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 286 above, for bit descriptions, substituting Mask [7:0] for mask[23:16]
215
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 289: DS3 FRAMER BLOCK - M12 DS2 # 1 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747
FAS Bit
Error Count
DS2 LOF - M
Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT 7 - Unused:
BIT 6 - One and Only:
This READ/WRITE bit-field is used to select the F-bit acquisition criteria that the M12 DeMUX block will use, whenever
it is operating in the F-Bit Search state, as described below.
` 0 - Configures the M12 De-MUX block to move onto the M-Bit Search state, whenever it has properly located 8 (or
16) consecutive F-bits (as configured in Bit 4 of this register).
` 1 - Configures the M12 De-MUX block to move onto the M-Bit Search state, whenever it has (1) properly located 8
(or 16) consecutive F-bits and (2) when it has located and identified only one viable F-Bit Alignment candidate.
NOTE: If the user sets this bit-field to 1, then the M12 De-MUX block will NOT transition into the M-Bit Search state as
long as at least two viable candidate sets of bits appears to function as the F-bits.
BIT 5 - DS2 M-Sync:
This READ/WRITE bit-field is used to select the M-Bit Acquisition criteria whenever the M12 De-MUX block is operating
in the M-Bit Search state.
` 0 - Configures the M12 De-MUX block to declare the In-Frame state, when it has properly located 4 consecutive Mbits (while detecting no F-bit errors).
` 1 - Configures the M12 De-MUX block to declare the In-Frame state, when it has properly located 8 consecutive Mbits (while detecting no F-bit errors).
BIT 4 - DS2 F-Sync:
This READ/WRITE bit-field is used to select the F-Bit Acquisition criteria whenever the M12 De-MX block is operating
in the F-Bit Search state.
` 0 - Configures the M12 De-MUX block to move onto the M-Bit Search state, when it has properly located 8
consecutive F-bits.
` 1 - Configures the M12 De-MUX block to move onto the M-Bit Search state, when it has properly located 16
consecutive F-bits.
BIT 3 - DS2 LOF - F Bits/G.747 FAS Bit Error Count
The exact function of this bit-field depends upon whether the M12 MUX/De-MUX block has been configured to operate
in the DS2 or in the G.747 Mode, as described below.
If M12 MUX/M12 De-MUX # 1 is configured to operate in the DS2 Mode:
This READ/WRITE bit-field is used to select the F-Bit LOF (Loss of Frame) Defect criteria for the M12 De-MUX
associated with DS2 Channel 1.
` 0 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition whenever the M12 De-MUX block
detects two (2) F-bit errors within the four (4) most recently received F-bits within the incoming DS2 data-stream.
` 1 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition whenever the M12 De-MUX defect
two (2) F-bit errors within the five (5) most recently received F-bits within the incoming DS2 data-stream.
If M12 MUX/M12 De-MUX # 1 is configured to operate in the G.747 Mode:
This READ/WRITE bit-field is used to specify how the M12 De-MUX increments G.747 Framing Alignment Signal (FAS)
errors.
The user can configure the M12 De-MUX to increment the PMON DS2 # 1 Framing Bit Error Count Register on either
216
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
a per-bit or per-frame basis, as described below.
Per-Bit Basis:
The M12 De-MUX will increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count Register once for
each bit-error that it detects within the FAS bit-fields of the incoming G.747 data-stream.
Per-Frame Basis:
The M12 De-MUX will increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count Register once for
each time it detects at least one bit-error within the FAS bit-fields of a given incoming G.747 frame.
` 0 - Configures the M12 De-MUX to increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count
Register on a per-bit basis.
` 1 - Configures the M12 De-MUX block to increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count
Register on a per-frame basis.
BIT 2 - DS2 LOF - M Bits
This READ/WRITE bit-field is used to select the M-Bit LOF (Loss of Frame) Defect criteria for the M12 De-MUX block
associated with DS2 Channel 1.
` 0 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition whenever the M12 De-MUX block
detects M-bit errors within three (3) out of the four (4) most recently received DS2 M-frames.
` 1 - Configures the M12 De-MUX block to declares the DS2 LOF defect condition whenever the M12 De-MUX block
detects M-bit errors within two (2) out of the four (4) most recently received DS2 M-frames.
BIT 1 - DS2 LOF - M Bits Disable
This READ/WRITE bit-field is used to configure the M12 De-MUX block to not use M-bit errors as a reason/criteria for
declaring the DS2 LOF defect condition.
` 0 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition, based upon the number of M-bit
errors (as selected in Bit 2 within this register).
` 1 - Configures the M12 De-MUX block to NOT declare the DS2 LOF defect condition, based upon the occurrences
of any M-bit errors.
BIT 0 - DS2 Reframe:
` A 0 to 1 transition, within this bit-field commands the M12 De-MUX block to exit the Frame Maintenance mode, and
go back and enter the Frame Acquisition Mode.
NOTE: The user should go back and set this bit-field to 0 following execution of the Reframe Command.
TABLE 290: DS3 FRAMER BLOCK - M12 DS2 # 2 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747 FAS
Bit Error
Count
DS2 LOF
- M Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit [7:0] - See bit description for Table 289, above.
217
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 291: DS3 FRAMER BLOCK - M12 DS2 # 3 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747 FAS
Bit Error
Count
DS2 LOF
- M Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit [7:0] - See bit description for Table 289, above.
TABLE 292: DS3 FRAMER BLOCK - M12 DS2 # 4 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747 FAS
Bit Error
Count
DS2 LOF
- M Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit [7:0] - See bit description for Table 289, above.
TABLE 293: DS3 FRAMER BLOCK - M12 DS2 # 5 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747 FAS
Bit Error
Count
DS2 LOF
- M Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit [7:0] - See bit description for Table 289, above.
218
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 294: DS3 FRAMER BLOCK - M12 DS2 # 6 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747 FAS
Bit Error
Count
DS2 LOF
- M Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit [7:0] - See bit description for Table 289, above.
TABLE 295: DS3 FRAMER BLOCK - M12 DS2 # 7 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E40)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
One and
Only
DS2 M-Sync
DS2 F-Sync
DS2 LOF
- F Bits/
G.747 FAS
Bit Error
Count
DS2 LOF
- M Bits
DS2 LOF
- M Bits
Disable
DS2
Reframe
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit [7:0] - See bit description for Table 289, above.
TABLE 296: DS3 FRAMER BLOCK - TRANSMIT DS3 PATTERN REGISTER (ADDRESS = 0X0E4C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit AIS
- Unframed
All Ones
Transmit AIS
- C bits not
forced to 0
Transmit AIS
- Ignore
Overhead
Data from
TxDS3OH
Port
Transmit
LOS Pattern
- All Ones
Pattern
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
1
1
0
0
DS3 Idle Pattern[3:0]
BIT7 - Transmit AIS - Unframed All Ones:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit either of the following
patterns, anytime it is configured to transmit the AIS indicator.
•
A Framed, repeating 1, 0, 1, 0… pattern (per Bellcore GR-499-CORE) or
•
An Unframed All Ones Pattern.
` 0 - Configures the Transmit DS3 Framer block to transmit the Framed, Repeating 1, 0, 1, 0,… Pattern, whenever it is
configured to transmit the AIS Indicator.
` 1 - Configures the Transmit DS3 Framer block to transmit an Unframed, All Ones Pattern, whenever it is configured
to transmit the AIS indicator.
BIT6 - Transmit AIS - C Bits NOT forced to 0
219
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This READ/WRITE bit-field (along with the Transmit AIS - Unframed All Ones bit-field) is used to define the type of AIS
data-stream that the Transmit DS3 Framer block will transmit, as described below.
` 0 - Configures the Transmit DS3 Framer block to force all of the C bits to 0 when it is configured to transmit a Framed
AIS signal.
` 1 - Configures the Transmit DS3 Framer block to NOT force all of the C bits to 0 when it is configured to transmit a
Framed AIS signal. In this case, the C bits can be used to transport FEAC or PMDL Messages.
NOTE: This bit-field is ignored if the Transmit DS3 Framer block has been configured to transmit an Unframed - All
Ones type of AIS signal.
BIT 5 - Transmit AIS - Ignore Overhead Data from TxDS3OH Port
This READ/WRITE bit-field permits the Transmit DS3 Framer block to either accept or ignore externally supplied DS3
Overhead data, whenever it (the Transmit DS3 Framer block) is transmitting the AIS indicator.
If this feature is used, then (for the duration that the Transmit DS3 Framer block is commanded to transmit the DS3 AIS
indicator) the Transmit DS3 Framer block will NOT allow the users to externally insert their DS3 OH bits within the
outbound DS3 data-stream, even if the TxOH Source bit-field is set to 1 and if the corresponding F-Bit Mask bit-field is
set to 0.
Conversely, if the user does NOT use this feature, then the Transmit DS3 Framer block will allow the users to externally
insert theirr own DS3 OH bits (within the outbound DS3 data-stream) even when the Transmit DS3 Framer block is
transmitting the DS3 AIS indicator to the remote terminal equipment.
` 0 - Does NOT invoke the Ignore TxDS3OH Port During AIS Feature
` 1 - Invokes the Ignore the TxDS3OH Port During AIS feature.
BIT 4 - Transmit LOS Pattern Select:
This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit either an All Zeros or an All
Ones pattern, anytime it is configured to transmit the LOS Pattern to the remote terminal equipment, as described below.
` 0 - Configures the Transmit DS3 Framer block to transmit an All Zeros pattern whenever it is configured to transmit
the LOS pattern.
` 1 - Configures the Transmit DS3 Framer block to transmit an All Ones pattern whenever it is configured to transmit
the LOS pattern.
BIT[3:0] - Transmit DS3 Idle Pattern[3:0]
These READ/WRITE bit-fields are used to specify the type of framed, repetitive four-bit pattern that the Transmit DES3
Framer block should generate and transmit, whenever it is configured to transmit the DS3 Idle Pattern.
NOTE: Setting these bit-fields to [1, 1, 0, 0] configures the Transmit DS3 Framer block to transmit the standard
Framed, repeating 1, 1, 0, 0, … pattern (per Bellcore GR-499-CORE) requirements.
TABLE 297: DS3 FRAMER BLOCK - AUTO T1/E1 AIS UPON DS3 DEFECT CONDITION REGISTER (ADDRESS =
0X0E4D)
BIT7
BIT6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Auto
DS1/E1AIS
upon DS3
LOS Defect
Unused
Auto DS1/E1
AIS upon
DS3 OOF
Defect
Unused
Auto DS1/E1
AIS upon
DS3 AIS
Defect
R/O
R/O
R/O
R/W
R/O
R/W
R/O
R/W
0
0
0
0
0
0
0
0
Bits 7 - 5 - Unused
BIT 4 - Auto DS1/E1 AIS upon DS3 LOS Defect
This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (within the
XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via the downstream DS1/E1 signals, anytime (and for
the duration that) the Receive DS3 Framer block declares the LOS defect condition.
` 0 - Does not configure all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS
indicators via the downstream DS1/E1 signals, anytime the Receive DS3 Framer block declares the LOS defect
220
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
condition.
` 1 - Configures all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS
indicators via the downstream DS1/E1 signals anytime the Receive DS3 Framer block declares the LOS defect
condition.
NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in either the M13 MUX or the
M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode.
BIT 3 - Unused
BIT 2 - Auto DS1/E1 AIS upon DS3 OOF Defect
This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (within the
XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via the downstream DS1/E1 signals, anytime (and for
the duration that) the Receive DS3 Framer block declares the LOF/OOF defect condition.
` 0 - Does not configure all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS
indicators via the downstream DS1/E1 signals, anytime the Receive DS3 Framer block declares the LOF/OOF defect
condition.
` 1 - Configures all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS
indicators via the downstream DS1/E1 signals anytime the Receive DS3 Framer block declares the LOF/OOF defect
condition.
NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in either the M13 MUX or the
M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode.
BIT 1 - Unused
BIT 0 - Auto DS1/E1 AIS upon DS3 AIS Defect
This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (within the
XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via the downstream DS1/E1 signals, anytime (and for
the duration that) the Receive DS3 Framer block declares the AIS defect condition.
` 0 - Does not configure all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS
indicators via the downstream DS1/E1 signals, anytime the Receive DS3 Framer block declares the AIS defect
condition.
` 1 - Configures all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS
indicators via the downstream DS1/E1 signals anytime the Receive DS3 Framer block declares the AIS defect
condition.
NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in either the M13 MUX or the
M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode.
TABLE 298: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - MSB (ADDRESS =
0X0E4E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON EXZ Event Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON EXZ_Event_Count[15:8]:
These RESET-upon-READ bits, along with that within the PMON Excessive Zero Count Register - LSB combine to
reflect the cumulative number of instances in which the Receive DS3 Framer block has detected a string of three or
more consecutive zeros within the incoming DS3 data-stream, since the last read of this register.
This register contains the Most Significant Byte of this 16-bit expression.
221
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 299: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - LSB (ADDRESS =
0X0E4F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON EXZ Event Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON EXZ_Event_Count[7:0]:
These RESET-upon-READ bits, along with that within the PMON Excessive Zero Count Register -MSB combine to
reflect the cumulative number of instances in which the Receive DS3 Framer block has detected a string of three or
more consecutive zeros within the incoming DS3 data-stream, since the last read of this register.
This register contains the Least Significant Byte of this 16-bit expression.
TABLE 300: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - MSB
(ADDRESS = 0X0E50)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON LCV Event Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON LCV_Event_Count[15:8]:
These RESET-upon-READ bits along with that within the PMON Line Code Violation Count - LSB register combine to
reflect the cumulative number of Line Code Violation events that the Receive DS3 Framer block has detected within the
incoming DS3 data-stream, since the last read of this register.
This register contains the Most Significant byte of this 16-bit expression.
TABLE 301: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - LSB
(ADDRESS = 0X0E51)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON LCV Event Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON LCV_Event_Count[7:0]:
These RESET-upon-READ bits along with that within the PMON Line Code Violation Count - MSB register combine to
reflect the cumulative number of Line Code Violation events that the Receive DS3 Framer block has detected within the
incoming DS3 data-stream, since the last read of this register.
This register contains the Least Significant byte of this 16-bit expression.
TABLE 302: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E52)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_Framing_Bit_Error_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
222
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT [7:0]: PMON Framing Bit ErrorCount[15:8]:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON Framing Bit Error Count Register
- LSB combine to reflect the cumulative number of Framing bit errors that the Receive DS3 Framer block has detected
since the last read of this register. This register contains the Most Significant byte of this 16-bit expression.
NOTE: The Receive DS3 Framer block will increment this register each time that it detects F or M bit errors within the
incoming DS3 data-stream.
TABLE 303: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E53)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_Framing_Bit_Error_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0]: PMON Framing Bit ErrorCount[7:0]:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON Framing Bit Error Count Register
- MSB combine to reflect the cumulative number of Framing bit errors that the Receive DS3 Framer block has detected
since the last read of this register. This register contains the Least Significant byte of this 16-bit expression.
NOTE: The Receive DS3 Framer block will increment this register each time that it detects F or M bit errors within the
incoming DS3 data-stream.
TABLE 304: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E54)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_P_Bit _Error_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0]: PMON P-Bit Error Count[15:8]:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON P-bit Error Count Register - LSB
combine to reflect the cumulative number of P-bit errors that the Receive DS3 Framer block has detected within the
incoming DS3 data-stream, since the last read of this register. This register contains the Most Significant byte of this
16-bit expression.
TABLE 305: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E55)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_P_Bit_Error_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON P-Bit Error Count[7:0]:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON P-bit Error Count Register - MSB
combine to reflect the cumulative number of P-bit errors that the Receive DS3 Framer block has detected within the
incoming DS3 data-stream, since the last read of this register. This register contains the Least Significant byte of this
16-bit expression.
223
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 306: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E56)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_FEBE_Event_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON FEBE Event Count[15:8]:
These RESET-upon-READ bits, along with that within the PMON FEBE Event Count Register - LSB combine to reflect
the cumulative number of FEBE/REI events that the Receive DS3 Framer block has detected within the incoming DS3
data-stream, since the last read of this register. This register contains the Most Significant byte of this 16-expression.
TABLE 307: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E57)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_FEBE_Event_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON FEBE Event Count[7:0]:
These RESET-upon-READ bits, along with that within the PMON FEBE Event Count Register - MSB combine to reflect
the cumulative number of FEBE/REI events that the Receive DS3 Framer block has detected within the incoming DS3
data-stream, since the last read of this register. This register contains the Least Significant byte of this 16-expression.
TABLE 308: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E58)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_CP_Bit_Error_Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON CP-Bit Error Count[15:8]:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON CP-Bit Error Count Register - LSB
combine to reflect the cumulative number of CP bit errors that the Receive DS3 Framer block has detected since the
last read of this register. This register contains the Most Significant byte of this 16-bit expression.
NOTE: These register bits are not active if the Transmit and Receive DS3 Framer blocks have NOT been configured to
support the DS3 C-bit Parity Framing format.
TABLE 309: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E59)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_CP_Bit_Error_Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON CP-Bit Error Count[7:0]:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON CP-Bit Error Count Register MSB combine to reflect the cumulative number of CP bit errors that the Receive DS3 Framer block has detected since
the last read of this register. This register contains the Least Significant byte of this 16-bit expression.
224
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: These register bits are not active if the Transmit and Receive DS3 Framer blocks have NOT been configured to
support the DS3 C-bit Parity Framing format.
TABLE 310: DS3 FRAMER BLOCK - PMON DS2 # 1 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5A)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 1 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON DS2 # 1 - Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]:
The function of this bit-field depends upon whether M12 MUX/De-MUX # 1 has been configured to operate in the DS2
or in the G.747 Mode.
If M12 MUX/De-MUX # 1 has been configured to operate in the DS2 Mode:
These RESET-upon-READ bit-fields reflects the cumulative number of F and M bit errors that the M12 De-MUX Block
(associated with DS2 Channel 1) has detected since the last read of this register.
If M21 MUX/De-MUX # 1 has been configured to operate in the G.747 Mode:
This RESET-upon-READ bit-fields reflects the cumulative number of FAS errors that the M12 De-MUX block
(associated with DS2 Channel 1) has detected since the last read of this register.
TABLE 311: DS3 FRAMER BLOCK - PMON DS2 # 2 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5B)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 2 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] See Figure 310 above, for bit descriptions
TABLE 312: DS3 FRAMER BLOCK - PMON DS2 # 3 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 3 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] See Figure 310 above, for bit descriptions
TABLE 313: DS3 FRAMER BLOCK - PMON DS2 # 4 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 4 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] See Figure 310 above for bit descriptions
225
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 314: DS3 FRAMER BLOCK - PMON DS2 # 5 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 5 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] See Figure 310 above, for bit descriptions
TABLE 315: DS3 FRAMER BLOCK - PMON DS2 # 6 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 6 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] See Figure 310 above, for bit descriptions
TABLE 316: DS3 FRAMER BLOCK - PMON DS2 # 7 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E60)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_DS2 # 7 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] See Figure 310 above for bit descriptions
TABLE 317: DS3 FRAMER BLOCK - PMON G.747 # 1 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E61)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 1 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PMON G.747 # 1 - Parity Error Count[7:0]:
This RESET-upon-READ bit-field reflects the cumulative number of P-bit errors that the M12 De-MUX Block
(associated with G.747 Channel # 1) has detected since the last read of this register.
NOTE: These bit-fields are only active if M12 MUX/De-MUX # 1 has been configured to operate in the G.747 Mode.
TABLE 318: DS3 FRAMER BLOCK - PMON G.747 # 2 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E62)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 2 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 2 for Channel # 1.
226
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 319: DS3 FRAMER BLOCK - PMON G.747 # 3 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E63)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 3 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 3 for Channel # 1.
TABLE 320: DS3 FRAMER BLOCK - PMON G.747 # 4 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E64)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 4 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 4 for Channel # 1.
TABLE 321: DS3 FRAMER BLOCK - PMON G.747 # 5 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E65)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 5 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 5 for Channel # 1.
TABLE 322: DS3 FRAMER BLOCK - PMON G.747 # 6 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E66)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 6 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 6 for Channel # 1.
TABLE 323: DS3 FRAMER BLOCK - PMON G.747 # 7 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E67)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PMON_G.747 # 7 - Parity Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 7 for Channel # 1.
227
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 324: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E68)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PRBS Error Count[15:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PRBS Error Count - Upper Byte:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PRBS Bit Error Count Register - LSB
combine to reflect the cumulative number of PRBS bit errors that the PRBS Receiver (within the Receive DS3 Framer
block) has detected since the last read of this register. This register contains the Most Significant byte of this 16-bit
expression.
NOTE: This register is only active of the PRBS Receiver (within the Receive DS3 Framer block) has been enabled.
TABLE 325: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E69)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PRBS Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - PRBS Error Count - Lower Byte:
These RESET-upon-READ bits, along with that within the DS3 Framer Block - PRBS Bit Error Count Register - MSB
combine to reflect the cumulative number of PRBS bit errors that the PRBS Receiver (within the Receive DS3 Framer
block) has detected since the last read of this register. This register contains the Least Significant byte of this 16-bit
expression.
NOTE: This register is only active of the PRBS Receiver (within the Receive DS3 Framer block) has been enabled.
TABLE 326: DS3 FRAMER BLOCK - ONE SECOND ERROR STATUS REGISTER (ADDRESS = 0X0E6D)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Erred
Second
Severely
Erred
Second
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:2] - Unused:
BIT 1 - Erred Second:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block has declared the last one-second
accumulation period as an Erred Second.
The Receive DS3 Framer block will declare an Erred Second if it detects any of the following events, within a given onesecond period.
•
P-Bit Errors
•
CP-Bit Errors
•
Framing Bit (F or M) Errors
` 0 - Indicates that the Receive DS3 Framer block has NOT declared the last one-second accumulation period as being
an Erred Second.
228
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 1 - Indicates that the Receive DS3 Framer block has declared the last one-second accumulation period as being an
Erred Second.
BIT 0 - Severely Erred Second:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block has declared the last onesecond accumulation period as being a Severely Erred Second.
The Receive DS3 Framer block will declares a given one-second period as being a severely erred second if it
determines that the BER (Bit Error Rate) during this one-second accumulation period is greater than 10-3
errors/second.
` 0 - Indicates that the Receive DS3 Framer block has NOT declared the last one-second accumulation period as being
a severely-erred second.
` 1 - Indicates that the Receive DS3 Framer block has declared the last one-second accumulation period as being a
severely-erred second.
TABLE 327: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E6E)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
One_Second_LCV_Accum_Count[15:8]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - One-Second LCV Accumulation Count[15:8]:
These READ-ONLY bits, along with that within the DS3 Framer Block - One Second LCV Accumulation Count Register
- MSB combine to reflect the cumulative number of Line Code Violations that the Receive DS3 Framer block has
detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains
the Most Significant byte of this 16-bit expression.
NOTE: This register is only active if the XRT86SH328 has been configured to operate in the M13 MUX Mode.
TABLE 328: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E6F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
One_Second_LCV_Accum_Count[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - One-Second LCV Accumulation Count[7:0]:
These READ-ONLY bits, along with that within the DS3 Framer Block - One Second LCV Accumulation Count Register
- LSB combine to reflect the cumulative number of Line Code Violations that the Receive DS3 Framer block has
detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains
the Least Significant byte of this 16-bit expression.
NOTE: This register is only active if the XRT86SH328 has been configured to operate in the M13 MUX Mode.
TABLE 329: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS =
0X0E70)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
One_Second_P_Bit_Error_Accum_Count[15:8]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - One-Second P-Bit Error Accumulation Count[15:8]:
229
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
These READ-ONLY bits, along with that within the DS3 Framer Block - One Second P-Bit Error Accumulation Count
Register - LSB combine to reflect the cumulative number of P-Bit errors that the Receive DS3 Framer block has detected
within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Most
Significant byte of this 16-bit expression.
TABLE 330: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS =
0X0E71)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
One_Second_P_Bit_Error_Accum_Count[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - One-Second P-Bit Error Accumulation Count[7:0]:
These READ-ONLY bits, along with that within the DS3 Framer Block - One Second P-Bit Error Accumulation Count
Register - MSB combine to reflect the cumulative number of P-Bit errors that the Receive DS3 Framer block has
detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains
the Least Significant byte of this 16-bit expression.
TABLE 331: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS =
0X0E72)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
One_Second_CP_Bit_Error_Accum_Count[15:8]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - One-Second CP-Bit Error Accumulation Count[15:8]:
These READ-ONLY bits, along with that within the DS3 Framer Block - One Second CP-Bit Error Accumulation Count
Register - LSB combine to reflect the cumulative number of CP-Bit errors that the Receive DS3 Framer block has
detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains
the Most Significant byte of this 16-bit expression.
NOTE: This register is only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in
the DS3, C-bit Parity Framing format.
TABLE 332: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS =
0X0E73)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
One_Second_CP_Bit_Error_Accum_Count[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - One-Second CP-Bit Error Accumulation Count[7:0]:
These READ-ONLY bits, along with that within the DS3 Framer Block - One Second CP-Bit Error Accumulation Count
Register - MSB combine to reflect the cumulative number of CP-Bit errors that the Receive DS3 Framer block has
detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains
the Least Significant byte of this 16-bit expression.
NOTE: This register is only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in
the DS3, C-bit Parity Framing format.
230
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 333: DS3 FRAMER BLOCK - TRANSMIT LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E83)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Tx_LAPD_MESSAGE_SIZE[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - Transmit LAPD Message Size[7:0]:
These READ/WRITE bit-fields permit the user to specify the size of the information payload (in terms of bytes) within
the very next outbound LAPD/PMDL Message whenever Bit 7 (Transmit LAPD Any) within the DS3 Framer Block Transmit LAPD Configuration Register has been set to 1.
TABLE 334: DS3 FRAMER BLOCK - RECEIVE LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E84)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Rx_LAPD_MESSAGE_SIZE[7:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Receive LAPD Message Size[7:0]:
These READ-ONLY bit-fields indicate the size of the most recently received LAPD/PMDL Message, whenever Bit 7
(Receive LAPD Any) within the DS3 Framer Block - Receive LAPD Control Register has been set to 1.
The contents of this register reflect the Receive LAPD Message size, in terns of bytes.
TABLE 335: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT ENABLE REGISTER (ADDRESS
= 0X0E90)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Change of
DS2 Loopback
Request DS2
Channel 6
Interrupt
Enable
Change of
DS2 Loopback
Request DS2
Channel 5
Interrupt
Enable
Change of
DS2 Loopback
Request DS2
Channel 4
Interrupt
Enable
Change of
DS2 Loopback
Request DS2
Channel 3
Interrupt
Enable
Change of
DS2 Loopback
Request DS2
Channel 2
Interrupt
Enable
Change of
DS2 Loopback
Request DS2
Channel 1
Interrupt
Enable
Change of
DS2 Loopback
Request DS2
Channel 0
Interrupt
Enable
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT6 - Change of DS2 Loop-back Request - DS2 Channel 6 Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of DS2 Loop-back Request Interrupt
associated with DS2 Channel 6. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in
response to either of the following events.
•
Whenever the Receive DS3 Framer block detects and flags the DS2 Loop-back request for DS2 Channel 6.
•
Whenever the Receive DS3 Framer block clears the DS2 Loop-back request for DS2 Channel 6.
` 0 - Disables the Change of DS2 Loop-back Request Interrupt for DS2 Channel 6.
` 1 - Enables the Change of DS2 Loop-back Request Interrupt for DS2 Channel 6.
BIT 5 - Change of DS2 Loop-back Request - DS2 Channel 5 Interrupt Enable:
231
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
See description of BIT6.
BIT 4 - Change of DS2 Loop-back Request - DS2 Channel 4 Interrupt Enable
See description of BIT6.
BIT 3 - Change of DS2 Loop-back Request - DS2 Channel 3 Interrupt Enable
See description of BIT6.
BIT 2 - Change of DS2 Loop-back Request - DS2 Channel 2 Interrupt Enable
See description of BIT6.
BIT 1 - Change of DS2 Loop-back Request - DS2 Channel 1 Interrupt Enable
See description of BIT6.
BIT 0 - Change of DS2 Loop-back Request - DS2 Channel 0 Interrupt Enable
See description of BIT6.
TABLE 336: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT STATUS REGISTER (ADDRESS
= 0X0E91)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Change of
DS2 Loopback
Request DS2
Channel 6
Interrupt
Status
Change of
DS2 Loopback
Request DS2
Channel 5
Interrupt
Status
Change of
DS2 Loopback
Request DS2
Channel 4
Interrupt
Status
Change of
DS2 Loopback
Request DS2
Channel 3
Interrupt
Status
Change of
DS2 Loopback
Request DS2
Channel 2
Interrupt
Status
Change of
DS2 Loopback
Request DS2
Channel 1
Interrupt
Status
Change of
DS2 Loopback
Request DS2
Channel 0
Interrupt
Status
R/O
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT6 - Change of DS2 Loop-back Request - DS2 Channel 6 Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Change of DS2 Loop-back Request Status interrupt for
DS2 Channel 6 has occurred since the last read of this register. The XRT86SH328 will generate this interrupt in
response to either of the following conditions.
•
Whenever the Receive DS3 Framer block detects and flags the DS2 Loop-back request, for DS2 Channel 6.
•
Whenever the Receive DS3 Framer block clears the DS2 Loop-back request for DS2 Channel 6.
` 0 - Indicates that the Change of DS2 Loop-back Request Status Interrupt has NOT occurred since the last read of
this register
` 1 - Indicates that the Change of DS2 Loop-back Request Status Interrupt has occurred since the last read of this
register.
BIT 5 - Change of DS2 Loop-back Request - DS2 Channel 5 Interrupt Status
See description of BIT6.
BIT 4 - Change of DS2 Loop-back Request - DS2 Channel 4 Interrupt Status
See description of BIT6.
BIT 3 - Change of DS2 Loop-back Request - DS2 Channel 3 Interrupt Status
See description of BIT6.
BIT 2 - Change of DS2 Loop-back Request - DS2 Channel 2 Interrupt Status
See description of BIT6.
BIT 1 - Change of DS2 Loop-back Request - DS2 Channel 1 Interrupt Status
See description of BIT6.
232
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT 0 - Change of DS2 Loop-back Request - DS2 Channel 0 Interrupt Status
See description of BIT6.
TABLE 337: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST STATUS REGISTER (ADDRESS = 0X0E92)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
Receive DS2
Loop-back
Request ON
- DS2
Channel 6
Receive DS2
Loop-back
Request ON
- DS2
Channel 5
Receive DS2
Loop-back
Request ON
- DS2
Channel 4
Receive DS2
Loop-back
Request ON
- DS2
Channel 3
Receive DS2
Loop-back
Request ON
- DS2
Channel 2
Receive DS2
Loop-back
Request ON
- DS2
Channel 1
Receive DS2
Loop-back
Request ON
- DS2
Channel 0
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT6 - Receive DS2 Loop-back Request ON - DS2 Channel 6:
This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block has detected a DS2 Loop-back
Request (associated with DS2 Channel # 6) within the incoming DS3 data-stream. The Receive DS3 Framer block will
detect and flag a DS2 Loop-back Request if it detects the DS2 Loop-back Codes (pertaining to a given DS2 channel)
for 5 consecutive DS3 frames.
` 0 - Indicates that the Receive DS3 Framer block is NOT currently flagging a DS2 Loop-back Request associated with
DS2 Channel 6.
` 1 - Indicates that the Receive DS2 Framer block is currently flagging a DS2 Loop-back Request associated with DS2
Channel 6.
BIT 5 - Receive DS2 Loop-back Request ON - DS2 Channel 5
See description of BIT6.
BIT 4 - Receive DS2 Loop-back Request ON - DS2 Channel 4
See description of BIT6.
BIT 3 - Receive DS2 Loop-back Request ON - DS2 Channel 3
See description of BIT6.
BIT 2 - Receive DS2 Loop-back Request ON - DS2 Channel 2
See description of BIT6.
BIT 1 - Receive DS2 Loop-back Request ON - DS2 Channel 1
See description of BIT6.
BIT 0 - Receive DS2 Loop-back Request ON - DS2 Channel 0
See description of BIT6.
233
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 338: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 1 (ADDRESS =
0X0E93)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 3
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 2
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 1
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 0
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 3
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 2
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 1
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 0
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Change of M12 Loop-back Request Condition - DS1 Channel 3 Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the M12 De-MUX block (associated with DS2 Channel 0) has
generated the Change of M12 Loop-back Request Condition Interrupt, for DS1 Channel 3, since the last read of this
register. The M12 De-MUX block will generate this particular interrupt in response to either of the following events.
•
? Whenever it detects the M12 Loop-back Request indicator for DS1 Channel 3 (within the incoming DS2
signal)
•
Whenever it ceases to detect the M12 Loop-back Request indicator for DS1 Channel 3 (within the incoming
DS2 signal).
` 0 - Indicates that the Change of M12 Loop-back Request Condition Interrupt, for DS1 Channel 3, has NOT occurred
since the last read of this register.
` 1 - Indicates that the Change of M12 Loop-back Request Condition Interrupt, for DS1 Channel 3, has occurred since
the last read of this register.
BIT6 - Change of M12 Loop-back Request Condition - DS1 Channel 2 Interrupt Status
See description of BIT7.
BIT 5 - Change of M12 Loop-back Request Condition - DS1 Channel 1 Interrupt Status
See description of BIT7.
BIT 4 - Change of M12 Loop-back Request Condition - DS1 Channel 0 Interrupt Status
See description of BIT7.
BIT 3 - Change of M12 Loop-back Request Condition - DS1 Channel 3 Interrupt Enable
This READ/WRITE bit-field is used to either enable or disable the Change of M12 Loop-back Request
Condition Interrupt for DS1 Channel 3. If this interrupt is enabled, then the XRT86SH328 will generate an
interrupt in response to either of the following conditions.
•
Whenever the M12 De-MUX Block (associated with DS2 Channel 0) detects the M12 Loop-back Request
indicator for DS1 Channel 3 (within the incoming DS2 signal).
•
Whenever the M12 De-MUX Block ceases to detect the M12 Loop-back Request indicator for DS1 Channel 3
(within the incoming DS2 signal).
` 0 - Disables the Change of M12 Loop-back Request Condition Interrupt for DS1 Channel 3.
` 1 - Enables the Change of M12 Loop-back Request Condition Interrupt for DS1 Channel 3.
BIT 2 - Change of M12 Loop-back Request Condition - DS1 Channel 2 Interrupt Enable
See description of BIT 3.
BIT 1 - Change of M12 Loop-back Request Condition - DS1 Channel 1 Interrupt Enable
See description of BIT 3.
234
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT 0 - Change of M12 Loop-back Request Condition - DS1 Channel 0 Interrupt Enable
See description of BIT 3.
TABLE 339: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 1 (ADDRESS = 0X0E94)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
M12 LoopBack
Request
Status - DS1
Channel 3
M12 LoopBack
Request
Status - DS1
Channel 2
M12 LoopBack
Request
Status - DS1
Channel 1
M12 LoopBack
Request
Status - DS1
Channel 0
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT7 - 4 - Reserved:
BIT 3 - M12 Loop-Back Request Status - DS1 Channel 3:
This READ/WRITE bit-field indicates whether or not the M12 De-MUX Block (associated with DS2 Channel 0) is
currently detecting the M12 Loop-Back Request for DS1 Channel 3, within the incoming DS2 data-stream.
` 0 - Indicates that the M12 De-MUX Block (associated with DS2 Channel 0) is NOT currently detecting the M12 LoopBack Request for DS1 Channel 3, within the incoming DS2 data-stream.
` 1 - Indicates that the M12 De-MUX Block (associated with DS2 Channel 0) is currently detecting the M12 Loop-Back
Request for DS1 Channel 3, within the incoming DS2 data-stream.
BIT 2 - M12 Loop-Back Request Status - DS1 Channel 2:
See description of BIT 3.
BIT 1 - M12 Loop-Back Request Status - DS1 Channel 1:
See description of BIT 3.
BIT 0 - M12 Loop-Back Request Status - DS1 Channel 0:
See description of BIT 3.
TABLE 340: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 2 (ADDRESS =
0X0E95)
BIT7
BIT6
BIT 5
BIT 4
Change of
Change of
Change of
Change of
M12 LoopM12 LoopM12 LoopM12 Loopback
back
back
back
Request
Request
Request
Request
Condition Condition Condition Condition DS1
DS1
DS1
DS1
Channel 7
Channel 6
Channel 5
Channel 4
Interrupt Sta- Interrupt Sta- Interrupt Sta- Interrupt Status
tus
tus
tus
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 7
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 6
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 5
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 4
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
See Table 338 above for bit descriptions, substituting Channel [7:4] for Channel [3:0].
235
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 341: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 2 (ADDRESS = 0X0E96)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
M12 LoopBack
Request
Status - DS1
Channel 7
M12 LoopBack
Request
Status - DS1
Channel 6
M12 LoopBack
Request
Status - DS1
Channel 5
M12 LoopBack
Request
Status - DS1
Channel 4
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [7:4] for Channel [3:0].
TABLE 342: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 3 (ADDRESS =
0X0E97)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 11
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 10
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 9
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 8
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 11
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 10
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 9
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 8
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
See Table 338 above for bit descriptions, substituting Channel [11:8] for Channel [3:0].
TABLE 343: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 3 (ADDRESS = 0X0E98)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
M12 LoopBack
Request
Status - DS1
Channel 11
M12 LoopBack
Request
Status - DS1
Channel 10
M12 LoopBack
Request
Status - DS1
Channel 9
M12 LoopBack
Request
Status - DS1
Channel 8
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [11:8] for Channel [3:0].
236
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 344: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 4 (ADDRESS =
0X0E99)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 15
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 14
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 13
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 12
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 15
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 14
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 13
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 12
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
See Table 338 above for bit descriptions, substituting Channel [15:12] for Channel [3:0].
TABLE 345: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 4 (ADDRESS = 0X0E9A)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Reserved
BIT 2
BIT 1
BIT 0
M12 LoopM12 LoopM12 LoopM12 LoopBack
Back
Back
Back
Request Sta- Request Sta- Request Sta- Request Status - DS1
tus - DS1
tus - DS1
tus - DS1
Channel 15
Channel 14
Channel 13
Channel 12
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [15:12] for Channel [3:0].
TABLE 346: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 5 (ADDRESS =
0X0E9B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 19
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 18
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 17
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 16
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 19
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 18
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 17
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 16
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
See Table 338 above for bit descriptions, substituting Channel [19:16] for Channel [3:0].
237
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 347: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 5 (ADDRESS = 0X0E9C)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
M12 LoopBack
Request
Status - DS1
Channel 19
M12 LoopBack
Request
Status - DS1
Channel 18
M12 LoopBack
Request
Status - DS1
Channel 17
M12 LoopBack
Request
Status - DS1
Channel 16
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - Bit - See Table 339 above, for bit descriptions, substituting Channel [19:16] for Channel [3:0].
TABLE 348: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 6 (ADDRESS =
0X0E9D)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 23
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 22
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 21
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 20
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 23
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 22
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 21
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 20
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
See Table 338 above for bit descriptions, substituting Channel [23:20] for Channel [3:0].
TABLE 349: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 6 (ADDRESS = 0X0E9E)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
M12 LoopM12 LoopM12 LoopM12 LoopBack
Back
Back
Back
Request Sta- Request Sta- Request Sta- Request Status - DS1
tus - DS1
tus - DS1
tus - DS1
Channel 23
Channel 22
Channel 21
Channel 20
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [23:20] for Channel [3:0].
238
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 350: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 7 (ADDRESS =
0X0E9F)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Change of
M12 Loopback
Request
Condition DS1
Channel 27
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 26
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 25
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 24
Interrupt
Status
Change of
M12 Loopback
Request
Condition DS1
Channel 27
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 26
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 25
Interrupt
Enable
Change of
M12 Loopback
Request
Condition DS1
Channel 24
Interrupt
Enable
RUR
RUR
RUR
RUR
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
See Table 338 above for bit descriptions, substituting Channel [27:24] for Channel [3:0].
TABLE 351: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 7 (ADDRESS = 0X0EA0)
BIT7
BIT6
BIT 5
BIT 4
Reserved
BIT 3
BIT 2
BIT 1
BIT 0
M12 LoopM12 LoopM12 LoopM12 LoopBack
Back
Back
Back
Request Sta- Request Sta- Request Sta- Request Status - DS1
tus - DS1
tus - DS1
tus - DS1
Channel 27
Channel 26
Channel 25
Channel 24
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [27:24] for Channel [3:0].
TABLE 352: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA1)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect
Condition
Interrupt
Enable
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect
Condition
Interrupt
Enable
Change of
State of
Reserved Bit
(G.747)
Interrupt
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Unused:
BIT 5 - DS2 COFA (Change of Framing Alignment) Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the DS2 Change of Framing Alignment interrupt for DS2
Channel # 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt anytime it has
detected a change in DS2 framing alignment within the incoming DS2 data-stream.
` 0 - Disables the DS2 COFA Interrupt for DS2 Channel 1.
` 1 - Enables the DS2 COFA Interrupt for DS2 Channel 1.
239
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT 4 - Change of DS2 LOF Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of DS2 LOF Defect Condition Interrupt for
DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response to
either of the following conditions.
•
Whenever the M12 De-MUX block declares the DS2 LOF Defect condition, or
•
Whenever the M12 De-MUX block clears the DS2 LOF Defect condition.
` 0 - Disables the Change of DS2 LOF Defect Condition Interrupt for DS2 Channel 1.
` 1 - Enables the Change of DS2 LOF Defect Condition Interrupt for DS2 Channel 1.
BIT 3 - Change of DS2 FERF/RDI Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of DS2 FERF/RDI Defect Condition Interrupt
for DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response
to either of the following conditions.
•
Whenever the M12 De-MUX block declares the DS2 FERF/RDI Defect condition, or
•
Whenever the M12 De-MUX block clears the DS2 FERF/RDI Defect condition.
` 0 - Disables the Change of DS2 FERF/RDI Defect Condition Interrupt for DS2 Channel 1.
` 1 - Enables the Change of DS2 FERF/RDI Defect Condition Interrupt for DS2 Channel 1.
BIT 2 - Change of DS2 RED Alarm Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of DS2 RED Alarm Defect Condition Interrupt
for DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response
to either of the following conditions.
•
Whenever the M12 De-MUX block declares the DS2 RED Alarm Defect condition, or
•
Whenever the M12 De-MUX block clears the DS2 RED Alarm Defect condition.
` 0 - Disables the Change of DS2 RED Alarm Defect Condition Interrupt for DS2 Channel 1.
` 1 - Enables the Change of DS2 RED Alarm Defect Condition Interrupt for DS2 Channel 1.
BIT 1 - Change of DS2 AIS Defect Condition Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of DS2 AIS Defect Condition Interrupt for
DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response to
either of the following conditions.
•
Whenever the M12 De-MUX block declares the DS2 AIS Defect condition, or
•
Whenever the M12 De-MUX block clears the DS2 AIS Defect condition.
` 0 - Disables the Change of DS2 AIS Defect Condition Interrupt for DS2 Channel 1.
` 1 - Enables the Change of DS2 AIS Defect Condition Interrupt for DS2 Channel 1.
BIT 0 - Change of State of Reserved Bit (G.747) Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of State of the G.747 Reserved Bit Interrupt.
If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt anytime it detects a change of
state in the Reserved Bit within the G.747 Data Stream associated with G.747 Channel # 1.
` 0 - Disables the Change of State of the G.747 Reserved Bit Interrupt for M12 De-MUX Block Channel 1.
` 1 - Enables the Change of State of the G.747 Reserved Bit Interrupt for M12 De-MUX Block Channel 1.
NOTE: This bit-field is only active if M12 De-MUX Block # 1 has been configured to operate in the G.747 Mode.
240
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 353: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA2)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Status
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Status
Change of
DS2 AIS
Defect Condition
Interrupt
Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:6] - Unused:
BIT 5 - DS2 COFA Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the DS2 COFA Interrupt (associated with M12 De-MUX # 1)
has occurred since the last read of this register.
` 0 - Indicates that the DS2 COFA Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read
of this register.
` 1 - Indicates that the DS2 COFA Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this
register.
BIT 4 - Change of DS2 LOF Defect Condition Interrupt Status:
This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 LOF Defect Condition interrupt has
occurred (within M12 De-MUX # 1) since the last read of this register.
` 0 - Indicates that the Change of DS2 LOF Defect Condition Interrupt (associated with M12 De-MUX # 1) has NOT
occurred since the last read of this register.
` 1 - Indicates that the Change of DS2 LOF Defect Condition Interrupt (associated with M12 De-MUX # 1) has occurred
since the last read of this register.
BIT 3 - Change of DS2 FERF/RDI Defect Condition Interrupt Status:
This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 FERF/RDI Defect Condition interrupt has
occurred (within M12 De-MUX # 1) since the last read of this register.
` 0 - Indicates that the Change of DS2 FERF/RDI Defect Condition Interrupt (associated with M12 De-MUX # 1) has
NOT occurred since the last read of this register.
` 1 - Indicates that the Change of DS2 FERF/RDI Defect Condition Interrupt (associated with M12 De-MUX # 1) has
occurred since the last read of this register.
BIT 2 - Change of DS2 RED Alarm Defect Condition Interrupt Status:
This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 RED Alarm Defect Condition interrupt
has occurred (within M12 De-MUX # 1) since the last read of this register.
` 0 - Indicates that the Change of DS2 RED Alarm Defect Condition Interrupt (associated with M12 De-MUX # 1) has
NOT occurred since the last read of this register.
` 1 - Indicates that the Change of DS2 RED Alarm Defect Condition Interrupt (associated with M12 De-MUX # 1) has
occurred since the last read of this register.
BIT 1 - Change of DS2 AIS Defect Condition Interrupt Status:
This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 AIS Defect Condition interrupt has
occurred (within M12 De-MUX # 1) since the last read of this register.
` 0 - Indicates that the Change of DS2 AIS Defect Condition Interrupt (associated with M12 De-MUX # 1) has NOT
occurred since the last read of this register.
` 1 - Indicates that the Change of DS2 AIS Defect Condition Interrupt (associated with M12 De-MUX # 1) has occurred
since the last read of this register.
BIT 0 - Change of State of Reserved Bit (G.747) Interrupt Status:
241
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This RESET-upon-READ bit-field indicates whether or not the Change of State of the G.747 Reserved Bit Interrupt has
occurred (within M12 De-MUX # 1) since the last read of this register.
` 0 - Indicates that the Change of State of the G.747 Reserved Bit Interrupt (associated with M12 De-MUX # 1) has
NOT occurred since the last read of this register.
` 1 - Indicates that the Change of State of the G.747 Reserved Bit Interrupt (associated with M12 De-MUX # 1) has
occurred since the last read of this register.
NOTE: This bit-field is only active if M12 De-MUX Block # 1 has been configured to operate in the G.747 Mode.
TABLE 354: DS3 FRAMER BLOCK - DS2 # 1 FRAMER STATUS REGISTER (ADDRESS = 0X0EA3)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:5] - Unused:
BIT 4 - DS2 LOF Defect Declared:
This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 LOF defect
condition.
` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 LOF defect condition.
` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 LOF defect condition.
BIT 3 - DS2 FERF/RDI Defect Declared:
This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 FERF/RDI
defect condition.
` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 FERF/RDI defect condition.
` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 FERF/RDI defect condition.
BIT 2 - DS2 RED Alarm Defect Declared:
This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 RED Alarm
defect condition.
` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 RED Alarm defect condition.
` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 RED Alarm defect condition.
BIT 1 - DS2 AIS Defect Declared:
This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 AIS defect
condition.
` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 AIS defect condition.
` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 AIS defect condition.
BIT 0 - Current State of Reserved Bit (G.747):
This READ-ONLY bit-field reflects the current state of the G.747 Reserve bit, as relieved by M12 De-MUX Block # 1.
242
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 355: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA4)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect
Condition
Interrupt
Enable
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect
Condition
Interrupt
Enable
Change of
State of
Reserved Bit
(G.747)
Interrupt
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 2 for Channel 1 and De-MUx #2 for Demux #1.
TABLE 356: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA5)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Status
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Status
Change of
DS2 AIS
Defect
Condition
Interrupt Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 353 above, substituting De-Mux #2 for De-Mux #1.
TABLE 357: DS3 FRAMER BLOCK - DS2 # 2 FRAMER STATUS REGISTER (ADDRESS = 0X0EA6)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #2 for De-Mux #1.
243
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 358: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA7)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect Condition Interrupt Enable
Change of
DS2
FERF/RDI
Defect Condition Interrupt Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect Condition Interrupt Enable
Change of
State of
Reserved Bit
(G.747) Interrupt Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 3 for Channel 1 and De-MUx #3 for Demux #1.
TABLE 359: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA8)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Status
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Status
Change of
DS2 AIS
Defect
Condition
Interrupt Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 353 above, substituting De-Mux #3 for De-Mux #1.
TABLE 360: DS3 FRAMER BLOCK - DS2 # 3 FRAMER STATUS REGISTER (ADDRESS = 0X0EA9)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #3 for De-Mux #1.
244
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 361: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAA)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect
Condition
Interrupt
Enable
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect
Condition
Interrupt
Enable
Change of
State of
Reserved Bit
(G.747)
Interrupt
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 4 for Channel 1 and De-MUx #4 for Demux #1.
TABLE 362: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAB)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Status
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Status
Change of
DS2 AIS
Defect
Condition
Interrupt
Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 353 above substituting De-Mux #4 for De-Mux #1.
TABLE 363: DS3 FRAMER BLOCK - DS2 # 4 FRAMER STATUS REGISTER (ADDRESS = 0X0EAC)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #4 for De-Mux #1.
245
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 364: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAD)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect
Condition
Interrupt
Enable
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect
Condition
Interrupt
Enable
Change of
State of
Reserved Bit
(G.747)
Interrupt
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 5 for Channel 1 and De-MUx #5 for Demux #1.
TABLE 365: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAE)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Status
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Status
Change of
DS2 AIS
Defect Condition
Interrupt
Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 353 above substituting De-Mux #5 for De-Mux #1.
TABLE 366: DS3 FRAMER BLOCK - DS2 # 5 FRAMER STATUS REGISTER (ADDRESS = 0X0EAF)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #5 for De-Mux #1.
246
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 367: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB0)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect
Condition
Interrupt
Enable
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect
Condition
Interrupt
Enable
Change of
State of
Reserved Bit
(G.747)
Interrupt
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 2 for Channel 6 and De-MUx #6 for Demux #1.
TABLE 368: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB1)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Status
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Status
Change of
DS2 AIS
Defect Condition
Interrupt
Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 353 above substituting De-Mux #6 for De-Mux #1.
TABLE 369: DS3 FRAMER BLOCK - DS2 # 6 FRAMER STATUS REGISTER (ADDRESS = 0X0EB2)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #6 for De-Mux #1.
247
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 370: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB3)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 COFA
Interrupt
Enable
Change of
DS2 LOF
Defect
Condition
Interrupt
Enable
Change of
DS2
FERF/RDI
Defect
Condition
Interrupt
Enable
Change of
DS2 RED
Alarm Defect
Condition
Interrupt
Enable
Change of
DS2 AIS
Defect
Condition
Interrupt
Enable
Change of
State of
Reserved Bit
(G.747)
Interrupt
Enable
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 7 for Channel 1 and De-MUx #7 for Demux #1.
TABLE 371: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB4)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
DS2 COFA
Interrupt
Status
Change of
DS2 LOF
Defect
Condition
Interrupt
Status
BIT 3
BIT 2
Change of
Change of
DS2
DS2 RED
FERF/RDI
Alarm Defect
Defect
Condition
Interrupt
Condition
Status
Interrupt Status
BIT 1
BIT 0
Change of
DS2 AIS
Defect
Condition
Interrupt
Status
Change of
State of
Reserved Bit
(G.747)
Interrupt
Status
R/O
R/O
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 353 above, substituting De-Mux #7 for De-Mux #1.
TABLE 372: DS3 FRAMER BLOCK - DS2 # 7 FRAMER STATUS REGISTER (ADDRESS = 0X0EB5)
BIT 7
BIT 6
BIT 5
Unused
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
DS2 LOF
Defect
Declared
DS2
FERF/RDI
Defect
Declared
DS2 RED
Alarm Defect
Declared
DS2 AIS
Defect
Declared
Current State
of Reserved
Bit (G.747)
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #7 for De-Mux #1.
248
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 373: DS3 FRAMER BLOCK - M13 DE-MUX REGISTER (ADDRESS = 0X0EB8)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Auto DS1/E1
AIS upon
DS2 OOF
Defect
Unused
Auto DS1/E1
AIS upon
DS2 AIS
Defect
Unused
R/O
R/O
R/O
R/O
R/W
R/O
R/W
R/O
0
0
0
0
0
0
0
0
BIT [7:4] - Unused:
BIT 3 - Auto DS1/E1 AIS upon DS2 LOF Defect:
This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (associated
with a given M12 De-MUX block) to automatically transmit the DS1/E1 AIS indicator via each of its three or four downstream DS1/E1 signals, anytime (and for the duration that) the corresponding M12 De-MUX block declares the DS2
LOF defect condition.
` 0 - Does not configure each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit
DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream
DS1/E1 signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 LOF defect condition.
` 1 - Configures each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit DS1/E1
Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream DS1/E1
signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 LOF defect condition.
NOTE: This bit-setting applies to each of the seven (7) M12 De-MUX blocks within the XRT86SH328.
BIT 2 - Unused:
BIT 1 - Auto DS1/E1 AIS upon DS2 AIS Defect:
This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (associated
with a given M12 De-MUX block) to automatically transmit the DS1/E1 AIS indicator via each of its three or four downstream DS1/E1 signals, anytime (and for the duration that) the corresponding M12 De-MUX block declares the DS2 AIS
defect condition.
` 0 - Does not configure each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit
DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream
DS1/E1 signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 AIS defect condition.
` 1 - Configures each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit DS1/E1
Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream DS1/E1
signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 AIS defect condition.
NOTE: This bit-setting applies to each of the seven (7) M12 De-MUX blocks within the XRT86SH328328.
BIT 0 - Unused:
2.12
T1/E1 LIU CHANNEL CONTROL REGISTERS
• (N ranges from 0x01 to 0x1C)
TABLE 374: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN000)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
PRBS/QRSS
PRBS_Rx_Tx
RXON
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
BIT 2
BIT 1
BIT 0
R/W
R/W
R/W
0
0
0
EQC[4:0]
BIT7 - PRBS/QRSS:
These bits are used to select between QRSS and PRBS. To send the a QRSS or PRBS pattern, the TxTEST[2:0] bits
in register 0xN002h must be programmed.
249
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 0 = QRSS
` 1 = PRBS
BIT6 - PRBS/QRSS Direction Select Rx/Tx:
This bit is used to select which direction is used to send the PRBS/QRSS pattern if enabled within the TxTEST[2:0] bits
in register 0xN002h.
` 0 = Line Interface (Ttip/Tring)
` 1 = System Side Interface (Clock/Data)
BIT 5 - RXON Receiver Enable:
This bit is used enable the receiver line interface. By default, the receivers are turned off to support redundancy.
` 0 = Disabled.
` 1 = Enabled.
BIT [4:0] - Equalizer Control and Line Build Out:
These bits are used to select the equalizer control and line build out.
Selection Chart for Equalizer Control and Line Build-Out
EQC[4:0]
T1/E1 MODE RECEIVE
SENSITIVITY
TRANSMIT LBO
CABLE
CODING
01000
T1 Short Haul
0 - 133 Ft (0.6dB)
100W TP
B8ZS
01001
T1 Short Haul
0 - 133 Ft (0.6dB)
100W TP
B8ZS
01010
T1 Short Haul
0 - 133 Ft (0.6dB)
100W TP
B8ZS
01011
T1 Short Haul
0 - 133 Ft (0.6dB)
100W TP
B8ZS
01100
T1 Short Haul
0 - 133 Ft (0.6dB)
100W TP
B8ZS
01101
T1 Short Haul
Arbitrary Pulse
100W TP
B8ZS
11100
E1 Short Haul
ITU G.703
75W Coax
HDB3
11101
E1 Short Haul
ITU G.703
120W TP
HDB3
TABLE 375: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN001)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
RxTSEL
TxTSEL
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
TERSEL[1:0]
BIT 2
BIT 1
BIT 0
JABW
FIFOS
R/W
R/W
R/W
0
0
0
JASEL[1:0]
BIT7 - RxTSEL:
This bit is used for the receive line interface to select between Internal (automatic line impedance) and External (high
impedance) modes.
` 0 = External Impedance
` 1 = Internal Impedance
BIT6 - TxTSEL:
This bit is used for the transmit line interface to select between Internal (automatic line impedance) and External (high
impedance) modes.
` 0 = External Impedance
` 1 = Internal Impedance
BIT [5:4] - TERSEL[1:0]:
250
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
These bits are used to select the line impedance for internal termination control.
` 00 = 100W
` 01 = 110W
` 10 = 75W
` 11 = 120W
BIT [3:2] - JASEL[1:0]:
These bits are used to select which path the Jitter Attenuator is placed.
` 00 = Disabled.
` 01 = Transmit Line Interface Path
` 10 = Receive Line Interface Path
` 11 = Receive Line Interface Path
` BIT 1 - Jitter Attenuator Band Width:
The jitter band width is a global setting that is applied in both transmit and receive directions.
` 0 = 10 Hz
` 1 = 1.5 Hz
BIT 0 - First In First Out Bit Depth:
This bit is used for the transmit line interface to select between Internal (automatic line impedance) and External (high
impedance) modes.
` 0 = 32-Bit
` 1 = 64-Bit
TABLE 376: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN002)
BIT7
BIT6
INVQRSS
BIT 5
BIT 4
BIT 3
TxTEST[2:0]
BIT 2
TXON
BIT 1
BIT 0
LOOP[2:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Invert QRSS:
INVQRSS is used to invert the transmit QRSS pattern set by the TxTEST[2:0] bits. By default, INVQRSS is disabled
and the QRSS will be transmitted with normal polarity.
` 0 = External Impedance
` 1 = Internal Impedance
BIT [6:4] - Tx Test Pattern [2:0]:
These bits are used to select a Test Pattern to be sent to the transmit line interface. If bit 6 in register 0xN000h is set
High, then the Test Pattern will be sent out on the receive DS-1/E1 system side.
` 0XX = No Test Pattern
` 100 = Tx QRSS
` 101 = Tx TAOS
` 110 = Reserved
` 111 = Reserved
BIT 3 - TXON Transmitter Enable:
This bit is used enable the transmitter line interface. By default, the transmitters are turned off to support redundancy.
` 0 = Disabled.
` 1 = Enabled.
BIT [2:0] - Loop Back Mode Select [2:0]:
251
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
These bits are used to select a loop back mode for diagnostic testing. These bits only represent the loop back modes
supported in the LIU section of Voyager. For other loop back mode options, see the register map in other modes of
operation.
` 0XX = No Loop Back
` 100 = Dual Loop Back
` 101 = Analog Loop Back
` 110 = Remote Loop Back
` 111 = Digital Loop Back
TABLE 377: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN003)
BIT7
BIT6
RxRES[1:0]
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CODES
Reserved
E1ARBIT
INSBPV
INSBER
Reserved
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Receiver Fixed External Termination:
RxRES[1:0] are used to select the value for a high precision external resistor to improve return loss.
` 00 = None
` 01 = 240W
` 10 = 210W
` 11 = 150W
BIT 5 - CODES Encoding / Decoding Select:
This bit is used to select the type of encoding/decoding the transmitter and receiver will generate/process.
` 0 = HDB3 (E1), B8ZS (T1)
` 1 = AMI Coding
BIT 4 - Reserved:
BIT 3 - E1Arbitrary Pulse Select:
This bit is used to enable the Arbitrary Pulse Generator for shaping the transmit pulse when E1 mode is selected.
` 0 = Disabled (Normal E1 Pulse Shape ITU G.703)
` 1 = Arbitrary Pulse Enabled
BIT 2 - Insert Bipolar Violation:
When this bit transitions from Low to High, a bipolar violation will be inserted in the transmitted data from TPOS,
QRSS/PRBS pattern. The state of this bit will be sampled on the rising edge of TCLK. To ensure proper operation, it
is recommended to write a 0 to this bit before writing a 1.
` 0 to 1 Transition = Insert one bipolar violation
BIT 1 - Insert Bit Error:
When this bit transitions from Low to High, a bit error will be inserted in the transmitted QRSS/PRBS pattern. The state
of this bit will be sampled on the rising edge of TCLK. To ensure proper operation, it is recommended to write a 0 to
this bit before writing a 1.
` 0 to 1 Transition = Insert one bit error
BIT 0 - Reserved:
252
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 378: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN004)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DMOIE
FLSIE
LCVIE
Reserved
AISDIE
RLOSIE
QRPDIE
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT6 - Digital Monitor Output Interrupt Enable:
` 0 = Masks the DMO function
` 1 = Enables interrupt generation for DMO
BIT 5 - FIFO Limit Status Interrupt Enable:
` 0 = Masks the FLS function
` 1 = Enables interrupt generation for FLS
BIT 4 - Line Code Violation Interrupt Enable:
` 0 = Masks the LCV function
` 1 = Enables interrupt generation for LCV
BIT 3 - Reserved:
BIT 2 - Alarm Indication Signal Interrupt Enable:
` 0 = Masks the AIS function
` 1 = Enables interrupt generation for AIS
BIT 1 - Receive Loss of Signal Interrupt Enable:
` 0 = Masks the RLOS function
` 1 = Enables interrupt generation for RLOS
BIT 0 - Quasi Random Pattern Detection Interrupt Enable:
` 0 = Masks the QRPD function
` 1 = Enables interrupt generation for QRPD
TABLE 379: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN005)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DMO
FLS
LCV
Reserved
AISD
RLOS
QRPD
RO
RO
RO
RO
RO
RO
RO
RO
0
0
0
0
0
0
0
0
BIT6 - Digital Monitor Output:
This bit indicates the DMO activity. An interrupt will not occur unless the DMOIE is set High in register 0xN004h and
the global interrupt enable has been set.
` 0 = No Alarm
` 1 = Transmit output driver has failures
BIT 5 - FIFO Limit Status:
This bit indicates whether the RD/WR pointers are within 3-Bits. An interrupt will not occur unless the FLSIE is set High
in register 0xN004h and the global interrupt enable has been set.
` 0 = No Alarm
` 1 = RD/WR FIFO pointers are within ±3-Bits
BIT 4 - Line Code Violation:
253
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
This bit serves a dual purpose. By default, this bit monitors the line code violation activity. However, if bit 7 in register
0x0101h is set High, this bit monitors the overflow status of the internal LCV counter. An interrupt will not occur unless
the LCV/OFIE is set High in register 0xN004h and the global interrupt enable has been set.
` 0 = No Alarm
` 1 = A line code violation, bipolar violation, or excessive zeros has occurred
BIT 3 - Reserved:
BIT 2 - Alarm Indication Signal:
This bit indicates the AIS activity. An interrupt will not occur unless the AISIE is set High in register 0xN004h and the
global interrupt enable has been set.
` 0 = No Alarm
` 1 = An all ones signal is detected
BIT 1 - Receive Loss of Signal:
This bit indicates the RLOS activity. An interrupt will not occur unless the RLOSIE is set High in register 0xN004h and
the global interrupt enable has been set.
` 0 = No Alarm
` 1 = An RLOS condition is present
BIT 0 - Quasi Random Pattern Detection:
This bit indicates that a QRPD has been detected. An interrupt will not occur unless the QRPDIE is set High in register
0xN004h and the global interrupt enable has been set.
` 0 = No Alarm
` 1 = A QRP is detected
TABLE 380: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN006)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
DMOIS
FLSIS
LCVIS
Reserved
AISDIS
RLOSIS
QRPDIS
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
NOTE: These register bits are Reset Upon Read. They will be set High anytime a change in status occurs. Once these bits
are read back, they will automatically be set Low.
BIT7 - Reserved:
BIT6 - Digital Monitor Output Interrupt Enable:
` 0 = No change
` 1 = Change in status occurred
BIT 5 - FIFO Limit Status Interrupt Enable:
` 0 = No change
` 1 = Change in status occurred
BIT 4 - Line Code Violation Interrupt Enable:
` 0 = No change
` 1 = Change in status occurred
BIT 3 - Reserved:
BIT 2 - Alarm Indication Signal Interrupt Enable:
` 0 = No change
` 1 = Change in status occurred
BIT 1 - Receive Loss of Signal Interrupt Enable:
` 0 = No change
254
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 1 = Change in status occurred
BIT 0 - Quasi Random Pattern Detection Interrupt Enable:
` 0 = No change
` 1 = Change in status occurred
TABLE 381: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN007)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
ENROM
Reserved
Reserved
RSTALL
UPDATEALL
HI/LO
UPDATE
RST
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Enable ROM for LCV Counter:
This bit is used to enable data from an internal LCV counter to be read back.
` 0 = Disabled.
` 1 = Enabled.
BIT [6:5] - Reserved:
BIT 4 - Reset All Internal LCV Counters:
This bit is used to reset all 28 Internal LCV counters to their default state 0000h. This bit must be set High for a minimum
of 1mS.
` 0 = Normal Operation
` 1 = Resets All LCV Counters
BIT 3 - Update All LCV Counters:
This bit is used to latch the contents of all 28 internal LCV counters so that the values can be read. When the HI/LO bit
is set Low, initiating this update bit places the lower 8 bits of the 16-bit word in register 0xN011h. When the HI/LO bit is
set High, initiating this update bit places the upper 8 bits of the 16-bit word in register 0xN010h.
` 0 = Normal Operation
` 1 = Updates All LCV Counters
BIT 2 - High Byte / Low Byte Select:
This bit is used to select which byte of the 16-bit LCV value will be placed in the read back registers.
` 0 = Lower Byte LCV[7:0]
` 1 = Upper Byte LCV[15:8]
BIT 1 - Update LCV Counter:
This bit is used to latch the contents of the internal LCV counter for this channel so that the value can be read. When
the HI/LO bit is set Low, initiating this update bit places the lower 8 bits of the 16-bit word in register 0xN011h. When
the HI/LO bit is set High, initiating this update bit places the upper 8 bits of the 16-bit word in register 0xN010h.
` 0 = Normal Operation
` 1 = Update LCV Counter
BIT 0 - Reset Internal LCV Counter:
This bit is used to reset the Internal LCV for this channel to its default state 0000h. This bit must be set High for a
minimum of 1mS.
` 0 = Normal Operation
` 1 = Reset LCV Counter
255
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 382: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN008)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S1
B5S1
B4S1
B3S1
B2S1
B1S1
B0S1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 1:
The transmit output pulse is divided into 8 individual segments. This register is used to program the first segment which
corresponds to the overshoot of the pulse amplitude. There are four segments for the top portion of the pulse and four
segments for the bottom portion of the pulse. Segment number 5 corresponds to the undershoot of the pulse. The MSB
of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
TABLE 383: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN009)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S2
B5S2
B4S2
B3S2
B2S2
B1S2
B0S2
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 2:
The transmit output pulse is divided into 8 individual segments. This register is used to program the second segment
of the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
TABLE 384: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00A)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S3
B5S3
B4S3
B3S3
B2S3
B1S3
B0S3
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 3:
The transmit output pulse is divided into 8 individual segments. This register is used to program the Third segment of
the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
256
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 385: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00B)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S4
B5S4
B4S4
B3S4
B2S4
B1S4
B0S4
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 4:
The transmit output pulse is divided into 8 individual segments. This register is used to program the Fourth segment of
the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
TABLE 386: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S5
B5S5
B4S5
B3S5
B2S5
B1S5
B0S5
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 5:
The transmit output pulse is divided into 8 individual segments. This register is used to program the Fifth segment of
the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
TABLE 387: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00D)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S6
B5S6
B4S6
B3S6
B2S6
B1S6
B0S6
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 6:
The transmit output pulse is divided into 8 individual segments. This register is used to program the Sixth segment of
the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
257
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 388: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00E)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S7
B5S7
B4S7
B3S7
B2S7
B1S7
B0S7
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 7:
The transmit output pulse is divided into 8 individual segments. This register is used to program the Seventh segment
of the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
TABLE 389: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00F)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
B6S8
B5S8
B4S8
B3S8
B2S8
B1S8
B0S8
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved:
BIT [6:0] - Arbitrary Pulse Generation Segment 8:
The transmit output pulse is divided into 8 individual segments. This register is used to program the Eighth segment of
the pulse amplitude. The MSB of each segment is the sign bit.
• If Sign Bit (BIT6) =:
` 0 - Negative Direction
` 1 - Positive Direction
TABLE 390: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN010)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LCVHI7
LCVHI6
LCVHI5
LCVHI4
LCVHI3
LCVHI2
LCVHI1
LCVHI0
RO
RO
RO
RO
RO
RO
RO
RO
0
0
0
0
0
0
0
0
BIT [7:0] - Internal LCV Counter High Byte:
Once the internal LCV counter has been enabled and updated, these bits contain the upper byte of the 16-bit LCV
counter word.
258
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 391: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN011)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LCVLO7
LCVLO6
LCVLO5
LCVLO4
LCVLO3
LCVLO2
LCVLO1
LCVLO0
RO
RO
RO
RO
RO
RO
RO
RO
0
0
0
0
0
0
0
0
BIT [7:0] - Internal LCV Counter Low Byte:
Once the internal LCV counter has been enabled and updated, these bits contain the lower byte of the 16-bit LCV
counter word.
2.13
DS1/E1 FRAMER BLOCK REGISTERS - DS1 APPLICATIONS
The register map for the DS1/E1 Framer blocks (for DS1 Applications) is presented in the Table below.
Additionally, a detailed description of each of the DS1/E1 Framer Block register is presented below.
NOTE: The register map/description for the DS1/E1 Framer blocks (for E1 Applications) is presented in Section _.
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328 device, with both the Ingress and Egress Direction Transmit/Receive DS1/E1 Framer blocks
highlighted is presented below in Figure 17..
FIGURE 17. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT/RECEIVE DS1/E1 FRAMER BLOCKS HIGHLIGHTED
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
SOME COMMENTS ABOUT ADDRESSING DS1/E1 FRAMER BLOCK REGISTERS
259
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Throughout the XRT86SH328 Data Sheet, the user can control/monitor the function/performance of the T1/E1
Framer blocks consists of the following sets of Registers.
• Channel Control Registers
• Receive Signaling Array Registers
• LAPD Buffer 0 Data Registers
• LAPD Buffer 1 Data Registers
• Channel - Framer Performance Monitor Registers
• Channel - Framer Interrupt Register
In the XRT86SH328 Data Sheet, we indicate that the following sets of Register have the following Address
Locations.
TABLE 392: MEMORY MAP - T1/E1 FRAMER BLOCK
ADDRESS LOCATION
REGISTER SET
0xN100 - 0xN1FF
Channel X - Control Registers
0xN200 - 0xN2FF
Reserved
0xN300 - 0xN3FF
Channel X - Channel Control Registers
0xN400 - 0xN4FF
Reserved
0xN500 - 0xN5FF
Channel X - Receive Signaling Array Registers
0xN600 - 0xN6FF
Channel X - LAPD Buffer 0 Data Register
0xN700 - 0xN7FF
Channel X - LAPD Buffer 1 Data Register
0xN800 - 0xN8FF
Reserved
0xN900 - 0xN9FF
Channel X - Framer Performance Monitor Registers
0xNA00 - 0xNAFF
Reserved
0xNB00 - 0xNBFF
Channel X - Framer Interrupt Registers
NOTE: The XRT86SH328 has a total of 28 Ingress Direction Transmit/Receive DS1/E1 Framer blocks and 28 Egress
Direction Transmit/Receive DS1/E1 Framer Blocks. Hence, the XRT86SH328 device contains a total of 56
Transmit/Receive DS1/E1 Framer blocks. Therefore, in Table _-1, the value of N can range in value from 0x01 to
0x38.
OBVIOUS QUESTION: What value of N pertains to which of the 56 T1/E1 Framer blocks within the
chip?
The answer to this question depends upon whether the XRT86SH328 has been configured to operate in the
VT-Mapper (with T1/E1 Framing) or in the M13 MUX (with T1/E1 Framing) Mode. Table 393 and Table 394
present the values for N (for each T1/E1 Framer block) as a function of Channel Number and Signal Direction
for VT- Mapper (with T1/E1 Framing) and M13 MUX (with T1/E1 Framing) applications, respectively. Further,
Figure 18 (which depicts an illustration of the various T1/E1 Framer blocks within a given channel) can be
used as a point of reference when looking at Table 393 and Table 394.
260
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
REV. P1.0.6
FIGURE 18. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE WITH BOTH THE
INGRESS AND EGRESS DIRECTION T1/E1 FRAMER BLOCKS (OF A GIVEN T1/E1 CHANNEL) HIGHLIGHTED
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
TABLE 393: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - VT-MAPPER (WITH
T1/E1 FRAMING) MODE APPLICATIONS
INGRESS DIRECTION
EGRESS DIRECTION
CHANNEL NUMBER
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
1
0x1D
0x01
0x01
0x1D
2
0x1E
0x02
0x02
0x1E
3
0x1F
0x03
0x03
0x1F
4
0x20
0x04
0x04
0x20
5
0x21
0x05
0x05
0x21
6
0x22
0x06
0x06
0x22
7
0x23
0x07
0x07
0x23
8
0x24
0x08
0x08
0x24
9
0x25
0x09
0x09
0x25
261
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 393: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - VT-MAPPER (WITH
T1/E1 FRAMING) MODE APPLICATIONS
INGRESS DIRECTION
EGRESS DIRECTION
CHANNEL NUMBER
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
10
0x26
0x0A
0x0A
0x26
11
0x27
0x0B
0x0B
0x27
12
0x28
0x0C
0x0C
0x28
13
0x29
0x0D
0x0D
0x29
14
0x2A
0x0E
0x0E
0x2A
15
0x2B
0x0F
0x0F
0x2B
16
0x2C
0x10
0x10
0x2C
17
0x2D
0x11
0x11
0x2D
18
0x2E
0x12
0x12
0x2E
19
0x2F
0x13
0x13
0x2F
20
0x30
0x14
0x14
0x30
21
0x31
0x15
0x15
0x31
22
0x32
0x16
0x16
0x32
23
0x33
0x17
0x17
0x33
24
0x34
0x18
0x18
0x34
25
0x35
0x19
0x19
0x35
26
0x36
0x1A
0x1A
0x36
27
0x37
0x1B
0x1B
0x37
28
0x38
0x1C
0x1C
0x38
TABLE 394: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - M13 MUX (WITH
T1/E1 FRAMING) MODE APPLICATIONS
INGRESS DIRECTION
EGRESS DIRECTION
CHANNEL NUMBER
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
1
0x01
0x1D
0x1D
0x01
2
0x02
0x1E
0x1E
0x02
3
0x03
0x1F
0x1F
0x03
4
0x04
0x20
0x20
0x04
5
0x05
0x21
0x21
0x05
6
0x06
0x22
0x22
0x06
262
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
REV. P1.0.6
TABLE 394: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - M13 MUX (WITH
T1/E1 FRAMING) MODE APPLICATIONS
INGRESS DIRECTION
EGRESS DIRECTION
CHANNEL NUMBER
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
RECEIVE DS1/E1
FRAMER BLOCK
TRANSMIT DS1/E1
FRAMER BLOCK
7
0x07
0x23
0x23
0x07
8
0x08
0x24
0x24
0x08
9
0x09
0x25
0x25
0x09
10
0x0A
0x26
0x26
0x0A
11
0x0B
0x27
0x27
0x0B
12
0x0C
0x28
0x28
0x0C
13
0x0D
0x29
0x29
0x0D
14
0x0E
0x2A
0x2A
0x0E
15
0x0F
0x2B
0x2B
0x0F
16
0x10
0x2C
0x2C
0x10
17
0x11
0x2D
0x2D
0x11
18
0x12
0x2E
0x2E
0x12
19
0x13
0x2F
0x2F
0x13
20
0x14
0x30
0x30
0x14
21
0x15
0x31
0x31
0x15
22
0x16
0x32
0x32
0x16
23
0x17
0x33
0x33
0x17
24
0x18
0x34
0x34
0x18
25
0x19
0x35
0x35
0x19
26
0x1A
0x36
0x36
0x1A
27
0x1B
0x37
0x37
0x1B
28
0x1C
0x38
0x38
0x1C
TABLE 395: T1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
Set T1 Mode
Force all
Channels to
Sync to 8kHz
R/O
R/W
R/W
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
1
Unused
BIT7 - Reserved
263
BIT 1
BIT 0
Clock Source Select[1:0]
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT6 - Set T1 Mode:
This READ/WRITE bit-field is used to configure the Channel to operate in either the T1 or E1 Mode.
` 0 - Configures the Framer Channel to operate in the E1 Mode
` 1 - Configures the Framer Channel to operate in the T1 Mode
BIT 5 - Force all Channels to Sync to 8kHz:
This READ/WRITE bit-field is used to configure all active (either 28 or 56) Transmit DS1 Framer blocks to synchronize
their transmit output frame alignment with the 8kHz signal that is derived from the MCLK PLL.
` 0 - Does not configure each of the Transmit DS1 Framer blocks to synchronize their transmit output frame alignment
with the 8kHz signal (from the MCLK PLL).
` 1 - Configures each of the Transmit DS1 Framer blocks to synchronize their transmit output frame alignment with the
8kHz signal (from the MCLK PLL).
NOTE: This feature should only be used if the XRT86SH328 has been configured to operate in the 28-Channel DS1
Framer/LIU Combo Mode. The user MUST NOT use this feature if the XRT86SH328 has been configured to
operate in any of the Aggregation Modes.
BIT [4:2] - Reserved
BIT [1:0] - Clock Source Select[1:0]:
These two READ/WRITE bit-fields is used to specify the timing source for the Ingress and Direction Transmit DS1
Framer block, within this particular channel.
The Relationship between the Clock Source Select[1:0] bit-fields and the resulting timing source
for the Transmit DS1 Framer block, within this particular Channel
CLOCK SOURCE SELECT[1:0]
TIMING SOURCE FOR TRANSMIT DS1 FRAMER BLOCK
00
Loop-Timing Mode:The Transmit DS1 Framer block will derive its timing from the
Received or Recovered Clock signal within the corresponding Receive DS1
Framer block.NOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 28-Channel DS1 Framer/LIU Combo
Mode
01
Local-Timing Mode (TxDS1CLK_n Input)The Transmit DS1 Framer block will
either use up-stream timing or the TxDS1CLK_n input as its timing
source.NOTE: For Aggregation Applications, the user MUST configure all active
DS1 Framer blocks to operate in this timing mode.
10
Local-Timing Mode (MCLK PLL Input)The Transmit DS1 Framer block will derive
its timing from the MCLK PLL.NOTE: This timing option is only available if the
user has configured the XRT86SH328 to operate in the 28-Channel DS1
Framer/LIU Combo Mode.
11
Loop-Timing ModeThe Transmit DS1 Framer block will derive its timing from the
Received or Recovered Clock signal within the corresponding Receive DS1
Framer blockNOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 28-Channel DS1 Framer/LIU Combo
Mode.
TABLE 396: T1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Transmit
LOS Pattern
Reserved
R/W
R/O
R/W
R/W
R/O
0
1
0
0
0
BIT 2
BIT 1
BIT 0
R/O
R/O
R/O
0
0
0
Framer Loop-Back[1:0]
Reserved
264
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT7 - Transmit LOS Pattern:
This READ/WRITE bit-field configures the Transmit DS1 Framer block to generate and transmit the LOS Pattern to the
remote terminal.
` 0 - Configures the Transmit DS1 Framer Block to transmit normal DS1 traffic
` 1 - Configures the Transmit DS1 Framer Block to transmit the LOS pattern.
NOTE: The user MUST set this bit-field to 0 for Normal Operation.
BIT6 - Reserved:
BIT [5:4] - Framer Loop-back[1:0]:
These two READ/WRITE bit-fields are used to configure the Transmit/Receive DS1 Framer blocks to operate in a
variety of possible loop-back modes, as depicted in the Table below.
Relationship between the Framer Loop-back[1:0] bit-fields and the Corresponding Loop-Back
Mode within the DS1 Framer block
FRAMER LOOP-BACK[1:0]
RESULTING LOOP-BACK MODE (WITHIN FRAMER BLOCK)
00
Normal Operation (No Loop-back) Mode
01
Local Loop-back Mode
10
Remote Loop-back Mode
11
Reserved
TABLE 397: T1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Signaling
Update on
Super Frame
Boundaries
Force CRC
Errors
Set J1 Mode
One & Only
Fast Sync
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
DS1 Framing Format Select[2:0]
BIT7 - Signaling Update on Super Frame Boundaries:
This READ/WRITE bit-field is used to either enable or disable Signaling Update on Super-Frame Boundaries, in both
the Transmit and Receive Directions, as described below.
In the Receive Direction
If the user enables this feature, then signaling data will update (via the Receive Signaling Array Registers) only upon
the Super-Frame Boundaries. If the user does NOT to enable this feature, then signaling data will be updated (within
the Receive Signaling Array Registers) as soon as they are received within the incoming DS1 data-stream.
In the Transmit Direction
If the user enables this feature, then any signaling data that occur (within the Transmit Output DS1 data-stream) will be
updated upon the Super-Frame boundaries. If the user does NOT to enable this feature, then signaling data (within the
outbound DS1 data-stream) will be updated as soon as it is changed.
` 0 = Disables the Signaling Update on Super-Frame Boundaries features.
` 1 = Enables the Signaling Update on Super-Frame Boundaries features.
BIT6 - Force CRC Errors:
This READ/WRITE bit-field is used to force the Transmit DS1 Framer block to transmit CRC errors within the outbound
DS1 data-stream.
` 0 = Configures the Transmit DS1 Framer block to transmit DS1 data with correct CRC values
265
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 1 = Configures the Transmit DS1 Framer block to transmit DS1 data with erred CRC values.
NOTE: The Transmit DS1 Framer block will transmit DS1 data, with erred CRC values, for the duration that this bit-field
is set to 1.
BIT 5 - Set J1 Mode:
This READ/WRITE bit-field, along with BIT6 (Set T1 Mode) within the T1/E1 Framer Block - Clock Select Register
(Address = 0xN100) is used to configure the Channel to operate in the J1 Mode.
The Relationship between the States of the Set T1 Mode and the Set J1 Mode bit-fields and the
Corresponding Mode of Channel
SET J1 MODE
SET T1 MODE (BIT6 IN 0XN100)
OPERATING MODE OF CHANNEL
0
0
E1 Mode
0
1
T1 Mode
1
0
E1 Mode
1
1
J1 Mode
BIT 4 - One & Only:
BIT 3 - Fast Sync:
BIT [2:0] - DS1 Framing Format Select[2:0]:
These three READ/WRITE bit-fields is used to select the Framing format that the DS1 Framer Channel will operate ini.
The Relationship between the state of the DS1 Framing Format Select[2:0] bits and the
resulting Framing format of the channel
DS1 FRAMING FORMAT SELECT[2:0]
RESULTING FRAMING FORMAT
0XX
DS1, ESF - Extended Super-Frame
100
Do Not Use
101
DS1, SF - Super-Frame
11X
Do Not Use
TABLE 398: T1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Yellow Alarm
- One Second Rule
Transmit Yellow Alarm
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Yellow Alarm Format[1:0]
BIT 2
Transmit AIS Pattern
Select[1:0]
BIT 1
BIT 0
AIS Defect Declaration Criteria[1:0]
BIT7 - Yellow Alarm - One Second Rule:
This READ/WRITE bit-field is used to configure the Transmit DS1 Framer to transmit the RAI (or Yellow Alarm) indicator
per the One Second Rule (as described in the ANSI standards).
Transmission of the RAI Indicator per the One Second Rule
If the user invokes the One Second Rule, then the following will happen.
•
Whenever the Transmit DS1 Framer block generates and transmits the RAI indicator, it will do so for at least
one second (for both the ESF and the SF framing formats)
266
PRELIMINARY
REV. P1.0.6
•
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
The Transmit DS1 Framer block will insure that there is a minimum of a one-second delay between the time
that it terminates transmission of the RAI indicator, and the instant that it proceeds to transmit the RAI
indicator again.
Transmission of the RAI Indicator when the One Second Rule is NOT in-force
If the user does NOT invoke the One Second Rule, then the following will happen.
•
Whenever the Transmit DS1 Framer block generates and transmits the RAI indicator, it will do so for at least
one second (for both the ESF and the SF framing formats).
•
The Transmit DS1 Framer block will NOT insure that there is a minimum of a one-second delay between the
time that it terminates transmission of the RAI indicator, and the instant that it proceeds to transmit the RAI
indicator again.
` 0 = Does not configure the Transmit DS1 Framer block to transmit the RAI indicator per the One Second Rule.
` 1 = Configures the Transmit DS1 Framer block to transmit the RAI indicator per the One Second Rule.
BIT6 - Transmit Yellow Alarm:
BIT [5:4] - Yellow Alarm Format[1:0]:
BIT [3:2] - Transmit AIS Pattern Select[1:0]:
These two READ/WRITE bit-fields serves the following two functions.
•
To command the Transmit DS1 Framer block to transmit the AIS indicator (per Software Command), and
•
To specify the type of AIS Pattern that the Transmit DS1 Framer block will transmit, whenever it has been
commanded to transmit the AIS indicator to the remote terminal equipment.
The Relationship between Transmit AIS Pattern Select[1:0] and the resulting behavior of the
Transmit DS1 Framer block
TRANSMIT AIS PATTERN
SELECT[1:0]
TRANSMIT DS1 FRAMER BLOCK ACTION
00/10
Transmits Normal TrafficTransmit DS1 Framer block does not transmit the AIS indicator. It will (instead) transmit normal traffic
01
Unframed All Ones PatternThe Transmit DS1 Framer block will transmit an
Unframed All Ones Pattern (as an AIS pattern) for the duration that these bit-fields
are set to [0, 1].
11
Framed All Ones PatternThe Transmit DS1 Framer block will transmit a Framed All
Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [1,
0].
BIT [1:0] - AIS Defect Declaration Criteria[1:0]:
These two READ/WRITE bit-fields are used to select the type of AIS Pattern that the Receive DS1 Framer block will
look for in order to determine whether or not it should declare or clear the AIS defect condition
The Relationship between AIS Defect Declaration Criteria[1:0] and the resulting AIS Pattern that the
Receive DS1 Framer block will look for in declaring/clearing the AIS defect condition
AIS DEFECT DECLARATION
CRITERIA[1:0]
00/10
RECEIVE DS1 FRAMER BLOCK - AIS DEFECT DECLARATION CRITERIA
AIS Defect Declaration is DisabledThe Receive DS1 Framer block will NOT declare
the AIS defect condition at all.
01
Unframed and Framed All Ones Pattern:The Receive DS1 Framer block will declare
the AIS defect condition whenever it receives either the Framed or Unframed All Ones
pattern for at least 42ms.
11
Framed All Ones Pattern:The Receive DS1 Framer block will only declare the AIS
defect condition whenever it receives the Framed All Ones Pattern for at least 42ms.
267
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 399: T1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
CRC-6
Source
Select
Framing Bits
Source
Select
R/O
R/W
R/W
R/W
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:2] - Reserved
BIT 1 - CRC-6 Source Select:
This READ/WRITE bit-field is used to specify the source of the CRC-6 bits, within the outbound DS1 data-stream.
` 0 = Configures the Transmit DS1 Framer block to internally compute and insert the CRC-6 bits within the outbound
DS1 data-stream.
` 1 = Configures the Transmit DS1 Framer block to externally accept data from the TxDS1DATA_n input pin (or from
upstream circuitry) and to insert this data into the CRC-6 bit-fields within the outbound DS1 data-stream.
BIT 0 - Framing Bits Source Select:
This READ/WRITE bit-field is used to specify the source of the Framing bits, within the outbound DS1 data-stream.
` 0 = Configures the Transmit DS1 Framer block to internally generate and insert the Framing bits within the outbound
DS1 data-stream
` 1 = Configures the Transmit DS1 Framer block to externally accept data from the TxDS1DATA_n input pin (or from
upstream circuitry) and to insert this data into the Framing bit-fields within the outbound DS1 data-stream.
TABLE 400: T1 FRAMER BLOCK - TRANSMIT DATA LINK SELECT REGISTER (ADDRESS = 0XN10A, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
Reserved
BIT 5
BIT 4
Transmit Data Link Bandwidth[1:0]
BIT 3
BIT 2
Transmit D/E Time Source
Select[1:0]
BIT 1
BIT 0
Transmit Data Link Source
Select[1:0]
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Reserved:
BIT [5:4] - Transmit Data Link Bandwidth[1:0]:
These two READ/WRITE bit-fields are used to select the Data Link Bandwidth (for the transmission of Data Link
Messages) within the outbound DS1 data-stream. Data Link Messages can be transmitted at a rate of either 4kHz or
2kHz.
The Relationship between Transmit Data Link Bandwidth[1:0] and the resulting Bits/Bandwidth
available for the transport of Data Link Messages within the outbound DS1 data-stream
TRANSMIT DATA LINK
BANDWIDTH[1:0]
RESULTING BANDWIDTH AVAILABLE TO TRANSPORT DATA LINK MESSAGES WITHIN
OUTBOUND DS1 DATA-STREAM
00
Data Link Bandwidth = 4kHzData Link Messages are being transported via every single
DL bit-field within the outbound DS1 data-stream
01
Data Link Bandwidth = 2kHz (Frames 1, 5, 9, ….)Data Link Messages are being transported via every other DL bit-field within the outbound DS1 data-stream.
268
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
The Relationship between Transmit Data Link Bandwidth[1:0] and the resulting Bits/Bandwidth
available for the transport of Data Link Messages within the outbound DS1 data-stream
TRANSMIT DATA LINK
BANDWIDTH[1:0]
RESULTING BANDWIDTH AVAILABLE TO TRANSPORT DATA LINK MESSAGES WITHIN
OUTBOUND DS1 DATA-STREAM
10
Data Link Bandwidth = 2kHz (Frames 3, 7, 11,…)Data Link Messages are being transported via every other DL bit-field within the outbound DS1 data-stream.
11
Do not use
NOTE: This bit-field only applies if the channel has been configured to operate in the T1-ESF Framing format.
BIT [3:2] - Transmit D/E Time Source Select[1:0]:
These two READ/WRITE bit-fields are used to specify the source of the data that is to be transported via the
D/E time-slots within the outbound Transmit DS1 Data-stream.
The Relationship between Transmit D/E Time Source Select[1:0] and the resulting source of the D/ETime-Slot data within the outbound DS1 data-stream
TRANSMIT D/E TIME SOURCE
SELECT[1:0]
SOURCE FOR TRANSMIT D/E TIME-SLOT DATA
00
Upstream Circuitry (for Aggregation Applications) or the TxDS1DATA_n input (for
28-Channel DS1 Framer/LIU Combo Mode applications).
01
The Transmit LAPD Controller Block
10
Reserved - Do NOT Use
11
NOTE: These two register bits are only active if the user has configured one of the Time-Slots (within the outbound
DS1 data-stream) to function as the D/E Channel.
BIT [1:0] - Transmit Data Link Source Select[1:0]:
These two READ/WRITE bit-fields are used to specify the source for the data that will be transported via the Data Link
bits, within the outbound DS1 data-stream.
The Relationship between Transmit Data Link Source Select[1:0] and the Resulting source of the
data (which is to be transported via the Data Link bits, within the outbound DS1 data-stream)
TRANSMIT DATA LINK
SOURCE SELECT[1:0]
RESULTING SOURCE OF DATA LINK DATA
00
Transmit LAPD Controller Block (within the Transmit DS1 Framer block)
01
Upstream Circuitry (for Aggregation Applications) or the TxDS1DATA_n input (for
28-Channel DS1 Framer/LIU Combo Mode Applications)
10
Reserved
11
Data Link Bits are each Forced to 1.
269
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 401: T1 FRAMER BLOCK - FRAMING CONTROL REGISTER (ADDRESS = 0XN10B, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Reframe
Framing with
CRC
Checking
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
1
0
0
0
0
0
0
LOF Tolerance[2:0]
BIT 1
BIT 0
LOF Range[2:0]
BIT7 - Reframe:
This READ/WRITE bit-field is used to command a Reframe to the Receive DS1 Framer block. A 0 to 1 transition (within
this bit-field) will force the Receive DS1 Framer block to restart the frame synchronization process. The Receive DS1
Framer block will automatically clear this bit-field to 0 once it has reacquired frame synchronization with the incoming
DS1 data-stream.
BIT6 - Framing with CRC Checking:
This READ/WRITE bit-field is used to configure the Receive DS1 Framer block to also include checking for correct CRC6 values as a part of In-Frame Declaration criteria. More specifically, if the user enables this feature, then the Receive
DS1 Framer block will also check and verify that the incoming DS1 data-stream contains correct CRC data, prior to
declaring the In-Frame condition.
` 0 = CRC Verification is NOT included in the Framing Alignment process.
` 1 = The Receive DS1 Framer block will also check for correct CRC values prior to declaring the In-Frame condition.
BIT [5:3] - LOF Tolerance[2:0]:
NOTE: These READ/WRITE bit-fields along with the LOF Range[2:0] bit-fields are used to define the LOF Defect
Declaration criteria. The Receive DS1 Framer block will declare the LOF defect condition anytime it detects
LOF_Tolerance[2:0](or more) framing bit errors, within any sliding window (consisting of LOF_Range[2:0]
framing The recommended value for LOF_Tolerance[2:0] is 2.
BIT [2:0] - LOF Range[2:0]:
These READ/WRITE bit-fields along with the LOF_Tolerance[2:0] bit-fields are used to define the LOF Defect
Declaration criteria. The Receive DS1 Framer block will declare the LOF defect condition anytime it detects
LOF_Tolerance[2:0] (or more) framing bit errors, within any sliding window (consisting of LOF_Range[2:0] framing
alignments) within the incoming DS1 data-stream.
TABLE 402: T1 FRAMER BLOCK - RECEIVE SIGNALING & DATA LINK SELECT REGISTER (ADDRESS = 0XN10C,
WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
Reserved
BIT 5
BIT 4
Receive Data Link Bandwidth[1:0]
BIT 3
BIT 2
Receive D/E Time-Slot Destination Select[1:0]
BIT 1
BIT 0
Receive Data-Link Destination Select[1:0]
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Reserved:
BIT [5:4] - Received Data Link Bandwidth[1:0]:
These two READ/WRITE bit-fields is used to select the Data Link Bandwidth (for the reception of Data Link Messages)
within the incoming DS1 data-stream. Data Link Messages can be received at a rate of either 4kHz or 2kHz.
270
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
The Relationship between Receive Data Link Bandwidth[1:0] and the resulting Bits/Bandwidth
available for the transport of Data Link Messages within the incoming DS1 data-stream
RESULTING BANDWIDTH AVAILABLE TO TRANSPORT DATA LINK MESSAGES
WITHIN INCOMING DS1 DATA-STREAM
RECEIVE DATA LINK BANDIDTH[1:0]
00
Data Link Bandwidth = 4kHzData Link Messages are being transported via
every single DL bit-field within the incoming DS1 data-stream
01
Data Link Bandwidth = 2kHz (Frames 1, 5, 9, ….)Data Link Messages are
being transported via every other DL bit-field within the incoming DS1 datastream.
10
Data Link Bandwidth = 2kHz (Frames 3, 7, 11,…)Data Link Messages are
being transported via every other DL bit-field within the incoming DS1 datastream.
11
Do not use
NOTE: This bit-field only applies if the channel has been configured to operate in the T1-ESF Framing format.
BIT [3:2] - Receive D/E Time-Slot Destination Select[1:0]:
These two READ/WRITE bit-fields are used to specify the source of the data that is to be transported via the D/E timeslots within the incoming Receive DS1 Data-stream.
The Relationship between Receive D/E Time Source Select[1:0] and the resulting source of the D/ETime-Slot data within the incoming DS1 data-stream
RECEIVE D/E TIME SOURCE
SELECT[1:0]
DESTINATION OF THE INCOMING RECEIVE D/E TIME-SLOT DATA
00
Downstream Circuitry (for Aggregation Applications) or the RxDS1DATA_n output
(for 28-Channel DS1 Framer/LIU Combo Mode applications).
01
The Receive LAPD Controller Block
10
Reserved - Do NOT Use
11
NOTE: These two register bits are only active if the user has configured one of the Time-Slots (within the incoming DS1
data-stream) to function as the D/E Channel.
BIT [1:0] - Receive Data Link Destination Select[1:0]:
These two READ/WRITE bit-fields are used to specify the source for the data that will be transported via the
Data Link bits, within the incoming DS1 data-stream.
The Relationship between Receive Data Link Source Select[1:0] and the Resulting source of the data
(which is to be transported via the Data Link bits, within the incoming DS1 data-stream)
TRANSMIT DATA LINK
SOURCE SELECT[1:0]
RESULTING DESTINATION OF DATA LINK DATA
00
Receive LAPD Controller Block (within the Receive DS1 Framer block)
01
Downstream Circuitry (for Aggregation Applications) or the RxDS1DATA_n output (for
28-Channel DS1 Framer/LIU Combo Mode Applications)
10
Reserved
11
Data Link Bits are ignored
271
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 403: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 0 (ADDRESS = 0XN10D, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive
Signaling
Change Channel 0
Receive
Signaling
Change Channel 1
Receive
Signaling
Change Channel 2
Receive
Signaling
Change Channel 3
Receive
Signaling
Change Channel 4
Receive
Signaling
Change Channel 5
Receive
Signaling
Change Channel 6
Receive
Signaling
Change Channel 7
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Signaling Change - Channel n=[0:7]:
These RESET-upon-READ bit-fields indicate whether the Channel Associated Signaling data associated with TimeSlots 0 through 7 (within the incoming DS1 data-stream) has changed since the last read of this register.
` 0 = Indicates that CAS data (for Time-Slots 0 through 7) has NOT changed since the last read of this register.
` 1 = Indicates that CAS data (for Time-Slots 0 through 7) has changed since the last read of this register.
NOTE: This register is only active if the incoming DS1 data-stream is using Channel Associated Signaling.
TABLE 404: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 1 (ADDRESS = 0XN10E, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive
Signaling
Change Channel 8
Receive
Signaling
Change Channel 9
Receive
Signaling
Change Channel 10
Receive
Signaling
Change Channel 11
Receive
Signaling
Change Channel 12
Receive
Signaling
Change Channel 13
Receive
Signaling
Change Channel 14
Receive
Signaling
Change Channel 15
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Signaling Change - Channel n=[8:15]:
These RESET-upon-READ bit-fields indicate whether the Channel Associated Signaling data associated with TimeSlots 8 through 15 (within the incoming DS1 data-stream) has changed since the last read of this register.
` 0 = Indicates that CAS data (for Time-Slots 8 through 15) has NOT changed since the last read of this register.
` 1 = Indicates that CAS data (for Time-Slots 8 through 15) has changed since the last read of this register.
TABLE 405: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 2 (ADDRESS = 0XN10F, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive
Signaling
Change Channel 16
Receive
Signaling
Change Channel 17
Receive
Signaling
Change Channel 18
Receive
Signaling
Change Channel 19
Receive
Signaling
Change Channel 20
Receive
Signaling
Change Channel 21
Receive
Signaling
Change Channel 22
Receive
Signaling
Change Channel 23
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - Receive Signaling Change - Channel n=[16:23]:
These RESET-upon-READ bit-fields indicate whether the Channel Associated Signaling data associated with TimeSlots 16 through 23 (within the incoming DS1 data-stream) has changed since the last read of this register.
272
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 0 = Indicates that CAS data (for Time-Slots 16 through 23) has NOT changed since the last read of this register.
` 1 = Indicates that CAS data (for Time-Slots 16 through 23) has changed since the last read of this register.
NOTE: This register is only active if the incoming DS1 data-stream is using Channel Associated Signaling.
TABLE 406: T1 FRAMER BLOCK - RECEIVE EXTRA-BITS REGISTER (ADDRESS = 0XN112, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
In Frame
State
BIT 2
BIT 1
BIT 0
Reserved
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT7 - In Frame State:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently declaring the In-Frame
condition within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block is currently declaring the LOF (Loss of Frame) defect condition.
` 1 = Indicates that the Receive DS1 Framer block is currently declaring itself to be in the In-Frame condition.
BIT [6:0] - Reserved
TABLE 407: T1 FRAMER BLOCK - DATA LINK CONTROL REGISTER (ADDRESS = 0XN113, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved
MOS Abort
Disable
Rx_FCS_DI
S
AutoRx
Tx_ABORT
Tx_IDLE
Tx_FCS_EN
MOS/BOS
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reserved
BIT6 - MOS Abort Disable:
This bit is used to either enable or disable the automatic MOS abort feature within the transmit HDLC controller. If the
user enables this feature, then the transmit HDLC controller will automatically transmit the abort sequence (e.g., a zero
followed by a string of 7 consecutive 1's) whenever it abruptly transitions from transmitting a MOS type of message to
transmitting a BOS type of message.
` 0 = Enables the Automatic MOS Abort feature
` 1 = Disabled
BIT 5 - Receive Frame Check Sequence Disable:
This bit is used to configure the receive HDLC controller to compute and verify the FCS value within each incoming
LAPD message frame.
` 0 = Enables FCS Verification
` 1 = Disabled
BIT 4 - Auto Receive:
This bit configures the receive HDLC controller to discard any incoming BOS or LAPD message frame that exactly
match which is currently stored in the receive HDLC buffer.
` 0 = Disabled
` 1 = Enables this auto discard feature
BIT 3 - Transmit Abort:
This bit configures the transmit HDLC controller to transmit an abort sequence (string of 7 or more consecutive 1's) to
273
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
the remote terminal.
` 0 = Disabled
` 1 = Transmit the abort sequence
BIT 2 - Transmit Idle (Flag Sequence Byte):
This bit configures the transmit HDLC controller to unconditionally transmit a repeating string of flag sequence octets
(0x7E) in the data link channel to the remote terminal. In normal conditions, the transmit HDLC controller will repeatedly
transmit the flag sequence octet whenever there is no MOS message to transmit to the remote terminal equipment.
However, if the user invokes this transmit idle sequence feature, then the transmit HDLC controller will
UNCONDITIONALLY transmit a repeating stream of the flag sequence octet (thereby overwriting all outbound MOS
data link messages).
` 0 = Disabled
` 1 = Transmit a repeating string of Flag Sequence Octets (0x7E)
NOTE: This bit is ignored if the transmit HDLC controller is operating in the BOS mode (bit 0 within this register is set to
0).
BIT 1 - Transmit Frame Check Sequence Enable:
This bit is used to configure the transmit HDLC controller to compute and append FCS octets to the back end of each
outbound MOS data link message.
` 0 = Disabled
` 1 = Compute and append the FCS octets to the back end of each outbound MOS data link message
NOTE: This bit is ignored if the transmit HDLC controller ahs been configured to operate in the BOS mode - BIT 0
within this register is set to 0).
BIT 0 - MOS / BOS:
This bit is used to configure transmit and receive the HDLC to be transmitting and receiving either BOS (bit oriented
signaling) or MOS (message oriented signaling) frames.
` 0 = Transmit and Receive BOS Messages
` 1 = Transmit and Receive MOS Messages
TABLE 408: T1 FRAMER BLOCK - TRANSMIT DATA LINK CONTROL REGISTER (ADDRESS = 0XN114, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
TxHDLC
BUFAVAIL
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit HDLC Message Byte Count
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Transmit HDLC Buffer Available:
This bit has different functions depending upon whether the user is writing to or reading from this register.
If User is Writing Data Into This Register Bit
` 0 = Configures the transmit HDLC controller to read out and transmit the data, residing within the transmit HDLC buffer
0 via the data link channel to the remote terminal equipment.
` 1 = Configures the transmit HDLC controller to read out and transmit the data, residing within the transmit HDLC buffer
1 via the data link channel to the remote terminal equipment.
If User is Reading Data From This Register Bit
` 0 = Indicates that transmit buffer 0 is the next available buffer. In this case, to write in the contents of a new outbound
data link message into the transmit HDLC message buffer, the message should be written into buffer 0.
` 1 = Indicates that transmit buffer 1 is the next available buffer. In this case, to write in the contents of a new outbound
data link message into the transmit HDLC message buffer, the message should be written into buffer 1.
274
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: If one of these transmit HDLC buffers contain a message which has yet to be completely read in and processed
for transmission by the transmit HDLC controller, then this bit will automatically reflect the value corresponding
to the next available buffer when it is read. Changing this bit to the in use buffer is not permitted.
BIT [6:0] - Transmit HDLC Message Byte Count:
The exact function of these bits depends on whether the transmit HDLC controller is configured to transmit MOS or BOS
messages to the remote terminal equipment.
In BOS Mode:
These bit fields contain the number of repetitions the BOS message must be transmitted before the transmit HDLC
controller generates the transmit end of transfer (TxEOT) interrupt and halts transmission. If these fields are set to
0000000, then the BOS message will be transmitted for an indefinite number of times.
In MOS Mode:
These bit fields contain the length, in number of octets, of the message to be transmitted. The length of MOS message
specified in these bits include header bytes such as the SAPI, TEI, and Control Field. However, it does not include the
FCS bytes.
TABLE 409: T1 FRAMER BLOCK - RECEIVE DATA LINK CONTROL REGISTER (ADDRESS = 0XN115, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
RBUFPTR
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive HDLC Message Byte Count
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Receive HDLC Buffer Pointer:
This bit identifies which receive HDLC buffer contains the most recently received HDLC message.
` 0 = Indicates that receive HDLC buffer 0 contains the contents of the most recently received HDLC message.
` 1 = Indicates that receive HDLC buffer 1 contains the contents of the most recently received HDLC message.
BIT [6:0] - Receive HDLC Message Byte Count:
The exact function of these bits depends on whether the receive HDLC controller is configured to receive MOS or BOS
messages.
In BOS Mode:
These seven bits contain the number of repetitions the BOS message must be received before the receive HDLC
controller generates the receive end of transfer (RxEOT) interrupt. If these bits are set to 0000000, the message will be
received indefinitely and no RxEOT interrupt will be generated.
In MOS Mode:
These seven bits contain the size in bytes of the HDLC message that has been received and written into the receive
HDLC buffer. The length of MOS message shown in these bits include header bytes such as the SAPI, TEI, Control
Field, and the FCS bytes.
TABLE 410: T1 FRAMER BLOCK - CUSTOMER INSTALLATION ALARM GENERATION REGISTERS (ADDRESS =
0XN11C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
Customer Installation Alarm
Generation[1:0]
BIT 1
BIT 0
Customer Installation Alarm
Detection[1:0]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [3:2] - CI Alarm Transmit (Only in ESF)
These two bits are used to enable or disable AIS-CI or RAI-CI generation in T1 ESF mode only. AIS-CI and RAI-CI are
275
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
intended for use in a network to differentiate between an issue within the network or the Customer Installation (CI).
AIS-CI
AIS-CI is an all ones with an embedded signature of 01111100 11111111 (right-to-left) which recurs at 386 bit intervals
in the DS-1 signal.
RAI-CI
Remote Alarm Indication (RAI-CI) is a repetitive pattern with a period of 1.08 seconds. It comprises 0.99 seconds of RAI
message (00000000 11111111 right-to-left) and a 90 ms of RAI-CI signature (00111110 11111111 right-to-left) to form
an RAI-CI signal.
` 00/11 = Disabled
` 01 = Enables unframed AIS-CI alarm generation
` 10 = Enables RAI-CI alarm generation
BIT [1:0] - CI Alarm Detect (Only in ESF)
These two bits are used to enable or disable AIS-CI or RAI-CI alarm detection in T1 ESF only.
` 00/11 = Disabled
` 01 = Enables unframed AIS-CI alarm detection
` 10 = Enables RAI-CI alarm detection
TABLE 411: T1 FRAMER BLOCK - DS1 TEST REGISTER - 2 (ADDRESS = 0XN121, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38)
BIT7
BIT6
Reset by
Register
BIT 5
BIT 4
BIT 3
Unused
PRBS
Switch
BIT 2
BIT 1
BER Control[1:0]
BIT 0
Unframed
PRBS
R/W
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - Reset by Register:
This READ/WRITE bit-field is used to execute a Software RESET to the T1/E1 Framer block, within a given channel.
` 0 = Configures the T1/E1 Framer block to operate normally.
` 1 = Configures the T1/E1 Framer block (of the corresponding channel) to operate in the Software RESET condition.
NOTE: Once the T1/E1 Framer block exits the Software RESET state, it will automatically clear this bit-field to 0.
BIT [6:4] - Reserved
These bits are reserved
BIT 3 - PRBS Switch:
This READ/WRITE bit-field is used to specify the direction that the PRBS Pattern will be transmitted.
` 0 = PRBS Pattern will be generated and transmitted towards Transmit Output of the Transmit DS1 Framer block. This
PRBS Pattern will also be monitored at the Receive Input of the corresponding Receive DS1 Framer block.
` 1 = PRBS Pattern will be generated and transmitted towards the System Side Output of the Receive DS1 Framer
block. This PRBS Pattern will also be monitored at the System-Side Input of the Transmit DS1 Framer block.
BIT [2:1] BER Control[1:0]:
These READ/WRITE bit-fields is used to configure the PRBS Generator (within the Transmit DS1 Framer
block) to insert BIT-Errors.
Resulting Errors Generated by the PRBS Generator
BER CONTROL[1:0]
00
RESULTING ERRORS GENERATED BY THE PRBS GENERATOR
No Bit Error Inserted
276
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Resulting Errors Generated by the PRBS Generator
BER CONTROL[1:0]
RESULTING ERRORS GENERATED BY THE PRBS GENERATOR
01
1 Erred bit per 1,000 bits is inserted
10
1 Erred bit per 1,000,000 bits is inserted
11
No Bit Error Inserted
BIT 0 - Unframed PRBS:
This READ/WRITE bit-field is used to configure the Transmit DS1 Framer block to generate and transmit either a framed
or unframed PRBS Pattern. Likewise, this bit-field also configures the corresponding Receive DS1 Framer block to
expect either a framed or unframed PRBS pattern.
` 0 = Transmit and Receive DS1 Framer block will handle framed PRBS Pattern.
` 1 = Transmit and Receive DS1 Framer block will handle unframed PRBS Pattern.
TABLE 412: T1 FRAMER BLOCK - DS1 TEST REGISTER - 1 (ADDRESS = 0XN123, WHERE N RANGES IN VALUE FROM
0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PRBS Type
Error Insert
Data Invert
Receive
PRBS Lock
Receive
PRBS
Enable
Transmit
PRBS
Enable
Receive DS1
By Pass
Transmit
DS1 By Pass
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT7 - PRBS Type:
This READ/WRITE bit-field is used to specify the type of random pattern that the PRBS Generator and PRBS Receiver
will handle.
` 0 = A PRBS Pattern with the Polynomial of X^15 + X^14 + 1.
` 1 = A QRTS Pattern
BIT6 - Error Insert:
This READ/WRITE bit-field is used to configure the PRBS Generator to insert a single bit-error into the outbound PRBS
data-stream.
` A 0 to 1 transition, within this bit-field causes the PRBS Generator to insert a single bit-error into the outbound PRBS
data-stream.
BIT 5 - Data Invert:
This READ/WRITE bit-field is used to (1) configure the PRBS Generator to invert all of its outbound traffic (as it
generates and transmits this data), and (2) configures the PRBS Receiver to invert all of the incoming PRBS pattern
data prior to processing.
` 0 = No Inversion by either the PRBS Generator or the PRBS Receiver
` 1 = Configures Inversion by both the PRBS Generator and PRBS Receiver
BIT 4 - Receive PRBS Lock:
This READ-ONLY bit-field indicates whether or not the PRBS Receiver is currently declaring PRBS Lock with the
incoming PRBS data-stream.
` 0 = PRBS Receiver is NOT currently declaring PRBS Lock.
` 1 = PRBS Receiver is CURRENTLY declaring PRBS Lock.
BIT 3 - Receive PRBS Detection/Generation Enable:
This READ/WRITE bit-field is used to either enable or disable the PRBS Receiver.
` 0 = Disables the PRBS Receiver
277
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
` 1 = Enables the PRBS Receiver
BIT 2 - Transmit PRBS Generation Enable:
This READ/WRITE bit-field is used to either enable or disable the PRBS Generator.
` 0 = Disables the PRBS Generator
` 1 = Enables the PRBS Generator
BIT 1 - Receive DS1 By-Pass:
This bits enables the receive T1 Framer Bypass Mode
` 0 = Disabled
` 1 = Enables Receive Framer Bypass
BIT 0 - Transmit DS1 By-Pass:
This bits enables the transmit T1 Framer Bypass Mode
` 0 = Disabled
` 1 = Enables Transmit Framer Bypass
TABLE 413: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 0(ADDRESS = 0XN124, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
Receive Loop-Back Code
Activation Length[1:0]
BIT 5
BIT 4
BIT 3
Receive Loop-Back Code
Deactivation Length[1:0]
BIT 2
Transmit Loop-back Code
Length[1:0]
BIT 1
BIT 0
Framed
Loop-Back
Code
Loop-Back
Automatically
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Receive Loop-Back Code Activation Length[1:0]:
These two READ/WRITE bit-fields are used to specify the length of the loop-back activation code that the Receive DS1
Framer block will will use (for Code 0).
Receive Loop-Back Code Activation Length
RECEIVE LOOP-BACK CODE
ACTIVATION LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
10
6 Bit Sequence
11
7 Bit Sequence
BIT [5:4] - Receive Loop-Back Code Deactivation Length[1:0]:
These two READ/WRITE bit-fields are used to specify the length of the loop-back deactivation code that the Receive
DS1 Framer block will use (for Code 0).
Receive Loop-Back Code De-activation Length
RECEIVE LOOP-BACK CODE
DE-ACTIVATION
LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
278
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Receive Loop-Back Code De-activation Length
RECEIVE LOOP-BACK CODE
DE-ACTIVATION
LENGTH[1:0]
LENGTH
10
6 Bit Sequence
11
7 Bit Sequence
BIT [3:2] - Transmit Loop-Back Code Length[1:0]:
These two READ/WRITE bit-fields are used to specify the length of the loop-back codes that the Transmit DS1 Framer
block will transmit to the remote terminal equipment anytime the user commands it to transmit the User-Specified Loopcode to the remote terminal equipment..
Transmit Loop-Back Code Length
TRANSMIT LOOP-BACK
CODE LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
10
6 Bit Sequence
11
7 Bit Sequence
BIT 1 - Framed Loop-Back Code:
This READ/WRITE bit-field is used to configure the Transmit DS1 Framer and Receive DS1 Framer blocks to transmit
and detect either framed or un-framed loop-codes (for Code 0)..
` 0 = Configures the Transmit DS1 Framer block to transmit loop-codes within an unframed DS1 data-stream, and
configures the Receive DS1 Framer block to detect loop-codes within an unframed DS1 data-stream.
` 1 = Configures the Transmit DS1 Framer block to transmit loop-codes within a framed DS1 data-stream, and
configures the Receive DS1 Framer block to detect loop-codes within a framed DS1 data-stream.
BIT 0 - Loop-Back Automatically:
This READ/WRITE bit-field is used to configure the Channel to operate in the Auto Loop-back Mode. If the user
configures the Channel to operate in the Auto Loop-back Mode, then all of the following is TRUE.
•
The DS1 Framer block will automatically enter the Remote Loop-back Mode anytime the Receive DS1
Framer block detects and validates the Loop-up code within the incoming DS1 data-stream.
•
The DS1 Framer block will automatically exit the Remote Loop-back Mode anytime the Receive DS1 Framer
block detects and validates the Loop-Down code within the incoming DS1 data-stream.
` 0 = Does not configure the Channel to operate in the Auto Loop-Back Mode.
` 1 = Configures the Channel to operate in the Auto Loop-Back Mode
TABLE 414: T1 FRAMER BLOCK - TRANSMIT LOOP-BACK CODE REGISTER (ADDRESS = 0XN125, WHERE N RANGES
IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Transmit Loop-back Code[6:0]
BIT 0
Transmit
Loop-back
Code Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
279
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT [7:1] - Transmit Loop-back Code[6:0]:
These READ/WRITE bit-fields is used to specify the loop-back code that the Transmit DS1 Framer block will transmit
(to the remote terminal equipment) whenever the user commands it to do so by setting BIT 0 (Transmit Loop-Back Code
Enable) to 1, within this register.
BIT 0 - Transmit Loop-back Code Enable:
This READ/WRITE bit-field is used to command the Transmit DS1 Framer block to transmit the Loop-back
Code (which has been written into Bits 7 through 1, within this register) to the remote terminal.
` 0 = Configures the Transmit DS1 Framer block to NOT transmit the Loop-back Code to the remote terminal
equipment.
` 1 = Configures the Transmit DS1 Framer block to transmit the Loop-back code to the remote terminal equipment.
NOTE: The Transmit DS1 Framer block will repeatedly transmit the loop-back code for the duration that this bit-field is
set to 1.
TABLE 415: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 0 (ADDRESS
= 0XN126, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Receive Loop-Back Activation Code[6:0]
BIT 0
Receive Activation LoopBack Code
Detect
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
BIT [7:1] - Receive Loop-Back Activation Code[6:0]:
These seven (7) READ/WRITE bit-fields are used to specify/define one of the threee possible loop-code patterns that
the Receive DS1 Framer block should respond to, and interpret as being the Loop-Up (or Loop-Back Activate) code.
NOTES:
1.
These READ/WRITE bit-fields are only active if BIT 0 (Receive Activation Loop-Back Code Detect Enable) has
been set to 1.
2.
The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This
particular register applies to "Code 0".
BIT 0 - Receive Activation Loop-Back Code Detect Enable:
This READ/WRITE bit-field is used to either enable or disable the Receive DS1 Framer block for Loop-Back Activation
Code detection for Code 0. If the user enables the Receive DS1 Framer block for Loop-Back Activation Code detection
for Code 0, then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will also begin to check
the incoming DS1 data-stream for the presence of the Loop-Back Activation Code (which has been defined in Bits 7
through 1 within this particular register).
` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the
Loop-Back Activation code.
` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the LoopBack Activation code.
280
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 416: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 0
(ADDRESS = 0XN127, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Receive Loop-Back Deactivation Code[6:0]
BIT 0
Receive
Deactivation
Loop-Back
Code Detect
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
BIT [7:1] - Receive Loop-Back Deactivation Code[6:0]:
These seven (7) READ/WRITE bit-fields are used to specify/define one of the three possible loop-code pattern that the
Receive DS1 Framer block should respond to, and interpret as being the Loop-Down (or Loop-Back Deactivate) code.
NOTES:
1.
These READ/WRITE bit-fields are only active if BIT 0 (Receive Deactivation Loop-Back Code Detect Enable) has
been set to 1.
2.
The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as Code 0, Code 1"and Code 2 within this document. This
particular register applies to "ode 0.
BIT 0 - Receive Deactivation Loop-Back Code Detect Enable:
This READ/WRITE bit-field is used to either enable or disable the Receive DS1 Framer block for Loop-Back
Deactivation Code detection for Code 0. If the user enables the Receive DS1 Framer block for Loop-Back Deactivation
Code detection for Code 0, then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will
also begin to check the incoming DS1 data-stream for the presence of the Loop-Back Deactivation Code (which has
been defined in Bits 7 through 1 within this particular register).
` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the
Loop-Back Deactivation code.
` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the LoopBack Deactivation code.
page 695 of word
TABLE 417: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 1 (ADDRESS = 0XN12A, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
Receive Loop-Back Code
Activation Length[1:0]
BIT 5
BIT 4
BIT 3
Receive Loop-Back Code
Deactivation Length[1:0]
BIT 2
Unused
BIT 1
BIT 0
Framed
Loop-Back
Code
Unused
R/W
R/W
R/W
R/W
R/O
R/O
R/W
R/O
0
0
0
0
0
0
0
0
Bits [7:6] - Receive Loop-Back Code Activation Length[1:0]:
These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back activation" code that
the Receive DS1 Framer block will use (for Code 1), as depicted below in Table _.
281
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
RECEIVE LOOP-BACK CODE ACTIVATION
LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
10
6 Bit Sequence
11
7 Bit Sequence
Bits [5:4] - Receive Loop-Back Code Deactivation Length[1:0]:
These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back deactivation" code that the
Receive DS1 Framer block will use (for Code 1), as depicted below in Table _.
RECEIVE LOOP-BACK CODE DE-ACTIVATION
LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
10
6 Bit Sequence
11
7 Bit Sequence
Bits [3:2] - Reserved:
Bit 1 - Framed Loop-Back Code:
This READ/WRITE bit-field permits the user to configure the Transmit DS1 Framer and Receive DS1 Framer blocks to
transmit and detect either "framed" or "un-framed" loop-codes (for Code 1), as depicted below.
` 0 = Configures the Transmit DS1 Framer block to transmit loop-codes within an "unframed" DS1 data-stream, and
configures the Receive DS1 Framer block to detect loop-codes within an "unframed" DS1 data-stream.
` 1 = Configures the Transmit DS1 Framer block to transmit loop-codes within a "framed" DS1 data-stream, and
configures the Receive DS1 Framer block to detect loop-codes within a "framed" DS1 data-stream.
Bit 0 - Reserved:
TABLE 418: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 1 (ADDRESS
= 0XN12B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Receive Loop-Back Activation Code[6:0]
BIT 0
Receive
Activation
Loop-Back
Code Detect
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
Bits [7:1] - Receive Loop-Back Activation Code[6:0]:
These seven (7) READ/WRITE bit-fields are used to specify/define one of the three possible "loop-code" patterns that
the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Up" (or Loop-Back Activate) code.
NOTES:
282
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTES:
1.
These READ/WRITE bit-fields are only active if Bit 0 (Receive Activation Loop-Back Code Detect Enable) has
been set to "1".
2.
The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This
particular register applies to "Code 1".
Bit 0 - Receive Activation Loop-Back Code Detect Enable:
This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back
Activation" Code detection for "Code 1". If the user enables the Receive DS1 Framer block for "Loop-Back Activation"
Code detection (for Code 1), then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will
also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Activation" Code (which has been
defined in Bits 7 through 1 within this particular register).
` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the
"Loop-Back Activation" code.
` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Activation" code.
TABLE 419: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 1
(ADDRESS = 0XN12C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Receive Loop-Back Deactivation Code[6:0]
BIT 0
Receive
Deactivation
Loop-Back
Code Detect
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
Bits [7:1] - Receive Loop-Back Deactivation Code[6:0]:
These seven (7) READ/WRITE bit-fields permits the user to specify/define one of the three possible "loop-code"
patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Down" (or Loop-Back
Deactivate) code.
NOTES:
1.
These READ/WRITE bit-fields are only active if Bit 0 (Receive Deactivation Loop-Back Code Detect Enable) has
been set to "1".
2.
The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This
particular register applies to "Code 1".
Bit 0 - Receive Deactivation Loop-Back Code Detect Enable:
This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back
Deactivation" Code detection for "Code 1". If the user enables the Receive DS1 Framer block for "Loop-Back
Deactivation" Code detection (for Code 1), then the Receive DS1 Framer block (as it is receiving its incoming DS1 datastream) will also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Deactivation" Code
(which has been defined in Bits 7 through 1 within this particular register).
` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the
"Loop-Back Deactivation" code.
` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Deactivation" code.
283
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 420: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 2 (ADDRESS = 0XN12D, WHERE
N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
Receive Loop-Back Code
Activation Length[1:0]
BIT 4
BIT 3
Receive Loop-Back Code
Deactivation Length[1:0]
BIT 2
Unused
BIT 1
BIT 0
Framed
Loop-Back
Code
Unused
R/W
R/W
R/W
R/W
R/O
R/O
R/W
R/O
0
0
0
0
0
0
0
0
Bits [7:6] - Receive Loop-Back Code Activation Length[1:0]:
These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back activation" code that the
Receive DS1 Framer block will use (for Code 2), as depicted below in Table _.
RECEIVE LOOP-BACK CODE
ACTIVATION LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
10
6 Bit Sequence
11
7 Bit Sequence
Bits [5:4] - Receive Loop-Back Code Deactivation Length[1:0]:
These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back deactivation" code that the
Receive DS1 Framer block will use (for Code 2), as depicted below in Table _.
RECEIVE LOOP-BACK CODE DE-ACTIVATION
LENGTH[1:0]
LENGTH
00
4 Bit Sequence
01
5 Bit Sequence
10
6 Bit Sequence
11
7 Bit Sequence
Bits [3:2] - Reserved:
Bit 1 - Framed Loop-Back Code:
This READ/WRITE bit-field permits the user to configure the Transmit DS1 Framer and Receive DS1 Framer blocks to
transmit and detect either "framed" or "un-framed" loop-codes (for Code 2), as depicted below.
` 0 = Configures the Transmit DS1 Framer block to transmit loop-codes within an "unframed" DS1 data-stream, and
configures the Receive DS1 Framer block to detect loop-codes within an "unframed" DS1 data-stream.
` 1 = Configures the Transmit DS1 Framer block to transmit loop-codes within a "framed" DS1 data-stream, and
configures the Receive DS1 Framer block to detect loop-codes within a "framed" DS1 data-stream.
Bit 0 - Reserved:
284
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 421: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 2 (ADDRESS
= 0XN12E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Receive Loop-Back Activation Code[6:0]
Receive Activation
Loop-Back Code
Detect Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
Bits [7:1] - Receive Loop-Back Activation Code[6:0]:
These seven (7) READ/WRITE bit-fields permits the user to specify/define one of the three possible "loop-code"
patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Up" (or Loop-Back
Activate) code.
NOTES:
1.
These READ/WRITE bit-fields are only active if Bit 0 (Receive Activation Loop-Back Code Detect Enable) has
been set to "1".
2.
The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This
particular register applies to "Code 2".
Bit 0 - Receive Activation Loop-Back Code Detect Enable:
This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back
Activation" Code detection for "Code 2". If the user enables the Receive DS1 Framer block for "Loop-Back Activation"
Code detection (for Code 2), then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will
also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Activation" Code (which has been
defined in Bits 7 through 1 within this particular register).
` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the
"Loop-Back Activation" code.
` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Activation" code.
TABLE 422: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 2
(ADDRESS = 0XN12F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Receive Loop-Back Deactivation Code[6:0]
BIT 0
Receive
Deactivation
Loop-Back
Code Detect
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
Bits [7:1] - Receive Loop-Back Deactivation Code[6:0]:
These seven (7) READ/WRITE bit-fields permits the user to specify/define one of the three possible "loop-code"
patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Down" (or Loop-Back
Deactivate) code.
NOTES:
1.
These READ/WRITE bit-fields are only active if Bit 0 (Receive Deactivation Loop-Back Code Detect Enable) has
been set to "1".
285
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
2.
The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This
particular register applies to "Code 2".
Bit 0 - Receive Deactivation Loop-Back Code Detect Enable:
This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back
Deactivation" Code detection for "Code 2". If the user enables the Receive DS1 Framer block for "Loop-Back
Deactivation" Code detection (for Code 2), then the Receive DS1 Framer block (as it is receiving its incoming DS1 datastream) will also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Deactivation" Code
(which has been defined in Bits 7 through 1 within this particular register).
` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the
"Loop-Back Deactivation" code.
` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Deactivation" code.
TABLE 423: T1 FRAMER BLOCK - TRANSMIT CHANNEL CONTROL REGISTER - T1 TIME SLOT # 0 (ADDRESS =
0XN300, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
Reserved
BIT 5
BIT 4
BIT 3
Transmit Zero Suppression[1:0]
BIT 2
BIT 1
BIT 0
Transmit Channel Conditioning[3:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - Reserved.
BIT [5:4] - Transmit Zero Suppression[1:0]:
BIT [3:0] - Transmit Channel Conditioning[3:0]:
These READ/WRITE bit-fields are used to specify how Time-Slot # 0 (within the Transmit DS1 signal is conditioned or
modified).
Transmit Channel Conditioning
TRANSMIT CHANNEL
CONDITIONING[3:0]
RESULTING CONDITIONING OF TIME-SLOT # 0
0000
The Input PCM data is unchanged (Normal Operation)
0001
All 8-bits of the PCM data are inverted
0010
The even bits of the PCM data are inverted
0011
The odd bits of the PCM data are inverted
0100
PCM Data is replaced with User Code Data
0101
PCM Data is replaced with the BUSY Code (0x7F)
0110
PCM Data is replaced with the VACANT Code (0xFF)
0111
PCM Data is replaced with the BUSY Time-Slot Pattern (0xE0 in the case of
Time-Slot # 0).
1000
PCM Data is replaced with the MUX Out of Frame (MOOF) Pattern (0x1A).
286
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 424: T1 FRAMER BLOCK - LAPD BUFFER 0 CONTROL REGISTER (ADDRESS = 0XN600 - 0XN640, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LAPD Buffer 0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] LAPD Buffer 0:
This register is used to transmit and receive LAPD messages within buffer 0 of the HDLC controller. Users should
determine the next available buffer by reading the BUFAVAL bit (BIT7 of the Transmit Data Link Byte Count Register
0xN114h). If buffer 0 is available, writing to buffer 0 will insert the message into the outgoing LAPD frame after the LAPD
message is sent and the data from the transmit buffer cannot be retrieved.
After detecting the receive end of transfer interrupt (RxEOT), users should read the RBUFPTR bit (bit 7 of the receive
data link byte count register 0xN115h) to determine which buffer contains the received LAPD message ready to be read.
If RBUFPTR bit indicates that buffer 0 is available to be read, reading buffer 0 continuously will retrieve the entire
received LAPD message.
NOTE: When writing to or reading from Buffer 0, the register is automatically incremented such that the entire 64 Byte
LAPD message can be written into or read from buffer 0 continuously.
TABLE 425: T1 FRAMER BLOCK - LAPD BUFFER 1 CONTROL REGISTER (ADDRESS = 0XN700 - 0XN740, WHERE N
RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LAPD Buffer 1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:0] LAPD Buffer 1:
This register is used to transmit and receive LAPD messages within buffer 1 of the HDLC controller. Users should
determine the next available buffer by reading the BUFAVAL bit (BIT7 of the Transmit Data Link Byte Count Register
0xN114h). If buffer 1 is available, writing to buffer 1 will insert the message into the outgoing LAPD frame after the LAPD
message is sent and the data from the transmit buffer cannot be retrieved.
After detecting the receive end of transfer interrupt (RxEOT), users should read the RBUFPTR bit (bit 7 of the receive
data link byte count register 0xN115h) to determine which buffer contains the received LAPD message ready to be read.
If RBUFPTR bit indicates that buffer 1 is available to be read, reading buffer 1 continuously will retrieve the entire
received LAPD message.
NOTE: When writing to or reading from Buffer 1, the register is automatically incremented such that the entire 64 Byte
LAPD message can be written into or read from buffer 1 continuously.
287
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 426: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER CODE 0 (ADDRESS = 0XNB0A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
AUXP
Pattern State
Change of
AUXP State
Interrupt
Status
CRC-4 to
Non CRC-4
Inter-networking
Status
Change of
CRC-4 to
Non-CRC-4
Inter-networking Status
Receive
Loop-Back
Activation
Status -Code
0
Receive
Loop-Back
Deactivation
Status -Code
0
Change of
Receive
Loop-Back
Activation
State
Interrupt
Status -Code
0
Change of
Receive
Loop-Back
Deactivation
State I
nterrupt
Status -Code
0
R/O
RUR
R/O
RUR
R/O
R/O
RUR
RUR
0
0
0
0
0
0
0
0
BIT7 - AUXP Pattern State:
This READ-ONLY register bit indicates whether or not the Receive DS1 Framer block is currently detecting the AUXP
pattern within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting the AUXP pattern within the incoming
DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting the AUXP pattern within the incoming DS1
data-stream.
BIT6 - Change of AUXP State Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has declared the Change of
AUXP State Interrupt since the last read of this register. The Receive DS1 Framer block will generate the Change of
AUXP State Interrupt in response to either of the following conditions.
•
Whenever it begins to detect the AUXP Pattern within the incoming DS1 data-stream, and
•
Whenever it ceases to detect the AUXP Pattern within the incoming DS1 data-stream.
` 0 = Indicates that the Change of AUXP Status Interrupt has NOT occurred since the last read of this register.
` 1 = Indicates that the Change of AUXP Status Interrupt has occurred since the last read of this register.r
BIT 5 - CRC-4 to Non-CRC-4 Internetworking Status:
BIT 4 - Change of CRC-4 to Non-CRC-4 Internetworking Status:
BIT 3 - Receive Loop-Back Activation Status -Code 0:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging)
the Loop-Up (or Loop-Back Activate) code (associated with "Code 0") within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the Loop-Back Activate
Code (associated with "Code 0") within the incoming DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Back Activate Code
(associated with "Code 0") within the incoming DS1 data-stream.
NOTE: The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This
particular register applies to "Code 0".
BIT 2 - Receive Loop-Back Deactivation Status - Code 0:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging)
the Loop-Down (or Loop-Back Deactivate) code (associated with Code 0) within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the Loop-Back Deactivate
Code (associated with "Code 0") within the incoming DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Back Deactivate Code
(associated with "Code 0") within the incoming DS1 data-stream.
BIT 1 - Change of Receive Loop-Back Activation State Interrupt Status - mCode 0:
288
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the Change
of Receive Loop-Back Activation State Interrupt, since the last read of this register. The Receive DS1 Framer block will
generate the Change of Receive Loop-Back Activation State Interrupt in response to either of the following events.
•
Whenever the Receive DS1 Framer block detects (and validates) the Loop-Back Activate Code (associated
with Code 0) within the incoming DS1 data-stream
•
Whenever the Receive DS1 Framer block ceases to detect the Loop-Back Activate code (associated with
Code 0) within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block has NOT generated the Change of Receive Loop-Back Activation
State Interrupt for Code 0 since the last read of this register.
` 1 = Indicates that the Receive DS1 Framer block has generated the Change of Receive Loop-Back Activation State
Interrupt for Code 0 since the last read of this register.
BIT 0 - Change of Receive Loop-Back Deactivation Status Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the Change
of Receive Loop-Back Deactivation State Interrupt (based upon loop-code Code 0), since the last read of this register.
The Receive DS1 Framer block will generate the Change of Receive Loop-Back Deactivation State Interrupt in
response to either of the following events.
•
Whenever the Receive DS1 Framer block detects (and validates) the Loop-Back Deactivate Code
(associated with Code 0) within the incoming DS1 data-stream
•
Whenever the Receive DS1 Framer block ceases to detect the Loop-Back Deactivate code (associated with
Code 0) within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block has NOT generated the Change of Receive Loop-Back Deactivation
State Interrupt for Code 0 since the last read of this register.
` 1 = Indicates that the Receive DS1 Framer block has generated the Change of Receive Loop-Back Deactivation State
Interrupt for Code 0 since the last read of this register.
TABLE 427: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE
0 (ADDRESS = 0XNB0B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Reserved
Change of
AUXP State
Interrupt
Enable
Reserved
Change of
CRC-4 to
Non-CRC-4
Inter-Networking
State
Interrupt
Enable
R/O
R/W
R/O
R/W
R/O
0
0
0
0
0
BIT 2
BIT 1
BIT 0
Change of
Receive
Loop-Back
Activation
Interrupt
Enable Code 0
Change of
Receive
Loop-Back
Deactivation
Interrupt
Enable Code 0
R/O
R/W
R/W
0
0
0
Reserved
BIT7 - Reserved:
BIT6 - Change of AUXP State Interrupt Enable:
This READ/WRITE bit-field is used to either enable or disable the Change of AUXP State Interrupt. If the user enables
the Change of AUXP State Interrupt, then the Receive DS1 Framer block will generate the Change of AUXP State
Interrupt in response to the following events.
•
Whenever it begins to detect the AUXP Pattern within the incoming DS1 data-stream, and
•
Whenever it ceases to detect the AUXP Pattern within the incoming DS1 data-stream.
` 0 = Disables the Change of AUXP State Interrupt.
` 1 = Enables the Change of AUXP State Interrupt
BIT 5 - Reserved
BIT 4 - Change of CRC-4 to Non-CRC-4 Internetworking Status Interrupt Enable:
289
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT [3:2] - Reserved
BIT 1 - Change of Receive Loop-Back Activation Interrupt Enable - Code 0:
This READ/WRITE bit-field is used to either enable or disable the Change of Receive Loop-Back Activation State
Interrupt, associated with Code 0. If the user enables the Change of Receive Loop-Back Activation State Interrupt, then
the Receive DS1 Framer block will generate the Change of Receive Loop-Back Activation State Interrupt in response
to the following events.
•
Whenever it detects and validates the Receive Loop-Back Activation Pattern (associated with Code 0) within
the incoming DS1 data-stream, and
•
Whenever it ceases to detect the Receive Loop-Back Activation Pattern (associated with Code 0) within the
incoming DS1 data-stream.
` 0 = Disables the Change of Receive Loop-Back Activation State Interrupt for loop-code Code 0.
` 1 = Enables the Change of Receive Loop-Back Activation State Interrupt for loop-code Code 0
BIT 0 - Change of Receive Loop-Back Deactivation Interrupt Enable -Code 0:
This READ/WRITE bit-field is used to either enable or disable the Change of Receive Loop-Back Deactivation State
Interrupt associated with Code 0. If the user enables the Change of Receive Loop-Back Deactivation State Interrupt,
then the Receive DS1 Framer block will generate the Change of Receive Loop-Back Deactivation State Interrupt in
response to the following events.
•
Whenever it detects and validates the Receive Loop-Back Deactivation Pattern (associated with Code 0)
within the incoming DS1 data-stream, and
•
Whenever it ceases to detect the Receive Loop-Back Deactivation Pattern (associated with Code 0) within
the incoming DS1 data-stream.
` 0 = Disables the Change of Receive Loop-Back Deactivation State Interrupt for Code 0.
` 1 = Enables the Change of Receive Loop-Back Deactivation State Interrupt for Code 0
page 710 of word
TABLE 428: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER CODE 1 (ADDRESS = 0XNB14, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Receive
Loop-Back
Activation
Status Code 1
Receive
Loop-Back
Deactivation
Status Code 1
Change of
Receive
Loop-Back
Activation
State Interrupt Status Code 1
Change of
Receive
Loop-Back
Deactivation
State Interrupt Status Code 1
R/O
R/O
R/O
R/O
R/O
R/O
RUR
RUR
0
0
0
0
0
0
0
0
Bits 7 through 4 - Unused:
Bit 3 - Receive Loop-Back Activation Status - Code 1:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging)
the Loop-Up (or Loop-Back Activate) code (associated with Code 1) within the incoming DS1 data-stream, as depicted
below.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Activate"
Code (associated with "Code 1") within the incoming DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Activate" Code
(associated with "Code 1") within the incoming DS1 data-stream.
NOTE: The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document.
This particular register applies to "Code 1".
290
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Bit 2 - Receive Loop-Back Deactivation Status - Code 1:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging)
the Loop-Down (or Loop-Back Deactivate) code (associated with Code 1) within the incoming DS1 data-stream, as
depicted below.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Deactivate"
Code (associated with "Code 1") within the incoming DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Deactivate"
Code (associated with "Code 1") within the incoming DS1 data-stream.
Bit 1 - Change of Receive Loop-Back Activation State Interrupt Status - Code 1:
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change
of Receive Loop-Back Activation State" Interrupt (based upon loop-code "Code 1"), since the last read of this register.
The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State" Interrupt in response
to either of the following events.
• Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Activate" Code (associated with
"Code 1") within the incoming DS1 data-stream
• Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Activate" code (associated with "Code
1") within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Activation
State" Interrupt for "Code 1" since the last read of this register.
` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Activation State"
Interrupt for "Code 1" since the last read of this register.
Bit 0 - Change of Receive Loop-Back Deactivation Status Interrupt Status - Code 1:
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change
of Receive Loop-Back Deactivation State" Interrupt (based upon loop-code "Code 1"), since the last read of this register.
The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in
response to either of the following events.
• Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Deactivate" Code (associated with
"Code 1") within the incoming DS1 data-stream
• Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Deactivate" code (associated with "Code
1") within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Deactivation
State" Interrupt for "Code 1" since the last read of this register.
` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Deactivation
State" Interrupt for "Code 1" since the last read of this register.
TABLE 429: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE
1 (ADDRESS = 0XNB15, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
Change of
Receive
Loop-Back
Activation
Interrupt
Enable Code 1
Change of
Receive
Loop-Back
Deactivation
Interrupt
Enable Code 1
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 through 2 - Reserved:
Bit 1 - Change of Receive Loop-Back Activation Interrupt Enable - Code 1:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Activation
291
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
State" Interrupt associated with Loop-Code "Code 1". If the user enables the "Change of Receive Loop-Back Activation
State" Interrupt, then the Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State"
Interrupt in response to the following events.
• Whenever it detects and validates the "Receive Loop-Back Activation" Pattern (associated with "Code 1") within the
incoming DS1 data-stream, and
• Whenever it ceases to detect the "Receive Loop-Back Activation" Pattern (associated with "Code 1") within the
incoming DS1 data-stream.
` 0 = Disables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 1".
` 1 = Enables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 1".
Bit 0 - Change of Receive Loop-Back Deactivation Interrupt Enable - Code 1:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Deactivation
State" Interrupt. If the user enables the "Change of Receive Loop-Back Deactivation State" Interrupt, then the Receive
DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in response to the
following events.
• Whenever it detects and validates the "Receive Loop-Back Deactivation" Pattern (associated with "Code 1") within
the incoming DS1 data-stream, and
• Whenever it ceases to detect the "Receive Loop-Back Deactivation" Pattern (associated with "Code 1") within the
incoming DS1 data-stream.
` 0 = Disables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 1".
` 1 = Enables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 1".
TABLE 430: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER CODE 2 (ADDRESS = 0XNB1A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Receive
Loop-Back
Activation
Status Code 2
Receive
Loop-Back
Deactivation
Status Code 2
Change of
Receive
Loop-Back
Activation
State Interrupt Status Code 2
Change of
Receive
Loop-Back
Deactivation
State Interrupt Status Code 2
R/O
R/O
R/O
R/O
R/O
R/O
RUR
RUR
0
0
0
0
0
0
0
0
Bits 7 through 4 - Unused:
Bit 3 - Receive Loop-Back Activation Status - Code 2:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging)
the Loop-Up (or Loop-Back Activate) code (associated with Code 2) within the incoming DS1 data-stream, as depicted
below.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Activate"
Code (associated with "Code 2") within the incoming DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Activate" Code
(associated with "Code 2") within the incoming DS1 data-stream.
NOTE: The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in
parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document.
This particular register applies to "Code 2".
Bit 2 - Receive Loop-Back Deactivation Status - Code 2:
This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging)
the Loop-Down (or Loop-Back Deactivate) code (associated with Code 2) within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Deactivate"
292
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Code (associated with "Code 2") within the incoming DS1 data-stream.
` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Deactivate"
Code (associated with "Code 2") within the incoming DS1 data-stream.
Bit 1 - Change of Receive Loop-Back Activation State Interrupt Status - Code 2:
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change
of Receive Loop-Back Activation State" Interrupt (based upon loop-code "Code 2"), since the last read of this register.
The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State" Interrupt in response
to either of the following events.
• Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Activate" Code (associated with
"Code 2") within the incoming DS1 data-stream
• Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Activate" code (associated with "Code
2") within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Activation
State" Interrupt for "Code 2" since the last read of this register.
` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Activation State"
Interrupt for "Code 2" since the last read of this register.
Bit 0 - Change of Receive Loop-Back Deactivation Status Interrupt Status - Code 2:
This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change
of Receive Loop-Back Deactivation State" Interrupt (based upon loop-code "Code 2"), since the last read of this register.
The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in
response to either of the following events.
• Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Deactivate" Code (associated with
"Code 2") within the incoming DS1 data-stream
• Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Deactivate" code (associated with "Code
2") within the incoming DS1 data-stream.
` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Deactivation
State" Interrupt for "Code 2" since the last read of this register.
` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Deactivation
State" Interrupt for "Code 2" since the last read of this register.
TABLE 431: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE
2 (ADDRESS = 0XNB1B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Reserved
BIT 1
BIT 0
Change of
Receive
Loop-Back
Activation
Interrupt
Enable Code 2
Change of
Receive
Loop-Back
Deactivation
Interrupt
Enable Code 2
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 through 2 - Reserved:
Bit 1 - Change of Receive Loop-Back Activation Interrupt Enable - Code 2:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Activation
State" Interrupt associated with Loop-Code "Code 2". If the user enables the "Change of Receive Loop-Back Activation
State" Interrupt, then the Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State"
Interrupt in response to the following events.
• Whenever it detects and validates the "Receive Loop-Back Activation" Pattern (associated with "Code 2") within the
incoming DS1 data-stream, and
293
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
• Whenever it ceases to detect the "Receive Loop-Back Activation" Pattern (associated with "Code 2") within the
incoming DS1 data-stream.
` 0 = Disables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 2".
` 1 = Enables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 2".
Bit 0 - Change of Receive Loop-Back Deactivation Interrupt Enable - Code 2:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Deactivation
State" Interrupt. If the user enables the "Change of Receive Loop-Back Deactivation State" Interrupt, then the Receive
DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in response to the
following events.
• Whenever it detects and validates the "Receive Loop-Back Deactivation" Pattern (associated with "Code 2") within
the incoming DS1 data-stream, and
• Whenever it ceases to detect the "Receive Loop-Back Deactivation" Pattern (associated with "Code 2") within the
incoming DS1 data-stream.
` 0 = Disables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 2".
` 1 = Enables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 2".
2.14
DS1/E1 FRAMER BLOCK REGISTERS - E1 APPLICATIONS
TABLE 432: E1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
Set E1 Mode
Force all
Channels to
Sync to 8kHz
R/O
R/W
R/W
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
1
Unused
BIT 1
BIT 0
Clock Source Select[1:0]
BIT7 - Reserved
BIT6 - Set T1 Mode:
This READ/WRITE bit-field is used to configure the Channel to operate in either the T1 or E1 Mode.
` 0 = Configures the Framer Channel to operate in the E1 Mode
` 1 = Configures the Framer Channel to operate in the T1 Mode
BIT 5 - Force all Channels to Sync to 8kHz:
This READ/WRITE bit-field is used to configure all active (either 21 or 42) Transmit E1 Framer blocks to synchronize
their transmit output frame alignment with the 8kHz signal that is derived from the MCLK PLL.
` 0 = Does not configure each of the Transmit E1 Framer blocks to synchronize their transmit output frame alignment
with the 8kHz signal (from the MCLK PLL).
` 1 = Configures each of the Transmit E1 Framer blocks to synchronize their transmit output frame alignment with the
8kHz signal (from the MCLK PLL).
NOTE: This feature should only be used if the XRT86SH328 has been configured to operate in the 21-Channel E1
Framer/LIU Combo Mode. The user MUST NOT use this feature if the XRT86SH328 has been configured to
operate in any of the Aggregation Modes.
BIT [4:2] - Reserved
BIT [1:0] - Clock Source Select[1:0]:
These two READ/WRITE bit-fields is used to specify the timing source for the Ingress and Direction Transmit E1 Framer
block, within this particular channel.
294
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
The Relationship between the Clock Source Select[1:0] bit-fields and the resulting timing source for
the Transmit E1 Framer block, within this particular Channel
CLOCK SOURCE
SELECT[1:0]
00
TIMING SOURCE FOR TRANSMIT E1 FRAMER BLOCK
Loop-Timing Mode:The Transmit E1 Framer block will derive its timing from the Received
or Recovered Clock signal within the corresponding Receive E1 Framer block
NOTE: This timing option is only available if the user has configured the XRT86SH328 to
operate in the 21-Channel E1 Framer/LIU Combo Mode
01
Local-Timing Mode (TxE1CLK_n Input)The Transmit E1 Framer block will either use upstream timing or the TxE1CLK_n input as its timing source.
NOTE: For Aggregation Applications, the user MUST configure all active T1/E1 Framer
blocks to operate in this timing mode.
10
Local-Timing Mode (MCLK PLL Input)The Transmit E1 Framer block will derive its timing
from the MCLK PLL.NOTE: This timing option is only available if the user has configured
the XRT86SH328 to operate in the 21-Channel E1 Framer/LIU Combo Mode.
11
Loop-Timing ModeThe Transmit E1 Framer block will derive its timing from the Received
or Recovered Clock signal within the corresponding Receive E1 Framer block
NOTE: This timing option is only available if the user has configured the XRT86SH328 to
operate in the 21-Channel E1 Framer/LIU Combo Mode.
TABLE 433: E1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
Transmit
LOS Pattern
Reserved
R/W
R/O
0
1
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Framer
LoopBack[1:0]
Reserved
R/W
R/W
R/O
R/O
R/O
R/O
0
0
0
0
0
0
BIT7 - Transmit LOS Pattern:
This READ/WRITE bit-field configures the Transmit E1 Framer block to generate and transmit the LOS Pattern to the
remote terminal.
` 0 = Configures the Transmit E1 Framer Block to transmit normal E1 traffic
` 1 = Configures the Transmit E1 Framer Block to transmit the LOS pattern.
NOTE: The user MUST set this bit-field to 0 for Normal Operation.
BIT6 - Reserved
BIT [5:4] - Framer Loop-back[1:0]:
These two READ/WRITE bit-fields are used to configure the Transmit/Receive E1 Framer blocks to operate in a variety
of possible loop-back modes, as depicted in the Table below.
Relationship between the Framer Loop-back[1:0] bit-fields and the Corresponding Loop-Back Mode
within the E1 Framer block
FRAMER LOOP-BACK[1:0]
RESULTING LOOP-BACK MODE (WITHIN FRAMER BLOCK)
00
Normal Operation (No Loop-back) Mode
01
Local Loop-back Mode
295
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Relationship between the Framer Loop-back[1:0] bit-fields and the Corresponding Loop-Back Mode
within the E1 Framer block
FRAMER LOOP-BACK[1:0]
RESULTING LOOP-BACK MODE (WITHIN FRAMER BLOCK)
10
Remote Loop-back Mode
11
Reserved
TABLE 434: E1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE
FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Annex B
Tx CRC-4
Error
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
CAS MultiFrame Sel[1:0]
BIT 2
BIT 1
BIT 0
Add Frame
ChkEnable
FAS Frame
Alignment
R/W
R/W
R/W
0
0
0
CRC MultiFrame Sel[1:0]
BIT7 - G.706 Annex B CRC-4 Calculation Enable:
This bit configures the E1 receive framer block to be compliant with ITU-T G.706 Annex B for CRC-to-non-CRC
interworking detection. If Annex B is enabled, G.706 Annex B CRC-4 multi frame alignment algorithm is implemented.
If CRC-4 alignment is enabled and not achieved in 400 msec while the basic frame alignment signal is present, it is
assumed that the remote end is a non CRC-4 equipment. A CRC-to-non-CRC interworking interrupt will be generated.
` 0 = Configures the receive E1 framer block to NOT support the G.706 Annex B CRC-4 multi frame alignment
algorithm.
` 1 = Configures the receive E1 framer block to support the G.706 Annex B CRC-4 multi frame alignment algorithm.
BIT6 - Transmit CRC-4 Error:
This bit is used to force a continuous errored CRC pattern in the outbound CRC multi frame to be sent on the
transmission line. The transmit E1 framer block will implement this error by inverting the value of CRC bit (C1).
` 0 = Disabled
` 1 = Forces the transmit E1 framer block to transmit continuous errored CRC bit.
BIT [5:4] - CAS Multi Frame Select[1:0]:
These bits allow the user to select which CAS multi frame alignment declaration algorithm the receive E1 framer block
will employ, according to the table below.
E1 Framer Block - Framing Select Register (Address = 0xN107, where N ranges in value from 0x01 to
0x38)
CAS MF ALIGN SEL[1:0]
00, 11
CAS MULTI FRAME ALIGNMENT DECLARATION ALGORITHM SELECTED
CAS multi frame alignment disabled.
01
The 16-Frame AlgorithmIf this alignment algorithm is selected, then the receive E1
framer block will monitor the 16th timeslot of each incoming E1 frame and will
declare CAS multi frame alignment (e.g., clear the loss of CAS multi frame defect)
condition anytime that it detects 15 consecutive E1 frames in which bits 1-4 (of time
slot 16) do not contain the CAS Multi Frame Alignment pattern, which is immediately followed by an E1 frame that DOES contain the CAS Multi Frame Alignment
pattern.
10
The 2-Frame (ITU-T G.732) AlgorithmIf this alignment algorithm is selected, then
the receive E1 framer block will declare CAS multi frame alignment anytime it
detects a single E1 frame rather than 15 consecutive E1 frames as described above
in the 16-Frame Algorithm.
296
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: For information on the criteria that the receive E1 framer block uses in order to declare the Loss of CAS Multi
Frame defect condition, please see the register description for the Framing Control Register 0xN10Bh.
BIT [3:2] - CRC Multi Frame Alignment Declaration Criteria Select[1:0]:
These bits allow the user to select which CRC Multi Frame Alignment declaration criteria the receive E1 framer block
will employ. The receive E1 framer block will check for CRC Multi Frame Alignmnet by checking the incoming E1 data
stream and determining whether the international bits (bit 1 of time slot 0) of non-FAS frames match the CRC multi frame
alignment pattern (0,0,1,0,1,1,E1,E2).
CAS MF Align Sel
CAS MF ALIGN SEL[1:0]
CAS MULTI FRAME ALIGNMENT DECLARATION ALGORITHM CRITERIA
00
CRC Multi Frame Alignment Disabled.
01
CRC Multi Frame Alignment is enabled. Alignment is declared if at least 1 valid CRC
multi frame alignment signal is observed within 8 msec.
10
CRC Multi Frame Alignment is enabled. Alignment is declared if at least 2 valid CRC
multi frame alignment signals are observed within 8 msec.
11
CRC Multi Frame Alignment is enabled. Alignment is declared if at least 3 valid CRC
multi frame alignment signals are observed within 8 msec.
NOTE: For information on the criteria that the receive E1 framer block uses to declare the Loss of CRC Multi Frame
Alignment defect condition, please see the register description for the Framing Control Register 0xN10Bh.
BIT 1 - Additional Frame Check Enable - FAS Frame Alignment Declaration:
This bit is used to configure the receive E1 framer block to perform some additional FAS frame synchronization checking
prior to declaration FAS frame alignment. If the user implements this feature, then the receive E1 framer block will
perform some more testing on two additional E1 frames, prior to declaring the FAS frame Alignment condition.
` 0 = Disabled.
` 1 = Enables additional FAS frame checking.
BIT 0 - FAS Alignment Declaration Algorithm Select:
This bit specifies which algorithm the receive E1 framer block uses in its search for the FAS alignment.
` 0 = FAS Alignment Algorithm 1
` 1 = FAS Alignment Algorithm 2
FAS Alignment Algorithm 1 Desciption
a.
Step 1: The receive E1 Framer block begins by searching for the correct 7-bit FAS pattern. Go to step 2 if
found.
b.
Step 2: Check if the FAS is absent in the following frame by verifying that bit 2 of the assumed time slot 0 of
the Non-FAS frame is a one. Go back to step 1 if failed, otherwise go to step 3.
c.
Step 3: check if the FAS is present in the assumed time slot 0 of the third frame. Go back to step 1 if failed.
After the first three steps (if all passed), the receive E1 framer block will declare FAS in Sync if Frame Check Sequence
(BIT 1 of this register) is disabled. If frame check sequence is enabled, then the receive E1 framer block will need to
verify the correct frame alignment.
FAS Alignment Algorithm 2 Description
Algorithm 2 is similar to algorithm 1 but adds a one-frame hold off time after the second step fails. After the second step
fails, it waits for the next assumed FAS in the next frame before it begins the new search for the correct FAS pattern.
297
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 435: E1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
TransmitAUXP Pattern
LOF DeclarationCriteria
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Transmit YEL and Multi
YEL[1:0]
BIT 2
Transmit AIS Pattern
Select[1:0]
BIT 1
BIT 0
AIS Defect Declaration Criteria[1:0]
BIT7 - Transmit Auxiliary Pattern:
This bit is used to transmit an auxiliary pattern (repeating …010101) to the transmit line interface.
` 0 = Disabled
` 1 = Enable AUXP Pattern
BIT6 - Loss of Frame Declaration Criteria
This bit is used to select Loss of Frame Declaration Criteria for the receive E1 framer block.
` 0 = Loss of frame is declared immediately if either CRC multi frame alignment or FAS alignment is lost.
` 1 = Loss of frame is declared immediately if FAS alignment is lost. If CRC multi frame alignment is lost for more than
8 msec, the E1 receive framer will force a frame search.
BIT [5:4] - Yellow Alarm and Multi Yellow Alarm Generation [1:0]:
These bits activate or deactivate the transmission of yellow and multi frame yellow alarm. The yellow alarm and multi
frame yellow alarm can be forced to transmit as 1, or be inserted upon detection of loss of alignment.
YEL and Multi YE
YEL AND MULTI YEL[1:0]
00 / 10
YELLOW ALARM TRANSMITTED
Disabled.
01
Automatic Transmission of YEL and CAS Multi YELWhenever the receive E1
framer block declares LOF or Loss CAS Multi Frame Alignment, the corresponding
transmit E1 framer block will automatically transmit the Yellow Alarm indicator by
setting BIT 3 of time slot 0 within the non-FAS frames to 1.
11
Force Transmission of YEL and CAS Multi YELBoth Yellow and Multi Frame Yellow Alarm are transmitted as '1'
BIT [3:2] - Transmit AIS Pattern Select[1:0]
These two READ/WRITE bit-fields are used to select the type of AIS Pattern that the Transmit E1 Framer block will send
if enabled.
The Relationship between Transmit AIS Pattern Select[1:0] and the resulting behavior of the Transmit
E1 Framer block
TRANSMIT AIS PATTERN
SELECT[1:0]
TRANSMIT E1 FRAMER BLOCK ACTION
00
Transmits Normal TrafficTransmit E1 Framer block does not transmit the AIS indicator.
It will (instead) transmit normal traffic
01
Unframed All Ones PatternThe Transmit E1 Framer block will transmit an Unframed
All Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [0,
1].
298
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
The Relationship between Transmit AIS Pattern Select[1:0] and the resulting behavior of the Transmit
E1 Framer block
TRANSMIT AIS PATTERN
SELECT[1:0]
TRANSMIT E1 FRAMER BLOCK ACTION
10
The AIS-16 PatternIn this case, time slot 16 in each frame will be set to an All Ones
Pattern.
11
Framed All Ones PatternThe Transmit E1 Framer block will transmit a Framed All
Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [1, 0].
BIT[1:0] - AIS Defect Declaration Criteria[1:0]
These two READ/WRITE bit-fields are used to select the type of AIS Pattern that the Receive E1 Framer block will look
for in order to determine whether or not it should declare or clear the AIS defect condition.
The Relationship between AIS Defect Declaration Criteria[1:0] and the resulting AIS Pattern that the
Receive E1 Framer block will look for in declaring/clearing the AIS defect condition
AIS DEFECT DECLARATION
CRITERIA[1:0]
RECEIVE E1 FRAMER BLOCK - AIS DEFECT DECLARATION CRITERIA
00
AIS Defect Declaration is DisabledThe Receive E1 Framer block will NOT declare
the AIS defect condition at all.
01
Unframed and Framed All Ones Pattern:The Receive E1 Framer block will
declare the AIS defect condition whenever it receives either the Framed or
Unframed All Ones pattern for at least 42ms.
10
AIS-16 All Ones Pattern:The Receive E1 Framer block will declare the AIS defect
condition whenever it receives all ones in the 16th time slot.
11
Framed All Ones Pattern:The Receive E1 Framer block will only declare the AIS
defect condition whenever it receives the Framed All Ones Pattern for at least
42ms.
TABLE 436: E1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN
VALUE FROM 0X01 TO 0X38)
BIT7
BIT6
BIT 5
E-Bit SourceSelect
BIT 4
BIT 3
Reserved
BIT 2
Data Link SourceSelect
BIT 1
BIT 0
CRC-4
Source
Select
Framing
Alignment
Pattern
Select
R/O
R/W
R/W
R/W
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT [7:6] - E-Bit Source Select
• These bits are used to specify the source of E-bits wihin each outbound E1 frame.
E-bits
E-BITS [1:0]
00
E-BIT SOURCE SELECT
Internal Framer BlockThe E-bits are used to indicate whether the receive E1 framer
block has detected a CRC error within the most recently received sub-multi frame.
The receive E1 framer will indicate a received errored sub-multi frame by setting the
binary state of the E-bits from 1 to 0 for each errored sub-multi frame.
299
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
E-bits
E-BITS [1:0]
E-BIT SOURCE SELECT
01
All E-bits within the outbound E1 data stream are set to 0.
10
All E-bits within the outbound E1 data stream are set to 1.
11
The E-bits are used to carry the data link information.
BIT [5:4] - Reserved
BIT [3:2] - Data Link Source Select
These bits are used to specify the source of the data link bits that will be inserted in the outbound E1 frames.
YEL and Multi YEL
YEL AND MULTI YEL[1:0]
YELLOW ALARM TRANSMITTED
00 / 11
The transmit serial input from the transmit payload data input block will be the source
for the data link bits.
01
The Transmit HDLC Controller will generate either BOS (bit oriented signaling) or
MOS (message oriented signaling) messages which will be inserted into the data link
bits in the outbound E1 frames.
10
Reserved.
BIT 1 - CRC-4 Source Select
BIT 0 - Framing Alignment Pattern Select
2.15
CHANNEL CONTROL-VT MAPPER BLOCK REGISTERS
The register map for the Channel Control VT-Mapper Block registers is presented in the Table below.
Additionally, a detailed description of each of the Channel Control VT-Mapper Block registers is presented
below.
In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the
XRT86SH328, with both the VT/TU Mapper and VT/TU De-Mapper Blocks highlighted is presented below in
Figure 19.
300
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
FIGURE 19. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE VTMAPPER BLOCK HIGHLIGHTED
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
To DS1/E1 Channels 1 - 3
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
TABLE 437: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION DS1/E1 INSERTION CONTROL
REGISTER - 2 (ADDRESS = 0XND41)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Transmit RDI-V Source[1:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
BIT[7:2] - Unused:
BIT[1:0] - Transmit RDI-V Type[1:0]:
This READ/WRITE bit-field is used to specify the source of Bits 5, 6 and 7 (within the K4 VT-POH byte), whenever the
Transmit VT-Mapper Block is configured to support the transmission of the Extended RDI-V indicators.
Transmit RDI-V Source
TRANSMIT RDI-V
SOURCE[1:0]
RESULTING SOURCE OF BITS 5, 6 AND 7 OF K4 BYTE
00
Receive Status per the corresponding Receive VT-Mapper Block
01
From On-Chip Register
301
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Transmit RDI-V Source
TRANSMIT RDI-V
SOURCE[1:0]
RESULTING SOURCE OF BITS 5, 6 AND 7 OF K4 BYTE
10
Do Not Use
11
Receive Status per the corresponding Receive VT-Mapper Block
TABLE 438: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL
REGISTER - 1 (ADDRESS = 0XND42, WHERE N RANGES FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
Ingress
Direction
DS1/E1 AIS
Defect
Declared
Unused
BIP-2 Error
Insert
R/O
R/O
R/W
R/W
R/W
0
0
0
0
0
BIT 2
BIT 1
BIT 0
Auto
Transmit
RFI-V
Indicator
Auto
Transmit
RDI-V
Indicator
R/W
R/W
R/W
0
0
0
VT Signal Label[2:0]
BIT 7 - Receive (Ingress Direction) DS1/E1 AIS Defect Declared:
This READ/WRITE bit-field indicates whether or not the corresponding DS1 or E1 signal (that is being handled by this
Transmit VT-Mapper block) is transporting the AIS indicator.
` 0 - Indicates that the Ingress Direction DS1 or E1 signal is NOT currently transporting the AIS indicator.
` 1 - Indicates that the Ingress Direction DS1 or E1 signal is currently transporting the AIS indicator.
BIT 6 - Unused
BIT 5 - BIP-2 Error Insert
This READ/WRITE bit-field is used to configure the corresponding VT-Mapper block to transmit VTs with erred BIP-2
bits into the "Ingress Direction VT-data-stream (towards the Transmit STS-1/STS-3 POH Processor block). If the user
opts to invoke this feature, then the VT-Mapper block will automatically invert the value of the "locally-computed" BIP-2
bits (within each outbound VT), prior to transmitting this data to the Transmit STS-1/STS-3 POH Processor block.
` 0 - Configures the Transmit VT-Mapper block to NOT transmit VTs with erred BIP-2 bits to downstream circuitry
(normal operation).
` 1 - Configures the Transmit VT-Mapper block to transmit VTs with erred BIP-2 bits to downstream circuitry(normal
operation).
NOTE: For normal operation, the user should set this bit-field to 0.
BIT [4:2] - VT Label[2:0]:
These three (3) READ/WRITE bit-fields are used to set the VT Label bit-fields (within each outbound V5 byte) the value
of the users choice.
BIT 1 - Auto Transmit RFI-V Indicator
This READ/WRITE bit-field is used to select the source of the RFI-V bit-field, within the V5 byte of the outbound
VT1.5/VT2 traffic. In this case, the user has the following two options.
a.
The user can configure the VT-Mapper block to use an on-chip register as the source of the RFI-V bit-fields
(within the V5 byte). More specifically, the VT-Mapper block will read out the contents within Bit 7 (Transmit
RFI-V Value) within the "VT-Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register (Address =
0xND43)" and it will load this value into RFI-V bit-field position within each outbound VT. In this case, the user
will have Software Control over the state of the RFI-V bit-field, within the V5 byte of the outbound VT traffic) or
b.
The Transmit VT-Mapper block will set the RFI-V bit-fields to the appropriate value, based upon any defect
conditions that are currently being declared by the corresponding VT-De-Mapper block.
` 0 - Configures the Transmit VT-Mapper Block to use the on-chip register as the source of the RFI-V bit-field.
302
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 1 - Configures the Transmit VT-Mapper block to set the RFI-V bit-fields to the appropriate value, based upon any
defects that the corresponding Receive VT-Mapper block is currently declaring.
BIT 0 - Auto Transmit RDI-V Indicator
This READ/WRITE bit-field is used to select the source of the RDI-V bit-field, within the V5 byte of each outbound
VT1.5/VT2 traffic. In this case, the user has the following two options.
a.
The user can configure the Transmit VT-Mapper block to use an on-chip register as the source of the RDI-V
bit-fields (within the V5 byte). More specifically, the Transmit VT-Mapper block will read out the contents
within BIT6 (Transmit RDI-V value) within the VT Mapper Block - Ingress Direction - DS1/E1 Insertion Control
Register (Address = 0xND43) and it will load this value into the RDI-V bit-field position within each outbound
VT. In this case, the user will have Software Control over the state of the RDI-V bit-fields, within the outbound
VT traffic) or
b.
The Transmit VT-Mapper block will set the RDI-V bit-fields to the appropriate value, based upon any defect
conditions that are currently being declared by the corresponding VT-De-Mapper block.
` 0 - Configures the Transmit VT-Mapper Block to use the on-chip register as the source of the RDI-V bit-field.
` 1 - Configures the Transmit VT-Mapper block to set the RDI-V bit-fields to the appropriate value, based upon any
defects that the corresponding VT-De-Mapper block is currently declaring.
TABLE 439: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL
REGISTER - 0 (ADDRESS = 0XND43 , WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit
RFI-V Value
Transmit
RDI-V Value
Transmit AIS-V
Indicator
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
DS1/E1 Cross Connect Channel Select_Ingress Direction[4:0]
BIT7 - Transmit RFI-V Value:
This READ/WRITE bit-field is used to exercise Software Control over the state of the RFI-V bit-field (within each V5
byte) of the outbound VT data-stream. If the user sets BIT 1 (Auto Transmit RFI-V Indicator), within the VT-Mapper
Block - Ingress Direction - DS1/E1 Insertion Control Register - 2 to 0, then the Transmit VT-Mapper block will read out
the contents within this bit-field, and it will load this value into the RFI-V bit-field within each V5 byte of the outbound VTdata-stream.
NOTE: This bit-field is ignored if the user sets Bit 1 (Auto Transmit RFI-V Indicator), within the VT Mapper Block Ingress Direction - DS1/E1 Insertion Control Register - 1 to 1.
BIT6 - Transmit RDI-V Value:
This READ/WRITE bit-field is used to exercise Software Control over the state of the RDI-V bit-field (within each V5
byte) of the outbound VT data-stream. If the user sets BIT 0 (Auto Transmit RDI-V Indicator), within the VT-Mapper
Block - Ingress Direction - DS1/E1 Insertion Control Register - 2 to 0, then the Transmit VT-Mapper block will read out
the contents within this bit-field, and it will load this value into the RDI-V bit-field within each V5 byte of the outbound
VT-data-stream.
NOTE: This bit-field is ignored if the user sets Bit 0 (Auto Transmit RDI-V Indicator), within the VT Mapper Block Ingress Direction - DS1/E1 Insertion Control Register - 1 to 1.
BIT 5 - Transmit AIS-V Indicator
This READ/WRITE bit-field is used to command the Transmit VT-Mappper block to transmit the AIS-V indicator (within
the corresponding VT1.5 or VT2) within the outbound VT-data-stream.
0 - Configures the Transmit VT-Mapper block to NOT transmit the AIS-V indicator within the outbound VT-data-stream.
1 - Configures the Transmit VT-Mapper block to transmit the AIS-V indicator within the outbound VT-data-stream as
shown in Figure 20.
303
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
FIGURE 20. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WHENEVER THE VTMAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) HAS BEEN CONFIGURED TO TRANSMIT THE AIS-V INDICATOR
TOWARDS DOWN-STREAM CIRCUITRY
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
AIS-V
Indicator
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
BIT[4:0] - DS1/E1 (Cross-Connect) Channel Select[4:0]:
These READ/WRITE bit-fields is used to configure the Internal VT-Cross Connect. More specifically, these
READ/WRITE bit-fields are used to select which (of the 28 Ingress Direction) T1/E1 signals to be mapped into either a
VT1.5 or VT2 by this particular Transmit VT-Mapper block. The following table presents the relationship between the
settings of these bit-fields and the resulting Cross Connect Configuration.
Cross Connect Configuration
DS1/E1 (CROSSCONNECT) CHANNEL
SELECT[4:0]
RESULTING INGRESS DIRECTION T1/E1
CHANNEL BEING HANDLED BY THIS
PARTICULAR TRANSMIT VT-MAPPER BLOCK
00000
NONE
00001
Ingress Direction T1/E1 Channel 1
00010
Ingress Direction T1/E1 Channel 2
00011
Ingress Direction T1/E1 Channel 3
00100
Ingress Direction T1/E1 Channel 4
00101
Ingress Direction T1/E1 Channel 5
COMMENTS
This particular VT will be transmitted as an
Un-equipped signal
304
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Cross Connect Configuration
DS1/E1 (CROSSCONNECT) CHANNEL
SELECT[4:0]
RESULTING INGRESS DIRECTION T1/E1
CHANNEL BEING HANDLED BY THIS
PARTICULAR TRANSMIT VT-MAPPER BLOCK
00110
Ingress Direction T1/E1 Channel 6
00111
Ingress Direction T1/E1 Channel 7
01000
Ingress Direction T1/E1 Channel 8
01001
Ingress Direction T1/E1 Channel 9
01010
Ingress Direction T1/E1 Channel 10
01011
Ingress Direction T1/E1 Channel 11
01100
Ingress Direction T1/E1 Channel 12
01101
Ingress Direction T1/E1 Channel 13
01110
Ingress Direction T1/E1 Channel 14
01111
Ingress Direction T1/E1 Channel 15
10000
Ingress Direction T1/E1 Channel 16
10001
Ingress Direction T1/E1 Channel 17
10010
Ingress Direction T1/E1 Channel 18
10011
Ingress Direction T1/E1 Channel 19
10100
Ingress Direction T1/E1 Channel 20
10101
Ingress Direction T1/E1 Channel 21
10110
Ingress Direction T1/E1 Channel 22
10111
Ingress Direction T1/E1 Channel 23
11000
Ingress Direction T1/E1 Channel 24
11001
Ingress Direction T1/E1 Channel 25
11010
Ingress Direction T1/E1 Channel 26
11011
Ingress Direction T1/E1 Channel 27
11100
Ingress Direction T1/E1 Channel 28
11101
NONE
11110
The Test Channel
11111
Test Pattern - From VT Pattern Generator
305
COMMENTS
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 440: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL
REGISTER - BYTE 3 (ADDRESS = 0XND44, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
RDI-V Accepted Value[3:0]
BIT 2
BIT 1
BIT 0
RDI-V Accept Threshold[3:0]
R/O
R/O
R/O
R/O
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
BIT[7:4] - RDI-V Accepted Value[3:0]:
These READ-ONLY bit-fields reflect the most recently value for RDI-V that has been accepted (or validated) by the
VTDe--Mapper Block. The VT-De--Mapper block will accept (or validate) a given RDI-V value, once it has received this
same RDI-V value, within RDI-V_Accept_Threshold[3:0] number of consecutive, incoming VT Multi-frames.
NOTES:
1. These bit-fields are only active if the user has configured the Receive VT-De-Mapper block to support
ERDI-V (Enhanced RDI-V).
2. These bit-fields reflect the four-bit RDI-V value that the VT De-Mapper block has accepted via the K4
bytes within the incoming VT/TU data-stream.
BIT[3:0] - RDI-V Accept Threshold[3:0]:
These READ/WRITE bit-fields are used to define the RDI-V Validation criteria for the VT-De-Mapper block. More
specifically, these bit-fields are used to specify the number of consecutive, incoming VT Multi-frame, in which the VTDe-Mapper block MUST receive a given RDI-V value BEFORE it validates it and loads it into BIT[7:4] (RDI-V Accepted
Value[3:0]).
TABLE 441: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL
REGISTER - BYTE 2 (ADDRESS = 0XND45, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
BIT 0
RDI-V Type
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/W
0
0
0
0
0
0
0
0
BIT[7:1] - Unused:
BIT 0 - RDI-V Type:
This READ/WRITE bit-field is used to configure the VT-De-Mapper blocks (associated with a given channel) to support
either the SRDI-V (Single Bit - RDI-V) or ERDI-V (Extended - RDI-V) form of signaling. If the user uses only Single-Bit
RDI-V, then the RDI-V indicator will only be transported via Bit 8 (RDI-V) within the V5 byte in a VT-data-stream.
Conversely, if a user uses Extended RDI-V, then the RDI-V indicator will be transported via both Bits 8 (RDI-V) within
the V5 byte, and Bits 5, 6 and 7 within the Z7/K4 byte.
` 0 - Configures the VT-De-Mapper blocks to use the SRDI-V form of Signaling.
` 1 - Configures the VT-De-Mapper blocks to use the ERDI-V form of signaling.
NOTE: This configuration setting only applies to the VT-De-Mapper block. If the user wishes to configure the VT-Mapper
block to support either the "SRDI-V" or the "ERDI-V" form of signaling, then he/she must set Bit 1 (RDI-V Type)
within the "Channel Control - VT-Mapper Block - Ingress Direction - Transmit RDI-V Control Register - Byte 0" to
the appropriate state.
306
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 442: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL
REGISTER - BYTE 1 (ADDRESS = 0XND46, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
VT Size
Error
Defect
Declared
LOP-V
Defect
Declared
Change in
VT Label
Value[2:0]
Indicator
R/O
R/O
R/O
R/W1C
R/O
R/O
R/O
R/O
0
0
1
0
0
0
0
0
VT Label Value[2:0]
BIT 0
AIS-V Defect
Declared
BIT7 -Unused:
BIT6 - VT Size ErroDefect Declared:
This READ-ONLY bit-field indicates whether or not the Receive VT-De-Mapper block is currently declaring the VT Size
Error defect condition. The Receive VT-De-Mapper block will declare the VT Size Error defect condition anytime it
receives a VT data-stream with V1 bytes that contains the incorrect VT-Size bit values, as depicted below.
` 0 - Indicates that the Receive VT-De-Mapper block is NOT currently declaring the VT Size Error Defect condition.
` 1 - Indicates that the Receive VT-De-Mapper block is currently declaring the VT Size Error Defect condition.
BIT 5 - LOP-V Defect Declared:
This READ-ONLY bit-field indicates whether or not the Receive VT-Mapper block is currently declaring the LOP-V
Defect condition.
` 0 - Indicates that the Receive VT-De-Mapper Block is currently NOT declaring the LOP-V Defect Condition.
` 1 - Indicates that the Receive VT-De-Mapper block is currently declaring the LOP-V Defect Condition
BIT 4 - Change in VT Label[2:0] Indicator:
This READ/WRITE 1 to CLEAR bit-field indicates whether or not the Receive VT-De-Mapper block has detected a
Change in VT Signal Label, since the last time the user read and cleared this register bit
0 - Indicates that the Receive VT-De-Mapper block has NOT detected a Change in VT Signal Label since the last time
the user read and cleared this register bit.
BIT[3:1] - VT Label Value[2:0]:
This READ-ONLY bit-field reflects the value of the most recently accepted (or validated) VT Signal Label value.
BIT 0 - AIS-V Defect Declared:
This READ-ONLY bit-field indicates whether or not the Receive VT-De- Mapper block is currently declaring the AIS-V
defect condition.
` 0 - Indicates that the Receive VT-De-Mapper Block is NOT currently declaring the AIS-V defect condition.
` 1 - Indicates that the Receive VT-De-Mapper Block is currently declaring the AIS-V defect condition.
TABLE 443: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL
REGISTER - BYT E 0 (ADDRESS = 0XND47, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
RFI-V Defect
Declared
RDI-V Defect
Declared
Force
DS1/E1 AIS
In Egress
Direction
R/O
R/O
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
DS1/E1 Cross Connect Channel Select_Egress Direction[4:0]
307
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
BIT7 - RFI-V Defect Declared:
This READ/WRITE bit-field indicates whether or not the Receive VT-De-Mapper Block is currently declaring the RFI-V
defect condition.
` 0 - Indicates that the Receive VT-De-Mapper Block is NOT currently declaring the RFI-V defect condition.
` 1 - Indicates that the Receive VT-De-Mapper Block is currently declaring the RFI-V defect condition.
BIT6 - RDI-V Defect Declared:
This READ/WRITE bit-field indicates whether or not the Receive VT-De-Mapper Block is currently declaring the RDI-V
defect condition.
` 0 - Indicates that the Receive VT-De-Mapper Block is NOT currently declaring the RDI-V defect condition.
` 1 - Indicates that the Receive VT-De-Mapper Block is currently declaring the RDI-V defect condition.
BIT 5 - Force DS1/E1 AIS In Egress Direction
This READ/WRITE bit-field is used to configure this particular Receive VT-De-Mapper block to transmit the DS1/E1 AIS
indicator within the Egress Direction of this particular DS1/E1 Channel.
` 0 - Configures the Receive VT-De-Mapper Block to NOT transmit the DS1/E1 AIS Pattern within the Egress Direction
corresponding to this particular channel.
` 1 - Configures the Receive VT-De-Mapper block to transmit the DS1/E1 AIS Pattern within the Egress Direction
corresponding to this particular channel.
Figure 21 presents an illustration of the Functional Block Diagram of the XRT86SH328, whenever the VT-De-Mapper
block has been configured to overwrite the contents within the corresponding DS1/E1 channel with the DS1/E1 AIS
pattern (as it is being de-mapped from the VT1.5 or VT2 data-stream by the VT De-Mapper block.
FIGURE 21. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE VTDE-MAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) OVERWRITES THE CONTENTS OF A DE-MAPPED DS1/E1
SIGNAL WITH THE DS1/E1 AIS PATTERN
STS-1/
STS-1/
STS-3
STS-3
Telecom
Telecom
Bus
Bus
Interface
Interface
Transmit
Transmit
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Transmit
Transmit
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
VT/TU
VT/TU
Mapper
Mapper
Block
Block
Ingress
Direction
Transmit
DS1/E1
Framer
Block
Ingress
Direction
Receive
DS1/E1
Framer
Block
Receive
DS1/E1
LIU
Block
DS1/E1 Channel 0
From DS1/E1 Channels 1 - 27
From DS2 Channels 1 - 6
Transmit
Transmit
DS3
DS3
Framer
Framer
Block
Block
DS3/
DS3/
STS-1
STS-1
LIU
LIU
Interface
Interface
M23
M23
MUX
MUX
Block
Block
M12
MUX
Block
From DS1/E1 Channels 1 - 3
DS2 Channel 0
Receive
Receive
DS3
DS3
Framer
Framer
Block
Block
M23
M23
De-MUX
De-MUX
Block
Block
M12
De-MUX
Block
DS2 Channel 0
To DS1/E1
Channels 1 - 27
Receive
Receive
STS-1/3
STS-1/3
TOH
TOH
Processor
Processor
Block
Block
Receive
Receive
STS-1
STS-1POH
POH
Processor
Processor
Block
Block
To DS1/E1 Channels 1 - 3
To DS2 Channels 1 - 6
VT/TU
De-Mapper
Block
DS1/E1 AIS
308
DS1/E1
Jitter
Atten
Block
Egress
Direction
Receive
DS1/E1
Framer
Block
Egress
Direction
Transmit
DS1/E1
Framer
Block
Transmit
DS1/E1
LIU
Block
DS1/E1 Channel 0
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
BIT[4:0] - DS1/E1 Cross Connect Channel Select_Egress Direction[4:0]:
These READ/WRITE bit-fields are used to configure the Internal VT-Cross Connect.
More specifically, these READ/WRITE bit-fields are used to select which (of the 28 Egress Direction) T1/E1 Ports, that
this particular Receive VT-Mapper block will route (or direct) its Egress Direction T1/E1 Signal to.
The following table presents the relationship between the settings of these bit-fields and the resulting Cross-Connect
Configuration.
Cross Connect Configuration
DS1/E1 (CROSS CONNECT)
CHANNEL SELECT[4:0]
RESULTING PORT THAT THIS RECEIVE VT-MAPPER BLOCK
WILL DIRECT ITS T1/E1 TRAFFIC TO
00000
No Clock or Data is output via Corresponding Egress
Direction T1/E1 Port
00001
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 1
00010
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 2
00011
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 3
00100
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 4
00101
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 5
00110
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 6
00111
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 7
01000
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 8
01001
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 9
01010
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 10
01011
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 11
01100
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 12
01101
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 13
01110
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 14
01111
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 15
10000
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 16
309
COMMENTS
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
Cross Connect Configuration
DS1/E1 (CROSS CONNECT)
CHANNEL SELECT[4:0]
RESULTING PORT THAT THIS RECEIVE VT-MAPPER BLOCK
WILL DIRECT ITS T1/E1 TRAFFIC TO
10001
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 17
10010
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 18
10011
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 19
10100
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 20
10101
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 21
10110
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 22
10111
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 23
11000
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 24
11001
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 25
11010
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 26
11011
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 27
11100
Egress Direction T1/E1 Signal is routed to the Egress
Direction Output of T1/E1 Channel 28
COMMENTS
11101
11110
11111
TABLE 444: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER BYTE 1 (ADDRESS = 0XND4A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
VT Payload Pointer Increment Count[3:0]
BIT 2
BIT 1
BIT 0
BIP-2 Error Count[11:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT 7 - 4 - VT Payload Pointer Increment Count[3:0]:
These RESET-upon-READ bit-fields reflect the number of VT Payload Pointer Increment events that the Receive VTDe-Mapper block has detected since the last read of this register. The Receive VT-Mapper block will increment the
contents within these bit-fields each time that it detects a VT Payload Pointer Increment event within the incoming VT
data-stream.
310
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT
Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields.
BIT[3:0] - BIP-2 Error Count[11:8]:
These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - BIP-2 Error
Count Register - Byte 0, presents a 12-bit expression that reflects the number of BIP-2 Errors that the Receive VTMapper Block has detected (within the incoming VT-data-stream) since the last read of this register.
These particular bit-fields are the four most significant bit-fields within this 12-bit expression.
NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT DeMapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields
TABLE 445: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER BYTE 0 (ADDRESS = 0XND4B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
BIP-2 Error Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:0] - BIP-2 Error Count[7:0]:
These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - BIP-2 Error
Count Register - Byte 1, presents a 12-bit expression that reflects the number of BIP-2 Errors that the Receive VT-DeMapper Block has detected (within the incoming VT-data-stream) since the last read of this register.
These particular bit-fields are the eight least significant bit-fields within this 12-bit expression.
NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT
Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields.
TABLE 446: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER BYTE 1 (ADDRESS = 0XND4E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
VT-Payload Pointer Decrement Count[3:0]
BIT 2
BIT 1
BIT 0
REI-V Event Count[11:8]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT [7:4] - VT Payload Pointer Decrement Count[3:0]:
These RESET-upon-READ bit-fields reflect the number of VT Payload Pointer Decrement events that the Receive VTDe-Mapper block has detected since the last read of this register. The Receive VT-Mapper block will increment the
contents within these bit-fields each time that it detects a VT Payload Pointer Decrement event within the incoming VT
data-stream.
NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT
Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields
BIT [3:0] - REI-V Event Count[11:8]:
These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - REI-V Event
Count Register - Byte 0, presents a 12-bit expression that reflects the number of REI-V Events that the Receive VTMapper Block has detected (within the incoming VT-data-stream) since the last read of this register.
These particular bit-fields are the four most significant bit-fields within this 12-bit expression.
NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT
Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields.
311
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 447: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER BYTE 0 (ADDRESS = 0XND4F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT7
BIT6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REI-V Event Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
BIT[7:0] - REI-V Event Count[7:0]:
These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - REI-V Event
Count Register - Byte 1, presents a 12-bit expression that reflects the number of REI-V Events that the Receive VT-DeMapper Block has detected (within the incoming VT-data-stream) since the last read of this register.
These particular bit-fields are the eight least significant bit-fields within this 12-bit expression.
NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT
Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields.
TABLE 448: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - RECEIVE APS REGISTER - BYTE 0
(ADDRESS = 0XND53, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
Receive APS Value[3:0]
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - 4 - Unused:
This READ/WTC bit-field indicates whether or not the Change of Receive APS Value event has occurred (within this
Tributary) since the last time that the user has written a 1 to clear this bit-field. The Receive VT-De-Mapper block will
declare the Change of Receive APS Value whenever it has accepted a new value from the K4 bytes within the incoming
VT data-stream.
` 0 - Indicates that the Change of Receive APS Value event has NOT occurred since the last time the user has written
a 1 to clear this bit-field.
` 1 - Indicates that the Change of Receive APS Value event has occurred since the last time the user has written a 1
to clear this bit-field.
BIT 3 - 0 - Receive APS Value[3:0]:
These four (4) READ-ONLY bit-field reflects the APS value that the VT-De-Mapper block has received (via Bits 1
through 4, within the K4 byte) and has validated.
TABLE 449: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS REGISTER - BYTE 2
(ADDRESS = 0XND56, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
DS1/E1 AIS DS1/E1 LOC
- Event Mask -Event Mask
BIT 4
Reserved
BIT 3
BIT 2
Transmit
Elastic Store
Overflow
BIT 1
BIT 0
Reserved
R/W
R/O
R/O
R/O
RUR
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - Change of DS1/E1 AIS Defect Condition - Event Mask:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of DS1/E1 AIS Defect Condition"
event to/from causing the "Change of DS1/E1 AIS Defect Condition" interrupt to be generated. If the user enables this
312
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
feature, then the VT-Mapper block will assert the "Change of DS1/E1 AIS Defect Condition" interrupt in response to
either of the following conditions.
• Whenever the VT-Mapper block declares the "DS1/E1 AIS" defect condition within the Ingress Direction DS1/E1
Data-stream.
• Whenever the VT-Mapper block clears the "DS1/E1 AIS" defect condition within the Ingress Direction DS1/E1 Data
Stream.
` 0 - Configures the VT-Mapper Block to NOT generate the "Change of DS1/E1 AIS Defect Condition" interrupt,
whenever it declares or clears the DS1/E1 AIS defect condition.
` 1 - Configures the VT-Mapper Block to generate the "Change of DS1/E1 AIS Defect Condition" interrupt, whenever it
declares or clears the "DS1/E1 AIS defect condition.
BIT 6 - 4 Reserved:
BIT 3 - Transmit Elastic Store Overflow:
This RESET-upon-READ bit-field indicates whether or not the VT Mapper block has declared a "Transmit Elastic Store
Overflow" event since the last read of this register. The VT-Mapper Block will declare a "Transmit Elastic Store
Overflow" event anytime that the "Transmit FIFO" (within the VT-Mapper block) has experience an "overflow" event.
` 0 - Indicates that the "Transmit Elastic Store Overflow" event has NOT occurred since the last read of this register.
` 1 - Indicates that the "Transmit Elastic Store Overflow" event has occurred since the last read of this register.
NOTE: The VT-Mapper block will typically handle "small timing offsets" (between the Ingress Direction T1/E1 signal and the
"Transmit Direction" 19.44MHz or 51.84MHz clock signal via bit-stuffing (as it maps this T1/E1 data into VTs.
However, if this bit-field is set to "1", this is typically a indication of a significant clock frequency accuracy problem
within the system.
BIT 0 - Reserved:
TABLE 450: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS/K4 REGISTER
(ADDRESS = 0XND57, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
TxERDI
]
BIT 1
BIT 0
TxAPS[3:0
R/W
R/W
R/W
R/W
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - Unused:
BIT 6 - 4 - Transmit ERDI-V[2:0]
These three (3) READ/WRITE bit-fields permit the user to exercise software control over the value of the "ERDI-V" bits
that are transported via "Bits 5 through 7" (within the K4 byte) within the outbound VT data-stream.
NOTE: This bit-field is only active if both of the following is true.
a.
The user has configured VT-Mapper/De-Mapper blocks to support the ERDI-V (Extended - RDI-V) form of
signaling and,
b.
The user has set Bit 6 (Transmit RDI-V Value) within the "Channel Control - VT Mapper Block - Ingress
Direction - DS1/E1 Insertion Control Register - 0" to "1".
BIT 3 - 0 - Transmit APS Value[3:0]
These four (4) READ/WRITE bit-fields permit the user to exercise software control over the value of the "APS" bits that
are transported via Bits 1 through 4 (within the K4 byte) within the outbound VT data-stream
313
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 451: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - J2 BYTE STATUS REGISTER
(ADDRESS = 0XND63, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
Unused
BIT 2
BIT 1
BIT 0
TIM-V Defect
Declared
VT Path Trace
Message
Unstable Defect
Declared
Unused
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
0
0
0
0
0
0
0
0
BIT 7 - 3 - Unused:
BIT 2 - TIM-V Defect Declared:
This READ-ONLY bit-field indicates whether or not the VT-De-Mapper block is currently declaring the "VT Trace
Identification Mismatch" (TIM-V) defect condition.
The VT-De-Mapper block will declare the TIM-V defect condition, when none of the received 1, 16 or 64-byte string
(received via the J2 byte, within the incoming VT-data-stream) matches the expected 1, 16 or 64 byte message.
The VT-De-Mapper block will clear the "TIM-V" defect condition, when 80% of the received 1, 16 or 64 byte string
(received via the J2 byte) matches the 1, 16 or 64 byte message.
` 0 - Indicates that the VT-De-Mapper block is NOT currently declaring the TIM-V defect condition.
` 1 - Indicates that the VT-De-Mapper block is currently declaring the TIM-V defect condition.
BIT 1 - VT Path Trace Message Unstable Defect Declared:
This READ-ONLY bit-field indicates whether or not the VT-De-Mapper block is currently declaring the "VT Path Trace
Message Unstable" defect condition. The VT-De-Mapper block will declare the "VT Path Trace Message Unstable"
defect condition, whenever the "VT Path Trace Message Unstable" counter reaches the value "8". The VT-De-Mapper
block will increment the "VT Path Trace Message Unstable" counter for each time that it receives a "VT Path Trace
Message" that differs from the previously received message. The "VT Path Trace Message Unstable" counter is cleared
to "0" whenever the VT-De-Mapper block has received a given "VT Path Trace Message" 3 (or 5) consecutive times.
` 0 - Indicates that the VT-De-Mapper block is NOT currently declaring the "VT:Path Trace Message Unstable" defect
condition.
` 1 - Indicates that the VT De-Mapper block is currently declaring the "VT Path Trace Message Unstable" defect
condition.
NOTE: The VT-De-Mapper block will also set this bit-field "0" anytime it receives a given "VT Path Trace Message" 3 (or 5)
consecutive times.
BIT 0 - Unused:
TABLE 452: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER BYTE 0 (ADDRESS = 0XND64, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Change of
Receive APS
Value Composite
Elastic Store
Overflow
Event Composite
R/O
R/O
R/O
R/O
R/O
R/O
RUR
RUR
0
0
0
0
0
0
0
0
Bits 7 - 2: Unused:
Bit 1 - Change of Receive APS Value Interrupt:
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of
314
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Receive APS Value" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt
whenever it has "accepted" a new "APS" value (from the K4 bytes within the incoming VT-data-stream).
` 0 - Indicates that the "Change of Receive APS Value" Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the "Change of Receive APS Value" Interrupt has occurred since the last read of this register.
Bit 0 - Transmit or Receive Elastic Store Overflow Event Interrupt:
This RESET-upon-READ bit-field indicates whether or not the "VT Mapper/VT-De-Mapper" block has generated the
"Elastic Store Overflow Event" Interrupt since the last read of this register. The VT-Mapper/De-Mapper block will
generate this interrupt in response to either of the following conditions.
• Whenever the "Transmit FIFO" within the VT-Mapper Block, experiences an overflow event.
• Whenever the "Receive FIFO" within the VT-De-Mapper Block, experiences an overflow event.
` 0 - Indicates that the channel has NOT generated an "Elastic Store Overflow" Interrupt since the last read of this
register.
` 1 - Indicates that the channel has generated an "Elastic Store Overflow" interrupt since the last read of this register.
TABLE 453: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER BYTE 0 (ADDRESS = 0XND65, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
VT Size
Error
Interrupt
Status
Change of
LOP-V
Defect
Condition
Interrupt
Status
Change of
RFI-V Defect
Condition
Interrupt
Status
Change of
RDI-V Defect
Condition
Interrupt
Status
Change of
AIS-V Failure
Condition
Interrupt
Status
Change of
AIS-V Defect
Condition
Interrupt
Status
Change of
VT Label
Interrupt
Status
Change of
DS1/E1 AIS
Defect
Condition
Interrupt
Status
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0
Bit 7 - VT Size Error Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "VT Size Error"
Interrupt since the last read of this register. The VT-De-Mapper block will generate the "VT Size Error" Interrupt anytime
it declares the "VT Size Error" defect condition.
` 0 - Indicates that the VT Size Error Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the VT Size Error Interrupt has occurred since the last read of this register.
Bit 6 - Change of LOP-V Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of
LOP-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this
interrupt in response to either of the following conditions.
• Whenever the VT-De-Mapper block declares the LOP-V defect condition
• Whenever the VT-De-Mapper block clears the LOP-V defect condition.
` 0 - Indicates that the "Change of LOP-V Defect Condition" Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the "Change of LOP-V Defect Condition" Interrupt has occurred since the last read of this register.
Bit 5 - Change of RFI-V Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of
RFI-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt
in response to either of the following conditions.
• Whenever the VT-De-Mapper block declares the RFI-V defect condition
• Whenever the VT-De-Mapper block clears the RFI-V defect condition.
` 0 - Indicates that the "Change of RFI-V Defect Condition" Interrupt has NOT occurred since the last read of this
315
XRT86SH328
PRELIMINARY
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
register.
` 1 - Indicates that the "Change of RFI-V Defect Condition" Interrupt has occurred since the last read of this register.
Bit 4 - Change of RDI-V Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the
"Change of RDI-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will
generate this interrupt in response to either of the following conditions.
• Whenever the VT-De-Mapper block declares the RDI-V defect condition
• Whenever the VT-De-Mapper block clears the RDI-V defect condition.
` 0 - Indicates that the "Change of RDI-V Defect Condition" Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the "Change of RDI-V Defect Condition" Interrupt has occurred since the last read of this register.
Bit 3 - Change of AIS-V Failure Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of
AIS-V Failure Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this
interrupt in response to either of the following conditions.
• Whenever the VT-De-Mapper block declares the AIS-V failure condition
• Whenever the VT-De-Mapper block clears the AIS-V failure condition.
` 0 - Indicates that the "Change of AIS-V Failure Condition" Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the "Change of AIS-V Failure Condition" Interrupt has occurred since the last read of this register.
Bit 2 - Change of AIS-V Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the
"Change of AIS-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will
generate this interrupt in response to either of the following conditions.
• Whenever the VT-De-Mapper block declares the AIS-V defect condition
• Whenever the VT-De-Mapper block clears the AIS-V defect condition.
0 - Indicates that the "Change of AIS-V Defect Condition" Interrupt has NOT occurred since the last read of this
register.
1 - Indicates that the "Change of AIS-V Defect Condition" Interrupt has occurred since the last read of this
register.
Bit 1 - Change of VT Label Value Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "Change of VT Label Value" Interrupt has occurred since
the last read of this register. The VT-De-Mapper block will generate this interrupt anytime it has "accepted" a new VT
Label value (that it has received via the V5 byte within the incoming VT data-stream).
` 0 - Indicates that the "Change of VT Label Value" Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the "Change of VT Label Value" Interrupt has occurred since the last read of this register.
Bit 0 - Change of DS1/E1 AIS Defect Condition Interrupt Status
This RESET-upon-READ bit-field indicates whether or not the "Change of DS1/E1 AIS Defect Condition"
Interrupt has occurred since the last read of this register. The VT-Mapper block will generate this interrupt in
response to any one of the following conditions.
• Whenever the VT-Mapper block declares the DS1/E1 AIS Defect (with the Ingress Direction T1/E1 traffic).
• Whenever the VT-Mapper block clears the DS1/E1 AIS Defect (within the Ingress Direction T1/E1 traffic)
` 0 - Indicates that the "Change of DS1/E1 AIS Defect Condition" Interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the "Change of DS1/E1 AIS Defect Condition" Interrupt has occurred since the last read of this
register.
316
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 454: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT STATUS REGISTER
(ADDRESS = 0XND67, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
Change of
VT Path
Trace
Message
Unstable
Defect
Condition
Interrupt
Status
New VT Path
Trace
Message
Interrupt
Status
Change of
TIM-V
Defect
Condition
Interrupt
Status
BIT 2
BIT 1
BIT 0
Unused
R/O
R/O
RUR
RUR
RUR
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Bits 7 - 6 - Unused:
Bit 5 - Change of VT Path Trace Message Unstable Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the "Change of VT Path Trace Message Unstable Defect
Condition" Interrupt has occurred since the last read of this register. The VT-De-Mapper block will generate this interrupt
in response to either of the following conditions.
• Whenever the VT-De-Mapper block declares the "VT Path Trace Message Unstable" Defect condition.
• Whenever the VT De-Mapper block clears the "VT Path Trace Message Unstable" Defect condition.
` 0 - Indicates that the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt has NOT occurred
since the last read of this register.
` 1 - Indicates that the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt has occurred since
the last read of this register.
Bit 4 - New VT Path Trace Message Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the "New VT Path Trace Message" Interrupt has occurred
since the last read of this register. The VT-De-Mapper block will generate this interrupt whenever it has "accepted" a
new "VT Path Trace Message" via the incoming VT-data-stream.
` 0 - Indicates that the "New VT Path Trace Message" Interrupt has NOT occurred since the last read of this register.
` 1 - Indicates that the "New VT Path Trace Message" Interrupt has occurred since the last read of this register.
Bit 3 - Change of TIM-V Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of
TIM-V Defect Condition" interrupt since the last read of this register. The VT-De-Mapper block will generate this
interrupt in response to either of the following conditions.
• Whenever it declares the TIM-V Defect condition.
• Whenever it clears the TIM-V Defect condition.
` 0 - Indicates that the "Change of TIM-V Defect Condition" interrupt has NOT occurred since the last read of this
register.
` 1 - Indicates that the "Change of TIM-V Defect Condition" interrupt has occurred since the last read of this register.
Bits 2 - 0 - Unused:
317
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 455: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER
(ADDRESS = 0XND68, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
Unused
BIT 1
BIT 0
Change of
Receive APS
Value
Interrupt
Enable
Elastic Store
Overflow
Event
Interrupt
Enable
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 2: Unused:
Bit 1 - Change of Receive APS Value Interrupt Enable:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive APS Value" Interrupt.
If the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt anytime it has "accepted" a
new APS value (via the K4 byte within the incoming VT-data-stream).
` 0 - Disables the "Change of Receive APS Value" Interrupt.
` 1 - Enables the "Change of Receive APS Value" Interrupt.
Bit 0 - Transmit or Receive Elastic Store Overflow Event Interrupt Enable:
This READ/WRITE bit-field permits the user to either enable or disable the "Elastic Store Overflow Event" interrupt. If
the user enables this interrupt, then the channel will generate this interrupt in response to either of the following
conditions.
• Whenever the "Transmit FIFO" within the VT-Mapper Block, experiences an overflow event.
• Whenever the "Receive FIFO" within the VT-De-Mapper block, experiences an overflow event.
` 0 - Disables the "Elastic Store Overflow Event" Interrupt
` 1 - Enables the "Elastic Store Overflow Event" Interrupt
TABLE 456: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER
(ADDRESS = 0XND69, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
VT Size
Error
Interrupt
Enable
Change of
LOP-V
Defect
Condition I
nterrupt
Enable
Change of
RFI-V Defect
Condition
Interrupt
Enable
Change of
RDI-V Defect
Condition
Interrupt
Enable
Change of
AIS-V
Failure
Condition
Interrupt
Enable
Change of
AIS-V Defect
Condition
Interrupt
Enable
Change of
VT Label
Interrupt
Enable
Change of
DS1/E1
AIS Defect
Condition
Interrupt
Enable
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bit 7 - VT Size Error Interrupt Enable:
This READ/WRITE bit-field permits the user to either enable or disable the "VT Size Error" Interrupt. If the user enables
this interrupt, then the "VT-De-Mapper" block will generate this interrupt anytime it declares the "VT Size Error" defect
condition.
• 0 - Disables the "VT Size Error" Interrupt.
• 1 - Enables the "VT Size Error" Interrupt.
Bit 6 - Change of LOP-V Defect Condition Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of LOP-V Defect Condition"
318
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to
either of the following conditions.
• Whenever it declares the LOP-V Defect Condition
• Whenever it clears the LOP-V Defect condition
` 0 - Disables the "Change of LOP-V Defect Condition" Interrupt
` 1 - Enables the "Change of LOP-V Defect Condition" Interrupt
Bit 5 - Change of RFI-V Defect Condition Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of RFI-V Defect Condition"
Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to
either of the following conditions.
• Whenever it declares the RFI-V Defect Condition
• Whenever it clears the RFI-V Defect condition
` 0 - Disables the "Change of RFI-V Defect Condition" Interrupt
` 1 - Enables the "Change of RFI-V Defect Condition" Interrupt
Bit 4 - Change of RDI-V Defect Condition Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of RDI-V Defect Condition"
Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to
either of the following conditions.
• Whenever it declares the RDI-V Defect Condition
• Whenever it clears the RDI-V Defect condition
` 0 - Disables the "Change of RDI-V Defect Condition" Interrupt
` 1 - Enables the "Change of RDI-V Defect Condition" Interrupt
Bit 3 - Change of AIS-V Failure Condition Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of AIS-V Failure Condition"
Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to
either of the following conditions.
• Whenever it declares the AIS-V Failure Condition
• Whenever it clears the AIS-V Failure condition
` 0 - Disables the "Change of AIS-V Failure Condition" Interrupt
` 1 - Enables the "Change of AIS-V Failure Condition" Interrupt
Bit 2 - Change of AIS-V Defect Condition Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of AIS-V Defect Condition"
Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to
either of the following conditions.
• Whenever it declares the AIS-V Defect Condition
• Whenever it clears the AIS-V Defect condition
` 0 - Disables the "Change of AIS-V Defect Condition" Interrupt
` 1 - Enables the "Change of AIS-V Defect Condition" Interrupt
Bit 1 - Change of VT Label Value Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of VT Label Value" Interrupt. If the
user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt anytime it has "accepted" a new
"VT Label Value" via the V5 bytes within the incoming VT-data-stream.
` 0 - Disables the "Change of VT Label Value" Interrupt.
` 1 - Enables the "Change of VT Label Value" Interrupt.
Bit 0 - Change of DS1/E1 AIS Defect Condition Interrupt Enable
This READ/WRITE bit-field permits the user to either enable or disable the "Change of DS1/E1 AIS Defect Condition"
interrupt. If the user enables this interrupt, then the "VT-Mapper" block will generate this interrupt in response to either
319
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
of the following events.
• Whenever it declares the DS1/E1 AIS defect condition.
• Whenever it clears the DS1/E1 AIS defect condition
` 0 - Disables the "Change of DS1/E1 AIS Defect Condition" interrupt.
` 1 - Enables the "Change of DS1/E1 AIS Defect Condition" interrupt.
TABLE 457: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER
(ADDRESS = 0XND6B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
Change of VT
Path Trace
Message
Unstable Defect
Condition
Interrupt Enable
New VT Path
Trace Message
Interrupt Status
Change of TIM-V
Defect Condition
Interrupt Status
BIT 2
BIT 1
BIT 0
Unused
R/O
R/O
RUR
RUR
RUR
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Bits 7 - 6 - Unused:
Bit 5 - Change of VT Path Trace Message Unstable Defect Condition Interrupt Enable:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of VT Path Trace Message
Unstable Defect Condition" interrupt. If the user enables this interrupt, then the VT-De-Mapper block will generate this
interrupt in response to either of the following events.
• Whenever the VT-De-Mapper block declares the "VT-Path Trace Message Unstable" defect condition.
• Whenever the VT-De-Mapper block clears the "VT-Path Trace Message Unstable" defect condition.
` 0 - Disables the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt.
` 1 - Enables the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt.
Bit 4 - New VT Path Trace Message Interrupt Enable:
This READ/WRITE bit-field permits the user to either enable or disable the "New VT Path Trace Message" Interrupt. If
the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt whenever it has "accepted" a
new "VT Path Trace Message" via the incoming VT-data-stream.
` 0 - Disables the "New VT Path Trace Message" Interrupt.
` 1 - Enables the "New VT Path Trace Message" Interrupt
Bit 3 - Change of TIM-V Defect Condition Interrupt Enable:
This READ/WRITE bit-field permits the user to either enable or disable the "Change of TIM-V Defect
Condition" Interrupt. If the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt
in response to either of the following events.
• Whenever it declares the TIM-V Defect Condition
• Whenever it clears the TIM-V Defect Condition
` 0 - Disables the "Change of TIM-V Defect Condition" Interrupt
` 1 - Enables the "Change of TIM-V Defect Condition" Interrupt
Bits 2 - 0 - Unused:
320
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 458: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - VT-PATH TRACE BUFFER
CONTROL REGISTER (ADDRESS = 0XND71, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
Reserved
BIT 5
BIT 4
BIT 3
BIT 2
Unused
Receive VT
Path Trace
Message
Buffer Select
VT Path
Trace
Message
Accept
Threshold
VT Path
Trace
Message
Type
BIT 1
BIT 0
VT Path Trace Message
Length[1:0]
R/W
R/W
RUR
RUR
RUR
R/O
R/O
R/O
0
0
0
0
0
0
0
0
Bit 7 - 6 - Reserved
For Normal Operation, please set these two bit-fields to "0".
Bit 5 - Unused
Bit 4 - Receive VT Path Trace Message Buffer Select:
This READ/WRITE bit-field permits a user to specify which of the following "Receive VT Path Trace Message"
buffer segments that the Microprocessor will read out whenever it reads out the contents of the Receive Path
Trace Message buffer.
a.
The "Actual" Receive VT Path Trace Message Buffer. The "Actual" Receive VT Path Trace Message Buffer
contains the contents of the most recently received (and accepted) VT Path Trace Messages via the incoming
VT-data-stream.
b.
The "Expected" Receive VT Path Trace Message Buffer. The "Expected" Receive Path Trace Message
Buffer contains the contents of the "VT Path Trace Message" that the user "expects" to receive. The contents
of this particular buffer are usually specified by the user.
` 0 - Configures the chip to return the contents of the "Actual" Receive VT Path Trace Message" Buffer, whenever the
user executes a READ to the "Receive VT Path Trace Message" Buffer.
` 1 - Configures the chip to return the contents of the "Expected" Receive VT Path Trace Message" Buffer, whenever
the user executes a READ to the "Receive VT Path Trace Message" Buffer.
Bit 3 - Receive VT Path Trace Message Accept Threshold
This READ/WRITE bit-field permits a user to select the number of consecutive times that the "VT-De-Mapper" block
must receive a given "VT Path Trace Message" before it is "validated" and loaded into the "Actual" Receive VT Path
Trace Message Buffer, as described below.
` 0 - Configures the VT-De-Mapper block to "validate" the incoming VT Path Trace Message after it has received it the
third time in succession.
` 1 - Configures the VT-De-Mapper block to "validate" the incoming VT Path Trace Message after it has received it the
fifth time in succession.
Bit 2 - Receive VT Path Trace Message Type
This READ/WRITE bit-field permits the user to specify how the "VT-De-Mapper" block will locate the boundary
of the incoming VT Path Trace Message (within the incoming VT-data-stream) as depicted below.
` 0 - Configures the VT-De-Mapper block to expect the "VT Path Trace Message" boundary to be denoted by a "Line
Feed" character.
` 1 - Configures the VT-De-Mapper block to except the "VT Path Trace Message" boundary to be denoted by the
presence of a "1" in the "MSB" (Most Significant bit) of the first byte (within the incoming VT Path Trace Message). In
this case, all of the remaining bytes (within the incoming VT Path Trace Message) will each have a "0" within their MSBs.
Bits 1 - 0 - VT Path Trace Message Length[1:0]:
These READ/WRITE bit-fields permit the user to specify the length of the "Receive VT Path Trace Message that the
"VT-De-Mapper" block will accept and load into the "Actual" Receive VT Path Trace Message Buffer. The relationship
between the contents of these bit-fields and the corresponding "Receive VT Path Trace Message" Length is presented
321
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
below.
VT PATH TRACE MESSAGE
LENGTH[1:0]
RESULTING VT PATH TRACE
MESSAGE LENGTH (BYTES)
00
1
01
16
1X
64
TABLE 459: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER BYTE 1 (ADDRESS = 0XND72, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
Unused
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Auto Transmit AIS-V
upon AIS-V
Defect
Auto Transmit AIS-V
upon UNEQV Defect
Unused
Auto Transmit AIS-V
upon LOP-V
Defect
Auto Transmit AIS-V
upon PLM-V
Defect
Unused
R/O
R/O
R/W
R/W
R/O
R/W
R/W
R/O
0
0
0
0
0
0
0
0
Bits 7 - 6 - Unused:
Bit 5 - Auto Transmit AIS-V upon AIS-V Defect:
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration
that) it declares the AIS-V defect condition within the incoming VT-data-stream.
` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream"
traffic) whenever it declares the AIS-V defect condition.
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic)
whenever it declares the AIS-V defect condition.
NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to
automatically transmit the AIS-V indicator, in response to this defect condition.
Bit 4 - Auto Transmit AIS-V upon UNEQ-V Defect:
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration
that) it declares the UNEQ-V defect condition within the incoming VT-data-stream.
` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream"
traffic) whenever it declares the UNEQ-V defect condition.
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic)
whenever it declares the UNEQ-V defect condition.
NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to
automatically transmit the AIS-V indicator, in response to this defect condition.
Bit 3 - Unused:
Bit 2 - Auto Transmit AIS-V upon LOP-V Defect:
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration
that) it declares the LOP-V defect condition within the incoming VT-data-stream.
` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream"
traffic) whenever it declares the LOP-V defect condition.
322
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic)
whenever it declares the LOP-V defect condition.
NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to
automatically transmit the AIS-V indicator, in response to this defect condition.
Bit 1 - Auto Transmit AIS-V upon PLM-V Defect:
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration
that) it declares the PLM-V defect condition within the incoming VT-data-stream.
` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream"
traffic) whenever it declares the PLM-V defect condition.
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic)
whenever it declares the PLM-V defect condition.
NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to
automatically transmit the AIS-V indicator, in response to this defect condition.
Bit 0 - Unused:
TABLE 460: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER BYTE 0 (ADDRESS = 0XND73, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Auto
Transmit
AIS-V upon
VT Path
Trace
Message
Unstable
Defect
Auto
Transmit
AIS-V upon
TIM-V Defect
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Reserved (Set to "[0, 0, 0, 0, 0]" for Normal Operation)
BIT 0
Auto
Transmit
AIS-V
Enable
Bit 7 - Auto Transmit AIS-V upon VT Path Trace Message Unstable Defect:
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration
that) it declares the VT Path Trace Message Unstable defect condition within the incoming VT-data-stream.
` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream"
traffic) whenever it declares the VT Path Trace Message Unstable defect condition.
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic)
whenever it declares the VT Path Trace Message Unstable defect condition.
NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to
automatically transmit the AIS-V indicator, in response to this defect condition.
Bit 6 - Auto Transmit AIS-V upon TIM-V Defect:
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration
that) it declares the TIM-V defect condition within the incoming VT-data-stream.
` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream"
traffic) whenever it declares the TIM-V defect condition.
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic)
whenever it declares the TIM-V defect condition.
323
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to
automatically transmit the AIS-V indicator, in response to this defect condition.
Bits 5 - 1 - Reserved:
Please set each of these bit-fields to "0" for normal operation.
Bit 0 - Auto Transmit AIS-V Enable
This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V
indicator (via the down-stream traffic) whenever (and for the duration that) it declares either the AIS-V, LOP-V, TIM-V,
UNEQ-V, PLM-V or "VT Path Trace Message Unstable" defect conditions.
` 0 - Configures the VT-De-Mapper block to NOT automatically transmit the AIS-V indicator (via the "downstream
traffic) upon declaration of any of the "above-mentioned" defect conditions.
` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream traffic)
upon declaration of any of the "above-mentioned" defect conditions.
NOTE: The user must also set the corresponding bit-fields (within this register) to "1" in order to configure the VT-DeMapper block to automatically transmit the AIS-V indicator upon detection of a given alarm/defect condition.
TABLE 461: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT J2 BYTE VALUE REGISTER
(ADDRESS = 0XND76, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit J2 Byte Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 0 - Transmit J2 Byte Value[7:0]:
These READ/WRITE bit-fields permit the user to have software control over the value of the J2 byte, within the outbound
VT data-stream.
If the user configures the VT-Mapper block to use this register as the source of the J2 byte, then it will automatically
write the contents of this register into the J2 byte location, within each "outbound" VT multi-frame.
This feature is enabled whenever the user writes the value "[1, 0]" into Bits 1 and 0 (Transmit VT-Path Trace Message
Source[1:0]) within the "Channel Control - VT Mapper Block - Ingress Direction - VT Path Trace Message Control"
Register.
TABLE 462: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT N2 BYTE VALUE
REGISTER (ADDRESS = 0XND77, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit N2 Byte Value[7:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 0 - Transmit N2 Byte Value[7:0]:
These READ/WRITE bit-fields permit the user to have software control over the value of the N2 byte, within the
outbound VT data-stream.
The VT-Mapper block will (unconditionally) use this register as the source of the N2 byte, then it will
automatically write the contents of this register into the J2 byte location, within each "outbound" VT multiframe.
324
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
TABLE 463: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT VT-PATH TRACE
MESSAGE CONTROL REGISTER (ADDRESS = 0XND79, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
Reserved
BIT 4
BIT 3
Unused
BIT 2
Transmit VT Path Trace
Message Length[1:0]
BIT 1
BIT 0
Transmit VT Path Trace
Message Source[1:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
0
Bits 7 - 6 - Reserved:
NOTE: The user must set these two bits to "[0, 0]" for normal operation.
Bit 5 - TxAIS:
Bit 4 - Unused:
Bits 3 - 2 - Transmit VT Path Trace Message Length[1:0]:
These READ/WRITE bit-fields permit the user to specify the length of the VT Path Trace Message that the VT-Mapper
block will repeatedly transmit to the remote VT PTE. The relationship between the contents of these bit-fields and the
corresponding VT Path Trace Message Length is presented below.
TRANSMIT VT PATH TRACE
MESSAGE LENGTH[1:0]
RESULTING VT PATH TRACE MESSAGE
LENGTH (IN TERMS OF BYTES)
00
1 Byte
01
16 Bytes
1X
64 Bytes
Bits 1 - 0 - Transmit VT Path Trace Message Source[1:0]:
These READ/WRITE bit-fields permit the user to specify the source of the "outbound" VT Path Trace Message
that will transported via the J2 byte channel (within the outbound VT-data-stream) as depicted below.
TRANSMIT VT PATH TRACE
MESSAGE SOURCE[1:0]
RESULTING SOURCE OF THE VT PATH TRACE MESSAGE
00
Fixed Value:The VT-Mapper block will automatically set the J2 byte, within the each outbound VT-multi-frame to the value "0x01".
01
The Transmit VT Path Trace Message Buffer:The VT-Mapper Block will read out the contents within the "Transmit VT-Path Trace Message" Buffer, and will transmit this message to
the remote VT PTE.
10
From the "Transmit J2 Byte Value[7:0]" Register:In this setting, the VT-Mapper block will
read out the contents of the "Transmit J2 Byte Value Register, and will insert this value into
the J2 byte-position within each outbound VT-multi-frame.
11
DO NOT USE
325
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 464: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL
REGISTER - BYTE 3 (ADDRESS = 0XND84, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Unused
PLM-V RDI
CODE[2:0]
Transmit
RDI-V upon
PLM-V
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
1
0
0
Bits 7 - 4 - Unused:
Bits 3- 1 - PLM-V RDI Code[2:0]:
These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within
the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the
corresponding VT-De-Mapper block detects and declare the PLM-V defect condition.
NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon PLM-V) within this register to "1".
Bit 0 - Transmit RDI-V upon PLM-V
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code
(as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that)
the corresponding VT-De-Mapper block declares the PLM-V defect condition.
` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for
the duration that) the corresponding VT-De-Mapper block declares the PLM-V defect condition.
` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the
duration that) the corresponding VT-De-Mapper block declares the PLM-V defect condition.
TABLE 465: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL
REGISTER - BYTE 2 (ADDRESS = 0XND85, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
TIM-V RDI CODE[2:0]
BIT 4
BIT 3
Transmit
RDI-V upon
TIM-V
BIT 2
BIT 1
UNEQ-V RDI CODE[2:0]
BIT 0
Transmit
RDI-V upon
UNEQ-V
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
1
0
0
1
1
0
0
Bits 7 - 5 - TIM-V RDI Code[2:0]:
These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within
the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the
corresponding VT-De-Mapper block detects and declare the TIM-V defect condition.
NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon TIM-V) within this register to "1".
Bit 4 - Transmit RDI-V upon TIM-V
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code
(as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that)
the corresponding VT-De-Mapper block declares the TIM-V defect condition.
` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for
the duration that) the corresponding VT-De-Mapper block declares the TIM-V defect condition.
` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the
duration that) the corresponding VT-De-Mapper block declares the TIM-V defect condition.
Bits 3 - 1 - UNEQ-V RDI Code[2:0]:
326
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within
the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the
corresponding VT-De-Mapper block detects and declare the UNEQ-V defect condition.
NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon UNEQ-V) within this register to "1".
Bit 0 - Transmit RDI-V upon UNEQ-V
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code
(as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that)
the corresponding VT-De-Mapper block declares the UNEQ-V defect condition.
` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for
the duration that) the corresponding VT-De-Mapper block declares the UNEQ-V defect condition.
` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the
duration that) the corresponding VT-De-Mapper block declares the UNEQ-V defect condition.
TABLE 466: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL
REGISTER - BYTE 1 (ADDRESS = 0XND86, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
BIT 5
LOP-V RDI CODE[2:0]
BIT 4
BIT 3
Transmit
RDI-V upon
LOP-V
BIT 2
BIT 1
AIS-V RDI CODE[2:0]
BIT 0
Transmit
RDI-V upon
AIS-V
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
Bits 7 - 5 - LOP-V RDI Code[2:0]:
These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within
the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the
corresponding VT-De-Mapper block detects and declare the LOP-V defect condition.
NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon LOP-V) within this register to "1".
Bit 4 - Transmit RDI-V upon LOP-V
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code
(as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that)
the corresponding VT-De-Mapper block declares the LOP-V defect condition.
` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for
the duration that) the corresponding VT-De-Mapper block declares the LOP-V defect condition.
` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the
duration that) the corresponding VT-De-Mapper block declares the LOP-V defect condition.
Bits 3 - 1 - AIS-V RDI Code[2:0]:
These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within
the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the
corresponding VT-De-Mapper block detects and declare the AIS-V defect condition.
NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon AIS-V) within this register to "1".
Bit 0 - Transmit RDI-V upon AIS-V
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code
(as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that)
the corresponding VT-De-Mapper block declares the AIS-V defect condition.
` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for
the duration that) the corresponding VT-De-Mapper block declares the AIS-V defect condition.
` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the
duration that) the corresponding VT-De-Mapper block declares the AIS-V defect condition.
327
PRELIMINARY
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6
TABLE 467: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL
REGISTER - BYTE 0 (ADDRESS = 0XND87, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C)
BIT 7
BIT 6
RFI-V upon
DS1/E1 RAI
Enable
BIT 5
BIT 4
Unused
BIT 3
BIT 2
BIT 1
BIT 0
Transmit RDI-V Value[2:0]
RDI-V Type
RDI-V Insert
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0
1
0
1
0
1
0
Bit 7 - RFI-V upon DS1/E1 RAI Enable:
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RFI-V
indicator (within the outbound VT-data-stream) whenever (and for the duration) that the corresponding Ingress Direction
Receive DS1/E1 Framer block declares the RAI defect condition.
` 0 - Does not configure the VT-Mapper block to automatically transmit the RFI-V indicator whenever (and for the
duration) that the corresponding Ingress Direction Receive DS1/E1 Framer block declares the RAI defect condition.
` 1 - Configures the VT-Mapper block to automatically transmit the RFI-V indicator whenever (and for the duration) that
the corresponding Ingress Direction Receive DS1/E1 Framer block declares the RAI defect condition.
Bits 6 - 5 - Unused:
Bits 4 - 2 - Transit RDI-V Value[2:0]:
These three READ/WRITE bit-fields permits the user to specify the value that the VT-Mapper block will transmit, within
the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) regardless of any defects that the corresponding
VT-De-Mapper block is (or is NOT) currently declaring.
NOTE: The user MUST set bit 0 (RDI-V Insert Type) within this register to "1" in order to configure the VT-Mapper block to
use these bit-fields as the "source" of the RDI-V value.
Bit 1 - RDI-V Type
This READ/WRITE bit-field permits the user to configure the VT-Mapper block to either support the "SRDI-V" (SingleBit - RDI-V) or "ERDI-V" (Extended - RDI-V) form of signaling. If the user opts to use only "Single-Bit" RDI-V, then the
RDI-V indicator will only be transported via Bit 8 (RDI-V) within the V5 byte in a VT-data-stream. Conversely, if the user
opts to use the "Extended" RDI-V, then the RDI-V indicator will be transported via both Bit 8 (RDI-V) within the V5 byte,
and Bits 5, 6 and 7 within the Z7/K4 byte.
` 0 - Configures the VT Mapper block to use the SRDI-V form of signaling.
` 1 - Configures the VT-Mapper block to use the ERDI-V form of signaling.
NOTE: This configuration setting only applies to the VT-Mapper block. If the user wishes to configure the VT-De-Mappe
block to support either the "SRDI-V" or the "ERDI-V" form of signaling, then he/she must set Bit 0 (RDI-V Type)
within the "Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop Control Register - Byte 2.
Bit 0 - RDI-V Insert Type:
This READ/WRITE bit-field permits the user to select the source of the RDI-V code word that the VT-Mapper block will
transmit within the outbound VT-data-stream, as depicted below. In this case, the user has two options.
• To configure the VT-Mapper block to transmit the appropriate RDI-V code (based upon defects that the
corresponding VT-De-Mapper block declares). In this case, the VT-Mapper block will transmit the RDI-V codes, as
configured in the "Channel Control - VT Mapper Block - Ingress Direction - Transmit RDI-V Control Register - Bytes 3
- 1" registers.
• To configure the VT-Mapper block to use the value written into the "Transmit RDI-V Value[2:0]" bit-fields within this
register.
` 0 - Configures the VT-Mapper block to transmit the appropriate RDI-V code (based upon defects that the
corresponding VT-De-Mapper block declares).
` 1 - Configures the VT-Mapper block to use the value written into the "Transmit RDI-V Value[2:0]" bit-fields within this
register.
328
PRELIMINARY
REV. P1.0.6
XRT86SH328
28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS
REVISIONS
DATE
REV #
DESCRIPTION
09/09/06
P1.0.0
Initial issue of register information.
11/09/06
P1.0.5
Made edits to register map.
1/17/07
P1.0.6
Made edits to register map and register definitions.
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to
improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any
circuits described herein, conveys no license under any patent or other right, and makes no representation that
the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration
purposes and may vary depending upon a user’s specific application. While the information in this publication
has been carefully checked; no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the
failure or malfunction of the product can reasonably be expected to cause failure of the life support system or
to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless
EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has
been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately
protected under the circumstances.
Copyright 2007 EXAR Corporation
Datasheet January 2007.
All effort hs been made to provide correct information in this data sheet, iIf discrepencies are found or more
information is required please contact Exar Application Engineering at <[email protected]>
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
329