PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET JANUARY 2007 GENERAL DESCRIPTION The XRT86SH328 is an integrated VT/TU Mapper with 28 port T1/E1 Line Interface Units. The XRT86SH328 contains integrated DS1/E1/J1 Framers for performance monitoring. The XRT86SH328 processes the Section, Line and Path overhead in the SONET/SDH data-stream. The processing of path overhead bytes within the STS-1s or TUG-3s include 64 bytes (of buffer) for storing the (Section Trace and Path Trace) messages. Path Overhead bytes can be accessed either by on-chip registers or a Serial Output Port. Each of the 28 T1 or E1 Channels use an internal DeSynchronizer circuit with an internal pointer leak algorithm. This removes the jitter due to mapping and pointer adjustments from the T1 or E1 signals that are de-mapped from the incoming SONET/SDH datastream. These De-Synchronizer circuits do not need any external clock references for its operation. The Transmit Blocks permit flexible insertion of TOH and POH bytes via both Hardware and Software control. The Receive Blocks receive a SONET STS-1 signals or an SDH STM-1 signal and performs the necessary Transport and Path Overhead Processing. A PRBS Pattern Generator and Receiver is implemented within each of the 28 T1/E1 channels in order to implement and measure Bit-Error performance. A general purpose Microprocessor Interface is included for control, configuration and monitoring. FEATURES • Provides mapping of up to 28 T1 streams as Asynchronous VT1.5 into an STS-1 SPE or TU-11 tributary unit into an STM-1/VC-3 or TUG-3 from STM-1/ VC-4 • Supports 28 T1 streams M13 multiplexed into a serial DS3 • Supports 21 E1 streams M13 multiplexed into a serial DS3 (compliant with ITU-T G.747) • 28 T1 Streams M13 Multiplexed into a DS3 and DS3 is asynchronously mapped into STS-1. • 21 E1 Streams M13 Multiplexed into a DS3 (ITU-T G.747) REV. P1.0.6 • Supports 21 E1 mapped as Asynchronous VT2 into an STS-1 SPE or TU-12 tributary units into STM-1/VC-3 or TUG-3 from a STM-1/VC-4. • Supports TU cross-mapping function TU-12/VC-11/T1. • Supports mixed mapping of VT-G/VT1.5 and VT-G/VT2. • Supports mixed mapping of TUG-2/TU-11 and TUG-2/ TU-12 • 28 VT1.5/TU-11 or 21 VT-2/TU-12 tributaries can be passed as transparent between SONET/SDH Telecom Bus on the line side and Clock and Data on the system side. • Supports Unframed T1/E1 signals • Supports DS1/E1 Performance Monitoring in both Egress and Ingress direction • VC-11/VC-12 Tandem Connection Monitoring support • Complies with the Category I Intrinsic Jitter Requirements for DS1 signals being de-mapped from SONET, per Telcordia GR-253-CORE • Complies with the "Mapping Jitter Generation Specification" for DS1 and E1 signals being de-mapped from SDH, per ITU-T G.783 • Complies with the "Combined Jitter Generation Specification" for DS1 and E1 signals being de-mapped from SDH, per ITU-T G.783 • Line and Facility Loop-backs • Each of the 28 T1/E1 Channels includes a PRBS Generator and Receiver. • Each of the 28 VT-Mapper blocks are capable of generating BIP-2 and REI errors upon software command (for diagnostic purposes). • ·The Transmit and Receive DS3 Framer blocks support both the M13(M23) and the C-bit Parity Framing formats. • Integrated 28 T1/E1/J1 Short-Haul Line Interface Units • IEEE 1149.1 Standard Boundary Scan • Low Power: 1.8V Power Supply for Core Logic; 3.3V Power Supply for I/O • General Purpose Microprocessor Interface APPLICATIONS • Channelized and Unchannelized DS3 applications • T1/E1 Terminals • SONET/SDH ADM and DS3 is asynchronously mapped into STS-1. Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 1. BLOCK DIAGRAM OF THE XRT86SH328 ST S-1/ STS-1/ ST S-3 STS-3 Telecom T elecom BBus us Interface Interface TTransm ransmitit ST STS-1/3 S-1/3 TTOOHH Processor Processor BBlock lock TTransm ransmitit ST S-1 PO STS-1 POHH Processor Processor BBlock lock VVT/T T /TUU MMapper apper BBlock lock Ingress D irection T ransm it D S1/E 1 Fram er Block Ingress D irection R eceive D S1/E 1 Fram er B lock R eceive D S1/E 1 LIU B lock D S1/E 1 C hannel 0 From D S1/E1 C hannels 1 - 27 From DS2 C hannels 1 - 6 DDS3/ S3/ ST S-1 STS-1 LLIU IU Interface Interface TTransm ransm itit DDS3 S3 Fram Framerer BBlock lock MM23 23 MMUUXX BBlock lock RReceive eceive DDS3 S3 Fram Framerer BBlock lock MM23 23 DDe-M e-MUUXX BBlock lock M 12 M UX B lock From D S1/E 1 C hannels 1 - 3 D S2 C hannel 0 M 12 D e-M U X B lock To D S1/E 1 C hannels 1 - 3 D S2 C hannel 0 To D S1/E 1 C hannels 1 - 27 RReceive eceive ST STS-1/3 S-1/3 TTOOHH Processor Processor BBlock lock RReceive eceive ST STS-1 S-1PO POHH Processor Processor BBlock lock To D S2 C hannels 1 - 6 VT /T U D e-M apper B lock D S1/E1 Jitter A tten B lock E gress D irection R eceive D S1/E 1 Fram er B lock E gress D irection T ransm it D S1/E 1 Fram er B lock Transm it D S1/E 1 L IU B lock D S1/E 1 C hannel 0 TABLE 1: ORDERING INFORMATION PRODUCT NUMBER PACKAGE TYPE OPERATING TEMPERATURE RANGE XRT86SH328IB 568 Ball BGA -40°C to +85°C 2 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS FIGURE 2. PIN OUT OF THE XRT86SH328 (BOTTOM VIEW) 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H J K L M N P R T U V W Y AA AB AC AD AE AF AG AH AJ AK 3 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE OF CONTENTS GENERAL DESCRIPTION ................................................................................................ 1 FEATURES ................................................................................................................................................. 1 APPLICATIONS .......................................................................................................................................... 1 FIGURE 1. BLOCK DIAGRAM OF THE XRT86SH328 .......................................................................................................................... 2 TABLE 1: ORDERING INFORMATION ................................................................................................................................................... 2 FIGURE 2. PIN OUT OF THE XRT86SH328 (BOTTOM VIEW) ............................................................................................................... 3 TABLE OF CONTENTS ............................................................................................................ I 1.0 REGISTER MAP & DESCRIPTION FOR THE XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX AND VT-MAPPER IC - SONET APPLICATIONS................................................................... 4 1.1 REGISTER MAP OF THE XRT86SH328 ............................................................................................................. 4 TABLE 2: OPERATION CONTROL REGISTERS ..................................................................................................................................... 4 TABLE 3: LIU COMMON CONTROL REGISTERS .................................................................................................................................. 5 TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ........................................................................................... 6 TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ......................................................................................... 10 TABLE 6: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER ......................................................... 12 TABLE 7: RECEIVE STS-1/STS-3 PATH - RECEIVE PATH TRACE MESSAGE BUFFER ........................................................................ 12 TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ................................................ 12 TABLE 9: RECEIVE TU-3 POH PROCESSOR BLOCK - RECEIVE PATH TRACE MESSAGE BUFFER (SDH/TUG-3 APPLICATIONS ONLY) 15 TABLE 10: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ..................................................................................... 15 TABLE 11: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ..................................................................................... 17 TABLE 12: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER .................................... 18 TABLE 13: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ................................... 18 TABLE 14: TRANSMIT TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ............................................ 19 TABLE 15: TRANSMIT TU-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ................................................. 20 TABLE 16: VT MAPPER CONTROL REGISTERS ................................................................................................................................ 20 TABLE 17: DS3 MAPPER CONTROL REGISTERS .............................................................................................................................. 21 TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS .......................................................................................................... 22 TABLE 19: T1/E1 LIU CHANNEL CONTROL REGISTERS (WHERE N RANGES FROM 0X01 TO 0X1D) ................................................... 27 TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................... 28 TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ...................................... 30 TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................... 37 TABLE 23: T1/E1 PERFORMANCE MONITOR REGISTER (WHERE N RANGES VALUE FROM 0X01 TO 0X38) .......................................... 39 TABLE 24: T1/E1 FRAMER BLOCK INTERRUPT REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................. 39 TABLE 25: VT MAPPER REGISTER (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................... 41 2.0 REGISTER DESCRIPTIONS.................................................................................................................. 42 TABLE 26: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000) ................................................................................... 42 2.1 OPERATION CONTROL REGISTERS.............................................................................................................. 43 TABLE 27: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000) ................................................................................... 43 TABLE 28: OPERATION CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0001) ................................................................................... 44 TABLE 29: OPERATION CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0003) ................................................................................... 45 TABLE 30: DEVICE ID VALUE REGISTER - BYTE 3 (ADDRESS = 0X0004) ......................................................................................... 45 TABLE 31: REVISION NUMBER VALUE REGISTER - BYTE 2 (ADDRESS = 0X0005) ............................................................................. 46 TABLE 32: OPERATION INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X000B) .................................................................... 46 TABLE 33: OPERATION INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X000F) .................................................................... 46 TABLE 34: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS = 0X0012) ......................................................... 47 TABLE 35: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0013) ......................................................... 48 TABLE 36: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS = 0X0016) ......................................................... 48 TABLE 37: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0017) ......................................................... 50 TABLE 38: MODE CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001B) ........................................................................................... 51 TABLE 39: LOOP-BACK CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001F) ................................................................................... 51 TABLE 40: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0034) ........................................................ 52 TABLE 41: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0035) ........................................................ 52 TABLE 42: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036) ............................................. 53 TABLE 43: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036) ............................................. 55 TABLE 44: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0037) ............................................. 57 TABLE 45: OPERATION BLOCK - INTERFACE CONTROL REGISTER (ADDRESS = 0X003C) .................................................................. 59 TABLE 46: OPERATION GENERAL PURPOSE INPUT/OUTPUT REGISTER - BYTE 0 (ADDRESS = 0X0047) ............................................ 59 TABLE 47: OPERATION GENERAL PURPOSE INPUT/OUTPUT DIRECTION REGISTER 0 (ADDRESS = 0X004B) ...................................... 60 TABLE 48: OPERATION I/O CONTROL REGISTER (ADDRESS = 0X004F) .......................................................................................... 60 TABLE 49: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0050) .......... 61 TABLE 50: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0051) .......... 62 TABLE 51: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0052) .......... 62 I PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 52: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0053) .......... 63 TABLE 53: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0054) ....... 63 TABLE 54: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0055) ....... 63 TABLE 55: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0056) ....... 64 TABLE 56: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0057) ....... 64 TABLE 57: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0058) ................................. 65 TABLE 58: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0059) ................................ 65 TABLE 59: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005A) ................................ 65 TABLE 60: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005B) ................................ 66 TABLE 61: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005C) ................................. 66 TABLE 62: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005D) ................................ 66 TABLE 63: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005E) ................................. 67 TABLE 64: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005F) ................................ 67 2.2 LIU COMMON CONTROL REGISTERS ........................................................................................................... 67 TABLE 65: LIU COMMON CONTROL REGISTER 0 (ADDRESS = 0X0100) ........................................................................................... 67 TABLE 66: LIU COMMON CONTROL REGISTER 1 (ADDRESS = 0X0101) ........................................................................................... 68 TABLE 67: LIU COMMON CONTROL REGISTER 2 (ADDRESS = 0X0102) ........................................................................................... 69 TABLE 68: LIU COMMON CONTROL REGISTER 3 (ADDRESS = 0X0103) ........................................................................................... 69 TABLE 69: LIU COMMON CONTROL REGISTER 4 (ADDRESS = 0X0104) .......................................................................................... 70 TABLE 70: LIU COMMON CONTROL REGISTER 5 (ADDRESS = 0X0105) ........................................................................................... 70 TABLE 71: LIU COMMON CONTROL REGISTER 6 (ADDRESS = 0X0106) ........................................................................................... 70 2.3 RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ................................................................. 71 FIGURE 3. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED ...................................................................................................................................................... 71 TABLE 72: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0202) .............................. 71 TABLE 73: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0203) ............................. 72 TABLE 74: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0206) ................................. 73 TABLE 75: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0207) ............................... 74 TABLE 76: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0209) ................ 76 TABLE 77: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X020A) ............... 77 TABLE 78: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION= 0X020B) ............... 79 TABLE 79: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 2 (ADDRESS LOCATION= 0X020D) ............... 80 TABLE 80: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X020E) ............... 81 TABLE 81: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION= 0X020F) ............... 83 TABLE 82: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0210) ...... 84 TABLE 83: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0211) ...... 84 TABLE 84: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0212) ...... 85 TABLE 85: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0213) ...... 85 TABLE 86: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0214) ...... 86 TABLE 87: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0215) ...... 86 TABLE 88: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0216) ...... 86 TABLE 89: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0217) ...... 87 TABLE 90: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION = 0X0218) .......... 87 TABLE 91: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0219) ........... 88 TABLE 92: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X021A) ........... 88 TABLE 93: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X021B) ........... 88 TABLE 94: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X021F) ................ 89 TABLE 95: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0223) ................. 89 TABLE 96: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0227) ................. 89 TABLE 97: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE IN-SYNC THRESHOLD REGISTER (ADDRESS = 0X022B) .......................... 90 TABLE 98: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - MSB (ADDRESS LOCATION= 0X022E) ......................... 90 TABLE 99: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - LSB (ADDRESS LOCATION= 0X022F) .......................... 90 TABLE 100: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X0231) 90 TABLE 101: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X0232) 91 TABLE 102: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X0233) 91 TABLE 103: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0236) ........... 92 TABLE 104: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X0237) ........... 92 TABLE 105: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X023A) ...... 92 TABLE 106: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X023B) ...... 93 TABLE 107: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X023D) 93 TABLE 108: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X023E) 94 TABLE 109: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X023F) 94 TABLE 110: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0242) ........... 95 TABLE 111: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X0243) ........... 95 TABLE 112: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0246) ...... 95 TABLE 113: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0247) ...... 96 II XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 114: RECEIVE STS-1/STS-3 TRANSPORT - FORCE SEF DEFECT CONDITION REGISTER (ADDRESS LOCATION= 0X024B) ...... 96 TABLE 115: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS LOCATION= 0X024F) ....................................................................................................................................................................... 96 TABLE 116: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 1 (ADDRESS LOCATION= 0X0252) 97 TABLE 117: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 0 (ADDRESS LOCATION= 0X0253) 98 TABLE 118: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 1 (ADDRESS LOCATION= 0X0256) 98 TABLE 119: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 0 (ADDRESS LOCATION= 0X0257) 99 TABLE 120: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X0259) 99 TABLE 121: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X025A) 99 TABLE 122: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X025B) 100 TABLE 123: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X025D) 100 TABLE 124: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X025E) . 101 TABLE 125: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X025F) 101 TABLE 126: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X0263) ...................... 102 TABLE 127: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS (IN DOWNSTREAM T1/E1S) CONTROL REGISTER (ADDRESS LOCATION= 0X026B) ..................................................................................................................................................................... 104 TABLE 128: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X026E) 105 TABLE 129: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X026F) 105 2.4 RECEIVE STS-1 POH PROCESSOR BLOCK REGISTERS ......................................................................... 105 FIGURE 4. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS-1 POH PROCESSOR BLOCK HIGHLIGHTED ............................................................................................................................................................... 106 TABLE 130: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0281) ............................................... 106 TABLE 131: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0283) ................................ 107 TABLE 132: RECEIVE STS-1 PATH - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0286) .............................................. 108 TABLE 133: RECEIVE STS-1 PATH - SONET RECEIVE POH STATUS - BYTE 0 (ADDRESS LOCATION= 0X0287) ............................ 108 TABLE 134: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 2 (ADDRESS LOCATION= 0X0289) .......... 110 TABLE 135: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 1 (ADDRESS LOCATION= 0X028A) .......... 111 TABLE 136: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 0 (ADDRESS LOCATION= 0X028B) .......... 113 TABLE 137: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 2 (ADDRESS LOCATION = 0X028D) ......... 115 TABLE 138: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 1 (ADDRESS LOCATION= 0X028E) .......... 116 TABLE 139: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 0 (ADDRESS LOCATION= 0X028F) .......... 118 TABLE 140: RECEIVE STS-1 PATH - SONET RECEIVE RDI-P REGISTER (ADDRESS LOCATION= 0X0293) ..................................... 119 TABLE 141: RECEIVE STS-1 PATH - RECEIVED PATH LABEL VALUE (ADDRESS LOCATION= 0X0296) ............................................. 120 TABLE 142: RECEIVE STS-1 PATH - EXPECTED PATH LABEL VALUE (ADDRESS LOCATION= 0X0297) ............................................ 120 TABLE 143: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0298) ...................... 120 TABLE 144: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0299) ...................... 121 TABLE 145: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029A) ...................... 121 TABLE 146: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029B) ...................... 121 TABLE 147: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X029C) ........................... 122 TABLE 148: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X029D) ........................... 122 TABLE 149: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029E) ........................... 122 TABLE 150: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029F) ............................ 123 TABLE 151: RECEIVE STS-1 PATH - RECEIVE PATH TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS LOCATION= 0X02A3) 123 TABLE 152: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 1 (ADDRESS LOCATION= 0X02A6) .................................................... 124 TABLE 153: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 0 (ADDRESS LOCATION= 0X02A7) .................................................... 125 TABLE 154: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE VALUE REGISTER (ADDRESS = 0X02B9) ................................ 125 TABLE 155: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE CONTROL REGISTER (ADDRESS = 0X02BA) ........................... 125 TABLE 156: RECEIVE STS-1 PATH - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X02BB) ......................................... 126 TABLE 157: RECEIVE STS-1 PATH - SONET RECEIVE AUTO ALARM REGISTER - BYTE 0 (ADDRESS LOCATION= 0X02C3) ............ 128 TABLE 158: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS = 0X02C4) 129 TABLE 159: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS = 0X02C5) 129 TABLE 160: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS = 0X02C6) 130 TABLE 161: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS = 0X02C7) 130 TABLE 162: RECEIVE STS-1 PATH - RECEIVE J1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D3) ................................ 130 TABLE 163: RECEIVE STS-1 PATH - RECEIVE B3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D7) ............................... 130 TABLE 164: RECEIVE STS-1 PATH - RECEIVE C2 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DB) .............................. 131 TABLE 165: RECEIVE STS-1 PATH - RECEIVE G1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DF) .............................. 131 TABLE 166: RECEIVE STS-1 PATH - RECEIVE F2 BYTE CAPTURE REGISTER (ADDRESS LOCATION=0X02E3) ................................ 131 TABLE 167: RECEIVE STS-1 PATH - RECEIVE H4 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02E7) ............................... 131 TABLE 168: RECEIVE STS-1 PATH - RECEIVE Z3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EB) ............................... 132 TABLE 169: RECEIVE STS-1 PATH - RECEIVE Z4 (K3) BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EF) ....................... 132 TABLE 170: RECEIVE STS-1 PATH - RECEIVE Z5 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02F3) ................................ 132 2.5 RECEIVE TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) III PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS 133 FIGURE 5. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE RECEIVE TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK "HIGHLIGHTED" ..................................................................................................................... 133 2.6 TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ............................................................ 133 FIGURE 6. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED ............................................................................................................................................ 134 TABLE 171: TRANSMIT STS-1/STS-3 TRANSPORT- TRANSMIT CONTROL REGISTER - BYTE 3 (ADDRESS LOCATION = 0X0700) ...... 134 TABLE 172: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION = 0X0701) ..... 135 TABLE 173: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0702) ...... 135 TABLE 174: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0703) ...... 136 TABLE 175: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A1 BYTE ERROR REGISTER (ADDRESS LOCATION = 0X0717) ......... 138 TABLE 176: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A2 BYTE ERROR REGISTER (ADDRESS LOCATION = 0X071F) ......... 138 TABLE 177: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B1 BYTE ERROR MASK REGISTER (ADDRESS LOCATION = 0X0723) 138 TABLE 178: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BYTE ERROR MASK REGISTER (ADDRESS LOCATION = 0X0727) 139 TABLE 179: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BIT ERROR MASK REGISTER (ADDRESS LOCATION= 0X072B) ... 139 TABLE 180: TRANSMIT STS-1/STS-3 TRANSPORT - K2 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X072E) ............ 140 TABLE 181: TRANSMIT STS-1/STS-3 TRANSPORT - K1 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X072F) ............ 140 TABLE 182: TRANSMIT STS-1/STS-3 TRANSPORT - RDI-L CONTROL REGISTER (ADDRESS LOCATION= 0X0733) .......................... 140 TABLE 183: TRANSMIT STS-1/STS-3 TRANSPORT - M0M1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0737) ..................... 141 TABLE 184: TRANSMIT STS-1/STS-3 TRANSPORT - S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073B) .......................... 141 TABLE 185: TRANSMIT STS-1/STS-3 TRANSPORT - F1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073F) .......................... 142 TABLE 186: TRANSMIT STS-1/STS-3 TRANSPORT - E1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0743) .......................... 142 TABLE 187: TRANSMIT STS-1/STS-3 TRANSPORT - E2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0747) .......................... 142 TABLE 188: TRANSMIT STS-1/STS-3 TRANSPORT - J0 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X074B) ........................... 143 TABLE 189: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMITTER J0 BYTE CONTROL REGISTER (ADDRESS LOCATION= 0X074F) . 143 2.7 TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ............................................................ 145 FIGURE 7. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK HIGHLIGHTED ............................................................................................................................................ 145 TABLE 190: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION = 0X0781) ............... 145 TABLE 191: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0782) ............... 146 TABLE 192: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0783) ................ 147 TABLE 193: TRANSMIT STS-1/STS-3 PATH - TRANSMITTER J1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0793) ................ 148 TABLE 194: TRANSMIT STS-1/STS-3 PATH - TRANSMIT B3 BYTE ERROR MASK REGISTER (ADDRESS LOCATION= 0X0797) .......... 148 TABLE 195: TRANSMIT STS-1/STS-3 PATH - TRANSMIT C2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079B) .................... 149 TABLE 196: TRANSMIT STS-1/STS-3 PATH - TRANSMIT G1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079F) .................... 149 TABLE 197: TRANSMIT STS-1/STS-3 PATH - TRANSMIT F2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A3) ..................... 149 TABLE 198: TRANSMIT STS-1/STS-3 PATH - TRANSMIT H4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A7) .................... 150 TABLE 199: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z3 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07AB) .................... 150 TABLE 200: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0XN9AF) .................... 150 TABLE 201: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z5 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07B3) ..................... 151 TABLE 202: TRANSMIT STS-1/STS-3 PATH - TRANSMIT PATH CONTROL REGISTER (ADDRESS LOCATION= 0X07B7) ..................... 151 TABLE 203: TRANSMIT STS-1/STS-3 PATH - SONET PATH J1 CONTROL REGISTER (ADDRESS LOCATION= 0X07BB) .................. 153 TABLE 204: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H1 POINTER REGISTER (ADDRESS LOCATION= 0X07BF) ........ 153 TABLE 205: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H2 POINTER REGISTER (ADDRESS LOCATION= 0X07C3) ........ 154 TABLE 206: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07C6) 154 TABLE 207: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07C7) 154 TABLE 208: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION= 0X07C9) ..................... 155 TABLE 209: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07CA) ..................... 155 TABLE 210: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07CB) ..................... 156 TABLE 211: TRANSMIT STS-1/STS-3 PATH - SERIAL PORT CONTROL REGISTER (ADDRESS LOCATION= 0X07CF) ......................... 157 TABLE 212: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D0) ........................................................................................................................................................... 157 TABLE 213: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07D1) ........................................................................................................................................................... 158 TABLE 214: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D2) ..................................................................................................................................................................... 158 TABLE 215: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D3) ..................................................................................................................................................................... 158 2.8 TRANSMIT TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY)............................................................................................................................................................ 158 FIGURE 8. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT TUG-3 MAPPER/VC4 POH PROCESSOR BLOCK "HIGHLIGHTED" .................................................................................................................. 159 2.9 GLOBAL VT MAPPER BLOCK CONTROL REGISTERS .............................................................................. 159 TABLE 216: GLOBAL CONTROL - VT-MAPPER BLOCK - VT MAPPER BLOCK CONTROL REGISTER (ADDRESS = 0X0C03) ................. 159 IV XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 9. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WITH THE VT-MAPPER SONET/SDH LOOP-BACK PATH DEPICTED ........................................................................................................................................................... 161 TABLE 217: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0C0E) ......... 161 TABLE 218: GLOBAL VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0C0F) ........................... 162 TABLE 219: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 1 (ADDRESS = 0X0C12) ............... 163 TABLE 220: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 0 (ADDRESS = 0X0C13) ............... 165 TABLE 221: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - UPPER BYTE (ADDRESS = 0X0C16) 166 TABLE 222: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - LOWER BYTE (ADDRESS = 0X0C17) 167 TABLE 223: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1A) ................... 167 TABLE 224: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1B) ................... 168 TABLE 225: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1E) ..................... 170 TABLE 226: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1F) ..................... 171 2.10 DS3 MAPPER CONTROL REGISTERS........................................................................................................ 172 TABLE 227: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D02) .............................................. 172 TABLE 228: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D03) .............................................. 173 TABLE 229: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D06) .................................. 173 TABLE 230: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D07) .................................. 174 TABLE 231: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D0B) ................... 175 TABLE 232: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0D0E) ................... 176 TABLE 233: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 2 (ADDRESS = 0X0D21) ........................... 176 TABLE 234: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 1 (ADDRESS = 0X0D22) ........................... 177 TABLE 235: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D23) ........................... 177 TABLE 236: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0D26) .............. 177 TABLE 237: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0D27) .............. 177 2.11 DS3 FRAMER AND M13 MUX BLOCK REGISTERS ................................................................................... 177 FIGURE 10. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE FUNCTIONAL BLOCKS (WHICH ARE CONTROLLED/MONITORED VIA THE DS3 FRAMER AND M13 MUX BLOCK REGISTERS) HIGHLIGHTED. ..................................... 178 TABLE 238: DS3 FRAMER BLOCK OPERATING MODE REGISTER (ADDRESS = 0X0E00) ................................................................. 178 TABLE 239: DS3 FRAMER BLOCK - I/O CONTROL REGISTER (ADDRESS = 0X0E01) ...................................................................... 179 TABLE 240: DS3 FRAMER BLOCK - BLOCK INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E04) .................................................. 180 TABLE 241: DS3 FRAMER BLOCK - BLOCK INTERRUPT STATUS REGISTER (ADDRESS = 0X0E05) .................................................. 181 TABLE 242: DS3 FRAMER BLOCK - M23 CONFIGURATION REGISTER (ADDRESS = 0X0E07) .......................................................... 182 FIGURE 11. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN CONFIGURED TO OPERATE IN THE M13 LOCAL LOOP- BACK MODE .............................................................................................................. 183 TABLE 243: DS3 FRAMER BLOCK - M23 TRANSMIT DS2 AIS COMMAND REGISTER (ADDRESS = 0X0E08) .................................... 184 FIGURE 12. AN ILLUSTRATION OF THE XRT86SH328, WHENEVER THE M12 MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR TOWARDS BOTH THE M23 MUX AND THE TRANSMIT DS3 FRAMER BLOCK .......................................................... 184 TABLE 244: DS3 FRAMER BLOCK - M23 - DS2 LOOP-BACK REQUEST REGISTER (ADDRESS = 0X0E09) ........................................ 185 TABLE 245: DS3 FRAMER BLOCK - M23 LOOP-BACK ACTIVATION REGISTER (ADDRESS = 0X0E0A) .............................................. 186 FIGURE 13. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN DS2 CHANNEL HAS BEEN CONFIGURED TO OPERATE IN THE REMOTE DS2 LOOP-BACK MODE .............................................................................. 186 TABLE 246: DS3 FRAMER BLOCK - M23 MUX FORCE RECEIVE DS2 AIS COMMAND REGISTERS (ADDRESS = 0X0E0B) ............... 187 FIGURE 14. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE M23 DE-MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR IN THE EGRESS DIRECTION OF DS2 CHANNEL 0 .................................. 188 TABLE 247: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER (ADDRESS = 0X0E0C) .................................................. 189 TABLE 248: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER # 2 (ADDRESS = 0X0E0E) ............................................. 189 TABLE 249: DS3 FRAMER BLOCK - RECEIVE DS3 CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E10) ............................ 190 TABLE 250: DS3 FRAMER BLOCK - RECEIVE DS3 STATUS REGISTER (ADDRESS = 0X0E11) ......................................................... 191 TABLE 251: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E12) ....................................... 192 TABLE 252: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT STATUS ........................................ REGISTER (ADDRESS = 0X0E13) 194 TABLE 253: DS3 FRAMER BLOCK - RECEIVE DS3 SYNC DETECT REGISTER (ADDRESS = 0X0E14) ............................................... 195 TABLE 254: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC REGISTER (ADDRESS = 0X0E16) .......................................................... 195 TABLE 255: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC INTERRUPT ENABLE/STATUS REGISTER (ADDRESS = 0X0E17) ............... 196 TABLE 256: DS3 FRAMER BLOCK - RECEIVE LAPD CONTROL REGISTER (ADDRESS = 0X0E18) .................................................... 197 TABLE 257: DS3 FRAMER BLOCK - RECEIVE DS3 LAPD STATUS REGISTER (ADDRESS = 0X0E19) .............................................. 198 TABLE 258: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E1A) .......................... 199 TABLE 259: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E1B) .......................... 200 TABLE 260: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E1C) ......................... 200 TABLE 261: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E1D) .......................... 200 TABLE 262: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E1E) .......................... 201 TABLE 263: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E1F) ........................... 201 TABLE 264: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 7 (ADDRESS = 0X0E20) ........................... 201 TABLE 265: DS3 FRAMER BLOCK - M12 DE-MUX FORCE DS1/E1 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E21) ...... 201 FIGURE 15. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN M12 DE-MUX BLOCK HAS V PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BEEN CONFIGURED TO TRANSMIT THE DS1/E1 AIS INDICATOR (WITHIN A GIVEN DS1/E1 SIGNAL) IN THE EGRESS DIRECTION 202 TABLE 266: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E22) .............................................. 203 TABLE 267: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E23) .............................................. 203 TABLE 268: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E24) .............................................. 203 TABLE 269: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E25) .............................................. 204 TABLE 270: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E26) .............................................. 204 TABLE 271: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E27) .............................................. 204 TABLE 272: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 1 (ADDRESS = 0X0E28) ............................................................ 205 FIGURE 16. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN CONFIGURED TO OPERATE IN THE M12 REMOTE LOOP-BACK MODE ...................................................................................................................... 205 TABLE 273: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 2 (ADDRESS = 0X0E29) ............................................................ 206 TABLE 274: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 3 (ADDRESS = 0X0E2A) ............................................................ 206 TABLE 275: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 4 (ADDRESS = 0X0E2B) ............................................................ 207 TABLE 276: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 5 (ADDRESS = 0X0E2C) ............................................................ 207 TABLE 277: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 6 (ADDRESS = 0X0E2D) ............................................................ 207 TABLE 278: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 7 (ADDRESS = 0X0E2E) ............................................................ 207 TABLE 279: DS3 FRAMER BLOCK - TRANSMIT DS3 CONFIGURATION REGISTER (ADDRESS = 0X0E30) .......................................... 208 TABLE 280: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E31) ............... 209 TABLE 281: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC REGISTER (ADDRESS = 0X0E32) ......................................................... 210 TABLE 282: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD CONFIGURATION REGISTER (ADDRESS = 0X0E33) ................................ 211 TABLE 283: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD STATUS/INTERRUPT REGISTER (ADDRESS = 0X0E34) ........................... 212 TABLE 284: DS3 FRAMER BLOCK - TRANSMIT DS3 M-BIT MASK REGISTER (ADDRESS = 0X0E35) ................................................ 212 TABLE 285: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTERS # 1 (ADDRESS = 0X0E36) ......................................... 213 TABLE 286: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 2 (ADDRESS = 0X0E37) ........................................... 214 TABLE 287: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 3 (ADDRESS = 0X0E38) ........................................... 215 TABLE 288: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 4 (ADDRESS = 0X0E39) ........................................... 215 TABLE 289: DS3 FRAMER BLOCK - M12 DS2 # 1 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3A) .............................. 216 TABLE 290: DS3 FRAMER BLOCK - M12 DS2 # 2 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3B) .............................. 217 TABLE 291: DS3 FRAMER BLOCK - M12 DS2 # 3 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3C) .............................. 218 TABLE 292: DS3 FRAMER BLOCK - M12 DS2 # 4 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3D) .............................. 218 TABLE 293: DS3 FRAMER BLOCK - M12 DS2 # 5 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3E) .............................. 218 TABLE 294: DS3 FRAMER BLOCK - M12 DS2 # 6 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3F) .............................. 219 TABLE 295: DS3 FRAMER BLOCK - M12 DS2 # 7 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E40) ............................... 219 TABLE 296: DS3 FRAMER BLOCK - TRANSMIT DS3 PATTERN REGISTER (ADDRESS = 0X0E4C) .................................................... 219 TABLE 297: DS3 FRAMER BLOCK - AUTO T1/E1 AIS UPON DS3 DEFECT CONDITION REGISTER (ADDRESS = 0X0E4D) ................ 220 TABLE 298: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E4E) ........ 221 TABLE 299: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E4F) ......... 222 TABLE 300: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E50) . 222 TABLE 301: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E51) .. 222 TABLE 302: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E52) ......................... 222 TABLE 303: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E53) .......................... 223 TABLE 304: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E54) .................................... 223 TABLE 305: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E55) ..................................... 223 TABLE 306: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E56) .................................... 224 TABLE 307: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E57) ..................................... 224 TABLE 308: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E58) ............................................. 224 TABLE 309: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E59) .............................................. 224 TABLE 310: DS3 FRAMER BLOCK - PMON DS2 # 1 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5A) ..................... 225 TABLE 311: DS3 FRAMER BLOCK - PMON DS2 # 2 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5B) ..................... 225 TABLE 312: DS3 FRAMER BLOCK - PMON DS2 # 3 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5C) ..................... 225 TABLE 313: DS3 FRAMER BLOCK - PMON DS2 # 4 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5D) ..................... 225 TABLE 314: DS3 FRAMER BLOCK - PMON DS2 # 5 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5E) ..................... 226 TABLE 315: DS3 FRAMER BLOCK - PMON DS2 # 6 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5F) ..................... 226 TABLE 316: DS3 FRAMER BLOCK - PMON DS2 # 7 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E60) ...................... 226 TABLE 317: DS3 FRAMER BLOCK - PMON G.747 # 1 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E61) ...................... 226 TABLE 318: DS3 FRAMER BLOCK - PMON G.747 # 2 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E62) ...................... 226 TABLE 319: DS3 FRAMER BLOCK - PMON G.747 # 3 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E63) ...................... 227 TABLE 320: DS3 FRAMER BLOCK - PMON G.747 # 4 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E64) ...................... 227 TABLE 321: DS3 FRAMER BLOCK - PMON G.747 # 5 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E65) ...................... 227 TABLE 322: DS3 FRAMER BLOCK - PMON G.747 # 6 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E66) ...................... 227 TABLE 323: DS3 FRAMER BLOCK - PMON G.747 # 7 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E67) ...................... 227 TABLE 324: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E68) ........................................ 228 TABLE 325: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E69) ......................................... 228 TABLE 326: DS3 FRAMER BLOCK - ONE SECOND ERROR STATUS REGISTER (ADDRESS = 0X0E6D) ............................................. 228 TABLE 327: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E6E) ........................... 229 VI XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 328: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E6F) ............................ 229 TABLE 329: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E70) .............. 229 TABLE 330: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E71) ............... 230 TABLE 331: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E72) ............ 230 TABLE 332: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E73) ............. 230 TABLE 333: DS3 FRAMER BLOCK - TRANSMIT LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E83) ............................................. 231 TABLE 334: DS3 FRAMER BLOCK - RECEIVE LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E84) ............................................... 231 TABLE 335: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E90) ..... 231 TABLE 336: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT STATUS REGISTER (ADDRESS = 0X0E91) ..... 232 TABLE 337: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST STATUS REGISTER (ADDRESS = 0X0E92) ....................... 233 TABLE 338: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 1 (ADDRESS = 0X0E93) ................. 234 TABLE 339: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 1 (ADDRESS = 0X0E94) ............................................. 235 TABLE 340: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 2 (ADDRESS = 0X0E95) ................. 235 TABLE 341: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 2 (ADDRESS = 0X0E96) ............................................. 236 TABLE 342: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 3 (ADDRESS = 0X0E97) ................. 236 TABLE 343: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 3 (ADDRESS = 0X0E98) ............................................. 236 TABLE 344: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 4 (ADDRESS = 0X0E99) ................. 237 TABLE 345: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 4 (ADDRESS = 0X0E9A) ............................................. 237 TABLE 346: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 5 (ADDRESS = 0X0E9B) ................. 237 TABLE 347: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 5 (ADDRESS = 0X0E9C) ............................................. 238 TABLE 348: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 6 (ADDRESS = 0X0E9D) ................ 238 TABLE 349: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 6 (ADDRESS = 0X0E9E) ............................................. 238 TABLE 350: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 7 (ADDRESS = 0X0E9F) ................. 239 TABLE 351: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 7 (ADDRESS = 0X0EA0) ............................................. 239 TABLE 352: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA1) ................................. 239 TABLE 353: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA2) ................................. 241 TABLE 354: DS3 FRAMER BLOCK - DS2 # 1 FRAMER STATUS REGISTER (ADDRESS = 0X0EA3) ................................................... 242 TABLE 355: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA4) ................................. 243 TABLE 356: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA5) ................................. 243 TABLE 357: DS3 FRAMER BLOCK - DS2 # 2 FRAMER STATUS REGISTER (ADDRESS = 0X0EA6) ................................................... 243 TABLE 358: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA7) ................................. 244 TABLE 359: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA8) ................................. 244 TABLE 360: DS3 FRAMER BLOCK - DS2 # 3 FRAMER STATUS REGISTER (ADDRESS = 0X0EA9) ................................................... 244 TABLE 361: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAA) ................................. 245 TABLE 362: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAB) ................................. 245 TABLE 363: DS3 FRAMER BLOCK - DS2 # 4 FRAMER STATUS REGISTER (ADDRESS = 0X0EAC) .................................................. 245 TABLE 364: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAD) ................................. 246 TABLE 365: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAE) ................................. 246 TABLE 366: DS3 FRAMER BLOCK - DS2 # 5 FRAMER STATUS REGISTER (ADDRESS = 0X0EAF) ................................................... 246 TABLE 367: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB0) ................................. 247 TABLE 368: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB1) ................................. 247 TABLE 369: DS3 FRAMER BLOCK - DS2 # 6 FRAMER STATUS REGISTER (ADDRESS = 0X0EB2) ................................................... 247 TABLE 370: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB3) ................................. 248 TABLE 371: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB4) ................................. 248 TABLE 372: DS3 FRAMER BLOCK - DS2 # 7 FRAMER STATUS REGISTER (ADDRESS = 0X0EB5) ................................................... 248 TABLE 373: DS3 FRAMER BLOCK - M13 DE-MUX REGISTER (ADDRESS = 0X0EB8) ..................................................................... 249 2.12 T1/E1 LIU CHANNEL CONTROL REGISTERS ............................................................................................ 249 TABLE 374: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN000) ..................................................................................... 249 TABLE 375: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN001) ...................................................................................... 250 TABLE 376: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN002) ...................................................................................... 251 TABLE 377: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN003) ...................................................................................... 252 TABLE 378: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN004) ...................................................................................... 253 TABLE 379: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN005) ...................................................................................... 253 TABLE 380: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN006) ...................................................................................... 254 TABLE 381: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN007) ...................................................................................... 255 TABLE 382: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN008) ...................................................................................... 256 TABLE 383: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN009) ...................................................................................... 256 TABLE 384: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00A) ...................................................................................... 256 TABLE 385: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00B) ...................................................................................... 257 TABLE 386: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00C) ...................................................................................... 257 TABLE 387: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00D) ...................................................................................... 257 TABLE 388: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00E) ...................................................................................... 258 TABLE 389: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00F) ...................................................................................... 258 TABLE 390: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN010) ...................................................................................... 258 TABLE 391: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN011) ...................................................................................... 259 2.13 DS1/E1 FRAMER BLOCK REGISTERS - DS1 APPLICATIONS ................................................................. 259 VII PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS FIGURE 17. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT/RECEIVE DS1/E1 FRAMER BLOCKS HIGHLIGHTED ..................................................................................................................................... 259 TABLE 392: MEMORY MAP - T1/E1 FRAMER BLOCK ..................................................................................................................... 260 FIGURE 18. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE WITH BOTH THE INGRESS AND EGRESS DIRECTION T1/E1 FRAMER BLOCKS (OF A GIVEN T1/E1 CHANNEL) HIGHLIGHTED .............................................................. 261 TABLE 393: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - VT-MAPPER (WITH T1/E1 FRAMING) MODE APPLICATIONS ............................................................................................................................................................. 261 TABLE 394: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - M13 MUX (WITH T1/E1 FRAMING) MODE APPLICATIONS ............................................................................................................................................................. 262 TABLE 395: T1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 263 TABLE 396: T1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ......................................................................................................................................................................... 264 TABLE 397: T1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 265 TABLE 398: T1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 266 TABLE 399: T1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ......................................................................................................................................................................... 268 TABLE 400: T1 FRAMER BLOCK - TRANSMIT DATA LINK SELECT REGISTER (ADDRESS = 0XN10A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................................... 268 TABLE 401: T1 FRAMER BLOCK - FRAMING CONTROL REGISTER (ADDRESS = 0XN10B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 270 TABLE 402: T1 FRAMER BLOCK - RECEIVE SIGNALING & DATA LINK SELECT REGISTER (ADDRESS = 0XN10C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................. 270 TABLE 403: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 0 (ADDRESS = 0XN10D, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ............................................................................................................................................................ 272 TABLE 404: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 1 (ADDRESS = 0XN10E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ............................................................................................................................................................ 272 TABLE 405: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 2 (ADDRESS = 0XN10F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ............................................................................................................................................................ 272 TABLE 406: T1 FRAMER BLOCK - RECEIVE EXTRA-BITS REGISTER (ADDRESS = 0XN112, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 273 TABLE 407: T1 FRAMER BLOCK - DATA LINK CONTROL REGISTER (ADDRESS = 0XN113, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 273 TABLE 408: T1 FRAMER BLOCK - TRANSMIT DATA LINK CONTROL REGISTER (ADDRESS = 0XN114, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................................... 274 TABLE 409: T1 FRAMER BLOCK - RECEIVE DATA LINK CONTROL REGISTER (ADDRESS = 0XN115, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................................... 275 TABLE 410: T1 FRAMER BLOCK - CUSTOMER INSTALLATION ALARM GENERATION REGISTERS (ADDRESS = 0XN11C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................................................................ 275 TABLE 411: T1 FRAMER BLOCK - DS1 TEST REGISTER - 2 (ADDRESS = 0XN121, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 276 TABLE 412: T1 FRAMER BLOCK - DS1 TEST REGISTER - 1 (ADDRESS = 0XN123, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 277 TABLE 413: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 0(ADDRESS = 0XN124, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ............................................................................................................................................................ 278 TABLE 414: T1 FRAMER BLOCK - TRANSMIT LOOP-BACK CODE REGISTER (ADDRESS = 0XN125, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................................... 279 TABLE 415: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 0 (ADDRESS = 0XN126, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................................... 280 TABLE 416: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 0 (ADDRESS = 0XN127, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................................................................................................... 281 TABLE 417: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 1 (ADDRESS = 0XN12A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................. 281 TABLE 418: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 1 (ADDRESS = 0XN12B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................................... 282 TABLE 419: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 1 (ADDRESS = 0XN12C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................................................................................................... 283 TABLE 420: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 2 (ADDRESS = 0XN12D, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................................. 284 TABLE 421: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 2 (ADDRESS = 0XN12E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................................... 285 TABLE 422: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 2 (ADDRESS = 0XN12F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ................................................................................................................... 285 TABLE 423: T1 FRAMER BLOCK - TRANSMIT CHANNEL CONTROL REGISTER - T1 TIME SLOT # 0 (ADDRESS = 0XN300, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .................................................................................................................................... 286 TABLE 424: T1 FRAMER BLOCK - LAPD BUFFER 0 CONTROL REGISTER (ADDRESS = 0XN600 - 0XN640, WHERE N RANGES IN VALUE FROM VIII XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 0X01 TO 0X38) ............................................................................................................................................................ 287 TABLE 425: T1 FRAMER BLOCK - LAPD BUFFER 1 CONTROL REGISTER (ADDRESS = 0XN700 - 0XN740, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ............................................................................................................................................................ 287 TABLE 426: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER -CODE 0 (ADDRESS = 0XNB0A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 288 TABLE 427: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 0 (ADDRESS = 0XNB0B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 289 TABLE 428: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER - CODE 1 (ADDRESS = 0XNB14, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 290 TABLE 429: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 1 (ADDRESS = 0XNB15, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ....................................................................................................... 291 TABLE 430: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER - CODE 2 (ADDRESS = 0XNB1A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 292 TABLE 431: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 2 (ADDRESS = 0XNB1B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ........................................................................................ 293 2.14 DS1/E1 FRAMER BLOCK REGISTERS - E1 APPLICATIONS ................................................................... 294 TABLE 432: E1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 294 TABLE 433: E1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .......................................................................................................................................................................... 295 TABLE 434: E1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 296 TABLE 435: E1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) 298 TABLE 436: E1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) .......................................................................................................................................................................... 299 2.15 CHANNEL CONTROL-VT MAPPER BLOCK REGISTERS.......................................................................... 300 FIGURE 19. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE VT-MAPPER BLOCK HIGHLIGHTED 301 TABLE 437: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION DS1/E1 INSERTION CONTROL REGISTER - 2 (ADDRESS = 0XND41) .................................................................................................................................................................... 301 TABLE 438: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL REGISTER - 1 (ADDRESS = 0XND42, WHERE N RANGES FROM 0X01 TO 0X1C) ...................................................................................................... 302 TABLE 439: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL REGISTER - 0 (ADDRESS = 0XND43 , WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 303 FIGURE 20. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WHENEVER THE VT-MAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) HAS BEEN CONFIGURED TO TRANSMIT THE AIS-V INDICATOR TOWARDS DOWN-STREAM CIRCUITRY 304 TABLE 440: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 3 (ADDRESS = 0XND44, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 306 TABLE 441: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 2 (ADDRESS = 0XND45, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 306 TABLE 442: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 1 (ADDRESS = 0XND46, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 307 TABLE 443: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYT E 0 (ADDRESS = 0XND47, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ..................................................................................... 307 FIGURE 21. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE VT-DE-MAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) OVERWRITES THE CONTENTS OF A DE-MAPPED DS1/E1 SIGNAL WITH THE DS1/E1 AIS PATTERN ........................................................................................................................................................................... 308 TABLE 444: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER - BYTE 1 (ADDRESS = 0XND4A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 310 TABLE 445: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER - BYTE 0 (ADDRESS = 0XND4B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 311 TABLE 446: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER - BYTE 1 (ADDRESS = 0XND4E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 311 TABLE 447: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER - BYTE 0 (ADDRESS = 0XND4F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................... 312 TABLE 448: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - RECEIVE APS REGISTER - BYTE 0 (ADDRESS = 0XND53, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 312 TABLE 449: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS REGISTER - BYTE 2 (ADDRESS = 0XND56, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 312 TABLE 450: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS/K4 REGISTER (ADDRESS = 0XND57, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ................................................................................................................... 313 TABLE 451: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - J2 BYTE STATUS REGISTER (ADDRESS = 0XND63, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ................................................................................................................... 314 TABLE 452: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER - BYTE 0 (ADDRESS = IX PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS 0XND64, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 314 TABLE 453: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER - BYTE 0 (ADDRESS = 0XND65, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 315 TABLE 454: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT STATUS REGISTER (ADDRESS = 0XND67, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................................................. 317 TABLE 455: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND68, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................................................. 318 TABLE 456: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND69, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 318 TABLE 457: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND6B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 320 TABLE 458: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - VT-PATH TRACE BUFFER CONTROL REGISTER (ADDRESS = 0XND71, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ................................................................................... 321 TABLE 459: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER - BYTE 1 (ADDRESS = 0XND72, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 322 TABLE 460: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER - BYTE 0 (ADDRESS = 0XND73, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ........................................................................................ 323 TABLE 461: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT J2 BYTE VALUE REGISTER (ADDRESS = 0XND76, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 324 TABLE 462: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT N2 BYTE VALUE REGISTER (ADDRESS = 0XND77, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ....................................................................................................... 324 TABLE 463: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT VT-PATH TRACE MESSAGE CONTROL REGISTER (ADDRESS = 0XND79, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................... 325 TABLE 464: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 3 (ADDRESS = 0XND84, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 326 TABLE 465: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 2 (ADDRESS = 0XND85, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 326 TABLE 466: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 1 (ADDRESS = 0XND86, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 327 TABLE 467: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 0 (ADDRESS = 0XND87, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) .................................................................................... 328 REVISIONS................................................................................................................................................ 329 X PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 1.0 REGISTER MAP & DESCRIPTION FOR THE XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX AND VT-MAPPER IC - SONET APPLICATIONS 1.1 REGISTER MAP OF THE XRT86SH328 TABLE 2: OPERATION CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0000 Operation Control Register - Byte 3 R/W 0x00 0x0001 Operation Control Register - Byte 2 R/W 0x00 0x0002 Reserved 0x0003 Operation Control Register - Byte 0 R/W 0x00 0x0004 Device ID Register R/O 0x50 0x0005 Revision ID Register R/O 0x01 RUR 0x00 R/W 0x00 0x0006 - 0x000A Reserved 0x000B Operation Interrupt Status Register - Byte 0 0x000C - 0x000E Reserved 0x000F 0x0010 - 0x0011 Operation Interrupt Enable Register - Byte 0 Reserved 0x0012 Operation Block - Interrupt Status Register - Byte 1 R/O 0x00 0x0013 Operation Block - Interrupt Status Register - Byte 0 R/O 0x00 0x0014 - 0x0015 Reserved 0x0016 Operation Block - Interrupt Enable Register - Byte 1 R/W 0x00 0x0017 Operation Block - Interrupt Enable Register - Byte 0 R/W 0x00 R/W 0x00 R/W 0x00 0x0018 - 0x001A Reserved 0x001B Operation Block - Mode Control Register - Byte 0 0x001C - 0x001E Reserved 0x001F Operation Block - Loop-back Control Register - Byte 0 0x0020 - 0x0033 Reserved 0x0034 Operation Block - Telecom Bus Control Register - Byte 3 R/W 0x00 0x0035 Operation Block - Telecom Bus Control Register - Byte 2 R/W 0x00 0x0036 Operation Block - Telecom Bus Control Register - Byte 1 R/W 0x00 0x0037 Operation Block - Telecom Bus Control Register - Byte 0 R/W 0x00 RUR & R/W 0x00 R/W 0x00 0x0038 - 0x003B Reserved 0x003C Operation Block - Interface Control Register 0x003D - 0x0046 Reserved 0x0047 Operation Block - General Purpose Input/Output Register - Byte 0 4 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 2: OPERATION CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE RW 0x00 0x0048 - 0x004A Reserved 0x004B Operation Block - General Purpose Input/Output Direction Register Byte 0 0x004C - 0x004E Reserved 0x004F Operation Block - Operation I/O Control Register R/W 0x00 0x0050 Operation Block - Channel Interrupt Indication Register - VT Slot[27:24] R/O 0x00 0x0051 Operation Block - Channel Interrupt Indicator Register - VT Slot[23:16] R/O 0x00 0x0052 Operation Block - Channel Interrupt Indicator Register - VT Slot[15:8] R/O 0x00 0x0053 Operation Block - Channel Interrupt Indicator Register - VT Slot[7:0] R/O 0x00 0x0054 Operation Block - Channel Interrupt Indicator Register - M13 Slot[27:24] R/O 0x00 0x0055 Operation Block - Channel Interrupt Indicator Register - M13 Slot[23:16] R/O 0x00 0x0056 Operation Block - Channel Interrupt Indicator Register - M13 Slot[15:8] R/O 0x00 0x0057 Operation Block - Channel Interrupt Indicator Register - M13 Slot[7:0] R/O 0x00 0x0058 Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU Slot[27:24] R/O 0x00 0x0059 Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU Slot[23:16] R/O 0x00 0x005A Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU Slot[15:8] R/O 0x00 0x005B Operation Block - Channel Interrupt Indicator Register - DS1E1 LIU Slot[7:0] R/O 0x00 0x005C Operation Block - Channel Interrupt Indicator Register - VT-Mapper Slot[27:24] R/O 0x00 0x005D Operation Block - Channel Interrupt Indicator Register - VT-Mapper Slot[23:16] R/O 0x00 0x005E Channel Interrupt Indication Register - VT-Mapper Slot[15:8] R/O 0x00 0x005F Channel Interrupt Indication Register - VT-Mapper Slot[7:0] R/O 0x00 TYPE DEFAULT VALUE 0x0060 - 0x00FF Reserved TABLE 3: LIU COMMON CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME 0x0100 LIU Common Control Register - 0 R/W 0x00 0x0101 LIU Common Control Register - 1 R/W 0x00 0x0102 LIU Common Control Register - 2 R/W 0x00 5 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 3: LIU COMMON CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0103 LIU Common Control Register - Global Channel Interrupt Status Register Channels [6:0] RUR 0x00 0x0104 LIU Common Control Register - Global Channel Interrupt Status Register Channels [13:7] RUR 0x00 0x0105 LIU Common Control Register - Global Channel Interrupt Status Register Channels [20:14] RUR 0x00 0x0106 LIU Common Control Register - Global Channel Interrupt Status Register Channels [27:21] RUR 0x00 0x0107 - 0x01FF Reserved TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION 0x0200 - 0x0201 REGISTER NAME TYPE DEFAULT VALUE Reserved 0x0202 Receive STS-1/STS-3 Transport - Control Register - Byte 1 R/W 0x00 0x0203 Receive STS-1/STS-3 Transport - Control Register - Byte 0 R/W 0x00 Reserved R/O 0x00 0x0206 Receive STS-1/STS-3 Transport - Status Register - Byte 1 R/O 0x00 0x0207 Receive STS-1/STS-3 Transport - Status Register - Byte 0 R/O 0x00 0x0208 Reserved 0x0209 Receive STS-1/STS-3 Transport - Interrupt Status Register - Byte 2 RUR 0x00 0x020A Receive STS-1/STS-3 Transport - Interrupt Status Register - Byte 1 RUR 0x00 0x020B Receive STS-1/STS-3 Transport - Interrupt Status Register - Byte 0 RUR 0x00 0x020C Reserved 0x020D Receive STS-1/STS-3 Transport - Interrupt Enable Register - Byte 2 R/W 0x00 0x020E Receive STS-1/STS-3 Transport - Interrupt Enable Register - Byte 1 R/W 0x00 0x020F Receive STS-1/STS-3 Transport - Interrupt Enable Register - Byte 0 R/W 0x00 0x0210 Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 3 RUR 0x00 0x0211 Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 2 RUR 0x00 0x0212 Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 1 RUR 0x00 0x0213 Receive STS-1/STS-3 Transport - Receive B1 Byte Error Count Register Byte 0 RUR 0x00 0x0204 - 0x0205 6 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0214 Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 3 RUR 0x00 0x0215 Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 2 RUR 0x00 0x0216 Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 1 RUR 0x00 0x0217 Receive STS-1/STS-3 Transport - Receive B2 Byte Error Count Register Byte 0 RUR 0x00 0x0218 Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 3 RUR 0x00 0x0219 Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 2 RUR 0x00 0x021A Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 1 RUR 0x00 0x021B Receive STS-1/STS-3 Transport - Receive REI-L Event Count Register Byte 0 RUR 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/W 0x00 0x021C - 0x021E Reserved 0x021F 0x0220 - 0x0222 0x0223 0x0224 -0x0226 0x0227 Receive STS-1/STS-3 Transport - Receive K1 Byte Value Register Reserved Receive STS-1/STS-3 Transport - Receive K2 Byte Value Register Reserved Receive STS-1/STS-3 Transport - Receive S1 Byte Value Register 0x0228 - 0x022A Reserved 0x022B Receive STS-1/STS-3 Transport - Receive In-Sync Threshold Register 0x022C - 0x022D Reserved 0x022E Receive STS-1/STS-3 Transport - Receive LOS Threshold Register - MSB R/W 0x00 0x022F Receive STS-1/STS-3 Transport - Receive LOS Threshold Register - LSB R/W 0x00 0x0230 Reserved 0x0231 Receive STS-1/STS-3 Transport - Receive SF Defect Declare Monitor Interval Register - Byte 2 R/W 0x00 0x0232 Receive STS-1/STS-3 Transport - Receive SF Defect Declare Monitor Interval Register - Byte 1 R/W 0x00 0x0233 Receive STS-1/STS-3 Transport - Receive SF Defect Declare Monitor Interval Register - Byte 0 R/W 0x00 R/W 0x00 0x0234 - 0x0235 0x0236 Reserved Receive STS-1/STS-3 Transport - Receive SF Defect Set Threshold Register - Byte 1 7 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0237 Receive STS-1/STS-3 Transport - Receive SF Defect Set Threshold Register - Byte 0 R/W 0x00 0x0238 - 0x0239 Reserved 0x023A Receive STS-1/STS-3 Transport - Receive SF Defect Clear Threshold Register - Byte 1 R/W 0x00 0x023B Receive STS-1/STS-3 Transport - Receive SF Defect Clear Threshold Register - Byte 0 R/W 0x00 0x023C Reserved 0x023D Receive STS-1/STS-3 Transport - Receive SD Defect Declare Monitor Interval - Byte 2 R/W 0x00 0x023E Receive STS-1/STS-3 Transport - Receive SD Defect Declare Monitor Interval - Byte 1 R/W 0x00 0x023F Receive STS-1/STS-3 Transport - Receive SD Defect Declare Monitor Interval - Byte 0 R/W 0x00 0x0240 - 0x0241 Reserved 0x0242 Receive STS-1/STS-3 Transport - Receive SD Defect Set Threshold Register - Byte 1 R/W 0x00 0x0243 Receive STS-1/STS-3 Transport - Receive SD Defect Set Threshold Register - Byte 0 R/W 0x00 0x0244 - 0x0245 Reserved 0x0246 Receive STS-1/STS-3 Transport - Receive SD Defect Clear Threshold Register - Byte 1 R/W 0x00 0x0247 Receive STS-1/STS-3 Transport - Receive SD Defect Clear Threshold Register - Byte 0 R/W 0x00 R/W 0x00 R/W 0x00 0x0248 - 0x024A Reserved 0x024B 0x024C -0x024E 0x024F 0x0250 - 0x0251 Receive STS-1/STS-3 Transport - SEF Force Register Reserved Receive STS-1/STS-3 Transport - Receive J0 Byte/Section Trace Message Control Register Reserved 0x0252 Receive STS-1/STS-3 Transport - Receive SD Defect Error Burst Tolerance Register - Byte 1 R/W 0x00 0x0253 Receive STS-1/STS-3 Transport - Receive SD Defect Error Burst Tolerance Register - Byte 0 R/W 0x00 R/W 0x00 0x0254 - 0x0255 0x0256 Reserved Receive STS-1/STS-3 Transport - Receive SF Defect Error Burst Tolerance Register - Byte 1 8 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE R/W 0x00 0x0257 Receive STS-1/STS-3 Transport - Receive SF Defect Error Burst Tolerance Register - Byte 0 0x0258 Reserved 0x0259 Receive STS-1/STS-3 Transport - Receive SD Defect Clear Monitor Interval - Byte 2 R/W 0x00 0x025A Receive STS-1/STS-3 Transport - Receive SD Defect Clear Monitor Interval - Byte 1 R/W 0x00 0x025B Receive STS-1/STS-3 Transport - Receive SD Defect Clear Monitor Interval - Byte 0 R/W 0x00 0x025C Reserved 0x025D Receive STS-1/STS-3 Transport - Receive SF Defect Clear Monitor Interval - Byte 2 R/W 0x00 0x025E Receive STS-1/STS-3 Transport - Receive SF Defect Clear Monitor Interval - Byte 1 R/W 0x00 0x025F Receive STS-1/STS-3 Transport - Receive SF Defect Clear Monitor Interval - Byte 0 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 0x0260 - 0x0262 0x0263 0x0264 - 0x0266 0x0267 Reserved Receive STS-1/STS-3 Transport - Auto AIS Control Register Reserved Receive STS-1/STS-3 Transport - Serial Port Control Register 0x0268 - 0x026A Reserved 0x026B Receive STS-1/STS-3 Transport - Auto AIS (in Downstream T1/E1) Register 0x026C - 0x026D Reserved 0x026E Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register - Byte 1 RUR 0x00 0x026F Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register - Byte 0 RUR 0x00 0x0270 - 0x0279 Reserved 0x027A Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect Address Register - Byte 1 W 0x00 0x027B Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect Address Register - Byte 0 W 0x00 0x027C Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect Data Register - Byte 3 W 0x00 0x027D Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect Data Register - Byte 2 W 0x00 9 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 4: RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x027E Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect Data Register - Byte 1 W 0x00 0x027F Receive STS-1/STS-3 Transport - Receive TOH Capture Buffer - Indirect Data Register - Byte 0 W 0x00 0x0280 Reserved TYPE DEFAULT VALUE R/W 0x00 R/W 0x00 TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME 0x0281 Receive STS-1/STS-3 Path - Receive Control Register - Byte 2 0x0282 Reserved 0x0283 Receive STS-1/STS-3 Path - Receive Control Register - Byte 0 0x0284 - 0x0285 Reserved 0x0286 Receive STS-1/STS-3 Path - Receive Status Register - Byte 1 R/O 0x00 0x0287 Receive STS-1/STS-3 Path - Receive Status Register - Byte 0 R/O 0x00 0x0288 Reserved 0x0289 Receive STS-1/STS-3 Path - Receive Interrupt Status Register - Byte 2 RUR 0x00 0x028A Receive STS-1/STS-3 Path - Receive Interrupt Status Register - Byte 1 RUR 0x00 0x028B Receive STS-1/STS-3 Path - Receive Interrupt Status Register - Byte 0 RUR 0x00 0x028C Reserved 0x028D Receive STS-1/STS-3 Path - Receive Interrupt Enable Register - Byte 2 R/W 0x00 0x028E Receive STS-1/STS-3 Path - Receive Interrupt Enable Register - Byte 1 R/W 0x00 0x028F Receive STS-1/STS-3 Path - Receive Interrupt Enable Register - Byte 0 R/W 0x00 R/O & R/W 0x00 0x0290 - 0x0292 0x0293 0x0294 - 0x295 Reserved Receive STS-1/STS-3 Path - Receive RDI-P Register Reserved 0x0296 Receive STS-1/STS-3 Path - Receive C2 (Path Label) Byte Accepted Register R/O 0xFF 0x0297 Receive STS-1/STS-3 Path - Receive C2 (Path Label) Byte Expected Register R/W 0xFF 0x0298 Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte 3 RUR 0x00 0x0299 Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte 2 RUR 0x00 0x029A Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte 1 RUR 0x00 10 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x029B Receive STS-1/STS-3 Path - Receive B3 Byte Error Count Register - Byte 0 RUR 0x00 0x029C Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 3 RUR 0x00 0x029D Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 2 RUR 0x00 0x029E Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 1 RUR 0x00 0x029F Receive STS-1/STS-3 Path - Receive REI-P Event Count Register - Byte 0 RUR 0x00 R/W 0x00 0x02A0 - 0x02A2 Reserved 0x02A3 Receive STS-1/STS-3 Path - Receive J1 Byte/Path Trace Message Control Register 0x02A4 - 0x02A5 Reserved 0x02A6 Receive STS-1/STS-3 - Receive Pointer Value Register - Byte 1 R/O 0x00 0x02A7 Receive STS-1/STS-3 - Receive Pointer Value Register - Byte 0 R/O 0x00 R/O 0x00 R/O 0x00 0x02A8 - 0x02AA Reserved 0x02AB Receive STS-1/STS-3 - Receive LOP-C Status Register 0x02AC - 0x02B2 Reserved 0x02B3 Receive STS-1/STS-3 - Receive AIS-C Status Register 0x02B4 - 0x02B8 Reserved 0x02B9 Receive STS-1/STS-3 - Receive Auto AIS - C2 Byte Value Register R/W 0x00 0x02BA Receive STS-1/STS-3 - Receive Auto AIS - C2 Byte Control Register R/W 0x00 0x02BB Receive STS-1/STS-3 - Receive Auto AIS Control Register R/W 0x00 R/W 0x00 0x02BC - 0x02BE Reserved 0x02BF 0x02C0 -0x02C2 Receive STS-1/STS-3 - Receive Serial Port Control Register Reserved 0x02C3 Receive STS-1/STS-3 - Auto AIS (in Downstream T1/E1) Register R/W 0x00 0x02C4 Receive STS-1/STS-3 - Receive Negative Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x02C5 Receive STS-1/STS-3 - Receive Negative Pointer Adjustment Count Register - Byte 0 RUR 0x00 0x02C6 Receive STS-1/STS-3 - Receive Positive Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x02C7 Receive STS-1/STS-3 - Receive Positive Pointer Adjustment Count Register - Byte 0 RUR 0x00 R/O 0x00 0x02C8 - 0x02D2 Reserved 0x02D3 Receive STS-1/STS-3 - Receive J1 Byte Value Register 0x02D4 - 0x02D6 Reserved 11 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 5: RECEIVE STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION 0x02D7 REGISTER NAME Receive STS-1/STS-3 - Receive B3 Byte Value Register TYPE DEFAULT VALUE R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 0x02D8 - 0x02DA Reserved 0x02DB Receive STS-1/STS-3 - Receive C2 Byte Value Register 0x02DC - 0x02DE Reserved 0x02DF Receive STS-1/STS-3 - Receive G1 Byte Value Register 0x02E0 - 0x02E2 Reserved 0x02E3 Receive STS-1/STS-3 - Receive F2 Byte Value Register 0x02E4 - 0x02E6 Reserved 0x02E7 Receive STS-1/STS-3 - Receive H4 Byte Value Register 0x02E8 - 0x02EA Reserved 0x02EB Receive STS-1/STS-3 - Receive Z3 Byte Value Register 0x02EC - 0x02EE Reserved 0x02EF Receive STS-1/STS-3 - Receive Z4 Byte Value Register 0x02F0 - 0x02F2 Reserved 0x02F3 Receive STS-1/STS-3 - Receive Z5 Byte Value Register 0x02F4 - 0x02FF Reserved TABLE 6: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER ADDRESS LOCATION TYPE DEFAULT VALUE 0x0300 - 0x033F Receive STS-1/STS-3 Transport - Receive Section Trace Message Buffer R/O 0x00 0x0340 - 0x03FF Reserved R/O 0x00 REGISTER NAME TABLE 7: RECEIVE STS-1/STS-3 PATH - RECEIVE PATH TRACE MESSAGE BUFFER ADDRESS LOCATION TYPE DEFAULT VALUE 0x0400 - 0x043F Receive STS-1/STS-3 Path - Receive Path Trace Message Buffer R/O 0x00 0x0440 - 0x0580 Reserved R/O 0x00 REGISTER NAME TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION REGISTER NAME 0x0581 Receive TU-3 Path - Receive Control Register - Byte 2 0x0582 Reserved 12 TYPE DEFAULT VALUE R/W 0x00 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION 0x0583 REGISTER NAME Receive TU-3 Path - Receive Control Register - Byte 0 TYPE DEFAULT VALUE R/W 0x00 0x0584 - 0x0585 Reserved 0x0586 Receive TU-3 Path - Receive Status Register - Byte 1 R/O 0x00 0x0587 Receive TU-3 Path - Receive Status Register - Byte 0 R/O 0x00 0x0588 Reserved 0x0589 Receive TU-3 Path - Receive Interrupt Status Register - Byte 2 RUR 0x00 0x058A Receive TU-3 Path - Receive Interrupt Status Register - Byte 1 RUR 0x00 0x058B Receive TU-3 Path - Receive Interrupt Status Register - Byte 0 RUR 0x00 0x058C Reserved 0x058D Receive TU-3 Path - Receive Interrupt Enable Register - Byte 2 R/W 0x00 0x058E Receive TU-3 Path - Receive Interrupt Enable Register - Byte 1 R/W 0x00 0x058F Receive TU-3 Path - Receive Interrupt Enable Register - Byte 0 R/W 0x00 R/O & R/W 0x00 0x0590 - 0x0592 Reserved 0x0593 Receive TU-3 Path - Receive RDI-P Register 0x0594 - 0x0595 Reserved 0x0596 Receive TU-3 Path - Receive C2 (Path Label) Byte Accepted Register R/O 0xFF 0x0597 Receive TU-3 Path - Receive C2 (Path Label) Byte Expected Register R/W 0xFF 0x0598 Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 3 RUR 0x00 0x0599 Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 2 RUR 0x00 0x059A Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 1 RUR 0x00 0x059B Receive TU-3 Path - Receive B3 Byte Error Count Register - Byte 0 RUR 0x00 0x059C Receive TU-3 Path - Receive REI-P Event Count Register - Byte 3 RUR 0x00 0x059D Receive TU-3 Path - Receive REI-P Event Count Register - Byte 2 RUR 0x00 0x059E Receive TU-3 Path - Receive REI-P Event Count Register - Byte 1 RUR 0x00 0x059F Receive TU-3 Path - Receive REI-P Event Count Register - Byte 0 RUR 0x00 R/W 0x00 R/O 0x00 R/O 0x00 0x05A0 - 0x05A2 Reserved 0x05A3 Receive TU-3 Path - Receive J1 Byte/Path Trace Message Control Register 0x05A4 - 0x05A5 Reserved 0x05A6 Receive TU-3 Path - Receive Pointer Value Register - Byte 1 0x05A7 Receive TU-3 Path - Receive Pointer Value Register - Byte 0 0x05A8 - 0x05AA Reserved 0x05AB Receive TU-3 Path - Receive LOP-C Status Register 13 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE R/O 0x00 0x05AC - 0x05B2 Reserved 0x05B3 Receive TU-3 Path - Receive AIS-C Status Register 0x05B4 - 0x05B8 Reserved 0x05B9 Receive TU-3 Path - Receive Auto AIS - C2 Byte Value Register R/W 0x00 0x05BA Receive TU-3 Path - Receive Auto AIS - C2 Byte Control Register R/W 0x00 0x05BB Receive TU-3 Path - Receive Auto AIS Control Register R/W 0x00 R/W 0x00 0x05BC - 0x05BE Reserved 0x05BF Receive TU-3 Path - Receive Serial Port Control Register 0x05C0 - 0x05C2 Reserved 0x05C3 Receive TU-3 Path - Auto AIS (in Downstream T1/E1) Register R/W 0x00 0x05C4 Receive TU-3 Path - Receive Negative Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x05C5 Receive TU-3 Path - Receive Negative Pointer Adjustment Count Register - Byte 0 RUR 0x00 0x05C6 Receive TU-3 Path - Receive Positive Pointer Adjustment Count Register Byte 1 RUR 0x00 0x05C7 Receive TU-3 Path - Receive Positive Pointer Adjustment Count Register Byte 0 RUR 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 R/O 0x00 0x05C8 - 0x05D2 Reserved 0x05D3 Receive TU-3 Path - Receive J1 Byte Value Register 0x05D4 - 0x05D6 Reserved 0x05D7 Receive TU-3 Path - Receive B3 Byte Value Register 0x05D8 - 0x05DA Reserved 0x05DB Receive TU-3 Path - Receive C2 Byte Value Register 0x05DC - 0x05DE Reserved 0x05DF Receive TU-3 Path - Receive G1 Byte Value Register 0x05E0 - 0x05E2 Reserved 0x05E3 Receive TU-3 Path - Receive F2 Byte Value Register 0x05E4 - 0x05E6 Reserved 0x05E7 Receive TU-3 Path - Receive H4 Byte Value Register 0x05E8 - 0x05EA Reserved 0x05EB Receive TU-3 Path - Receive Z3 Byte Value Register 0x05EC - 0x05EE Reserved 0x05EF Receive TU-3 Path - Receive Z4 Byte Value Register 14 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 8: RECEIVE TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE R/O 0x00 0x05F0 - 0x05F2 Reserved 0x05F3 Receive TU-3 Path - Receive Z5 Byte Value Register 0x05F4 - 0x05FF Reserved TABLE 9: RECEIVE TU-3 POH PROCESSOR BLOCK - RECEIVE PATH TRACE MESSAGE BUFFER (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION REGISTER NAME 0x0600 - 0x063F Receive TU-3 POH Processor Block - Receive Path Trace Message Buffer TYPE DEFAULT VALUE R/O 0x00 0x0640 - 0x06FF Reserved TABLE 10: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0700 Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 3 R/W 0x00 0x0701 Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 2 R/W 0x00 0x0702 Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 1 R/W 0x00 0x0703 Transmit STS-1/STS-3 Transport - Transmit Control Register - Byte 0 R/W 0x00 0x0704 - 0x0715 Reserved 0x0716 Transmit STS-1/STS-3 Transport - Transmit A1 Byte Error Mask Register Byte 1 R/W 0x00 0x0717 Transmit STS-1/STS-3 Transport - Transmit A1 Byte Error Mask Register Byte 0 R/W 0x00 0x0718 - 0x071D Reserved 0x071E Transmit STS-1/STS-3 Transport - Transmit A2 Byte Error Mask Register Byte 1 R/W 0x00 0x071F Transmit STS-1/STS-3 Transport - Transmit A2 Byte Error Mask Register Byte 0 R/W 0x00 Transmit STS-1/STS-3 Transport - Transmit B1 Byte Error Mask Register R/W 0x00 0x0726 Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Mask Register Byte 1 R/W 0x00 0x0727 Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Mask Register Byte 0 R/W 0x00 0x0720 - 0x0722 Reserved 0x0723 0x0724 - 0x0725 0x0728 - 0x072A Reserved 15 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 10: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION 0x072B REGISTER NAME TYPE DEFAULT VALUE Transmit STS-1/STS-3 Transport - Transmit B2 Byte Bit Error Mask Register R/W 0x00 0x072C - 0x072D Reserved 0x072E Transmit STS-1/STS-3 Transport - Transmit K1 Byte Value Register R/W 0x00 0x072F Transmit STS-1/STS-3 Transport - Transmit K2 Byte Value Register R/W 0x00 0x0730 - 0x0732 Reserved 0x0733 Transmit STS-1/STS-3 Transport - Transmit RDI-L Control Register R/W 0x00 0x0734 Transmit STS-1/STS-3 Transport - Transmit M0/M1 Byte Control Register R/W 0x00 0x0735 Reserved 0x0736 Transmit STS-1/STS-3 Transport - Transmit M0/M1 Byte Pointer Register R/W 0x00 0x0737 Transmit STS-1/STS-3 Transport - Transmit M0/M1 Byte Value Register R/W 0x00 0x0738 Transmit STS-1/STS-3 Transport - Transmit S1 Byte Control Register R/W 0x00 0x0739 Reserved 0x073A Transmit STS-1STS-3 Transport - Transmit S1 Pointer Register R/W 0x00 0x073B Transmit STS-1/STS-3 Transport - Transmit S1 Byte Value Register R/W 0x00 0x073C Transmit STS-1/STS-3 Transport - Transmit F1 Byte Control Register R/W 0x00 0x073D Reserved 0x073E Transmit STS-1/STS-3 Transport - Transmit F1 Byte Pointer Register R/W 0x00 0x073F Transmit STS-1/STS-3 Transport - Transmit F1 Byte Value Register R/W 0x00 0x0740 Transmit STS-1/STS-3 Transport - Transmit E1 Byte Control Register R/W 0x00 0x0741 Reserved 0x0742 Transmit STS-1/STS-3 Transport - Transmit E1 Pointer Register R/W 0x00 0x0743 Transmit STS-1/STS-3 Transport - Transmit E1 Byte Value Register R/W 0x00 0x0744 Transmit STS-1/STS-3 Transport - Transmit E2 Byte Control Register R/W 0x00 0x0745 Reserved 0x0746 Transmit STS-1/STS-3 Transport - Transmit E2 Byte Pointer Register R/W 0x00 0x0747 Transmit STS-1/STS-3 Transport - Transmit E2 Byte Value Register R/W 0x00 R/W 0x00 R/W 0x00 0x0748 - 0x074A Reserved 0x074B Transmit STS-1/STS-3 Transport - Transmit J0 Byte Value Register 0x074C -0x074E Reserved 0x074F Transmit STS-1/STS-3 Transport - Transmit J0 Byte/Section Trace Message Control Register 0x0750 - 0x0780 Reserved 16 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 11: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0781 Transmit STS-1/STS-3 Path - Transmit Path Control Register - Byte 2 R/W 0x00 0x0782 Transmit STS-1/STS-3 Path - Transmit Path Control Register - Byte 1 R/W 0x00 0x0783 Transmit STS-1/STS-3 Path - Transmit Path Control Register - Byte 0 R/W 0x00 R/W 0x00 0x0784 - 0x0792 0x0793 0x0794 - 0x0796 Reserved Transmit STS-1/STS-3 Path - Transmit J1 Byte Value Register Reserved 0x0796 Transmit STS-1/STS-3 Path - Transmit B3 Byte Pass Thru Register R/W 0x00 0x0797 Transmit STS-1/STS-3 Path - Transmit B3 Byte Mask Register R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 0x0798 - 0x079A 0x079B Reserved Transmit STS-1/STS-3 Path - Transmit C2 Byte Value Register 0x079C - 0x079E Reserved 0x079F Transmit STS-1/STS-3 Path - Transmit G1 Byte Value Register 0x07A0 - 0x07A2 Reserved 0x07A3 Transmit STS-1/STS-3 Path - Transmit F2 Byte Value Register 0x07A4 - 0x07A6 Reserved 0x07A7 Transmit STS-1/STS-3 Path - Transmit H4 Byte Value Register 0x07A8 - 0x07AA Reserved 0x07AB Transmit STS-1/STS-3 Path - Transmit Z3 Byte Value Register 0x07AC - 0x07AE Reserved 0x07AF Transmit STS-1/STS-3 Path - Transmit Z4 Byte Value Register 0x07B0 - 0x07B2 Reserved 0x07B3 Transmit STS-1/STS-3 Path - Transmit Z5 Byte Value Register 0x07B4 - 0x07B6 Reserved 0x07B7 Transmit STS-1/STS-3 Path - Transmit Control Register - Byte 0 0x07B8 - 0x07BA Reserved 0x07BB Transmit STS-1/STS-3 Path - Transmit J1 Byte/Path Trace Message Control Register 0x07BC - 0x07BE Reserved 0x07BF Transmit STS-1/STS-3 Path - Transmit Arbitrary Pointer (H1 Byte) Value Register 0x07C0 - 0x07C2 Reserved 0x07C3 Transmit STS-1/STS-3 Path - Transmit Arbitrary Pointer (H2 Byte) Value Register 17 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 11: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x07C4 - 0x07C5 Reserved 0x07C6 Transmit STS-1/STS-3 Path - Current Pointer Value Register - High-Byte R/O 0x02 0x07C7 Transmit STS-1/STS-3 Path - Current Pointer Value Register - Low-Byte R/O 0x0A 0x07C8 Reserved 0x07C9 Transmit STS-1/STS-3 Path - Transmit RDI-P Control Register - Byte 2 R/W 0x00 0x07CA Transmit STS-1/STS-3 Path - Transmit RDI-P Control Register - Byte 1 R/W 0x00 0x07CB Transmit STS-1/STS-3 Path - Transmit RDI-P Control Register - Byte 0 R/W 0x00 0x07CA - 0x07CE Reserved 0x07CF Transmit STS-1/STS-3 Path - Transmit Path Serial Port Control Register R/W 0x00 0x07D0 Transmit STS-1/STS-3 - Transmit Negative Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x07D1 Transmit STS-1/STS-3 - Transmit Negative Pointer Adjustment Count Register - Byte 0 RUR 0x00 0x07D2 Transmit STS-1/STS-3 - Transmit Positive Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x07D3 Transmit STS-1/STS-3 - Transmit Positive Pointer Adjustment Count Register - Byte 0 RUR 0x00 0x07D4 - 0x07FF Reserved TABLE 12: TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ADDRESS LOCATION REGISTER NAME 0x0800 - 0x083F Transmit STS-1/STS-3 Transport - Transmit Section Trace Message Buffer TYPE DEFAULT VALUE R/W 0x00 0x0840 - 0x08FF Reserved TABLE 13: TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ADDRESS LOCATION TYPE DEFAULT VALUE 0x0900 - 0x093F Transmit STS-1/STS-3 Path - Transmit Path Trace Message Buffer R/W 0x00 0x0940 - 0x0A80 Reserved R/O 0x00 REGISTER NAME 18 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 14: TRANSMIT TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0A81 Transmit TU-3 Path - Transmit Path Control Register - Byte 2 R/W 0x00 0x0A82 Transmit TU-3 Path - Transmit Path Control Register - Byte 1 R/W 0x00 0x0A83 Transmit TU-3 Path - Transmit Path Control Register - Byte 0 R/W 0x00 R/W 0x00 0x0A84 -0x0A92 0x0A93 Reserved Transmit TU-3 Path - Transmit J1 Byte Value Register 0x0A94 - 0x0A95 Reserved 0x0A96 Transmit TU-3 Path - Transmit B3 Byte Pass Thru Register R/W 0x00 0x0A97 Transmit TU-3 Path - Transmit B3 Byte Mask Register R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 R/W 0x00 0x0A98 - 0x0A9A Reserved 0x0A9B Transmit TU-3 Path - Transmit C2 Byte Value Register 0x0A9C - 0x0A9E Reserved 0x0A9F Transmit TU-3 Path - Transmit G1 Byte Value Register 0x0AA0 - 0x0AA2 Reserved 0x0AA3 Transmit TU-3 Path - Transmit F2 Byte Value Register 0x0AA4 - 0x0AA6 Reserved 0x0AA7 Transmit TU-3 Path - Transmit H4 Byte Value Register 0x0AA8 - 0x0AAA Reserved 0x0AAB Transmit TU-3 Path - Transmit Z3 Byte Value Register 0x0AAC - 0x0AAE Reserved 0x0AAF Transmit TU-3 Path - Transmit Z4 Byte Value Register 0x0AB0 - 0x0AB2 Reserved 0x0AB3 Transmit TU-3 Path - Transmit Z5 Byte Value Register 0x0AB4 - 0x0AB6 Reserved 0x0AB7 Transmit TU-3 Path - Transmit Control Register - Byte 0 0x0AB8 - 0x0ABA Reserved 0x0ABB Transmit TU-3 Path - Transmit J1 Byte/Path Trace Message Control Register 0x0ABC - 0x0ABE Reserved 0x0ABF Transmit TU-3 Path - Transmit Arbitrary Pointer (H1 Byte) Value Register 0x0AC0 -0x0AC2 Reserved 0x0AC3 Transmit TU-3 Path - Transmit Arbitrary Pointer (H2 Byte) Value Register 0x0AC4 - 0x0AC5 Reserved 19 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 14: TRANSMIT TU-3 POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 APPLICATIONS ONLY) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0AC6 Transmit TU-3 Path - Current Pointer Value Register - High Byte R/O 0x02 0x0AC7 Transmit TU-3 Path - Current Pointer Value Register - Low Byte R/O 0x0A 0x0AC8 Reserved 0x0AC9 Transmit TU-3 Path - Transmit RDI-P Control Register - Byte 2 R/W 0x00 0x0ACA Transmit TU-3 Path - Transmit RDI-P Control Register - Byte 1 R/W 0x00 0x0ACB Transmit TU-3 Path - Transmit RDI-P Control Register - Byte 0 R/W 0x00 0x0ACC - 0x0ACE Reserved 0x0ACF Transmit TU-3 Path - Transmit Path Serial Port Control Register R/W 0x00 0x0AD0 Transmit TU-3 Path - Transmit Negative Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x0AD1 Transmit TU-3 Path - Transmit Negative Pointer Adjustment Count Register - Byte 0 RUR 0x00 0x0AD2 Transmit TU-3 Path - Transmit Positive Pointer Adjustment Count Register - Byte 1 RUR 0x00 0x0AD3 Transmit TU-3 Path - Transmit Positive Pointer Adjustment Count Register - Byte 0 RUR 0x00 Reserved R/O 0x00 0x0AD4 - 0xAFF TABLE 15: TRANSMIT TU-3 POH PROCESSOR BLOCK - TRANSMIT PATH TRACE MESSAGE BUFFER ADDRESS LOCATION TYPE DEFAULT VALUE 0x0B00 - 0x0B3F Transmit TU-3 POH Processor Block - Transmit Path Trace Message Buffer R/W 0x00 0x0B40 - 0x0BFF Reserved R/O 0x00 TYPE DEFAULT VALUE R/W 0x00 REGISTER NAME TABLE 16: VT MAPPER CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME 0x0C00 - 0x0C02 Reserved 0x0C03 Global Control - VT Mapper Control Block - VT Mapper Block Level Control Register 0x0C04 - 0x0C05 Reserved 0x0C06 Global Control - VT Mapper Control Block - Composite Status Register R/O 0x00 0x0C07 Global Control - VT Mapper Control Block - Composite Status Register R/O 0x00 0x0C08 - 0x0C09 Reserved 20 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 16: VT MAPPER CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0C0A Global Control - VT Mapper Control Block - Composite Interrupt Enable Register R/W 0x00 0x0C0B Global Control - VT Mapper Control Block - Composite Interrupt Enable Register R/W 0x00 0x0C0C - 0x0C0D Reserved 0x0C0E Global Control - VT Mapper Control Block - Test Pattern Control Register Byte 1 R/W & R/O 0x00 0x0C0F Global Control - VT Mapper Control Block - Test Pattern Control Register Byte 0 R/O 0x00 0x0C10 - 0x0C11 Reserved 0x0C12 Global Control - VT Mapper Control Block - Test Pattern Drop Register Byte 1 R/W 0x00 0x0C13 Global Control - VT Mapper Control Block - Test Pattern Drop Register Byte 0 R/W 0x00 0x0C14 - 0x0C15 Reserved 0x0C16 Global Control - VT Mapper Control Block - Test Pattern Detector Error Register - Upper Byte RUR 0x00 0x0C17 Global Control - VT Mapper Control Block - Test Pattern Detector Error Register - Lower Byte RUR 0x00 0x0C18 - 0x0C19 Reserved 0x0C1A Global Control - VT Mapper Control Block - Transmit Tributary Size Select Register - Byte 1 R/W 0x00 0x0C1B Global Control - VT Mapper Control Block - Transmit Tributary Size Select Register - Byte 0 R/W 0x00 0x0C1C - 0x0C1D Reserved 0x0C1E Global Control - VT Mapper Control Block - Receive Tributary Size Select Register - Byte 1 R/W 0x00 0x0C1F Global Control - VT Mapper Control Block - Receive Tributary Size Select Register - Byte 0 R/W 0x00 0x0C20 - 0x0D01 Reserved TABLE 17: DS3 MAPPER CONTROL REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0D02 DS3 Mapper Block - Control Register - Byte 1 R/W 0x03 0x0D03 DS3 Mapper Block - Control Register - Byte 0 R/W 0x00 R/O 0x03 0x0D04 - 0x0D05 Reserved 0x0D06 DS3 Mapper Block - Receive Mapper Status Register - Byte 1 21 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 17: DS3 MAPPER CONTROL REGISTERS ADDRESS LOCATION 0x0D07 REGISTER NAME DS3 Mapper Block - Receive Mapper Status Register - Byte 0 TYPE DEFAULT VALUE R/O 0x00 RUR 0x00 R/W 0x00 0x0D08 - 0x0D0A Reserved 0x0D0B DS3 Mapper Block - Receive Mapper Interrupt Status Register - Byte 0 0x0D0C - 0x0D0D Reserved 0x0D0E DS3 Mapper Block - Receive Mapper Interrupt Enable Register - Byte 0 0x0D0F - 0x0D20 Reserved 0x0D21 Pointer Justification Status Register - Byte 2 R/O 0x00 0x0D22 Pointer Justification Status Register - Byte 1 R/O 0x00 0x0D23 Pointer Justification Status Register - Byte 0 R/O 0x00 0x0D24 - 0x0D25 Reserved 0x0D26 Pointer Justification Jitter Control Register - Byte 1 R/W 0xC0 0x0D27 Pointer Justification Jitter Control Register - Byte 0 R/W 0x80 0x0D28 - 0x0DFF Reserved TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0E00 DS3 Framer and M13 MUX Block - Operating Mode Register R/W 0x23 0x0E01 DS3 Framer and M13 MUX Block - I/O Control Register R/W 0xC0 0x0E02 - 0x0E03 Reserved 0x0E04 DS3 Framer and M13 MUX Block - Block Interrupt Enable Register R/W 0x00 0x0E05 DS3 Framer and M13 MUX Block - Block Interrupt Status Register R/O 0x00 0x0E06 Reserved R/W 0x00 0x0E07 DS3 Framer and M13 MUX Block - M23 Configuration Register R/W 0x00 0x0E08 DS3 Framer and M13 MUX Block - M23 Transmit DS2 AIS Register R/W 0x00 0x0E09 DS3 Framer and M13 MUX Block - M23 DS2 Loop-back Request Register R/W 0x00 0x0E0A DS3 Framer and M13 MUX Block - M23 Loop-back Activation Register R/W 0x00 0x0E0B DS3 Framer and M13 MUX Block - M23 MUX Force DS2 AIS Command Register R/W 0x00 0x0E0C DS3 Framer and M13 MUX Block - DS3 Test Register # 1 R/W 0x00 0x0E0D Reserved R/O 0x00 0x0E0E DS3 Framer and M13 MUX Block - DS3 Test Register # 2 R/W 0x00 22 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0E10 DS3 Framer and M13 MUX Block - Receive DS3 Configuration & Status Register R/W 0x10 0x0E11 DS3 Framer and M13 MUX Block - Receive DS3 Status Register R/W 0x00 0x0E12 DS3 Framer and M13 MUX Block - Receive DS3 Interrupt Enable Register R/W 0x00 0x0E13 DS3 Framer and M13 MUX Block - Receive DS3 Interrupt Status Register RUR 0x00 0x0E14 DS3 Framer and M13 MUX Block - Receive DS3 Sync Detect Register R/W 0x00 0x0E15 Reserved R/O 0x00 0x0E16 S3 Framer and M13 MUX Block - Receive DS3 FEAC Register R/O 0x7E 0x0E17 DS3 Framer and M13 MUX Block - Receive DS3 FEAC Interrupt Enable/Status Register R/W 0x00 0x0E18 DS3 Framer and M13 MUX Block - Receive DS3 LAPD Control Register R/W 0x00 0x0E19 DS3 Framer and M13 MUX Block - Receive DS3 LAPD Status Register R/W 0x00 0x0E1A M12 DS2 # 1 Configuration Register R/W 0x00 0x0E1B DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2 Channel # 2 R/W 0x00 0x0E1C DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2 Channel # 3 R/W 0x00 0x0E1D DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2 Channel # 4 R/W 0x00 0x0E1E DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2 Channel # 5 R/W 0x00 0x0E1F DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2 Channel # 6 R/W 0x00 0x0E20 DS3 Framer and M13 MUX Block - M12 Configuration Register - DS2 Channel # 7 R/W 0x00 0x0E21 DS3 Framer and M13 MUX Block - M12 De-MUX Force DS1/E1 AIS Register - DS2 # Channel 1 R/W 0x00 0x0E22 DS3 Framer and M13 MUX Block - M12 DS2 # 2 AIS Register R/W 0x00 0x0E23 DS3 Framer and M13 MUX Block - M12 DS2 # 3 AIS Register R/W 0x00 0x0E24 DS3 Framer and M13 MUX Block - M12 DS2 # 4 AIS Register R/W 0x00 0x0E25 DS3 Framer and M13 MUX Block - M12 DS2 # 5 AIS Register R/W 0x00 0x0E26 DS3 Framer and M13 MUX Block - M12 DS2 # 6 AIS Register R/W 0x00 0x0E27 DS3 Framer and M13 MUX Block - M12 DS2 # 7 AIS Register R/W 0x00 0x0E28 M12 DS2 # 1 Loop-back Request Register R/W 0x00 0x0E29 M12 DS2 # 2 Loop- back Request Register R/W 0x00 0x0E2A M12 DS2 # 3 Loop-back Request Register R/W 0x00 23 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0E2B M12 DS2 # 4 Loop-back Request Register R/W 0x00 0x0E2C M12 DS2 # 5 Loop-back Request Register R/W 0x00 0x0E2D M12 DS2 # 6 Loop-back Request Register R/W 0x00 0x0E2E M12 DS2 # 7 Loop-back Request Register R/W 0x00 0x0E2F Reserved R/O 0x00 0x0E30 Transmit DS3 Configuration Register R/W 0x00 0x0E31 Transmit DS3 FEAC Configuration & Status Register R/W 0x00 0x0E32 Transmit DS3 FEAC Register R/W 0x7E 0x0E33 Transmit DS3 LAPD Configuration Register R/W 0x00 0x0E34 Transmit DS3 LAPD Status/Interrupt Register R/W 0x00 0x0E35 Transmit DS3 M-Bit Mask Register R/W 0x00 0x0E36 Transmit DS3 F-Bit Mask Register # 1 R/W 0x00 0x0E37 Transmit DS3 F-Bit Mask Register # 2 R/W 0x00 0x0E38 Transmit DS3 F-Bit Mask Register # 3 R/W 0x00 0x0E39 Transmit DS3 F-Bit Mask Register # 4 R/W 0x00 0x0E3A M12 DS2 # 1 Framer Configuration Register R/W 0x00 0x0E3B M12 DS2 # 2 Framer Configuration Register R/W 0x00 0x0E3C M12 DS2 # 3 Framer Configuration Register R/W 0x00 0x0E3D M12 DS2 # 4 Framer Configuration Register R/W 0x00 0x0E3E M12 DS2 # 5 Framer Configuration Register R/W 0x00 0x0E3F M12 DS2 # 6 Framer Configuration Register R/W 0x00 0x0E40 M12 DS2 # 7 Framer Configuration Register R/W 0x00 R/O 0x00 0x0E41 - 0x0E4B Reserved 0x0E4C Transmit DS3 Pattern Register R/W 0x00 0x0E4D Auto T1/E1 AIS upon DS3 Defect Condition Register R/W 0x00 0x0E4E PMON EXZ Event Count Register - MSB RUR 0x00 0x0E4F PMON EXZ Event Count Register - LSB RUR 0x00 0x0E50 PMON LCV Event Count Register - MSB RUR 0x00 0x0E51 PMON LCV Event Count Register - LSB RUR 0x00 0x0E52 PMON Framing Bit Error Count Register - MSB RUR 0x00 0x0E53 PMON Framing Bit Error Count Register - LSB RUR 0x00 0x0E54 PMON P-Bit Error Count Register - MSB RUR 0x00 24 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0E55 PMON P-Bit Error Count Register - LSB RUR 0x00 0x0E56 PMON FEBE Count Register - MSB RUR 0x00 0x0E57 PMON FEBE Count Register - LSB RUR 0x00 0x0E58 PMON CP-Bit Error Count Register - MSB RUR 0x00 0x0E59 PMON CP-Bit Error Count Register - LSB RUR 0x00 0x0E5A PMON DS2 # 1 Framing Bit Error Count Register RUR 0x00 0x0E5B PMON DS2 # 2 Framing Bit Error Count Register RUR 0x00 0x0E5C PMON DS2 # 3 Framing Bit Error Count Register RUR 0x00 0x0E5D PMON DS2 # 4 Framing Bit Error Count Register RUR 0x00 0x0E5E PMON DS2 # 5 Framing Bit Error Count Register RUR 0x00 0x0E5F PMON DS2 # 6 Framing Bit Error Count Register RUR 0x00 0x0E60 PMON DS2 # 7 Framing Bit Error Count Register RUR 0x00 0x0E61 PMON G.747 # 1 Parity Bit Error Count Register RUR 0x00 0x0E62 PMON G.747 # 2 Parity Bit Error Count Register RUR 0x00 0x0E63 PMON G.747 # 3 Parity Bit Error Count Register RUR 0x00 0x0E64 PMON G.747 # 4 Parity Bit Error Count Register RUR 0x00 0x0E65 PMON G.747 # 5 Parity Bit Error Count Register RUR 0x00 0x0E66 PMON G.747 # 6 Parity Bit Error Count Register RUR 0x00 0x0E67 PMON G.747 # 7 Parity Bit Error Count Register RUR 0x00 0x0E68 PRBS Bit Error Count Register - MSB RUR 0x00 0x0E69 PRBS Bit Error Count Register - LSB RUR 0x00 0x0E6A - 0x0E6C Reserved 0x0E6D One Second Error Status Register R/O 0x00 0x0E6E LCV One Second Accumulator Register - MSB R/O 0x00 0x0E6F LCV One Second Accumulator Register - LSB R/O 0x00 0x0E70 Frame Parity Error One Second Accumulator Register - MSB R/O 0x00 0x0E71 Frame Parity Error One Second Accumulator Register - LSB R/O 0x00 0x0E72 CP Bit Error One Second Accumulator Register - MSB R/O 0x00 0x0E73 CP Bit Error One Second Accumulator Register - LSB R/O 0x00 R/O 0x00 0x0E74 - 0x0E7F Reserved 0x0E80 Line Interface Drive Register R/W 0x00 0x0E81 Line Interface Scan Register R/W 0x00 25 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0E82 Reserved R/O 0x00 0x0E83 Transmit DS3 LAPD Byte Count Register R/W 0x00 0x0E84 Receive DS3 LAPD Byte Count Register R/O 0x00 0x0E85 - 0x0E8F Reserved 0x0E90 M23 Receive DS2 Loop-back Request Interrupt Enable Register R/W 0x00 0x0E91 M23 Receive DS2 Loop-back Request Interrupt Status Register RUR 0x00 0x0E92 M23 Receive DS2 Loop-back Request Status Register R/O 0x00 0x0E93 M12 DS2 # 1 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0E94 M12 DS2 # 1 Loop-back Status Register R/O 0x00 0x0E95 M12 DS2 # 2 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0E96 M12 DS2 # 2 Loop-back Status Register R/O 0x00 0x0E97 M12 DS2 # 3 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0E98 M12 DS2 # 3 Loop-back Status Register R/O 0x00 0x0E99 M12 DS2 # 4 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0E9A M12 DS2 # 4 Loop-back Status Register R/O 0x00 0x0E9B M12 DS2 # 5 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0E9C M12 DS2 # 5 Loop-back Status Register R/O 0x00 0x0E9D M12 DS2 # 6 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0E9E M12 DS2 # 6 Loop-back Status Register R/O 0x00 0x0E9F M12 DS2 # 7 Loop-back Interrupt/Interrupt Enable Register R/W, RUR 0x00 0x0EA0 M12 DS2 # 7 Loop-back Status Register R/O 0x00 0x0EA1 DS2 # 1 Framer Interrupt Enable Register R/W 0x00 0x0EA2 DS2 # 1 Framer Interrupt Status Register RUR 0x00 0x0EA3 DS2 # 1 Framer Status Register R/O 0x00 0x0EA4 DS2 # 2 Framer Interrupt Enable Register R/W 0x00 0x0EA5 DS2 # 2 Framer Interrupt Status Register RUR 0x00 0x0EA6 DS2 # 2 Framer Status Register R/O 0x00 0x0EA7 DS2 # 3 Framer Interrupt Enable Register R/W 0x00 0x0EA8 DS2 # 3 Framer Interrupt Status Register RUR 0x00 0x0EA9 DS2 # 3 Framer Status Register R/O 0x00 0x0EAA DS2 # 4 Framer Interrupt Enable Register R/W 0x00 0x0EAB DS2 # 4 Framer Interrupt Status Register RUR 0x00 26 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 18: DS3 FRAMER AND M13 MUX BLOCK REGISTERS ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0x0EAC DS2 # 4 Framer Status Register R/O 0x00 0x0EAD DS2 # 5 Framer Interrupt Enable Register R/W 0x00 0x0EAE DS2 # 5 Framer Interrupt Status Register RUR 0x00 0x0EAF DS2 # 5 Framer Status Register R/O 0x00 0x0EB0 DS2 # 6 Framer Interrupt Enable Register R/W 0x00 0x0EB1 DS2 # 6 Framer Interrupt Status Register RUR 0x00 0x0EB2 DS2 # 6 Framer Status Register R/O 0x00 0x0EB3 DS2 # 7 Framer Interrupt Enable Register R/W 0x00 0x0EB4 DS2 # 7 Framer Interrupt Status Register RUR 0x00 0x0EB5 DS2 # 7 Framer Status Register R/O 0x00 R/W 0x00 0x0EB6 -0x0EB7 Reserved 0x0EB8 M13 DeMUX External Alarm Enable Register 0x0EB9 - 0x0EBF Reserved 0x0EC0 LAPD Memory Indirect Address Register R/W 0x00 0x0EC1 LAPD Memory Indirect Data Register R/W 0x00 R/O 0x00 0x0EC2 - 0x0FFF Reserved TABLE 19: T1/E1 LIU CHANNEL CONTROL REGISTERS (WHERE N RANGES FROM 0X01 TO 0X1D) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN000 T1/E1 LIU Register - Byte 0 - Channel 0 R/W 0x00 0xN001 LIU Channel Control Register - Byte 1 - Channel 0 R/W 0x00 0xN002 LIU Channel Control Register - Byte 2 - Channel 0 R/W 0x00 0xN003 LIU Channel Control Register - Byte 3 - Channel 0 R/W 0x00 0xN004 LIU Channel Control Register - Byte 4 - Channel 0 R/W 0x00 0xN005 LIU Channel Control Register - Byte 5 - Channel 0 R/W 0x00 0xN006 LIU Channel Control Register - Byte 6 - Channel 0 R/W 0x00 0xN007 LIU Channel Control Register - Byte 7 - Channel 0 R/W 0x00 0xN008 LIU Channel Control Register - Byte 8 - Channel 0 R/W 0x00 0xN009 LIU Channel Control Register - Byte 9 - Channel 0 R/W 0x00 0xN00A LIU Channel Control Register - Byte 10 - Channel 0 R/W 0x00 0xN00B LIU Channel Control Register - Byte 11 - Channel 0 R/W 0x00 0xN00C LIU Channel Control Register - Byte 12 - Channel 0 R/W 0x00 27 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 19: T1/E1 LIU CHANNEL CONTROL REGISTERS (WHERE N RANGES FROM 0X01 TO 0X1D) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN00D LIU Channel Control Register - Byte 13 - Channel 0 R/W 0x00 0xN00E LIU Channel Control Register - Byte 14 - Channel 0 R/W 0x00 0xN00F LIU Channel Control Register - Byte 15 - Channel 0 R/W 0x00 0xN010 LIU Channel Control Register - Byte 16 - Channel 0 R/W 0x00 0xN011 LIU Channel Control Register - Byte 17 - Channel 0 R/W 0x00 0xN012 - 0xN0FF Reserved TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN100 Clock Select Register R/W 0x00 0xN101 Line Interface Control Register R/W 0x00 Reserved RUR 0xN107 Framing Select Register R/W 0x00 0xN108 Alarm Generation Register R/W 0x00 0xN109 Synchronization Mux Register R/W 0x00 0xN10A Transmit Signaling and Data Link Select Register R/W 0x00 0xN10B Framing Control Register R/W 0x00 0xN10C Receive Signaling Data Link Select Register R/W 0x00 0xN10D Receive Signaling Change Register - 0Framing Control Register (E1 Applications Only) R/W 0x00 0xN10E Receive Signaling Change Register - 1 R/W 0x00 0xN10F Receive Signaling Change Register - 2 R/W 0x00 0xN110 Reserved 0xN111 Receive National Bits Register (E1 Applications Only) R/W 0x00 0xN112 Receive Extra Bits (E1 Applications)Receive In-Sync Register (T1 Applications) R/W 0x00 0xN113 Data Link control Register R/W 0x00 0xN114 Transmit Data Link Byte Count Register R/W 0x00 0xN115 Receive Data Link Byte Count Register R/W 0x00 0xN102 - 0N106 0xN116 - 0xN117 Reserved 0x1118 DMA 0 Write Configuration Register R/W 0x00 0x1119 DMA 1 Read Configuration Register R/W 0x00 28 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN11A Reserved 0xN11B LAPD Channel Select Register (T1 Applications) R/W 0x00 0xN11C Customer Installation Alarm Generation Register R/W 0x00 0xN11D Transmit Performance Report Control Register R/W 0x00 0xN11E - 0xN11 Reserved 0xN120 Transmit Interface Control Register R/W 0x00 0xN121 DS1/E1 Test Register - 2 R/W 0x00 0xN122 Receive Interface Control Register R/W 0x00 0xN123 DS1/E1 Test Register - 1 R/W 0x00 0xN124 Loop Back Code Control Register - Code 0 R/W 0x00 0xN125 Transmit Loop Back Code Control Register R/W 0x00 0xN126 Receive Loop Back Code Activation Control Register - Code 0 R/W 0x00 0xN127 Receive Loop Back Code Deactivation Control Register - Code 0 R/W 0x00 0xN129 Receive DS1 External Alarm Enable Register R/W 0x00 0xN12A Loop-Back Code Control Register - Code 1 R/W 0x00 0xN12B Receive Loop Back Code Activation Control Register - Code 1 R/W 0x00 0xN12C Receive Loop Back Code Deactivation Control Register - Code 1 R/W 0x00 0xN12D Loop-back Code Control Register - Code 2 R/W 0x00 0xN12E Receive Loop-back Activation Code Control Register - Code 2 R/W 0x00 0xN12F Receive Loop-back Deactivation Code Control Register - Code 2 R/W 0x00 0xN130 Transmit Sa Select Register (E1 Applications Only) R/W 0x00 0xN131 Transmit Sa Auto Control Register - Byte 1 (E1 Applications Only) R/W 0x00 0xN132 Transmit Sa Auto Control Register - Byte 2 (E1 Applications Only) R/W 0x00 0xN133 Transmit Sa4 Register (E1 Applications Only) R/W 0x00 0xN134 Transmit Sa5 Register (E1 Applications Only) R/W 0x00 0xN135 Transmit Sa6 Register (E1 Applications Only) R/W 0x00 0xN136 Transmit Sa7 Register (E1 Applications Only) R/W 0x00 0xN137 Transmit Sa8 Register (E1 Applications Only) R/W 0x00 0xN138 - 0xN13A Reserved 0xN13B Receive Sa4 Register (E1 Applications Only) R/W 0x00 0xN13C Receive Sa5 Register (E1 Applications Only) R/W 0x00 0xN13D Receive Sa6 Register (E1 Applications Only) R/W 0x00 29 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 20: T1/E1 FRAMER BLOCK CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) REGISTER NAME TYPE DEFAULT VALUE 0xN13E Receive Sa7 Register (E1 Applications Only) R/W 0x00 0xN13F Receive Sa8 Register (E1 Applications Only) R/W 0x00 R/W 0x00 ADDRESS LOCATION 0xN140 - 0xN142 Reserved 0xN142 Transmit SPRM Control Register 0xN143 - 0xN2FF Reserved TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN300 Transmit Channel Control Register - Channel 0 R/W 0x00 0xN301 Transmit Channel Control Register - Channel 1 R/W 0x00 0xN302 Transmit Channel Control Register - Channel 2 R/W 0x00 0xN303 Transmit Channel Control Register - Channel 3 R/W 0x00 0xN304 Transmit Channel Control Register - Channel 4 R/W 0x00 0xN305 Transmit Channel Control Register - Channel 5 R/W 0x00 0xN306 Transmit Channel Control Register - Channel 6 R/W 0x00 0xN307 Transmit Channel Control Register - Channel 7 R/W 0x00 0xN308 Transmit Channel Control Register - Channel 8 R/W 0x00 0xN309 Transmit Channel Control Register - Channel 9 R/W 0x00 0xN30A Transmit Channel Control Register - Channel 10 R/W 0x00 0xN30B Transmit Channel Control Register - Channel 11 R/W 0x00 0xN30C Transmit Channel Control Register - Channel 12 R/W 0x00 0xN30D Transmit Channel Control Register - Channel 13 R/W 0x00 0xN30E Transmit Channel Control Register - Channel 14 R/W 0x00 0xN30F Transmit Channel Control Register - Channel 15 R/W 0x00 0xN310 Transmit Channel Control Register - Channel 16 R/W 0x00 0xN311 Transmit Channel Control Register - Channel 17 R/W 0x00 0xN312 Transmit Channel Control Register - Channel 18 R/W 0x00 0xN313 Transmit Channel Control Register - Channel 19 R/W 0x00 0xN314 Transmit Channel Control Register - Channel 20 R/W 0x00 0xN315 Transmit Channel Control Register - Channel 21 R/W 0x00 0xN316 Transmit Channel Control Register - Channel 22 R/W 0x00 0xN317 Transmit Channel Control Register - Channel 23 R/W 0x00 30 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN318 Transmit Channel Control Register - Channel 24 (E1 Applications Only) R/W 0x00 0xN319 Transmit Channel Control Register - Channel 25 (E1 Applications Only) R/W 0x00 0xN31A Transmit Channel Control Register - Channel 26 (E1 Applications Only) R/W 0x00 0xN31B Transmit Channel Control Register - Channel 27 (E1 Applications Only) R/W 0x00 0xN31C Transmit Channel Control Register - Channel 28 (E1 Applications Only) R/W 0x00 0xN31D Transmit Channel Control Register - Channel 29 (E1 Applications Only) R/W 0x00 0xN31E Transmit Channel Control Register - Channel 30 (E1 Applications Only) R/W 0x00 0xN31F Transmit Channel Control Register - Channel 31 (E1 Applications Only) R/W 0x00 0xN320 User (IDLE) Code Register - Channel 0 R/W 0x00 0xN321 User (IDLE) Code Register - Channel 1 R/W 0x00 0xN322 User (IDLE) Code Register - Channel 2 R/W 0x00 0xN323 User (IDLE) Code Register - Channel 3 R/W 0x00 0xN324 User (IDLE) Code Register - Channel 4 R/W 0x00 0xN325 User (IDLE) Code Register - Channel 5 R/W 0x00 0xN326 User (IDLE) Code Register - Channel 6 R/W 0x00 0xN327 User (IDLE) Code Register - Channel 7 R/W 0x00 0xN328 User (IDLE) Code Register - Channel 8 R/W 0x00 0xN329 User (IDLE) Code Register - Channel 9 R/W 0x00 0xN32A User (IDLE) Code Register - Channel 10 R/W 0x00 0xN32B User (IDLE) Code Register - Channel 11 R/W 0x00 0xN32C User (IDLE) Code Register - Channel 12 R/W 0x00 0xN32D User (IDLE) Code Register - Channel 13 R/W 0x00 0xN32E User (IDLE) Code Register - Channel 14 R/W 0x00 0xN32F User (IDLE) Code Register - Channel 15 R/W 0x00 0xN330 User (IDLE) Code Register - Channel 16 R/W 0x00 0xN331 User (IDLE) Code Register - Channel 17 R/W 0x00 0xN332 User (IDLE) Code Register - Channel 18 R/W 0x00 0xN333 User (IDLE) Code Register - Channel 19 R/W 0x00 0xN334 User (IDLE) Code Register - Channel 20 R/W 0x00 0xN335 User (IDLE) Code Register - Channel 21 R/W 0x00 0xN336 User (IDLE) Code Register - Channel 22 R/W 0x00 0xN337 User (IDLE) Code Register - Channel 23 R/W 0x00 31 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN338 User (IDLE) Code Register - Channel 24 (E1 Applications Only) R/W 0x00 0xN339 User (IDLE) Code Register - Channel 25 (E1 Applications Only) R/W 0x00 0xN33A User (IDLE) Code Register - Channel 26 (E1 Applications Only) R/W 0x00 0xN33B User (IDLE) Code Register - Channel 27 (E1 Applications Only) R/W 0x00 0xN33C User (IDLE) Code Register - Channel 28 (E1 Applications Only) R/W 0x00 0xN33D User (IDLE) Code Register - Channel 29 (E1 Applications Only) R/W 0x00 0xN33E User (IDLE) Code Register - Channel 30 (E1 Applications Only) R/W 0x00 0xN33F User (IDLE) Code Register - Channel 31 (E1 Applications Only) R/W 0x00 0xN340 Transmit Signaling Control Register - Channel 0 R/W 0x00 0xN341 Transmit Signaling Control Register - Channel 1 R/W 0x00 0xN342 Transmit Signaling Control Register - Channel 2 R/W 0x00 0xN343 Transmit Signaling Control Register - Channel 3 R/W 0x00 0xN344 Transmit Signaling Control Register - Channel 4 R/W 0x00 0xN345 Transmit Signaling Control Register - Channel 5 R/W 0x00 0xN346 Transmit Signaling Control Register - Channel 6 R/W 0x00 0xN347 Transmit Signaling Control Register - Channel 7 R/W 0x00 0xN348 Transmit Signaling Control Register - Channel 8 R/W 0x00 0xN349 Transmit Signaling Control Register - Channel 9 R/W 0x00 0xN34A Transmit Signaling Control Register - Channel 10 R/W 0x00 0xN34B Transmit Signaling Control Register - Channel 11 R/W 0x00 0xN34C Transmit Signaling Control Register - Channel 12 R/W 0x00 0xN34D Transmit Signaling Control Register - Channel 13 R/W 0x00 0xN34E Transmit Signaling Control Register - Channel 14 R/W 0x00 0xN34F Transmit Signaling Control Register - Channel 15 R/W 0x00 0xN350 Transmit Signaling Control Register - Channel 16 R/W 0x00 0xN351 Transmit Signaling Control Register - Channel 17 R/W 0x00 0xN352 Transmit Signaling Control Register - Channel 18 R/W 0x00 0xN353 Transmit Signaling Control Register - Channel 19 R/W 0x00 0xN354 Transmit Signaling Control Register - Channel 20 R/W 0x00 0xN355 Transmit Signaling Control Register - Channel 21 R/W 0x00 0xN356 Transmit Signaling Control Register - Channel 22 R/W 0x00 0xN357 Transmit Signaling Control Register - Channel 23 R/W 0x00 32 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN358 Transmit Signaling Control Register - Channel 24 (E1 Applications Only) R/W 0x00 0xN359 Transmit Signaling Control Register - Channel 25 (E1 Applications Only) R/W 0x00 0xN35A Transmit Signaling Control Register - Channel 26 (E1 Applications Only) R/W 0x00 0xN35B Transmit Signaling Control Register - Channel 27 (E1 Applications Only) R/W 0x00 0xN35C Transmit Signaling Control Register - Channel 28 (E1 Applications Only) R/W 0x00 0xN35D Transmit Signaling Control Register - Channel 29 (E1 Applications Only) R/W 0x00 0xN35E Transmit Signaling Control Register - Channel 30 (E1 Applications Only) R/W 0x00 0xN35F Transmit Signaling Control Register - Channel 31 (E1 Applications Only) R/W 0x00 0xN360 Receive Channel Control Register - Channel 0 R/W 0x00 0xN361 Receive Channel Control Register - Channel 1 R/W 0x00 0xN362 Receive Channel Control Register - Channel 2 R/W 0x00 0xN363 Receive Channel Control Register - Channel 3 R/W 0x00 0xN364 Receive Channel Control Register - Channel 4 R/W 0x00 0xN365 Receive Channel Control Register - Channel 5 R/W 0x00 0xN366 Receive Channel Control Register - Channel 6 R/W 0x00 0xN367 Receive Channel Control Register - Channel 7 R/W 0x00 0xN368 Receive Channel Control Register - Channel 8 R/W 0x00 0xN369 Receive Channel Control Register - Channel 9 R/W 0x00 0xN36A Receive Channel Control Register - Channel 10 R/W 0x00 0xN36B Receive Channel Control Register - Channel 11 R/W 0x00 0xN36C Receive Channel Control Register - Channel 12 R/W 0x00 0xN36D Receive Channel Control Register - Channel 13 R/W 0x00 0xN36E Receive Channel Control Register - Channel 14 R/W 0x00 0xN36F Receive Channel Control Register - Channel 15 R/W 0x00 0xN370 Receive Channel Control Register - Channel 16 R/W 0x00 0xN371 Receive Channel Control Register - Channel 17 R/W 0x00 0xN372 Receive Channel Control Register - Channel 18 R/W 0x00 0xN373 Receive Channel Control Register - Channel 19 R/W 0x00 0xN374 Receive Channel Control Register - Channel 20 R/W 0x00 0xN375 Receive Channel Control Register - Channel 21 R/W 0x00 0xN376 Receive Channel Control Register - Channel 22 R/W 0x00 0xN377 Receive Channel Control Register - Channel 23 R/W 0x00 33 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN378 Receive Channel Control Register - Channel 24 R/W 0x00 0xN379 Receive Channel Control Register - Channel 25 R/W 0x00 0xN37A Receive Channel Control Register - Channel 26 R/W 0x00 0xN37B Receive Channel Control Register - Channel 27 R/W 0x00 0xN37C Receive Channel Control Register - Channel 28 R/W 0x00 0xN37D Receive Channel Control Register - Channel 29 R/W 0x00 0xN37E Receive Channel Control Register - Channel 30 R/W 0x00 0xN37F Receive Channel Control Register - Channel 31 R/W 0x00 0xN380 Receive User Code Register - Channel 0 R/W 0x00 0xN381 Receive User Code Register - Channel 1 R/W 0x00 0xN382 Receive User Code Register - Channel 2 R/W 0x00 0xN383 Receive User Code Register - Channel 3 R/W 0x00 0xN384 Receive User Code Register - Channel 4 R/W 0x00 0xN385 Receive User Code Register - Channel 5 R/W 0x00 0xN386 Receive User Code Register - Channel 6 R/W 0x00 0xN387 Receive User Code Register - Channel 7 R/W 0x00 0xN388 Receive User Code Register - Channel 8 R/W 0x00 0xN389 Receive User Code Register - Channel 9 R/W 0x00 0xN38A Receive User Code Register - Channel 10 R/W 0x00 0xN38B Receive User Code Register - Channel 11 R/W 0x00 0xN38C Receive User Code Register - Channel 12 R/W 0x00 0xN38D Receive User Code Register - Channel 13 R/W 0x00 0xN38E Receive User Code Register - Channel 14 R/W 0x00 0xN38F Receive User Code Register - Channel 15 R/W 0x00 0xN390 Receive User Code Register - Channel 16 R/W 0x00 0xN391 Receive User Code Register - Channel 17 R/W 0x00 0xN392 Receive User Code Register - Channel 18 R/W 0x00 0xN393 Receive User Code Register - Channel 19 R/W 0x00 0xN394 Receive User Code Register - Channel 20 R/W 0x00 0xN395 Receive User Code Register - Channel 21 R/W 0x00 0xN396 Receive User Code Register - Channel 22 R/W 0x00 0xN397 Receive User Code Register - Channel 23 R/W 0x00 34 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN398 Receive User Code Register - Channel 24 R/W 0x00 0xN399 Receive User Code Register - Channel 25 R/W 0x00 0xN39A Receive User Code Register - Channel 26 R/W 0x00 0xN39B Receive User Code Register - Channel 27 R/W 0x00 0xN39C Receive User Code Register - Channel 28 R/W 0x00 0xN39D Receive User Code Register - Channel 29 R/W 0x00 0xN39E Receive User Code Register - Channel 30 R/W 0x00 0xN39F Receive User Code Register - Channel 31 R/W 0x00 0xN3A0 Receive Signaling Control Register - Channel 0 R/W 0x00 0xN3A1 Receive Signaling Control Register - Channel 1 R/W 0x00 0xN3A2 Receive Signaling Control Register - Channel 2 R/W 0x00 0xN3A3 Receive Signaling Control Register - Channel 3 R/W 0x00 0xN3A4 Receive Signaling Control Register - Channel 4 R/W 0x00 0xN3A5 Receive Signaling Control Register - Channel 5 R/W 0x00 0xN3A6 Receive Signaling Control Register - Channel 6 R/W 0x00 0xN3A7 Receive Signaling Control Register - Channel 7 R/W 0x00 0xN3A8 Receive Signaling Control Register - Channel 8 R/W 0x00 0xN3A9 Receive Signaling Control Register - Channel 9 R/W 0x00 0xN3AA Receive Signaling Control Register - Channel 10 R/W 0x00 0xN3AB Receive Signaling Control Register - Channel 11 R/W 0x00 0xN3AC Receive Signaling Control Register - Channel 12 R/W 0x00 0xN3AD Receive Signaling Control Register - Channel 13 R/W 0x00 0xN3AE Receive Signaling Control Register - Channel 14 R/W 0x00 0xN3AF Receive Signaling Control Register - Channel 15 R/W 0x00 0xN3B0 Receive Signaling Control Register - Channel 16 R/W 0x00 0xN3B1 Receive Signaling Control Register - Channel 17 R/W 0x00 0xN3B2 Receive Signaling Control Register - Channel 18 R/W 0x00 0xN3B3 Receive Signaling Control Register - Channel 19 R/W 0x00 0xN3B4 Receive Signaling Control Register - Channel 20 R/W 0x00 0xN3B5 Receive Signaling Control Register - Channel 21 R/W 0x00 0xN3B6 Receive Signaling Control Register - Channel 22 R/W 0x00 0xN3B7 Receive Signaling Control Register - Channel 23 R/W 0x00 35 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN3B8 Receive Signaling Control Register - Channel 24 R/W 0x00 0xN3B9 Receive Signaling Control Register - Channel 25 R/W 0x00 0xN3BA Receive Signaling Control Register - Channel 26 R/W 0x00 0xN3BB Receive Signaling Control Register - Channel 27 R/W 0x00 0xN3BC Receive Signaling Control Register - Channel 28 R/W 0x00 0xN3BD Receive Signaling Control Register - Channel 29 R/W 0x00 0xN3BE Receive Signaling Control Register - Channel 30 R/W 0x00 0xN3BF Receive Signaling Control Register - Channel 31 R/W 0x00 0xN3C0 Receive Substitution Signaling Register - Channel 0 R/W 0x00 0xN3C1 Receive Substitution Signaling Register - Channel 1 R/W 0x00 0xN3C2 Receive Substitution Signaling Register - Channel 2 R/W 0x00 0xN3C3 Receive Substitution Signaling Register - Channel 3 R/W 0x00 0xN3C4 Receive Substitution Signaling Register - Channel 4 R/W 0x00 0xN3C5 Receive Substitution Signaling Register - Channel 5 R/W 0x00 0xN3C6 Receive Substitution Signaling Register - Channel 6 R/W 0x00 0xN3C7 Receive Substitution Signaling Register - Channel 7 R/W 0x00 0xN3C8 Receive Substitution Signaling Register - Channel 8 R/W 0x00 0xN3C9 Receive Substitution Signaling Register - Channel 9 R/W 0x00 0xN3CA Receive Substitution Signaling Register - Channel 10 R/W 0x00 0xN3CB Receive Substitution Signaling Register - Channel 11 R/W 0x00 0xN3CC Receive Substitution Signaling Register - Channel 12 R/W 0x00 0xN3CD Receive Substitution Signaling Register - Channel 13 R/W 0x00 0xN3CE Receive Substitution Signaling Register - Channel 14 R/W 0x00 0xN3CF Receive Substitution Signaling Register - Channel 15 R/W 0x00 0xN3D0 Receive Substitution Signaling Register - Channel 16 R/W 0x00 0xN3D1 Receive Substitution Signaling Register - Channel 17 R/W 0x00 0xN3D2 Receive Substitution Signaling Register - Channel 18 R/W 0x00 0xN3D3 Receive Substitution Signaling Register - Channel 19 R/W 0x00 0xN3D4 Receive Substitution Signaling Register - Channel 20 R/W 0x00 0xN3D5 Receive Substitution Signaling Register - Channel 21 R/W 0x00 0xN3D6 Receive Substitution Signaling Register - Channel 22 R/W 0x00 0xN3D7 Receive Substitution Signaling Register - Channel 23 R/W 0x00 36 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 21: TRANSMIT CHANNEL CONTROL REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME 0xN3D8 0xN3FF Reserved 0xN400 0xN4FF Reserved TYPE DEFAULT VALUE R/O 0x00 TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) REGISTER NAME TYPE DEFAULT VALUE 0xN500 Receive Signaling Register Array - Channel 0 R/O 0x00 0xN501 Receive Signaling Register Array - Channel 1 R/O 0x00 0xN502 Receive Signaling Register Array - Channel 2 R/O 0x00 0xN503 Receive Signaling Register Array - Channel 3 R/O 0x00 0xN504 Receive Signaling Register Array - Channel 4 R/O 0x00 0xN505 Receive Signaling Register Array - Channel 5 R/O 0x00 0xN506 Receive Signaling Register Array - Channel 6 R/O 0x00 0xN507 Receive Signaling Register Array - Channel 7 R/O 0x00 0xN508 Receive Signaling Register Array - Channel 8 R/O 0x00 0xN509 Receive Signaling Register Array - Channel 9 R/O 0x00 0xN50A Receive Signaling Register Array - Channel 10 R/O 0x00 0xN50B Receive Signaling Register Array - Channel 11 R/O 0x00 0xN50C Receive Signaling Register Array - Channel 12 R/O 0x00 0xN50D Receive Signaling Register Array - Channel 13 R/O 0x00 0xN50E Receive Signaling Register Array - Channel 14 R/O 0x00 0xN50F Receive Signaling Register Array - Channel 15 R/O 0x00 0xN510 Receive Signaling Register Array - Channel 16 R/O 0x00 0xN511 Receive Signaling Register Array - Channel 17 R/O 0x00 0xN512 Receive Signaling Register Array - Channel 18 R/O 0x00 0xN513 Receive Signaling Register Array - Channel 19 R/O 0x00 0xN514 Receive Signaling Register Array - Channel 20 R/O 0x00 0xN515 Receive Signaling Register Array - Channel 21 R/O 0x00 0xN516 Receive Signaling Register Array - Channel 22 R/O 0x00 0xN517 Receive Signaling Register Array - Channel 23 R/O 0x00 0xN518 Receive Signaling Register Array - Channel 24 R/O 0x00 ADDRESS LOCATION 37 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN519 Receive Signaling Register Array - Channel 25 R/O 0x00 0xN51A Receive Signaling Register Array - Channel 26 R/O 0x00 0xN51B Receive Signaling Register Array - Channel 27 R/O 0x00 0xN51C Receive Signaling Register Array - Channel 28 R/O 0x00 0xN51D Receive Signaling Register Array - Channel 29 R/O 0x00 0xN51E Receive Signaling Register Array - Channel 30 R/O 0x00 0xN51F Receive Signaling Register Array - Channel 31 R/O 0x00 0xN520 - 0xN59F Reserved 0xN5A0 Receive Signaling Control Registers - Channel 0 R/W 0x00 0xN5A1 Receive Signaling Control Registers - Channel 1 R/W 0x00 0xN5A2 Receive Signaling Control Registers - Channel 2 R/W 0x00 0xN5A3 Receive Signaling Control Registers - Channel 3 R/W 0x00 0xN5A4 Receive Signaling Control Registers - Channel 4 R/W 0x00 0xN5A5 Receive Signaling Control Registers - Channel 5 R/W 0x00 0xN5A6 Receive Signaling Control Registers - Channel 6 R/W 0x00 0xN5A7 Receive Signaling Control Registers - Channel 7 R/W 0x00 0xN5A8 Receive Signaling Control Registers - Channel 8 R/W 0x00 0xN5A9 Receive Signaling Control Registers - Channel 9 R/W 0x00 0xN5AA Receive Signaling Control Registers - Channel 10 R/W 0x00 0xN5AB Receive Signaling Control Registers - Channel 11 R/W 0x00 0xN5AC Receive Signaling Control Registers - Channel 12 R/W 0x00 0xN5AD Receive Signaling Control Registers - Channel 13 R/W 0x00 0xN5AE Receive Signaling Control Registers - Channel 14 R/W 0x00 0xN5AF Receive Signaling Control Registers - Channel 15 R/W 0x00 0xN5B0 Receive Signaling Control Registers - Channel 16 R/W 0x00 0xN5B1 Receive Signaling Control Registers - Channel 17 R/W 0x00 0xN5B2 Receive Signaling Control Registers - Channel 18 R/W 0x00 0xN5B3 Receive Signaling Control Registers - Channel 19 R/W 0x00 0xN5B4 Receive Signaling Control Registers - Channel 20 R/W 0x00 0xN5B5 Receive Signaling Control Registers - Channel 21 R/W 0x00 0xN5B6 Receive Signaling Control Registers - Channel 22 R/W 0x00 0xN5B7 Receive Signaling Control Registers - Channel 23 R/W 0x00 38 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 22: RECEIVE SIGNALING REGISTER ARRAY REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) TYPE DEFAULT VALUE 0xN600 - 0xN640 LAPD Buffer 0 Control Register (64-Bytes) R/W 0x00 0xN700 - 0xN740 LAPD Buffer 1 Control Register (64-Bytes) R/W 0x00 ADDRESS LOCATION REGISTER NAME 0xN5B8 - 0xN5FF Reserved 0xN741 - 0xN8FF Reserved TABLE 23: T1/E1 PERFORMANCE MONITOR REGISTER (WHERE N RANGES VALUE FROM 0X01 TO 0X38) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xN900 T1 Receive Line Code Violation Count Register (MSB) RUR 0x00 0xN901 T1 Receive Line Code Violation Count Register (LSB) RUR 0x00 0xN902 T1/E1 Receive Frame Alignment Error Count Register - MSB RUR 0x00 0xN903 T1/E1 Receive Frame Alignment Error Count Register (LSB) RUR 0x00 0xN904 T1/E1 Receive Severely Erred Frame Count Register RUR 0x00 0xN905 T1/E1 Receive Synchronization Bit Error Count Register - MSB RUR 0x00 0xN906 T1/E1 Receive Synchronization Bit Error Count Register - LSB RUR 0x00 0xN907 T1/E1 Receive FEBE Event Count Register - MSB RUR 0x00 0xN908 T1/E1 Receive FEBE Event Count Register - LSB RUR 0x00 0xN909 T1/E1 Receive Slip Event Count Register RUR 0x00 0xN90A T1/E1 Receive Loss of Frame Count Register RUR 0x00 0xN90B T1/E1 Receive Change of Frame Count Register RUR 0x00 0xN90C LAPD Frame Check Sequence Error Count Register RUR 0x00 0xN90D T1/E1 PRBS Bit Error Count Register - MSB RUR 0x00 0xN90E T1/E1 PRBS Bit Error Count Register - LSB RUR 0x00 0xN90F T1/E1 Transmit Slip Event Count Register RUR 0x00 0xN910 - 0xNAFF Reserved TABLE 24: T1/E1 FRAMER BLOCK INTERRUPT REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xNB00 T1/E1 Framer Block Interrupt Enable Register R/W 0x00 0xNB01 T1/E1 Framer Block Interrupt Status Register R/O 0x00 0xNB02 Alarm and Error Status Register RUR 0x00 0xNB03 Alarm and Error Interrupt Enable Register R/W 0x00 39 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 24: T1/E1 FRAMER BLOCK INTERRUPT REGISTERS (WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xNB04 Framer Interrupt Enable Register R/W 0x00 0xNB05 Framer Interrupt Status Register RUR 0x00 0xNB06 Data Link Interrupt Status Register RUR 0x00 0xNB07 Data Link Interrupt Enable Register 0xNB0A Receive Loop Back Code Interrupt & Status Register - Code 0 R/W 0x00 0xNB0B Receive Loop Back Code Interrupt Enable Register - Code 0 R/W 0x00 0xNB0C - 0xNB0D Reserved 0xNB0E Excessive Zero Interrupt Status Register RUR 0x00 0xNB0F Excessive Zero Interrupt Enable Register RUR 0x00 0xNB10 Receive Sa Interrupt Enable Register (E1 Applications)SS7 Interrupt Status Register - LAPD # 1 (T1 Applications) R/W 0x00 0xNB11 Receive Sa Interrupt Enable Register (E1 Applications)SS7 Interrupt Enable Register - LAPD # 1 (T1 Applications) R/W 0x00 0xNB12 - 0xNB13 Reserved 0xNB14 Receive Loop-back Code Interrupt Status Register - Code 1 RUR v0x00 OxNB15 Receive Loop-back Code Interrupt Enable Register - Code 1 R/W 0x00v 0x00 0xNB16 - 0xNB17 Reserved 0xNB18 SS7 Interrupt Status Register - LAPD # 2 (T1 Applications) R/W 0xNB19 SS7 Interrupt Enable Register - LAPD # 2 (T1 Applications) R/W 0xNB1A Receive Loop-back Code Interrupt Status Register - Code 2 RUR 0x00 0xNB1B Receive Loop-back Code Interrupt Enable Register - Code 2 R/W 0x00 0xNB1C - 0xNB27 Reserved 0xNB28 SS7 Interrupt Status Register - LAPD # 3 (T1 Applications) R/W 0x00 0xNB29 SS7 Interrupt Enable Register - LAPD # 3 (T1 Applicaions) R/W 0x00 0xNB30 - 0xNB3F Reserved 0xNB40 Customer Installation Alarm Status Register RUR 0x00 0xNB41 Customer Installation Alarm Interrupt Enable Register R/W 0x00 R/O 0x00 0xNB42 - 0xNCFF Reserved 40 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 25: VT MAPPER REGISTER (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xND42 Channel Control - VT Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register - Byte 1 R/O & R/W 0x00 0xND43 Channel Control - VT-Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register - Byte 0 R/W 0x00 0xND44 Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop Control Register - Byte 3 R/W 0x00 0xND45 Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop Control Register - Byte 2 R/W 0x00 0xND46 Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop Control Register - Byte 1 R/O 0x10 0xND47 Channel Control - VT De-Mapper Block - Egress Direction - DS1/E1 Drop Control Register - Byte 0 R/O & R/W 0x00 0xND00 - 0xND41 Reserved 0xND48 - 0xND49 Reserved 0xND4A Channel Control - VT De-Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 1 RUR 0x00 0xND4B Channel Control - VT De-Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 0 RUR 0x00 0xND4C - 0xND4D Reserved 0xND4E Channel Control - VT De-Mapper Block - Egress Direction - REI-V Event Count Register - Byte 1 RUR 0x00 0xND4F Channel Control - VT-De-Mapper Block - Egress Direction - REI-V Event Count Register - Byte 0 RUR 0x00 R/W 0x00 0xND50 - 0xND52 Reserved 0xND53 Channel Control - VT-De-Mapper Block - Egress Direction - Receive APS Register - Byte 0 0xND54 - 0xND55 Reserved 0xND56 Channel Control - VT-Mapper Block - Ingress Direction - Transmit APS Register - Byte 1 R/W 0x00 0xND57 Channel Control - VT-Mapper Block - Ingress Direction - Transmit APS/K4 Register - Byte 0 R/W 0x00 0xND58 - 0xND62 Reserved 0xND63 Channel Control - VT-De-Mapper Block- Egress Direction - J2 Byte Status Register - Byte 0 R/O 0x00 0xND64 Channel Control - VT-De-Mapper Block - Egress Direction - Composite Status Register - Byte 1 RUR 0x00 0xND65 Channel Control - VT-De-Mapper Block - Egress Direction -Composite Status Register - Byte 0 RUR 0x00 41 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 25: VT MAPPER REGISTER (WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) ADDRESS LOCATION REGISTER NAME TYPE DEFAULT VALUE 0xND66 Reserved RUR 0x00 0xND67 Channel Control - VT-De-Mapper Block - Egress Direction - Interrupt Status Register - Byte 0 RUR 0x00 0xND68 Channel Control - VT-De-Mapper Block - Egress Direction - Interrupt Enable Register R/W 0x00 0xND69 Channel Control - VT-De-Mapper - Block - Egress Direction - Interrupt Enable Register R/W 0x00 0xND6A Reserved R/W 0x00 0xND6B Channel Control - VT-De-Mapper Block - Egress Direction -Interrupt Enable Register - Byte 0 R/W 0x00 0xND6C - 0xND70 Reserved 0xND71 Channel Control - VT-De-Mapper Block - Egress Direction - VT Path Trace Buffer Control Register R/W 0x00 0xND72 Channel Control - VT-De-Mapper Block - Egress Direction - Auto AIS Control Register - Byte 1 R/W 0x00 0xND73 Channel Control VT De-Mapper Block - Egress Direction - Auto AIS Control Register - Byte 0 R/W 0x00 0xND74 - 0xND75 Reserved 0xND76 Channel Control - VT-Mapper Block - Ingress Direction - Transmit J2 Byte Value Register R/W 0x00 0xND77 Channel Control - VT Mapper Block - Ingress Direction - Transmit N2 Byte Value Register R/W 0x00 2.0 REGISTER DESCRIPTIONS the remainder of this document use register descriptions with the folowing format: 8-BIT register table TABLE 26: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Bit Name Bit Name Bit Name Bit Name Bit Name Bit Name Bit Name Bit Name R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT descriptions BIT 7 - Bit name Bit Description ` 0 - Logic LOW condition ` 1 - Logic HIGH condition NOTE: Speial notes BIT [6:0] - Bit name 42 PRELIMINARY REV. P1.0.6 2.1 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS OPERATION CONTROL REGISTERS TABLE 27: OPERATION CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0000) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Ingress Direction Add-Drop Interface Enable Egress Direction Add-Drop Interface Enable Parallel Interface Enable R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Mode_Select[3:0] BIT7 - Unused BIT6 - Ingress Direction Add-Drop Interface Enable: This READ/WRITE bit-field is used to either enable or disable the Ingress Direction Add-Drop Interface. If the Ingress Direction Add-Drop Interface is enabled, then the Ingress Direction Drop Port will drop out the entire traffic (of all 28 channels in the Ingress Direction) via the IG_TE1RxDATA[7:0] output pins. Additionally, the user can add in of the 28 DS1 or 21 E1 Ingress Direction signals via the Ingress Direction Add Port. ` 0 - Disables the Ingress Direction Add-Drop Interface. ` 1 - Enables the Ingress Direction Add-Drop Interface. NOTE: This feature is only available if the XRT86SH328 has been configured to operate in either of the following modes.· • The VT-Mapper Mode (w/ T1/E1 Framing) • The M13 MUX Mode (w/ T1/E1 Framing) • The M13 MUX to STS-1/STS-3 Mode • The Transmux Mode BIT 5 - Egress Direction Add-Drop Interface Enable: This READ/WRITE bit-field is used to either enable or disable the Egress Direction Add-Drop Interface. If the user enables the Egress Direction Add-Drop Interface, then the Egress Direction Drop Port will drop out the entire traffic (of all 28 channels in the Egress Direction) via the EG_TE1RxDATA[7:0] output pins. Additionally, the user can add in any of the 28 DS1 or 21 E1 Egress Direction signals via the Egress Direction Add Interface. ` 0 - Disables the Egress Direction Add-Drop Interface. ` 1 - Enables the Egress Direction Add-Drop Interface. NOTE: This feature is only available if the XRT86SH328 has been configured to operate in either of the following modes. • The VT-Mapper Mode (w/ T1/E1 Framing) • The M13 MUX Mode (w/ T1/E1 Framing) • The M13 MUX to STS-1/STS-3 Mode • The Transmux Mode BIT 4 - Parallel Interface Enable NOTE: This bit-field is only valid if the XRT86SH328 has been configured to operate in the 28-Channel DS1/E1 Framer & LIU Mode. BIT[3:0] - Mode Select Bits[3:0]: These four READ/WRITE bit-fields are used to select the mode that the XRT86SH328 will operate in, as shown in the table below below. 43 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Mode Select Bits MODE_SELECT[3:0] RESULTING MODE OF OPERATION 0000 VT-Mapper Mode (w/ T1/E1 Framing) 0001 M13 MUX Mode (w/ T1/E1 Framing 0010 M13 MUX to STS-1/STS-3 Mode 0011 Reserved 0100 28 Channel T1/E1 Framer & LIU Mode 0101 Transmux Mode (w/ T1/E1 Framing) 0110 & 0111 Reserved 1000 VT-Mapper Mode (w T1/E1 Framers by-passed) 1001 M13 MUX Mode (w/ T1/E1 Framers by-passed) 1010 M13 MUX to STS-1/STS-3 Mode (w/ T1/E1 Framers by-passed) 1011 Reserved 1100 28 Channel T1/E1 LIU Mode 1101 Transmux Mode (w/ T1/E1 Framers by-passed) TABLE 28: OPERATION CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0001) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 Interrupt Write Clear/RUR Enable Interrupt Clear Interrupt Enable R/O R/O R/O R/O R/O R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:3] - Unused Please set to 0 for normal operation. BIT 2 - Interrupt Write to Clear/RUR This READ/WRITE bit-field is used to configure all of the Source-Level Interrupt Status bits (within the XRT86SH328) to either be Write to Clear (WTC) or Reset-upon-Read (RUR) bits. ` 0 - Configures all Source-Level Interrupt Status register bits to function as Reset-upon-Read (RUR). ` 1 - Configures all Source-Level Interrupt Status register bits to function as Write-to-Clear (WTC) BIT 1 - Enable Interrupt Clear This READ/WRITE bit-field is used to configure the XRT94L43 to automatically disable all interrupts that are activated. ` 0 - Configures the chip to NOT automatically disable any Interrupts following their activation. ` 1 - Configures the chip to automatically disable all Interrupts following their activation. BIT 0 - Interrupt Enable This READ/WRITE bit-field is used to configure the XRT94L43 to generate interrupt requests to the Microprocessor. ` 0 - Configures the chip to NOT generate interrupt to the Microprocessor. All interrupts are disabled and the Microprocessor must poll the register bits. ` 1 - Configures the chip to generate interrupts to the Microprocessor. 44 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: To operate the XRT986SH328 in an Interrupt-Driven Manner, this bit-field must be set to a logic 1. TABLE 29: OPERATION CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0003) BIT7 BIT6 BIT 5 BIT 4 Reserved Receive Clock Detect R/W R/W R/O R/O R/W R/O R/O R/W 0 1 0 0 0 0 0 0 Reserved BIT 3 BIT 2 Burst Enable BIT 1 Reserved BIT 0 SWRESET BIT7 - Reserved BIT6 - Receive Clock Detect This READ/WRITE bit-field is used to enable or disable the Receive Clock Detect feature. If this feature is enabled, then the Receive STS-1/STS-3 circuitry will check for the existence of the 6.48MHz or 19.44MHz clock signal (through the Receive STS-1/STS-3 Telecom Bus Interface). If none of these clock signals are present, then the Receive STS-1/STS-3 TOH Processor block and each of the 1 (or 3) Receive SONET POH Processor block circuitry will automatically switch over and use the 19.44MHz clock signal that is applied to the Tx19_51MHz input pin (Ball R3) as there timing source. ` 0 - Disables the Receive Clock Detect feature. ` 1 - Enables the Receive Clock Detect feature. BIT [5:4] = Reserved BIT 3 - Burst Enable This READ/WRITE bit-field is used to either enable or disable Burst Mode operation within the Microprocessor Interface. ` 0 - Disables Burst Mode operation. ` 1 - Enables Burst Mode operation BIT 2 - BIT 1 - Reserved BIT 0 - SWReset - SONET Block This READ/WRITE bit-field is used to command a software reset to the SONET/SDH block. If a software reset to the SONET/SDH blocks is invoked, then all of the internal state machines will be reset to their default conditions and each of the following blocks will undergo a re-frame operation. • The Receive STS-1/3 TOH Processor block • Each of the three (3) Receive SONET POH Processor blocks • Each of the three (3) VT Mapper Blocks A 0 to 1 transition, within this bit-field commands this Software Reset. NOTE: This Software Reset does not reset the command registers to their default state. This can only be achieved by executing a Hardware RESET (e.g., by pulling the RESET_L* input pin LOW). TABLE 30: DEVICE ID VALUE REGISTER - BYTE 3 (ADDRESS = 0X0004) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Device ID Value R/O R/O R/O R/O R/O R/O R/O R/O 0 1 0 1 0 0 0 0 BIT [7:0] - Device ID Value This READ-ONLY bit-field is set to the value 0x50 and is used's software code to uniquely identify this device as being the XRT86SH328. 45 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 31: REVISION NUMBER VALUE REGISTER - BYTE 2 (ADDRESS = 0X0005) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Revision Number Value R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 1 BIT [7:0] - Revision Number Value This READ-ONLY bit-field is set to the value that corresponds to its revision number. Revision A silicon will be set to the value 0x01. This register is uses software code to uniquely identify the revision number of this device TABLE 32: OPERATION INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X000B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Unused BIT 0 TB Parity Error Interrupt Status R/O R/O R/O R/O R/O R/O R/O RUR/WTC 0 0 0 0 0 0 0 0 BIT [7:1] - Unused Please set to 0 for normal operation BIT 0 - Telecom Bus Parity Error Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt has occurred since the last read of this register bit. ` 0 - Indicates that the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt has NOT occurred since the last read of this register bit. ` 1 - Indicates that the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt has occurred since the last of this register bit. NOTE: This register bit is only active if the XRT86SH328 has been configured to operate in the Telecom Bus Mode. TABLE 33: OPERATION INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X000F) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Unused BIT 0 Telecom BusParity Error Interrupt Enable R/O R/O R/O R/O R/O R/O R/O R/W 0 0 0 0 0 0 0 0 BIT [7:1] - Unused Please set to 0 for normal operation BIT 0 - Telecom Bus Parity Error Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt. ` 0 - Disables the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt. ` 1 - Enables the Detection of 51.84/155.52Mbps Telecom Bus - Parity Error interrupt.NOTE: This register bit is only active if the XRT86SH328 has been configured to operate in the Telecom Bus Mode. 46 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 34: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS = 0X0012) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Op Control Block Interrupt Status DS3 Mapper Block Interrupt Status VT Mapper Block Interrupt Status DS1/E1 Framer/LIU Block (VT Side) Interrupt Status DS1/E1 Framer/LIU Block (M13 Side) Interrupt Status DS3/E3 Framer Block nterrupt Status Receive Line Interface Block Interrupt Status Transmit Line Interface Block Interrupt Status R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - Operation Control Block Interrupt Status This READ-ONLY bit-field indicates whether or not an Operation Control Block-related Interrupt is awaiting service. ` 0 - No Operation Control Block Interrupts are awaiting service. ` 1 - At least one Operation Control Block Interrupt is awaiting service. BIT 6- DS3 Mapper Block Interrupt Status This READ-ONLY bit-field indicates whether or not a Mapper Block-related Interrupt is awaiting service. ` 0 - No Mapper Block interrupt is awaiting service. ` 1 - At least one Mapper Block Interrupt is awaiting service. BIT 5 - VT Mapper Block Interrupt Status This READ-ONLY bit-field indicates whether or not a VT-Mapper block interrupt is awaiting service. ` 0 - Indicates that no VT Mapper block interrupt is awaiting service. ` 1 - Indicates that at least one VT Mapper block interrupt is awaiting service. BIT 4 - DS1/E1 Framer/LIU Block (VT Side) Interrupt Status This READ-ONLY bit-field indicates whether or not a DS1/E1 Framer/LIU Block (on the VT Side) Interrupt is awaiting service. ` 0 - Indicates that no DS1/E1 Framer Block (VT Side) interrupt is awaiting service. ` 1 - At least one DS1/E1 Framer/LIU Block (VT Side) interrupt is awaiting service. BIT 3 - DS1/E1 Framer/LIU Block (M13 Side) Interrupt Status This READ-ONLY bit-field indicates whether or not a DS1/E1 Framer/LIU Block (M13 Side) Interrupt is awaiting service. ` 0 - No DS1/E1 Framer/LIU Block (M13 Side) interrupt is awaiting service. ` 1 - At least one DS1/E1 Framer/LIU (M13 Side) interrupt is awaiting service. BIT 2 - DS3/E3 Framer Block Interrupt Status This READ-ONLY bit-field indicates whether or not a DS3/E3 Framer Block interrupt is awaiting service. ` 0 - No DS3/E3 Framer block interrupt is awaiting service. ` 1 - At least one DS3/E3 Framer block interrupt is awaiting service. BIT 1:0 - Unused 47 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 35: OPERATION BLOCK INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0013) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused Receive STS-1/STS-3 TOH Block Interrupt Status Receive STS-1/STS-3 POH Block Interrupt Status R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 Unused BIT 2 BIT 1 External Interrupt Status # 1 BIT 0 Unused BIT 7 - Unused BIT 6 - Receive STS-1/ST3-3TOH Processor Block Interrupt Status This READ-ONLY bit-field indicates whether or not a Receive STS-1/STS-3 TOH Processor Block interrupt is awaiting service. ` 0 - No Receive STS-1/STS-3 TOH Processor Block Interrupt is awaiting service. ` 1 - At least one Receive STS-1/STS-3 TOH Processor Block interrupt is awaiting service. BIT 5 - Receive STS-1/STS-3 POH Processor Block Interrupt Status This READ-ONLY bit-field indicates whether or not a Receive STS-1/STS-3 POH Processor Block interrupt is awaiting service. ` 0 - No Receive STS-1/STS-3 POH Processor Block Interrupt is awaiting service. ` 1 - At least one Receive STS-1/STS-3 POH Processor Block Interrupt is awaiting service. BIT [4:3] - Unused BIT 2 - External Interrupt Input Pin # 1 - Interrupt Status This READ-ONLY bit-field indicates whether or not an External Interrupt Input Pin # 1 Interrupt is awaiting service, as described below. ` 0 - No External Interrupt Input Pin # 1 Interrupt is awaiting service. ` 1 - The External Interrupt Input Pin # 1 Interrupt is awaiting service. NOTE: If this interrupt is enabled, then the XRT86SH328 will generate this interrupt anytime that the EXT_INT_1 Input pin (Ball T5) has been driven to the logic HIGH level. BIT [1:0] - Unused TABLE 36: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS = 0X0016) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Op Control Block Interrupt Enable DS3Mapper Block Interrupt Enable VT Mapper Block Interrupt Enable DS1/E1 Framer/LIU Block (VT Side) Interrupt Enable DS1/E1 Framer/LIU Block (M13 Side) Interrupt Enable DS3Framer Block nterrupt Enable R/W R/W R/W R/W R/W R/W R/O R/O 0 0 0 0 0 0 0 0 Unused BIT 7 - Operation Control Block Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Operation Control Block for interrupt generation. If a 0 is written to this register bit and if the Operation Control Block (for interrupt generation) is disabled, then all Operation Control Block interrupts will be disabled for interrupt generation. If a 1 is written to this register bit, the individual Operation Control Block interrupt(s) at the Source Level will still need 48 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS to be enabled in order to enable that particular interrupt ` .0 - Disable all Operation Control Block interrupts within the device. ` 1 - Enables the Operation Control Block at the Block-Level for interrupt generation BIT 6 - DS3 Mapper Block Interrupt Enable This READ/WRITE bit is used to either enable or disable the DS3 Mapper Block for interrupt generation. If a 0 is written to this register bit and if the DS3 Mapper Block (for interrupt generation) is disabled, then all DS3 Mapper Block interrupts will be disabled for interrupt generation. If a 1is written to this register bit, the individual DS3 Mapper Block interrupt(s) at the Source Levelwill still need to be enabled in order to enable that particular interrupt. ` 0 - Disable all DS3 Mapper Block interrupts within the device. ` 1 - Enables the DS3 Mapper Block interrupts at the Block-Level BIT 5 - VT Mapper Block Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the VT-Mapper Block for interrupt generation. If the user writes a 0 into this register bit and disables the VT Mapper Block (for interrupt generation) then all VT-Mapper Block interrupts will be disabled for interrupt generation. If the user writes a 1 into this register bit, the user will still need to enable the individual VT-Mapper Block Interrupt(s) at the Source Level in order to enable that particular interrupt. ` 0 - Disables all VT Mapper Block Interrupts within the device. ` 1 - Enables the VT Mapper Block Interrupts at the Block-Level BIT 4- DS1/E1 Framer/LIU Block (VT Side) Interrupt Enable This READ/WRITE bit is used to either enable or disable the DS1/E1 Framer/LIU Block (on the VT Side) for interrupt generation. If the user writes a 0 to this register bit and disables the DS1/E1 Framer/LIU Block (on the VT Side) for interrupt generation, then all DS1/E1 Framer/LIU Block interrupts will be disabled for interrupt generation. If the user writes a 1 to this register bit, the user will still need to enable the individual DS1/E1 Framer/LIU Block interrupt(s) at the Source Level in order to enable that particular interrupt. ` 0 - Disable all DS1/E1 Framer/LIU Block interrupts within the device. ` 1 - Enables the DS1/E1 Framer/LIU Block at the Block-Level. BIT 3 - DS1/E1 Framer/LIU Block (M13 Side) Interrupt Enable This READ/WRITE bit is used to either enable or disable the DS1/E1 Framer/LIU Block (on the M13 Side) for interrupt generation. If the user writes a 0 to this register bit and disables the DS1/E1 Framer/LIU Block (for interrupt generation), then all DS1/E1 Framer/LIU Block interrupts will be disabled for interrupt generation. If the user writes a 1 to this register bit, the user will still need to enable the individual DS1/E1 Framer/LIU Block interrupt(s) at the Source Level in order to enable that particular interrupt. ` 0 - Disable all DS1/E1 Framer/LIU Block interrupts within the device, ` 1 - Enables the DS1/E1 Framer/LIU Block interrupts at the Block-Level. BIT 2 - DS3 Framer Block Interrupt Enable This READ/WRITE bit is used to either enable or disable the DS3 Framer Block for interrupt generation. If the user writes a 0 to this register bit and disables the DS3 Framer Block (for interrupt generation), then all DS3 Framer Block interrupts will be disabled for interrupt generation. If the user writes a 1 to this register bit, the user will still need to enable the individual DS3 Framer Block interrupt(s) at the Source Level in order to enable that particular interrupt. ` 0 - Disable all DS3 Framer Block interrupts within the device. ` 1 - Enables the DS3 Framer Block at the Block-Level. BIT [1:0] - Unused 49 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 37: OPERATION BLOCK INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0017) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused Receive STS-1/STS-3 TOHBlock Interrupt Enable Receive STS-1 POH Block Interrupt Enable R/O R/W R/W R/O R/O R/W R/W R/O 0 0 0 0 0 0 0 0 Unused BIT 2 BIT 1 External Interrupt Enable # 1 BIT 0 Unused BIT 7 - Unused BIT 6 - Receive STS-1/STS-3 TOH Processor Block Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Receive STS-1/STS-3 TOH Processor Block for interrupt generation. If the user writes a 0 to this register bit and disables the Receive STS-1/STS-3 TOH Processor Block (for interrupt generation), then all Receive STS-1/STS-3 TOH Processor Block interrupts will be disabled for interrupt generation. If the user writes a 1 to this register bit, the user will still need to enable the individual Receive STS-1/STS-3 TOH Processor Block interrupt(s) at the Source Level in order to enable that particular interrupt. ` 0 - Disables all Receive STS-1/STS-3 TOH Processor Block interrupts within the device. ` 1 - Enables the Receive STS-1/STS-3 TOH Processor Block at the Block Level for interrupt generation. BIT 5 - Receive STS-1/STS-3 POH Processor Block Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Receive STS-1/STS-3 POH Processor Block for interrupt generation. If the user writes a 0 into this register bit and disables the Receive STS-1/STS-3 POH Processor Block (for interrupt generation), then all Receive STS-1/STS-3 Processor Block interrupts will be disabled for interrupt generation. If the user writes a 1 to this register bit, then the user will still need to enable the individual Receive STS-1/STS-3 POH Processor Block Interrupt(s) at the Source Level in order to enable that particular interrupt. ` 0 - Disables all Receive STS-1/STS-3 POH Processor Block Interrupts within the device. ` 1 - Enables the Receive STS-1/STS-3 POH Processor Block at the Block Level for interrupt generation. BIT [4:3] - Unused BIT 2 - External Interrupt Input Pin # 1 - Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the External Interrupt Pin # 1 Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt anytime that the EXT_INT_1 input pin (Ball T5) has been driven to the logic HIGH level. ` 0 - Disables the External Interrupt Input # 1 Interrupt ` 1 - Enables the External Interrupt Input # 1 Interrupt. BIT [1:0] - Unused 50 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 38: MODE CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 T1/E1 De-Sync Disable STS-1/STS-3 & DS3 Share Serial Interface Additional T1/E1 Framers Enabled R/W R/W R/W R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Unused BIT 0 AU-3/TUG_3* BIT 7 - T1/E1 De-Sync Disable This READ/WRITE bit-field is used to either enable or disable the T1/E1 De-Sync Circuitry within the XRT86SH328. ` 0 - Enables the T1/E1 De-Sync Circuitry. ` 1 - Disables the T1/E1 De-Sync Circuitry. BIT 6 - STS-1/STS-3 and DS3 Share Serial Interface This READ/WRITE bit-field is used to configure the DS3 and STS-1/STS-3 circuitry to either share the same Serial Interface or not. To operate the XRT86SH328 in the Transmux mode, then the user must configure the DS3 and STS1/STS-3 circuitry to NOT share the same Serial Interface. ` 0 - Configures the STS-1/STS-3 and DS3 circuitry to NOT share the same Serial Interface. ` 1 - Configures the STS-1/STS-3 and DS3 circuitry to Share the same Serial Interface. BIT 5 - Additional T1/E1 Framer Enabled This READ/WRITE bit-field is used to either enable or disable the M13 T1/E1 Framers. If the user enables these additional T1/E1 Framers, then the XRT86SH328 will be able to perform full-blown performance monitoring in both the Ingress and Egress Directions .If the user disables the M13 T1/E1 Framers, then the user will only be able to perform full-block performance monitoring on the Ingress Direction T1/E1 signals. ` 0 - Disables the M13 T1/E1 Framer blocks. ` 1 - Enables the M13 T1/E1 Framer blocks. NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in the 28-Channel Clear-Channel T1/E1 Framer Mode. BIT [4:1] - Unused BIT 0 - AU-3/TUG-3 Mode Select: This READ/WRITE bit-field is used to configure the XRT86SH328 to operate in either the AU-3 or the TUG-3 Mapping Mode. ` 0 - Configures the XRT86SH328 to operate in the TUG-3 Mode. ` 1 - Configures the XRT86SH328 to operate in the AU-3 Mode. NOTE: This register bit is only active if the XRT86SH328 has been configured to operate in the SDH Mode. TABLE 39: LOOP-BACK CONTROL REGISTER - BYTE 0 (ADDRESS = 0X001F) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 Loop-back[3:0] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4]- Unused BIT [3:0] - Loop-back Mode[3:0] 51 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 These four READ/WRITE bits-fields are used to configure the XRT86SH328 to operate in a variety of loop-back modes, as is tabulated below. Loop Back Modes LOOP-BACK[3:0] RESULTING LOOP-BACK MODE 0000 Normal Mode (e.g., No Loop-back Mode) 0001 Remote Line Loop-back In this mode, all data that is received by the Receive STS-1/STS-3 Serial Interface will be routed to the Transmit STS-1/STS-3 Serial Interface. 0010 Local Transport Loop-back In this mode, all data that is being output via the Transmit STS-1/STS-3 TOH Processor block will also be routed to the Receive STS-1/STS-3 TOH Processor block. 0011 Local Path Loop-back In this mode, all data that is output by the Transmit STS-1/STS-3 POH Processor block (e.g., towards the Transmit STS-1/STS-3 TOH Processor block) will be routed to the Receive STS-1/STS-3 POH Processor block. 0100 - 1111 Reserved - Do Not Use TABLE 40: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 3 (ADDRESS = 0X0034) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 HRSYNC_Delay[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit STS-1/STS-3 Telecom Bus - Sync Delay - Upper Byte The Transmit STS-1/STS-3 Telecom Bus can be configured to alignment its transmission of SONET/SDH frames with 8kHz pulses being applied to the TxSBFP_IN_OUT input pin. The user is expected to apply a pulse (with the period of either a 6.48MHz or a 19.44MHz clock signal) at a rate of 8kHz to the TxSBFP_IN_OUT input (pin number P5). The Transmit STS-1/STS-3 Telecom Bus will align its transmission of the very first byte of a new STS-1/STS-3 frame, with a pulse at this input pin. These READ/WRITE bit-fields (along with that within the STS-1/STS-3 Telecom Bus Control Register - Byte 2) are used to specify the amount of delay (in terms of either 6.48MHz or 19.44MHz clock periods) that will exist between the rising edge of TxSBFP_IN_OUT and the transmission of the very first byte, within a given STS-1/STS-3 frame via the Transmit STS-1/STS-3 Telecom Bus. ` 0x0000 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to transmit the very first byte of a new STS-1/STS-3 frame, upon detection of the rising edge of the TxSBFP_IN_OUT. ` 0x0001 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to delay its transmission of the very first byte of a new STS-1/STS-3 frame, by one 6.48MHz or 19.44MHz clock period, and so on. NOTE: This register is only active if the STS-1/STS-3 Telecom Bus Interface is enabled. TABLE 41: STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0035) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 HRSYNC_Delay[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 52 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT [7:0] - Transmit STS-1/STS-3 Telecom Bus - Sync Delay - Lower Byte The Transmit STS-1/STS-3 Telecom Bus is aligned to the TxSBFP_IN_OUT input pin. The user is expected to apply a pulse (with the period of either a 6.48MHz or a 19.44MHz clock signal) at a rate of 8kHz to the TxSBFP_IN_OUT input (pin number P5). The Transmit STS-1/STS-3 Telecom Bus will align its transmission of the very first byte of a new STS1/STS-3 frame, with a pulse at this input pin. These READ/WRITE bit-fields (along with that within the STS-1/STS-3 Telecom Bus Control Register - Byte 3) are used to specify the amount of delay (in terms of either a 6.48MHz or a 19.44MHz clock periods) that will exist between the rising edge of TxSBFP_IN_OUT and the transmission of the very first byte, within a given STS-1/STS-3 frame via the Transmit STS-1/STS-3 Telecom Bus. ` 0x0000 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to transmit the very first byte of a new STS-1/STS-3 frame, upon detection of the rising edge of the TxSBFP_IN_OUT. S ` 0x0001 - Configures each of the Transmit STS-1/STS-3 Telecom Bus Interfaces to delay its transmission of the very first byte of a new STS-1/STS-3 frame, by one 6.48MHz or 19.44MHz clock period, and so on. NOTE: This register is only active if the STS-1/STS-3 Telecom Bus Interface is enabled. TABLE 42: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Set Telecom Bus to STS1/STS-3 Mode Fractional Bandwidth Enable Slot_0 Master R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Slot[1:0] BIT 2 Telecom Bus Parity Include V1 Signal BIT 1 BIT 0 Framing Telecom Bus Pulse Enable - V1 Signal Support Enable BIT 7 - Set Telecom Bus to STS-1/STS-3 Mode: This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate at either the STS1/STS-3 or STS-3 rates. ` .0 - Configures the Telecom Bus Interface to operate at the STS-3/STS-1/STS-3 rate. In this case, the Telecom Bus Interface will operate at a rate of 19.44MHz. ` 1 - Configures the Telecom Bus Interface to operate at the STS-1/STS-3 rate. In this case, the Telecom Bus Interface will operate with a clock rate of 6.48MHz. NOTE: This bit-field is only active if the XRT86SH328 has been configured to transmit/receive data (on the high-speed side) via the Telecom Bus Interface. BIT 6 - Fractional Bandwidth Enable: If the XRT86SH328 is configured to transmit/receive data via the Telecom Bus Interface as STS-3/STS-1/STS-3 rates, then this READ/WRITE bit-field can be used to configure the XRT86SH328 to operate in the Fractional Bandwidth Mode. If the XRT86SH328 is configured to operate in the Fractional Bandwidth Mode, then it will only fill in the STS-1/STS-3 time-slot data (within this outbound STS-3/STS-1 or STS-3 Data-stream) that pertains to this particular XRT86SH328. The XRT86SH328 will tri-state the Transmit STS-1/STS-3 Telecom bus interface coincident to whenever the other STS1/STS-3 time-slot data would ordinarily be output via the STS-3/STS-1/STS-3 Telecom Bus Interface. If the XRT86SH328 is NOT configured to operate in the Fractional Bandwidth Mode, then it will fill in the STS-1/STS-3 time-slot data (within this outbound STS-3/STS-1/STS-3 data-stream) that pertains to this particular XRT86SH328. The XRT86SH328 will automatically set the bytes (within all of the remaining STS-1/STS-3 time-slots) to 0x00 as it outputs this STS-3/STS-1/STS-3 data-stream via the Transmit STS-3/STS-1/STS-3 Telecom Bus Interface. ` 0 - Configures the XRT86SH328 to NOT operate in the Fractional Bandwidth Mode. ` 1 - Configures the XRT86SH328 to operate in the Fractional Bandwidth Mode. NOTES: 1. If the user wishes to design in three (3) XRT86SH328s (into his/her system) such that they are sharing the same STS-3/STS-1/STS-3 Telecom Bus, then the user must set this bit-field to 1. 53 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 2. This bit-field is only active if the Telecom Bus Interface has been configured to operate in the STS3/STS-1/STS-3 Mode. BIT 5 - Slot Master Designate This READ/WRITE bit-field is used to designate a given XRT86SH328 as being the Slot Master. If the user designates a given XRT86SH328 has being the Slot Master, then this device will be responsible for sourcing the B1 byte, the REIL and RDI-L indicators (within the outbound STS-3/STS-1/STS-3 data-stream). Additionally, if a given XRT86SH328 has been designated as the Slot Master, then it will be responsible for generating an 8kHz signal via its TxSBFP_IN_OUT input/output pin. If a given XRT86SH328 is NOT configured to function as the Slot Master, then its TxSBFP_IN_OUT input/output pin will function as an input pin ` 0 - Configures this particular XRT86SH328 to NOT be the Slot Master. ` 1 - Configures this particular XRT86SH328 to function as the Slot Master. NOTES: 1. This bit-field is only value if (1) the Telecom Bus Interface is configured to operate in the STS-3/STS1/STS-3 Mode. 2. The XRT86SH328 has been configured to operate in the Fractional Bandwidth Mode. 3. This particular XRT86SH328 has been assigned the STS-1/STS-3 Time Slot of [0, 0]. BIT [4:3] STS-1/STS-3 Time Slot Assignment: This READ/WRITE bit-field is used to specify which STS-1/STS-3 Time-slot that the XRT86SH328 will fill-in, if it has been configured to operate in the Fractional Bandwidth Mode. ` Valid values to write into these bit-fields are: [0, 0], [0, 1], and [1, 0]. NOTES: 1. These bit-fields are only active if (1) the Telecom Bus Interface has been configured to operate in the STS-3/STS-1/STS-3 Mode, and (2) if the user has configured the XRT86SH328 to operate in the Fractional Bandwidth Mode. 2. If a given XRT86SH328 has been designed into a given STS-3/STS-1/STS-3 application (which involves a total of three XRT86SH328s), for the XRT86SH328 (which has been designated as the Slot Master), the user MUST set these bit-fields to [0, 0]. BIT2 - Telecom Bus Parity Include V1 Signal BIT 1 - Telecom Bus Interface - Frame Pulse Mode: This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode. If the STS-1/STS-3 Telecom Bus Interface is configured to operate in the Frame Pulse Mode, then all of the following will be true. • The TxA_C1J1V1_FP output pin will only pulse high coincident to whenever the XRT86SH328 outputs the very first byte of a given STS-1/STS-3 frame via the Transmit STS-1/STS-3 Telecom Bus Interface - Output Data Bus (TxA_D[7:0]). • The RxD_C1J1V1_FP input pin will accept a pulse, coincident to whenever the very first byte of the incoming STS-1/STS-3 frame is being placed on the Receive STS-1/STS-3 Telecom Bus Interface - Input Data Bus (RxD_D[7:0]). If the STS-1/STS-3 Telecom Bus Interface is NOT configured to operate in the Frame Pulse Mode, then the Telecom Bus Interface will perform as configured in Bits 0 (Telecom Bus - V1 Signal Support Enable) within this register, and Bit 3 (Telecom Bus J1 Only) within the STS-3/STS-1/STS-3 Telecom Bus Control Register - Byte 0.0 - Configures the STS1/STS-3 Telecom Bus Interface to NOT operate in the Frame Pulse Mode.1 - Configures the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode. BIT - 0 - Transmit STS-1/STS-3 Telecom Bus - V1 Pulse Enable: This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 Telecom Bus Interface to pulse the TxA_C1J1V1_FP output pin HIGH coincident to whenever the XRT86SH328 outputs a V1 byte via the Transmit STS1/STS-3 Telecom Bus Interface - Output Data Bus (TxA_D[7:0]). ` 0 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to NOT denote the V1 byte via the TxA_C1J1V1_FP output pin. ` 1 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to denote the V1 byte via the TxA_C1J1V1_FP output pin. 54 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 NOTE: XRT86SH328 This register bit is only active if the XRT86SH328 has been configured to VT/TU map T1/E1 data into SONET/SDH. TABLE 43: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0036) BIT7 BIT6 BIT 5 BIT 4 Set Telecom Bus to STS-1/STS3 Mode Fractional Bandwidth Enable Slot_0 Master R/W R/W R/W R/W 0 0 0 0 BIT 3 BIT 2 BIT 1 BIT 0 Telecom Bus Parity Include V1 Signal Framing Pulse Enable Telecom Bus - V1 Signa Support Enable R/W R/W R/W R/W 0 0 0 0 Slot[1:0] BIT 7 - Set Telecom Bus to STS-1/STS-3 Mode This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate at either the STS1/STS-3 or STS-3 rates. ` 0 - Configures the Telecom Bus Interface to operate at the STS-3/STS-3 rate. In this case, the Telecom Bus Interface will operate at a rate of 19.44MHz. ` 1 - Configures the Telecom Bus Interface to operate at the STS-1/STS-3 rate. In this case, the Telecom Bus Interface will operate with a clock rate of 6.48MHz. NOTE: This bit-field is only active if the XRT86SH328 has been configured to transmit/receive data (on the high-speed side) via the Telecom Bus Interface. BIT 6 - Fractional Bandwidth Enable If the XRT86SH328 is configured to transmit/receive data via the Telecom Bus Interface as STS-3/STS-1/STS-3 rates, then this READ/WRITE bit-field is used to configure the XRT86SH328 to operate in the Fractional Bandwidth Mode. If the user configures the XRT86SH328 to operate in the Fractional Bandwidth Mode, then it will only fill in the STS1/STS-3 time-slot data (within this outbound STS-3/STS-1/STS-3 data-stream) that pertains to this particular XRT86SH328. The XRT86SH328 will tri-state the Transmit STS-1/STS-3 Telecom bus interface coincident to whenever the other STS-1/STS-3 time-slot data would ordinarily be output via the STS-3/STS-1/STS-3 Telecom Bus Interface. If the user configures the XRT86SH328 to NOT operate in the Fractional Bandwidth Mode, then it will fill in the STS1/STS-3 time-slot data (within this outbound STS-3/STS-1/STS-3 data-stream) that pertains to this particular XRT86SH328. The XRT86SH328 will automatically set the bytes (within all of the remaining STS-1/STS-3 time-slots) to 0x00 as it outputs this STS-3/STS-1/STS-3 data-stream via the Transmit STS-3/STS-1/STS-3 Telecom Bus Interface. ` 0 - Configures the XRT86SH328 to NOT operate in the Fractional Bandwidth Mode. ` 1 - Configures the XRT86SH328 to operate in the Fractional Bandwidth Mode. NOTES: 1. To design in three (3) XRT86SH328s (into the users system) such that they are sharing the same STS3/STS-1/STS-3 Telecom Bus, then the user must set this bit-field to 1. 2. This bit-field is only active if the Telecom Bus Interface has been configured to operate in the STS3/STS-1/STS-3 Mode. BIT 5 - Slot 0 Master Designate This READ/WRITE bit-field is used to designate a given XRT86SH328 as being the Slot Master. If the user designates a given XRT86SH328 has being the Slot Master, then this device will be responsible for sourcing the B1 byte, the REIL and RDI-L indicators (within the outbound STS-3/STS-1/STS-3 data-stream). Additionally, if a given XRT86SH328 has been designated as the Slot Master, then it will be responsible for generating an 8kHz signal via its TxSBFP_IN_OUT input/output pin. If a given XRT86SH328 is NOT configured to function as the Slot Master, then its TxSBFP_IN_OUT input/output pin will function as an input pin. ` 0 - Configures this particular XRT86SH328 to NOT be the Slot Master. 55 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 1 - Configures this particular XRT86SH328 to function as the Slot Master. NOTES: 1. This bit-field is only value if (1) the Telecom Bus Interface is configured to operate in the STS-3/STS1/STS-3 Mode. 2. The XRT86SH328 has been configured to operate in the Fractional Bandwidth Mode. 3. This particular XRT86SH328 has been assigned the STS-1/STS-3 Time Slot of [0, 0]. BIT [4:3] - STS-1/STS-3 Time Slot Assignmen This READ/WRITE bit-field is used to specify which STS-1/STS-3 Time-slot that the XRT86SH328 will fill-in, if it has been configured to operate in the Fractional Bandwidth Mode. Valid values to write into these bit-fields are: [0, 0], [0, 1], and [1, 0]. NOTES: 1. These bit-fields are only active if (1) the Telecom Bus Interface has been configured to operate in the STS-3/STS-1/STS-3 Mode, and (2) if the user has configured the XRT86SH328 to operate in the Fractional Bandwidth Mode.2. 2. If a given XRT86SH328 has been designed into a given STS-3/STS-1/STS-3 application (which involves a total of three XRT86SH328s), for the XRT86SH328 (which has been designated as the Slot Master), the user MUST set these bit-fields to [0, 0]. BIT 2 - Telecom Bus Parity Include V1 Signal BIT 1 - .Telecom Bus Interface - Frame Pulse Mode This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode. If the user configures the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode, then all of the following will be true. • The TxA_C1J1V1_FP output pin will only pulse high coincident to whenever the XRT86SH328 outputs the very first byte of a given STS-1/STS-3 frame via the Transmit STS-1/STS-3 Telecom Bus Interface - Output Data Bus (TxA_D[7:0]) • The RxD_C1J1V1_FP input pin will accept a pulse, coincident to whenever the very first byte of the incoming STS-1/STS-3 frame is being placed on the Receive STS-1/STS-3 Telecom Bus Interface - Input Data Bus (RxD_D[7:0]). If the user does NOT configure the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode, then the Telecom Bus Interface will perform as configured in Bits 0 (Telecom Bus - V1 Signal Support Enable) within this register, and BIT 3 (Telecom Bus J1 Only) within the STS-3/STS-1/STS-3 Telecom Bus Control Register - Byte 0. ` 0 - Configures the STS-1/STS-3 Telecom Bus Interface to NOT operate in the Frame Pulse Mode ` 1 - Configures the STS-1/STS-3 Telecom Bus Interface to operate in the Frame Pulse Mode BIT 0 - Transmit STS-1/STS-3 Telecom Bus - V1 Pulse Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 Telecom Bus Interface to pulse the TxA_C1J1V1_FP output pin HIGH coincident to whenever the XRT86SH328 outputs a V1 byte via the Transmit STS1/STS-3 Telecom Bus Interface - Output Data Bus (TxA_D[7:0]) ` .0 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to NOT denote the V1 byte via the TxA_C1J1V1_FP output pin. ` 1 - Configures the Transmit STS-1/STS-3 Telecom Bus Interface to denote the V1 byte via the TxA_C1J1V1_FP output pin. NOTE: This register bit is only active if the XRT86SH328 has been configured to VT/TU map T1/E1 data into SONET/SDH. 56 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 44: STS-3/STS-1/STS-3 TELECOM BUS CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0037) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Telecom Bus ON Telecom Bus Disable Unused Telecom Bus Parity Type Telecom Bus J1 Only Telecom Bus Parity Odd Telecom Bus Parity Enable Rephase STS-1 R/W R/W R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 1 BIT 7 - Telecom Bus Enable This READ/WRITE is used to either enable or disable the 51.84/155.52Mbps Telecom Bus Interface. ` 0 - Telecom Bus Interface is Disabled:STS-1/STS-3 data will output via the STS-1/STS-3 Serial Interface. ` 1 - Telecom Bus Interface is Enabled:In this selection, both the Transmit and Receive STS-1/STS-3 Telecom Bus Interfaces will be enabled. BIT 6 - Telecom Bus Tri-state This READ/WRITE bit-field is used to tri-state the Telecom Bus Interface. ` 0 - Telecom Bus Interface is NOT tri-stated. ` 1 - Telecom Bus Interface is tri-stated. NOTE: This READ/WRITE bit-field is ignored if the STS-1/STS- 3 Transmit and Receive STS-1/STS-3 Telecom Bus Interfaces are disabled. BIT 5 - Unused BIT 4- Telecom Bus Parity Type This READ/WRITE bit-field is used to define the parameters, over which Telecom Bus parity will be computed. ` 0 - Parity is computed/verified over the Transmit STS-1/STS-3 and Receive Telecom Bus - data bus pins (e.g., TXA_D[7:0] and RXD_D[7:0]).If the user implements this selection, then the following will happen. a. The Transmit STS-1/STS-3 Telecom Bus Interface will compute and output parity (via the TXA_DP output pin) based upon and coincident with the data being output via the TXA_D[7:0] output pins. b. The STS-1/STS-3 Receive Telecom Bus Interface will compute and verify the parity data (which is input via the RXD_DP input pin) based upon the data which is being input (and latched) via the RXD_D[7:0] input pins. ` 1 - Parity is computed/verified over the Transmit STS-1/STS-3 and Receive Telecom Bus - data bus pins (e.g., TXA_D[7:0] and RXD_D[7:0]), the C1J1 and PL input/output pins. ` If the user implements this selection, then the following will happen. a. The Transmit STS-1/STS-3 Telecom Bus Interface will compute and output parity (via the TXA_DP output) based upon and coincident with (1) the data being output via the TXA_D[7:0] output pins, (2) the state of the TXA_PL output pin, and (3) the state of the TXA_C1J1 output pin. b. The Receive STS-1/STS-3 Telecom Bus Interface will compute and verify the parity data (which is input via the RXD_DP input pin) based upon (1) the data which is being input (and latched) via the RXD_D[7:0] input pins, (2) the state of the RXD_PL input pin, and (3) the state of the RXD_C1J1 input pin. NOTES: 1. This bit-field is disabled if the STS-1/STS-3 Telecom Bus is disabled. 2. The user can configure the STS-1/STS-3 Telecom Bus to compute with either even or odd parity, by writing the appropriate data into BIT 2 (Telecom Bus Parity - Odd), within this register. BIT 3 - Telecom Bus - J1 Indicator Only: This READ/WRITE bit-field is used to configure how the Transmit STS-1/STS-3 and Receive Telecom Bus interface handles the TXA_C1J1 and RXD_C1J1 signals, as described below. ` 0 - C1 and J1 Bytes This selection configures the following. a. The Transmit STS-1/STS-3 Telecom Bus to pulse the TXA_C1J1V1_FP output coincident to whenever the C1 and J1 bytes are being output via the TXA_D[7:0] output pins. 57 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 b. The STS-1/STS-3 Receive Telecom Bus will expect the RXD_C1J1V1_FP input to pulse high coincident to whenever the C1 and J1 bytes are being sampled via the RXD_D[7:0] input pins. ` 1 - J1 Bytes Only This selection configures the following. a. The Transmit STS-1/STS-3 Telecom Bus Interface to only pulse the TXA_C1J1V1_FP output pin coincident to whenever the J1 byte is being output via the TXA_D[7:0] output pins. NOTE: The TXA_C1J1V1_FP output pin will NOT be pulsed high whenever the C1 byte is being output via the TXA_D[7:0] output pins. b. NOTE: The STS-1/STS-3 Receive Telecom Bus Interface will expect the RXD_C1J1V1_FP input to only pulse high coincident to whenever the J1 byte is being sampled via the RXD_D[7:0] input pins. The RXD_C1J1V1_FP input pin will NOT be pulsed high whenever the C1 byte is being input via the RXD_D[7:0] input pins BIT 2 - Telecom Bus Parity - ODD Parity Select: This READ/WRITE bit-field is used to configure the STS-1/STS-3 Telecom Bus Interface to do the following. a. In the Transmit (Drop) DirectionThe STS-1/STS-3 Telecom Bus to compute either the EVEN or ODD parity over the contents of the (1) TxD_D[7:0] output pins, or (2) TxD_D[7:0] output pins, the states of the TxD_PL and TxD_C1J1 output pins (depending upon user setting for BIT 3). b. In the Receive (Add) DirectionReceive STS-1/STS-3 Telecom Bus to compute and verify the EVEN or ODD parity over the contents of the (1) RxA_D[7:0] input pins, or (2) RxA_D[7:0] input pins, the states of the RxA_PL and RxA_C1J1 input pins (depending upon user setting for BIT 3). ` 0 - Configures Transmit (Drop) Telecom Bus to compute EVEN parity and configures the Receive (Add) Telecom Bus to verify EVEN parity. ` 1 - Configures Transmit (Drop) Telecom Bus to compute ODD parity and configures the Receive (Add) Telecom Bus to verify ODD parity. BIT 1 - Telecom Bus Parity Enable This READ/WRITE bit-field is used to either enable or disable parity calculation and placement via the TxA_DP output pin. This bit field also is used to enable or disable parity verification by the Receive Telecom Bus. ` 0 - Disables Parity Calculation (on the Transmit Telecom Bus) and Disables Parity Verification (on the Receive Telecom Bus. ` 1 - Enables Parity Calculation and Verification BIT 0 - Telecom Bus - Rephase Enable This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 Telecom Bus to operate in either the Rephase ON or Rephase OFF Modes. If the user configures the Receive STS-1/STS-3 Telecom Bus Interface to operate on the Rephase ON Mode, then the Receive STS-1/STS-3/STS-1/STS-3 TOH/POH Processor blocks will internally compute the Pointer Bytes, based upon the data that it receives via the RxD_D[7:0] input pins. If the user configures the Receive STS-1/STS-3 Telecom Bus Interface to operate in the Rephase OFF Mode, then the Receive STS-1/STS-3/STS-1/STS-3 TOH/POH Processor blocks will NOT internally compute the Pointer Bytes, based upon the data that it receives via the RxD_D[7:0] input pins. In this case, the Voyager device will rely upon the signaling via the Telecom Bus Interface pins (e.g., via the RxD_PL and RxD_C1J1V1_FP pins) in order to compute these pointer bytes. NOTE: If the Receive STS-1/STS-3 Telecom Bus is being provided with pulses denoting the C1 and J1 bytes (via the RxD_C1J1V1_FP input pin), then this feature is unnecessary. ` 0 - Configures the Telecom Bus Interface to operate in the Rephase OFF Mode. ` 1 - Configures the Telecom Bus Interface to operate in the Rephase ON Mode. 58 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 45: OPERATION BLOCK - INTERFACE CONTROL REGISTER (ADDRESS = 0X003C) BIT7 BIT6 BIT 5 Unused BIT 4 BIT 3 Telecom Bus Parity Error Interrupt Status BIT 2 BIT 1 Unused BIT 0 Telecom Bus Parity Error Interrupt Enable R/O R/O R/O RUR R/O R/O R/O R/W 0 0 0 0 0 0 0 0 BIT [7:5] - Unused BIT 4- Telecom Bus Interface - Detection of Parity Error Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Receive STS-1/STS-3 Telecom Bus Interface has detected a parity error within the incoming STS-1/STS-3 data-stream since the last read of this register, as described below. ` 0 - Indicates that the Receive STS-1/STS-3 Telecom Bus Interface has NOT detected a parity error since the last read of this register. ` 1 - Indicates that the Receive STS-1/STS-3 Telecom Bus Interface has detected a parity error (and has generated the Detection of Parity Error interrupt) since the last read of this register. NOTE: This register bit-field is only active if the XRT86SH328 has been configured to exchange STS-1/STS-3 data via the Telecom Bus Interface. BIT [3:1] - Unused BIT 0 - Telecom Bus Interface - Detection of Parity Error Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Receive STS-1/STS-3 Telecom Bus Interface Detection of Parity Error interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 Telecom Bus Interface will generate this interrupt anytime it detects a parity error within the incoming STS-1/STS-3 data-stream. ` 0 - Disables the Receive STS-1/STS-3 Telecom Bus Interface - Detection of Parity Error interrupt. ` 1 - Enables the Receive STS-1/STS-3 Telecom Bus Interface - Detection of Parity Error interrupt. TABLE 46: OPERATION GENERAL PURPOSE INPUT/OUTPUT REGISTER - BYTE 0 (ADDRESS = 0X0047) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 GPIO_7 GPIO_6 GPIO_5 GPIO_4 GPIO_3 GPIO_2 GPIO_1 GPIO_0 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits [7:0] - General Purpose Input/Output Pin # 7 thru 0 The function of this READ/WRITE bit-field depends upon whether the GPIO_[7:0] pins are configured to be an input or an output pin. If GPIO_[7:0] is configured to be an input pin: These register bits operates as a READ-ONLY bit-fields that reflects the state of the GPIO_[7:0] input pins. If the GPIO_[7:0] input pins are pulled to a logic HIGH, then this register bit will be set to 1. Conversely, if the GPIO_7 input pin is pulled to a logic LOW, then this register bit will be set to 0. If GPIO_[7:0] is configured to be an output pin Tthe user can control the logic level of GPIO_[7:0] by writing the appropriate value into these bit-fields. ` 0 - Causes the GPIO_[7:0] output pins to be driven LOW. ` 1 - Causes the GPIO_[7:0] output pins to be driven HIGH. 59 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 47: OPERATION GENERAL PURPOSE INPUT/OUTPUT DIRECTION REGISTER 0 (ADDRESS = 0X004B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 GPIO_DIR[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - GPIO_[7:0] Direction Select These READ/WRITE bit-fields are used to configure the GPIO_[7:0] pins to function as either input or output pins. ` 0 - Configures GPIO_[7:0] to function as input pins. ` 1 - Configures GPIO_[7:0] to function as output pins. TABLE 48: OPERATION I/O CONTROL REGISTER (ADDRESS = 0X004F) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 RxCLK_Select[4:0] R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:5] - Unused BIT [4:0] - Recovered T1/E1 Clock Select[4:0] These READ/WRITE bit-fields are used to select any one of 28 T1 or 21 E1 Recovered Clock signals, and do either of the following.· Output a replica of this selected clock signal via the RCLKOUT output pins.· Synthesize a 19.44MHz clock signal (from this selected Recovered T1/E1 Clock) and output this signal via the RCLKOUT output pin. The relationship between the contents within these bit-fields and the selected channel is tabulated below. Bit Field Contents RXCLK_SELECT[4:0] SELECTED CHANNEL 00000 NONE 00001 Channel 0 00010 Channel 1 00011 Channel 2 00100 Channel 3 00101 Channel 4 00110 Channel 5 00111 Channel 6 01000 Channel 7 01001 Channel 8 01010 Channel 9 01011 Channel 10 COMMENT RCLKOUT pin is tri-stated 60 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Bit Field Contents RXCLK_SELECT[4:0] SELECTED CHANNEL 01100 Channel 11 01101 Channel 12 01110 Channel 13 01111 Channel 14 10000 Channel 15 10001 Channel 16 10010 Channel 17 10011 Channel 18 10100 Channel 19 10101 Channel 20 10110 Channel 21 10111 Channel 22 11000 Channel 23 11001 Channel 24 11010 Channel 25 11011 Channel 26 11100 Channel 27 11101 NONE RCLKOUT is an Input pin 11110 NONE RCLKOUT is an Input Pin 11111 NONE RCLKOUT is an Input Pin COMMENT TABLE 49: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0050) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer VT-Side Channel 27 DS1/E1 Framer VT-Side Channel 26 DS1/E1 Framer VT-Side Channel 25 DS1/E1 Framer VT-Side Channel 24 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:4]- Unused BIT [3:0] - DS1/E1 Framer Block (VT Side) Channels 27, 26, 25 & 24 These READ-ONLY bit-fields indicate whether or not the DS1/E1 Framer block (on the VT Side) associated with Channel [27:24] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer block sassociated with Channel [27:24] (on the VT Side) does NOT have a 61 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [27:24] (on the VT side) DOES have a pending interrupt request. TABLE 50: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0051) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer VT-Side Channel 23 DS1/E1 Framer VT-Side Channel 22 DS1/E1 Framer VT-Side Channel 21 DS1/E1 Framer VTSide Channel 20 DS1/E1 Framer VT-Side Channel 19 DS1/E1 Framer VT-Side Channel 18 DS1/E1 Framer VT-Side Channel 17 DS1/E1 Framer VT-Side Channel 16 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - DS1/E1 Framer Block (VT Side) Channels [23:16] These READ-ONLY bit-field indicates whether or not the DS1/E1 Framer block (on the VT Side) associated with Channel [23:16] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer blocks associated with Channel [23:16] (on the VT Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [23:16] (on the VT side) DOES have a pending interrupt request. TABLE 51: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0052) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer VT-Side Channel 15 DS1/E1 Framer VT-Side Channel 14 DS1/E1 Framer VT-Side Channel 13 DS1/E1 Framer VT-Side Channel 12 DS1/E1 Framer VT-Side Channel 11 DS1/E1 Framer VT-Side Channel 10 DS1/E1 Framer VT-Side Channel 9 DS1/E1 Framer VT-Side Channel 8 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - DS1/E1 Framer Block (VT Side) Channels [15:8] These READ-ONLY bit-field indicates whether or not the DS1/E1 Framer block (on the VT Side) associated with Channel [15:8] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer blocks associated with Channel [15:8] (on the VT Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [15:8] (on the VT side) DOES have a pending interrupt request. 62 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 52: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (VT SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0053) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer VT-Side Channel 7 DS1/E1 Framer VT-Side Channel 6 DS1/E1 Framer VT-Side Channel 5 DS1/E1 Framer VT-Side Channel 4 DS1/E1 Framer VT-Side Channel 3 DS1/E1 Framer VT-Side Channel 2 DS1/E1 Framer VT-Side Channel 1 DS1/E1 Framer VT-Side Channel 0 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - DS1/E1 Framer Block (VT Side) Channels [7:0] These READ-ONLY bit-field indicates whether or not the DS1/E1 Framer block (on the VT Side) associated with Channel [7:0] has a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer blocks associated with Channel [7:0] (on the VT Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer blocks associated with Channel [7:0] (on the VT side) DOES have a pending interrupt request. TABLE 53: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0054) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer M13-Side Channel 27 DS1/E1 Framer M13-Side Channel 26 DS1/E1 Framer M13-Side Channel 25 DS1/E1 Framer M13-Side Channel 24 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - BIT 4 - Unused BIT [3:0] - DS1/E1 Framer Block (M13 Side) Channels [27:24] These READ-ONLY bit-field indicate whether or not the DS1/E1 Framer block (on the M13 Side) associated with Channel [27:24] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer block associated with Channel [27:24] (on the M13 Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer block associated with Channel [27:24] (on the M13 side) DOES have a pending interrupt request. TABLE 54: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0055) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer M13-Side Channel 23 DS1/E1 Framer M13-Side Channel 22 DS1/E1 Framer M13-Side Channel 21 DS1/E1 Framer M13-Side Channel 20 DS1/E1 Framer M13-Side Channel 19 DS1/E1 Framer M13-Side Channel 18 DS1/E1 Framer M13-Side Channel 17 DS1/E1 Framer M13-Side Channel 16 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 63 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT [7:0] - DS1/E1 Framer Block (M13 Side) Channel [23:16] These READ-ONLY bit-fields indicates whether or not the DS1/E1 Framer block (on the M13 Side) associated with Channel [23:16] has a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer block associated with Channel [23:16] (on the M13 Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer block associated with Channel [23:16] (on the M13 side) DOES have a pending interrupt request. TABLE 55: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0056) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 Framer M13-Side Channel 15 DS1/E1 Framer M13-Side Channel 14 DS1/E1 Framer M13-Side Channel 13 DS1/E1 Framer M13-Side Channel 12 DS1/E1 Framer M13-Side Channel 11 DS1/E1 Framer M13-Side Channel 10 DS1/E1 Framer M13-Side Channel 9 DS1/E1 Framer M13-Side Channel 8 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - DS1/E1 Framer Block (M13 Side) Channels [15:8] These READ-ONLY bit-fields indicate whether or not the DS1/E1 Framer block (on the M13 Side) associated with Channels [15:8] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer block associated with Channel [15:8] (on the M13 Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer block associated with Channel [15:8] (on the M13 side) DOES have a pending interrupt request. TABLE 56: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 FRAMER (M13 SIDE) BLOCK - BYTE 3 (ADDRESS = 0X0057) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 DS1/E1 DS1/E1 DS1/E1 DS1/E1 DS1/E1 DS1/E1 DS1/E1 Framer M13- Framer M13- Framer M13- Framer M13- Framer M13- Framer M13- Framer M13- Framer M13Side ChanSide ChanSide ChanSide ChanSide ChanSide ChanSide ChanSide Channel 7 nel 6 nel 5 nel 4 nel 3 nel 2 nel 1 nel 0 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - DS1/E1 Framer Block (M13 Side) Channels [7:0] These READ-ONLY bit-fields indicate whether or not the DS1/E1 Framer block (on the M13 Side) associated with Channels [7:0] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 Framer block associated with Channel [7:0] (on the M13 Side) does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 Framer block associated with Channel [7:0] (on the M13 side) DOES have a pending interrupt request. 64 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 57: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0058) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 LIU Channel 27 DS1/E1 LIU Channel 26 DS1/E1 LIU Channel 25 DS1/E1 LIU Channel 24 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT [3:0] - DS1/E1 LIU Block Channels [27:24] These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [27:24] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 LIU block associated with Channel [27:24] does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 LIU block associated with Channel [27:24] DOES have a pending interrupt request. TABLE 58: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X0059) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 LIU Channel 23 DS1/E1 LIU Channel 22 DS1/E1 LIU Channel 21 DS1/E1 LIU Channel 20 DS1/E1 LIU Channel 19 DS1/E1 LIU Channel 18 DS1/E1 LIU Channel 17 DS1/E1 LIU Channel 16 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 Bit[ 7:0] - DS1/E1 LIU Block Channels [23:16] These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [23:16] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 LIU block associated with Channel [23:16] does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 LIU block associated with Channel [23:16] DOES have a pending interrupt request. TABLE 59: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005A) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 LIU Channel 15 DS1/E1 LIU Channel 14 DS1/E1 LIU Channel 13 DS1/E1 LIU Channel 12 DS1/E1 LIU Channel 11 DS1/E1 LIU Channel 10 DS1/E1 LIU Channel 9 DS1/E1 LIU Channel 8 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 Bit [7:0] - DS1/E1 LIU Block Channel [15:8] These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [15:8] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 LIU block associated with Channel [15:8] does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 LIU block associated with Channel [15:8] DOES have a pending interrupt request. 65 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 60: CHANNEL INTERRUPT INDICATION REGISTER - DS1/E1 LIU BLOCK - BYTE 3 (ADDRESS = 0X005B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS1/E1 LIU Channel 7 DS1/E1 LIU Channel 6 DS1/E1 LIU Channel 5 DS1/E1 LIU Channel 4 DS1/E1 LIU Channel 3 DS1/E1 LIU Channel 2 DS1/E1 LIU Channel 1 DS1/E1 LIU Channel 0 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - DS1/E1 LIU Block Channels [7:0] These READ-ONLY bit-fields indicate whether or not the DS1/E1 LIU block associated with Channels [7:0] have a pending Interrupt Request. ` 0 - Indicates that the DS1/E1 LIU block associated with Channel [7:0] does NOT have a pending interrupt request. ` 1 - Indicates that the DS1/E1 LIU block associated with Channel [7:0] DOES have a pending interrupt request. TABLE 61: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005C) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 VT Mapper Block Channel 27 VT Mapper Block Channel 26 VT Mapper Block Channel 25 VT Mapper Block Channel 24 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:4] - Unused Bit [3:0] - VT-Mapper Block Channels [27:24] These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [27:24] have a pending Interrupt Request. ` 0 - Indicates that the VT-Mapper block associated with Channel [27:24] does NOT have a pending interrupt request. ` 1 - Indicates that the VT-Mapper block associated with Channel [27:24] DOES have a pending interrupt request. TABLE 62: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005D) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 VT-Mapper Channel 23 VT-Mapper Channel 22 VT-Mapper Channel 21 VT-Mapper Channel 20 VT-Mapper Channel 19 VT-Mapper Channel 18 VT-Mapper Channel 17 VT-Mapper Channel 16 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - VT-Mapper Block Channels [23:16] These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [23:16] have a pending Interrupt Request. ` 0 - Indicates that the VT-Mapper block associated with Channel [23:16] does NOT have a pending interrupt request. ` 1 - Indicates that the VT-Mapper block associated with Channel [23:16] DOES have a pending interrupt request. 66 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 63: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005E) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 VT-Mapper Channel 15 VT-Mapper Channel 14 VT-Mapper Channel 13 VT-Mapper Channel 12 VT-Mapper Channel 11 VT-Mapper Channel 10 VT-Mapper Channel 9 VT-Mapper Channel 8 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - VT-Mapper Block Channels [15:8] These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [15:8] have a pending Interrupt Request. ` 0 - Indicates that the VT-Mapper block associated with Channel [15:8] does NOT have a pending interrupt request. ` 1 - Indicates that the VT-Mapper block associated with Channel [15:8] DOES have a pending interrupt request. TABLE 64: CHANNEL INTERRUPT INDICATION REGISTER - VT-MAPPER BLOCK - BYTE 3 (ADDRESS = 0X005F) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 VT-Mapper Channel 7 VT-Mapper Channel 6 VT-Mapper Channel 5 VT-Mapper Channel 4 VT-Mapper Channel 3 VT-Mapper Channel 2 VT-Mapper Channel 1 VT-Mapper Channel 0 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 Bit[ 7:0] - VT-Mapper Block Channels [7:0] These READ-ONLY bit-fields indicate whether or not the VT-Mapper block associated with Channels [7:0] have a pending Interrupt Request. ` 0 - Indicates that the VT-Mapper block associated with Channel [7:0] does NOT have a pending interrupt request. ` 1 - Indicates that the VT-Mapper block associated with Channel [7:0] DOES have a pending interrupt request. 2.2 LIU COMMON CONTROL REGISTERS TABLE 65: LIU COMMON CONTROL REGISTER 0 (ADDRESS = 0X0100) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Reserved ATAOS R/W R/W R/W R/W R/W 0 0 0 0 0 BIT 2 BIT 1 BIT 0 TCLKCNTL LIU Software RESET R/W R/W R/W 0 0 0 Reserved BIT 7 - Reserved: BIT 6 - ATAOS: Automatic Transmit All Ones Upon RLOS Condition If ATAOS is selected, an all ones pattern will be transmitted on any channel that experiences an RLOS condition. If an RLOS condition does not occur, TAOS will remain inactive. 0 = Disabled 1 = Enabled Bits [5:2] - Reserved: BIT 1 - TCLKCNTL If TCLKCNTL is selected, and if the transmit clock to the DS-1 framer is missing, Low, or High, then the transmitter outputs to the line interface will send an All Ones Signal. 0 = Disabled 67 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 1 = Enabled BIT 0 - LIU Software RESET: Writing a 1 to this bit for more than 10µS initiates a device reset for all internal circuits except the microprocessor register bits. To reset the registers to their default setting, use the Hardware Reset pin (See the pin description for more details) 0 = Disabled 1 = Enabled TABLE 66: LIU COMMON CONTROL REGISTER 1 (ADDRESS = 0X0101) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LCVB_OF PLL19_Dis Reserved Slicer Level Select[1:0] RXMUTE EXLOS ICT R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Line Code Violation / Counter Overflow Monitor Select This bit is used to select the monitoring activity between the LCV and the counter overflow status. When the 16-bit LCV counter saturates, the counter overflow condition is activated. By default, the LCV activity is monitored by bit D4 in register 0xN005, where N is equal to the channel number. ` 0 - Monitoring LCV ` 1 - Monitoring the counter overflow status BIT 6 - PLL 19.44MHz Disable This bit is used in conjunction with the DS-1/E1 recovered clock to synchronize to a 19.44MHz clock source. If this bit is set High, one of the 28 channel recovered line clocks, or an external line clock and be used to provide this synchronization. ` 0 - Disabled ` 1 - Enabled BIT 5 - Reserved BIT [4:3] - Slicer Level Select These bits are to used to select the amplitude level that is used by the receive line interface to determine whether the input data is High or Low. 00 - 50% 01 - 45% 10 - 55% 11 - 68% BIT 2 - RxMUTE This bit is used to force the receive DS-1/E1 signals Low to prevent chattering any time that the DS-1/E1 receiver inputs at Rtip/Rring experience an RLOS condition. ` 0 - Disabled ` 1 - Enabled BIT 1 - EXLOS The number of zeros required to declare a Digital Loss of Signal is extended to 4,096. ` 0 - Normal RLOS operation ` 1 - EXLOS enabled BIT 0 - In Circuit Testing For Internal use only. This bit should be set to Low. 68 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 67: LIU COMMON CONTROL REGISTER 2 (ADDRESS = 0X0102) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 CLKSEL[3:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Reserved BIT [3:0] - Input Clock Selection These bits are used to select the frequency of the input clock source to the PLL. Any state not listed is reserved. 0000 = 2.048 MHz 0001 = 1.544 MHz 1000 = 4.096 MHz 1001 = 3.088 MHz 1010 = 8.192 MHz 1011 = 6.176 MHz 1100 = 16.384 MHz 1101 = 12.352 MHz 1110 = 2.048 MHz 1111 = 1.544 MHz TABLE 68: LIU COMMON CONTROL REGISTER 3 (ADDRESS = 0X0103) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DS1/E1 LIU Global Interrupt Status Channel 6 DS1/E1 LIU Global Interrupt Status Channel 5 DS1/E1 LIU Global Interrupt Status Channel 4 DS1/E1 LIU Global Interrupt Status Channel 3 DS1/E1 LIU Global Interrupt Status Channel 2 DS1/E1 LIU Global Interrupt Status Channel 1 DS1/E1 LIU Global Interrupt Status Channel 0 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - Reserved BIT [6:0] - Global Channel Interrupt Status - Channels 0 to 6 These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register is read back, these bit fields will automatically return Low. 69 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 69: LIU COMMON CONTROL REGISTER 4 (ADDRESS = 0X0104) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DS1/E1 LIU Global nterrupt Status Channel 13 DS1/E1 LIU Global nterrupt Status Channel 12 DS1/E1 LIU Global nterrupt Status Channel 11 DS1/E1 LIU Global nterrupt Status Channel 10 DS1/E1 LIU Global nterrupt Status Channel 9 DS1/E1 LIU Global nterrupt Status Channel 8 DS1/E1 LIU Global nterrupt Status Channel 7 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - Reserved BIT [6:0] - Global Channel Interrupt Status - Channels 7 to 13 These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register is read back, these bit fields will automatically return Low. TABLE 70: LIU COMMON CONTROL REGISTER 5 (ADDRESS = 0X0105) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DS1/E1 LIU Global nterrupt Status Channel 20 DS1/E1 LIU Global nterrupt Status Channel 19 DS1/E1 LIU Global nterrupt Status Channel 18 DS1/E1 LIU Global nterrupt Status Channel 17 DS1/E1 LIU Global nterrupt Status Channel 16 DS1/E1 LIU Global nterrupt Status Channel 15 DS1/E1 LIU Global nterrupt Status Channel 14 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - Reserved BIT [6:0] - Global Channel Interrupt Status - Channels 14 to 20 These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register is read back, these bit fields will automatically return Low. TABLE 71: LIU COMMON CONTROL REGISTER 6 (ADDRESS = 0X0106) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DS1/E1 LIU Global Interrupt Status Channel 27 DS1/E1 LIU Global Interrupt Status Channel 26 DS1/E1 LIU Global Interrupt Status Channel 25 DS1/E1 LIU Global Interrupt Status Channel 24 DS1/E1 LIU Global Interrupt Status Channel 23 DS1/E1 LIU Global Interrupt Status Channel 22 DS1/E1 LIU Global Interrupt Status Channel 21 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - Reserved BIT [6:0] - Global Channel Interrupt Status - Channels 21 to 27 These RUR bit fields are used to indicate which channel experienced a change in status relative to alarm indications. If a channel experiences a change in alarm status, the associated bit for that channel will be set High. Once this register 70 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS is read back, these bit fields will automatically return Low. 2.3 RECEIVE STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS The register map for the Receive STS-1/STS-3 TOH Processor block is presented in the Table below. Additionally, a detailed description of each of the Receive STS-1/STS-3 TOH Processor Block registers is presented below. In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328, with the Receive STS-1/STS-3 TOH Processor Block highlighted is presented below in Figure 3. FIGURE 3. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 TABLE 72: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0202) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 Sync on B1 Unused No OH Extract R/O R/O R/O R/O R/O R/W R/O R/W 0 0 0 0 0 0 0 0 BIT [7:3] - Unused BIT 2 - Sync on B1 71 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT 1 - Unused BIT 0 - No Overhead Data Extract TABLE 73: RECEIVE STS-1/STS-3 TRANSPORT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0203) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused SF Defect Condition Detect Enable SD Defect Condition Detect Enable DescrambleDisable Unused REI-LError Type B2 ErrorType B1 Error Type R/O R/W R/W R/W R/O R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Unused BIT 6 - Signal Failure (SF) Defect Condition Detect Enable This READ/WRITE bit-field is used to enable or disable SF Defect Detection and Declaration by the Receive STS1/STS-3 TOH Processor block. ` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to NOT declare nor clear the SF defect condition per the user-specified SF defect declaration and clearance criteria. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to declare and clear the SF defect condition per the user-specified SF defect declaration and clearance criteria. BIT 5 - Signal Degrade (SD) Defect Condition Detect Enable This READ/WRITE bit-field is used to enable or disable SD Detection and Declaration by the Receive STS-1/STS-3 TOH Processor block. ` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to NOT declare nor clear the SD defect condition per the user-specified SD defect declaration and clearance criteria. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to declare and clear the SD defect condition per the user-specified SD defect declaration and clearance criteria. BIT 4 - De-Scramble Disable This READ/WRITE bit-field is used to either enable or disable de-scrambling by the Receive STS-1/STS-3 TOH Processor block, associated with channel N. ` 0 - De-Scrambling is enabled. ` 1 - De-Scrambling is disabled. BIT 3 - Unused BIT 2 - REI-L Error Type This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will count (or tally) REI-L events, for Performance Monitoring purposes. The user can configure the Receive STS-1/STS-3 TOH Processor block to increment REI-L events on either a per-bit or per-frame basis. If the user configures the Receive STS-1/STS-3 TOH Processor block to increment REI-L events on a per-bit basis, then it will incrememt the Receive STS-1/STS-3 Transport REI-L Error Count register by the value of the lower nibble within the M0/M1 byte of the incoming STS-1/STS-3 data-stream. If the user configures the Receive STS-1/STS-3 TOH Processor block to increment REI-L events on a per-frame basis, then it will increment the Receive STS-1/STS-3 Transport REI-L Error Count register each time it receives an STS1/STS-3 or STS-3 frame, in which the lower nibble of the M0/M1 byte is set to a non-zero value. ` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to count or tally REI-L events on a per-bit basis. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to count or tally REI-L events on a per-frame basis. BIT 1 - B2 Error Type This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will count (or tally) B2 byte errors, for Performance Monitoring purposes. The user can configure the Receive STS-1/STS-3 TOH Processor block to increment B2 byte errors on either a per-bit or a per-frame basis. 72 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B2 byte errors on a per-bit basis, then it will increment the Receive Transport B2 Byte Error Count register by the number of bits (within the B2 byte value) that is in error. If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B2 byte errors on a per-frame basis, then it will increment the Receive Transport B2 Byte Error Count register each time it receives an STS-1/STS-3 frame that contains an erred B2 byte. ` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to count B2 byte errors on a per-bit basis. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to count B2 byte errors on a per-frame basis. BIT 0 - B1 Error Type This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will count (or tally) B1 byte errors, for Performance Monitoring purposes. The user can configure the Receive STS-1/STS-3 TOH Processor block to increment B1 byte errors on either a per-bit or per-frame basis. If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B1 byte errors on a per-bit basis, then it will increment the Receive Transport B1 Byte Error Count register by the number of bits (within the B1 byte value) that is in error. If the user configures the Receive STS-1/STS-3 TOH Processor block to increment B1 byte errors on a per-frame basis, then it will increment the Receive Transport B1 Byte Error Count Register each time it receives an STS-1/STS-3 frame that contains an erred B1 byte. ` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to count B1 byte errors on a per-bit basis. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to count B1 byte errors on a per-frame basis. TABLE 74: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0206) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 Section Trace Section Trace Message (J0) Message (J0) Mismatch Unstable Defect Defect Declared Declared BIT 0 AIS-L Defect Declared R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:3] - Unused BIT 2 - Section Trace Message Mismatch Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Mismatch defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the Section Trace Message Mismatch defect condition, whenever it accepts a Section Trace Message (via the J0 byte, within the incoming STS-1/STS-3 data-stream) that differs from the Expected Section Trace Message. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the Section Trace Message Mismatch Defect Condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Message Mismatch Defect Condition. BIT 1 - Section Trace Message Unstable Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Message Unstable Defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the Section Trace Message Unstable defect condition, whenever the "Section Trace Message Unstable" counter reaches the value 8. The Receive STS-1/STS-3 TOH Processor block will increment the "Section Trace Message Unstable" counter for each time that it receives a Section Trace message that differs from the "Expected Section Trace Message". The Receive STS-1/STS-3 TOH Processor block will clear the "Section Trace Message Unstable" counter to "0" whenever it has received a given Section Trace Message 3 (or 5) consecutive times NOTE: The Receive STS-1/STS-3 TOH Processor block will clear the "Section Trace Message Unstable" defect condition whenever it receives a given Section Trace Message 3 (or 5) consecutive times". ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the Section Trace 73 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Message Unstable defect condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Message Unstable defect condition BIT 0 - AIS-L Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the AIS-L (Line AIS) defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the AISL defect condition within the incoming STS-1/STS-3data stream if bits 6, 7 and 8 (e.g., the Least Significant Bits, within the K2 byte) are set to the value [1, 1, 1] for five consecutive STS-1/STS-3frames. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the AIS-L defect condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the AIS-L defect condition. TABLE 75: RECEIVE STS-1/STS-3 TRANSPORT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0207) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 RDI-L Defect Declared S1 Byte Unstable Defect Declared K1, K2 Byte Unstable Defect Declared SF Defect Declared SD Defect Declared LOFDefect Detected SEFDefect Declared LOSDefect Declared R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - RDI-L Defect Declared Indicator This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is detecting the RDI-L (Line-Remote Defect Indicator) defect condition, within the incoming STS-1/STS-3 signal. The Receive STS1/STS-3 TOH Processor block will declare the RDI-L defect condition whenever bits 6, 7 and 8 (e.g., the three least significant bits) of the K2 byte contains the 1, 1, 0 pattern in 5 consecutive incoming STS-1/STS-3 or STS-3 frames. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the AIS-L defect condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the AIS-L defect condition.. BIT 6 - S1 Byte Unstable Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the S1 Byte Unstable defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the S1 Byte Unstable defect condition whenever the S1 Byte Unstable Counter reaches the value 32. The Receive STS1/STS-3 TOH Processor block will increment the "S1 Byte Unstable Counter" each time that the it receives an STS1/STS-3 or STS-3 frame that contains an S1 byte that differs from the previously received S1 byte. The Receive STS1/STS-3 TOH Processor block will clear the "S1 Byte Unstable Counter" to "0" when the same S1 byte is received for 8 consecutive STS-1/STS-3 frames. NOTE: The Receive STS-1/STS-3 TOH Processor block will clear the "S1 Byte Unstable" defect whenever it receives a given S1 byte, in 8 consecutive STS-1/STS-3 frames. 1. 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the S1 Byte Unstable Defect Condition. 1. 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the S1 Byte Unstable Defect Condition. BIT 5 - K1, K2 Byte Unstable Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the K1, K2 Byte Unstable defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the K1, K2 Byte Unstable defect condition whenever it fails to receive the same set of K1, K2 bytes, in 12 consecutive incoming STS-1/STS-3 frames. The Receive STS-1/STS-3 TOH Processor block will clear the "K1, K2 Byte Unstable" defect whenever it has received a given set of K1, K2 byte values within three consecutive incoming STS-1/STS-3 frames. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the "K1, K2 Byte 74 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Unstable Defect" Condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the "K1, K2 Byte Unstable Defect" Condition. BIT 4 - SF (Signal Failure) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the SF defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition anytime it has determined that the number of B2 byte errors (measured over a user-selected period of time) exceeds a certain user-specified B2 Byte Error threshold. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the SF Defect condition. This bit is set to "0" when the number of B2 byte errors (accumulated over a given interval of time) does not exceed the "SF Defect Declaration" threshold. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the SF Defect condition. This bit is set to "1" when the number of B2 errors (accumulated over a given interval of time) does exceed the "SF Defect Declaration" threshold BIT 3 - SD (Signal Degrade) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the SD defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition anytime it has determined that the number of B2 byte errors (measured over a user-selected period of time) exceeds a certain user-specified B2 Byte Error threshold. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the SD Defect condition. This bit is set to 0 when the number of B2 errors (accumulated over a given interval of time) does not exceed the SD Declaration threshold. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the SD Defect condition. This bit is set to 1 when the number of B2 errors (accumulated over a given interval of time) does exceed the SD Defect Declaration threshold. BIT 2 - LOF (Loss of Frame) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOF defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the LOF defect condition if it has been declaring the SEF condition for 24 consecutive STS-1/STS-3 frame periods. Once the Receive STS-1/STS-3 TOH Processor block has declared the LOF defect condition, then the Receive STS-1/STS-3 TOH Processor block will clear the LOF defect if it has not been declaring the SEF condition for 3ms (or 24 consecutive STS1/STS-3 frame periods). ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the LOF defect condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOF defect condition. BIT 1 - SEF (Severely Errored Frame) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the SEF defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the SEF defect condition if it detects Framing Alignment byte errors in four consecutive STS-1/STS-3 frames. Once the Receive TOH Processor block declares the SEF defect condition, the Receive STS-1/STS-3 TOH Processor block will then clear the SEF defect condition if it detects two consecutive STS-1/STS-3 frames with un-erred framing alignment bytes. If the Receive TOH Processor block declares the SEF defect condition for 24 consecutive STS-1/STS-3 frame periods, then it will declare the LOF defect condition. ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the SEF defect condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the SEF defect condition. BIT 0 - LOS (Loss of Signal) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOS (Loss of Signal) defect condition. The Receive STS-1/STS-3 TOH Processor block will declare the LOS defect condition if it detects LOS_THRESHOLD[15:0] consecutive All Zero bytes in the incoming STS-1/STS-3 data stream. NOTE: The user can set the LOS_THRESHOLD[15:0] value by writing the appropriate data into the Receive STS1/STS-3 Transport - LOS Threshold Value Register (Address Location= 0x022E and 0x022F). 75 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 0 - Indicates that the Receive STS-1/STS-3 TOH Processor block is NOT currently declaring the LOS defect condition. ` 1 - Indicates that the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOS defect condition. TABLE 76: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0209) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Change of AIS-LDefect Condition Interrupt Status Change of RDI-L Defect Condition Interrupt Status R/O R/O R/O R/O R/O R/O RUR RUR 0 0 0 0 0 0 0 0 BIT [7: 2] - Unused BIT 1 - Change of AIS-L (Line AIS) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of AIS-L Defect Condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following occurrences.· Whenever the Receive STS-1/STS-3 TOH Processor block declares the AIS-L defect condition.· Whenever the Receive STS-1/STS-3 TOH Processor block clears the AIS-L defect condition. ` 0 - Indicates that the Change of AIS-L Defect Condition interrupt has not occurred since the last read of this register. ` 1 - Indicates that the Change of AIS-L Defect Condition interrupt has occurred since the last read of this register. NOTE: The user can obtain the current state of the AIS-L defect condition by reading the contents of BIT 0 (AIS-L Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 1 (Address Location= 0x0206). BIT 0 - Change of RDI-L (Line - Remote Defect Indicator) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of RDI-L Defect Condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following occurrences. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the RDI-L defect condition.· • Whenever the Receive STS-1/STS-3 TOH Processor block clears the RDI-L defect condition. ` 0 - Indicates that the Change of RDI-L Defect Condition interrupt has not occurred since the last read of this register. ` 1 - Indicates that the Change of RDI-L Defect Condition interrupt has occurred since the last read of this register.Note: NOTE: The user can obtain the current state of the RDI-L defect condition by reading out the state of BIT7 (RDI-L Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). 76 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 77: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 1 (ADDRESS LOCATION= 0X020A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 New S1 ByteInterrupt Status Change in S1 Byte UnstableDefect ConditionInterrupt Status Change in Section Trace Message Unstable Defect Condition Interrupt Status New Section Trace Message Interrupt Status Change in Section Trace Message MismatchDefect Declared Interrupt Status Unused RUR RUR RUR RUR RUR R/O RUR RUR 0 0 0 0 0 0 0 0 Change in NEW K1K2 K1, K2 Byte Byte Value Unstable Interrupt Status Defect Condtion Interrupt Status BIT 7 - New S1 Byte Value Interrupt Status This RESET-upon-READ bit-field indicates whether or not the New S1 Byte Value Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate the New S1 Byte Value Interrupt, anytime it has accepted a new S1 byte, from the incoming STS-1/STS-3 data-stream. ` 0 - Indicates that the New S1 Byte Value Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the New S1 Byte Value interrupt has occurred since the last read of this register. NOTE: The user can obtain the value for this most recently accepted value of the S1 byte by reading the Receive STS1/STS-3 Transport S1 Byte Value register (Address Location= 0x0227). BIT 6 - Change in S1 Byte Unstable Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in S1 Byte Unstable Defect Condition Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the S1 Byte Unstable defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the S1 Byte Unstable defect condition. ` 0 - Indicates that the Change in S1 Byte Unstable Defect Condition Interrupt has occurred since the last read of this register. ` 1 - Indicates that the Change in S1 Byte Unstable Defect Condition Interrupt has not occurred since the last read of this register. NOTE: The user can obtain the current S1 Byte Unstable Defect condition by reading the contents of BIT6 (S1 Byte Unstable Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). BIT 5 - Change in Section Trace Message Unstable Defect condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in Section Trace Message Unstable defect condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Unstable defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clear the Section Trace Message Unstable defect condition. ` Indicates that the Change in Section Trace Message Unstable defect condition interrupt has not occurred since the last read of this register. ` 1 - Indicates that the Change in Section Trace Message Unstable defect condition interrupt has occurred since the last read of this register. BIT 4 - New Section Trace Message Interrupt Status This RESET-upon-READ bit-field indicates whether or not the New Section Trace Message interrupt has occurred since 77 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it has accepted a new Section Trace Message within the incoming STS-1/STS-3 data-stream. ` 0 - Indicates that the New Section Trace Message Interrupt has not occurred since the last read of this register. ` 1 - Indicates that the New Section Trace Message Interrupt has occurred since the last read of this register. NOTE: The user can read out the contents of the Receive Section Trace Message Buffer, which is located at Address Locations 0x0400 through 0x04FF). BIT 3 - Change in Section Trace Message Mismatch Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in Section Trace Mismatch Defect Condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events.· Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Mismatch defect condition· Whenever the Receive STS-1/STS-3 TOH Processor block clears the Section Trace Mismatch defect condition. ` 0 - Indicates that the Change in Section Trace Message Mismatch Defect Condition interrupt has not occurred since the last read of this register. ` 1 - Indicates that the Change in Section Trace Message Mismatch Defect Condition interrupt has occurred since the last read of this register. NOTE: The user can determine whether the Section Trace Message Mismatch condition is currently cleared or declared by reading the state of BIT 2 (Section Trace Message Mismatch Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 1 (Address Location= 0x0206). BIT 2 - Unused BIT 1 - Change in K1, K2 Byte Unstable Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in K1, K2 Byte Unstable Defect Condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the K1, K2 Byte Unstable Defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the K1, K2 Byte Unstable Defect condition. ` 0 - Indicates that the Change of K1, K2 Byte Unstable Defect Condition interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of K1, K2 Byte Unstable Defect Condition interrupt has occurred since the last read of this register. NOTE: The user can determine whether the K1, K2 Byte Unstable Defect Condition is currently being declared or cleared by reading out the contents of BIT 5 (K1, K2 Byte Unstable Defect Declared), within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). BIT 0 - New K1, K2 Byte Value Interrupt Status This RESET-upon-READ bit-field indicates whether or not the New K1, K2 Byte Value Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt whenever its has accepted a new set of K1, K2 byte values from the incoming STS-1/STS-3 data-stream ` 0 - Indicates that the New K1, K2 Byte Value Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the New K1, K2 Byte Value Interrupt has occurred since the last read of this register. NOTE: The user can obtain the contents of the new K1 byte by reading out the contents of the Receive STS-1/STS-3 Transport K1 Byte Value Register (Address Location= 0xN11F). Further, the user can also obtain the contents of the new K2 byte by reading out the contents of the Receive STS-1/STS-3 Transport K2 Byte Value Register (Address Location= 0x0223). 78 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 78: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION= 0X020B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of SF Defect ConditionInterrupt Status Change of SD Defect Condition Interrupt Status Detection of REI-L Event Error Interrupt Status Detection of B2 Byte Error Interrupt Status Detection of B1 Byte Error Interrupt Status RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 Change of Change of Change of LOF Defect SEF Defect LOS Defect Condition Interrupt StaCondition tus Interrupt StaInterrupt Status tus BIT 7 - Change of Signal Failure (SF) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of SF Defect Condition Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the SF Defect Condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the SF Defect Condition. ` 0 - Indicates that the Change of SF Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of SF Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine whether or not the SF defect condition is currently being declared by reading out the state of BIT 4( SF Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). BIT 6 - Change of Signal Degrade (SD) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of SD Defect Condition Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenver the Receive STS-1/STS-3 TOH Processor block declares the SD Defect Condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the SD Defect Condition. ` 0 - Indicates that the Change of SD Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of SD Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine whether or not the SD Defect condition is currently being declareds by reading out the state of BIT 3 (SD Defect Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). BIT 5 - Detection of REI-L (Line - Remote Error Indicator) Event Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of REI-L Event Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it detects an REI-L event within the incoming STS-1/STS-3 data-stream. ` 0 - Indicates that the Detection of REI-L Event Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of REI-L Event Interrupt has occurred since the last read of this register. BIT 4 - Detection of B2 Byte Error Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of B2 Byte Error Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it detects a B2 byte error within the incoming STS-1/STS-3 data-stream. ` 0 - Indicates that the Detection of B2 Byte Error Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of B2 Byte Error Interrupt has occurred since the last read of this register. BIT 3 = Detection of B1 Byte Error Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of B1 Byte Error Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it 79 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 detects a B1 byte error within the incoming STS-1/STS-3 data-stream. ` 0 - Indicates that the Detection of B1 Byte Error Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of B1 Byte Error Interrupt has occurred since the last read of this register BIT 2 - Change of Loss of Frame (LOF) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of LOF Defect Condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the LOF Defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the LOF Defect condition. ` 0 - Indicates that the Change of LOF Defect Condition interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of LOF Defect Condition interrupt has occurred since the last read of this register. NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOF defect condition by reading out the state of BIT 2 (LOF Defect Declared) within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). BIT 1 - Change of SEF Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of SEF Defect Condition Interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the SEF defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the SEF defect condition. ` 0 - Indicates that the Change of SEF Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of SEF Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the SEF defect condition by reading out the state of BIT 1 (SEF Defect Declared) within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). BIT 0 - Change of Loss of Signal (LOS) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of LOS Defect Condition interrupt has occurred since the last read of this register. The Receive STS-1/STS-3 TOH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the LOS defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the LOS defect condition. ` 0 - Indicates that the Change of LOS Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of LOS Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the LOS defect condition by reading out the contents of BIT 0 (LOS Defect Declared) within the Receive STS1/STS-3 Transport Status Register - Byte 0 (Address Location= 0x0207). TABLE 79: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 2 (ADDRESS LOCATION= 0X020D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Change of AIS-LDefect Condition Interrupt Enable Change of RDI-LDefect Condition Interrupt Enable R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:2] - Unused 80 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT 1- Change of AIS-L (Line AIS) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of AIS-L Defect Condition interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions. • When the Receive STS-1/STS-3 TOH Processor block declares the AIS-L defect condition.· • When the Receive STS-1/STS-3 TOH Processor block clears the AIS-L defect condition. ` 0 - Disables the Change of AIS-L Defect Condition Interrupt. ` 1 - Enables the Change of AIS-L Defect Condition Interrupt. BIT 0 - Change of RDI-L (Line Remote Defect Indicator) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of RDI-L Defect Condition interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions.· When the Receive STS-1/STS-3 TOH Processor block declares the RDI-L defect condition.· When the Receive STS1/STS-3 TOH Processor block clears the RDI-L defect condition. ` 0 - Disables the Change of RDI-L Defect Condition Interrupt. ` 1 - Enables the Change of RDI-L Defect Condition Interrupt. TABLE 80: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT ENABLE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X020E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 New S1 Byte Interrupt Enable Change in S1 Byte Unstable Defect ConditionInterrupt Enable Change in Section Trace Message Unstable Defect Condition Interrupt Enable New Section Trace Message Interrupt Enable Change in Section Trace Message Mismatch Defect Condition Interrupt Enable Unused Change in K1, K2 Byte Unstable Defect ConditionInterrupt Enable New K1K2 Byte Value Interrupt Enable R/W R/W R/W R/W R/W R/O R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - New S1 Byte Value Interrupt Enable This READ/WRITE bit-field is used to enable or disable the New S1 Byte Value Interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it receives and accepts a new S1 byte value. The Receive STS-1/STS-3 TOH Processor block will accept a new S1 byte after it has received it for 8 consecutive STS-1/STS-3 frames. ` 0 - Disables the New S1 Byte Value Interrupt. ` 1 - Enables the New S1 Byte Value Interrupt. BIT 6 - Change in S1 Byte Unstable Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change in S1 Byte Unstable Defect Condition Interrupt.. If the user enables this bit-field, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt in response to either of the following conditions • When the Receive STS-1/STS-3 TOH Processor block declares the S1 Byte Unstable defect condition • When the Receive STS-1/STS-3 TOH Processor block clears the S1 Byte Unstable defect condition. ` 0 - Disables the Change in S1 Byte Unstable Defect Condition Interrupt. ` 1 - Enables the Change in S1 Byte Unstable Defect Condition Interrupt. BIT 5 - Change in Section Trace Message Unstable defect condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change in Section Trace Message Unstable Defect Condition Interrupt. 81 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt in response to either of the following conditions. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Unstable defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the Section Trace Message Unstable defect condition. ` 0 - Disable the Change of Section Trace Message Unstable defect condition Interrupt. ` 1 - Enables the Change of Section Trace Message Unstable defect condition Interrupt. BIT 4 - New Section Trace Message Interrupt Enable This READ/WRITE bit-field is used to enable or disable the New Section Trace Message interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it receives and accepts a new Section Trace Message within the incoming STS-1/STS-3 data-stream. The Receive STS1/STS-3 TOH Processor block will accept a new Section Trace Message after it has received it 3 (or 5) consecutive times. ` 0 - Disables the New Section Trace Message Interrupt. ` 1 - Enables the New Section Trace Message Interrupt. BIT 2 - Unused BIT 3 - Change in Section Trace Mismatch Defect Condition interrupt enable: This READ/WRITE bit-field is used to either enable or disable the Change in Section Trace Mismatch defect condition interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the Section Trace Message Mismatch Defect condition. • whenever the Receive STS-1/STS-3 TOH Processor block clears the Section Trace Message Mismatch defect condition. NOTE: The user can determine whether or not the Receive STS-1/STS-3 TOH Processor block is currently declaring the Section Trace Message Mismatch defect condition by reading the state of BIT 2 (Section Trace Message Mismatch Defect Condition Declared) within the Receive STS-1/STS-3 Transport Status Register - Byte 1 (Address Location= 0x0206). BIT 1 - Change of K1, K2 Byte Unstable Defect Condition - Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of K1, K2 Byte Unstable defect condition interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an Interrupt in response to either of the following events.a.Whenever the Receive STS-1/STS-3 TOH Processor block declares the K1, K2 Byte Unstable defect condition. b.Whenever the Receive STS-1/STS-3 TOH Processor block clears the K1, K2 Byte Unstable defect condition. ` 0 - Disables the Change of K1, K2 Byte Unstable Defect Condition Interrupt. ` 1 - Enables the Change of K1, K2 Byte Unstable Defect Condition Interrupt. BIT 0 - New K1, K2 Byte Value Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the New K1, K2 Byte Value Interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate this interrupt anytime it receives and accepts a new K1, K2 byte value. The Receive STS-1/STS-3 TOH Processor block will accept a new K1, K2 byte value, after it has received it within 3 (or 5) consecutive STS-1/STS-3 frames. ` 0 - Disables the New K1, K2 Byte Value Interrupt. ` 1 - Enables the New K1, K2 Byte Value Interrupt. 82 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 81: RECEIVE STS-1/STS-3 TRANSPORT INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS LOCATION= 0X020F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of SF DefectCondition Interrupt Enable Change of SD Defect Condition Interrupt Enable Detection of REI-L Event Interrupt Enable Detection of B2 Byte Error Interrupt Enable Detection of B1 Byte Error Interrupt Enable Change of LOF Defect Condition Interrupt Enable Change of SEF Defect Condition Interrupt Enable Change of LOS Defect Condition Interrupt Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Change of Signal Failure (SF) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of Signal Failure (SF) Defect Condition Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to any of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor block declares the SF defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the SF defect condition. ` 0 - Disables the Change of SF Defect Condition Interrupt. ` 1 - Enables the Change of SF Defect Condition Interrupt. BIT 6 - Change of Signal Degrade (SD) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of Signal Degrade (SD) Defect Condition Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following events. • Whenever the Receive STS-1/STS-3 TOH Processor blolck declares the SD defect condition. • Whenever the Receive STS-1/STS-3 TOH Processor block clears the SD defect condition. ` 0 - Disables the Change of SD Defect Condition Interrupt. ` 1 - Enables the Change of SD Defect Condition Interrupt. BIT 5 - Detection of REI-L (Line - Remote Error Indicator) Event Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of REI-L Event interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt anytime the Receive STS-1/STS-3 TOH Processor block detects an REI-L condition within the incoming STS-1/STS-3 data-stream. ` 0 - Disables the Detection of REI-L Event Interrupt. ` 1 - Enables the Detection of REI-L Event Interrupt. BIT 4 - Detection of B2 Byte Error Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of B2 Byte Error Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt anytime the Receive STS-1/STS-3 TOH Processor block detects a B2 byte error within the incoming STS-1/STS-3 data-stream. ` 0 - Disables the Detection of B2 Byte Error Interrupt. ` 1 - Enables the Detection of B2 Byte Error Interrupt. BIT 3 - Detection of B1 Byte Error Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Detection of B1 Byte Error Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt anytime the Receive STS-1/STS-3 TOH Processor block detects a B1 byte error within the incoming STS-1/STS-3 data-stream. ` 0 - Disables the Detection of B1 Byte Error Interrupt. ` 1 - Enables the Detection of B1 Byte Error Interrupt. BIT 2 - Change of Loss of Frame (LOF) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of LOF Defect Condition interrupt. If this 83 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions • When the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition • When the Receive STS-1/STS-3 TOH Processor block clears the LOF defect condition. ` 0 - Disables the Change of LOF Defect Condition Interrupt. ` 1 - Enables the Change of LOF Defect Condition Interrupt. BIT 1 - Change of SEF Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of SEF Defect Condition Interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions. • When the Receive STS-1/STS-3 TOH Processor block declares the SEF defect condition. • When the Receive STS-1/STS-3 TOH Processor block clears the SEF defect condition. ` 0 - Disables the Change of SEF Defect Condition Interrupt. ` 1 - Enables the Change of SEF Defect Condition Interrupt. BIT 0 - Change of Loss of Signal (LOS) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of LOF Defect Condition interrupt. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions. • When the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition. • When the Receive STS-1/STS-3 TOH Processor block clears the LOF defect condition. ` 0 - Disables the Change of LOF Defect Condition Interrupt. ` 1 - Enables the Change of LOF Defect Condition Interrupt. TABLE 82: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0210) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B1_Byte_Error_Count[31:24] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B1 Byte Error Count - MSB This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes 2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B1 byte errorwithin the incoming STS-1/STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor Block is configured to count B1 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming STS-1/STS-3 frame) that are in error 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B1 byte. TABLE 83: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0211) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B1_Byte_Error_Count[23:16] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 84 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT [7:0] - B1 Byte Error Count (Bits 23 through 16) This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes 3, 1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B1 byte error. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming STS-1/STS-3 frame) that are in error. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B1 byte. TABLE 84: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0212) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B1_Byte_Error_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B1 Byte Error Count - (Bits 15 through 8) This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes 3, 2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B1 byte error. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming STS-1/STS-3 frame) that are in error 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B1 byte. TABLE 85: RECEIVE STS-1/STS-3 TRANSPORT - B1 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0213) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B1_Byte_Error_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B1 Byte Error Count - LSB This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B1 Byte Error Count Register - Bytes 3 through 1, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B1 byte error. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor Block is configured to count B1 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B1 byte (of each incoming STS-1/STS-3 frame) that are in error. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B1 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B1 byte. 85 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 86: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0214) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B2_Byte_Error_Count[31:24] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B2 Byte Error Count - MSB This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - B2 Byte Error Count Register - Bytes 2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B2 byte (or BIP-24) error within the incoming STS-1/STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming STS-1/STS-3 frame) that are in error. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B2 byte or errered BIP-24. TABLE 87: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0215) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B2_Byte_Error_Count[23:16] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B2 Byte Error Count (Bits 23 through 16) This RESET-upon-READ register, along with Receive Transport - B2 Byte Error Count Register - Bytes 3, 1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B2 byte or BIP-24 error within the incoming STS-1/STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming STS-1/STS-3 frame) that are in error. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B2 byte or erred BIP-24. TABLE 88: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0216) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B2_Byte_Error_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B2 Byte Error Count - (Bits 15 through 8) 86 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This RESET-upon-READ register, along with Receive Transport - B2 Byte Error Count Register - Bytes 3, 2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B2 byte or BIP-24 error within the incoming STS-1/STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processror block is configured to count B2 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming STS-1/STS-3 frame) that are in error. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B2 byte or erred BIP-24. TABLE 89: RECEIVE STS-1/STS-3 TRANSPORT - B2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0217) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B2_Byte_Error_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B2 Byte Error Count - LSB This RESET-upon-READ register, along with Receive Transport - B2 Byte Error Count Register - Bytes 3 through 1, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a B2 byte or BIP-24 error within the incoming STS-1/STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B2 byte (of each incoming STS-1/STS-3 frame) that are in error. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count B2 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 frame that contains an erred B2 byte or erred BIP-24. TABLE 90: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION = 0X0218) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-L_Event_Count[31:24] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-L Event Count - MSB This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a Line - Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte within each incoming STS-1/STS-3 frame. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that contains a non-zero REI-L value. 87 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 91: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0219) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-L_Event_Count[23:16] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-L Event Count (Bits 23 through 16) This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 3, 1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a Line - Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte (or the contents within the M1 byte) within each incoming STS-1 (or STS-3) frame. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that contains a non-zero REI-L value. TABLE 92: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X021A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-L_Event_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-L Event Count - (Bits 15 through 8) This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 3, 2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a Line -Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte (or the contents within the M1 byte) within each incoming STS-1 (or STS-3) frame. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that contains a non-zero REI-L value. TABLE 93: RECEIVE STS-1/STS-3 TRANSPORT - REI-L EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X021B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-L_Event_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-L Event Count - LSB This RESET-upon-READ register, along with Receive STS-1/STS-3 Transport - REI-L Event Count Register - Bytes 3 88 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS through 1, function as a 32 bit counter, which is incremented anytime the Receive STS-1/STS-3 TOH Processor block detects a Line - Remote Error Indicator event within the incoming STS-1 or STS-3 data-stream. NOTES: 1. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-L field of the M0 byte (or the contents within the M1 byte) within each incoming STS-1 (or STS-3) frame. 2. If the Receive STS-1/STS-3 TOH Processor block is configured to count REI-L events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1 or STS-3 frame that contains a non-zero REI-L value. TABLE 94: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X021F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Filtered_K1_Byte_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0]Filtered/Accepted K1 Byte Value These READ-ONLY bit-fields contain the value of the most recently filtered K1 byte value that the Receive STS-1/STS3 TOH Processor block has received. These bit-fields are valid if the K1/K2 pair (to which it belongs) has been received for 3 consecutive STS-1 or STS-3 frames. This register should be polled by Software in order to determine various APS codes. TABLE 95: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED K2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0223) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Filtered_K2_Byte_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0]Filtered/Accepted K2 Byte Value These READ-ONLY bit-fields contain the value of the most recently filtered K2 Byte value that the Receive STS-1/STS3 TOH Processor block has received. These bit-fields are valid if the K1/K2 pair (to which it belongs) has been received for 3 consecutive STS-1 or STS-3 frames. This register should be polled by Software in order to determine various APS codes. TABLE 96: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVED S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0227) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Filtered_S1_Byte_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Filtered/Accepted S1 Byte Value These READ-ONLY bit-fields contain the value of the most recently filtered S1 byte value that the Receive STS-1/STS3 TOH Processor block has received. These bit-fields are valid if it has been received for 8 consecutive STS-1 or STS3 frames. 89 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 97: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE IN-SYNC THRESHOLD REGISTER (ADDRESS = 0X022B) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 FRPATOUT[1:0] BIT 1 FRPATIN[1:0] BIT 0 Unused R/O R/O R/O R/W R/W R/W R/W R/O 0 0 0 0 0 0 0 0 BIT [7:5] - Unused BIT [4:3] - FRPATOUT[1:0] BIT [2:1] - FRPATIN[1:0] BIT 0 - Unused TABLE 98: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - MSB (ADDRESS LOCATION= 0X022E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LOS_THRESHOLD[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - LOS Threshold Value - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - LOS Threshold Value - LSB register is used specify the number of consecutive (All Zero) bytes that the Receive STS-1/STS-3 TOH Processor block must detect (within the incoming STS-1/STS-3 data-stream) before it can declare the LOS defect condition. NOTE: This register contains the MSB (Most Significant Byte) of this 16-bit expression. TABLE 99: RECEIVE STS-1/STS-3 TRANSPORT - LOS THRESHOLD VALUE - LSB (ADDRESS LOCATION= 0X022F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LOS_THRESHOLD[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - LOS Threshold Value - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - LOS Threshold Value - MSB register is used to specify the number of consecutive (All Zero) bytes that the Receive STS-1/STS-3 TOH Processor block must detect (within the incoming STS-1/STS-3 data-stream) before it can declare the LOS defect condition. NOTE: This register contains the LSB (Least Significant Byte) of this 16-bit expression. TABLE 100: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X0231) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_SET_MONITOR_WINDOW[23:16] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_SET_MONITOR_INTERVAL - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Monitor Interval - Byte 90 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS 1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) Defect Declaration. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1/STS-3 signal in order to determine if it should declare the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Declaration monitoring period. If, during this SF Defect Declaration Monitoring Period, the Receive STS-1/STS-3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive Transport SF SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition. NOTES: 1. The value that the user writes into these three (3) SF Set Monitor Window registers, specifies the duration of the SF Defect Declaration Monitoring Period, in terms of ms. 2. This particular register byte contains the MSB (most significant byte) value of the three registers that specify the SF Defect Declaration Monitoring Period. TABLE 101: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X0232) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_SET_MONITOR_WINDOW[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_SET_MONITOR_INTERVAL (Bits 15 through 8) These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Monitor Interval - Byte 2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) Defect Declaration. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1/STS-3 signal in order to determine if it should declare the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Declaration Monitoring Period. If, during this SF Defect Declaration Monitoring Period the Receive STS-1/STS-3 TOH Processor block accumulate more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3 Transport SF SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition. NOTE: The value that the user writes into these three (3) SF Set Monitor Window registers, specifies the duration of the SF Defect Declaration Monitoring Period, in terms of ms. TABLE 102: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X0233) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_SET_MONITOR_WINDOW[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_SET_MONITOR_INTERVAL - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Monitor Interval - Byte 2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) Defect Declaration. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1/STS-3 signal in order to determine if it should declare the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the user-specified SF Defect Declaration Monitoring Period. If, during this SF Defect Declaration Monitoring Period, the Receive STS-1/STS-3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3 Transport SF SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition. 91 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 NOTES: 1. The value that the user writes into these three (3) SF Set Monitor Window registers, specifies the duration of the SF Defect Declaration Monitoring Period, in terms of ms. 2. This particular register byte contains the LSB (least significant byte) value of the three registers that specify the SF Defect Declaration Monitoring period. TABLE 103: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0236) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_SET_THRESHOLD[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_SET_THRESHOLD - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Threshold - Byte 0 registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to declare the SF (Signal Failure) Defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SF Defect Declaration Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors exceeds that value, which is programmed into this and the Receive STS-1/STS3 Transport SF SET Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition. NOTE: This particular register byte contains the MSB (most significant byte) value of this 16-bit expression. TABLE 104: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF SET THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X0237) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_SET_THRESHOLD[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_SET_THRESHOLD - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF SET Threshold - Byte 1 registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to declare the SF (Signal Failure) Defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SF Defect Monitoring Period. If the number of accumulated B2 byt (or BIP-24)e errors exceeds that which has been programmed into this and the Receive STS-1/STS-3 Transport SF SET Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will declare the SF defect condition. TABLE 105: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X023A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_CLEAR_THRESHOLD[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 92 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT [7:0] - SF_CLEAR_THRESHOLD - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF CLEAR Threshold - Byte 0 registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to clear the SF (Signal Failure) defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SF Defect Clearance Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport SF CLEAR Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block clear the SF defect condition. TABLE 106: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X023B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_CLEAR_THRESHOLD[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_CLEAR_THRESHOLD - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF CLEAR Threshold - Byte 1 registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to clear the SF (Signal Failure) defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SF Defect Clearance Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport SF CLEAR Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will clear the SF defect condition. TABLE 107: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X023D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_SET_MONITOR_WINDOW[23:16] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - SD_SET_MONITOR_INTERVAL - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Monitor Interval - Byte 1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect declaration. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should declare the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the user-specified SD Defect Declaration monitoring period. If, during this SD Defect Declaration Monitoring period, the Receive STS-1/STS3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3 Transport SD SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition. NOTES: 1. The value that the user writes into these three (3) SD Set Monitor Window registers, specifies the duration of the SD Defect Declaration Monitoring Period, in terms of ms. 2. This particular register byte contains the MSB (Most significant byte) value of the three registers that specify the SD Defect Declaration Monitoring Period. 93 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 108: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X023E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_SET_MONITOR_WINDOW[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - SD_SET_MONITOR_INTERVAL - Bits 15 through 8 These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Monitor Interval - Byte 2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect declaration. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine it it should declare the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Declaration Monitoring Period. If, during this SD Defect Declaration Monitoring Period the Receive STS-1/STS-3 TOH Processor block accumulates more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3 Transport SD SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition. NOTE: The value that the user writes into these three (3) SD Set Monitor Window registers, specifies the duration of the SD Defect Declaration Monitoring Period, in terms of ms. TABLE 109: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X023F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_SET_MONITOR_WINDOW[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - SD_SET_MONITOR_INTERVAL - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Monitor Interval - Byte 2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect declaration. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should declare the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspeciifed SD Defect Declaration Monitoring Period. If, during this SD Defect Declaration Monitoring Period, the Receive STS-1/STS-3 TOH Processor block accmulattes more B2 byte (or BIP-24) errors than that specified within the Receive STS-1/STS-3 Transport SD SET Threshold register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition. NOTES: 1. The value that the user writes into these three (3) SD Set Monitor Window registers, specifies the duration of the SD Defect Declaration Monitoring Period, in terms of ms. 2. This particular register byte contains the LSB (least significant byte) value of the three registers that specify the SD Defect Declaration Monitoring period. 94 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 110: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0242) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_SET_THRESHOLD[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_SET_THRESHOLD - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Threshold - Byte 0 registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to declare the SD (Signal Degrade) defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SD Defect Declaration Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors exceeds that value, which is programmed into this and the Receive STS-1/STS3 Transport SD SET Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition. TABLE 111: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD SET THRESHOLD - BYTE 0 (ADDRESS LOCATION= 0X0243) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_SET_THRESHOLD[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_SET_THRESHOLD - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD SET Threshold - Byte 1 registers are used to specify the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to declare an SD (Signal Degrade) defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for declaring the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SD Defect Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors exceeds that which has been programmed into this and the Receive STS-1/STS-3 Transport SD SET Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will declare the SD defect condition. TABLE 112: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0246) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_CLEAR_THRESHOLD[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_CLEAR_THRESHOLD - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD CLEAR Threshold - Byte 0 registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to clear the SD (Signal Degrade) defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SD Defect Clearance Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport 95 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 SD CLEAR Threshold - Byte 0 register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect condition. TABLE 113: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR THRESHOLD - BYTE 1 (ADDRESS LOCATION= 0X0247) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_CLEAR_THRESHOLD[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_CLEAR_THRESHOLD - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD CLEAR Threshold - Byte 1 registers are used to specify the upper limit for the number of B2 byte (or BIP-24) errors that will cause the Receive STS-1/STS-3 TOH Processor block to clear the SD (Signal Degrade) defect condition. When the Receive STS-1/STS-3 TOH Processor block is checking for clearing the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the SD Defect Clearance Monitoring Period. If the number of accumulated B2 byte (or BIP-24) errors is less than that programmed into this and the Receive STS-1/STS-3 Transport SD CLEAR Threshold - Byte 1 register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect condition. TABLE 114: RECEIVE STS-1/STS-3 TRANSPORT - FORCE SEF DEFECT CONDITION REGISTER (ADDRESS LOCATION= 0X024B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Unused BIT 0 SEF FORCE R/O R/O R/O R/O R/O R/O R/O R/W 0 0 0 0 0 0 0 0 BIT [7:1] - Unused BIT 0 - SEF Defect Condition FORCE This READ/WRITE bit-field is used to force the Receive STS-1/STS-3 TOH Processor block (within the corresponding Channel) to declare the SEF defect condition. The Receive STS-1/STS-3 TOH Processor block will then attempt to reacquire framing. Writing a 1 into this bit-field configures the Receive STS-1/STS-3 TOH Processor block to declare the SEF defect. The Receive STS-1/STS-3 TOH Processor block will automatically set this bit-field to 0 once it has reacquired framing (e.g., has detected two consecutive STS-1 or STS-3 frames with the correct A1 and A2 bytes). TABLE 115: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SECTION TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS LOCATION= 0X024F) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 Receive Section Trace Message Buffer Read Select Receive Section Trace Message Accept Threshold Section Trace Message Alignment Type BIT 1 BIT 0 Receive Section Trace Message Length[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:5] - Unused 96 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT 4Receive Section Trace Message Buffer Read Selection This READ/WRITE bit-field is used to specify which of the following Receive Section Trace Message buffer segments to read. • The Actual Receive Section Trace Message Buffer which contains the contents of the most recently received (and accepted) Section Trace Message via the incoming STS-1 or STS-3 data-stream. • The Expected Receive Section Trace Message Buffer which contains the contents of the Section Trace Message that the user expects to receive. The contents of this particular buffer are usually specified by the user. ` 0 - Executing a READ to the Receive Section Trace Message Buffer address space, will return contents within the Actual Receive Section Trace Message buffer. ` 1 - Executing a READ to the Receive Section Trace Message Buffer address space will return contents within the Expected Receive Section Trace Message Buffer. NOTE: In the case of the Receive STS-3 TOH Processor block, the Receive Section Trace Message Buffer is located at Address Location 0x0400 through 0x043F. BIT 3 - Receive Section Trace Message Accept Threshold This READ/WRITE bit-field is used to select the number of consecutive times that the Receive STS-1/STS-3 TOH Processor block must receive a given Section Trace Message, before it is accepted, as described below. Once a given Section Trace Message has been accepted then it can be read out of the Actual Receive Section Trace Message Buffer. ` 0 - The Receive STS-1/STS-3 TOH Processor block accepts the Section Trace Message after it has received it the third time in succession. ` 1 - The Receive STS-1/STS-3 TOH Processor block accepts the Section Trace Message after it has received in the fifth time in succession. BIT 2 - Section Trace Message Alignment Type This READ/WRITE bit-field is used to specify how the Receive STS-1/STS-3 TOH Processor block will locate the boundary of the Section Trace Message within the incoming STS-1 or STS-3 data-stream, as indicated below. ` 0 - Message boundary is indicated by Line Feed. ` 1 - Message boundary is indicated by the presence of a 1 in the MSB of the first byte (within the Section Trace Message). BIT [1:0] - Receive Section Trace Message Length[1:0] These READ/WRITE bit-fields are used to specify the length of the Section Trace Message that the Receive STS1/STS-3 TOH Processor block will receive. The relationship between the content of these bit-fields and the corresponding Receive Section Trace Message Length is presented below Trace Message Length RECEIVE SECTION TRACE MESSAGE LENGTH[1:0] RESULTING RECEIVE SECTION TRACE MESSAGE LENGTH (IN TERMS OF BYTES) 00 1 Byte 01 16 Bytes 10/11 64 Bytes TABLE 116: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 1 (ADDRESS LOCATION= 0X0252) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_BURST_TOLERANCE[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 97 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT [7:0] - SD_BURST_TOLERANCE - MSB These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SD BURST Tolerance - Byte 0 registers are used to specify the maximum number of B2 byte (or BIP-24) errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame period), when determining whether or not to declare the SD (Signal Degrade) defect condition. NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SD defect condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SD defect condition. TABLE 117: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD BURST ERROR TOLERANCE - BYTE 0 (ADDRESS LOCATION= 0X0253) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_BURST_TOLERANCE[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_BURST_TOLERANCE - LSB These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SD BURST Tolerance - Byte 1 registers are used to specify the maximum number of B2 byte (or BIP-24) errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame period), when determining whether or not to declare the SD (Signal Degrade) defect condition. NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SD defect condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SD defect condition. TABLE 118: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 1 (ADDRESS LOCATION= 0X0256) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_BURST_TOLERANCE[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_BURST_TOLERANCE - MSB These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SF BURST Tolerance - Byte 0 registers are used to specify the maximum number of B2 byte (or BIP-24) errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame period), when determining whether or not to declare the SF (Signal Failure) defect condition. NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SF defect condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SF defect condition. 98 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 119: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF BURST ERROR TOLERANCE - BYTE 0 (ADDRESS LOCATION= 0X0257) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_BURST_TOLERANCE[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_BURST_TOLERANCE - LSB These READ/WRITE bits, along with the contents of the Receive STS-1/STS-3 Transport - SF BURST Tolerance - Byte 1 registers are used to specify the maximum number of B2 byte (or BIP-24)errors that the corresponding Receive STS1/STS-3 TOH Processor block can accumulate during a single Sub-Interval period (e.g., an STS-1 or STS-3 frame period), when determining whether or not to declare the SF (Signal Failure) defect condition. NOTE: The purpose of this feature is to are used to provide some level of B2 error burst filtering, when the Receive STS-1/STS-3 TOH Processor block is accumulating B2 byte (or BIP-24) errors in order to declare the SF defect condition. The user can implement this feature in order to configure the Receive STS-1/STS-3 TOH Processor block to detect B2 bit errors in multiple Sub-Interval periods before it will declare the SF defect condition. TABLE 120: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X0259) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_CLEAR_MONITOR_WINDOW[23:16] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_CLEAR_MONITOR_INTERVAL - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD Clear Monitor Interval - Byte 1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect clearance. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should clear the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Clearance Monitoring period. If, during this SD Defect Clearance Monitoring period, the Receive STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive STS-1/STS-3 Transport SD Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect condition. NOTES: 1. The value that the user writes into these three (3) SD Clear Monitor Window Registers, specifies the duration of the SD Defect Clearance Monitoring Period, in terms of ms. 2. This particular register byte contains the MSB (Most significant byte) value of the three registers that specifiy the SD Defect Clearance Monitoring period. TABLE 121: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X025A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SD_CLEAR_MONITOR_WINDOW[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SD_CLEAR_MONITOR_INTERVAL - Bits 15 through 8 99 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD Clear Monitor Interval - Byte 2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect clearance. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should clear the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Clearance Monitoring period. If, during this SD Defecf Clearance Monitoring Period, the Receive STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive STS-1/STS-3 Transport SD Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect condition. NOTE: The value that the user writes into these three (3) SD Clear Monitor Window Registers, specifies the duration of the SD Defect Clearance Monitoring Period, in terms of ms. TABLE 122: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SD CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X025B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 SD_CLEAR_ MONITOR_ WINDOW[7:0] BIT [7:0] - SD_CLEAR_MONITOR_INTERVAL - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SD Clear Monitor Interval - Byte 2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SD (Signal Degrade) defect clearance .When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should clear the SD defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SD Defect Clearance Monitoring period. If, during this SD Defect Clearance Monitoring period, the Receive STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive STS-1/STS-3 Transport SD Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the SD defect condition NOTES: 1. The value that the user writes into these three (3) SD Clear Monitor Window Registers, specifies the duration of the SD Defect Clearance Monitoring Period, in terms of ms. 2. This particular register byte contains the LSB (least significant byte) value of the three registers that specify the SD Defect Clearance Monitoring period. TABLE 123: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 2 (ADDRESS LOCATION= 0X025D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_CLEAR_MONITOR_WINDOW[23:16] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_CLEAR_MONITOR_INTERVAL - MSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF Clear Monitor Interval - Byte 1 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) defect clearance. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should clear the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the user- 100 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS specified SF Defect Clearance Monitoring period. If, during this SF Defect Clearance Monitoring period, the Receive STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive STS-1/STS-3 Transport SF Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor blolck will clear the SF defect condition. NOTES: 1. The value that the user writes into these three (3) SF Clear Monitor Window Registers, specifies the duration of the SF Defect Clearance Monitoring Period, in terms of ms. 2. This particular register byte contains the MSB (Most significant byte) value of the three registers that specify the SF Defect Clearance Monitoring period. TABLE 124: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 1 (ADDRESS LOCATION= 0X025E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_CLEAR_MONITOR_WINDOW[15:8] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_CLEAR_MONITOR_INTERVAL - Bits 15 through 8 These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF Clear Monitor Interval - Byte 2 and Byte 0 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) defect clearance. When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should clear the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Clearance Monitoring period. If, during this SF Defect Clearance Monitoring period, the Receive STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive STS-1/STS-3 Transport SF Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the SF defect condition. NOTE: The value that the user writes into these three (3) SF Clear Monitor Window Registers, specifies the duration of the SF Defect Clearance Monitoring Period, in terms of ms. TABLE 125: RECEIVE STS-1/STS-3 TRANSPORT - RECEIVE SF CLEAR MONITOR INTERVAL - BYTE 0 (ADDRESS LOCATION= 0X025F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SF_CLEAR_MONITOR_WINDOW[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - SF_CLEAR_MONITOR_INTERVAL - LSB These READ/WRITE bits, along the contents of the Receive STS-1/STS-3 Transport - SF Clear Monitor Interval - Byte 2 and Byte 1 registers are used to specify the length of the monitoring period (in terms of ms) for SF (Signal Failure) defect clearance When the Receive STS-1/STS-3 TOH Processor block is checking the incoming STS-1 or STS-3 signal in order to determine if it should clear the SF defect condition, it will accumulate B2 byte (or BIP-24) errors throughout the userspecified SF Defect Clearance Monitoring period. If, during this SF Defect Clearance Monitoring period, the Receive STS-1/STS-3 TOH Processor block accumulates less B2 byte (or BIP-24) errors than that programmed into the Receive STS-1/STS-3 Transport SF Clear Threshold register, then the Receive STS-1/STS-3 TOH Processor block will clear the SF defect condition. NOTES: 1. The value that the user writes into these three (3) SF Clear Monitor Window Registers, specifies the duration of the SF Defect Clearance Monitoring Period, in terms of ms. 101 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 2. This particular register byte contains the LSB (Least Significant byte) value of the three registers that specify the SF Defect Clearance Monitoring period. TABLE 126: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X0263) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit AIS-P (Downstream) upon Section Trace Message Unstable Transmit AIS-P (Downstream) Upon Section Trace Message Mismatch Transmit AIS-P (Downstream) upon SF Transmit AIS-P (Downstream) upon SD Unused Transmit AIS-P (Downstream) upon LOF Transmit AIS-P (Downstream) upon LOS Transmit AIS-P (Downstream) Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Transmit Path AIS upon Declaration of the Section Trace Message Unstable Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block), anytime it declares the Section Trace Message Unstable defect condition within the incoming STS-1 or STS-3 data-stream. ` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever (and for the duration that) it declares the Section Trace Message Unstable defect condition. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever (and for the duration that) it declares the Section Trace Message Unstable defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 6 - Transmit Path AIS (AIS-P) upon Declaration of the Section Trace Message Mismatch Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor blocks), anytime (and for the duration that) it declares the Section Trace Message Mismatch defect condition within the incoming STS-1/STS-3 data stream. ` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the Section Trace Mismatch defect condition. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever (and for the duration that) it declares the Section Trace Message Mismatch defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 5 - Transmit Path AIS upon declaration of the Signal Failure (SF) defect condition This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block), anytime (and for the duration that) it declares the SF defect condition. ` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the downstream traffic) upon declaration of the SF defect. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) anytime (and for the duration that) it declares the SF defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 4 - Transmit Path AIS upon declaration of the Signal Degrade (SD) defect 102 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block) anytime (and for the duration that) it declares the SD defect condition. ` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the downstream traffic) upon declaration of the SD defect. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) anytime (and for the duration that) it declares the SD defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 3 - Unused BIT 2 - Transmit Path AIS upon declaration of the Loss of Frame (LOF) defect This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block), anytime (and for the duration that) it declares the LOF defect condition. ` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the downstream traffic) upon declaration of the LOF defect. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) anytime (and for the duration that) it declares the LOF defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 1 - Transmit Path AIS upon declaration of the Loss of Signal (LOS) defect This READ/WRITE bit-field is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block), anytime (and for the duration that) it declares the LOS defect condition. ` 0 - Does not configure the Receive STS-1/STS-3 TOH Processor block to transmit the AIS-P indicator (via the downstream traffic) anytime it declares the LOS defect condition. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) anytime (and for the duration that) it declares the LOS defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 0 - Automatic Transmission of AIS-P Enable This READ/WRITE bit-field serves two purposes. It is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the Path AIS (AIS-P) indicator, via the down-stream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block), upon detection of an SF, SD, Section Trace Mismatch, Section Trace Unstable, LOF or LOS defect conditions. It also is used to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit a Path AIS (AISP) Indicator via the downstream traffic (e.g., towards the Receive STS-1/STS-3 POH Processor block) anytime it declares the AIS-L defect condition within the incoming STS-1/STS-3 datastream. ` 0 - Configures the Receive STS-1/STS-3 TOH Processor block to NOT automatically transmit the AIS-P indicator (via the downstream traffic) upon declaration of the AIS-L defect condition or any of the above-mentioned defect conditions. ` 1 - Configures the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) upon declaration of the AIS-L defect or any of the above-mentioned defect conditions. NOTE: The user must also set the corresponding bit-fields (within this register) to 1 in order to configure the Receive STS-1/STS-3 TOH Processor block to automatically transmit the AIS-P indicator upon declaration of a given alarm/defect condition. 103 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 127: RECEIVE STS-1/STS-3 TRANSPORT - AUTO AIS (IN DOWNSTREAM T1/E1S) CONTROL REGISTER (ADDRESS LOCATION= 0X026B) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit AIS (via Downstream T1/E1s) upon LOS Transmit AIS (via Downstream T1/E1s) upon LOF Transmit AIS (via Downstream T1/E1s) upon SD Transmit AIS (via Downstream T1/E1s) upon SF Unused Transmit AIS (via Downstream T1/E1s) Enable R/O R/O R/W R/W R/W R/W R/O R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Unused BIT 5 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the LOS (Loss of Signal) defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the LOS defect condition.3 ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1/STS-3 TOH Processor block declares the LOS defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the LOS defect condition. BIT 4 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the LOF (Loss of Frame) defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the LOF defect condition. BIT 3 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the SD (Signal Degrade) defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the SD defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1/STS-3 TOH Processor block declares the SD defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the SD defect condition. BIT 2 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the Signal Failure (SF) defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the SF defect condition. ` 0 - Does not configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1/STS-3 TOH Processor block declares the SF defect condition. 104 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares the SF defect condition. BIT 1 - Unused BIT 0 - Automatic Transmission of DS1/E1 AIS (via the downstream DS1/E1s) Enable This READ/WRITE bit-field serves two purposes.It is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, upon declaration of either the SF, SD, LOS or LOF defect conditions via the Receive STS-1/STS-3 TOH Processor block. It also is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicator, via its outbound DS1/E1 signals, upon declaration of the AIS-L defect condition, via the Receive STS-1/STS-3 TOH Processor block. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicator, whenever the Receive STS-1/STS-3 TOH Processor block declares either the LOS, LOF, SD, SF or AIS-L defect conditions. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicator, whenever (and for the duration that) the Receive STS-1/STS-3 TOH Processor block declares either the LOS, LOF, SD, SF or AIS-L defect conditions. TABLE 128: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X026E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive A1, A2 Byte Error Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive A1, A2 Byte Error Count Register - MSB Register This RESET-upon-READ register, along with the Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register - Byte 0 presents a 16-bit representation of the total number of A1 and A2 byte errors that the Receive STS-1/STS-3 TOH Processor block has detected (within the incoming STS-1/STS-3 data-stream) since the last read of this register. NOTE: This register contains the MSB (Most Significant Byte) of this 16-bit expression. TABLE 129: RECEIVE STS-1/STS-3 TRANSPORT - A1, A2 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X026F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive A1, A2 Byte Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive A1, A2 Byte Error Count Register - LSB Register This RESET-upon-READ register, along with the Receive STS-1/STS-3 Transport - A1, A2 Byte Error Count Register - Byte 1 presents a 16-bit representation of the total number of A1 and A2 byte errors that the Receive STS-1/STS-3 TOH Processor block has detected (within the incoming STS-1/STS-3 data-stream) since the last read of this register. NOTE: This register contains the LSB (Least Significant Byte) of this 16-bit expression. 2.4 RECEIVE STS-1 POH PROCESSOR BLOCK REGISTERS The register map for the Receive STS-1 POH Processor Block is presented in the Table below. Additionally, a detailed description of each of the Receive STS-1/STS-3 POH Processor block registers is presented below. 105 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328, with the Receive STS-1 POH Processor block highlighted is presented below in Figure 4. FIGURE 4. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE RECEIVE STS-1 POH PROCESSOR BLOCK HIGHLIGHTED Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 TABLE 130: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 2 (ADDRESS = 0X0281) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Payload_Type[1:0] R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:2] - Unused BIT [1:0] - Payload_Type[1:0] 106 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 131: RECEIVE STS-1 PATH - RECEIVE CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0283) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 CheckStuff RDI-PType REI-PError Type B3 Error Type R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT 3 - Check (Pointer Adjustment) Stuff Select This READ/WRITE bit-field is used to enable/disable the SONET standard recommendation that a pointer increment or decrement operation, detected within 3 SONET frames of a previous pointer adjustment operation (e.g., negative stuff, positive stuff) is ignored. ` 0 - Disables this SONET standard implementation. In this mode, all pointer-adjustment operations that are detected will be accepted. ` 1 - Enables this SONET standard implementation. In this mode, all pointer-adjustment operations that are detected within 3 SONET frame periods of a previous pointer-adjustment operation will be ignored. BIT 2 - Path - Remote Defect Indicator Type Select This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to support either the SingleBit or the Enhanced RDI-P form of signaling, as described below. ` 0 - Configures the Receive STS-1 POH Processor block to support Single-Bit RDI-P. In this mode, the Receive STS-1 POH Processor block will only monitor BIT 5, within the G1 byte (of the incoming SPE data), in order to declare and clear the RDI-P defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to support Enhanced RDI-P (ERDI-P). In this mode, the Receive STS-1 POH Processor block will monitor bits 5, 6 and 7, within the G1 byte, in order to declare and clear the RDI-P defect condition. BIT 1 - REI-P Error Type This READ/WRITE bit-field is used to specify how the Receive STS-1 POH Processor block will count (or tally) REI-P events, for Performance Monitoring purposes. The user can configure the Receive STS-1 POH Processor block to increment REI-P events on either a per-bit or per-frame basis. If the user configures the Receive STS-1 POH Processor block to increment REI-P events on a per-bit basis, then it will increment the Receive Path REI-P Error Count register by the value of the lower nibble within the G1 byte of the incoming STS-1/STS-3 data-stream. If the user configures the Receive STS-1 POH Processor block to increment REI-P events on a per-frame basis, then it will increment the Receive Path REI-P Error Count register each time it receives an STS-1/STS-3 frame, in which the lower nibble of the G1 byte (bits 1 through 4) are set to a non-zero value. ` 0 - Configures the Receive STS-1 POH Processor block to count or tally REI-P events on a per-bit basis. ` 1 - Configures the Receive STS-1 POH Processor block to count or tally REI-P events on a per-frame basis. BIT 0 - B3 Error Type This READ/WRITE bit-field is used to specify how the Receive STS-1 POH Processor block will count (or tally) B3 byte errors, for Performance Monitoring purposes. The user can configure the Receive STS-1 POH Processor block to increment B3 byte errors on either a per-bit or per-frame basis. If the user configures the Receive STS-1 POH Processor block to increment B3 byte errors on a per-bit basis, then it will increment the Receive Path B3 Byte Error Count register by the number of bits (within the B3 byte value) that is in error. If the user configures the Receive STS-1 POH Processor block to increment B3 byte errors on a per-frame basis, then it will increment the Receive Path B3 Byte Error Count register each time it receives an STS-1/STS-3 frame that contains an erred B3 byte. ` 0 - Configures the Receive STS-1 POH Processor block to count B3 byte errors on a per-bit basis ` 1 - Configures the Receive STS-1 POH Processor block to count B3 byte errors on a per-frame basis. 107 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 132: RECEIVE STS-1 PATH - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0286) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Unused BIT 0 Path Trace Message Unstable Defect Declared R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:1] - Unused BIT 0 - Path Trace Message Unstable Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the Path Trace Message Unstable defect condition. The Receive STS-1 POH Processor block will declare the Path Trace Message Unstable defect condition, whenever the Path Trace Message Unstable counter reaches the value 8. The Path Trace Message Unstable counter will be incremented for each time that it receives a Path Trace message that differs from the previously received message. The Path Trace Unstable counter is cleared to 0 whenever the Receive STS-1 POH Processor block has received a given Path Trace Message 3 (or 5) consecutive times. NOTE: Receiving a given Path Trace Message 3 (or 5) consecutive times also sets this bit-field to 0 ` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the Path Trace Message Unstable defect. ` 1 - Indicates that the Receive STS-1 POH Processor blolck is currently declaring the Path Trace Message Unstable defect condition. TABLE 133: RECEIVE STS-1 PATH - SONET RECEIVE POH STATUS - BYTE 0 (ADDRESS LOCATION= 0X0287) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 TIM-P Defect Declared C2 Byte UnstableDefect Declared UNEQ-PDefectDeclared PLM-PDefectDeclared RDI-PDefectDeclared RDI-P UnstableCondition LOP-PDefectDeclared AIS-PDefectDeclared R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - Trace Identification Mismatch (TIM-P) Defect Indicator This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the Path Trace Identification Mismatch (TIM-P) defect condition. The Receive STS-1 POH Processor block will declare the TIM-P defect condition, when none of the received 64-byte string (received via the J1 byte, within the incoming STS1/STS-3 data-stream) matches the expected 64 byte message.The Receive STS-1 POH Processor block will clear the TIM-P defect condition, when 80% of the received 64 byte string (received via the J1 byte) matches the expected 64 byte message. ` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the TIM-P defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the TIM-P defect condition. BIT 6 - C2 Byte (Path Signal Label Byte) Unstable Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the Path Signal Label Byte Unstable defect condition. The Receive STS-1 POH Processor block will declare the C2 (Path Signal Label Byte) Unstable defect condition, whenever the C2 Byte Unstable counter reaches the value 5. The C2 Byte Unstable counter will be incremented for each time that it receives an SPE with a C2 byte value that differs from the previously received C2 byte value. The C2 Byte Unstable counter is cleared to 0 whenever the Receive STS-1 POH Processor block has received 3 (or 5) consecutive SPEs that each contains the same C2 byte 108 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS value.Note:Receiving a given C2 byte value in 3 (or 5) consecutive SPEs also sets this bit-field to 0. ` 0 - Indicates that the Receive STS-1 POH Processor block is currently NOT declaring the C2 (Path Signal Label Byte) Unstable defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the C2 (Path Signal Label Byte) Unstable defect condition. BIT 5 - Path - Unequipped (UNEQ-P) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the UNEQ-P defect condition. The Receive STS-1 POH Processor block will declare the UNEQ-P defect condition, anytime that it receives at least five (5) consecutive STS-1/STS-3 frames, in which the C2 byte was set to the value 0x00 (which indicates that the SPE is Unequipped). The Receive STS-1 POH Processor block will clear the UNEQ-P defect condition, if it receives at least five (5) consecutive STS-1/STS-3 frames, in which the C2 byte was set to a value other than 0x00. ` 0 - Indicates that the Receive STS-1 POH Processor block is currently NOT declaring the UNEQ-P defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the UNEQ-P defect condition. NOTE: :The Receive STS-1 POH Processor block will not declare the UNEQ-P defect condition if it configured to expect to receive STS-1/STS-3 frames with C2 bytes being set to 0x00 (e.g., if the Receive STS-1 Path Expected Path Label Value Register -Address Location= 0x0297) is set to 0x00. BIT 4 - Path Payload Mismatch (PLM-P) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the PLM-P defect condition.The Receive STS-1 POH Processor block will declare the PLM-P defect condition, if it receives at least five (5) consecutive STS-1/STS-3 frames, in which the C2 byte was set to a value other than that which it is expecting to receive. Whenever the Receive STS-1 POH Processor block is determining whether or not it should declare the PLM-P defect, it will check the contents of the following two registers. • The Receive STS-1 Path - Received Path Label Value Register (Address Location= 0xN196). • The Receive STS-1 Path - Expected Path Label Value Register (Address Location= 0xN197). The Receive STS-1 Path - Expected Path Label Value Register contains the value of the C2 bytes, that the Receive STS-1 POH Processor blocks expects to receive.The Receive STS-1 Path - Received Path Label Value Register contains the value of the C2 byte, that the Receive STS-1 POH Processor block has most received validated (by receiving this same C2 byte in five consecutive STS-1/STS-3 frames). The Receive STS-1 POH Processor block will declare the PLM-P defect condition if the contents of these two register do not match. The Receive STS-1 POH Processor block will clear the PLM-P defect condition if whenever the contents of these two registers do match. ` 0 - Indicates that the Receive STS-1 POH Processor block is currently NOT declaring the PLM-P defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the PLM-P defect condition NOTE: The Receive STS-1 POH Processor block will clear the PLM-P defect, upon declaring the UNEQ-P defect condition. BIT 3 - Path Remote Defect Indicator (RDI-P) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the RDI-P defect condition. If the Receive STS-1 POH Processor block is configured to support the Single-bit RDI-P function, then it will declare the RDI-P defect condition if BIT 5 (within the G1 byte of the incoming STS-1/STS-3 frame) is set to 1 for RDI-P_THRD number of incoming consecutive STS-1/STS-3 frames. If the Receive STS-1 POH Processor block is configured to support the Enhanced RDI-P (ERDI-P) function, then it will declare the RDI-P defect condition if Bits 5, 6 and 7 (within the G1 byte of the incoming STS-1/STS-3 frame) are set to [0, 1, 0], [1, 0, 1] or [1, 1, 0] for RDI-P_THRD number of consecutive STS-1/STS-3 frames. ` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the RDI-P defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the RDI-P defect condition. NOTE: The user can specify the value for RDI-P_THRD by writing the appropriate data into Bits 3 through 0 (RDI-P THRD) within the Receive STS-1 Path - SONET Receive RDI-P Register (Address Location= 0x0293). BIT 2 - RDI-P (Path - Remote Defect Indicator) Unstable Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the RDI-P Unstable defect condition. The Receive STS-1 POH Processor block will declare a RDI-P I Unstable defect 109 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 condition whenever the RDI-P Unstable Counter reaches the value RDI-P THRD. The RDI-P Unstable counter is incremented for each time that the Receive STS-1 POH Processor block receives an RDI-P value that differs from that of the previous STS-1/STS-3 frame. The RDI-P Unstable counter is cleared to 0 whenever the same RDI-P value is received in RDI-P_THRD consecutive STS-1/STS-3 frames. NOTE: Receiving a given RDI-P value, in RDI-P_THRD consecutive STS-1/STS-3 frames also clears this bit-field to 0. ` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the RDI-P Unstable defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the RDI-P Unstable defect condition. NOTE: The user can specify the value for RDI-P_THRD by writing the appropriate data into Bits 3 through 0 (RDI-P THRD) within the Receive STS-1 Path - SONET Receive RDI-P Register (Address Location= 0x0293). BIT 1 - Loss of Pointer Indicator (LOP-P) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the LOP-P (Loss of Pointer) defect condition. The Receive STS-1 POH Processor block will declare the LOP-P defect condition, if it cannot detect a valid pointer (H1 and H2 bytes, within the TOH) within 8 to 10 consecutive SONET frames. Further, the Receive STS-1 POH Processor block will declare the LOP-P defect condition, if it detects 8 to 10 consecutive NDF events. The Receive STS-1 POH Processor block will clear the LOP-P defect condition, whenever it detects valid pointer bytes (e.g., the H1 and H2 bytes, within the TOH) and normal NDF value for three consecutive incoming STS-1/STS-3 frames. ` 0 - Indicates that the Receive STS-1 POH Processor block is NOT declaring the LOP-P defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the LOP-P defect condition. BIT 0 - Path AIS (AIS-P) Defect Declared This READ-ONLY bit-field indicates whether or not the Receive STS-1 POH Processor block is currently declaring the AIS-P defect condition. The Receive STS-1 POH Processor block will declare the AIS-P defect condition if it detects all of the following conditions within three consecutive incoming STS-1/STS-3 frames.· • The H1, H2 and H3 bytes are set to an All Ones pattern.· • The entire SPE is set to an All Ones pattern. The Receive STS-1 POH Processor block will clear the AIS-P defect condition when it detects a valid STS-1/STS-3 pointer (H1 and H2 bytes) and a set or normal NDF for three consecutive STS-1/STS-3 frames. ` 0 - Indicates that the Receive STS-1 POH Processor block is NOT currently declaring the AIS-P defect condition. ` 1 - Indicates that the Receive STS-1 POH Processor block is currently declaring the AIS-P defect condition NOTE: The Receive STS-1 POH Processor block will NOT declare the LOP-P defect condition if it detects an All Ones pattern in the H1, H2 and H3 bytes. It will, instead, declare the AIS-P defect condition. TABLE 134: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 2 (ADDRESS LOCATION= 0X0289) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Detection of AIS Pointer Interrupt Status Detection of Pointer Change Interrupt Status Unused Change in TIM-P Defect Condition Interrupt Status Change in Path Trace Message Unstable Defect Condition Interrupt Status R/O R/O R/O RUR RUR R/O RUR RUR 0 0 0 0 0 0 0 0 BIT [7:5] - Unused BIT 4 - Detection of AIS Pointer Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of AIS Pointer interrupt has occurred since the last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate this interrupt anytime it detects an AIS Pointer in the incoming STS-1/STS-3 data stream. 110 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: An AIS Pointer is defined as a condition in which both the H1 and H2 bytes (within the TOH) are each set to an All Ones pattern. ` 0 - Indicates that the Detection of AIS Pointer interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of AIS Pointer interrupt has occurred since the last read of this register. BIT 3 - Detection of Pointer Change Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of Pointer Change Interrupt has occurred since the last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it accepts a new pointer value (e.g., H1 and H2 bytes, in the TOH bytes). ` 0 - Indicates that the Detection of Pointer Change Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of Pointer Change Interrupt has occurred since the last read of this register. BIT 2 - Unused BIT 1 - Change in TIM-P (Trace Identification Mismatch) Defect Condition Interrupt This RESET-upon-READ bit-field indicates whether or not the Change in TIM-P Defect Condition interrupt has occurred since the last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • Whenever the Receive STS-1 POH Processor block declares the TIM-P defect condition. • Whenever the Receive STS-1 POH Processor block clears the TIM-P defect condition. ` 0 - Indicates that the Change in TIM-P Defect Condition Interrupt has not occurred since the last read of this register. ` 1 - Indicates that the Change in TIM-P Defect Condition Interrupt has occurred since the last read of this register. BIT 0 - Change in Path Trace Identification Message Unstable Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in Path Trace Message Unstable Defect Condition Interrupt has occurred since the last read of this register.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate this interrupt in response to either of the following events. • Whenever the Receive STS-1 POH Processor block declare the Path Trace Message Unstable Defect Condition. • Whenever the Receive condition. STS-1 POH Processor block clears the Path Trace Message Unstable defect ` 0 - Indicates that the Change in Path Trace Message Unstable Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in Path Trace Message Unstable Defect Condition Interrupt has occurred since the last read of this register. TABLE 135: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 1 (ADDRESS LOCATION= 0X028A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 New Path Trace Message Interrupt Status Detection of REI-P Event Interrupt Status Change in UNEQ-P Defect Condition Interrupt Status Change in PLM-P Defect Condition Interrupt Status New C2 Byte Interrupt Status Change in C2 Byte Unstable Defect Condition Interrupt Status Change in RDI-P Unstable Defect Condition Interrupt Status New RDI-P Value Interrupt Status RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - New Path Trace Message Interrupt Status This RESET-upon-READ bit-field indicates whether or not the New Path Trace Message Interrupt has occurred since the last read of this register. 111 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has accepted (or validated) a new Path Trace Message. ` 0 - Indicates that the New Path Trace Message Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the New Path Trace Message Interrupt has occurred since the last read of this register. BIT 6 - Detection of REI-P Event Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of REI-P Event Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects an REI-P event within the incoming STS-1/STS-3 data-stream. ` 0 - Indicates that the Detection of REI-P Event Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of REI-P Event Interrupt has occurred since the last read of this register. BIT 5 - Change in UNEQ-P (Path - Unequipped) Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in UNEQ-P Defect Condition interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following conditions. • When the Receive STS-1 POH Processor block declares the UNEQ-P Defect Condition. • When the Receive STS-1 POH Processor block clears the UNEQ-P Defect Condition. ` 0 - Indicates that the Change in UNEQ-P Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in UNEQ-P Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine if the Receive STS-1 POH Processor block is currently declaring the UNEQ-P defect condition by reading out the state of BIT 5 (UNEQ-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 Register (Address Location= 0xN187). BIT 4 - Change in PLM-P (Path - Payload Mismatch) Defect Condition Interrupt Status This RESET-upon-READ bit indicates whether or not the Change in PLM-P Defect Condition interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following conditions. • When the Receive STS-1 POH Processor block declares the PLM-P Defect Condition. • When the Receive STS-1 POH Processor block clears the PLM-P Defect Condition. ` 0 - Indicates that the Change in PLM-P Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in PLM-P Defect Condition Interrupt has occurred since the last read of this register. BIT 3 - New C2 Byte Interrupt Status This RESET-upon-READ bit-field indicates whether or not the New C2 Byte Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has accepted a new C2 byte. ` 0 - Indicates that the New C2 Byte Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the New C2 Byte Interrupt has occurred since the last read of this register. BIT 2 - Change in C2 Byte Unstable Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in C2 Byte Unstable Defect Condition Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • When the Receive STS-1 POH Processor block declares the C2 Byte Unstable defect condition. • When the Receive STS-1 POH Processor block clears the C2 Byte Unstable defect condition. 112 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 0 - Indicates that the Change in C2 Byte Unstable Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in C2 Byte Unstable Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine whether or not the Receive STS-1 POH Processor block is currently declaring the C2 Byte Unstable Defect Condition by reading out the state of BIT6 (C2 Byte Unstable Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 Register (Address Location= 0x0287). BIT 1 - Change in RDI-P Unstable Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in RDI-P Unstable Defect Condition interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following conditions. • When the Receive STS-1 POH Processor block declares an RDI-P Unstable defect condition. • When the Receive STS-1 POH Processor block clears the RDI-P Unstable defect condition. ` 0 - Indicates that the Change in RDI-P Unstable Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in RDI-P Unstable Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine the current state of RDI-P Unstable Defect condition by reading out the state of BIT 2 (RDI-P Unstable Defect Condition) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 Register (Address Location= 0x0287). BIT 0 - New RDI-P Value Interrupt Status This RESET-upon-READ bit-field indicates whether or not the New RDI-P Value interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate this interrupt anytime it receives and validates a new RDI-P value. ` 0 - Indicates that the New RDI-P Value Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the New RDI-P Value Interrupt has occurred since the last read of this register. NOTE: The user can obtain the New RDI-P Value by reading out the contents of the RDI-P ACCEPT[2:0] bit-fields. These bit-fields are located in Bits 6 through 4, within the Receive STS-1 Path - SONET Receive RDI-P Register (Address Location= 0x0293). TABLE 136: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT STATUS - BYTE 0 (ADDRESS LOCATION= 0X028B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Detection of B3 Byte Error Interrupt Status Detection of New Pointer Interrupt Status Detection of Unknown Pointer Interrupt Status Detection of Pointer Decrement Interrupt Status Detection of Pointer Increment Interrupt Status Detection of NDF Pointer Interrupt Status Change of LOP-P Defect Condition Interrupt Status Change of AIS-P Defect Condition Interrupt Status RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - Detection of B3 Byte Error Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of B3 Byte Error Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a B3 byte error in the incoming STS-1/STS-3 data stream. ` 0 - Indicates that the Detection of B3 Byte Error Interrupt has NOT occurred since the last read of this interrupt. 113 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 1 - Indicates that the Detection of B3 Byte Error Interrupt has occurred since the last read of this interrupt. BIT 6 - Detection of New Pointer Interrupt Status This RESET-upon-READ indicates whether the Detection of New Pointer interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a new pointer value in the incoming STS-1/STS-3 frame. NOTE: Pointer Adjustments with NDF will not generate this interrupt. ` 0 - Indicates that the Detection of New Pointer Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of New Pointer Interrupt has occurred since the last read of this register. BIT 5 - Detection of Unknown Pointer Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of Unknown Pointer interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime that it detects a pointer that does not fit into any of the following categories. • An Increment Pointer • A Decrement Pointer • An NDF Pointer • An AIS (e.g., All Ones) Pointer • New Pointer ` 0 - Indicates that the Detection of Unknown Pointer interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of Unknown Pointer interrupt has occurred since the last read of this register. BIT 4 - Detection of Pointer Decrement Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of Pointer Decrement Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a Pointer Decrement event. ` 0 - Indicates that the Detection of Pointer Decrement interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of Pointer Decrement interrupt has occurred since the last read of this register. BIT 3 - Detection of Pointer Increment Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of Pointer Increment Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a Pointer Increment event. ` 0 - Indicates that the Detection of Pointer Increment interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of Pointer Increment interrupt has occurred since the last read of this register. BIT 2 - Detection of NDF Pointer Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Detection of NDF Pointer interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects an NDF Pointer event. ` 0 - Indicates that the Detection of NDF Pointer interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of NDF Pointer interrupt has occurred since the last read of this register. BIT 1 - Change of LOP-P Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change in LOP-P Defect Condition interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • When the Receive STS-1 POH Processor block declares the LOP-P defect condition. 114 PRELIMINARY REV. P1.0.6 • XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ·When the Receive STS-1 POH Processor block clears the LOP-P defect condition. ` 0 - Indicates that the Change in LOP-P Defect Condition interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in LOP-P Defect Condition interrupt has occurred since the last read of this register. NOTE: The user can determine if the Receive STS-1 POH Processor block is currently declaring the LOP-P defect condition by reading out the state of BIT 1 (LOP-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 Register (Address Location=0x0287). BIT 0 - Change of AIS-P Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Change of AIS-P Defect Condition Interrupt has occurred since the last read of this register. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • Whenever the Receive STS-1 POH Processor block declares the AIS-P defect condition. • Whenever the Receive STS-1 POH Processor block clears the AIS-P defect condition. ` 0 - Indicates that the Change of AIS-P Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of AIS-P Defect Condition Interrupt has occurred since the last read of this register. NOTE: The user can determine if the Receive STS-1 POH Processor block is currently declaring the AIS-P defect condition by reading out the state of BIT 0 (AIS-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 Register (Address Location= 0x0287). TABLE 137: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 2 (ADDRESS LOCATION = 0X028D) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Detection of AIS Pointer Interrupt Enable Detection of Pointer Change Interrupt Enable Unused Change in TIM-P Defect Condition Interrupt Enable Change in Path Trace Message Unstable Defect Condition Interrupt Enable R/O R/O R/O R/W R/W R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:5] - Unused BIT 4 - Detection of AIS Pointer Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of AIS Pointer interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects an AIS Pointer, in the incoming STS-1/STS-3 data stream. NOTE: An AIS Pointer is defined as a condition in which both the H1 and H2 bytes (within the TOH) are each set to an All Ones Pattern. ` 0 - Disables the Detection of AIS Pointer Interrupt. ` 1 - Enables the Detection of AIS Pointer Interrupt. BIT 3 - Detection of Pointer Change Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of Pointer Change Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has accepted a new pointer value. ` 0 - Disables the Detection of Pointer Change Interrupt. ` 1 - Enables the Detection of Pointer Change Interrupt. 115 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT 2 - Unused BIT 1 - Change in TIM-P (Trace Identification Mismatch) Defect Condition Interrupt This READ/WRITE bit-field is used to either enable or disable the Change in TIM-P Condition interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • If the TIM-P defect condition is declared. • If the TIM-P defect condition is cleared. ` 0 - Disables the Change in TIM-P Defect Condition Interrupt. ` 1 - Enables the Change in TIM-P Defect Condition Interrupt. BIT 0 - Change in Path Trace Message Unstable Defect Condition Interrupt Status This READ/WRITE bit-field is used to either enable or disable the Change in Path Trace Message Unstable Defect Condition Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • Whenever the Receive STS-1 POH Processor block declares the Path Trace Message Unstable Defect Condition.· Whenever the Receive STS-1 POH Processor block clears the Path Trace Message Unstable Defect Condition. ` 0 - Disables the Change in Path Trace Message Unstable Defect Condition interrupt. ` 1 - Enables the Change in Path Trace Message Unstable Defect Condition interrupt. TABLE 138: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 1 (ADDRESS LOCATION= 0X028E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 New Path Trace Message Interrupt Enable Detection of REI-P Event Interrupt Enable Change in UNEQ-P Defect Condition Interrupt Enable Change in PLM-P Defect Condition Interrupt Enable New C2 Byte Interrupt Enable Change in C2 Byte Unstable Defect Condition Interrupt Enable Change in RDI-P Unstable Defect Condition Interrupt Enable New RDIPValue Interrupt Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - New Path Trace Message Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the New Path Trace Message Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has accepted (or validated) and new Path Trace Message. ` 0 - Disables the New Path Trace Message Interrupt. ` 1 - Enables the New Path Trace Message Interrupt. BIT 6 - Detection of REI-P Event Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of REI-P Event Interrupt. If this interrupt is enabled, then he Receive STS-1 POH Processor block will generate an interrupt anytime it detects an REI-P condition in the coming STS-1/STS-3 data-stream. ` 0 - Disables the Detection of REI-P Event Interrupt. ` 1 - Enables the Detection of REI-P Event Interrupt. BIT 5 - Change in UNEQ-P (Path - Unequipped) Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change in UNEQ-P Defect Condition interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following conditions 116 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS • When the Receive STS-1 POH Processor block declares the UNEQ-P Defect Condition. • When the Receive STS-1 POH Processor block clears the UNEQ-P Defect Condition. ` 0 - Disables the Change in UNEQ-P Defect Condition Interrupt. ` 1 - Enables the Change in UNEQ-P Defect Condition Interrupt. BIT 4 - Change in PLM-P (Path - Payload Label Mismatch) Defect Condition Interrupt Enable This READ/WRITE bit is used to either enable or disable the Change in PLM-P Defect Condition interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following conditions. • Whenever the Receive STS-1 POH Processor block declares the PLM-P defect Condition. • Whenever the Receive STS-1 POH Processor block clears the PLM-P defect Condition. ` 0 - Disables the Change in PLM-P Defect Condition Interrupt. ` 1 - Enables the Change in PLM-P Defect Condition Interrupt. BIT 3 - New C2 Byte Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the New C2 Byte Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it has accepted a new C2 byte. ` 0 - Disables the New C2 Byte Interrupt. ` 1 - Enables the New C2 Byte Interrupt. NOTE: The user can obtain the value of this New C2 byte by reading the contents of the Receive STS-1 Path Received Path Label Value Register (Address Location= 0x0296). BIT 2 - Change in C2 Byte Unstable Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change in C2 Byte Unstable Condition Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • When the Receive STS-1 POH Processor block declares the C2 Byte Unstable defect condition. • When the Receive STS-1 POH Processor block clears the C2 Byte Unstable defect condition. ` 0 - Disables the Change in C2 Byte Unstable Defect Condition Interrupt. ` 1 - Enables the Change in C2 Byte Unstable Defect Condition Interrupt. BIT 1 - Change in RDI-P Unstable Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change in RDI-P Unstable Defect Condition interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following conditions. • Whenever the Receive STS-1 POH Processor block declares the RDI-P Unstable defect condition. • Whenever the Receive STS-1 POH Processor block clears the RDI-P Unstable defect condition. ` 0 - Disables the Change in RDI-P Unstable Defect Condition Interrupt. ` 1 - Enables the Change in RDI-P Unstable Defect Condition Interrupt. BIT 0 - New RDI-P Value Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the New RDI-P Value interrupt.If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate this interrupt anytime it receives and validates a new RDIP value. ` 0 - Disables the New RDI-P Value Interrupt. ` 1 - Enable the New RDI-P Value Interrupt. 117 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 139: RECEIVE STS-1 PATH - SONET RECEIVE PATH INTERRUPT ENABLE - BYTE 0 (ADDRESS LOCATION= 0X028F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Detection of B3 Byte ErrorInterruptEnable Detection of New Pointer Interrupt Enable Detection of Unknown Pointer Interrupt Enable Detection of Pointer Decrement Interrupt Enable Detection of Pointer IncrementInterrupt Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Detection of Change of Change of NDF PointerLOP-P AIS-P Interrupt DefectCondi- DefectCondiEnable tion Interrupt tionInterrupt Enable Enable BIT 7 - Detection of B3 Byte Error Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of B3 Byte Error Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a B3-byte error in the incoming STS-1/STS-3 data-stream. ` 0 - Disables the Detection of B3 Byte Error interrupt. ` 1 - Enables the Detection of B3 Byte Error interrupt. BIT 6 - Detection of New Pointer Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of New Pointer interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a new pointer value in the incoming STS-1/STS-3 frame. NOTE: :Pointer Adjustments with NDF will not generate this interrupt. ` 0 - Disables the Detection of New Pointer Interrupt. ` 1 - Enables the Detection of New Pointer Interrupt. BIT 5 - Detection of Unknown Pointer Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of Unknown Pointer interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a Pointer Adjustment that does not fit into any of the following categories.· An Increment Pointer.· A Decrement Pointer· An NDF Pointer· AIS Pointer· New Pointer. ` 0 - Disables the Detection of Unknown Pointer Interrupt. ` 1 - Enables the Detection of Unknown Pointer Interrupt. BIT 4 - Detection of Pointer Decrement Interrupt Enable This READ/WRITE bit-field is used to enable or disable the Detection of Pointer Decrement Interrupt. If this interrupt is enabled, then the Receive STS-1/STS-3 TOH Processor block will generate an interrupt anytime it detects a Pointer-Decrement event. ` 0 - Disables the Detection of Pointer Decrement Interrupt. ` 1 - Enables the Detection of Pointer Decrement Interrupt. BIT 3 - Detection of Pointer Increment Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of Pointer Increment Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects a Pointer Increment event. ` 0 - Disables the Detection of Pointer Increment Interrupt. ` 1 - Enables the Detection of Pointer Increment Interrupt. BIT 2 - Detection of NDF Pointer Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Detection of NDF Pointer Interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt anytime it detects 118 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS an NDF Pointer event. ` 0 - Disables the Detection of NDF Pointer interrupt. ` 1 - Enables the Detection of NDF Pointer interrupt. BIT 1 - Change of LOP-P Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change in LOP (Loss of Pointer) Condition interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • When the Receive STS-1 POH Processor block declares the LOP-P defect condition condition. • When the Receive STS-1 POH Processor block clears the LOP-P defect condition. ` 0 - Disable the Change of LOP-P Defect Condition Interrupt. ` 1 - Enables the Change of LOP-P Defect Condition Interrupt. NOTE: The user can determine the current state of the LOP-P Defect condition by reading out the contents of BIT 1 (LOP-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 (Address Location= 0x0287). BIT 0 - Change of AIS-P Defect Condition Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of AIS-P (Path AIS) Defect Condition interrupt. If this interrupt is enabled, then the Receive STS-1 POH Processor block will generate an interrupt in response to either of the following events. • When the Receive STS-1 POH Processor block declares the AIS-P Defect condition. • When the Receive STS-1 POH Processor block clears the AIS-P Defect condition. ` 0 - Disables the Change of AIS-P Defect Condition Interrupt. ` 1 - Enables the Change of AIS-P Defect Condition Interrupt. NOTE: The user can determine the current state of the AIS-P Defect Condition by reading out the contents of BIT 0 (AIS-P Defect Declared) within the Receive STS-1 Path - SONET Receive POH Status - Byte 0 (Address Location= 0x0287). TABLE 140: RECEIVE STS-1 PATH - SONET RECEIVE RDI-P REGISTER (ADDRESS LOCATION= 0X0293) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 RDI-P_ACCEPT[2:0] BIT 2 BIT 1 BIT 0 RDI-P THRESHOLD[3:0] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Unused BIT [6:4] - Accepted RDI-P Value These READ-ONLY bit-fields contain the value of the most recently accepted RDI-P (e.g., bits 5, 6 and 7 within the G1 byte) value that has been accepted by the Receive STS-1 POH Processor block. NOTE: A given RDI-P value will be accepted by the Receive STS-1 POH Processor block, if this RDI-P value has been consistently received in RDI-P THRESHOLD[3:0] number of STS-1/STS-3 frames. BIT [3:0] - RDI-P Threshold[3:0] These READ/WRITE bit-fields are used to defined the RDI-P Acceptance Threshold for the Receive STS-1 POH Processor Block. The RDI-P Acceptance Threshold is the number of consecutive STS-1/STS-3 frames, in which the Receive STS-1 POH Processor block must receive a given RDI-P value, before it accepts or validates it. The most recently accepted RDI-P value is written into the RDI-P ACCEPT[2:0] bit-fields, within this register. 119 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 141: RECEIVE STS-1 PATH - RECEIVED PATH LABEL VALUE (ADDRESS LOCATION= 0X0296) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Received_C2_Byte_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 1 1 1 1 1 1 1 1 BIT [7:0] - Received Filtered C2 Byte Value These READ-ONLY bit-fields contain the value of the most recently accepted C2 byte, via the Receive STS-1 POH Processor block. The Receive STS-1 POH Processor block will accept a C2 byte value (and load it into these bit-fields) if it has received a consistent C2 byte, in five (5) consecutive STS-1/STS-3 frames. NOTE: The Receive STS-1 POH Processor block uses this register, along the Receive STS-1 Path - Expected Path Label Value Register (Address Location = 0x0297), when declaring or clearing the UNEQ-P and PLM-P defect conditions. TABLE 142: RECEIVE STS-1 PATH - EXPECTED PATH LABEL VALUE (ADDRESS LOCATION= 0X0297) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Expected_C2_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT [7:0] - Expected C2 Byte Value These READ/WRITE bit-fields are used to specify the C2 (Path Label Byte) value, that the Receive STS-1 POH Processor block should expect when declaring or clearing the UNEQ-P and PLM-P defect conditions. If the contents of the Received C2 Byte Value[7:0] (see Receive STS-1 Path - Received Path Label Value register) matches the contents in these register, then the Receive STS-1 POH will not declare any defect conditions. NOTE: The Receive STS-1 POH Processor block uses this register, along with the Receive STS-1 Path - Receive Path Label Value Register (Address Location = 0x0296), when declaring or clearing the UNEQ-P and PLM-P defect conditions. TABLE 143: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X0298) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B3_Byte_Error_Count[31:24] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B3 Byte Error Count - MSB This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte error. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3 SPE) that are in error. 2. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred B3 byte. 120 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 144: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X0299) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B3_Byte_Error_Count[23:16] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B3 Byte Error Count (Bits 23 through 16) This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 3, 1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte error. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3 SPE) that are in error. 2. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred B3 byte. TABLE 145: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B3_Byte_Error_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B3 Byte Error Count - (Bits 15 through 8) This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 3, 2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte error. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3 SPE) that are in error. 2. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred B3 byte. TABLE 146: RECEIVE STS-1 PATH - B3 BYTE ERROR COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B3_Byte_Error_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - B3 Byte Error Count - LSB This RESET-upon-READ register, along with Receive STS-1 Path - B3 Byte Error Count Register - Bytes 3 through 1 function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a B3 byte error. NOTES: 121 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 1. If the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-bit basis, then it will increment this 32 bit counter by the number of bits, within the B3 byte (of each incoming STS-1/STS-3 SPE) that are in error. 2. f the Receive STS-1 POH Processor block is configured to count B3 byte errors on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains an erred B3 byte. TABLE 147: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 3 (ADDRESS LOCATION= 0X029C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-P Event_Count[31:24] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-P Event Count - MSB This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 2 through 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the incoming STS-1/STS-3 SPE data-stream. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte within each incoming STS-1/STS-3 SPE. 2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a non-zero REI-P value. TABLE 148: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 2 (ADDRESS LOCATION= 0X029D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-P_Event_Count[23:16] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-P Event Count (Bits 23 through 16) This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 3, 1 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the inconing STS-1/STS-3 SPE data-stream. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte within each incoming STS-1/STS-3 frame. 2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a nonzero REI-P value. TABLE 149: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X029E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-P_Event_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 122 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT [7:0] - REI-P Event Count - (Bits 15 through 8) This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 3, 2 and 0, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the incoming STS-1/STS-3 SPE data-stream. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte within each incoming STS-1/STS-3 SPE. 2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a nonzero REI-P value TABLE 150: RECEIVE STS-1 PATH - REI-P EVENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X029F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-P_Event_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - REI-P Event Count - LSB This RESET-upon-READ register, along with Receive STS-1 Path - REI-P Error Count Register - Bytes 3 through 1, function as a 32 bit counter, which is incremented anytime the Receive STS-1 POH Processor block detects a Path Remote Error Indicator event within the incoming STS-1/STS-3 SPE data-stream. NOTES: 1. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-bit basis, then it will increment this 32 bit counter by the nibble-value within the REI-P field of the incoming G1 byte. 2. If the Receive STS-1 POH Processor block is configured to count REI-P events on a per-frame basis, then it will increment this 32 bit counter each time that it receives an STS-1/STS-3 SPE that contains a nonzero REI-P value. TABLE 151: RECEIVE STS-1 PATH - RECEIVE PATH TRACE MESSAGE BUFFER CONTROL REGISTER (ADDRESS LOCATION= 0X02A3) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 New Message Ready Receive Path Trace Message Buffer Read Select Receive Path Trace Message Accept Threshold Path Trace Message Alignment Type BIT 1 BIT 0 Receive Path Trace Message Length[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Unused BIT 5 - New Message Ready This READ/WRITE bit-field indicates whether or not the Receive Path Trace Message buffer has received a new expected value. ` 0 - Indicates NO new expected value has been downloaded into the receive J1 trace buffer. ` 1 - Indicates a new expected value has been downloaded into the receive J1 trace buffer and can be used to make comparisons with the accepted J1 message. BIT 4 - Receive Section Trace Message Buffer Read Selection This READ/WRITE bit-field is used to specify which of the following Receive Path Trace Message buffer segments to 123 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 read. a. The Actual Receive Path Trace Message Buffer. The Actual Receive Path Trace Message Buffer contains the contents of the most recently received (and accepted) Path Trace Message via the incoming STS-1/STS-3 data-stream. b. The Expected Receive Path Trace Message Buffer. The Expected Receive Path Trace Message Buffer contains the contents of the Path Trace Message that the user expects to receive. The contents of this particular buffer are usually specified by the user. ` 0 - Executing a READ to the Receive J1 Trace Buffer, will return contents within the Valid Message buffer. ` 1 - Executing a READ to the Receive J1 Trace Buffer, will return contents within the Expected Message Buffer. NOTE: In the case of the Receive STS-1 POH Processor block, the Receive J1 Trace Buffer is located at Address Location 0x0500 through 0x053F. BIT 3 - Path Trace Message Accept Threshold This READ/WRITE bit-field is used to select the number of consecutive times that the Receive STS-1 POH Processor block must receive a given Receive Trace Message, before it is accepted and loaded into the Receive Path Trace Message. ` 0 - The Receive STS-1 POH Processor block accepts the Path Trace Message after it has received it the third time in succession. ` 1 - The Receive SONET POH Processor block accepts the incoming Path Trace Message after it has received in the fifth time in succession. BIT 2 - Path Trace Message Alignment Type This READ/WRITE bit-field is used to specify have the Receive STS-1 POH Processor block will locate the boundary of the J1 Trace Message. ` 0 - Message boundary is indicated by Line Feed. ` 1 - Message boundary is indicated by the presence of a 1 in the MSB of a the first byte (within the J1 Trace Message). BIT [1:0] - Path Trace Message Length[1:0] These READ/WRITE bit-fields are used to specify the length of the Receive Path Trace Message that the Receive STS1 POH Processor block will receive. The relationship between the content of these bit-fields and the corresponding Receive Path Trace Message Length is presented below. Receive Trace Path Message Length MSG LENGTH[1:0] RESULTING PATH TRACE MESSAGE LENGTH 00 1 Byte 01 16 Bytes 10/11 64 Bytes TABLE 152: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 1 (ADDRESS LOCATION= 0X02A6) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Current_Pointer ValueMSB[9:8] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:2] - Unused BIT [1:0]Current Pointer Value - MSB These READ-ONLY bit-fields, along with that from the Receive STS-1 Path - Pointer Value - Byte 0 Register combine to reflect the current value of the pointer that the Receive STS-1 POH Processor block is using to locate the SPE within the incoming STS-1/STS-3 data stream.Note These register bits comprise the Upper Byte value of the Pointer Value. 124 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 153: RECEIVE STS-1 PATH - POINTER VALUE - BYTE 0 (ADDRESS LOCATION= 0X02A7) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Current_Pointer_Value_LSB[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Current Pointer Value - LSB These READ-ONLY bit-fields, along with that from the Receive STS-1 Path - Pointer Value - Byte 1 Register combine to reflect the current value of the pointer that the Receive STS-1 POH Processor block is using to locate the SPE within the incoming STS-1/STS-3 data stream.Note These register bits comprise the Lower Byte value of the Pointer Value. TABLE 154: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE VALUE REGISTER (ADDRESS = 0X02B9) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Defect_C2_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Defect_C2_Byte_Value[7:0] These READ/WRITE bit-fields are used to configure the Receive STS-1 POH Processor block to automatically force the transmission of the DS1/E1 AIS pattern (in the Egress Direction of all 28 channels) anytime it accepts a C2 byte value matching that written into this register. NOTE: The chip will only automatically transmit the DS1/E1 AIS Pattern if BIT 1 (Defect C2 Byte Downstream AIS Enable), within the Receive STS-1 Path - Receive Auto AIS - C2 Byte Control Register is set to 1. TABLE 155: RECEIVE STS-1 PATH - RECEIVE AUTO AIS - C2 BYTE CONTROL REGISTER (ADDRESS = 0X02BA) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Defect C2 Byte Downstream AIS Enable Unused R/O R/O R/O R/O R/O R/O R/W R/O 0 0 0 0 0 0 0 0 BIT [7:2] - Unused BIT 1] - Defect C2 Byte Downstream AIS Enable BIT 0 - Unused 125 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 156: RECEIVE STS-1 PATH - AUTO AIS CONTROL REGISTER (ADDRESS LOCATION= 0X02BB) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Transmit AIS-P (Downstream) Upon C2 Byte Unstable Transmit AIS-P (Downstream) Upon UNEQ-P Transmit AIS-P (Downstream) Upon PLM-P Transmit AIS-P (Downstream) Upon Path Trace Message Unstable Transmit AIS-P (Downstream) upon TIM-P Transmit AIS-P (Downstream) upon LOP-P Transmit AIS-P (Downstream) Enable R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Unused BIT 6 - Transmit Path AIS (Downstream) upon Declaration of the Unstable C2 Byte Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), anytime (and for the duration that) it declares the Unstable C2 Byte Defect condition within the incoming STS-1/STS-3 data-stream. ` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the Unstable C2 Byte defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the Unstable C2 Byte defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 5 - Transmit Path AIS (Downstream) upon Declaration of the UNEQ-P (Path - Unequipped) Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), anytime (and for the duration that) it declares the UNEQ-P defect condition. ` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the UNEQ-P defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the UNEQ-P defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 4 - Transmit Path AIS (Downstream) upon Declaration of the PLM-P (Path - Payload Label Mismatch) Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), anytime (and for the duration that) it declares the PLM-P defect condition. ` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the PLM-P defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the PLM-P defect condition.Note NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 3 - Transmit Path AIS (Downstream) upon declaration of the Path Trace Message Unstable Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), anytime (and for the duration that) it declares the Path Trace Message Unstable defect condition within 126 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS the incoming STS-1/STS-3 data-stream. ` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the Path Trace Message Unstable defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic) whenever it declares the Path Trace Message Unstable defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 2 - Transmit Path AIS (Downstream) upon declaration of the TIM-P (Path Trace Message Identification Mismatch) defect condition This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit a Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), anytime (and for the duration that) it declares the TIM-P defect condition within the incoming STS1/STS-3 data-stream. ` 0 - Does not configure the Receive STS-1 POH Processor block to transmit the AIS-P indicator (via the downstream traffic) whenever it declares the TIM-P defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to transmit the AIS-P indicator (via the downstream traffic) whenever it declares the TIM-P defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 1 - Transmit Path AIS (Downstream) upon Detection of Loss of Pointer (LOP-P) Defect Condition This READ/WRITE bit-field is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), anytime (and for the duration that) it declares the LOP-P defect condition within the incoming STS1/STS-3 data-stream. ` 0 - Does not configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic, towards the corresponding Transmit SONET POH Processor block) whenever it declares the LOPP defect condition. ` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic, towards the corresponding Transmit SONET POH Processor block) whenever it declares the LOPP defect condition. NOTE: The user must also set BIT 0 (Transmit AIS-P Enable) to 1 to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator, in response to this defect condition. BIT 0 - Automatic Transmission of AIS-P Enable This READ/WRITE bit-field serves two purposes. • It is used to configure the Receive STS-1 POH Processor block to automatically transmit the Path AIS indicator, via the down-stream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks), upon detection of an UNEQ-P, PLM-P, LOP-P or LOS conditions. • It also is used to configure the Receive STS-1 POH Processor block to automatically transmit a Path (AIS-P) Indicator via the downstream traffic (e.g., towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks) anytime it detects an AIS-P condition in the incoming STS-1/STS-3 data-stream. ` 0 - Configures the Receive STS-1 POH Processor block to NOT automatically transmit the AIS-P indicator (via the downstream traffic, towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks) whenever it declares any of the above-mentioned defect conditions. ` 1 - Configures the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator (via the downstream traffic, towards each of the 28 Egress Direction Transmit DS1/E1 Framer blocks) whenever it declares any of the above-mentioned defect condition. NOTE: The user must also set the corresponding bit-fields (within this register) to 1 in order to configure the Receive STS-1 POH Processor block to automatically transmit the AIS-P indicator upon detection of a given alarm/defect condition. 127 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 157: RECEIVE STS-1 PATH - SONET RECEIVE AUTO ALARM REGISTER - BYTE 0 (ADDRESS LOCATION= 0X02C3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Transmit AIS (via Downstream T1/E1s) upon LOP-P Transmit AIS (via Downstream T1/E1s) uponPLM-P Unused Transmit AIS (via Downstream T1/E1s) upon UNEQP Transmit AIS (via Downstream T1/E1s) upon TIM-P Transmit AIS (via Downstream T1/E1s) upon AIS-P Unused R/W R/W R/W R/O R/W R/W R/W R/O 0 0 0 0 0 0 0 0 BIT 7 - Unused BIT 6 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the LOP-P defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the LOP-P defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1 POH Processor block declares the LOP-P defect. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the LOP-P defect. BIT 5 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the PLM-P defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the PLM-P defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1 POH Processor block declares the PLM-P defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the PLM-P defect condition. BIT 4 - Unused BIT 3 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the UNEQ-P defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the UNEQ-P defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1 POH Processor block declares the UNEQ-P defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the UNEQ-P defect condition. BIT 2 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon declaration of the TIM-P defect condition This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the TIM-P defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime the Receive STS-1 POH Processor block declares 128 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS the TIM-P defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the TIM-P defect condition. BIT 1 - Transmit DS1/E1 AIS (via Downstream T1/E1s) upon AIS-P This READ/WRITE bit-field is used to configure each of the 28 Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the AIS-P defect condition. ` 0 - Does not configure all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS Indicator via the downstream DS1/E1 signal, anytime the Receive STS-1 POH Processor block declares the AIS-P defect condition. ` 1 - Configures all 28 of the Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the AIS-P Indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive STS-1 POH Processor block declares the AIS-P defect condition. BIT 0 - Unused TABLE 158: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS = 0X02C4) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Negative Pointer Adjustment Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Negative Pointer Adjustment Count - MSB These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Negative Pointer Adjustment Count Register - Byte 0 present a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that the Receive STS-1 POH Processor block has detected since the last read of these registers. NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression. TABLE 159: RECEIVE STS-1 PATH - RECEIVE NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS = 0X02C5) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Negative Pointer Adjustment Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Negative Pointer Adjustment Count - LSB These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Negative Pointer Adjustment Count Register - Byte 1 present a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that the Receive STS-1 POH Processor block has detected since the last read of these registers. NOTE: This register contains the LSB (Least Significant Bits) of this 16-bit expression. 129 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 160: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS = 0X02C6) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Positive Pointer Adjustment Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Positive Pointer Adjustment Count - MSB These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Positive Pointer Adjustment Count Register - Byte 0 present a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that the Receive STS-1 POH Processor block has detected since the last read of these registers. NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression. TABLE 161: RECEIVE STS-1 PATH - RECEIVE POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS = 0X02C7) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Positive Pointer Adjustment Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Positive Pointer Adjustment Count - LSB These RESET-upon-READ bits, along with that in Receive STS-1 Path - Receive Positive Pointer Adjustment Count Register - Byte 1 present a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that the Receive STS-1 POH Processor block has detected since the last read of these registers. NOTE: This register contains the LSB (Least Significant Bits) of this 16-bit expression. TABLE 162: RECEIVE STS-1 PATH - RECEIVE J1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 J1_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - J1 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the J1 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new J1 byte value. TABLE 163: RECEIVE STS-1 PATH - RECEIVE B3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02D7) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B3_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - B3 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the B3 byte, within the most recently received STS-1/STS-3 frame. 130 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new B3 byte value. TABLE 164: RECEIVE STS-1 PATH - RECEIVE C2 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DB) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 C2_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - C2 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the C2 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new C2 byte value. TABLE 165: RECEIVE STS-1 PATH - RECEIVE G1 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02DF) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 G1_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - G1 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the G1 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new G1 byte value. TABLE 166: RECEIVE STS-1 PATH - RECEIVE F2 BYTE CAPTURE REGISTER (ADDRESS LOCATION=0X02E3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 F2_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - F2 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the F2 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new F2 byte value. TABLE 167: RECEIVE STS-1 PATH - RECEIVE H4 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02E7) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 H4_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - H4 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the H4 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new H4 byte value. 131 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 168: RECEIVE STS-1 PATH - RECEIVE Z3 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EB) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Z3_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Z3 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the Z3 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new Z3 byte value. TABLE 169: RECEIVE STS-1 PATH - RECEIVE Z4 (K3) BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02EF) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Z4(K3)_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Z4 (K3) Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the Z4 (K3) byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new Z4 (K3) byte value. TABLE 170: RECEIVE STS-1 PATH - RECEIVE Z5 BYTE CAPTURE REGISTER (ADDRESS LOCATION= 0X02F3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Z5_Byte_Captured_Value[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Z5 Byte Captured Value[7:0] These READ-ONLY bit-fields contain the value of the Z5 byte, within the most recently received STS-1/STS-3 frame. This particular value is stored in this register for one STS-1/STS-3 frame period. During the next STS-1/STS-3 frame period, this value will be overridden with a new Z5 byte value. 132 PRELIMINARY REV. P1.0.6 2.5 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS RECEIVE TUG-3 MAPPER/VC-4 APPLICATIONS ONLY) POH PROCESSOR BLOCK REGISTERS (SDH/TUG-3 The register map for the Receive TU-3 Mapper/VC-4 POH Processor block is presented and discussed in detail within the "SDH Version of the Register Map". In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328 device, with the Receive TUG-3 Maper/VC-4 POH Processor block "highlighted" is presented below in Figure 5. FIGURE 5. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE RECEIVE TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK "HIGHLIGHTED" Transmit Transmit STM-1 STM-1 SOH SOH Processor Processor Block Block Transmit Transmit TUG-3 TUG-3 Mapper/ Mapper/ VC-4 VC-4POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Transmit Transmit VC-3 VC-3POH POH Processor Processor Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From TU Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block STS-1/ STS-1/ STM-0 STM-0 Telecom Telecom Bus Bus Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block Receive Receive TUG-3 TUG-3 Mapper/ Mapper/ VC-4 VC-4 POH POH Processor Processor Block Block Receive Receive VC-3 VC-3POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To TU Channels 1 - 27 Receive Receive STM-1 STM-1 SOH SOH Processor Processor Block Block From DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 For detailed on the "Receive TUG-3 Mapper/VC-4 POH Processor Block" Registers, please see the "XRT86SH328 28-Channel DS1/E1 Framer/LIU with DS3 MUX and TU-Mapper IC - Register Map & Description - SDH Applications" 2.6 TRANSMIT STS-1/STS-3 TOH PROCESSOR BLOCK REGISTERS The register map for the Transmit STS-1/STS-3 TOH Processor block is presented in the Table below. Additionally, a detailed description of each of the Transmit STS-1/STS-3 TOH Processor Block registers is presented below. In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328, with the Transmit STS-1/STS-3 TOH Processor Block highlighted is presented below in Figure 6. 133 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 6. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS1/STS-3 TOH PROCESSOR BLOCK HIGHLIGHTED Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 TABLE 171: TRANSMIT STS-1/STS-3 TRANSPORT- TRANSMIT CONTROL REGISTER - BYTE 3 (ADDRESS LOCATION = 0X0700) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 Control_Pointer[3:0] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT [3:0] - Control_Pointer[3:0] 134 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 172: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION = 0X0701) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Auto Transmit AIS-L Enable Section DCC Relocate Line DCC Relocate R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:3] - Unused BIT 2 - Auto Transmit AIS-L Enable BIT 1 - Section DCC Relocate BIT 0 - Line DCC Relocate TABLE 173: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X0702) BIT 7 BIT 6 Reserved BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 E2 InsertMethod E1 Insert Method F1 Insert Method S1 Insert Method K1K2 Insert Method M0M1 Insert Method[1] R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Unused BIT 5 - E2 Byte Insert Method This READ/WRITE bit-field is used to specify the source of the contents of the E2 byte, within the transmit output STS1/STS-3 or STS-3 data stream. 0 - E2 Byte is obtained from TxTOH Serial Input Port.] 1 - E2 Byte is obtained from the contents within the Transmit Transport - E2 Byte Value register (Address Location = 0x0747). This selection provides the user with software control over the value of the outbound E2 byte. BIT 4 - E1 Byte Insert Method This READ/WRITE bit-field is used to specify the source of the contents of the E1 byte, within the transmit output STS1 or STS-3 data stream. 0 - E1 Byte is obtained from TxTOH Serial Input Port. 1 - E1 Byte is obtained from the contents within the Transmit Transport - E1 Byte Value register (Address Location= 0x0743). This selection provides the user with software control over the value of the outbound E1 byte. BIT 3 - F1 Byte Insert Method This READ/WRITE bit-field is used to specify the source of the contents of the F1 byte, within the transmit output STS1 or STS-3 data stream. 0 - F1 Byte is obtained from TxTOH Serial Input Port. 1 - F1 Byte is obtained from the contents within the Transmit Transport - F1 Byte Value register (Address Location= 0x073F). This selection provides the user with software control over the value of the outbound F1 byte. BIT 2 - S1 Byte Insert Method This READ/WRITE bit-field is used to specify the source of the contents of the S1 byte, within the transmit output STS1 or STS-3 data stream. 0 - S1 Byte is obtained from TxTOH Serial Input Port. 1 - S1 Byte is obtained from the contents within the Transmit Transport - S1 Byte Value register (Address Location= 0x073B). This selection provides the user with software control over the value of the outbound S1 byte. 135 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT 1 - K1K2 Byte Insert Method This READ/WRITE bit-field is used to specify the source of the contents of the K1 and K2 bytes, within the transmit output STS-1 or STS-3 data stream. 0 - K1 and K2 Bytes are obtained from TxTOH Serial Input Port. 1 - K1 and K2 Bytes are obtained from the contents within the Transmit Transport - K1K2 Byte Value register - Byte 1 (Address Location= 0x072E) and the Transmit Transport - K1K2 Byte Value register - Byte 2 (Address Location= 0x072F). This selection provides the user with software control over the value of the outbound K1 and K2 bytes. BIT 0 - M0M1 Insert Method This READ/WRITE bit-field, along with M0M1 Insert Method[0] (located in the Transmit Transport - SONET Control Register - Byte 0) are used to specify the source of the contents of the M0/M1 byte, within the transmit output STS-1 or STS-3 data stream. The relationship between these two bit-fields and the corresponding source of the M0/M1 byte is presented below. Source of M)/M1 Byte M0M1 INSERT METHOD[1:0] SOURCE OF M0/M1 BYTE 0 0 From the Receive STS-1/STS-3 TOH Processor block (B2 byte (or BIP-24) Error Count) 0 1 Obtained from the contents of the Transmit STS-1/STS-3 Transport - M0/M1 Byte Value register (Address Location= 0x0737). 1 0 M0/M1 byte is obtained from the TxTOH Serial Input Port. 1 1 From the Receiver STS-1/STS-3 TOH Processor block (B2 byte (or BIP-24) Error Count). TABLE 174: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0703) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M0M1 Insert Method[0] Unused RDI-L Force AIS-L Force LOSForce Scramble Enable B2 Error Insert A1A2 Error Insert R/W R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - M0M1 Insert Method This READ/WRITE bit-field, along with M0M1 Byte Insert Method[1] (located in the Transmit STS-1/STS-3 Transport SONET Control Register - Byte 1) are used to specify the source of the contents of the M0/M1 byte, within the transmit output STS-1 or STS-3 data stream. The relationship between these two bit-fields and the corresponding source of the M0/M1 byte is presented below. Source of M0/M1 Byte M0M1 BYTE INSERT METHOD[1:0] SOURCE OF M0/M1 BYTE 0 0 From the Receive STS-1/STS-3 TOH Processor block (B2 Byte Error Count) 0 1 Obtained from the contents of the Transmit STS-1/STS-3 Transport - M0/M1 Byte Value register (Address Location= 0x0737). 1 0 M0/M1 byte is obtained from the TxTOH Serial Input Port. 1 1 From the Receive STS-1/STS-3 TOH Processor block (B2 Byte Error Count). 136 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT6 - Unused BIT 5 - Transmit Line - Remote Defect Indicator This READ/WRITE bit-field is used to (by software control) force the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the RDI-L indicator to the remote terminal equipment. ` 0 - Does not configure the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the RDI-L indicator. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the RDI-L indicator. In this case, the Transmit STS-1/STS-3 TOH Processor block will force bits 6, 7 and 8 (of the K2 byte) to the value 1, 1, 0. NOTE: This bit-field is ignored if the Transmit STS-1/STS-3 TOH Processor block is currently transmitting the Line AIS (AIS-L) indicator or LOS pattern. BIT 4 - Transmit Line - AIS Indicator This READ/WRITE bit-field is used to (by software control) force the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the AIS-L indicator to the remote terminal equipment. ` 0 - Does not configure the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the AIS-L indicator. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the AIS-L indicator. In this case, the Transmit STS-1/STS-3 TOH Processor block will force all bits (within the outbound STS-1 or STS-3 frame) with the exception of the Section Overhead Bytes to an All Ones pattern. NOTE: This bit-field is ignored if the Transmit STS-1/STS-3 TOH Processor block is transmitting the LOS pattern. BIT 3 - Transmit LOS Pattern This READ/WRITE bit-field is used to (by software control) force the Transmit STS-1/STS-3 TOH Processor block to transmit the LOS (Loss of Signal) pattern to the remote terminal equipment. ` 0 - Does not configure the Transmit STS-1/STS-3 TOH Processor block to generate and transmit the LOS pattern. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to transmit the LOS pattern. In this case, the Transmit STS-1/STS-3 TOH Processor block will force all bytes (within the outbound SONET frame) to an All Zeros pattern. BIT 2 - Scramble Enable This READ/WRITE bit-field is used to either enable or disable the Scrambler, within the Transmit STS-1/STS-3 TOH Processor block circuitry. ` 0 - Disables the Scrambler. ` 1 - Enables the Scrambler. BIT 1 - Transmit B2 Byte Error Insert Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to insert errors into the outbound B2 bytes, per the contents within the Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Mask Register. ` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT insert errors into the B2 bytes, within the outbound STS-1 or STS-3 signal. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to insert into the B2 bytes (per the contents within the Transmit B2 Byte Error Mask Register). BIT 0 - Transmit A1A2 Byte Error Insert Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to insert errors into the outbound A1 and A2 bytes, within the outbound STS-1 or STS-3 data-stream. ` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT insert errors into the A1 and A2 bytes, within the outbound STS-1 or STS-3 Data-stream. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to insert errors into the A1 and A2 bytes, within the outbound STS-1 or STS-3 Data-stream. 137 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 175: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A1 BYTE ERROR REGISTER (ADDRESS LOCATION = 0X0717) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Transmit Erred A1Byte Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:1] - Unused BIT 0 - Transmit Erred A1 Byte Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to transmit a continuous stream of STS-1 or STS-3 frames, in which the A1 byte is erred. ` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT transmit STS-1 or STS-3 frames with erred A1 bytes. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to transmit STS-1 or STS-3 frames with erred A1 bytes. TABLE 176: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT A2 BYTE ERROR REGISTER (ADDRESS LOCATION = 0X071F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Transmit Erred A2 Byte Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:1] - Unused BIT 0 - Transmit Erred A2 Byte Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to transmit a continuous stream of STS-1 or STS-3 frames, in which the A2 byte is erred. ` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT transmit STS-1 or STS-3 frames with erred A2 bytes. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to transmit STS-1 or STS-3 frames with erred A2 bytes. TABLE 177: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B1 BYTE ERROR MASK REGISTER (ADDRESS LOCATION = 0X0723) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 B1_Byte_Error_Mask[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0]B1 Byte Error Mask[7:0] These READ/WRITE bit-fields are used to insert bit errors into the B1 bytes, within the outbound STS-1 or STS-3 Data stream. The Transmit STS-1/STS-3 TOH Processor block will perform an XOR operation with the contents of the B1 byte, and this register. The results of this calculation will be inserted into the B1 byte position within the outbound STS1 or STS-3 Data stream. For each bit-field (within this register) that is set to 1, the corresponding bit, within the B1 byte will be in error. 138 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: For normal operation, the user should set this register to 0x00. TABLE 178: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BYTE ERROR MASK REGISTER (ADDRESS LOCATION = 0X0727) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused Transmit B2 Error Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:1] - Unused] BIT 0 - Transmit B2 Byte Error Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to perform the XOR operation with the contents of the Transmit STS-1/STS-3 Transport -Transmit B2 Bit Error Mask Register (Address Location = 0x072B) ` 0 - Disables the XOR operation. In this case, the Transmit STS-1/STS-3 TOH Processor block will NOT perform the XOR operation with the Transmit STS-1/STS-3 Transport - Transmit B2 Bit Error Mask Register. As a consequence, the Transmit STS-1/STS-3 TOH Processor block will transmit a continuous stream of STS-1s with no B2 byte errors. ` 1 - Enables the XOR operation. In this setting, the Transmit STS-1/STS-3 TOH Processor will perform the XOR operation of the value of the B2 byte (within the outbound STS-1 or STS-3 frame) with the contents within the Transmit STS-1/STS-3 Transport - Transmit B2 Bit Error Mask register. TABLE 179: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMIT B2 BIT ERROR MASK REGISTER (ADDRESS LOCATION= 0X072B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_B2_Error_Mask[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit B2 Error Mask-Byte These READ/WRITE bit-fields are used to insert B2 byte errors into the outbound STS-1 or STS-3 Data-stream, for diagnostic purposes. If BIT 0 (Transmit B2 Error Enable) within the Transmit STS-1/STS-3 Transport - Transmit B2 Byte Error Register (Address Location = 0xN927) is set to 1, then Transmit STS-1/STS-3 TOH Processor block will be configured to perform an XOR operation between the contents of this register, with the contents of the outbound B2 byte. The results of this calculation is written back into the B2 byte position, within the outbound STS-1 or STS-3 Data. Hence, for every bit (within this register) that is set to 1, the corresponding bit (within the outbound B2 byte) will be erred. NOTES: 1. 1. For normal (e.g., un-erred) operation, the user should ensure that this register is set to the value 0x00. 2. These register bits are ignored unless BIT 0 (Transmit B2 Error Enable), within the Transmit STS-1/STS3 Transport - Transmit B2 Byte Error Register has been set to 1. 139 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 180: TRANSMIT STS-1/STS-3 TRANSPORT - K2 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X072E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_K2_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit K2 Byte Value If the appropriate K1K2 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the K2 byte, within the outbound STS-1/STS-3 signal. NOTE: If BIT 1 (K1K2 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load the contents of this register into the K2 byte-field, within each outbound STS-1 or STS-3 frame. These register bits are ignored if BIT 1 (K1K2 Insert Method) is set to 0. TABLE 181: TRANSMIT STS-1/STS-3 TRANSPORT - K1 BYTE VALUE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X072F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_K1_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit K1 Byte Value If the appropriate K1K2 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the K1 byte, within the outbound STS-1/STS-3 signal. NOTE: If BIT 1 (K1K2 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load the contents of this register into the K1 byte-field, within each outbound STS-1 or STS-3 frame. These register bits are ignored if BIT 1 (K1K2 Insert Method) is set to 0. TABLE 182: TRANSMIT STS-1/STS-3 TRANSPORT - RDI-L CONTROL REGISTER (ADDRESS LOCATION= 0X0733) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 External RDI-L Enable Transmit RDI-L upon AIS Transmit RDI-L upon LOF Transmit RDI-L upon LOS R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT 3 - External Transmit Line Remote Defect Indicator (RDI-L) Enable This READ/WRITE bit-field is used to externally insert the value for bits 6, 7 and 8 (of the K2 byte) into the outbound STS-1 or STS-3 Data stream. If the user enables this feature, then the user can enable or disable the insertion of the RDI-L indicator, via the TxPOH_n input pin. 0 - Disables this feature. 1 - Enables this feature. BIT 2 - Transmit Line Remote Defect Indicator (RDI-L) upon Detection of AIS-L 140 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to automatically transmit a RDI-L indicator to the remote terminal anytime (and for the duration) that the Receive STS-1/STS-3 TOH Processor block is detecting a Line AIS (AIS-L) indicator. ` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT automatically transmit the RDI-L indicator, upon the Receive STS-1/STS-3 TOH Processor block detecting the AIS-L indicator. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to automatically transmit the RDI-L indicator, upon the Receive STS-1/STS-3 TOH Processor block detecting the AIS-L indicator. BIT 1 - Transmit Line Remote Defect Indicator (RDI-L) upon Detection of LOF This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to automatically transmit a RDI-L indicator to the remote terminal anytime (and for the duration) that the Receive STS-1/STS-3 TOH Processor block is declaring the LOF defect ` .0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT automatically transmit the RDI-L indicator, whenever the Receive STS-1/STS-3 TOH Processor block declares the LOF defect. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to automatically transmit the RDI-L indicator, whenever the Receive STS-1/STS-3 TOH Processor block declares the LOF defect. BIT 0 - Transmit Line Remote Defect Indicator (RDI-L) upon Detection of LOS This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 TOH Processor block to automatically transmit a RDI-L indicator to the remote terminal anytime (and for the duration) that the Receive STS-1/STS-3 TOH Processor block is declaring the LOS defect. ` 0 - Configures the Transmit STS-1/STS-3 TOH Processor block to NOT automatically transmit the RDI-L indicator, whenever the Receive STS-1/STS-3 TOH Processor block declares the LOS defect. ` 1 - Configures the Transmit STS-1/STS-3 TOH Processor block to automatically transmit the RDI-L indicator, whenever the Receive STS-1/STS-3 TOH Processor block declares the LOS defect. TABLE 183: TRANSMIT STS-1/STS-3 TRANSPORT - M0M1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0737) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_M0M1_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit M0M1 Byte Value If the appropriate M0M1 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the M0M1 byte, within the outbound STS-1/STS-3 signal. NOTE: If BIT 0 (M0M1 Insert Method - BIT 1) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register - Byte 1 (Address Location= 0x0702) and BIT7 (M0M1 Byte Insert Method - BIT 0) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register - Byte 0 (Address Location= 0x0703) are set to 0, 1, then the STS-1/STS-3 Transmit block will load the contents of this register into the M0M1 byte-field, within each outbound STS-1 or STS-3 frame. These register bits are ignored if the M0M1 Insert Method[1:0] bits are set to any value other than 0, 1. TABLE 184: TRANSMIT STS-1/STS-3 TRANSPORT - S1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_S1_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit S1 Byte Value If the appropriate S1 Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the S1 byte, within the outbound STS-1/STS-3 signal. If BIT 2 (S1 Insert Method) within the Transmit STS-1/STS-3 141 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Transport - SONET Transmit Control Register - Byte 1 (Address Location= 0x0702) is set to 1, then the STS-1/STS-3 Transmit block will load the contents of this register into the S1 byte-field, within each outbound STS-1 or STS-3 frame. NOTE: These register bits are ignored if BIT 2 (S1 Insert Method) is set to 0. TABLE 185: TRANSMIT STS-1/STS-3 TRANSPORT - F1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X073F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_F1_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit F1 Byte Value If the appropriate F1 Byte Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the F1 byte, within the outbound STS-1/STS-3 signal. NOTE: If BIT 3 (F1 Byte Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register - Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load the contents of this register into the F1 byte-field, within each outbound STS-1 or STS-3 frame. These register bits are ignored if BIT 3 (F1 Insert Method) is set to 0. TABLE 186: TRANSMIT STS-1/STS-3 TRANSPORT - E1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0743) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_E1_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit E1 Byte Value If the appropriate E1 Byte Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the E1 byte, within the outbound STS-1/STS-3 signal. Note NOTE: If BIT 4 (E1 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load the contents of this register into the E1 byte-field, within each outbound STS-1 or STS-3 frame. These register bits are ignored if BIT 4 (E1 Insert Method) is set to 0. TABLE 187: TRANSMIT STS-1/STS-3 TRANSPORT - E2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0747) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_E2_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit E2 Byte Value If the appropriate E2 Byte Insert Method is selected, then these READ/WRITE bit-fields will are used to specify the contents of the E2 byte, within the outbound STS-1/STS-3 signal. NOTE: If BIT 5 (E2 Insert Method) within the Transmit STS-1/STS-3 Transport - SONET Transmit Control Register Byte 1 (Address Location= 0x0702) is set to 1, then the Transmit STS-1/STS-3 TOH Processor block will load the contents of this register into the E2 byte-field, within each outbound STS-1 or STS-3 frame. These register bits are ignored if BIT 5 (E2 Insert Method) is set to 0. 142 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 188: TRANSMIT STS-1/STS-3 TRANSPORT - J0 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X074B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_J0_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit J0 Byte Value These READ/WRITE bits are used to specify the value of the J0 byte, that will be transmitted via the Transport Overhead, within the very next STS-1 or STS-3 frame. This register is only valid if the Transmit STS-1/STS-3 TOH Processor block is configured to read out the contents from this register and insert it into the J0 byte-field within each outbound STS-1 or STS-3 frame. The user accomplishes this by setting Bits 1 and 0 (J0_TYPE), within the Transmit STS-1/STS-3 Transport - J0 Byte Control Register (Address Location= 0x074F) to 1, 0. TABLE 189: TRANSMIT STS-1/STS-3 TRANSPORT - TRANSMITTER J0 BYTE CONTROL REGISTER (ADDRESS LOCATION= 0X074F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 Message Length[1:0] BIT 0 J0_TYPE[1:0] R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT [3:2] - Message Length[1:0] These two READ/WRITE bit-fields are used to specify the length of the message that is to be repetitively transmitted via the J0 byte as shown in the table below. J Message Length MSG_LENGTH[1:0] CORRESPONDING MESSAGE LENGTH(BYTES) 00 1 Byte 01 16 Bytes 10 or 11 64 Bytes BIT [1:0] - Transmit J0 Source[1:0] These two READ/WRITE bit-fields are used to specify the source of the message that will be transported via the J0 byte/message, within the outbound STS-1 or STS-3 Data-stream, as shown in the table below Source of J0 Byte Message 0_TYPE[1:0] CORRESPONDING SOURCE OF J0 BYTE/MESSAGE. 00 Automatically set the J0 Byte, in each outbound STS-1 or STS-3 frame to 0x01. 01 The Transmit Section TraceMessage BufferThe Transmit STS-1/STS-3 Section Trace Buffer Memory is located at Address locations 0x0900 through 0x093F. 143 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Source of J0 Byte Message 0_TYPE[1:0] CORRESPONDING SOURCE OF J0 BYTE/MESSAGE. 10 From the Transmit J0 Byte Value[7:0] Register. In this setting, the Transmit STS-1/STS-3 TOH Processor block will read out the contents of the Transmit J0 Value[7:0] Register (Address Location= 0x074B), and will insert this value into the J0 byte of each outbound STS1 or STS-3 frame. 11 From the TxPOH_n Input pin. 144 PRELIMINARY REV. P1.0.6 2.7 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TRANSMIT STS-1/STS-3 POH PROCESSOR BLOCK REGISTERS The register map for the Transmit STS-1/STS-3 POH Processor block is presented in the Table below. Additionally, a detailed description of each of the Transmit STS-1/STS-3 POH Processor block registers is presented below. In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328, with the Transmit STS-1/STS-3 POH Processor block highlighted is presented below in Figure 7. FIGURE 7. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE TRANSMIT STS1/STS-3 POH PROCESSOR BLOCK HIGHLIGHTED Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 TABLE 190: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION = 0X0781) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Payload_Type[1:0] R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:2] - Unused BIT [1:0] - Payload_Type[1:0] 145 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 191: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0782) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Z5 InsertionType Z4 InsertionType Z3 InsertionType H4 Insertion Type R/W R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT 3 - Z5 Insertion Type This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the Transmit STS-1/STS-3 Path - Transmit Z5 Value Register or the TPOH input pin as the source for the Z5 byte, in the outbound STS-1/STS-3 SPE. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit Z5 Value Register (Address Location= 0x07B3). ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the Z5 byte, in the outbound STS-1/STS-3 SPE. BIT 2 - Z4 Insertion Type This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the Transmit STS-1/STS-3 Path - Transmit Z4 Value Register or the TPOH input pin as the source for the Z4 byte, in the outbound STS-1/STS-3 SPE. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit Z4 Value Register (Address Location= 0x07AF). ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the Z4 byte, in the outbound STS-1/STS-3 SPE. BIT 1 - Z3 Insertion Type This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the Transmit STS-1/STS-3 Path - Transmit Z3 Value Register or the TPOH input pin as the source for the Z3 byte, in the outbound STS-1/STS-3 SPE. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit Z3 Value Register (Address Location = 0x07AB). ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the Z3 byte, in the outbound STS-1/STS-3 SPE. BIT 0 - H4 Insertion Type This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the Transmit STS-1/STS-3 Path - Transmit H4 Value Register or the TPOH input pin as the source for the H4 byte, in the outbound STS-1/STS-3 SPE. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit H4 Value Register (Address Location= 0x07A7). ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the H4 byte, in the outbound STS-1/STS-3 SPE. 146 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 192: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X0783) BIT 7 BIT 6 F2 Insertion Type BIT 5 REI-P Insertion Type[1:0] BIT 4 BIT 3 RDI-P Insertion Type[1:0] BIT 2 BIT 1 BIT 0 C2 Byte Insertion Type C2 Byte Auto Insert Mode Enable Transmit AIS-P Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - F2 Insertion Type This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the Transmit STS-1/STS-3 Path - Transmit F2 Value Register or the TPOH input pin as the source for the F2 byte, in the outbound STS-1/STS-3 SPE. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit F2 Value Register (Address Location= 0x07A3). ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the F2 byte, in the outbound STS-1/STS-3 SPE. BIT [6:5] - REI-P Insertion Type[1:0] These two READ/WRITE bit-fields are used to configure the Transmit STS-1/STS-3 POH Processor block to use one of the three following sources for the REI-P bit-fields (e.g., bits 1 through 4, within the G1 byte of the outbound STS1/STS-3 SPE). • From the corresponding Receive STS-1/STS-3 POH Processor block (e g., when it detects B3 bytes in its incoming SPE data). • From the Transmit G1 Byte Value Register (Address Location= 0x079F). • From the TPOH input pin. ` 00/11 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 1 through 4 (in the G1 byte of the outbound SPE) based upon receive conditions as detected by the corresponding Receive STS-1/STS-3 POH Processor block. ` 01 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 1 through 4 (in the G1 byte of the outbound SPE) based upon the contents within the Transmit G1 Byte Value register (Address Location= 0x079F). ` 10 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input pin as the source of Bits 1 through 4 (in the G1 byte of the outbound SPE). BIT [4:3] - RDI-P Insertion Type[1:0] These two READ/WRITE bit-fields are used to configure the Transmit STS-1/STS-3 POH Processor block to use one of the three following sources for the RDI-P bit-fields (e.g., bits 5 through 7, within the G1 byte of the outbound STS1/STS-3 SPE). • From the Receive STS-1/STS-3 POH Processor block (e g., when it detects various alarm conditions within its incoming SPE data). • From the Transmit G1 Byte Value Register (Address Location = 0x079F). • From the TPOH input pin. ` 00/11 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 5 through 7 (in the G1 byte of the outbound SPE) based upon receive conditions as detected by the Receive STS-1/STS-3 POH Processor block. ` 01 - Configures the Transmit STS-1/STS-3 POH Processor block to set Bits 5 through 7 (in the G1 byte of the outbound SPE) based upon the contents within the Transmit G1 Byte Value register. ` 10 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input pin as the source of Bits 5 through 7 (in the G1 byte of the outbound SPE). BIT 2 - C2 Insertion Type This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to use either the Transmit STS-1/STS-3 Path - Transmit C2 Byte Value Register or the TPOH input pin as the source for the C2 byte, in 147 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 the outbound STS-1/STS-3 SPE. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to use the Transmit STS-1/STS-3 Path - Transmit C2 Value Register (Address Location= 0x079B). ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to use the TPOH input as the source for the C2 byte, in the outbound STS-1/STS-3 SPE. BIT 1 - Auto-Insert PDI-P Indicator Enable This READ/WRITE bit-field are used to configure the Transmit STS-1/STS-3 POH Processor block to automatically insert the PDI-P (Path - Payload Defect Indicator) whenever the AIS-P indicator is received from the Receive SONET POH Processor block. If this feature is enabled, then the Transmit STS-1/STS-3 POH Processor block will automatically set the C2 byte (within the outbound SPE) to 0xFC (to indicate a PDI-P condition) whenever it receives the AIS-P indicator, from the Receive SONET POH Processor block. BIT 0 - Transmit AIS-P Enable This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to (via software control) transmit an AIS-P indicator to the remote PTE.If this feature is enabled, then the Transmit STS-1/STS-3 POH Processor block will automatically set the H1, H2, H3 and all the SPE bytes to an All Ones pattern, prior to routing this data to the Transmit STS-1/STS-3 TOH Processor block. ` 0 - Configures the Transmit STS-1/STS-3 POH Processor block to NOT transmit the AIS-P indicator to the remote PTE. ` 1 - Configures the Transmit STS-1/STS-3 POH Processor block to transmit the AIS-P indicator to the remote PTE. TABLE 193: TRANSMIT STS-1/STS-3 PATH - TRANSMITTER J1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X0793) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_J1_Byte[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit J1 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the J1 byte, within each outbound STS-1/STS-3 SPE. If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the J1 byte, then it will automatically write the contents of this register into the J1 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT 2 (C2 Insertion Type) within the Transmit STS-1/STS-3 Path - J1 Control Register register (Address Location= 0x0783). TABLE 194: TRANSMIT STS-1/STS-3 PATH - TRANSMIT B3 BYTE ERROR MASK REGISTER (ADDRESS LOCATION= 0X0797) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_B3_Byte_Mask[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit B3 Byte Mask[7:0] This READ/WRITE bit-field is used to insert errors into the B3 byte, within the outbound STS-1/STS-3 SPE, prior to transmission to the Transmit STS-1/STS-3 TOH Processor block. The Transmit STS-1/STS-3 POH Processor block will perform an XOR operation with the contents of this register, and the B3 byte value. The results of this operation will be written back into the B3 byte of the outbound STS-1/STS-3 SPE. 148 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: If the user sets a particular bit-field, within this register, to 1, then that corresponding bit, within the outbound B3 byte will be in error. For normal operation, the user should set this register to 0x00. TABLE 195: TRANSMIT STS-1/STS-3 PATH - TRANSMIT C2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_C2_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit C2 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the C2 byte, within each outbound STS-1/STS-3 SPE. If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the C2 byte, then it will automatically write the contents of this register into the C2 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT 2 (C2 Byte Insertion Type) within the Transmit STS-1/STS3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0783). TABLE 196: TRANSMIT STS-1/STS-3 PATH - TRANSMIT G1 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X079F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_G1_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit G1 Byte Value: These READ/WRITE bit-fields are used to have software control over the contents of the RDI-P and REI-P bit-fields, within each G1 byte in the outbound STS-1/STS-3 SPE. NOTE: If the users sets REI-P_Insertion_Type[1:0] and RDI-P_Insertion_Type[1:0] bits to the value [0, 1], then contents of the REI-P and the RDI-P bit-fields (within each G1 byte of the outbound STS-1/STS-3 SPE) will be dictated by the contents of this register. The REI-P_Insertion_Type[1:0] and RDI-P_Insertion_Type[1:0] bitfields are located in the Transmit STS-1/STS-3 Path - SONET Control Register - Byte 0 Register (Address Location= 0x0783) TABLE 197: TRANSMIT STS-1/STS-3 PATH - TRANSMIT F2 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_F2_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit F2 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the F2 byte, within each outbound STS-1/STS-3 SPE. If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the F2 byte, then it will automatically write the contents of this register into the F2 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT7 (F2 Byte Insertion Type) within the Transmit STS-1/STS3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0783). 149 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 198: TRANSMIT STS-1/STS-3 PATH - TRANSMIT H4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07A7) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_H4_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit H4 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the H4 byte, within each outbound STS-1/STS-3 SPE. If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the H4 byte, then it will automatically write the contents of this register into the H4 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT 0 (H4 Insertion Type) within the Transmit STS-1/STS-3 Path - SONET Control Register - Byte 1 register (Address Location= 0x07A7). TABLE 199: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z3 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07AB) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Z3_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Z3 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the Z3 byte, within each outbound STS-1/STS-3 SPE.If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the Z3 byte, then it will automatically write the contents of this register into the Z3 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT 1 (Z3 Insertion Type) within the Transmit STS-1/STS-3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0782). TABLE 200: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z4 BYTE VALUE REGISTER (ADDRESS LOCATION= 0XN9AF) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Z4_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Z4 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the Z4 byte, within each outbound STS-1/STS-3 SPE. If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the Z4 byte, then it will automatically write the contents of this register into the Z4 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT 2 (Z4 Insertion Type) within the Transmit STS-1/STS-3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0782). 150 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 201: TRANSMIT STS-1/STS-3 PATH - TRANSMIT Z5 BYTE VALUE REGISTER (ADDRESS LOCATION= 0X07B3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Z5_Byte_Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Z5 Byte Value These READ/WRITE bit-fields are used to have software control over the value of the Z5 byte, within each outbound STS-1/STS-3 SPE. If the user configures the Transmit STS-1/STS-3 POH Processor block to this register as the source of the Z5 byte, then it will automatically write the contents of this register into the Z5 byte location, within each outbound STS-1/STS-3 SPE. This feature is enabled whenever the user writes a 0 into BIT 3 (Z5 Insertion Type) within the Transmit STS-1/STS-3 Path - SONET Control Register - Byte 0 register (Address Location= 0x0782). TABLE 202: TRANSMIT STS-1/STS-3 PATH - TRANSMIT PATH CONTROL REGISTER (ADDRESS LOCATION= 0X07B7) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Pointer Force Check Stuff Insert Negative Stuff InsertPositive Stuff InsertContinuous NDF Events InsertSingle NDF Event R/O R/O R/W R/W W W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Unused BITt 5 - Pointer Force This READ/WRITE bit-field is used to load the values contained within the Transmit STS-1/STS-3 POH Arbitrary H1 Pointer and Transmit STS-1/STS-3 POH Arbitrary H2 Pointer registers (Address Location= 0x07BF and 0x07C3) into the H1 and H2 bytes (within the outbound STS-1 or STS-3 Data stream). The actual location of the SPE will NOT be adjusted, per the value of H1 and H2 bytes. Hence, this feature should cause the remote terminal to declare an Invalid Pointer condition. ` 0 - Configures the Transmit STS-1/STS-3 POH and TOH Processors to transmit STS-1 or STS-3 Data with normal and correct H1 and H2 bytes. ` 1 - Configures the Transmit STS-1/STS-3 POH and TOH Processor blocks to overwrite the values of the H1 and H2 bytes (in the outbound STS-1 or STS-3 Data-stream) with the values in the Transmit STS-1/STS-3 POH Arbitrary H1 and H2 Pointer registers. BITt 4 - Check Stuff Monitoring This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to only execute a Positive, Negative or NDF event (via the Insert Positive Stuff, Insert Negative Stuff, Insert Continuous or Single NDF options, via software command) if no pointer adjustment (NDF or otherwise) has occurred during the last 3 STS-1/STS-3 frame periods. ` 0 - Disables this feature.In this mode, the Transmit STS-1/STS-3 POH and TOH Processor block will execute a software-commanded pointer adjustment event, independent of whether a pointer adjustment event has occurred in the last 3 STS-1/STS-3 frame periods. ` 1 - Enables this feature.In this mode, the Transmit STS-1/STS-3 POH and TOH Processor block will ONLY execute a software-commanded pointer adjustment event, if no pointer adjustment event has occurred during the last 3 STS1/STS-3 frame periods. BITt 3 - Insert Negative Stuf This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to insert a negative-stuff into the outbound STS-1 or STS-3 Data stream. This command, in-turn will cause a Pointer 151 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Decrementing event at the remote terminal. ` Writing a 0 to 1 transition into this bit-field causes the following to happen. • A negative-stuff will occur (e.g., a single payload byte will be inserted into the H3 byte position within the outbound STS-1 or STS-3 Data stream). • The D bits, within the H1 and H2 bytes will be inverted (to denote a Decrementing Pointer Adjustment event). • The contents of the H1 and H2 bytes will be decremented by 1, and will be used as the new pointer from this point on. NOTE: Once the user writes a 1 into this bit-field, the XRT86SH328 will automatically clear this bit-field. Hence, there is no need to subsequently reset this bit-field to 0. BITt 2 - Insert Positive Stuff This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to insert a positive-stuff into the outbound STS-1 or STS-3 Data stream. This command, in-turn will cause a Pointer Incrementing event at the remote terminal. ` Writing a 0 to 1 transition into this bit-field causes the following to happen. • A positive-stuff will occur (e.g., a single stuff-byte will be inserted into the STS-1 or STS-3 Data-stream, immediately after the H3 byte position within the outbound STS-1 or STS-3 Data stream). • The I bits, within the H1 and H2 bytes will be inverted (to denote a Incrementing Pointer Adjustment event). • The contents of the H1 and H2 bytes will be incremented by 1, and will be used as the new pointer from this point on.Note NOTE: Once the user writes a 1 into this bit-field, the XRT86SH328 will automatically clear this bit-field. Hence, there is no need to subsequently reset this bit-field to 0. BITt 1 - Insert Continuous NDF Events This READ/WRITE bit-field is used configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to continuously insert a New Data Flag (NDF) pointer adjustment into the outbound STS-1 or STS-3 Data stream. As the Transmit STS-1/STS-3 POH and TOH Processor blocks insert the NDF event into the STS-1 or STS-3 Data stream, it will proceed to load in the contents of the Transmit STS-1/STS-3 POH Arbitrary H1 Pointer and Transmit STS1/STS-3 POH Arbitrary H2 Pointer registers into the H1 and H2 bytes (within the outbound STS-1 or STS-3 Data stream). ` 0 - Configures the Transmit STS-1/STS-3 TOH and POH Processor blocks to not continuously insert NDF events into the outbound STS-1 or STS-3 Data stream. ` 1- Configures the Transmit STS-1/STS-3 TOH and POH Processor blocks to continuously insert NDF events into the outbound STS-1 or STS-3 Data stream. BITt 0 - Insert Single NDF Event This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH and TOH Processor blocks to insert a New Data Flag (NDF) pointer adjustment into the outbound STS-1 or STS-3 Data stream. ` Writing a 0 to 1 transition into this bit-field causes the following to happen • The N bits, within the H1 byte will set to the value 1001 • The ten pointer-value bits (within the H1 and H2 bytes) will be set to new pointer value per the contents within the Transmit STS-1/STS-3 POH - Arbitrary H1 Pointer and Transmit STS-1/STS-3 POH Arbitrary H2 Pointer registers (Address Location= 0x07BF and 0xN9C3). NOTE: Afterwards, the N bits will resume their normal value of 0110 and this new pointer value will be used as the new pointer from this point on. Once the user writes a 1 into this bit-field, the XRT86SH328 will automatically clear this bit-field. Hence, there is no need to subsequently reset this bit-field to 0. 152 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 203: TRANSMIT STS-1/STS-3 PATH - SONET PATH J1 CONTROL REGISTER (ADDRESS LOCATION= 0X07BB) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Insertion_Method[1:0] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:2] - Unused BIT [1:0] - J1 Byte Insertion_Method[1:0] These READ/WRITE bit-fields are used to specify the method that the user will use to insert the J1 byte into the outbound STS-1/STS-3 SPE. The relationship between the contents of these bit-fields and the corresponding J1 Byte Insertion Method is presented below. Insertion Method J1 BYTE INSERTION METHOD[1:0] RESULTING INSERTION METHOD 00 Insert the value 0x00 01 Not Valid 10 Insert from the Transmit SONET Path - Transmit J1 Byte Value Register (Address Location= 0x0793) 11 Insert via the TxPOH_n input port TABLE 204: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H1 POINTER REGISTER (ADDRESS LOCATION= 0X07BF) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 NDF Bits BIT 2 SS Bits BIT 1 BIT 0 H1 Pointer Value R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - NDF (New Data Flag) Bits These READ/WRITE bit-fields are used provide the value that will be loaded into the NDF bit-field (of the H1 byte), whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path Control Register (Address Location= 0x07B7). BIT [3:2] - SS Bits These READ/WRITE bit-fields is used to provide the value that will be loaded into the SS bit-fields (of the H1 byte) whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path Control Register (Address Location= 0x07B7). The SS bits have no functional value, within the H1 byte. BIT [1:0] - H1 Pointer Value[1:0] These two READ/WRITE bit-fields, along with the constants of the Transmit STS-1/STS-3 Path - Transmit Arbitrary H2 Pointer Register (Address Location= 0x07C3) are used to provide the contents of the Pointer Word. These two READ/WRITE bit-fields are used to define the value of the two most significant bits within the Pointer word. Whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path Control Register (Address Location= 0x07B7), the values of these two bits will be loaded into the two most significant 153 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 bits within the Pointer Word. TABLE 205: TRANSMIT STS-1/STS-3 PATH - TRANSMIT ARBITRARY H2 POINTER REGISTER (ADDRESS LOCATION= 0X07C3) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 H2 Pointer Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - H2 Pointer Value[1:0] These eight READ/WRITE bit-fields, along with the constants of bits 1 and 0 within the Transmit STS-1/STS-3 Path Transmit Arbitrary H1 Pointer Register (Address Location= 0x07C3) are used to provide the contents of the Pointer Word. These two READ/WRITE bit-fields are used to define the value of the eight least significant bits within the Pointer word. ` Whenever a 0 to 1 transition occurs in BIT 5 (Pointer Force) within the Transmit STS-1/STS-3 Path - Transmit Path Control Register (Address Location= 0x07B7), the values of these eight bits will be loaded into the H2 byte, within the outbound STS-1 or STS-3 Data stream. TABLE 206: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07C6) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Tx_Pointer_High[1:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 1 0 BIT [7:2] - Unused BIT [1:0] - Transmit Pointer Word - High[1:0] These two READ-ONLY bits, along with the contents of the Transmit STS-1/STS-3 Path - Transmit Current Pointer Byte Register - Byte 0 (Address Location= 0x07C7) reflect the current value of the pointer (or offset of SPE within the STS1/STS-3 frame). These two bits contain the two most significant bits within the 10-bit pointer word. TABLE 207: TRANSMIT STS-1/STS-3 PATH - TRANSMIT CURRENT POINTER BYTE REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07C7) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Tx_Pointer_Low[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 1 0 1 0 BIT [7:0] - Transmit Pointer Word - Low[7:0] These two READ-ONLY bits, along with the contents of the Transmit STS-1/STS-3 Path - Transmit Current Pointer Byte Register - Byte 1 (Address Location= 0x07C6) reflect the current value of the pointer (or offset of SPE within the STS1/STS-3 frame). These two bits contain the eight least significant bits within the 10-bit pointer word. 154 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 208: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 2 (ADDRESS LOCATION= 0X07C9) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 PLM-P RDI-P Code[2:0] BIT 0 Transmit RDI-P upon PLM-P R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT [3:1] - PLM-P (Path - Payload Mismatch) - RDI-P Code These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the corresponding Receive STS-1/STS-3 POH Processor block detects and declares a PLM-P condition. In order to enable this feature, the user must set BIT 0 (RDI-P upon PLM-P) within this register to 1. BIT 0 - Transmit RDI-P upon PLM-P This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically transmit the RDI-P Code (as configured in Bits 3 through 1 - within this register) whenever the corresponding Receive STS-1/STS-3 POH Processor block declares a PLM-P condition. ` 0 - Disables the automatic transmission of RDI-P upon detection of PLM-P. ` 1 - Enables the automatic transmission of RDI-P upon detection of PLM-P. TABLE 209: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07CA) BIT 7 BIT 6 BIT 5 TIM-P RDI-P Code[2:0] BIT 4 BIT 3 Transmit RDI-P upon TIM -P BIT 2 BIT 1 UNEQ-P RDI-P Code[2:0] BIT 0 Transmit RDI-P upon UNEQ-P R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:5] - TIM-P (Path - Trace Identification Message Mismatch) - RDI-P Code These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block will transmit within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the Receive STS-1/STS-3 POH Processor block detects and declares the TIM-P defect condition. To enable this feature, the user must set BIT 4 (Transmit RDI-P upon TIM-P) within this register to 1. BIT 4 - Transmit RDI-P upon TIM-P This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically transmit the RDI-P Code (as configured in Bits 7 through 5 - within this register) whenever the corresponding Receive STS-1/STS-3 POH Processor block declares the TIM-P defect condition. ` 0 - Disables the automatic transmission of RDI-P upon detection of TIM-P. ` 1 - Enables the automatic transmission of RDI-P upon detection of TIM-P. BIT [3:1] - UNEQ-P (Path - Unequipped) - RDI-P Code These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the Receive STS-1/STS-3 POH Processor block detects and declares the UNEQ-P defect condition. To enable this feature, the user must set BIT 0 (Transmit RDI-P upon UNEQ-P) within this register to 1. BIT 0 - Transmit RDI-P upon UNEQ-P 155 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically transmit the RDI-P Code (as configured in Bits 3 through 1 - within this register) whenever the corresponding Receive STS-1/STS-3 POH Processor block declares the UNEQ-P defect condition. ` 0 - Disables the automatic transmission of RDI-P upon detection of UNEQ-P. ` 1 - Enables the automatic transmission of RDI-P upon detection of UNEQ-P. TABLE 210: TRANSMIT STS-1/STS-3 PATH - RDI-P CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07CB) BIT 7 BIT 6 BIT 5 LOP-P RDI-P Code[2:0] BIT 4 BIT 3 Transmit RDI-P upon LOP-P BIT 2 BIT 1 AIS-P RDI-P Code[2:0] BIT 0 Transmit RDI-P upon AIS-P R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 156 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT [7:5] - LOP-P (Path - Loss of Pointer) - RDI-P Code These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the corresponding Receive STS-1/STS-3 POH Processor block detects and declares a LOP-P condition. To enable this feature, the user must set BIT 4 (RDI-P upon LOP-P) within this register to 1. BIT 4 - Transmit RDI-P upon LOP-P This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically transmit the RDI-P Code (as configured in Bits 7 through 5 - within this register) whenever the corresponding Receive STS-1/STS-3 POH Processor block declares a LOP-P condition ` 0 - Disables the automatic transmission of RDI-P upon detection of LOP-P. ` 1 - Enables the automatic transmission of RDI-P upon detection of LOP-P. BIT[3:1]AIS-P (Path - AIS) - RDI-P Code These three READ/WRITE bit-fields are used to specify the value that the Transmit STS-1/STS-3 POH Processor block will transmit, within the RDI-P bit-fields of the G1 byte (within the outbound STS-1/STS-3 SPE), whenever the corresponding Receive STS-1/STS-3 POH Processor block detects and declares an AIS-P condition. To enable this feature, the user must set BIT 4 (RDI-P upon AIS-P) within this register to 1. BIT 0 - Transmit RDI-P upon AIS-P This READ/WRITE bit-field is used to configure the Transmit STS-1/STS-3 POH Processor block to automatically transmit the RDI-P Code (as configured in Bits 7 through 5 - within this register) whenever the corresponding Receive STS-1/STS-3 POH Processor block declares a AIS-P condition. ` 0 - Disables the automatic transmission of RDI-P upon detection of AIS-P. ` 1 - Enables the automatic transmission of RDI-P upon detection of AIS-P. TABLE 211: TRANSMIT STS-1/STS-3 PATH - SERIAL PORT CONTROL REGISTER (ADDRESS LOCATION= 0X07CF) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 TxPOH Clock Speed[4:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:4] - Unused BIT 3:0] - TxPOHClk Output Clock Signal Speed These READ/WRITE bit-fields are used to specify the frequency of the TxPOHClk output clock signal. The formula that relates the contents of these register bits to the TxPOHClk frequency is presented below. FREQ = 51.84 /[2 * (TxPOH_CLOCK_SPEED + 1) For STS-3/STS-1/STS-3 applications, the frequency of the RxPOHClk output signal must be in the range of 2.36MHz to 25.92MHz TABLE 212: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D0) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Negative_Pointer_Adjustment_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Negative Pointer Adjustment Count - MSB This RESET-upon-READ register, along with the Transmit Negative Pointer Adjustment Count Register - Byte 0 presents a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that have occurred 157 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 (in the outbound STS-1 or STS-3 Data-stream) since the last read of this register. NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression. TABLE 213: TRANSMIT STS-1/STS-3 PATH - TRANSMIT NEGATIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 0 (ADDRESS LOCATION= 0X07D1) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Negative_Pointer_Adjustment_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Negative Pointer Adjustment Count - LSB This RESET-upon-READ register, along with the Transmit Negative Pointer Adjustment Count Register - Byte 1 presents a 16-bit representation of the number of Negative (or Decrementing) Pointer Adjustments that have occurred (in the outbound STS-1 or STS-3 Data-stream) since the last read of this register. NOTE: This register contains the LSB (Least Significant Bits) of this 16-bit expression. TABLE 214: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D2) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Positive_Pointer_Adjustment_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Positive Pointer Adjustment Count - MSB This RESET-upon-READ register, along with the Transmit Positive Pointer Adjustment Count Register - Byte 0 presents a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that have occurred (in the outbound STS-1 or STS-3 Data-stream) since the last read of this register. NOTE: This register contains the MSB (Most Significant Bits) of this 16-bit expression. TABLE 215: TRANSMIT STS-1/STS-3 PATH - TRANSMIT POSITIVE POINTER ADJUSTMENT COUNT REGISTER - BYTE 1 (ADDRESS LOCATION= 0X07D3) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit_Positive_Pointer_Adjustment_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit Positive Pointer Adjustment Count - LSB This RESET-upon-READ register, along with the Transmit Positive Pointer Adjustment Count Register - Byte 1 presents a 16-bit representation of the number of Positive (or Incrementing) Pointer Adjustments that have occurred (in the outbound STS-1 or STS-3 Data-stream) since the last read of this register. NOTE: This register contains the LSB (Least Significant Bits) of this 16-bit expression. to here 1/12/07 2.8 Transmit TUG-3 MAPPER/VC-4 POH Processor Block Registers (SDH/TUG-3 Applications Only) The register map for the Transmit TU-3 Mapper/VC-4 POH Processor block is presented an discussed in detail within the "SDH Version of the Register Map". 158 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328 device, with the Transmit TUG-3 Maper/VC-4 POH Processor block "highlighted" is presented below in Figure _. FIGURE 8. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT TUG-3 MAPPER/VC-4 POH PROCESSOR BLOCK "HIGHLIGHTED" Transmit Transmit TUG-3 TUG-3 Mapper/ Mapper/ VC-4 VC-4POH POH Processor Processor Block Block Transmit Transmit STM-1 STM-1 SOH SOH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Transmit Transmit VC-3 VC-3POH POH Processor Processor Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From TU Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block STS-1/ STS-1/ STM-0 STM-0 Telecom Telecom Bus Bus Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To TU Channels 1 - 27 Receive Receive TUG-3 TUG-3 Mapper/ Mapper/ VC-4 VC-4 POH POH Processor Processor Block Block Receive Receive STM-1 STM-1 SOH SOH Processor Processor Block Block Receive Receive VC-3 VC-3POH POH Processor Processor Block Block To DS2 Channels 1 - 6 DS1/E1 Jitter Atten Block VT/TU De-Mapper Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 For detailed on the "Transmit TUG-3 Mapper/VC-4 POH Processor Block" Registers, please see the "XRT86SH328 28-Channel DS1/E1 Framer/LIU with DS3 MUX and TU-Mapper IC - Register Map & Description - SDH Applications". 2.9 Global VT MAPPER BLOCK CONTROL REGISTERS The register map for the Global VT Mapper block is presented in the Table below. Additionally, a detailed description of each of the Global VT Mapper Control registers is presented below. TABLE 216: GLOBAL CONTROL - VT-MAPPER BLOCK - VT MAPPER BLOCK CONTROL REGISTER (ADDRESS = 0X0C03) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Latch Count REI-V Enable Unused SONET/SDH Loop-Back R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 159 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT [7:4] - Unused BIT 3 - Latch Count ` A "0 to 1" transition within this bit-field commands each of the VT-De-Mapper blocks to update the contents within the following Bit-Fields/PMON registers. BIT FIELDS REGISTER NAME ADDRESS LOCATION VT-Payload Pointer Increment Count[3:0] Channel Control VT Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 1 0xND4A BIP-2 Error Count[11:8] Channel Control VT Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 1 0xND4A BIP-2 Error Count[7:0] Channel Control VT Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 0 0xND4B VT-Payload Pointer Dec- Channel Control - VT Mapper Block - Egress Direction - REI-V rement Count[3:0] Event Count Register - Byte 1 0xND4E REI-V Event Count[11:8] Channel Control - VT Mapper Block - Egress Direction - REI-V Event Count Register - Byte 1 0xND4E REI-V Event Count[7:0] 0xND4F Channel Control - VT Mapper Block - Egress Direction - REI-V Event Count Register - Byte 0 BIT 2 - REI-V Enable This READ/WRITE bit-field is used to configure a given Transmit VT-Mapper block to automatically insert the appropriate REI-V value (based upon the number of B2 bit errors that are detected by the corresponding Receive VTMapper block) into the V5 byte, within its outbound VT1.5 or VT2 data-stream. ` 0 - Configures the Transmit VT-Mapper block to NOT automatically insert the REI-V value into each V5 byte, within the outbound VT data-stream. ` 1 - Configures the Transmit VT-Mapper block to automatically insert the REI-V value into each V5 byte, within the outbound VT data-stream. BIT 1 - Unused BIT 0 - VT Mpper SONET/SDH Loop-Back This READ/WRITE bit-field permits the user to configure the XRT86SH328 device to operate in the "VT Mapper SONET/SDH Loop-back" Mode. If the user configures the XRT86SH328 device to operate in this mode, then the outputs (from each of the 28 VT-Mapper blocks) will be internally looped back into the inputs of their corresponding VTDe-Mapper block. Figure _ presents an illustration of the XRT86SH328 device whenever it has been configured to operate in the "VT Mapper SONET/SDH Loop-back" Mode. Figure _, Illustration of the Functional Block Diagram of the XRT86SH328 device with the "VT-Mapper SONET/SDH Loop-back" path depicted. 160 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS FIGURE 9. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WITH THE VT-MAPPER SONET/SDH LOOP-BACK PATH DEPICTED Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 VT Mapper SONET/SDH Loop-Back DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 ` 0 - Does not configure the XRT86SH328 device to operate in the "VT-Mapper SONET/SDH Loop-back" Mode. ` 1 - Configures the XRT86SH328 device to operate in the "VT-Mapper SONET/SDH Loop-back" Mode. TABLE 217: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0C0E) BIT7 BIT6 BIT 5 BIT 4 Latch Error Count Insert Pattern Error R/W R/W R/O R/O 0 0 0 0 BIT 3 BIT 2 BIT 1 BIT 0 R/O R/O R/O R/O 0 0 0 0 Reserved BIT7 - Latch Error Count A 0 to 1 transition within this bit-field commands the Test Pattern Receiver to latch its current Bit Error Count into Bits 6 - 0 (Test Pattern Error Count[14:8]) and BIT [7:0] (Test Pattern Error Count[7:0]) within the VT Mapper - Test Pattern Detector Error Count Register (Address Locations = 0x0C16 and 0x0C17). BIT6 - Insert Pattern Error This bit-field is used to configure the VT-Mapper Test Pattern Generator block to insert a single bit-error into the outbound VT data-stream. A 0 to 1 transition within this bit-field will command the VT-Mapper Test Pattern Generator block to insert a single bit-error into the outbound VT data-stream. Bits [5 - 0] - Reserved 161 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 218: GLOBAL VT-MAPPER BLOCK - TEST PATTERN CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0C0F) BIT7 BIT6 BIT 5 VT1.5 Transmit Test Pattern[1:0] BIT 4 BIT 3 VT2 Transmit Test Pattern[1:0] BIT 2 VT3 Transmit Test Pattern[1:0] BIT 1 BIT 0 VT6 Transmit Test Pattern[1:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 6 - VT1.5 Transmit Test Pattern[1:0] This READ/WRITE bit-field is used to specify the test pattern that the VT1.5 Test Pattern Generator will generate and transmit. Transmitted Test Pattern VT1.5 TRANSMIT TEST PATTERN[1:0] TEST PATTERN TRANSMITTED 00 All Zeros Pattern 01 All Ones Pattern 10 Repeating 1010… Pattern 11 2^15-1 PRBS Pattern BIT[5:4] - VT2 Transmit Test Pattern[1:0] This READ/WRITE bit-field is used to specify the test pattern that the VT2 Test Pattern Generator will generate and transmit. Transmitted Test Pattern VT2 TRANSMIT TEST PATTERN[1:0] TEST PATTERN TRANSMITTED 00 All Zeros Pattern 01 All Ones Pattern 10 Repeating 1010… Pattern 11 2^15-1 PRBS Pattern BIT[3:2] - VT3 Transmit Test Pattern[1:0] This READ/WRITE bit-field is used to specify the test pattern that the VT3 Test Pattern Generator will generate and transmit. Transmitted Test Pattern VT3 TRANSMIT TEST PATTERN[1:0] TEST PATTERN TRANSMITTED 00 All Zeros Pattern 01 All Ones Pattern 10 Repeating 1010… Pattern 11 2^15-1 PRBS Pattern 162 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT[1:0] - VT6 Transmit Test Pattern[1:0] This READ/WRITE bit-field is used to specify the test pattern that the VT6 Test Pattern Generator will generate and transmit. Transmitted Test Pattern VT6 TRANSMIT TEST PATTERN[1:0] TEST PATTERN TRANSMITTED 00 All Zeros Pattern 01 All Ones Pattern 10 Repeating 1010… Pattern 11 2^15-1 PRBS Pattern TABLE 219: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 1 (ADDRESS = 0X0C12) BIT7 BIT6 Test Channel Size[1:0] BIT 5 BIT 4 Test Channel Drop Side SONET/SDH BIT 3 BIT 2 BIT 1 BIT 0 Test Channel Drop Side[4:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7-6 - Test Channel Size[1:0]: These two READ/WRITE bit-fields are used to specify the Size of the Test Channel (e.g., the Channel that will be used to transport the user-specified Test Pattern. Test Channel Size TEST CHANNEL SIZE[1:0] TEST CHANNEL SIZE 00 VT-6 01 VT-3 10 VT2/TU-12 11 VT1.5/TU-11 BIT 5 - Test Channel Drop Side SONET/SDH This READ/WRITE bit-field is used to select the source of the Test Channel. In this case, the user can either select either a DS1/E1 Channel originating from the Receive SONET/SDH Block or a DS1/E1 Channel originating from the Ingress Direction DS1/E1 Blocks. ` 0 - Configures the Test Channel Source to be one of the DS1/E1 Channels, originating from the Ingress Direction DS1/E1 Blocks. ` 1 - Configures the Test Channel Source to be the DS1/E1 Channels, originating from the Receive SONET/SDH Blocks BIT[4:0] - Test Channel Drop Side[4:0] These READ/WRITE bit-fields are used to select which data-stream will be output via the Test Channel. 163 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Output Data Stream via Test Channel TEST CHANNEL DROP SIDE[4:0] TEST CHANNEL USED 00000 Do Not Use 00001 DS1/E1 Channel 1 00010 DS1/E1 Channel 2 00011 DS1/E1 Channel 3 00100 DS1/E1 Channel 4 00101 DS1/E1 Channel 5 00110 DS1/E1 Channel 6 00111 DS1/E1 Channel 7 01000 DS1/E1 Channel 8 01001 DS1/E1 Channel 9 01010 DS1/E1 Channel 10 01011 DS1/E1 Channel 11 01100 DS1/E1 Channel 12 01101 DS1/E1 Channel 13 01110 DS1/E1 Channel 14 01111 DS1/E1 Channel 15 10000 DS1/E1 Channel 16 10001 DS1/E1 Channel 17 10010 DS1/E1 Channel 18 10011 DS1/E1 Channel 19 10100 DS1/E1 Channel 20 10101 DS1/E1 Channel 21 10110 DS1/E1 Channel 22 10111 DS1/E1 Channel 23 11000 DS1/E1 Channel 24 11001 DS1/E1 Channel 25 11010 DS1/E1 Channel 26 11011 DS1/E1 Channel 27 11100 DS1/E1 Channel 28 11101 AIS will be Generated 11110 Test Channel Input 11111 User Selected Test Pattern 164 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 220: GLOBAL CONTROL - VT-MAPPER BLOCK - TEST PATTERN DROP REGISTER - BYTE 0 (ADDRESS = 0X0C13) BIT7 BIT6 BIT 5 Receive (Expected) Pattern[1:0] BIT 4 BIT 3 Test Channel Drop Side SONET/SDH BIT 2 BIT 1 BIT 0 Test Channel Drop Side[4:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 6 - Receive (Expected) Pattern: This READ/WRITE bit-field is used to specify the Test Pattern, that the VT-Mapper Pattern Receiver should be expecting, as shown in the table below. Expected Test Pattern RECEIVE (EXPECTED) PATTERN[1:0] EXPECTED TEST PATTERN 00 All Zeros Pattern 01 All Ones Pattern 10 Repeating 1010… Pattern 11 2^15-1 PRBS Pattern BIT 5 - Test Channel Drop-Side SONET/SDH This READ/WRITE bit-field is used to select which set of DS1/E1 traffic should be used, as a basis of comparison against the Test Signal. In this case, the user can either select the either the DS1/E1 traffic originating from the Ingress Direction DS1/E1 Blocks or the DS1/E1 traffic originating from the Receive SONET/SDH Blocks. ` 0 - Configures the Pattern Receiver to compare the Test Signal with one of the DS1/E1 Channels, originating from the Ingress Direction DS1/E1 Blocks. ` 1 - Configures the Pattern Receiver to compare the Test Signal with one of the DS1/E1 Channels, originating from the Receive SONET/SDH Blocks. BIT[4:0] - Test Channel Drop Side[4:0]: These READ/WRITE bit-fields are used to select which data-stream will be compared with the Test Signal. Test Channel Selection TEST CHANNEL DROP SIDE[4:0] TEST CHANNEL USED 00000 Do Not Use 00001 DS1/E1 Channel 1 00010 DS1/E1 Channel 2 00011 DS1/E1 Channel 3 00100 DS1/E1 Channel 4 00101 DS1/E1 Channel 5 00110 DS1/E1 Channel 6 00111 DS1/E1 Channel 7 165 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Test Channel Selection TEST CHANNEL DROP SIDE[4:0] TEST CHANNEL USED 01000 DS1/E1 Channel 8 01001 DS1/E1 Channel 9 01010 DS1/E1 Channel 10 01011 DS1/E1 Channel 11 01100 DS1/E1 Channel 12 01101 DS1/E1 Channel 13 01110 DS1/E1 Channel 14 01111 DS1/E1 Channel 15 10000 DS1/E1 Channel 16 10001 DS1/E1 Channel 17 10010 DS1/E1 Channel 18 10011 DS1/E1 Channel 19 10100 DS1/E1 Channel 20 10101 DS1/E1 Channel 21 10110 DS1/E1 Channel 22 10111 DS1/E1 Channel 23 11000 DS1/E1 Channel 24 11001 DS1/E1 Channel 25 11010 DS1/E1 Channel 26 11011 DS1/E1 Channel 27 11100 DS1/E1 Channel 28 11101 AIS will be Generated 11110 Test Channel Input 11111 Disable Pattern Receiver TABLE 221: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - UPPER BYTE (ADDRESS = 0X0C16) BIT7 BIT6 BIT 5 VT-Mapper Test Pattern Sync BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Test Pattern Error Count[14:8] R/O RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT7 - VT-Mapper Test Pattern Sync: 166 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This READ-ONLY bit-field indicates whether or not the VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the incoming Test Signal. ` 0 - VT-Mapper Pattern Receiver is NOT currently declaring Pattern Sync with the incoming Test Signal. ` 1 - VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the incoming Test Signal. BIT[6:0] - Test Pattern Error Count[14:8]: These seven (7) RESET-upon-READ bit-fields, along with the Test Pattern Error Count[7:0] bit-fields function as a 15bit Pattern Bit Error Count Register. If the VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the designated Test Signal, then it will increment this register (by the value of 1) each time that it detects Pattern Bit Error. These seven (7) bit-fields function as the seven most-significant bits of this 15-bit counter. TABLE 222: GLOBAL CONTROL - VT-MAPPER - TEST PATTERN DETECTOR ERROR COUNT REGISTER - LOWER BYTE (ADDRESS = 0X0C17) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Test Pattern Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT[7:0] - Test Pattern Error Count[7:0]: These eight (8) RESET-upon-READ bit-fields, along with the Test Pattern Error Count[14:8] bit-fields function as a 15bit Pattern Bit Error Count Register. If the VT-Mapper Pattern Receiver is currently declaring Pattern Sync with the designated Test Signal, then it will increment this register (by the value of 1) each time that it detects Pattern Bit Error. These eight (8) bit-fields function as the eight least-significant bits of this 15-bit counter. TABLE 223: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1A) BIT7 BIT6 Unused BIT 5 BIT 4 BIT 3 TxTributary Size Select VT#6[1:0] BIT 2 TxTributary Size Select VT#5[1:0] BIT 1 BIT 0 TxTributary Size Select VT#4[1:0] R/O R/O R/W R/W R/W R/W R/W R/W 0 0 1 1 1 1 1 1 Bits 7 - 6 - Unused: BIT[5:4] - Transmit Tributary Size Select for VT# 6[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper block (associated with Virtual Tributary Group # 6) will support. Size of VT #6 TXTRIBUTARY SIZE SELECT - VT#6[1:0] RESULTING SIZE OF VT # 6 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 NOTE: This configuration setting only applies to the Transmit VT-Mapper block. This configuration setting does not configure the Receive VT-De-Mapper block to expect any particular VT-type within VT Group # 6. The user 167 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 must separately configure the Receive VT-De-Mapper block's handling of VT-Group # 6 by setting Bits 4 and 5 (RxTributary Size Select - VT# 6[1:0]) within the VT-Mapper - Receive Tributary Size Select Register (Address = 0x0C1E). BIT[3:2] - Transmit Tributary Size Select for VT# 5[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper block (associated with Virtual Tributary Group # 5) will support. Size of VT #5 TXTRIBUTARY SIZE SELECT - VT#5[1:0] RESULTING SIZE OF VT # 5 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[1:0] - Transmit Tributary Size Select for VT# 4[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper block (associated with Virtual Tributary Group # 4), will support. Size of VT #4 TXTRIBUTARY SIZE SELECT - VT#4[1:0] RESULTING SIZE OF VT # 4 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 TABLE 224: GLOBAL CONTROL - VT-MAPPER - TRANSMIT TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1B) BIT7 BIT6 TxTributary Size Select VT#3[1:0] BIT 5 BIT 4 BIT 3 TxTributary Size Select VT#2[1:0] BIT 2 TxTributary Size Select VT#1[1:0] BIT 1 BIT 0 TxTributary Size Select VT#0[1:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 Bits 7 - 6 - Transmit Tributary Size Select for VT# 3[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper block (associated with Virtual Tributary Group # 3), will support. TxTributary Size Select of VT#3 TXTRIBUTARY SIZE SELECT - VT#3[1:0] RESULTING SIZE OF VT # 3 00 VT-6 01 VT-3 168 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TxTributary Size Select of VT#3 TXTRIBUTARY SIZE SELECT - VT#3[1:0] RESULTING SIZE OF VT # 3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[5:4] - Transmit Tributary Size Select for VT# 2[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper block (associated with Virtual Tributary Group # 2) will support. TxTributary Size Select of VT#2 TXTRIBUTARY SIZE SELECT - VT#2[1:0] RESULTING SIZE OF VT # 2 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[3:2] - Transmit Tributary Size Select for VT# 1[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper block (associated with Virtual Tributary Group # 1) will support. TxTributary Size Select of VT#1 TXTRIBUTARY SIZE SELECT - VT#1[1:0] RESULTING SIZE OF VT # 1 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[1:0] - Transmit Tributary Size Select for VT# 0[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Transmit VT-Mapper Block (associated with Virtual Tributary Group # 0) will support. TxTributary Size Select of VT#0 TXTRIBUTARY SIZE SELECT - VT#0[1:0] RESULTING SIZE OF VT # 0 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 169 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 225: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1E) BIT7 BIT6 Unused BIT 5 BIT 4 BIT 3 RxTributary Size Select VT#6[1:0] BIT 2 RxTributary Size Select VT#5[1:0] BIT 1 BIT 0 RxTributary Size Select VT#4[1:0] R/O R/O R/W R/W R/W R/W R/W R/W 0 0 1 1 1 1 1 1 Bits 7 - 6 - Unused: BIT[5:4] - Receive Tributary Size Select for VT# 6[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper Block (associated with Virtual Tributary Group # 6) will support. Resulting Size of VT#6 RXTRIBUTARY SIZE SELECT - VT#6[1:0] RESULTING SIZE OF VT # 6 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[3:2] - Receive Tributary Size Select for VT# 5[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper block (associated with Virtual Tributary Group # 5) will support. Resulting Size of VT#5 RXTRIBUTARY SIZE SELECT - VT#5[1:0] RESULTING SIZE OF VT # 5 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[1:0] - Receive Tributary Size Select for VT# 4[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper block (associated with Virtual Tributary Group # 4) will support. Resulting Size of VT#4 RXTRIBUTARY SIZE SELECT - VT#4[1:0] RESULTING SIZE OF VT # 4 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 170 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 226: GLOBAL CONTROL - VT-MAPPER - RECEIVE TRIBUTARY SIZE SELECT REGISTER (ADDRESS = 0X0C1F) BIT7 BIT6 RxTributary Size Select VT#3[1:0] BIT 5 BIT 4 BIT 3 RxTributary Size Select VT#2[1:0] BIT 2 RxTributary Size Select VT#1[1:0] BIT 1 BIT 0 RxTributary Size Select VT#0[1:0] R/W R/W R/W R/W R/W R/W R/W R/W 1 1 1 1 1 1 1 1 BIT[7:6] - Receive Tributary Size Select for VT# 3[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper block (associated with Virtual Tributary Group # 3) will support. Resulting Size of VT#3 RXTRIBUTARY SIZE SELECT - VT#3[1:0] RESULTING SIZE OF VT # 3 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[5:4] - Receive Tributary Size Select for VT# 2[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper block (associated with Virtual Tributary Group # 2) will support. Resulting Size of VT#2 RXTRIBUTARY SIZE SELECT - VT#2[1:0] RESULTING SIZE OF VT # 2 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 BIT[3:2] - Receive Tributary Size Select for VT# 1[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper block (associated with Virtual Tributary Group # 1) will support. Resulting Size of VT#1 RXTRIBUTARY SIZE SELECT - VT#1[1:0] RESULTING SIZE OF VT # 1 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 171 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT[1:0] - Receive Tributary Size Select for VT# 0[1:0]: These two READ/WRITE bit-fields are used to specify the VT-size (or the bit-rate to be supported by) that the Receive VT-Mapper block (associated with Virtual Tributary Group # 0) will support. Resulting Size of VT#0 RXTRIBUTARY SIZE SELECT - VT#0[1:0] 2.10 RESULTING SIZE OF VT # 0 00 VT-6 01 VT-3 10 VT-2/TU-12 11 VT-1.5/TU-11 DS3 MAPPER CONTROL REGISTERS TABLE 227: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D02) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 Default_R Default_O R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 1 1 BIT[7:0] - Reserved BIT 1 - Default_R Value: When a DS3 signal is mapped into an STS-1/STS-3 SPE or a VC-3, there are numerous bits that are also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency differences between DS3 and an STS1/STS-3 SPE or an SDH VC-3. One such bit is referred to as an R bit. Currently, the standards do not define a use for these bits. Hence, this bit can be used as a proprietary communication link between two pieces of equipment. This READ/WRITE bit-field is used to set the value for the R bits in the outbound STS-1/STS-3 SPE or SDH VC-3. NOTES: 1. The XRT86SH328 includes a corresponding READ-ONLY register bit, in which one can obtain the value for the R bits in the incoming STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 1 (Received R) within the DS3 Mapper Block - Receive Status Register - Byte 1 (Address = 0x0D06). 2. This register bit is only active if the XRT86SH328 has been configured to operate in the M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode. BIT 0 - Default_O Value: When a DS3 signal is mapped into a STS-1/STS-3 SPE (in SONET) or a VC-3 (in SDH), there are numerous bits that are also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency differences between DS3 and an STS-1/STS-3 SPE or an SDH VC-3. One such bit is referred to as an 0 bit. Currently, the standards do not define a use for these bits. Hence, this bit can be used as a proprietary communication link between two pieces of equipment. This READ/WRITE bit-field is used to set the value for the O bits in the outbound STS-1/STS-3 SPE or SDH VC-3. NOTES: 1. The XRT86SH328 includes a corresponding READ-ONLY register bit in which one can obtain the value for the O bits in the incoming STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 0 (Received O) within the DS3 Mapper Block - Receive Status Register - Byte 1 (Address = 0x0D06). 2. This register bit is only active if the XRT86SH328 has been configured to operate in the M13 MUX Asynchronously Mapped into STS-1/STS-3 Mode. 172 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 228: DS3 MAPPER BLOCK - CONTROL REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D03) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Gap Clock in Egress T1/E1 R/O R/O R/O R/O R/O R/O R/O R/W 0 0 0 0 0 0 0 0 BIT[7:1] - Reserved BIT 0 - Gap Clock in Egress T1/E1 This READ/WRITE bit-field permits the user to apply some "clock-smoothing" to the Egress Direction T1/E1 signals prior to being routed to the Transmit DS1/E1 LIU Block, as depicted below. ` 0 - Configures the chip to perform "clock-smoothing" on all Egress Direction T1/E1 signals prior to being routed to the Transmit DS1/E1 LIU Blocks. ` 1- Disables this "clock-smoothing" feature. TABLE 229: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 1 (ADDRESS LOCATION = 0X0D06) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 Received_R Received_O R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 1 1 BIT[7:2] - Reserved: BIT 1 - Received_R: When a DS3 signal is de-mapped from an STS-1/STS-3 SPE (in SONET) or a VC-3 (in SDH), there are numerous bits that were also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency differences between DS3 and an STS-1/STS-3 SPE or an SDH VC-3. One such bit is referred to as an R bit. Currently, the standards do not define a use for these bits. Hence, this bit can be used as a proprietary communication link between two pieces of equipment. This READ-ONLY bit-field contains the value of the R bits within the most recently received STS-1/STS-3 SPE or SDH VC-3. NOTE: The XRT86SH328 includes a corresponding READ/WRITE register bit, in which one can set the value for the R bits, in the outbound STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 1 (Default_R) within the DS3 Mapper Block - Control Register - Byte 1 (Address = 0x0D02). BIT 0 - Received_O: When a DS3 signal is de-mapped from an STS-1/STS-3 SPE (in SONET) or a VC-3 (in SDH), there are numerous bits that were also stuffed into the STS-1/STS-3 SPE or the VC-3 in order to accommodate the frequency difference between DS3 and an STS-1/STS-3 SPE or an SDH VC-3. One such bit is referred to as an O bit. Currently, the standards do not define a use for these bits. Hence, this bit can be used as a proprietary communication link between two pieces of equipment. This READ-ONLY bit-field contains the value of the O bits within the most recently received STS-1/STS-3 SPE or SDH VC-3. NOTE: The XRT86SH328 includes a corresponding READ/WRITE register bit, in which one can set the value for the R bits, in the outbound STS-1/STS-3 SPE or SDH VC-3. This register bit is located in BIT 1 (Default R) within the DS3 Mapper Block - Control Register - Byte 1 (Address = 0x0D02). 173 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 230: DS3 MAPPER BLOCK - RECEIVE STATUS REGISTER - BYTE 0 (ADDRESS LOCATION = 0X0D07) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 Receive FIFO Overrun Receive FIFO Underrun Transmit FIFO Overrun Transmit FIFO Underrun R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT[7:4] - Reserved: BIT 3 - Receive FIFO Overrun This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring a Receive FIFO Overrun condition. A Receive FIFO Overrun condition will only occur if DS3 data is output from the DS3 Mapper block to the Receive DS3 Framer block at a much faster rate than that which the Receive DS3 Framer block handles and processes the incoming DS3 data-stream. ` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Receive FIFO Overrun condition. ` 1 - Indicates that the DS3 Mapper Block is currently declaring the Receive FIFO Overrun condition. BIT 2 - Receive FIFO Underrun This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring the Receive FIFO Underrun condition. A Receive FIFO Underrun condition will only occur if DS3 data is output from the DS3 Mapper block to the Receive DS3 Framer block at a much slower rate than that which the Receive DS3 Framer block handles and processes the incoming DS3 data-stream. ` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Receive FIFO Underrun condition. ` 1 - Indicates that the DS3 Mapper Block is currently declaring the Receive FIFO Underrun condition. BIT 1 - Transmit FIFO Overrun This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring a Transmit FIFO Overrun condition. A Transmit FIFO Overrun condition will occur if DS3 data is output from the Transmit DS3 Framer block (towards the DS3 Mapper Block) at a much faster rate than which the DS3 Mapper block handles and processes the outbound DS3 data-stream. ` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Transmit FIFO Overrun condition. ` 1 - Indicates that the DS3 Mapper Block is currently declaring the Transmit FIFO Overrun condition. BIT 0 - Transmit FIFO Underrun This READ-ONLY bit-field indicates whether or not the DS3 Mapper block is currently declaring a Transmit FIFO Underrun condition. A Transmit FIFO Underrun condition will occur if DS3 data is output from the Transmit DS3 Framer block (towards the DS3 Mapper Block) at a much slower rate than that which the DS3 Mapper Block handles and processes the outbound DS3 data-stream. ` 0 - Indicates that the DS3 Mapper Block is NOT currently declaring the Transmit FIFO Underrun condition. ` 1 - Indicates that the DS3 Mapper Block is currently declaring the Transmit FIFO Underrun condition. 174 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 231: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D0B) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 Receive FIFO Overrun Interrupt Status Receive FIFO Underrun Interrupt Status Transmit FIFO Overrun Interrupt Status Transmit FIFO Underrun Interrupt Status R/O R/O R/O R/O RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT[7:4] - Reserved BIT 3 - Receive FIFO Overrun Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Receive FIFO Overrun interrupt has occurred since the last read of this register. If this interrupt is enabled, then the DS3 Mapper block will generate this interrupt anytime it declares a Receive FIFO Overrun condition. ` 0 - Indicates that the Receive FIFO Overrun interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Receive FIFO Overrun interrupt has occurred since the last read of this register. NOTE: The user can obtain the current status of the Receive FIFO Overrun condition by reading the state of BIT 3 (Receive FIFO Overrun Condition) within the DS3 Mapper - Status Register - Byte 0 (Address = 0x0D07). BIT 2 - Receive FIFO Underrun Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Receive FIFO Underrun interrupt has occurred since the last read of this register. If this interrupt is enabled, then the DS3 Mapper Block will generate this interrupt anytime it declares a Receive FIFO Underrun condition. ` 0 - Indicates that the Receive FIFO Underrun interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Receive FIFO Underrun interrupt has occurred since the last read of this register. NOTE: The user can obtain the current status of the Receive FIFO Underrun condition by reading the state of BIT 2 (Receive FIFO Underrun Condition) within the DS3 Mapper - Status Register - Byte 0 (Address = 0x0D07). BIT 1 - Transmit FIFO Overrun Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Transmit FIFO Overrun interrupt has occurred since the last read of this register. If this interrupt is enabled, then the DS3 Mapper block will generate this interrupt anytime it declares a Transmit FIFO Overrun condition. ` 0 - Indicates that the Transmit FIFO Overrun Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Transmit FIFO Overrun Interrupt has occurred since the last read of this register. NOTE: The user can determine the current status of the Transmit FIFO Overrun condition by reading the state of BIT 1 (Transmit FIFO Overrun Condition) within the DS3 Mapper Block - Status Register - Byte 0 (Address = 0x0D07). BIT 0 - Transmit FIFO Underrun Interrupt Status This RESET-upon-READ bit-field indicates whether or not the Transmit FIFO Underrun interrupt has occurred since the last read of this register. If this interrupt is enabled, then the DS3 Mapper block will generate this interrupt anytime it declares a Transmit FIFO Underrun condition. ` 0 - Indicates that the Transmit FIFO Underrun interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Transmit FIFO Underrun interrupt has occurred since the last read of this register. 175 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 NOTE: The user can determine the current state of the Transmit FIFO Underrun condition by reading the state of BIT 0 (Transmit FIFO Underrun Condition) within the DS3 Mapper Block - Status Register - Byte 0 (Address = 0x0D07). TABLE 232: DS3 MAPPER BLOCK - RECEIVE MAPPER INTERRUPT ENABLE REGISTER - BYTE 0 (ADDRESS = 0X0D0E) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 Receive FIFO Overrun Interrupt Enable Receive FIFO Underrun Interrupt Enable Transmit FIFO Overrun Interrupt Enable Transmit FIFO Underrun Interrupt Enable R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT[7:4] - Reserved: BIT 3 - Receive FIFO Overrun Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Receive FIFO Overrun Interrupt. If this interrupt is enabled, then the DS3 Mapper block will generate an interrupt anytime it declares the Receive FIFO Overrun condition. ` 0 - Disables this interrupt. ` 1 - Enables this interrupt. BIT 2 - Receive FIFO Underrun Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the 'Receive FIFO Underrun interrupt. If this interrupt is enabled, then the DS3 Mapper Block will generate an interrupt anytime it declares the Receive FIFO Underrun condition. ` 0 - Disables this interrupt. ` 1 - Enables this interrupt. BIT 1 - Transmit FIFO Overrun Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Transmit FIFO Overrun interrupt. If this interrupt is enabled, then the DS3 Mapper block will generate an interrupt anytime it declares the Transmit FIFO Overrun condition. ` 0 - Disables this interrupt. ` 1 - Enables this interrupt. BIT 0 - Transmit FIFO Underrun Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Transmit FIFO Underrun interrupt. If this interrupt is enabled, then the DS3 Mapper block will generate an interrupt anytime that the DS3 Mapper block declares the Transmit FIFO Underrun condition. ` 0 - Disables this interrupt. ` 1 - Enables this interrupt. TABLE 233: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 2 (ADDRESS = 0X0D21) BIT7 BIT6 BIT 5 BIT 4 BIT 3 PStuff BIT 2 BIT 1 BIT 0 Unused R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT7 - Pstuff: 176 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT[6:0] - Unused: TABLE 234: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 1 (ADDRESS = 0X0D22) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 TABLE 235: DS3 MAPPER BLOCK - POINTER JUSTIFICATION STATUS REGISTER - BYTE 0 (ADDRESS = 0X0D23) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 TABLE 236: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 1 (ADDRESS = 0X0D26) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 TABLE 237: DS3 MAPPER BLOCK - POINTER JUSTIFICATION JITTER CONTROL REGISTER - BYTE 0 (ADDRESS = 0X0D27) BIT7 2.11 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS3 Framer and M13 MUX Block Registers The register map for the DS3 Framer and M13 MUX block is presented in the Tables below. Additionally, a detailed description of each of the DS3 Framer and M13 MUX Block registers is presented below. In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328, with the various functions that are controlled/monitored via the DS3 Framer and M13 MUX Block Register highlighted is presented below in Figure 10. 177 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 10. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WITH THE FUNCTIONAL BLOCKS (WHICH ARE CONTROLLED/MONITORED VIA THE DS3 FRAMER AND M13 MUX BLOCK REGISTERS) HIGHLIGHTED. Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 NOTE: These functional blocks are only active if the XRT86SH328 has been configured to operate in either the M13 MUX or in the M13 MUX, which is Asynchronously Mapped into STS-1/STS-3 Mode. TABLE 238: DS3 FRAMER BLOCK OPERATING MODE REGISTER (ADDRESS = 0X0E00) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS3 Framer Local LoopBack Set DS3 Mode Internal LOS Enable DS3 Framer Block Software RESET Reserved Frame Format R/W R/W R/W R/W R/O R/W R/W R/W 0 1 1 0 0 0 1 1 TimRefSel[1:0] BIT7 - DS3 Framer Local Loop-back Mode: This READ/WRITE bit-field is used to configure the DS3/E3 Framer block to operate in the DS3 Framer block to operate in the DS3 Framer Local Loop-back Mode. If the DS3 Framer block has been configured to operate in the Framer Local Loop-back Mode, then the output of the Transmit DS3 Framer block will be internally looped-back into the Receive DS3 Framer block. ` 0 - Configures the DS3/E3 Framer block to operate in the Normal Operation (e.g., Non-DS3 Framer Local Loop-back) mode ` 1 - Configures the DS3/E3 Framer block to operate in the DS3 Framer Local Loop-back Mode. 178 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT6 - Set DS3 Mode To use the Transmit and Receive DS3 Framer blocks, within the XRT86SH328, then the user MUST set this bit-field to 1. BIT 5 - Internal LOS Enable This READ/WRITE bit-field is used to enable or disable the Internal LOS Detector within the Receive DS3 Framer block. If the user enables the Internal LOS Detector, then the Receive DS3 Framer block will be configured to check the incoming DS3 signal for a sufficient number of consecutive all zero bits and it will declare and clear the LOS defect condition based upon the 1s density and the number of consecutive 0bits within the incoming DS3 data-stream. If the user disables the Internal LOS Detector, then the Receive DS3 Framer block will NOT be configured to check the incoming DS3 data-stream for a sufficient number of consecutive 0 bits, and it will NOT declare nor clear the LOS defect condition based upon the 1s density and the number of consecutive 0 bits within the incoming DS3 data-stream. ` 0 - Disables the Internal LOS Detector ` 1 - Enables the Internal LOS Detector. BIT 4 - DS3 Framer Block Software RESET This READ/WRITE bit-field is used to execute a Software RESET to the Transmit and Receive DS3 Framer block. If the user executes this Software RESET, then the contents of the Transmit/Receive DS3 Framer block configuration registers will not be reset to their default values. Instead, internal state machines (within the Transmit and Receive DS3 Framer blocks) will be reset. ` A 0 to 1 transition in this bit-field commands a Software RESET to Transmit and Receive DS3 Framer block. BIT 3 - Reserved BIT 2 - Frame Format This READ/WRITE bit-field is used to configure the Transmit and Receive DS3 Framer blocks to operate in either the C-Bit Parity or the M13/M23 Framing formats. ` 0 - Configures the Transmit and Receive DS3 Framer blocks to operate in the C-bit Parity Framing format. ` 1 - Configures the Transmit and Receive DS3 Framer blocks to operate in the M13/M23 Framing format. BIT[1:0] - Transmit DS3 Framer Block Timing Reference Select[1:0] The user should set these bit-fields to either [1, 0] or [1, 1] for proper operation. TABLE 239: DS3 FRAMER BLOCK - I/O CONTROL REGISTER (ADDRESS = 0X0E01) BIT7 BIT6 BIT 5 BIT 4 Disable TxLOC LOC Disable RxLOC R/W R/O R/W R/O 1 0 1 0 BIT 3 BIT 2 BIT 1 BIT 0 Transmit Line Clock Invert Receive Line Clock Invert Reframe R/O R/W R/W R/W 0 0 0 0 Unused BIT7 - Disable Transmit Loss of Clock Feature This READ/WRITE bit-field is used to either enable or disable the Transmit Loss of Clock feature. If this feature is enabled, then the DS3 Framer block will enable some circuitry that will terminate the current READ or WRITE access (to the Microprocessor Interface), if a Loss of Transmit Clock Event were to occur. The intent behind this feature is to prevent any READ/WRITE accesses (to the DS3 Framer blocks) from hanging in the event of a Loss of Clock event. ` 0 - Enables the Transmit Loss of Clock feature. ` 1 - Disables the Transmit Loss of Clock feature BIT6 - LOC BIT 5 - Disable Receive Loss of Clock Feature This READ/WRITE bit-field is used to either enable or disable the Receive Loss of Clock feature. If this feature is enabled, then the DS3 Framer block will enable some circuitry that will terminate the current READ or 179 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 WRITE access (to the Microprocessor Interface), if a Loss of Receive Clock Event were to occur. The intent behind this feature is to prevent any READ/WRITE accesses (to the DS3 Framer blocks) from hanging in the event of a Loss of Clock event. ` 0 - Enables the Receive Loss of Clock feature. ` 1 - Disables the Receive Loss of Clock feature Bits 4 -3 - Unused BIT 2 - Transmit Line Clock Invert This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to update the TxDS3POS and TxDS3NEG output pins upon either the rising or falling edge of TxDS3LineClk. ` 0 - Configures the Transmit DS3 Framer block to update the TxDS3POS/TxDS3NEG upon the rising edge of the TxDS3LineClk. The user should insure that the LIU IC will sample TxDS3POS/TxDS3NEG upon the falling edge of TxDS3LineClk. ` 1 - Configures the Transmit DS3 Framer block to update the TxDS3POS/TxDS3NEG upon the falling edge of the TxDS3LineClk. The user should insure that the LIU IC will sample TxDS3POS/TxDS3NEG upon the rising edge of TxDS3LineClk. BIT 1 - Receive Line Clock Invert This READ/WRITE bit-field is used to configure Receive DS3 Framer block to sample and latch the RxDS3POS/RxDS3NEG input pins upon either the rising or falling edge of RxDS3LineClk. ` 0 - Configures the Receive DS3 Framer block to sample the RxDS3POS/RxDS3NEG input pins upon the falling edge of the RxDS3LineClk input signal. ` 1 - Configures the Receive DS3 Framer block to sample the RxDS3POS/RxDS3NEG input pins upon the rising edge of the RxDS3LineClk input signal. BIT 0 - Receive DS3 Framer Block - Reframe Command A 0 to 1 transition, within this bit-field commands the Receive DS3 Framer block to exit the Frame Maintenance Mode, and go back and enter the Frame Acquisition Mode. NOTE: The user should go back and set this bit-field to 0 following execute of the Reframe Command. TABLE 240: DS3 FRAMER BLOCK - BLOCK INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E04) BIT 7 BIT 6 Receive DS3 Framer Block Interrupt Enable BIT 5 Unused BIT 4 BIT 3 M13 MUX Block Interrupt Enable BIT 2 Unused BIT 1 BIT 0 Transmit DS3 Framer Block Interrupt Enable One Second Interrupt Enable R/W R/O R/O R/W R/O R/O R/W R/W 0 0 0 0 0 0 0 0 Bit 7 - Receive DS3 Framer Bock Interrupt Enable: This READ/WRITE bit-field is used to enable or disable the Receive DS3 Framer Block for Interrupt Generation. If the user enables the Receive DS3 Framer block (for Interrupt Generation) at the block level, the user still needs to enable the interrupts at the Source Level, as well, in order for these interrupt to be enabled. However, if the user disables the Receive DS3 Framer block (for Interrupt Generation) at the Block Level, then ALL Receive DS3 Framer-related blocks are disabled. ` 0 - Disables all Receive DS3 Framer blocks interrupts. ` 1 - Enables the Receive DS3 Framer block for Interrupt Generation (at the Block Level) Bits 6 - 5 - Unused: Bit 4 - M13 MUX Block Interrupt Enable: This READ/WRITE bit-field is used to enable or disable the M13 MUX block for Interrupt Generation. If the user enables 180 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS the M13 MUX block (for Interrupt Generation) at the block level, the user still needs to enable the interrupts at the Source level as well, in order for these interrupts to be enabled. However, if the user disables the M13 MX block (for Interrupt Generation) at the Block Level, then ALL M13 MUX blockrelated interrupts are disabled. ` 0 - Disables all M13 MUX block-related interrupts. ` 1 - Enables all M13 MUX block-related interrupts. Bits 3 - 2 - Unused Bit 1 - Transmit DS3 Framer Block Interrupt Enable: This READ/WRITE bit-field is used to enable or disable the Transmit DS3 Framer block for Interrupt Generation. If the user enables the Transmit DS3 Framer block (for Interrupt Generation) at the block level, the user still needs to enable the interrupts at the Source level as well, in order for these interrupts to be enabled. However, if the user disables the Transmit DS3 Framer block (for Interrupt Generation) at the Block Level, then ALL Transmit DS3 Framer block-related interrupts are disabled. ` 0 - Disables all Transmit DS3 Framer block-related Interrupts. ` 1 - Enables the Transmit DS3 Framer block for Interrupt Generation (at the Block Level). Bit 0 - One Second Interrupt Enable: This READ/WRITE bit-field is used to enable or disable the One-Second Interrupt within the DS3/E3 Framer block. If the user enables this interrupt, then the DS3/E3 Framer block will generate an interrupt at one second intervals. 0 - Disables the One Second Interrupt 1 - Enables the One Second Interrupt. TABLE 241: DS3 FRAMER BLOCK - BLOCK INTERRUPT STATUS REGISTER (ADDRESS = 0X0E05) BIT 7 BIT 6 Receive DS3 Framer Block Interrupt Status BIT 5 Unused BIT 4 BIT 3 M13 MUX Block Interrupt Status BIT 2 Unused BIT 1 BIT 0 Transmit DS3 Framer Block Interrupt Status One Second Interrupt Status RUR R/O R/O RUR R/O R/O RUR RUR 0 0 0 0 0 0 0 0 Bit 7 - Receive DS3 Framer Bock Interrupt Status: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is requesting interrupt service. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently requesting interrupt service. ` 1 - Indicates that the Receive DS3 Framer block is currently requesting interrupt service. Bits 6 - 5 - Unused: Bit 4 - M13 MUX Block Interrupt Status: This READ-ONLY bit-field indicates whether or not the M13 MUX block is requesting interrupt service. ` 0 - Indicates that the M13 MUX block is NOT currently requesting interrupt service. ` 1 - Indicates that the M13 MUX block is currently requesting interrupt service. Bits 3 - 2 - Unused Bit 1 - Transmit DS3 Framer Block Interrupt Status: This READ-ONLY bit-field indicates whether or not the Transmit DS3 Framer block is requesting interrupt service. ` 0 - Indicates that the Transmit DS3 Framer block is NOT currently requesting interrupt service. ` 1 - Indicates that the Transmit DS3 Framer block is currently requesting interrupt service. Bit 0 - One Second Interrupt Status: 181 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This RESET-upon-READ bit-field indicates whether or not a One Second interrupt has occurred since the last read of this register. ` 0 - Indicates that the One Second Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the One Second Interrupt has occurred since the last read of this register. TABLE 242: DS3 FRAMER BLOCK - M23 CONFIGURATION REGISTER (ADDRESS = 0X0E07) BIT7 BIT6 BIT 5 BIT 4 Must Set to 0 BIT 3 BIT 2 M13 Local Loop-back Mode Reserved BIT 1 BIT 0 M23 Loop-Back Codes[1:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT[7:4] - Must Set to 0: Each of these READ/WRITE bit-fields MUST be set to 0 for proper operation. BIT 3 - M13 Local Loop-back Mode This READ/WRITE bit-field is used to configure the XRT86SH328 to operate in the M13 Local Loop-Back Mode. If the user configures the XRT86SH328 to operate in the M23 Local Loop-back Mode, then the output of the M23 MUX Block will be internally routed to the input of the M13 DEMUX Block. ` 0 - Configures the XRT86SH328 to operate in the Normal Mode ` 1 - Configures the XRT86SH328 to operate in the M13 Local Loop-back Mode Figure 11 presents an illustration of the XRT86SH328, whenever it has been configured to operate in the M13 Local Loop-back Mode. 182 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS FIGURE 11. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN CONFIGURED TO OPERATE IN THE M13 LOCAL LOOP- BACK MODE STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface Transmit Transmit DS3 DS3 Framer Framer Block Block M23 M23 MUX MUX Block Block Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 M12 De-MUX Block DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 DS1/E1 Jitter Atten Block VT/TU De-Mapper Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT 2 - Reserved BIT[1:0] - M23 Loop-back Codes[1:0] These READ/WRITE bit-fields are used to specify the coding (or the values that the Transmit DS3 Framer block will set the C-bits to) in order to request the remote terminal equipment to operate in the remote DS3 Loop-back Mode. Codes to Request Remote DS3 Loop-Back Mode M23 LOOP-BACK CODES[1:0] C-BIT SETTINGS TO REQUEST DS2 LOOP-BACK CODES COMMENTS 00/11 Cj1 = Cj2 = Cj3* The Transmit DS3 Framer block will invert the state of the Cj3 bit (from that of the corresponding Cj1 and Cj2 bits) in order to request that the remote terminal execute a DS2 remote Loop-back within the jth DS2 Channel. 01 Cj1 = Cj2* = Cj3 The Transmit DS3 Framer block will insert the state of the of the Cj2 bit (from that of the corresponding Cj1 and Cj3 bits) in order to request that the remote terminal execute a remote Loop-back within the jth DS2 Channel. 10 Cj1* = Cj2 = Cj3 The Transmit DS3 Framer block will invert the state of the Cj1 bit (from that of the corresponding Cj2 and Cj3 bits) in order to request that the remote terminal execute a remote Loop-back within the jth DS2 Channel. NOTE: Anytime the Transmit DS3 Framer block has been configured to transmit a DS2 Loop-back request code to the remote terminal equipment, then it will set the C-bits to the appropriate value (based upon the user-selection) as specified in the above table. Further, the Transmit DS3 Framer block will transmit these DS2 Loop-back request codes (to the remote terminal equipment) for the appropriate DS2 channel, whenever the user 183 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 commands it to do so by setting any one of the bits within the DS3 Framer Block - M23 - DS2 Loop-back Request Register (Address = 0x0E09) to 1. TABLE 243: DS3 FRAMER BLOCK - M23 TRANSMIT DS2 AIS COMMAND REGISTER (ADDRESS = 0X0E08) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Transmit DS2 AIS - DS2 Channel 6 Transmit DS2 AIS - DS2 Channel 5 Transmit DS2 AIS - DS2 Channel 4 Transmit DS2 AIS - DS2 Channel 3 Transmit DS2 AIS - DS2 Channel 2 Transmit DS2 AIS - DS2 Channel 1 Transmit DS2 AIS - DS2 Channel 0 R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved BIT6 - Transmit DS2 AIS - DS2 Channel 6: This READ/WRITE bit-field is used to configure the M12 MUX block (associated with DS2 Channel 6) to transmit the DS2 AIS indicator, towards the Transmit DS3 Framer block (and within the outbound DS3 data-stream). ` 0 - Configures the M12 MUX block (associated with DS2 Channel 6) to transmit normal data. ` 1 - Configures the M12 MUX block (associated with DS2 Channel 6) to transmit the DS2 AIS indicator. Figure 12 presents an illustration of the XRT86SH328, whenever the M12 MUX has been configured to transmit the DS2 AIS indicator towards both the M23 MUX and the Transmit DS3 Framer blocks. FIGURE 12. AN ILLUSTRATION OF THE XRT86SH328, WHENEVER THE M12 MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR TOWARDS BOTH THE M23 MUX AND THE TRANSMIT DS3 FRAMER BLOCK Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface Transmit Transmit DS3 DS3 Framer Framer Block Block M23 M23 MUX MUX Block Block Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 MUX Block DS2 AIS Pattern M12 De-MUX Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block From DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT 5 - Transmit DS2 AIS - DS2 Channel 5: See BIT6 description. 184 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT 4 - Transmit DS2 AIS - DS2 Channel 4: See BIT6 description. TBIT 3 - Transmit DS2 AIS - DS2 Channel 3: See BIT6 description. BIT 2 - Transmit DS2 AIS - DS2 Channel 2: See BIT6 description. BIT 1 - Transmit DS2 AIS - DS2 Channel 1: See BIT6 description. BIT 0 - Transmit DS2 AIS - DS2 Channel 0 See BIT6 description. TABLE 244: DS3 FRAMER BLOCK - M23 - DS2 LOOP-BACK REQUEST REGISTER (ADDRESS = 0X0E09) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Transmit DS2 Loopback Request DS2 Channel 6 Transmit DS2 Loopback Request DS2 Channel 5 Transmit DS2 Loopback Request DS2 Channel 4 Transmit DS2 Loopback Request DS2 Channel 3 Transmit DS2 Loopback Request DS2 Channel 2 Transmit DS2 Loopback Request DS2 Channel 1 Transmit DS2 Loopback Request DS2 Channel 0 R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT6 - Transmit DS2 Loop-back Request - DS2 Channel 6: This READ/WRITE bit-field is used to command the Transmit DS3 Framer block to transmit the Loop-back Request indicator, for DS2 Channel 6. ` 0 - The Transmit DS3 Framer block will NOT transmit the Loop-back Request for DS2 Channel #6 (Normal Operation) ` 1 - The Transmit DS3 Framer block will transmit the Loop-back Request for DS2 Channel # 6. NOTE: Whenever the user executes this command, then the Transmit DS3 Framer block will invert the appropriate Cbit of the three (e.g., C71, C72 or C73) based upon the user's setting of Bits 1 and 0 (M23 Loop-back Codes[1:0]) within the DS3 Framer Block - M23 Configuration Register (Address = 0x0E07). BIT 5 - Transmit DS2 Loop-back Request - DS2 Channel 5: See BIT6 description. BIT 4 - Transmit DS2 Loop-back Request - DS2 Channel 4: See BIT6 description. BIT 3 - Transmit DS2 Loop-back Request - DS2 Channel 3: See BIT6 description. BIT 2 - Transmit DS2 Loop-back Request - DS2 Channel 2: See BIT6 description. BIT 1 - Transmit DS2 Loop-back Request - DS2 Channel 1: See BIT6 description. BIT 0 - Transmit DS2 Loop-back Request - DS2 Channel 0: See BIT6 description. 185 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 245: DS3 FRAMER BLOCK - M23 LOOP-BACK ACTIVATION REGISTER (ADDRESS = 0X0E0A) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Remote DS2 Loop-back DS2 Channel 6 Remote DS2 Loop-back DS2 Channel 5 Remote DS2 Loop-back DS2 Channel 4 Remote DS2 Loop-back DS2 Channel 3 Remote DS2 Loop-back DS2 Channel 2 Remote DS2 Loop-back DS2 Channel 1 Remote DS2 Loop-back DS2 Channel 0 R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved BIT6 - Remote DS2 Loop-back - DS2 Channel 6 This READ/WRITE bit-field is used to configure the XRT86SH328 to perform a Remote Loop-back of DS2 Channel 6. If the user configures the XRT86SH328 to perform this loop-back, then the Receive Direction DS2 signal (associated with Channel 6) will internally be looped back into the Transmit Direction. ` 0 - Configures DS2 Channel 6 to operate in the Normal (No Loop-back) Mode ` 1 - Configures DS2 Channel 6 to operate in the Remote Loop-back Mode. Figure 13 presents an illustration of the Functional Block diagram of the XRT86SH328, whenever a given DS2 Channel has been configured to operate in the Remote DS2 Loop-back Mode. FIGURE 13. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN DS2 CHANNEL HAS BEEN CONFIGURED TO OPERATE IN THE REMOTE DS2 LOOP-BACK MODE DS2 Remote Loop-back in DS2 Channel 0 Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface Transmit Transmit DS3 DS3 Framer Framer Block Block M23 M23 MUX MUX Block Block M12 MUX Block Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block From DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT 5 - Remote DS2 Loop-back - DS2 Channel 5 See BIT6 description. 186 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT 4 - Remote DS2 Loop-back - DS2 Channel 4 See BIT6 description. BIT 3 - Remote DS2 Loop-back - DS2 Channel 3 See BIT6 description. BIT 2 - Remote DS2 Loop-back - DS2 Channel 2 See BIT6 description. BIT 1 - Remote DS2 Loop-back - DS2 Channel 1 See BIT6 description. BIT 0 - Remote DS2 Loop-back - DS2 Channel 0 See BIT6 description. TABLE 246: DS3 FRAMER BLOCK - M23 MUX FORCE RECEIVE DS2 AIS COMMAND REGISTERS (ADDRESS = 0X0E0B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Generate DS2 AIS Receive Path - DS2 Channel 7 Generate DS2 AIS Receive Path - DS2 Channel 6 Generate DS2 AIS Receive Path - DS2 Channel 5 Generate DS2 AIS Receive Path - DS2 Channel 4 Generate DS2 AIS Receive Path - DS2 Channel 3 Generate DS2 AIS Receive Path - DS2 Channel 2 Generate DS2 AIS Receive Path -DS2 Channel 1 R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT6 - Generate DS2 AIS Receive Path - DS2 Channel 7 This READ/WRITE bit-field is used to configure the M23 De-MUX block to overwrite the contents of the de-muxed DS2 data-stream (associated with DS2 Channel 7) with the DS2 AIS indicator in the Egress Direction, towards its corresponding (down-stream) M12 De-MUX block. ` 0 - The M23 De-MUX block will transmit normal DS2 data to the down-stream circuitry. ` 1 - The M23 De-MUX block will transmit the DS2 AIS indicator within DS2 Channel 7, within the Egress Direction. Figure 14 presents an illustration of the Functional Block diagram of the XRT86SH328, whenever a given DS2 Channel has been configured to transmit the DS2 AIS indicator in the Egress Direction. 187 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 14. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE M23 DE-MUX HAS BEEN CONFIGURED TO TRANSMIT THE DS2 AIS INDICATOR IN THE EGRESS DIRECTION OF DS2 CHANNEL 0 STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface Transmit Transmit DS3 DS3 Framer Framer Block Block M23 M23 MUX MUX Block Block Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 MUX Block DS2 AIS Pattern M12 De-MUX Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block From DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT 5 - Generate DS2 AIS Receive Path - DS2 Channel 6 See BIT 6 description. BIT 4 - Generate DS2 AIS Receive Path - DS2 Channel 5 See BIT 6 description. BIT 3 - Generate DS2 AIS Receive Path - DS2 Channel 4 See BIT 6 description. BIT 2 - Generate DS2 AIS Receive Path - DS2 Channel 3 See BIT 6 description. BIT 1 - Generate DS2 AIS Receive Path - DS2 Channel 2 See BIT 6 description. BIT 0 - Generate DS2 AIS Receive Path - DS2 Channel 1 See BIT 6 description. 188 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 247: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER (ADDRESS = 0X0E0C) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 PRBS Lock Detect PRBS Receiver Enable PRBS Generator Enable BIT 1 BIT 0 Reserved R/O R/O R/O R/O R/W R/W R/O R/O 0 0 0 0 0 0 0 0 BIT [7:5] - Reserved BIT 4 - PRBS Lock Detect This READ-ONLY bit-field indicates whether or not the PRBS Receiver (within the Receive DS3 Framer block) has acquired PRBS Lock with the payload data of the incoming DS3 data-stream, as described below. ` 0 - Indicates that the PRBS Receiver does not have PRBS Lock with the incoming data-stream. ` 1 - Indicates that the PRBS Receiver does have PRBS Lock with the incoming data-stream. NOTE: This bit-field is only valid if the PRBS Receiver has been enabled. BIT 3 - PRBS Receiver Enable This READ/WRITE bit-field is used to either enable or disable the PRBS Receiver within the Receive DS3 Framer block. Once the user enables the PRBS Receiver, then it will proceed to attempt to acquire and maintain pattern sync (or PRBS Lock) within the payloadbits, within the incoming DS3 data-stream. ` 0 - Disables the PRBS Receiver ` 1 - Enables the PRBS Receiver. BIT 2 - PRBS Generator Enable This READ/WRITE bit-field is used to either enable or disable the PRBS Generator within the Transmit DS3 Framer block. Once the user enables the PRBS Generator block, then it will proceed to insert a PRBS Pattern into the payload bits, within the outbound DS3 data-stream. ` 0 - Disables the PRBS Generator ` 1 - Enables the PRBS Generator. BIT 1 - Receive DS3 Framer By-Pass BIT 0 - Transmit DS3 Framer By-Pass TABLE 248: DS3 FRAMER AND M13 MUX BLOCK - DS3 TEST REGISTER # 2 (ADDRESS = 0X0E0E) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Unused PRBS Type R/O R/W R/W R/W R/O R/O R/O R/W 0 0 0 0 0 0 0 0 BER Control[1:0] BIT 2 BIT 1 Unused BIT 0 Unframed PRBS BIT7 - Unused BIT6 - PRBS Type This READ/WRITE bit-field is used to select between two possible PRBS Patterns, that the PRBS Generator and Receiver will be handling. ` 0 - The PRBS Generator and Receiver will be handling a 2^15-1 PRBS Pattern. ` 1 - The PRBS Generator and Receiver will be handling a 2^23-1 PRBS Pattern. NOTE: This READ/WRITE bit-field is only active if the PRBS Receiver and Generator have been enabled. BIT[5:4] - BER Control[1:0] 189 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 These two READ/WRITE bit-fields are used to select the rate at which the PRBS Generator (within the Transmit DS3 Framer block) will generate and transmit Bit-Errors, within the outbound DS3/PRBS DataStream. The Relationship between the BER Control[1:0] bit-fields and the Resulting Bit Error-Rate that the PRBS Generator will. Insert within the outbound DS3/PRBS data-stream RESULTING BIT ERROR RATE INSERTED WITHIN THE OUTBOUND DS3/PRBS DATA-STREAM BER CONTROL[1:0] 00, 11 No Bit Errors Selected (Normal Operation) 01 1 Bit per 1000 Bits are Erred 10 1 Bit per 1,000,000 Bits are Erred NOTE: These bit-fields are only active if the PRBS Generator has been enabled. BIT[3:1] - Unused BIT 0 - Unframed PRBS This READ/WRITE bit-field is used to configure the PRBS Generator and the Transmit DS3 Framer block to transmit either a Frame or an Unframed PRBS Pattern, within the outbound DS3 data-stream. ` 0 - Configures the PRBS Generator/Transmit DS3 Framer to transmit a Framed PRBS Pattern, whenever the PRBS Generator has been enabled. ` 1 - Configures the PRBS Generator/Transmit DS3 Framer to transmit an Unframed PRBS Pattern, whenever the PRBS Generator has been enabled. NOTE: This bit-field is only active if the PRBS Generator has been enabled. TABLE 249: DS3 FRAMER BLOCK - RECEIVE DS3 CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E10) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS3 AIS Defect Declared DS3 LOS Defect Declared DS3 Idle Pattern Declared DS3 OOF Defect Declared Reserved Framing with Valid P-Bits F Sync Algo M Sync Algo R/O R/O R/O R/O R/O R/W R/W R/W 0 0 0 1 0 1 0 0 BIT7 - DS3 AIS Defect Declared: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the AIS defect condition, within the incoming DS3 data-stream. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the AIS defect condition within the incoming DS3 data-stream. ` 1 - Indicates that the Receive DS3 Framer block is currently declaring the AIS defect condition within the incoming DS3 data-stream. BIT6 - DS3 LOS Defect Declared: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the LOS defect condition, within the incoming DS3 data-stream. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the LOS defect condition within the incoming DS3 data-stream. ` 1 - Indicates that the Receive DS3 Framer block is currently declaring the LOS defect condition within the incoming DS3 data-stream. BIT 5 - DS3 Idle Pattern Declared: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the DS3 Idle 190 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Pattern, within the incoming DS3 data-stream. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the Idle Pattern condition within the incoming DS3 data-stream. ` 1 - Indicates that the Receive DS3 Framer block is currently declaring the Idle Pattern condition within the incoming DS3 data-stream. BIT 4 - DS3 OOF Defect Declared: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the OOF (Outof-Frame) defect condition. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the OOF defect condition. ` 1 - Indicates that the Receive DS3 Framer block is currently declaring the OOF defect condition. BIT 3 - Reserved: BIT 2 - Framing with Valid P-Bits: This READ/WRITE bit-field is used to configure the Receive DS3 Framer block to use either of the following two different sets of DS3 Frame Acquisition/Maintenance criteria. • Normal Framing Acquisition/Maintenance Criteria (without P-bit Checking) In this mode, the Receive DS3 Framer block will declare the In-Frame state, once it has successfully completed both the F-Bit Search and the M-Bit Search states. • Framing Acquisition/Maintenance with P-bit Checking: In this mode, the Receive DS3 Framer block will (in addition to passing through the F-Bit Search and M-Bit Search states) also verify valid P-bits prior to declaring the In-Frame state. ` 0 - Configures the Receive DS3 Framer block to use the Normal Framing Acquisition/Maintenance Criteria (without P-bit Checking) ` 1 - Configures the Receive DS3 Framer block to use the Framing Acquisition/Maintenance with P-Bit Checking criteria. BIT 1 - F-Bit Search State Criteria Select: This READ/WRITE bit-field is used to configure the Receive DS3 Framer block to use either one of the following DS3 Out-of-Frame (OOF) Defect Declaration criteria. ` 0 - Configures the Receive DS3 Framer block to declare the OOF defect condition, whenever it determines that 6 out of the most recent 15 F-bits (within the incoming DS3 data-stream) are erred. ` 1 - Configures the Receive DS3 Framer block to declare the OOF defect condition whenever it determines that 3 out of the most recent 15 F-bits (within the incoming DS3 data-stream) are erred. BIT 0 - M-Bit Search State Criteria: This READ/WRITE bit-field is used to configure the Receive DS3 Framer block to use either one of the following DS3 Out-of-Frame (OOF) Defect Declaration criteria. ` 0 - Configures the Receive DS3 Framer block to NOT declare the OOF defect condition whenever it detects M-bit errors. ` 1 - Configures the Receive DS3 Framer block to declare the OOF defect condition whenever it detects M-bit errors within 3 out of 4 of the most recently received DS3 frames. TABLE 250: DS3 FRAMER BLOCK - RECEIVE DS3 STATUS REGISTER (ADDRESS = 0X0E11) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 DS3 FERF/RDI Defect Declared Received AIC State BIT 2 BIT 1 BIT 0 Received FEBE[2:0] Values R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT7 - 5 - Reserved: 191 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT 4 - DS3 FERF/RDI Defect Declared: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block is currently declaring the FERF/RDI defect condition. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently declaring the FERF/RDI defect condition. ` 1 - Indicates that the Receive DS3 Framer block is currently declaring the FERF/RDI defect condition. BIT 3 - Received AIC State: This READ-ONLY bit-field reflects the current state of the AIC bit-field within the incoming DS3 data-stream. ` 0 - Indicates that the Receive DS3 Framer block has received at least 2 consecutive M-frames that have the AIC bitfield set to 0. ` 1 - Indicates that the Receive DS3 Framer block has received at least 63 consecutive M-frames that have the AIC bitfield set to 1. BIT[2:0] - Received FEBE[2:0] Value: These READ-ONLY bit-fields reflects the FEBE value within the most recently received DS3 frame. ` Received FEBE[2:0] = [1, 1, 1] reflects a normal condition. All other values for Received FEBE[2:0] indicates an erred condition at the remote terminal equipment. NOTE: This bit-field is only active if the Transmit/Receive DS3 Framer blocks have been configured to operate in the C-bit Parity Framing format. TABLE 251: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E12) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Detection of CP-Bit Error Interrupt Enable Change of DS3 LOS Defect Condition Interrupt Enable Change of DS3 AIS Defect Condition Interrupt Enable Change of DS3 Idle Condition Interrupt Enable Change of DS3 FERF/RDID efect Condition Interrupt Enable Change of AIC State Interrupt Enable Change of DS3 OOF Defect Condition Interrupt Enable Detection of P-Bit Error Interrupt Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Detection of CP-Bit Error Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Detection of CP-bit Error interrupt, within the XRT86SH328. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime it detects at least one CP-bit error within the incoming DS3 data-stream. ` 0 - Disables the Detection of CP-Bit Error Interrupt. ` 1 - Enables the Detection of CP-Bit Error Interrupt. NOTE: This bit-field is only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in the C-bit Parity framing format. BIT6 - Change of DS3 LOS Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change in DS3 LOS (Loss of Signal) defect condition, within the XRT86SH328. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in response to either of the following conditions. • The instant that the Receive DS3 Framer block declares the LOS defect condition. • The instant that the Receive DS3 Framer block clears the LOS defect condition. ` 0 - Disables the Change in DS3 LOS Defect Condition Interrupt. ` 1 - Enables the Change in DS3 LOS Defect Condition Interrupt. BIT 5 - Change of DS3 AIS Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change in DS3 AIS (Alarm Indication Signal) defect condition interrupt within the XRT86SH328. If this interrupt is enabled, then the Receive DS3 Framer block will generate 192 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS an interrupt in response to either of the following events. • The instant that the Receive DS3 Framer block declares the AIS defect condition. • The instant that the Receive DS3 Framer block clears the AIS defect condition. ` 0 - Disables the Change in AIS Defect Condition interrupt. ` 1 - Enables the Change in DS3 AIS Defect Condition Interrupt. BIT 4 - Change of DS3 Idle Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change in DS3 Idle Condition interrupt, within the Receive DS3 Framer block. If the user enables this interrupt then the Receive DS3 Framer block will generate an interrupt in response to either of the following conditions. • The instant that the Receive DS3 Framer block detects and declares the DS3 Idle condition. • The instant that the Receive DS3 Framer block clears the DS3 Idle condition. ` 0 - Disables the Change in DS3 Idle Condition Interrupt. ` 1 - Enables the Change in DS3 Idle Condition Interrupt. BIT 3 - Change of DS3 FERF/RDI Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change in DS3 FERF/RDI Defect Condition Interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in response to either of the following condition. • The instant that the Receive DS3 Framer block declares the FERF/RDI defect condition. • The instant that the Receive DS3 Framer block clears the FERF/RDI defect condition. ` 0 - Disables the Change in DS3 FERF/RDI Defect Condition Interrupt. ` 1 - Enables the Change in DS3 FERF/RDI Defect Condition Interrupt. BIT 2 - Change of AIC State Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change in AIC State interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in response to it detecting a change in the AIC bit-field, within the incoming DS3 data-stream. ` 0 - Disables the Change of AIC State Interrupt. ` 1 - Enables the Change of AIC State Interrupt. BIT 1 - Change of DS3 OOF Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of DS3 OOF Defect Condition Interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt in response to either of the following conditions. • The instant that the Receive DS3 Framer block declares the DS3 OOF Defect Condition. • The instant that the Receive DS3 Framer block cleares the DS3 OOF Defect Condition. ` 0 - Disables the Change in DS3 OOF Defect Condition Interrupt. ` 1 - Enables the Change in DS3 OOF Defect Condition Interrupt. BIT 0 - Detection of P-Bit Error Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Detection of P-Bit Error Interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime it detects P-bit errors within the incoming DS3 data-stream. ` 0 - Disables the Detection of P-Bit Error Interrupt ` 1 - Enables the Detection of P-Bit Error Interrupt 193 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 252: DS3 FRAMER BLOCK - RECEIVE DS3 INTERRUPT STATUS REGISTER (ADDRESS = 0X0E13) BIT7 Detection of CP-Bit Error Interrupt Status BIT6 BIT 5 Change of Change of DS3 LOS DS3 AIS Defect Defect Condition Condition Interrupt Sta- Interrupt Status tus BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of DS3 Idle Condition Interrupt Status Change of DS3 FERF/RDID efect Condition Interrupt Status Change of AIC State Interrupt Status Change of DS3 OOF Defect Condition Interrupt Status Detection of P-Bit Error Interrupt Status RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT7 - Detection of CP-Bit Error Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Detection of CP-Bit Error Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Detection of CP-Bit Error Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of CP-Bit Error Interrupt has occurred since the last read of this register. NOTE: This bit-field is only active if the Transmit and Receive DS3 Framer block are configured to operate in the C-Bit Parity Framing Format. BIT6 - Change of DS3 LOS Defect Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change in DS3 LOS Defect Condition Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Change in DS3 LOS Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in DS3 LOS Defect Condition Interrupt has occurred since the last read of this register. BIT 5 - Change of DS3 AIS Defect Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change of DS3 AIS Defect Condition Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Change of DS3 AIS Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS3 AIS Defect Condition Interrupt has occurred since the last read of this register. BIT 4 - Change of DS3 Idle Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change in DS3 Idle Condition interrupt has occurred since the last read of this register. ` 0 - Indicates that the Change of DS3 Idle Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS3 Idle Condition Interrupt has occurred since the last read of this register. BIT 3 - Change of DS3 FERF/RDI Defect Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change of DS3 FERF/RDI Defect Condition Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Change of DS3 FERF/RDI Defect Condition interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change in DS3 FERF/RDI Defect Condition interrupt has occurred since the last read of this register. BIT 2 - Change of AIC State Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change in AIC State Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Change in AIC State interrupt has NOT occurred since the last read of this register. 194 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 1 - Indicates that the Change in AIC State Interrupt has occurred since the last read of this register. BIT 1 - Change of DS3 OOF Defect Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change in DS3 OOF Defect Condition interrupt has occurred since the last read of this register. ` 0 - Indicates that the Change of DS3 OOF Defect Condition Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS3 OOF Defect Condition Interrupt has occurred since the last read of this register. BIT 0 - Detection of P-Bit Error Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Detection of P-Bit Error Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Detection of P-Bit Error Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Detection of P-Bit Error Interrupt has occurred since the last read of this register. TABLE 253: DS3 FRAMER BLOCK - RECEIVE DS3 SYNC DETECT REGISTER (ADDRESS = 0X0E14) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 F - Sync Algorithm One and Only R/O R/O R/O R/O R/O R/W R/W R/W 0 0 0 0 0 0 0 0 BIT[7:2] - Reserved: BIT 1 - F-Sync Algorithm This READ/WRITE bit-field is used to select the F-bit acquisition criteria when the Receive DS3 Framer block is operating in the F-Bit Search state. ` 0 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, when it has properly located 10 consecutive F-bits. ` 1 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, when it has properly located 16 consecutive F-bits. BIT 0 - One and Only: This READ/WRITE bit-field is used to select the F-bit acquisition criteria that the Receive DS3 Framer block will use, whenever it is operating in the F-Bit Search state, as described below. ` 0 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, whenever it has properly located 10 (or 16) consecutive F-bits (as configured in BIT 1 of this register). ` 1 - Configures the Receive DS3 Framer block to move onto the M-Bit Search state, whenever (1) it has properly located 10 (or 16) consecutive F-bits and (2) when it has located and identified only one viable F-Bit Alignment candidate. NOTE: If this bit is set to 1, then the Receive DS3 Framer block will NOT transition into the M-Bit Search state as long as at least two viable candidate sets of bits appears to function as the F-bits. TABLE 254: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC REGISTER (ADDRESS = 0X0E16) BIT7 BIT6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 RxFEAC_Code[5:0] BIT 0 Unused R/O R/O R/O R/O R/O R/O R/O R/O 0 1 1 1 1 1 1 0 BIT7 - Unused: BIT[6:1] - Receive FEAC Code[5:0]: 195 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 These READ-ONLY bit-fields contain the value of the most recently validated FEAC Code word. NOTE: These register bits are only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in the C-bit Parity Framing format. BIT 0 - Unused: TABLE 255: DS3 FRAMER BLOCK - RECEIVE DS3 FEAC INTERRUPT ENABLE/STATUS REGISTER (ADDRESS = 0X0E17) BIT7 BIT6 BIT 5 Set to [0, 0, 0] BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FEAC Valid Receive FEAC Removal Interrupt Enable Receive FEAC Removal Interrupt Status Receive FEAC Valid Interrupt Enable Receive FEAC Valid Interrupt Status R/W R/W R/W R/O R/W RUR R/W RUR 0 0 0 0 0 0 0 0 Bits 7 - 5 - Set to [0, 0, 0]: ` Please set these three bit-fields to 0 (the default value) for normal operation. BIT 4 - FEAC Message Valid: This READ-ONLY bit-field indicates that the FEAC Code word (which resides within the Receive DS3 FEAC Register) has been validated by the Receive FEAC Controller block. The Receive FEAC Controller block will validate a FEAC Codeword if it has received this same codeword in 8 out of the last 10 FEAC Messages. Polled systems can monitor this bit-field when checking for a newly validated FEAC Codeword. ` 0 - Indicates that the FEAC Message (residing in the Receive DS3 FEAC register) is no longer validated. ` 1 - Indicates that the FEAC Message (residing in the Receive DS3 FEAC register) has been validated. BIT 3 - Receive FEAC Removal Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Receive FEAC Message Removal interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime the most recently validated FEAC Message has been removed. The Receive FEAC Controller will remove a validated FEAC codeword, if it has received a different codeword in 3 out of the last 10 FEAC Messages. ` 0 - Disables the Receive FEAC Message Removal Interrupt. ` 1 - Enables the Receive FEAC Message Removal Interrupt. BIT 2 - Receive FEAC Removal Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Receive FEAC Message Removal Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Receive FEAC Message Removal Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Receive FEAC Message Removal Interrupt has occurred since the last read of this register. BIT 1 - Receive FEAC Valid Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Receive FEAC Message Validation Interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime the Receive FEAC Controller block has validated a new FEAC Code word. ` 0 - Disables the Receive FEAC Message Validation Interrupt. ` 1 - Enables the Receive FEAC Message Validation Interrupt. BIT 0 - Receive FEAC Valid Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Receive FEAC Message Validation Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Receive FEAC Message Validation Interrupt has NOT occurred since the last read of this 196 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS register. ` 1 - Indicates that the Receive FEAC Message Validation Interrupt has occurred since the last read of this register. TABLE 256: DS3 FRAMER BLOCK - RECEIVE LAPD CONTROL REGISTER (ADDRESS = 0X0E18) BIT7 BIT6 BIT 5 Receive Any Kind of LAPD Message BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 Receive LAPD Controller Block Enable Receive LAPD Message Interrupt Enable Receive LAPD Message Interrupt Status R/W R/O R/O R/O R/O R/W R/W RUR 0 0 0 0 0 0 0 0 BIT7 - Receive Any Kind of LAPD Message: This READ/WRITE bit-field is used to configure the Receive LAPD Controller block to receive any kind of LAPD Message (or HDLC Message) with a size of 82 bytes or less. If the user implements this option, then the Receive LAPD Controller block will be capable of receiving any kind of HDLC Message (with any value the header bytes). The only restriction is that the size of the HDLC Message must not exceed 82 bytes. ` 0 - Does not invoke the Any Kind of HDLC Message feature. In this case, the Receive LAPD Controller block will only receive HDLC Messages that contains the Bellcore GR-499CORE values for SAPI and TEI. ` 1 - Invokes this Any Kind of HDLC Message feature. In this case, the Receive LAPD Controller block will be able to receive HDLC Messages that contains any header byte values. NOTE: The user can determine the size (or byte count) of the most recently received LAPD/PMDL Message by reading the contents of the Receive LAPD Byte Count Register (Address = 0x0E84). BIT[6:3] - Unused: BIT 2 - Receive LAPD Controller Block Enable: This READ/WRITE bit-field is used to either enable or disable the Receive LAPD Controller block within the Receive DS3 Framer block. If the user enables the Receive LAPD Controller block, then it will immediately begin extracting out and monitoring the data (being carried via the DL bits) within the incoming DS3 data-stream. ` 0 - Disables the Receive LAPD Controller block. ` 1 - Enables the Receive LAPD Controller block. BIT 1 - Receive LAPD Message Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Receive LAPD Message Interrupt. If this interrupt is enabled, then the Receive DS3 Framer block will generate an interrupt anytime the Receive LAPD Controller block receives a new PMDL Message. ` 0 - Disables the Receive LAPD Message Interrupt. ` 1 - Enables the Receive LAPD Message Interrupt. BIT 0 - Receive LAPD Message Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Receive LAPD Message Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Receive LAPD Message Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Receive LAPD Message' Interrupt has occurred since the last read of this register. 197 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 257: DS3 FRAMER BLOCK - RECEIVE DS3 LAPD STATUS REGISTER (ADDRESS = 0X0E19) BIT7 BIT6 BIT 5 Unused Receive ABORT R/O R/O R/O 0 0 0 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive C/R Type Receive LAPD FCS Error Detected End of Message Flag Sequence Present R/O R/O R/O R/O R/O 0 0 0 0 0 RxLAPD_Msg_Type[1:0] BIT7 - Unused: BIT6 - Receive ABORT: This READ-ONLY bit-field indicates that the Receive LAPD Controller block has received an ABORT sequence (e.g., a string of seven consecutive 0s) within the incoming data-stream. ` 0 - Indicates that the Receive LAPD Controller block has NOT received an ABORT sequence. ` 1 - Indicates that the Receive LAPD Controller block has received an ABORT sequence. NOTE: Once the Receive LAPD Controller block receives an ABORT Sequence, it will set this bit-field high until it receives another LAPD Message. BIT[5:4] - Receive LAPD Message Type[1:0]: These two READ-ONLY bit-fields indicate the type of LAPD Message that is residing within the Receive LAPD Message Buffer. The relationship between the contents of these two bit-fields and the corresponding message type is presented below. Message Type RECEIVE LAPD MESSAGE TYPE[1:0] MESSAGE TYPE 0 0 CL Path Identification 0 1 Idle Signal Identification 1 0 Test Signal Identification 1 1 ITU-T Path Identification BIT 3 - Receive C/R Type: This READ-ONLY bit-field indicates the value of the C/R bit-field (within one of the header bytes) of the most recently received LAPD Message. BIT 2 - Receive LAPD FCS Error Detected: This READ-ONLY bit-field indicates whether or not the most recently received LAPD Message frame contained an FCS error or not. ` 0 - Indicates that the most recently received LAPD Message frame does not contain an FCS error. ` 1 - Indicates that the most recently received LAPD Message frame does contain an FCS error. BIT 1 - End of Message: This READ-ONLY bit-field indicates whether or not the Receive LAPD Controller block has received a complete LAPD Message. ` 0 - Indicates that the Receive LAPD Controller block is currently receiving a LAPD Message, but has not received the complete message. ` 1 - Indicates that the Receive LAPD Controller block has received a complete LAPD Message. NOTE: Once the Receive LAPD Controller block sets this bit-field high, this bit-field will remain high until the Receive LAPD Controller block begins to receive a new LAPD Message. BIT 0 - Flag Sequence Present: 198 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This READ-ONLY bit-field indicates whether or not the Receive LAPD Controller block is currently receiving the Flag Sequence (e.g., a continuous stream of 0x7E octets within the Data Link channel). ` 0 - Indicates that the Receive LAPD Controller block is NOT currently receiving the Flag Sequence octet within the incoming Data Link channel. ` 1 - Indicates that the Receive LAPD Controller block is currently receiving a continuous stream of Flag Sequence octets within the incoming Data Link channel. TABLE 258: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E1A) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7, 5 - Reserved BIT 4 - Set G.747 Mode This READ/WRITE bit-field is used to configure the M12 MUX and De-MUX (associated with DS2 Channel # 1) to operate in either the DS2 or the G.747 Mode. If the user configures the M12 MUX and De-MUX to operate in the DS2 Mode, then all of the following will be true. • The M12 MUX will multiplex four (4) DS1 signals into a DS2 signal, prior to routing it to the M23 MUX. • The M12 De-MUX will accept a DS2 data-stream (from the M23 De-MUX) and it will de-multiplex this datastream into four (4) DS1 signals (prior to being output to the Egress Direction Receive DS1/E1 Framer block). Likewise, if the user configures the M12 MUX and De-MUX to operate in the G.747 Mode, then all of the following will be true. • The M12 MUX will multiplex three (3) E1 signals into a G.747 data-stream, prior to routing it to the M23 MUX • The M12 De-MUX will accept a G.747 data-stream (from the M23 De-MUX) and it will de-multiplex this datastream into three (3) E1 signals (prior to being output to the Egress Direction Receive DS1/E1 Framer block). ` 0 - Configures the M12 MUX (associated with DS2 Channel # 1) to operate in the DS2 Mode. ` 1 - Configures the M12 MUX (associated with DS2 Channel # 1) to operate in the G.747 Mode. BIT 3 - Set G.747 Reserved Bit This READ/WRITE bit-field is used to configure M12 MUX to set the Reserved bit (within a G.747 data-stream) to either a 0 or 1. ` 0 - Configures the M12 MUX to set the G.747 Reserved bit (within the outbound G.747 data-stream) to 0. ` 1 - Configures the M12 MUX to set the G.747 Reserved bit (within the outbound G.747 data-stream) to 1. NOTE: This bit-field is only active if the M12 MUX/De-MUX has been configured to operate in the G.747 Mode. BIT 2 - Set M12 FERF Bit Value Bits 1, 0 - M12 Loop-back Code[1:0]: These READ/WRITE bit-fields are used to specify the coding (or the values that the M12 MUX block will set the C-bits, within its outbound DS2 data-stream to) in order to request that the remote terminal equipment operate in the remote DS1 Loop-back Mode. 199 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Loop-Back Codes M12 LOOP-BACK CODES[1:0] C-BIT SETTINGS TO REQUEST DS2 LOOP-BACK CODES 00/11 Cj1 = Cj2 = Cj3* The M12 MUX block will invert the state of the Cj3 bit (from that of the corresponding Cj1 and Cj2 bits) within the outbound DS2 signal in order to request that the remote terminal execute a remote Loop-back within the jth DS1 signal. 01 Cj1 = Cj2* = Cj3 The M12 MUX block will insert the state of the of the Cj2 bit (from that of the corresponding Cj1 and Cj3 bits) within the outbound DS2 signal in order to request that the remote terminal execute a remote Loop-back within the jth DS1 signal. 10 Cj1* = Cj2 = Cj3 The M12 MUX block will invert the state of the Cj1 bit (from that of the corresponding Cj2 and Cj3 bits) in order to request that the remote terminal execute a remote Loop-back within the jth DS1 signal. COMMENTS NOTE: Anytime the M12 MUX block has been configured to transmit a DS2 Loop-back request code, then it will set the C-bits to the appropriate value (based upon the user-selection) as specified in the above table. TABLE 259: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E1B) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 2 for Channel 1. TABLE 260: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E1C) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 3 for Channel 1. TABLE 261: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E1D) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 4 for Channel 1. 200 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 262: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E1E) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 5 for Channel 1. TABLE 263: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E1F) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 6 for Channel 1. TABLE 264: DS3 FRAMER BLOCK - M12 CONFIGURATION REGISTER - DS2 CHANNEL # 7 (ADDRESS = 0X0E20) BIT7 BIT6 BIT 5 Reserved BIT 4 BIT 3 BIT 2 Set G.747 Mode Set G.747 Reserved Bit M12 FERF Bit Setting BIT 1 BIT 0 M12 Loop-back Code[1:0] R/O R/O R/O R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 258 above, for Bit descriptions, substituting Channel 7 for Channel 1. TABLE 265: DS3 FRAMER BLOCK - M12 DE-MUX FORCE DS1/E1 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E21) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 4 Force Receive DS1/E1 AIS - DS1/E1 Channel 3 Force Receive DS1/E1 AIS - DS1/E1 Channel 2 Force Receive DS1/E1 AIS - DS1/E1 Channel 1 Force Transmit DS1/E1 AIS - DS1/E1 Channel 4 Force Transmit DS1/E1 AIS - DS1/E1 Channel 3 Force Transmit DS1/E1 AIS - DS1/E1 Channel 2 Force Transmit DS1/E1 AIS - DS1/E1 Channel 1 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Force Receive DS1/E1 AIS - DS1/E1 Channel 4 This READ/WRITE bit-field is used to force the M12 De-MUX Block (associated with DS2 Channel # 0) to overwrite the Egress Direction or De-Multiplexed DS1/E1 Signal associated with DS1/E1 Channel 4, with a DS1/E1 AIS Pattern as it is de-muxing this DS1/E1 signal from the incoming DS2 data-stream, as described below. ` 0 - Configures the M12 De-MUX block to NOT transmit the DS1/E1 AIS Pattern, via Egress Direction DS1/E1 Channel 4. ` 1 - Configures the M12 De-MUX block to transmit the DS1/E1 AIS Pattern, via Egress Direction DS1/E1 Channel 4. 201 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Figure 15 presents an illustration of the Functional Block diagram of the XRT86SH328, whenever a given M12 De-MUX block has been configured to transmit the DS1/E1 AIS indicator (within a given DS1/E1 signal) in the Egress Direction. NOTE: For normal operation, the user MUST set this bit-field to 0. FIGURE 15. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER A GIVEN M12 DE-MUX BLOCK HAS BEEN CONFIGURED TO TRANSMIT THE DS1/E1 AIS INDICATOR (WITHIN A GIVEN DS1/E1 SIGNAL) IN THE EGRESS DIRECTION STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block DS1/E1 AIS in Egress Direction To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block From DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT6 - Force Receive DS1/E1 AIS - DS1/E1 Channel 3 See Description of BIT7. BIT 5 - Force Receive DS1/E1 AIS - DS1/E1 Channel 2 See Description of BIT7. BIT 4 - Force Receive DS1/E1 AIS - DS1/E1 Channel 1 See Description of BIT7. BIT 3 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 4 This READ/WRITE bit-field is used to force the M12 MUX Block (associated with DS2 Channel # 0) to overwrite the Ingress Direction DS1/E1 Signal (associated with DS1/E1 Channel 4, with a DS1/E1 AIS Pattern. If the user invoke this feature, then the M12 MUX Block will transmit a DS1/E1 AIS pattern (within DS1/E1 Channel 4) towards the M23 MUX Block. ` 0 - Configures the M12 MUX Block to NOT transmit the DS1/E1 AIS Pattern, via the Ingress Direction DS1/E1 Channel 3. ` 1 - Configures the M12 MUX Block to transmit the DS1/E1 AIS Pattern, via the Ingress Direction DS1/E1 Channel 3. NOTE: For normal operation, the user MUST set this bit-field to 0. BIT 2 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 3 See description of BIT 3. BIT 1 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 2 202 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS See description of BIT 3. BIT 0 - Force Transmit DS1/E1 AIS - DS1/E1 Channel 1 See description of BIT 3. TABLE 266: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 1 (ADDRESS = 0X0E22) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 7 Force Receive DS1/E1 AIS - DS1/E1 Channel 6 Force Receive DS1/E1 AIS - DS1/E1 Channel 5 Force Receive DS1/E1 AIS - DS1/E1 Channel 4 Force Transmit DS1/E1 AIS - DS1/E1 Channel 7 Force Transmit DS1/E1 AIS - DS1/E1 Channel 6 Force Transmit DS1/E1 AIS - DS1/E1 Channel 5 Force Transmit DS1/E1 AIS - DS1/E1 Channel 4 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 1 for DS2 Channel 0 and Receive TABLE 267: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 2 (ADDRESS = 0X0E23) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 11 Force Receive DS1/E1 AIS - DS1/E1 Channel 10 Force Receive DS1/E1 AIS - DS1/E1 Channel 9 Force Receive DS1/E1 AIS - DS1/E1 Channel 8 Force Transmit DS1/E1 AIS - DS1/E1 Channel 11 Force Transmit DS1/E1 AIS - DS1/E1 Channel 10 Force Transmit DS1/E1 AIS - DS1/E1 Channel 9 Force Transmit DS1/E1 AIS - DS1/E1 Channel 8 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 2 for DS2 Channel 0 and Receive TABLE 268: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 3 (ADDRESS = 0X0E24) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 15 Force Receive DS1/E1 AIS - DS1/E1 Channel 14 Force Receive DS1/E1 AIS - DS1/E1 Channel 13 Force Receive DS1/E1 AIS - DS1/E1 Channel 12 Force Transmit DS1/E1 AIS - DS1/E1 Channel 15 Force Transmit DS1/E1 AIS - DS1/E1 Channel 14 Force Transmit DS1/E1 AIS - DS1/E1 Channel 13 Force Transmit DS1/E1 AIS - DS1/E1 Channel 12 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 3 for DS2 Channel 0 and Receive DS1/E1 AIS - DS1/E1 Channel [15:12] Receive DS1/E1 AIS - DS1/E1 Channel [3:0]. 203 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 269: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 4 (ADDRESS = 0X0E25) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 19 Force Receive DS1/E1 AIS - DS1/E1 Channel 18 Force Receive DS1/E1 AIS - DS1/E1 Channel 17 Force Receive DS1/E1 AIS - DS1/E1 Channel 16 Force Transmit DS1/E1 AIS - DS1/E1 Channel 19 Force Transmit DS1/E1 AIS - DS1/E1 Channel 18 Force Transmit DS1/E1 AIS - DS1/E1 Channel 17 Force Transmit DS1/E1 AIS - DS1/E1 Channel 16 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 4 for DS2 Channel 0 and Receive DS1/E1 AIS - DS1/E1 Channel [19:16] Receive DS1/E1 AIS - DS1/E1 Channel [3:0]. TABLE 270: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 5 (ADDRESS = 0X0E26) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 23 Force Receive DS1/E1 AIS - DS1/E1 Channel 22 Force Receive DS1/E1 AIS - DS1/E1 Channel 21 Force Receive DS1/E1 AIS - DS1/E1 Channel 20 Force Transmit DS1/E1 AIS - DS1/E1 Channel 23 Force Transmit DS1/E1 AIS - DS1/E1 Channel 22 Force Transmit DS1/E1 AIS - DS1/E1 Channel 21 Force Transmit DS1/E1 AIS - DS1/E1 Channel 20 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 5 for DS2 Channel 0 and Receive DS1/E1 AIS - DS1/E1 Channel [23:20] Receive DS1/E1 AIS - DS1/E1 Channel [3:0]. TABLE 271: DS3 FRAMER BLOCK - M12 AIS REGISTER - DS2 CHANNEL # 6 (ADDRESS = 0X0E27) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force Receive DS1/E1 AIS - DS1/E1 Channel 27 Force Receive DS1/E1 AIS - DS1/E1 Channel 26 Force Receive DS1/E1 AIS - DS1/E1 Channel 25 Force Receive DS1/E1 AIS - DS1/E1 Channel 21 Force Transmit DS1/E1 AIS - DS1/E1 Channel 27 Force Transmit DS1/E1 AIS - DS1/E1 Channel 26 Force Transmit DS1/E1 AIS - DS1/E1 Channel 25 Force Transmit DS1/E1 AIS - DS1/E1 Channel 24 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Figure 265 above, for Bit descriptions, substituting DS2 Channel 5 for DS2 Channel 0 and Receive DS1/E1 AIS - DS1/E1 Channel [27:21] Receive DS1/E1 AIS - DS1/E1 Channel [3:0]. 204 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 272: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 1 (ADDRESS = 0X0E28) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 3 M12 Remote Loop-Back Mode - DS1 Channel 2 M12 Remote Loop-Back Mode - DS1 Channel 1 M12 Remote Loop-Back Mode - DS1 Channel 0 M12 LoopBack Request DS1 Channel 3 M12 LoopBack Request DS1 Channel 2 M12 LoopBack Request DS1 Channel 1 M12 LoopBack Request DS1 Channel 0 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - M12 Remote Loop-Back Mode - DS1 Channel 3 This READ/WRITE bit-field is used to configure DS1 Channel 3 to operate in the M12 Remote Loop-back Mode. If the user configures DS1 Channel 3 to operate in the M12 Remote Loop-back Mode, then the Egress Direction DS1 Channel 3 signal (as it is de-multiplexed from the DS2 signal by the M12 De-MUX block) will be internally looped back into the Ingress Direction (back towards the M12 MUX block). ` 0 - Configures DS1 Channel 3 to NOT operate in the M12 Remote Loop-back Mode (Normal Operation) ` 1 - Configures DS1 Channel 3 to operate in the M12 Remote Loop-back Mode. Figure 16 presents an illustration of the Functional Block Diagram of the XRT86SH328, whenever it has been configured to operate in the M12 Remote Loop-back Mode. FIGURE 16. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER IT HAS BEEN CONFIGURED TO OPERATE IN THE M12 REMOTE LOOP-BACK MODE STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface Transmit Transmit DS3 DS3 Framer Framer Block Block M23 M23 MUX MUX Block Block Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 MUX Block M12 Remote Loop-back Path DS2 Channel 0 M12 De-MUX Block DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT6 - M12 Remote Loop-Back Mode - DS1 Channel 2 See description of BIT7. BIT 5 - M12 Remote Loop-Back Mode - DS1 Channel 1 205 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 See description of BIT7. BIT 4 - M12 Remote Loop-Back Mode - DS1 Channel 0 See description of BIT7. BIT 3 - M12 Loop-back Request - DS1 Channel 3 This READ/WRITE bit-field is used to command the M12 MUX block to transmit the Loop-back Request indicator for DS1 Channel 3. ` 0 - The M12 MUX block will NOT transmit the Loop-back Request for DS1 Channel 3 (Normal Operation). ` 1 - The M12 MUX block will transmit the Loop-back Request for DS1 Channel 3. NOTE: Whenever the user executes this command, then the M12 MUX Block (associated with DS2 Channel # 0) will invert the appropriate C-bits of the three (e.g., C41, C42 or C43) within the outbound DS2 data-stream based upon the user's settings of Bits 1 and 0 (M12 Loop-back Codes[1:0]) within the DS3 Framer Block - M12 Configuration Register - DS2 Channel # 0 (Address = 0x0E1A). BIT 2 - M12 Loop-back Request - DS1 Channel 2 See description of BIT 3. BIT 1 - M12 Loop-back Request - DS1 Channel 1 See description of BIT 3. BIT 0 - M12 Loop-back Request - DS1 Channel 0 See description of BIT 3. TABLE 273: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 2 (ADDRESS = 0X0E29) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 7 M12 Remote Loop-Back Mode - DS1 Channel 6 M12 Remote Loop-Back Mode - DS1 Channel 5 M12 Remote Loop-Back Mode - DS1 Channel 4 M12 LoopBack Request DS1 Channel 7 M12 LoopBack Request DS1 Channel 6 M12 LoopBack Request DS1 Channel 5 M12 LoopBack Request DS1 Channel 4 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [7:4] for Channel [3:0}. TABLE 274: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 3 (ADDRESS = 0X0E2A) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 11 M12 Remote Loop-Back Mode - DS1 Channel 10 M12 Remote Loop-Back Mode - DS1 Channel 9 M12 Remote Loop-Back Mode - DS1 Channel 8 M12 LoopBack Request DS1 Channel 11 M12 LoopBack Request DS1 Channel 10 M12 LoopBack Request DS1 Channel 9 M12 LoopBack Request DS1 Channel 8 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [11:8] for Channel [3:0}. 206 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 275: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 4 (ADDRESS = 0X0E2B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 15 M12 Remote Loop-Back Mode - DS1 Channel 14 M12 Remote Loop-Back Mode - DS1 Channel 13 M12 Remote Loop-Back Mode - DS1 Channel 12 M12 LoopBack Request DS1 Channel 15 M12 LoopBack Request DS1 Channel 14 M12 LoopBack Request DS1 Channel 13 M12 LoopBack Request DS1 Channel 12 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [15:12] for Channel [3:0}. TABLE 276: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 5 (ADDRESS = 0X0E2C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 19 M12 Remote Loop-Back Mode - DS1 Channel 18 M12 Remote Loop-Back Mode - DS1 Channel 17 M12 Remote Loop-Back Mode - DS1 Channel 16 M12 LoopBack Request DS1 Channel 19 M12 LoopBack Request DS1 Channel 18 M12 LoopBack Request DS1 Channel 17 M12 LoopBack Request DS1 Channel 16 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [19:16] for Channel [3:0}. TABLE 277: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 6 (ADDRESS = 0X0E2D) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 23 M12 Remote Loop-Back Mode - DS1 Channel 22 M12 Remote Loop-Back Mode - DS1 Channel 21 M12 Remote Loop-Back Mode - DS1 Channel 20 M12 LoopBack Request DS1 Channel 23 M12 LoopBack Request DS1 Channel 22 M12 LoopBack Request DS1 Channel 21 M12 LoopBack Request DS1 Channel 20 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [23:20] for Channel [3:0}. TABLE 278: DS3 FRAMER BLOCK - M12 LOOP-BACK REGISTER - 7 (ADDRESS = 0X0E2E) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 M12 Remote Loop Back Mode - DS1 Channel 27 M12 Remote Loop-Back Mode - DS1 Channel 26 M12 Remote Loop-Back Mode - DS1 Channel 25 M12 Remote Loop-Back Mode - DS1 Channel 24 M12 LoopBack Request DS1 Channel 27 M12 LoopBack Request DS1 Channel 26 M12 LoopBack Request DS1 Channel 25 M12 LoopBack Request DS1 Channel 24 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 207 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT [7:0] See Table 272 above for bit descriptions, substituting Channel [27:24] for Channel [3:0}. TABLE 279: DS3 FRAMER BLOCK - TRANSMIT DS3 CONFIGURATION REGISTER (ADDRESS = 0X0E30) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Force DS3 Tx FERF/RDI Force X-Bits to 1 Transmit DS3 Idle Signal Transmit AIS Indicator Transmit LOS Indicator Transmit FERF/RDI upon LOS Transmit FERF/RDI upon LOF Transmit FERF/RDI upon AIS R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 1 1 1 BIT7 - Force Transmit DS3 FERF/RDI Indicator This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the FERF/RDI indicator to the remote terminal equipment by setting both of the X-bits (within each outbound DS3 frame) to 0. ` 0 - Does not force the Transmit DS3 Framer block to transmit the DS3 FERF/RDI indicator. In this case, the Transmit DS3 Framer block will set the X bits (within each outbound DS3 frame) to the appropriate value, depending upon receive conditions (as detected by the Receive DS3 Framer block). ` 1 - Forces the Transmit DS3 Framer block to transmit the DS3 FERF/RDI indicator. In this case, the Transmit DS3 Framer block will force the X bits (within each outbound DS3 frame) to 0. NOTE: For normal operation (e.g., where the Transmit DS3 Framer Block will automatically transmit the FERF/RDI indicator whenever the Receive DS3 Framer block declares either the LOS, AIS or LOF/OOF defect conditions) the user MUST set this bit-field to 0. BIT6 - Force X-Bits to 1 This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to set the X-bits (within each outbound DS3 frame) to 1. ` 0 - Configures the Transmit DS3 Framer block to automatically set the X bits to the appropriate value, depending upon the receive conditions (as detected by the Receive DS3 Framer block). ` 1 - Configures the Transmit DS3 Framer block to force all of the X bits (within the outbound DS3 data-stream) to 1. In this configuration setting, the Transmit DS3 Framer block will set all X bits to 1 independent of whether the Receive DS3 Framer block is currently declaring any defect conditions. NOTE: For normal operation (e.g., where the Transmit DS3 Framer block will automatically transmit the FERF/RDI indicator whenever the Receive DS3 Framer block declares the LOS, AIS or LOF/OOF defect condition) the user MUST set this bit-field to 0. BIT 5 - Transmit DS3 Idle Signal This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the DS3 Idle Signal pattern to the remote terminal equipment, as described below. ` 0 - Configures the Transmit DS3 Framer block to transmit normal traffic to the remote terminal equipment. ` 1 - Configures the Transmit DS3 Framer block to transmit the DS3 Idle Pattern to the remote terminal equipment. NOTES: 1. This bit-field is ignored if Bits 3 (Transmit LOS Indicator) or 4 (Transmit AIS Indicator) are set to 1. 2. The exact pattern that the Transmit DS3 Framer block will transmit (whenever this bit-field is set to 1) depends upon the contents within Bits 3 through 0 (Transmit DS3 Idle Pattern[3:0]) within the DS3 Framer Block - Transmit DS3 Pattern Register (Address = 0x0E4C). BIT 4 - Transmit AIS Indicator This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the DS3 AIS indicator to the remote terminal equipment as described below. ` 0 - Configures the Transmit DS3 Framer block to transmit normal traffic (based upon T1/E1 data that has been multiplexed into a DS3 data-stream) to the remote terminal equipment. ` 1 - Configures the Transmit DS3 Framer block to transmit the DS3 AIS indicator to the remote terminal equipment. NOTES: 208 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS 1. This bit-field is ignored if BIT 3 (Transmit LOS Indicator) is set to 1. 2. Whenever this bit-field is set to 1, the Transmit DS3 Framer block will either transmit a Framed repeating 1, 0, 1, 0, …. Pattern, or an Unframed All Ones pattern, depending upon the state of BIT7 (Transmit AIS Unframed All Ones), within the Transmit DS3 Pattern Register (Address = 0x0E4C). BIT 3 - Transmit LOS Indicator This READ/WRITE bit-field is used to force the Transmit DS3 Framer block to transmit the LOS pattern to the remote terminal equipment, as described below. ` 0 - Configures the Transmit DS3 Framer block to transmit normal traffic to the remote terminal equipment. ` 1 - Configures the Transmit DS3 Framer block to transmit the LOS pattern (e.g., either an All Zeros or All Ones pattern, depending upon user configuration). NOTE: Whenever this bit-field is set to 1, it will transmit either an All Zero pattern or an Unframed All Ones pattern, depending upon the state of BIT 4 (Transmit LOS Pattern - All Ones Pattern) within the Transmit DS3 Pattern Register (Address = 0x0E4C). BIT 2 - Transmit FERF/RDI upon LOS This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, anytime (and for the duration that) the Receive DS3 Framer block declares the LOS defect condition. ` 0 - Configures the Transmit DS3 Framer block to NOT automatically transmit the FERF/RDI indicator, whenever (and for the duration that) the Receive DS3 Framer block declares the LOS defect condition. ` 1 - Configures the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, whenever (and for the duration that) the Receive DS3 Framer block declares the LOS defect condition. BIT 1 - Transmit FERF/RDI upon LOF/OOF: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, anytime (and for the duration that) the Receive DS3 Framer block declares the OOF defect condition, as described below. ` 0 - Configures the Transmit DS3 Framer block to NOT automatically transmit the FERF/RDI indicator, whenever (and for the duration that) the Receive DS3 Framer block declares the OOF defect condition. ` 1 - Configures the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator whenever (and for the duration that) the Receive DS3 Framer block declares the OOF defect condition. BIT 0 - Transmit FERF/RDI upon AIS This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, anytime (and for the duration that) the Receive DS3 Framer block declares the AIS defect condition, as described below. ` 0 - Configures the Transmit DS3 Framer block to NOT automatically transmit the FERF/RDI indicator, whenever (and for the duration that) the Receive DS3 Framer block declares the AIS defect condition. ` 1 - Configures the Transmit DS3 Framer block to automatically transmit the FERF/RDI indicator, whenever (and for the duration that) the Receive DS3 Framer block declares the AIS defect condition. TABLE 280: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC CONFIGURATION & STATUS REGISTER (ADDRESS = 0X0E31) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit FEAC Interrupt Enable Transmit FEAC Interrupt Status Transmit FEAC Controller Enable Transmit FEAC Message Transmit FEAC Busy R/O R/O R/O R/W RUR R/W R/W R/O 0 0 0 0 0 0 0 0 BIT [7:5] - Unused: Please set these bits to [0, 0, 0] for normal operation. BIT 4 - Transmit FEAC Interrupt Enable: 209 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This READ/WRITE bit-field is used to either enable or disable the Transmit FEAC Interrupt. If the user enables this interrupt, then the Transmit FEAC Controller block (within the Transmit DS3 Framer block) will generate an interrupt, once it has completed its 10th transmission of a given FEAC Message to the remote terminal equipment. ` 0 - Disables the Transmit FEAC Interrupt ` 1 - Enables the Transmit FEAC Interrupt. NOTE: This bit-field is only active if the Transmit and Receive DS3 Framer blocks have been configured to support the C-bit Parity Framing format. BIT 3 - Transmit FEAC Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Transmit FEAC Controller block has generated the Transmit FEAC interrupt since the last read of this register. ` 0 - Indicates that the Transmit FEAC Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Transmit FEAC Interrupt has occurred since the last read of this register. BIT 2 - Transmit FEAC Controller Enable: This READ/WRITE bit-field is used to either enable or disable the Transmit FEAC Controller, within the Transmit DS3 Framer block. ` 0 - Disables the Transmit FEAC Controller block. ` 1 - Enables the Transmit FEAC Controller block BIT 1 - Transmit FEAC Message: ` A 0 to 1 transition, within this bit-field configures the Transmit FEAC Controller block to begin its transmission of the FEAC Message (which consists of the FEAC Code, as specified within the Transmit DS3 FEAC Register. NOTE: The user is advised to perform a write operation that resets this bit-field back to 0, following execution of the command to transmit a FEAC Message. BIT 0 - Transmit FEAC Busy: This READ-ONLY bit-field indicates whether or not the Transmit FEAC Controller block is currently busy transmitting a FEAC Message to the remote terminal. ` 0 - Indicates that the Transmit FEAC Controller is NOT currently busy transmitting a given FEAC Message. ` 1 - Indicates that the Transmit FEAC Controller is currently busy transmitting a given FEAC Message to the remote terminal equipment. TABLE 281: DS3 FRAMER BLOCK - TRANSMIT DS3 FEAC REGISTER (ADDRESS = 0X0E32) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 TxFEAC_Code[5:0] BIT 0 Unused R/O R/W R/W R/W R/W R/W R/W R/O 0 1 1 1 1 1 1 0 BIT 7 - Unused: BIT [6:1] - TxFEAC_Code[5:0]: These six (6) READ/WRITE bit-fields permit the user to specify the FEAC Code word that the Transmit FEAC Controller block (within the Transmit DS3 Framer block) should transmit to the remote terminal equipment. Once the user enables the Transmit FEAC Controller and commands it to begin its transmission, the Transmit FEAC Controller will then (1) encapsulate this six-bit code word into a 16-bit structure, and (2) proceed to transmit this 16-bit structure 10 times, repeatedly, and then halt. NOTE: These bit-fields are ignored if the user does not enable and use the Transmit FEAC Controller. BIT 0 - Unused: 210 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 282: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD CONFIGURATION REGISTER (ADDRESS = 0X0E33) BIT 7 BIT 6 Transmit LAPD Any BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Auto Retransmit Reserved Transmit LAPD Message Length Transmit LAPD Controller Enable R/W R/O R/O R/O R/W R/O R/W R/W 0 0 0 0 1 0 0 0 BIT 7 - Transmit LAPD Any: This READ/WRITE bit-field is used to configure the Transmit LAPD Controller block to transmit any kind of LAPD Message (or HDLC Message) with a size of 82 bytes or less. If the user implements this option, then the Transmit LAPD Controller block will be capable of transmitting any kind of HDLC frame (with any value of header bytes). The only restriction is that the size of the HDLC frame must not exceed 82 bytes. ` 0 - Does not invoke this Any Kind of HDLC Message feature. In this case, the Transmit LAPD Controller block will only transmit HDLC Messages that contains the Bellcore GR-499-CORE values for SAPI and TEI. ` 1 - Invokes this Any Kind of HDLC Message feature. In this case, the Transmit LAPD Controller block will be able to transmit HDLC Messages that contains any header byte values. NOTE: If the Any Kind of HDLC Message feature is invoked, then the size of the information payload (in terms of bytes) within the Transmit LAPD byte Count Register Address = 0x0E83) must be indicated. BIT [6:4] - Unused: BIT 3 - Auto Retransmit This READ/WRITE bit-field is used to configure the Transmit LAPD Controller block to transmit PMDL messages, repeatedly at one-second intervals. Once the user enables this feature, and then commands the Transmit LAPD Controller block to transmit a given PMDL Message, then the Transmit LAPD Controller block will then proceed to transmit this PMDL Message (based upon the contents within the Transmit LAPD Message Buffer) repeatedly at one second intervals. ` 0 - Disables the Auto-Retransmit Feature: In this case, the Transmit LAPD Controller block will only transmit a given PMDL Message once. Afterwards the Transmit LAPD Controller block will proceed to transmit a continuous stream of Flag Sequence octets (0x7E) via the DL bits, within each output DS3 frame. No more PMDL Messages will be transmitted until the user commands another transmission. ` 1 - Enables the Auto-Retransmit Features In this case, the Transmit LAPD Controller block will transmit PMDL messages (based upon the contents within the Transmit LAPD Message buffer) repeatedly at one-second interval.s NOTE: This bit-field is ignored if the Transmit LAPD Controller block is disabled. BIT 2 - Reserved: BIT 1 - Transmit LAPD Message Length: This READ/WRITE bit-field is used to specify the length of the payload data within the outbound LAPD/PMDL Message, as indicated below. ` 0 - Configures the Transmit LAPD Controller block to transmit a LAPD/PMDL Message that has a payload data size of 76 bytes. ` 1 - Configures the Transmit LAPD Controller block to transmit a LAPD/PMDL Message that has a payload data size of 82 bytes. BIT 0 - Transmit LAPD Controller Enable: This READ/WRITE bit-field is used to enable the Transmit LAPD Controller block within the chip. Once the user enables the Transmit LAPD Controller block, it will immediately begin transmitting the Flag Sequence octet (0x7E) to the remote terminal via the DL within the outbound DS3 data-stream. The Transmit LAPD Controller block will continue to do this until the user commands the Transmit LAPD Controller block to transmit a PMDL Message. ` 0 - Disables the Transmit LAPD Controller block. 211 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 1 - Enables the Transmit LAPD Controller block. TABLE 283: DS3 FRAMER BLOCK - TRANSMIT DS3 LAPD STATUS/INTERRUPT REGISTER (ADDRESS = 0X0E34) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Transmit LAPD Message Start Transmit LAPD Controller Busy Transmit LAPD Interrupt Enable Transmit LAPD Interrupt Status R/O R/O R/O R/O R/W R/O R/W RUR 0 0 0 0 0 0 0 0 BIT [7:4] - Unused: BIT 3 - Transmit LAPD Message Start: ` A 0 to 1 transition within this bit-field commands the Transmit LAPD Controller block to begin the following activities. • Reading out the contents of the Transmit LAPD Message buffer. • Zero-stuffing of this data • FCS Calculation and Insertion • Fragmentation of this composite PMDL Message, and insertion into the DL bit-fields, within each outbound DS3 frame. BIT 2 - Transmit LAPD Controller Busy: This READ-ONLY bit-field indicates whether or not the Transmit LAPD Controller block is currently busy transmitting a PMDL Message to the remote terminal equipment. The user can continuously poll this bit-field in order to check for completion of transmission of the LAPD/PMDL Message. ` 0 - Indicates that the Transmit LAPD Controller block is NOT currently busy transmitting a PMDL message. ` 1 - Indicates that the Transmit LAPD Controller block is currently busy transmitting a PMDL message. BIT 1 - Transmit LAPD Message Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Transmit LAPD Message Interrupt. If the user enables this interrupt, then the Transmit DS3 Framer block will generate an interrupt anytime the Transmit LAPD Controller block has completed its transmission of a given LAPD/PMDL Message to the remote terminal. ` 0 - Disables the Transmit LAPD Message Interrupt. ` 1 - Enables the Transmit LAPD Message Interrupt. BIT 0 - Transmit LAPD Message Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Transmit LAPD Message Interrupt has occurred since the last read of this register. ` 0 - Indicates that the Transmit LAPD Message Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the Transmit LAPD Message Interrupt has occurred since the last read of this register. TABLE 284: DS3 FRAMER BLOCK - TRANSMIT DS3 M-BIT MASK REGISTER (ADDRESS = 0X0E35) BIT7 BIT6 BIT 5 TxFEBEDat[2:0] BIT 4 BIT 3 FEBE Register Enable Transmit PBit Error BIT 2 BIT 1 BIT 0 TxM_Bit_Mask[2:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 5 - TxFEBEDat[2:0] These READ/WRITE bit-fields, along with BIT 4 (FEBE Register Enable) are used to configure the Transmit DS3 Framer block to transmit the user-specified FEBE values (to the remote terminal equipment) based upon the contents of these bit-fields. 212 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS If the user sets the FEBE Register Enable bit-field to '1, then the Transmit DS3 Framer block will wsrite the contents of these bit-fields into the FEBE bit-fields within each outbound DS3 frame. If the user sets the FEBE Register Enable bit-field to 0, then these register bits will be ignored. BIT 4 - FEBE Register Enable This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit user-specified FEBE values (to the remote terminal equipment) per register setting via the TxFEBEDat[2:0] bit-fields. This option is used to exercise software control over the outbound FEBE values, within the outbound DS3 data-stream. ` 0 - Configures the Transmit DS3 Framer block to set the FEBE bit-fields (within each outbound DS3 frame) to the appropriate values based upon receive conditions, as determined by the Receive DS3 Framer block. ` 1 - Configures the Transmit DS3 Framer block to set the write the contents of the TxFEBEDat[2:0] bit-fields into the FEBE bit-positions within each outbound DS3 frame. BIT 3 - Transmit P-Bit Error This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with erred Pbits as indicated below. ` 0 - Configures the Transmit DS3 Framer block to generate and transmit DS3 frames (with correct P-bit values) to the remote terminal equipment. ` 1 - Configures the Transmit DS3 Framer block to generate and transmit DS3 frames (with erred P-bit values) to the remote terminal equipment. BIT[2:0] - TxM_Bit_Mask[2:0] These READ/WRITE bit-fields are used to configure the Transmit DS3 Framer block to transmit DS3 frames with erred M-bits. These three (3) bit-fields corresponding to each of the three M-bits, within each outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of these bit-fields and the values of the three M-bits. The results of this calculation will be written back into the M-bit position within each outbound DS3 frame. NOTE: The user should set these bit-fields to 0, 0, 0 for normal (e.g., un-erred) operation. TABLE 285: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTERS # 1 (ADDRESS = 0X0E36) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 F-Bit Mask[27] F-Bit Mask[26] F-Bit Mask[25] F-Bit Mask[24] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT[7:4] - Unused BIT 3 - F-Bit Mask[27]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 28th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 28th F-bit. The results of this calculation will be written back into the 28th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 2 - F-Bit Mask[26]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 27th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 27th F-bit. The results of this calculation will be written back into the 27th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 1 - F-Bit Mask[25]: 213 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 26th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 26th F-bit. The results of this calculation will be written back into the 26th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 0 - F-Bit Mask[24]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 25th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 25th F-bit. The results of this calculation will be written back into the 25th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. TABLE 286: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 2 (ADDRESS = 0X0E37) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 F-Bit Mask[23] F-Bit Mask[22] F-Bit Mask[21] F-Bit Mask[20] F-Bit Mask[19] F-Bit Mask[18] F-Bit Mask[17] F-Bit Mask[16] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - F-Bit Mask[23]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 24th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 24th F-bit. The results of this calculation will be written back into the 24th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT6 - F-Bit Mask[22]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 23rd F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 23rd F-bit. The results of this calculation will be written back into the 23rd F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 5 - F-Bit Mask[21]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 22nd F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 22nd F-bit. The results of this calculation will be written back into the 22nd F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 4 - F-Bit Mask[20]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 21st F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 21st F-bit. The results of this calculation will be written back into the 21st F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 3 - F-Bit Mask[19]: 214 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 20th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 20th F-bit. The results of this calculation will be written back into the 20th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 2 - F-Bit Mask[18]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 19th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 19th F-bit. The results of this calculation will be written back into the 19th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 1 - F-Bit Mask[17]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 18th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 18th F-bit. The results of this calculation will be written back into the 18th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. BIT 0 - F-Bit Mask[16]: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit DS3 frames with a single/particular erred F-bit. This particular F-bit corresponds with the 17th F-bit within a given outbound DS3 frame. The Transmit DS3 Framer block will perform an XOR operation with the contents of this bit-field and the value of the 17th F-bit. The results of this calculation will be written back into the 17th F-bit position, within each outbound DS3 frame. NOTE: The user should set this bit-field to 0 for normal (e.g., un-erred) operation. TABLE 287: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 3 (ADDRESS = 0X0E38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 F-Bit Mask[15] F-Bit Mask[14] F-Bit Mask[13] F-Bit Mask[12] F-Bit Mask[11] F-Bit Mask[10] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 F-Bit Mask[9] F-Bit Mask[8] BIT [7:0] - See Table 286 above, for bit descriptions, substituting Mask [15:8] for mask[23:16] TABLE 288: DS3 FRAMER BLOCK - TRANSMIT DS3 F-BIT MASK REGISTER # 4 (ADDRESS = 0X0E39) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 F-Bit Mask[7] F-Bit Mask[6] F-Bit Mask[5] F-Bit Mask[4] F-Bit Mask[3] F-Bit Mask[2] F-Bit Mask[1] F-Bit Mask[0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 286 above, for bit descriptions, substituting Mask [7:0] for mask[23:16] 215 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 289: DS3 FRAMER BLOCK - M12 DS2 # 1 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT 7 - Unused: BIT 6 - One and Only: This READ/WRITE bit-field is used to select the F-bit acquisition criteria that the M12 DeMUX block will use, whenever it is operating in the F-Bit Search state, as described below. ` 0 - Configures the M12 De-MUX block to move onto the M-Bit Search state, whenever it has properly located 8 (or 16) consecutive F-bits (as configured in Bit 4 of this register). ` 1 - Configures the M12 De-MUX block to move onto the M-Bit Search state, whenever it has (1) properly located 8 (or 16) consecutive F-bits and (2) when it has located and identified only one viable F-Bit Alignment candidate. NOTE: If the user sets this bit-field to 1, then the M12 De-MUX block will NOT transition into the M-Bit Search state as long as at least two viable candidate sets of bits appears to function as the F-bits. BIT 5 - DS2 M-Sync: This READ/WRITE bit-field is used to select the M-Bit Acquisition criteria whenever the M12 De-MUX block is operating in the M-Bit Search state. ` 0 - Configures the M12 De-MUX block to declare the In-Frame state, when it has properly located 4 consecutive Mbits (while detecting no F-bit errors). ` 1 - Configures the M12 De-MUX block to declare the In-Frame state, when it has properly located 8 consecutive Mbits (while detecting no F-bit errors). BIT 4 - DS2 F-Sync: This READ/WRITE bit-field is used to select the F-Bit Acquisition criteria whenever the M12 De-MX block is operating in the F-Bit Search state. ` 0 - Configures the M12 De-MUX block to move onto the M-Bit Search state, when it has properly located 8 consecutive F-bits. ` 1 - Configures the M12 De-MUX block to move onto the M-Bit Search state, when it has properly located 16 consecutive F-bits. BIT 3 - DS2 LOF - F Bits/G.747 FAS Bit Error Count The exact function of this bit-field depends upon whether the M12 MUX/De-MUX block has been configured to operate in the DS2 or in the G.747 Mode, as described below. If M12 MUX/M12 De-MUX # 1 is configured to operate in the DS2 Mode: This READ/WRITE bit-field is used to select the F-Bit LOF (Loss of Frame) Defect criteria for the M12 De-MUX associated with DS2 Channel 1. ` 0 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition whenever the M12 De-MUX block detects two (2) F-bit errors within the four (4) most recently received F-bits within the incoming DS2 data-stream. ` 1 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition whenever the M12 De-MUX defect two (2) F-bit errors within the five (5) most recently received F-bits within the incoming DS2 data-stream. If M12 MUX/M12 De-MUX # 1 is configured to operate in the G.747 Mode: This READ/WRITE bit-field is used to specify how the M12 De-MUX increments G.747 Framing Alignment Signal (FAS) errors. The user can configure the M12 De-MUX to increment the PMON DS2 # 1 Framing Bit Error Count Register on either 216 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS a per-bit or per-frame basis, as described below. Per-Bit Basis: The M12 De-MUX will increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count Register once for each bit-error that it detects within the FAS bit-fields of the incoming G.747 data-stream. Per-Frame Basis: The M12 De-MUX will increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count Register once for each time it detects at least one bit-error within the FAS bit-fields of a given incoming G.747 frame. ` 0 - Configures the M12 De-MUX to increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count Register on a per-bit basis. ` 1 - Configures the M12 De-MUX block to increment the DS3 Framer Block - PMON DS2 # 1 Framing Bit Error Count Register on a per-frame basis. BIT 2 - DS2 LOF - M Bits This READ/WRITE bit-field is used to select the M-Bit LOF (Loss of Frame) Defect criteria for the M12 De-MUX block associated with DS2 Channel 1. ` 0 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition whenever the M12 De-MUX block detects M-bit errors within three (3) out of the four (4) most recently received DS2 M-frames. ` 1 - Configures the M12 De-MUX block to declares the DS2 LOF defect condition whenever the M12 De-MUX block detects M-bit errors within two (2) out of the four (4) most recently received DS2 M-frames. BIT 1 - DS2 LOF - M Bits Disable This READ/WRITE bit-field is used to configure the M12 De-MUX block to not use M-bit errors as a reason/criteria for declaring the DS2 LOF defect condition. ` 0 - Configures the M12 De-MUX block to declare the DS2 LOF defect condition, based upon the number of M-bit errors (as selected in Bit 2 within this register). ` 1 - Configures the M12 De-MUX block to NOT declare the DS2 LOF defect condition, based upon the occurrences of any M-bit errors. BIT 0 - DS2 Reframe: ` A 0 to 1 transition, within this bit-field commands the M12 De-MUX block to exit the Frame Maintenance mode, and go back and enter the Frame Acquisition Mode. NOTE: The user should go back and set this bit-field to 0 following execution of the Reframe Command. TABLE 290: DS3 FRAMER BLOCK - M12 DS2 # 2 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit [7:0] - See bit description for Table 289, above. 217 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 291: DS3 FRAMER BLOCK - M12 DS2 # 3 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit [7:0] - See bit description for Table 289, above. TABLE 292: DS3 FRAMER BLOCK - M12 DS2 # 4 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit [7:0] - See bit description for Table 289, above. TABLE 293: DS3 FRAMER BLOCK - M12 DS2 # 5 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit [7:0] - See bit description for Table 289, above. 218 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 294: DS3 FRAMER BLOCK - M12 DS2 # 6 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E3F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit [7:0] - See bit description for Table 289, above. TABLE 295: DS3 FRAMER BLOCK - M12 DS2 # 7 FRAMER CONFIGURATION REGISTER (ADDRESS = 0X0E40) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused One and Only DS2 M-Sync DS2 F-Sync DS2 LOF - F Bits/ G.747 FAS Bit Error Count DS2 LOF - M Bits DS2 LOF - M Bits Disable DS2 Reframe R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit [7:0] - See bit description for Table 289, above. TABLE 296: DS3 FRAMER BLOCK - TRANSMIT DS3 PATTERN REGISTER (ADDRESS = 0X0E4C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit AIS - Unframed All Ones Transmit AIS - C bits not forced to 0 Transmit AIS - Ignore Overhead Data from TxDS3OH Port Transmit LOS Pattern - All Ones Pattern R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 1 1 0 0 DS3 Idle Pattern[3:0] BIT7 - Transmit AIS - Unframed All Ones: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit either of the following patterns, anytime it is configured to transmit the AIS indicator. • A Framed, repeating 1, 0, 1, 0… pattern (per Bellcore GR-499-CORE) or • An Unframed All Ones Pattern. ` 0 - Configures the Transmit DS3 Framer block to transmit the Framed, Repeating 1, 0, 1, 0,… Pattern, whenever it is configured to transmit the AIS Indicator. ` 1 - Configures the Transmit DS3 Framer block to transmit an Unframed, All Ones Pattern, whenever it is configured to transmit the AIS indicator. BIT6 - Transmit AIS - C Bits NOT forced to 0 219 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This READ/WRITE bit-field (along with the Transmit AIS - Unframed All Ones bit-field) is used to define the type of AIS data-stream that the Transmit DS3 Framer block will transmit, as described below. ` 0 - Configures the Transmit DS3 Framer block to force all of the C bits to 0 when it is configured to transmit a Framed AIS signal. ` 1 - Configures the Transmit DS3 Framer block to NOT force all of the C bits to 0 when it is configured to transmit a Framed AIS signal. In this case, the C bits can be used to transport FEAC or PMDL Messages. NOTE: This bit-field is ignored if the Transmit DS3 Framer block has been configured to transmit an Unframed - All Ones type of AIS signal. BIT 5 - Transmit AIS - Ignore Overhead Data from TxDS3OH Port This READ/WRITE bit-field permits the Transmit DS3 Framer block to either accept or ignore externally supplied DS3 Overhead data, whenever it (the Transmit DS3 Framer block) is transmitting the AIS indicator. If this feature is used, then (for the duration that the Transmit DS3 Framer block is commanded to transmit the DS3 AIS indicator) the Transmit DS3 Framer block will NOT allow the users to externally insert their DS3 OH bits within the outbound DS3 data-stream, even if the TxOH Source bit-field is set to 1 and if the corresponding F-Bit Mask bit-field is set to 0. Conversely, if the user does NOT use this feature, then the Transmit DS3 Framer block will allow the users to externally insert theirr own DS3 OH bits (within the outbound DS3 data-stream) even when the Transmit DS3 Framer block is transmitting the DS3 AIS indicator to the remote terminal equipment. ` 0 - Does NOT invoke the Ignore TxDS3OH Port During AIS Feature ` 1 - Invokes the Ignore the TxDS3OH Port During AIS feature. BIT 4 - Transmit LOS Pattern Select: This READ/WRITE bit-field is used to configure the Transmit DS3 Framer block to transmit either an All Zeros or an All Ones pattern, anytime it is configured to transmit the LOS Pattern to the remote terminal equipment, as described below. ` 0 - Configures the Transmit DS3 Framer block to transmit an All Zeros pattern whenever it is configured to transmit the LOS pattern. ` 1 - Configures the Transmit DS3 Framer block to transmit an All Ones pattern whenever it is configured to transmit the LOS pattern. BIT[3:0] - Transmit DS3 Idle Pattern[3:0] These READ/WRITE bit-fields are used to specify the type of framed, repetitive four-bit pattern that the Transmit DES3 Framer block should generate and transmit, whenever it is configured to transmit the DS3 Idle Pattern. NOTE: Setting these bit-fields to [1, 1, 0, 0] configures the Transmit DS3 Framer block to transmit the standard Framed, repeating 1, 1, 0, 0, … pattern (per Bellcore GR-499-CORE) requirements. TABLE 297: DS3 FRAMER BLOCK - AUTO T1/E1 AIS UPON DS3 DEFECT CONDITION REGISTER (ADDRESS = 0X0E4D) BIT7 BIT6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Auto DS1/E1AIS upon DS3 LOS Defect Unused Auto DS1/E1 AIS upon DS3 OOF Defect Unused Auto DS1/E1 AIS upon DS3 AIS Defect R/O R/O R/O R/W R/O R/W R/O R/W 0 0 0 0 0 0 0 0 Bits 7 - 5 - Unused BIT 4 - Auto DS1/E1 AIS upon DS3 LOS Defect This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive DS3 Framer block declares the LOS defect condition. ` 0 - Does not configure all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicators via the downstream DS1/E1 signals, anytime the Receive DS3 Framer block declares the LOS defect 220 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS condition. ` 1 - Configures all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicators via the downstream DS1/E1 signals anytime the Receive DS3 Framer block declares the LOS defect condition. NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in either the M13 MUX or the M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode. BIT 3 - Unused BIT 2 - Auto DS1/E1 AIS upon DS3 OOF Defect This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive DS3 Framer block declares the LOF/OOF defect condition. ` 0 - Does not configure all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicators via the downstream DS1/E1 signals, anytime the Receive DS3 Framer block declares the LOF/OOF defect condition. ` 1 - Configures all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicators via the downstream DS1/E1 signals anytime the Receive DS3 Framer block declares the LOF/OOF defect condition. NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in either the M13 MUX or the M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode. BIT 1 - Unused BIT 0 - Auto DS1/E1 AIS upon DS3 AIS Defect This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via the downstream DS1/E1 signals, anytime (and for the duration that) the Receive DS3 Framer block declares the AIS defect condition. ` 0 - Does not configure all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicators via the downstream DS1/E1 signals, anytime the Receive DS3 Framer block declares the AIS defect condition. ` 1 - Configures all Egress Direction Transmit DS1/E1 Framer blocks to automatically transmit the DS1/E1 AIS indicators via the downstream DS1/E1 signals anytime the Receive DS3 Framer block declares the AIS defect condition. NOTE: This bit-field is only active if the XRT86SH328 has been configured to operate in either the M13 MUX or the M13 MUX which is Asynchronously mapped into STS-1/STS-3 Mode. TABLE 298: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E4E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON EXZ Event Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON EXZ_Event_Count[15:8]: These RESET-upon-READ bits, along with that within the PMON Excessive Zero Count Register - LSB combine to reflect the cumulative number of instances in which the Receive DS3 Framer block has detected a string of three or more consecutive zeros within the incoming DS3 data-stream, since the last read of this register. This register contains the Most Significant Byte of this 16-bit expression. 221 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 299: DS3 FRAMER BLOCK - PMON EXCESSIVE ZERO (EXZ) EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E4F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON EXZ Event Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON EXZ_Event_Count[7:0]: These RESET-upon-READ bits, along with that within the PMON Excessive Zero Count Register -MSB combine to reflect the cumulative number of instances in which the Receive DS3 Framer block has detected a string of three or more consecutive zeros within the incoming DS3 data-stream, since the last read of this register. This register contains the Least Significant Byte of this 16-bit expression. TABLE 300: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E50) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON LCV Event Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON LCV_Event_Count[15:8]: These RESET-upon-READ bits along with that within the PMON Line Code Violation Count - LSB register combine to reflect the cumulative number of Line Code Violation events that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, since the last read of this register. This register contains the Most Significant byte of this 16-bit expression. TABLE 301: DS3 FRAMER BLOCK - PMON LINE CODE VIOLATION (LCV) EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E51) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON LCV Event Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON LCV_Event_Count[7:0]: These RESET-upon-READ bits along with that within the PMON Line Code Violation Count - MSB register combine to reflect the cumulative number of Line Code Violation events that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, since the last read of this register. This register contains the Least Significant byte of this 16-bit expression. TABLE 302: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E52) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_Framing_Bit_Error_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 222 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT [7:0]: PMON Framing Bit ErrorCount[15:8]: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON Framing Bit Error Count Register - LSB combine to reflect the cumulative number of Framing bit errors that the Receive DS3 Framer block has detected since the last read of this register. This register contains the Most Significant byte of this 16-bit expression. NOTE: The Receive DS3 Framer block will increment this register each time that it detects F or M bit errors within the incoming DS3 data-stream. TABLE 303: DS3 FRAMER BLOCK - PMON FRAMING BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E53) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_Framing_Bit_Error_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0]: PMON Framing Bit ErrorCount[7:0]: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON Framing Bit Error Count Register - MSB combine to reflect the cumulative number of Framing bit errors that the Receive DS3 Framer block has detected since the last read of this register. This register contains the Least Significant byte of this 16-bit expression. NOTE: The Receive DS3 Framer block will increment this register each time that it detects F or M bit errors within the incoming DS3 data-stream. TABLE 304: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E54) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_P_Bit _Error_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0]: PMON P-Bit Error Count[15:8]: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON P-bit Error Count Register - LSB combine to reflect the cumulative number of P-bit errors that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, since the last read of this register. This register contains the Most Significant byte of this 16-bit expression. TABLE 305: DS3 FRAMER BLOCK - PMON P-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E55) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_P_Bit_Error_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON P-Bit Error Count[7:0]: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON P-bit Error Count Register - MSB combine to reflect the cumulative number of P-bit errors that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, since the last read of this register. This register contains the Least Significant byte of this 16-bit expression. 223 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 306: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - MSB (ADDRESS = 0X0E56) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_FEBE_Event_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON FEBE Event Count[15:8]: These RESET-upon-READ bits, along with that within the PMON FEBE Event Count Register - LSB combine to reflect the cumulative number of FEBE/REI events that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, since the last read of this register. This register contains the Most Significant byte of this 16-expression. TABLE 307: DS3 FRAMER BLOCK - PMON FEBE EVENT COUNT REGISTER - LSB (ADDRESS = 0X0E57) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_FEBE_Event_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON FEBE Event Count[7:0]: These RESET-upon-READ bits, along with that within the PMON FEBE Event Count Register - MSB combine to reflect the cumulative number of FEBE/REI events that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, since the last read of this register. This register contains the Least Significant byte of this 16-expression. TABLE 308: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E58) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_CP_Bit_Error_Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON CP-Bit Error Count[15:8]: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON CP-Bit Error Count Register - LSB combine to reflect the cumulative number of CP bit errors that the Receive DS3 Framer block has detected since the last read of this register. This register contains the Most Significant byte of this 16-bit expression. NOTE: These register bits are not active if the Transmit and Receive DS3 Framer blocks have NOT been configured to support the DS3 C-bit Parity Framing format. TABLE 309: DS3 FRAMER BLOCK - CP-BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E59) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_CP_Bit_Error_Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON CP-Bit Error Count[7:0]: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PMON CP-Bit Error Count Register MSB combine to reflect the cumulative number of CP bit errors that the Receive DS3 Framer block has detected since the last read of this register. This register contains the Least Significant byte of this 16-bit expression. 224 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: These register bits are not active if the Transmit and Receive DS3 Framer blocks have NOT been configured to support the DS3 C-bit Parity Framing format. TABLE 310: DS3 FRAMER BLOCK - PMON DS2 # 1 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5A) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 1 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON DS2 # 1 - Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0]: The function of this bit-field depends upon whether M12 MUX/De-MUX # 1 has been configured to operate in the DS2 or in the G.747 Mode. If M12 MUX/De-MUX # 1 has been configured to operate in the DS2 Mode: These RESET-upon-READ bit-fields reflects the cumulative number of F and M bit errors that the M12 De-MUX Block (associated with DS2 Channel 1) has detected since the last read of this register. If M21 MUX/De-MUX # 1 has been configured to operate in the G.747 Mode: This RESET-upon-READ bit-fields reflects the cumulative number of FAS errors that the M12 De-MUX block (associated with DS2 Channel 1) has detected since the last read of this register. TABLE 311: DS3 FRAMER BLOCK - PMON DS2 # 2 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5B) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 2 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] See Figure 310 above, for bit descriptions TABLE 312: DS3 FRAMER BLOCK - PMON DS2 # 3 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 3 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] See Figure 310 above, for bit descriptions TABLE 313: DS3 FRAMER BLOCK - PMON DS2 # 4 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 4 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] See Figure 310 above for bit descriptions 225 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 314: DS3 FRAMER BLOCK - PMON DS2 # 5 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 5 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] See Figure 310 above, for bit descriptions TABLE 315: DS3 FRAMER BLOCK - PMON DS2 # 6 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E5F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 6 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] See Figure 310 above, for bit descriptions TABLE 316: DS3 FRAMER BLOCK - PMON DS2 # 7 FRAMING BIT ERROR COUNT REGISTER (ADDRESS = 0X0E60) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_DS2 # 7 Framing Bit Error Count[7:0]/G.747 FAS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] See Figure 310 above for bit descriptions TABLE 317: DS3 FRAMER BLOCK - PMON G.747 # 1 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E61) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 1 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PMON G.747 # 1 - Parity Error Count[7:0]: This RESET-upon-READ bit-field reflects the cumulative number of P-bit errors that the M12 De-MUX Block (associated with G.747 Channel # 1) has detected since the last read of this register. NOTE: These bit-fields are only active if M12 MUX/De-MUX # 1 has been configured to operate in the G.747 Mode. TABLE 318: DS3 FRAMER BLOCK - PMON G.747 # 2 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E62) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 2 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 2 for Channel # 1. 226 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 319: DS3 FRAMER BLOCK - PMON G.747 # 3 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E63) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 3 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 3 for Channel # 1. TABLE 320: DS3 FRAMER BLOCK - PMON G.747 # 4 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E64) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 4 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 4 for Channel # 1. TABLE 321: DS3 FRAMER BLOCK - PMON G.747 # 5 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E65) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 5 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 5 for Channel # 1. TABLE 322: DS3 FRAMER BLOCK - PMON G.747 # 6 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E66) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 6 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 6 for Channel # 1. TABLE 323: DS3 FRAMER BLOCK - PMON G.747 # 7 PARITY BIT ERROR COUNT REGISTER (ADDRESS = 0X0E67) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PMON_G.747 # 7 - Parity Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 317 above, for bit descrptions, substituting Channel # 7 for Channel # 1. 227 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 324: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - MSB (ADDRESS = 0X0E68) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PRBS Error Count[15:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PRBS Error Count - Upper Byte: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PRBS Bit Error Count Register - LSB combine to reflect the cumulative number of PRBS bit errors that the PRBS Receiver (within the Receive DS3 Framer block) has detected since the last read of this register. This register contains the Most Significant byte of this 16-bit expression. NOTE: This register is only active of the PRBS Receiver (within the Receive DS3 Framer block) has been enabled. TABLE 325: DS3 FRAMER BLOCK - PRBS BIT ERROR COUNT REGISTER - LSB (ADDRESS = 0X0E69) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PRBS Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - PRBS Error Count - Lower Byte: These RESET-upon-READ bits, along with that within the DS3 Framer Block - PRBS Bit Error Count Register - MSB combine to reflect the cumulative number of PRBS bit errors that the PRBS Receiver (within the Receive DS3 Framer block) has detected since the last read of this register. This register contains the Least Significant byte of this 16-bit expression. NOTE: This register is only active of the PRBS Receiver (within the Receive DS3 Framer block) has been enabled. TABLE 326: DS3 FRAMER BLOCK - ONE SECOND ERROR STATUS REGISTER (ADDRESS = 0X0E6D) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Erred Second Severely Erred Second R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:2] - Unused: BIT 1 - Erred Second: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block has declared the last one-second accumulation period as an Erred Second. The Receive DS3 Framer block will declare an Erred Second if it detects any of the following events, within a given onesecond period. • P-Bit Errors • CP-Bit Errors • Framing Bit (F or M) Errors ` 0 - Indicates that the Receive DS3 Framer block has NOT declared the last one-second accumulation period as being an Erred Second. 228 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 1 - Indicates that the Receive DS3 Framer block has declared the last one-second accumulation period as being an Erred Second. BIT 0 - Severely Erred Second: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block has declared the last onesecond accumulation period as being a Severely Erred Second. The Receive DS3 Framer block will declares a given one-second period as being a severely erred second if it determines that the BER (Bit Error Rate) during this one-second accumulation period is greater than 10-3 errors/second. ` 0 - Indicates that the Receive DS3 Framer block has NOT declared the last one-second accumulation period as being a severely-erred second. ` 1 - Indicates that the Receive DS3 Framer block has declared the last one-second accumulation period as being a severely-erred second. TABLE 327: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E6E) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 One_Second_LCV_Accum_Count[15:8] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - One-Second LCV Accumulation Count[15:8]: These READ-ONLY bits, along with that within the DS3 Framer Block - One Second LCV Accumulation Count Register - MSB combine to reflect the cumulative number of Line Code Violations that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Most Significant byte of this 16-bit expression. NOTE: This register is only active if the XRT86SH328 has been configured to operate in the M13 MUX Mode. TABLE 328: DS3 FRAMER BLOCK - LCV ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E6F) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 One_Second_LCV_Accum_Count[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - One-Second LCV Accumulation Count[7:0]: These READ-ONLY bits, along with that within the DS3 Framer Block - One Second LCV Accumulation Count Register - LSB combine to reflect the cumulative number of Line Code Violations that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Least Significant byte of this 16-bit expression. NOTE: This register is only active if the XRT86SH328 has been configured to operate in the M13 MUX Mode. TABLE 329: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E70) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 One_Second_P_Bit_Error_Accum_Count[15:8] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - One-Second P-Bit Error Accumulation Count[15:8]: 229 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 These READ-ONLY bits, along with that within the DS3 Framer Block - One Second P-Bit Error Accumulation Count Register - LSB combine to reflect the cumulative number of P-Bit errors that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Most Significant byte of this 16-bit expression. TABLE 330: DS3 FRAMER BLOCK - P-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E71) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 One_Second_P_Bit_Error_Accum_Count[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - One-Second P-Bit Error Accumulation Count[7:0]: These READ-ONLY bits, along with that within the DS3 Framer Block - One Second P-Bit Error Accumulation Count Register - MSB combine to reflect the cumulative number of P-Bit errors that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Least Significant byte of this 16-bit expression. TABLE 331: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X0E72) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 One_Second_CP_Bit_Error_Accum_Count[15:8] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - One-Second CP-Bit Error Accumulation Count[15:8]: These READ-ONLY bits, along with that within the DS3 Framer Block - One Second CP-Bit Error Accumulation Count Register - LSB combine to reflect the cumulative number of CP-Bit errors that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Most Significant byte of this 16-bit expression. NOTE: This register is only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in the DS3, C-bit Parity Framing format. TABLE 332: DS3 FRAMER BLOCK - CP-BIT ERROR ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X0E73) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 One_Second_CP_Bit_Error_Accum_Count[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - One-Second CP-Bit Error Accumulation Count[7:0]: These READ-ONLY bits, along with that within the DS3 Framer Block - One Second CP-Bit Error Accumulation Count Register - MSB combine to reflect the cumulative number of CP-Bit errors that the Receive DS3 Framer block has detected within the incoming DS3 data-stream, during the last one-second accumulation period. This register contains the Least Significant byte of this 16-bit expression. NOTE: This register is only active if the Transmit and Receive DS3 Framer blocks have been configured to operate in the DS3, C-bit Parity Framing format. 230 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 333: DS3 FRAMER BLOCK - TRANSMIT LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E83) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Tx_LAPD_MESSAGE_SIZE[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - Transmit LAPD Message Size[7:0]: These READ/WRITE bit-fields permit the user to specify the size of the information payload (in terms of bytes) within the very next outbound LAPD/PMDL Message whenever Bit 7 (Transmit LAPD Any) within the DS3 Framer Block Transmit LAPD Configuration Register has been set to 1. TABLE 334: DS3 FRAMER BLOCK - RECEIVE LAPD BYTE COUNT REGISTER (ADDRESS = 0X0E84) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Rx_LAPD_MESSAGE_SIZE[7:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Receive LAPD Message Size[7:0]: These READ-ONLY bit-fields indicate the size of the most recently received LAPD/PMDL Message, whenever Bit 7 (Receive LAPD Any) within the DS3 Framer Block - Receive LAPD Control Register has been set to 1. The contents of this register reflect the Receive LAPD Message size, in terns of bytes. TABLE 335: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT ENABLE REGISTER (ADDRESS = 0X0E90) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Change of DS2 Loopback Request DS2 Channel 6 Interrupt Enable Change of DS2 Loopback Request DS2 Channel 5 Interrupt Enable Change of DS2 Loopback Request DS2 Channel 4 Interrupt Enable Change of DS2 Loopback Request DS2 Channel 3 Interrupt Enable Change of DS2 Loopback Request DS2 Channel 2 Interrupt Enable Change of DS2 Loopback Request DS2 Channel 1 Interrupt Enable Change of DS2 Loopback Request DS2 Channel 0 Interrupt Enable R/O R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT6 - Change of DS2 Loop-back Request - DS2 Channel 6 Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of DS2 Loop-back Request Interrupt associated with DS2 Channel 6. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following events. • Whenever the Receive DS3 Framer block detects and flags the DS2 Loop-back request for DS2 Channel 6. • Whenever the Receive DS3 Framer block clears the DS2 Loop-back request for DS2 Channel 6. ` 0 - Disables the Change of DS2 Loop-back Request Interrupt for DS2 Channel 6. ` 1 - Enables the Change of DS2 Loop-back Request Interrupt for DS2 Channel 6. BIT 5 - Change of DS2 Loop-back Request - DS2 Channel 5 Interrupt Enable: 231 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 See description of BIT6. BIT 4 - Change of DS2 Loop-back Request - DS2 Channel 4 Interrupt Enable See description of BIT6. BIT 3 - Change of DS2 Loop-back Request - DS2 Channel 3 Interrupt Enable See description of BIT6. BIT 2 - Change of DS2 Loop-back Request - DS2 Channel 2 Interrupt Enable See description of BIT6. BIT 1 - Change of DS2 Loop-back Request - DS2 Channel 1 Interrupt Enable See description of BIT6. BIT 0 - Change of DS2 Loop-back Request - DS2 Channel 0 Interrupt Enable See description of BIT6. TABLE 336: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST INTERRUPT STATUS REGISTER (ADDRESS = 0X0E91) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Change of DS2 Loopback Request DS2 Channel 6 Interrupt Status Change of DS2 Loopback Request DS2 Channel 5 Interrupt Status Change of DS2 Loopback Request DS2 Channel 4 Interrupt Status Change of DS2 Loopback Request DS2 Channel 3 Interrupt Status Change of DS2 Loopback Request DS2 Channel 2 Interrupt Status Change of DS2 Loopback Request DS2 Channel 1 Interrupt Status Change of DS2 Loopback Request DS2 Channel 0 Interrupt Status R/O RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT6 - Change of DS2 Loop-back Request - DS2 Channel 6 Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Change of DS2 Loop-back Request Status interrupt for DS2 Channel 6 has occurred since the last read of this register. The XRT86SH328 will generate this interrupt in response to either of the following conditions. • Whenever the Receive DS3 Framer block detects and flags the DS2 Loop-back request, for DS2 Channel 6. • Whenever the Receive DS3 Framer block clears the DS2 Loop-back request for DS2 Channel 6. ` 0 - Indicates that the Change of DS2 Loop-back Request Status Interrupt has NOT occurred since the last read of this register ` 1 - Indicates that the Change of DS2 Loop-back Request Status Interrupt has occurred since the last read of this register. BIT 5 - Change of DS2 Loop-back Request - DS2 Channel 5 Interrupt Status See description of BIT6. BIT 4 - Change of DS2 Loop-back Request - DS2 Channel 4 Interrupt Status See description of BIT6. BIT 3 - Change of DS2 Loop-back Request - DS2 Channel 3 Interrupt Status See description of BIT6. BIT 2 - Change of DS2 Loop-back Request - DS2 Channel 2 Interrupt Status See description of BIT6. BIT 1 - Change of DS2 Loop-back Request - DS2 Channel 1 Interrupt Status See description of BIT6. 232 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT 0 - Change of DS2 Loop-back Request - DS2 Channel 0 Interrupt Status See description of BIT6. TABLE 337: DS3 FRAMER BLOCK - RECEIVE DS2 LOOP-BACK REQUEST STATUS REGISTER (ADDRESS = 0X0E92) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved Receive DS2 Loop-back Request ON - DS2 Channel 6 Receive DS2 Loop-back Request ON - DS2 Channel 5 Receive DS2 Loop-back Request ON - DS2 Channel 4 Receive DS2 Loop-back Request ON - DS2 Channel 3 Receive DS2 Loop-back Request ON - DS2 Channel 2 Receive DS2 Loop-back Request ON - DS2 Channel 1 Receive DS2 Loop-back Request ON - DS2 Channel 0 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT6 - Receive DS2 Loop-back Request ON - DS2 Channel 6: This READ-ONLY bit-field indicates whether or not the Receive DS3 Framer block has detected a DS2 Loop-back Request (associated with DS2 Channel # 6) within the incoming DS3 data-stream. The Receive DS3 Framer block will detect and flag a DS2 Loop-back Request if it detects the DS2 Loop-back Codes (pertaining to a given DS2 channel) for 5 consecutive DS3 frames. ` 0 - Indicates that the Receive DS3 Framer block is NOT currently flagging a DS2 Loop-back Request associated with DS2 Channel 6. ` 1 - Indicates that the Receive DS2 Framer block is currently flagging a DS2 Loop-back Request associated with DS2 Channel 6. BIT 5 - Receive DS2 Loop-back Request ON - DS2 Channel 5 See description of BIT6. BIT 4 - Receive DS2 Loop-back Request ON - DS2 Channel 4 See description of BIT6. BIT 3 - Receive DS2 Loop-back Request ON - DS2 Channel 3 See description of BIT6. BIT 2 - Receive DS2 Loop-back Request ON - DS2 Channel 2 See description of BIT6. BIT 1 - Receive DS2 Loop-back Request ON - DS2 Channel 1 See description of BIT6. BIT 0 - Receive DS2 Loop-back Request ON - DS2 Channel 0 See description of BIT6. 233 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 338: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 1 (ADDRESS = 0X0E93) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 3 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 2 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 1 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 0 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 3 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 2 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 1 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 0 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Change of M12 Loop-back Request Condition - DS1 Channel 3 Interrupt Status This RESET-upon-READ bit-field indicates whether or not the M12 De-MUX block (associated with DS2 Channel 0) has generated the Change of M12 Loop-back Request Condition Interrupt, for DS1 Channel 3, since the last read of this register. The M12 De-MUX block will generate this particular interrupt in response to either of the following events. • ? Whenever it detects the M12 Loop-back Request indicator for DS1 Channel 3 (within the incoming DS2 signal) • Whenever it ceases to detect the M12 Loop-back Request indicator for DS1 Channel 3 (within the incoming DS2 signal). ` 0 - Indicates that the Change of M12 Loop-back Request Condition Interrupt, for DS1 Channel 3, has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of M12 Loop-back Request Condition Interrupt, for DS1 Channel 3, has occurred since the last read of this register. BIT6 - Change of M12 Loop-back Request Condition - DS1 Channel 2 Interrupt Status See description of BIT7. BIT 5 - Change of M12 Loop-back Request Condition - DS1 Channel 1 Interrupt Status See description of BIT7. BIT 4 - Change of M12 Loop-back Request Condition - DS1 Channel 0 Interrupt Status See description of BIT7. BIT 3 - Change of M12 Loop-back Request Condition - DS1 Channel 3 Interrupt Enable This READ/WRITE bit-field is used to either enable or disable the Change of M12 Loop-back Request Condition Interrupt for DS1 Channel 3. If this interrupt is enabled, then the XRT86SH328 will generate an interrupt in response to either of the following conditions. • Whenever the M12 De-MUX Block (associated with DS2 Channel 0) detects the M12 Loop-back Request indicator for DS1 Channel 3 (within the incoming DS2 signal). • Whenever the M12 De-MUX Block ceases to detect the M12 Loop-back Request indicator for DS1 Channel 3 (within the incoming DS2 signal). ` 0 - Disables the Change of M12 Loop-back Request Condition Interrupt for DS1 Channel 3. ` 1 - Enables the Change of M12 Loop-back Request Condition Interrupt for DS1 Channel 3. BIT 2 - Change of M12 Loop-back Request Condition - DS1 Channel 2 Interrupt Enable See description of BIT 3. BIT 1 - Change of M12 Loop-back Request Condition - DS1 Channel 1 Interrupt Enable See description of BIT 3. 234 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT 0 - Change of M12 Loop-back Request Condition - DS1 Channel 0 Interrupt Enable See description of BIT 3. TABLE 339: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 1 (ADDRESS = 0X0E94) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 M12 LoopBack Request Status - DS1 Channel 3 M12 LoopBack Request Status - DS1 Channel 2 M12 LoopBack Request Status - DS1 Channel 1 M12 LoopBack Request Status - DS1 Channel 0 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT7 - 4 - Reserved: BIT 3 - M12 Loop-Back Request Status - DS1 Channel 3: This READ/WRITE bit-field indicates whether or not the M12 De-MUX Block (associated with DS2 Channel 0) is currently detecting the M12 Loop-Back Request for DS1 Channel 3, within the incoming DS2 data-stream. ` 0 - Indicates that the M12 De-MUX Block (associated with DS2 Channel 0) is NOT currently detecting the M12 LoopBack Request for DS1 Channel 3, within the incoming DS2 data-stream. ` 1 - Indicates that the M12 De-MUX Block (associated with DS2 Channel 0) is currently detecting the M12 Loop-Back Request for DS1 Channel 3, within the incoming DS2 data-stream. BIT 2 - M12 Loop-Back Request Status - DS1 Channel 2: See description of BIT 3. BIT 1 - M12 Loop-Back Request Status - DS1 Channel 1: See description of BIT 3. BIT 0 - M12 Loop-Back Request Status - DS1 Channel 0: See description of BIT 3. TABLE 340: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 2 (ADDRESS = 0X0E95) BIT7 BIT6 BIT 5 BIT 4 Change of Change of Change of Change of M12 LoopM12 LoopM12 LoopM12 Loopback back back back Request Request Request Request Condition Condition Condition Condition DS1 DS1 DS1 DS1 Channel 7 Channel 6 Channel 5 Channel 4 Interrupt Sta- Interrupt Sta- Interrupt Sta- Interrupt Status tus tus tus BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 7 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 6 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 5 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 4 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 See Table 338 above for bit descriptions, substituting Channel [7:4] for Channel [3:0]. 235 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 341: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 2 (ADDRESS = 0X0E96) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 M12 LoopBack Request Status - DS1 Channel 7 M12 LoopBack Request Status - DS1 Channel 6 M12 LoopBack Request Status - DS1 Channel 5 M12 LoopBack Request Status - DS1 Channel 4 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [7:4] for Channel [3:0]. TABLE 342: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 3 (ADDRESS = 0X0E97) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 11 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 10 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 9 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 8 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 11 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 10 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 9 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 8 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 See Table 338 above for bit descriptions, substituting Channel [11:8] for Channel [3:0]. TABLE 343: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 3 (ADDRESS = 0X0E98) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 M12 LoopBack Request Status - DS1 Channel 11 M12 LoopBack Request Status - DS1 Channel 10 M12 LoopBack Request Status - DS1 Channel 9 M12 LoopBack Request Status - DS1 Channel 8 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [11:8] for Channel [3:0]. 236 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 344: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 4 (ADDRESS = 0X0E99) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 15 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 14 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 13 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 12 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 15 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 14 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 13 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 12 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 See Table 338 above for bit descriptions, substituting Channel [15:12] for Channel [3:0]. TABLE 345: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 4 (ADDRESS = 0X0E9A) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Reserved BIT 2 BIT 1 BIT 0 M12 LoopM12 LoopM12 LoopM12 LoopBack Back Back Back Request Sta- Request Sta- Request Sta- Request Status - DS1 tus - DS1 tus - DS1 tus - DS1 Channel 15 Channel 14 Channel 13 Channel 12 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [15:12] for Channel [3:0]. TABLE 346: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 5 (ADDRESS = 0X0E9B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 19 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 18 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 17 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 16 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 19 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 18 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 17 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 16 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 See Table 338 above for bit descriptions, substituting Channel [19:16] for Channel [3:0]. 237 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 347: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 5 (ADDRESS = 0X0E9C) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 M12 LoopBack Request Status - DS1 Channel 19 M12 LoopBack Request Status - DS1 Channel 18 M12 LoopBack Request Status - DS1 Channel 17 M12 LoopBack Request Status - DS1 Channel 16 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - Bit - See Table 339 above, for bit descriptions, substituting Channel [19:16] for Channel [3:0]. TABLE 348: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 6 (ADDRESS = 0X0E9D) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 23 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 22 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 21 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 20 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 23 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 22 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 21 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 20 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 See Table 338 above for bit descriptions, substituting Channel [23:20] for Channel [3:0]. TABLE 349: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 6 (ADDRESS = 0X0E9E) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 M12 LoopM12 LoopM12 LoopM12 LoopBack Back Back Back Request Sta- Request Sta- Request Sta- Request Status - DS1 tus - DS1 tus - DS1 tus - DS1 Channel 23 Channel 22 Channel 21 Channel 20 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [23:20] for Channel [3:0]. 238 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 350: DS3 FRAMER BLOCK - M12 LOOP-BACK INTERRUPT STATUS/ENABLE REGISTER - 7 (ADDRESS = 0X0E9F) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Change of M12 Loopback Request Condition DS1 Channel 27 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 26 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 25 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 24 Interrupt Status Change of M12 Loopback Request Condition DS1 Channel 27 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 26 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 25 Interrupt Enable Change of M12 Loopback Request Condition DS1 Channel 24 Interrupt Enable RUR RUR RUR RUR R/W R/W R/W R/W 0 0 0 0 0 0 0 0 See Table 338 above for bit descriptions, substituting Channel [27:24] for Channel [3:0]. TABLE 351: DS3 FRAMER BLOCK - M12 LOOP-BACK STATUS REGISTERS - 7 (ADDRESS = 0X0EA0) BIT7 BIT6 BIT 5 BIT 4 Reserved BIT 3 BIT 2 BIT 1 BIT 0 M12 LoopM12 LoopM12 LoopM12 LoopBack Back Back Back Request Sta- Request Sta- Request Sta- Request Status - DS1 tus - DS1 tus - DS1 tus - DS1 Channel 27 Channel 26 Channel 25 Channel 24 R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - See Table 339 above, for bit descriptions, substituting Channel [27:24] for Channel [3:0]. TABLE 352: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA1) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Unused: BIT 5 - DS2 COFA (Change of Framing Alignment) Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the DS2 Change of Framing Alignment interrupt for DS2 Channel # 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt anytime it has detected a change in DS2 framing alignment within the incoming DS2 data-stream. ` 0 - Disables the DS2 COFA Interrupt for DS2 Channel 1. ` 1 - Enables the DS2 COFA Interrupt for DS2 Channel 1. 239 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT 4 - Change of DS2 LOF Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of DS2 LOF Defect Condition Interrupt for DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response to either of the following conditions. • Whenever the M12 De-MUX block declares the DS2 LOF Defect condition, or • Whenever the M12 De-MUX block clears the DS2 LOF Defect condition. ` 0 - Disables the Change of DS2 LOF Defect Condition Interrupt for DS2 Channel 1. ` 1 - Enables the Change of DS2 LOF Defect Condition Interrupt for DS2 Channel 1. BIT 3 - Change of DS2 FERF/RDI Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of DS2 FERF/RDI Defect Condition Interrupt for DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response to either of the following conditions. • Whenever the M12 De-MUX block declares the DS2 FERF/RDI Defect condition, or • Whenever the M12 De-MUX block clears the DS2 FERF/RDI Defect condition. ` 0 - Disables the Change of DS2 FERF/RDI Defect Condition Interrupt for DS2 Channel 1. ` 1 - Enables the Change of DS2 FERF/RDI Defect Condition Interrupt for DS2 Channel 1. BIT 2 - Change of DS2 RED Alarm Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of DS2 RED Alarm Defect Condition Interrupt for DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response to either of the following conditions. • Whenever the M12 De-MUX block declares the DS2 RED Alarm Defect condition, or • Whenever the M12 De-MUX block clears the DS2 RED Alarm Defect condition. ` 0 - Disables the Change of DS2 RED Alarm Defect Condition Interrupt for DS2 Channel 1. ` 1 - Enables the Change of DS2 RED Alarm Defect Condition Interrupt for DS2 Channel 1. BIT 1 - Change of DS2 AIS Defect Condition Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of DS2 AIS Defect Condition Interrupt for DS2 Channel 1. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt in response to either of the following conditions. • Whenever the M12 De-MUX block declares the DS2 AIS Defect condition, or • Whenever the M12 De-MUX block clears the DS2 AIS Defect condition. ` 0 - Disables the Change of DS2 AIS Defect Condition Interrupt for DS2 Channel 1. ` 1 - Enables the Change of DS2 AIS Defect Condition Interrupt for DS2 Channel 1. BIT 0 - Change of State of Reserved Bit (G.747) Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of State of the G.747 Reserved Bit Interrupt. If the user enables this interrupt, then the M12 De-MUX block will generate an interrupt anytime it detects a change of state in the Reserved Bit within the G.747 Data Stream associated with G.747 Channel # 1. ` 0 - Disables the Change of State of the G.747 Reserved Bit Interrupt for M12 De-MUX Block Channel 1. ` 1 - Enables the Change of State of the G.747 Reserved Bit Interrupt for M12 De-MUX Block Channel 1. NOTE: This bit-field is only active if M12 De-MUX Block # 1 has been configured to operate in the G.747 Mode. 240 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 353: DS3 FRAMER BLOCK - DS2 # 1 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA2) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status Change of DS2 FERF/RDI Defect Condition Interrupt Status Change of DS2 RED Alarm Defect Condition Interrupt Status Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:6] - Unused: BIT 5 - DS2 COFA Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the DS2 COFA Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. ` 0 - Indicates that the DS2 COFA Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read of this register. ` 1 - Indicates that the DS2 COFA Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. BIT 4 - Change of DS2 LOF Defect Condition Interrupt Status: This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 LOF Defect Condition interrupt has occurred (within M12 De-MUX # 1) since the last read of this register. ` 0 - Indicates that the Change of DS2 LOF Defect Condition Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS2 LOF Defect Condition Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. BIT 3 - Change of DS2 FERF/RDI Defect Condition Interrupt Status: This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 FERF/RDI Defect Condition interrupt has occurred (within M12 De-MUX # 1) since the last read of this register. ` 0 - Indicates that the Change of DS2 FERF/RDI Defect Condition Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS2 FERF/RDI Defect Condition Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. BIT 2 - Change of DS2 RED Alarm Defect Condition Interrupt Status: This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 RED Alarm Defect Condition interrupt has occurred (within M12 De-MUX # 1) since the last read of this register. ` 0 - Indicates that the Change of DS2 RED Alarm Defect Condition Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS2 RED Alarm Defect Condition Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. BIT 1 - Change of DS2 AIS Defect Condition Interrupt Status: This RESET-upon-READ bit-filed indicates whether or not the Change of DS2 AIS Defect Condition interrupt has occurred (within M12 De-MUX # 1) since the last read of this register. ` 0 - Indicates that the Change of DS2 AIS Defect Condition Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of DS2 AIS Defect Condition Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. BIT 0 - Change of State of Reserved Bit (G.747) Interrupt Status: 241 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This RESET-upon-READ bit-field indicates whether or not the Change of State of the G.747 Reserved Bit Interrupt has occurred (within M12 De-MUX # 1) since the last read of this register. ` 0 - Indicates that the Change of State of the G.747 Reserved Bit Interrupt (associated with M12 De-MUX # 1) has NOT occurred since the last read of this register. ` 1 - Indicates that the Change of State of the G.747 Reserved Bit Interrupt (associated with M12 De-MUX # 1) has occurred since the last read of this register. NOTE: This bit-field is only active if M12 De-MUX Block # 1 has been configured to operate in the G.747 Mode. TABLE 354: DS3 FRAMER BLOCK - DS2 # 1 FRAMER STATUS REGISTER (ADDRESS = 0X0EA3) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:5] - Unused: BIT 4 - DS2 LOF Defect Declared: This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 LOF defect condition. ` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 LOF defect condition. ` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 LOF defect condition. BIT 3 - DS2 FERF/RDI Defect Declared: This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 FERF/RDI defect condition. ` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 FERF/RDI defect condition. ` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 FERF/RDI defect condition. BIT 2 - DS2 RED Alarm Defect Declared: This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 RED Alarm defect condition. ` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 RED Alarm defect condition. ` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 RED Alarm defect condition. BIT 1 - DS2 AIS Defect Declared: This READ-ONLY bit-field indicates whether or not M12 De-MUX Block # 1 is currently declaring the DS2 AIS defect condition. ` 0 - Indicates that M12 De-MUX Block # 1 is NOT currently declaring the DS2 AIS defect condition. ` 1 - Indicates that M12 De-MUX Block # 1 is currently declaring the DS2 AIS defect condition. BIT 0 - Current State of Reserved Bit (G.747): This READ-ONLY bit-field reflects the current state of the G.747 Reserve bit, as relieved by M12 De-MUX Block # 1. 242 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 355: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA4) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 2 for Channel 1 and De-MUx #2 for Demux #1. TABLE 356: DS3 FRAMER BLOCK - DS2 # 2 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA5) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status Change of DS2 FERF/RDI Defect Condition Interrupt Status Change of DS2 RED Alarm Defect Condition Interrupt Status Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 353 above, substituting De-Mux #2 for De-Mux #1. TABLE 357: DS3 FRAMER BLOCK - DS2 # 2 FRAMER STATUS REGISTER (ADDRESS = 0X0EA6) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #2 for De-Mux #1. 243 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 358: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EA7) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 3 for Channel 1 and De-MUx #3 for Demux #1. TABLE 359: DS3 FRAMER BLOCK - DS2 # 3 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EA8) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status Change of DS2 FERF/RDI Defect Condition Interrupt Status Change of DS2 RED Alarm Defect Condition Interrupt Status Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 353 above, substituting De-Mux #3 for De-Mux #1. TABLE 360: DS3 FRAMER BLOCK - DS2 # 3 FRAMER STATUS REGISTER (ADDRESS = 0X0EA9) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #3 for De-Mux #1. 244 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 361: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAA) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 4 for Channel 1 and De-MUx #4 for Demux #1. TABLE 362: DS3 FRAMER BLOCK - DS2 # 4 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAB) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status Change of DS2 FERF/RDI Defect Condition Interrupt Status Change of DS2 RED Alarm Defect Condition Interrupt Status Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 353 above substituting De-Mux #4 for De-Mux #1. TABLE 363: DS3 FRAMER BLOCK - DS2 # 4 FRAMER STATUS REGISTER (ADDRESS = 0X0EAC) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #4 for De-Mux #1. 245 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 364: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EAD) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 5 for Channel 1 and De-MUx #5 for Demux #1. TABLE 365: DS3 FRAMER BLOCK - DS2 # 5 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EAE) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status Change of DS2 FERF/RDI Defect Condition Interrupt Status Change of DS2 RED Alarm Defect Condition Interrupt Status Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 353 above substituting De-Mux #5 for De-Mux #1. TABLE 366: DS3 FRAMER BLOCK - DS2 # 5 FRAMER STATUS REGISTER (ADDRESS = 0X0EAF) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #5 for De-Mux #1. 246 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 367: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB0) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 2 for Channel 6 and De-MUx #6 for Demux #1. TABLE 368: DS3 FRAMER BLOCK - DS2 # 6 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB1) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status Change of DS2 FERF/RDI Defect Condition Interrupt Status Change of DS2 RED Alarm Defect Condition Interrupt Status Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 353 above substituting De-Mux #6 for De-Mux #1. TABLE 369: DS3 FRAMER BLOCK - DS2 # 6 FRAMER STATUS REGISTER (ADDRESS = 0X0EB2) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #6 for De-Mux #1. 247 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 370: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT ENABLE REGISTER (ADDRESS = 0X0EB3) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 COFA Interrupt Enable Change of DS2 LOF Defect Condition Interrupt Enable Change of DS2 FERF/RDI Defect Condition Interrupt Enable Change of DS2 RED Alarm Defect Condition Interrupt Enable Change of DS2 AIS Defect Condition Interrupt Enable Change of State of Reserved Bit (G.747) Interrupt Enable R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 352 above, substituting Channel 7 for Channel 1 and De-MUx #7 for Demux #1. TABLE 371: DS3 FRAMER BLOCK - DS2 # 7 FRAMER INTERRUPT STATUS REGISTER (ADDRESS = 0X0EB4) BIT 7 BIT 6 Unused BIT 5 BIT 4 DS2 COFA Interrupt Status Change of DS2 LOF Defect Condition Interrupt Status BIT 3 BIT 2 Change of Change of DS2 DS2 RED FERF/RDI Alarm Defect Defect Condition Interrupt Condition Status Interrupt Status BIT 1 BIT 0 Change of DS2 AIS Defect Condition Interrupt Status Change of State of Reserved Bit (G.747) Interrupt Status R/O R/O RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 353 above, substituting De-Mux #7 for De-Mux #1. TABLE 372: DS3 FRAMER BLOCK - DS2 # 7 FRAMER STATUS REGISTER (ADDRESS = 0X0EB5) BIT 7 BIT 6 BIT 5 Unused BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DS2 LOF Defect Declared DS2 FERF/RDI Defect Declared DS2 RED Alarm Defect Declared DS2 AIS Defect Declared Current State of Reserved Bit (G.747) R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT [7:0] - For bit descriptions see Table 354 above, substituting De-Mux #7 for De-Mux #1. 248 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 373: DS3 FRAMER BLOCK - M13 DE-MUX REGISTER (ADDRESS = 0X0EB8) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Auto DS1/E1 AIS upon DS2 OOF Defect Unused Auto DS1/E1 AIS upon DS2 AIS Defect Unused R/O R/O R/O R/O R/W R/O R/W R/O 0 0 0 0 0 0 0 0 BIT [7:4] - Unused: BIT 3 - Auto DS1/E1 AIS upon DS2 LOF Defect: This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (associated with a given M12 De-MUX block) to automatically transmit the DS1/E1 AIS indicator via each of its three or four downstream DS1/E1 signals, anytime (and for the duration that) the corresponding M12 De-MUX block declares the DS2 LOF defect condition. ` 0 - Does not configure each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream DS1/E1 signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 LOF defect condition. ` 1 - Configures each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream DS1/E1 signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 LOF defect condition. NOTE: This bit-setting applies to each of the seven (7) M12 De-MUX blocks within the XRT86SH328. BIT 2 - Unused: BIT 1 - Auto DS1/E1 AIS upon DS2 AIS Defect: This READ/WRITE bit-field is used to configure all of the Egress Direction Transmit DS1/E1 Framer blocks (associated with a given M12 De-MUX block) to automatically transmit the DS1/E1 AIS indicator via each of its three or four downstream DS1/E1 signals, anytime (and for the duration that) the corresponding M12 De-MUX block declares the DS2 AIS defect condition. ` 0 - Does not configure each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream DS1/E1 signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 AIS defect condition. ` 1 - Configures each of the M12 De-MUX blocks to force all of its corresponding Egress Direction Transmit DS1/E1 Framer blocks (within the XRT86SH328) to automatically transmit the DS1/E1 AIS indicator via its downstream DS1/E1 signals, anytime (and for the duration that) the M12 De-MUX block declares the DS2 AIS defect condition. NOTE: This bit-setting applies to each of the seven (7) M12 De-MUX blocks within the XRT86SH328328. BIT 0 - Unused: 2.12 T1/E1 LIU CHANNEL CONTROL REGISTERS • (N ranges from 0x01 to 0x1C) TABLE 374: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN000) BIT7 BIT6 BIT 5 BIT 4 BIT 3 PRBS/QRSS PRBS_Rx_Tx RXON R/W R/W R/W R/W R/W 0 0 0 0 0 BIT 2 BIT 1 BIT 0 R/W R/W R/W 0 0 0 EQC[4:0] BIT7 - PRBS/QRSS: These bits are used to select between QRSS and PRBS. To send the a QRSS or PRBS pattern, the TxTEST[2:0] bits in register 0xN002h must be programmed. 249 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 0 = QRSS ` 1 = PRBS BIT6 - PRBS/QRSS Direction Select Rx/Tx: This bit is used to select which direction is used to send the PRBS/QRSS pattern if enabled within the TxTEST[2:0] bits in register 0xN002h. ` 0 = Line Interface (Ttip/Tring) ` 1 = System Side Interface (Clock/Data) BIT 5 - RXON Receiver Enable: This bit is used enable the receiver line interface. By default, the receivers are turned off to support redundancy. ` 0 = Disabled. ` 1 = Enabled. BIT [4:0] - Equalizer Control and Line Build Out: These bits are used to select the equalizer control and line build out. Selection Chart for Equalizer Control and Line Build-Out EQC[4:0] T1/E1 MODE RECEIVE SENSITIVITY TRANSMIT LBO CABLE CODING 01000 T1 Short Haul 0 - 133 Ft (0.6dB) 100W TP B8ZS 01001 T1 Short Haul 0 - 133 Ft (0.6dB) 100W TP B8ZS 01010 T1 Short Haul 0 - 133 Ft (0.6dB) 100W TP B8ZS 01011 T1 Short Haul 0 - 133 Ft (0.6dB) 100W TP B8ZS 01100 T1 Short Haul 0 - 133 Ft (0.6dB) 100W TP B8ZS 01101 T1 Short Haul Arbitrary Pulse 100W TP B8ZS 11100 E1 Short Haul ITU G.703 75W Coax HDB3 11101 E1 Short Haul ITU G.703 120W TP HDB3 TABLE 375: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN001) BIT7 BIT6 BIT 5 BIT 4 BIT 3 RxTSEL TxTSEL R/W R/W R/W R/W R/W 0 0 0 0 0 TERSEL[1:0] BIT 2 BIT 1 BIT 0 JABW FIFOS R/W R/W R/W 0 0 0 JASEL[1:0] BIT7 - RxTSEL: This bit is used for the receive line interface to select between Internal (automatic line impedance) and External (high impedance) modes. ` 0 = External Impedance ` 1 = Internal Impedance BIT6 - TxTSEL: This bit is used for the transmit line interface to select between Internal (automatic line impedance) and External (high impedance) modes. ` 0 = External Impedance ` 1 = Internal Impedance BIT [5:4] - TERSEL[1:0]: 250 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS These bits are used to select the line impedance for internal termination control. ` 00 = 100W ` 01 = 110W ` 10 = 75W ` 11 = 120W BIT [3:2] - JASEL[1:0]: These bits are used to select which path the Jitter Attenuator is placed. ` 00 = Disabled. ` 01 = Transmit Line Interface Path ` 10 = Receive Line Interface Path ` 11 = Receive Line Interface Path ` BIT 1 - Jitter Attenuator Band Width: The jitter band width is a global setting that is applied in both transmit and receive directions. ` 0 = 10 Hz ` 1 = 1.5 Hz BIT 0 - First In First Out Bit Depth: This bit is used for the transmit line interface to select between Internal (automatic line impedance) and External (high impedance) modes. ` 0 = 32-Bit ` 1 = 64-Bit TABLE 376: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN002) BIT7 BIT6 INVQRSS BIT 5 BIT 4 BIT 3 TxTEST[2:0] BIT 2 TXON BIT 1 BIT 0 LOOP[2:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Invert QRSS: INVQRSS is used to invert the transmit QRSS pattern set by the TxTEST[2:0] bits. By default, INVQRSS is disabled and the QRSS will be transmitted with normal polarity. ` 0 = External Impedance ` 1 = Internal Impedance BIT [6:4] - Tx Test Pattern [2:0]: These bits are used to select a Test Pattern to be sent to the transmit line interface. If bit 6 in register 0xN000h is set High, then the Test Pattern will be sent out on the receive DS-1/E1 system side. ` 0XX = No Test Pattern ` 100 = Tx QRSS ` 101 = Tx TAOS ` 110 = Reserved ` 111 = Reserved BIT 3 - TXON Transmitter Enable: This bit is used enable the transmitter line interface. By default, the transmitters are turned off to support redundancy. ` 0 = Disabled. ` 1 = Enabled. BIT [2:0] - Loop Back Mode Select [2:0]: 251 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 These bits are used to select a loop back mode for diagnostic testing. These bits only represent the loop back modes supported in the LIU section of Voyager. For other loop back mode options, see the register map in other modes of operation. ` 0XX = No Loop Back ` 100 = Dual Loop Back ` 101 = Analog Loop Back ` 110 = Remote Loop Back ` 111 = Digital Loop Back TABLE 377: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN003) BIT7 BIT6 RxRES[1:0] BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CODES Reserved E1ARBIT INSBPV INSBER Reserved R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Receiver Fixed External Termination: RxRES[1:0] are used to select the value for a high precision external resistor to improve return loss. ` 00 = None ` 01 = 240W ` 10 = 210W ` 11 = 150W BIT 5 - CODES Encoding / Decoding Select: This bit is used to select the type of encoding/decoding the transmitter and receiver will generate/process. ` 0 = HDB3 (E1), B8ZS (T1) ` 1 = AMI Coding BIT 4 - Reserved: BIT 3 - E1Arbitrary Pulse Select: This bit is used to enable the Arbitrary Pulse Generator for shaping the transmit pulse when E1 mode is selected. ` 0 = Disabled (Normal E1 Pulse Shape ITU G.703) ` 1 = Arbitrary Pulse Enabled BIT 2 - Insert Bipolar Violation: When this bit transitions from Low to High, a bipolar violation will be inserted in the transmitted data from TPOS, QRSS/PRBS pattern. The state of this bit will be sampled on the rising edge of TCLK. To ensure proper operation, it is recommended to write a 0 to this bit before writing a 1. ` 0 to 1 Transition = Insert one bipolar violation BIT 1 - Insert Bit Error: When this bit transitions from Low to High, a bit error will be inserted in the transmitted QRSS/PRBS pattern. The state of this bit will be sampled on the rising edge of TCLK. To ensure proper operation, it is recommended to write a 0 to this bit before writing a 1. ` 0 to 1 Transition = Insert one bit error BIT 0 - Reserved: 252 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 378: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN004) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DMOIE FLSIE LCVIE Reserved AISDIE RLOSIE QRPDIE R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT6 - Digital Monitor Output Interrupt Enable: ` 0 = Masks the DMO function ` 1 = Enables interrupt generation for DMO BIT 5 - FIFO Limit Status Interrupt Enable: ` 0 = Masks the FLS function ` 1 = Enables interrupt generation for FLS BIT 4 - Line Code Violation Interrupt Enable: ` 0 = Masks the LCV function ` 1 = Enables interrupt generation for LCV BIT 3 - Reserved: BIT 2 - Alarm Indication Signal Interrupt Enable: ` 0 = Masks the AIS function ` 1 = Enables interrupt generation for AIS BIT 1 - Receive Loss of Signal Interrupt Enable: ` 0 = Masks the RLOS function ` 1 = Enables interrupt generation for RLOS BIT 0 - Quasi Random Pattern Detection Interrupt Enable: ` 0 = Masks the QRPD function ` 1 = Enables interrupt generation for QRPD TABLE 379: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN005) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DMO FLS LCV Reserved AISD RLOS QRPD RO RO RO RO RO RO RO RO 0 0 0 0 0 0 0 0 BIT6 - Digital Monitor Output: This bit indicates the DMO activity. An interrupt will not occur unless the DMOIE is set High in register 0xN004h and the global interrupt enable has been set. ` 0 = No Alarm ` 1 = Transmit output driver has failures BIT 5 - FIFO Limit Status: This bit indicates whether the RD/WR pointers are within 3-Bits. An interrupt will not occur unless the FLSIE is set High in register 0xN004h and the global interrupt enable has been set. ` 0 = No Alarm ` 1 = RD/WR FIFO pointers are within ±3-Bits BIT 4 - Line Code Violation: 253 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 This bit serves a dual purpose. By default, this bit monitors the line code violation activity. However, if bit 7 in register 0x0101h is set High, this bit monitors the overflow status of the internal LCV counter. An interrupt will not occur unless the LCV/OFIE is set High in register 0xN004h and the global interrupt enable has been set. ` 0 = No Alarm ` 1 = A line code violation, bipolar violation, or excessive zeros has occurred BIT 3 - Reserved: BIT 2 - Alarm Indication Signal: This bit indicates the AIS activity. An interrupt will not occur unless the AISIE is set High in register 0xN004h and the global interrupt enable has been set. ` 0 = No Alarm ` 1 = An all ones signal is detected BIT 1 - Receive Loss of Signal: This bit indicates the RLOS activity. An interrupt will not occur unless the RLOSIE is set High in register 0xN004h and the global interrupt enable has been set. ` 0 = No Alarm ` 1 = An RLOS condition is present BIT 0 - Quasi Random Pattern Detection: This bit indicates that a QRPD has been detected. An interrupt will not occur unless the QRPDIE is set High in register 0xN004h and the global interrupt enable has been set. ` 0 = No Alarm ` 1 = A QRP is detected TABLE 380: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN006) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved DMOIS FLSIS LCVIS Reserved AISDIS RLOSIS QRPDIS RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 NOTE: These register bits are Reset Upon Read. They will be set High anytime a change in status occurs. Once these bits are read back, they will automatically be set Low. BIT7 - Reserved: BIT6 - Digital Monitor Output Interrupt Enable: ` 0 = No change ` 1 = Change in status occurred BIT 5 - FIFO Limit Status Interrupt Enable: ` 0 = No change ` 1 = Change in status occurred BIT 4 - Line Code Violation Interrupt Enable: ` 0 = No change ` 1 = Change in status occurred BIT 3 - Reserved: BIT 2 - Alarm Indication Signal Interrupt Enable: ` 0 = No change ` 1 = Change in status occurred BIT 1 - Receive Loss of Signal Interrupt Enable: ` 0 = No change 254 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 1 = Change in status occurred BIT 0 - Quasi Random Pattern Detection Interrupt Enable: ` 0 = No change ` 1 = Change in status occurred TABLE 381: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN007) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 ENROM Reserved Reserved RSTALL UPDATEALL HI/LO UPDATE RST R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Enable ROM for LCV Counter: This bit is used to enable data from an internal LCV counter to be read back. ` 0 = Disabled. ` 1 = Enabled. BIT [6:5] - Reserved: BIT 4 - Reset All Internal LCV Counters: This bit is used to reset all 28 Internal LCV counters to their default state 0000h. This bit must be set High for a minimum of 1mS. ` 0 = Normal Operation ` 1 = Resets All LCV Counters BIT 3 - Update All LCV Counters: This bit is used to latch the contents of all 28 internal LCV counters so that the values can be read. When the HI/LO bit is set Low, initiating this update bit places the lower 8 bits of the 16-bit word in register 0xN011h. When the HI/LO bit is set High, initiating this update bit places the upper 8 bits of the 16-bit word in register 0xN010h. ` 0 = Normal Operation ` 1 = Updates All LCV Counters BIT 2 - High Byte / Low Byte Select: This bit is used to select which byte of the 16-bit LCV value will be placed in the read back registers. ` 0 = Lower Byte LCV[7:0] ` 1 = Upper Byte LCV[15:8] BIT 1 - Update LCV Counter: This bit is used to latch the contents of the internal LCV counter for this channel so that the value can be read. When the HI/LO bit is set Low, initiating this update bit places the lower 8 bits of the 16-bit word in register 0xN011h. When the HI/LO bit is set High, initiating this update bit places the upper 8 bits of the 16-bit word in register 0xN010h. ` 0 = Normal Operation ` 1 = Update LCV Counter BIT 0 - Reset Internal LCV Counter: This bit is used to reset the Internal LCV for this channel to its default state 0000h. This bit must be set High for a minimum of 1mS. ` 0 = Normal Operation ` 1 = Reset LCV Counter 255 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 382: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN008) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S1 B5S1 B4S1 B3S1 B2S1 B1S1 B0S1 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 1: The transmit output pulse is divided into 8 individual segments. This register is used to program the first segment which corresponds to the overshoot of the pulse amplitude. There are four segments for the top portion of the pulse and four segments for the bottom portion of the pulse. Segment number 5 corresponds to the undershoot of the pulse. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction TABLE 383: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN009) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S2 B5S2 B4S2 B3S2 B2S2 B1S2 B0S2 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 2: The transmit output pulse is divided into 8 individual segments. This register is used to program the second segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction TABLE 384: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00A) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S3 B5S3 B4S3 B3S3 B2S3 B1S3 B0S3 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 3: The transmit output pulse is divided into 8 individual segments. This register is used to program the Third segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction 256 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 385: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00B) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S4 B5S4 B4S4 B3S4 B2S4 B1S4 B0S4 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 4: The transmit output pulse is divided into 8 individual segments. This register is used to program the Fourth segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction TABLE 386: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S5 B5S5 B4S5 B3S5 B2S5 B1S5 B0S5 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 5: The transmit output pulse is divided into 8 individual segments. This register is used to program the Fifth segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction TABLE 387: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00D) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S6 B5S6 B4S6 B3S6 B2S6 B1S6 B0S6 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 6: The transmit output pulse is divided into 8 individual segments. This register is used to program the Sixth segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction 257 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 388: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00E) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S7 B5S7 B4S7 B3S7 B2S7 B1S7 B0S7 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 7: The transmit output pulse is divided into 8 individual segments. This register is used to program the Seventh segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction TABLE 389: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN00F) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved B6S8 B5S8 B4S8 B3S8 B2S8 B1S8 B0S8 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved: BIT [6:0] - Arbitrary Pulse Generation Segment 8: The transmit output pulse is divided into 8 individual segments. This register is used to program the Eighth segment of the pulse amplitude. The MSB of each segment is the sign bit. • If Sign Bit (BIT6) =: ` 0 - Negative Direction ` 1 - Positive Direction TABLE 390: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN010) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LCVHI7 LCVHI6 LCVHI5 LCVHI4 LCVHI3 LCVHI2 LCVHI1 LCVHI0 RO RO RO RO RO RO RO RO 0 0 0 0 0 0 0 0 BIT [7:0] - Internal LCV Counter High Byte: Once the internal LCV counter has been enabled and updated, these bits contain the upper byte of the 16-bit LCV counter word. 258 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 391: LIU CHANNEL CONTROL REGISTER 0 (ADDRESS = 0XN011) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LCVLO7 LCVLO6 LCVLO5 LCVLO4 LCVLO3 LCVLO2 LCVLO1 LCVLO0 RO RO RO RO RO RO RO RO 0 0 0 0 0 0 0 0 BIT [7:0] - Internal LCV Counter Low Byte: Once the internal LCV counter has been enabled and updated, these bits contain the lower byte of the 16-bit LCV counter word. 2.13 DS1/E1 FRAMER BLOCK REGISTERS - DS1 APPLICATIONS The register map for the DS1/E1 Framer blocks (for DS1 Applications) is presented in the Table below. Additionally, a detailed description of each of the DS1/E1 Framer Block register is presented below. NOTE: The register map/description for the DS1/E1 Framer blocks (for E1 Applications) is presented in Section _. In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328 device, with both the Ingress and Egress Direction Transmit/Receive DS1/E1 Framer blocks highlighted is presented below in Figure 17.. FIGURE 17. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE TRANSMIT/RECEIVE DS1/E1 FRAMER BLOCKS HIGHLIGHTED STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 SOME COMMENTS ABOUT ADDRESSING DS1/E1 FRAMER BLOCK REGISTERS 259 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Throughout the XRT86SH328 Data Sheet, the user can control/monitor the function/performance of the T1/E1 Framer blocks consists of the following sets of Registers. • Channel Control Registers • Receive Signaling Array Registers • LAPD Buffer 0 Data Registers • LAPD Buffer 1 Data Registers • Channel - Framer Performance Monitor Registers • Channel - Framer Interrupt Register In the XRT86SH328 Data Sheet, we indicate that the following sets of Register have the following Address Locations. TABLE 392: MEMORY MAP - T1/E1 FRAMER BLOCK ADDRESS LOCATION REGISTER SET 0xN100 - 0xN1FF Channel X - Control Registers 0xN200 - 0xN2FF Reserved 0xN300 - 0xN3FF Channel X - Channel Control Registers 0xN400 - 0xN4FF Reserved 0xN500 - 0xN5FF Channel X - Receive Signaling Array Registers 0xN600 - 0xN6FF Channel X - LAPD Buffer 0 Data Register 0xN700 - 0xN7FF Channel X - LAPD Buffer 1 Data Register 0xN800 - 0xN8FF Reserved 0xN900 - 0xN9FF Channel X - Framer Performance Monitor Registers 0xNA00 - 0xNAFF Reserved 0xNB00 - 0xNBFF Channel X - Framer Interrupt Registers NOTE: The XRT86SH328 has a total of 28 Ingress Direction Transmit/Receive DS1/E1 Framer blocks and 28 Egress Direction Transmit/Receive DS1/E1 Framer Blocks. Hence, the XRT86SH328 device contains a total of 56 Transmit/Receive DS1/E1 Framer blocks. Therefore, in Table _-1, the value of N can range in value from 0x01 to 0x38. OBVIOUS QUESTION: What value of N pertains to which of the 56 T1/E1 Framer blocks within the chip? The answer to this question depends upon whether the XRT86SH328 has been configured to operate in the VT-Mapper (with T1/E1 Framing) or in the M13 MUX (with T1/E1 Framing) Mode. Table 393 and Table 394 present the values for N (for each T1/E1 Framer block) as a function of Channel Number and Signal Direction for VT- Mapper (with T1/E1 Framing) and M13 MUX (with T1/E1 Framing) applications, respectively. Further, Figure 18 (which depicts an illustration of the various T1/E1 Framer blocks within a given channel) can be used as a point of reference when looking at Table 393 and Table 394. 260 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 18. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE WITH BOTH THE INGRESS AND EGRESS DIRECTION T1/E1 FRAMER BLOCKS (OF A GIVEN T1/E1 CHANNEL) HIGHLIGHTED STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 TABLE 393: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - VT-MAPPER (WITH T1/E1 FRAMING) MODE APPLICATIONS INGRESS DIRECTION EGRESS DIRECTION CHANNEL NUMBER RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK 1 0x1D 0x01 0x01 0x1D 2 0x1E 0x02 0x02 0x1E 3 0x1F 0x03 0x03 0x1F 4 0x20 0x04 0x04 0x20 5 0x21 0x05 0x05 0x21 6 0x22 0x06 0x06 0x22 7 0x23 0x07 0x07 0x23 8 0x24 0x08 0x08 0x24 9 0x25 0x09 0x09 0x25 261 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 393: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - VT-MAPPER (WITH T1/E1 FRAMING) MODE APPLICATIONS INGRESS DIRECTION EGRESS DIRECTION CHANNEL NUMBER RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK 10 0x26 0x0A 0x0A 0x26 11 0x27 0x0B 0x0B 0x27 12 0x28 0x0C 0x0C 0x28 13 0x29 0x0D 0x0D 0x29 14 0x2A 0x0E 0x0E 0x2A 15 0x2B 0x0F 0x0F 0x2B 16 0x2C 0x10 0x10 0x2C 17 0x2D 0x11 0x11 0x2D 18 0x2E 0x12 0x12 0x2E 19 0x2F 0x13 0x13 0x2F 20 0x30 0x14 0x14 0x30 21 0x31 0x15 0x15 0x31 22 0x32 0x16 0x16 0x32 23 0x33 0x17 0x17 0x33 24 0x34 0x18 0x18 0x34 25 0x35 0x19 0x19 0x35 26 0x36 0x1A 0x1A 0x36 27 0x37 0x1B 0x1B 0x37 28 0x38 0x1C 0x1C 0x38 TABLE 394: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - M13 MUX (WITH T1/E1 FRAMING) MODE APPLICATIONS INGRESS DIRECTION EGRESS DIRECTION CHANNEL NUMBER RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK 1 0x01 0x1D 0x1D 0x01 2 0x02 0x1E 0x1E 0x02 3 0x03 0x1F 0x1F 0x03 4 0x04 0x20 0x20 0x04 5 0x05 0x21 0x21 0x05 6 0x06 0x22 0x22 0x06 262 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 394: RELATIONSHIP BETWEEN VALUE OF N AND CHANNEL NUMBER, SIGNAL DIRECTION - M13 MUX (WITH T1/E1 FRAMING) MODE APPLICATIONS INGRESS DIRECTION EGRESS DIRECTION CHANNEL NUMBER RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK RECEIVE DS1/E1 FRAMER BLOCK TRANSMIT DS1/E1 FRAMER BLOCK 7 0x07 0x23 0x23 0x07 8 0x08 0x24 0x24 0x08 9 0x09 0x25 0x25 0x09 10 0x0A 0x26 0x26 0x0A 11 0x0B 0x27 0x27 0x0B 12 0x0C 0x28 0x28 0x0C 13 0x0D 0x29 0x29 0x0D 14 0x0E 0x2A 0x2A 0x0E 15 0x0F 0x2B 0x2B 0x0F 16 0x10 0x2C 0x2C 0x10 17 0x11 0x2D 0x2D 0x11 18 0x12 0x2E 0x2E 0x12 19 0x13 0x2F 0x2F 0x13 20 0x14 0x30 0x30 0x14 21 0x15 0x31 0x31 0x15 22 0x16 0x32 0x32 0x16 23 0x17 0x33 0x33 0x17 24 0x18 0x34 0x34 0x18 25 0x19 0x35 0x35 0x19 26 0x1A 0x36 0x36 0x1A 27 0x1B 0x37 0x37 0x1B 28 0x1C 0x38 0x38 0x1C TABLE 395: T1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Unused Set T1 Mode Force all Channels to Sync to 8kHz R/O R/W R/W R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 1 Unused BIT7 - Reserved 263 BIT 1 BIT 0 Clock Source Select[1:0] PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT6 - Set T1 Mode: This READ/WRITE bit-field is used to configure the Channel to operate in either the T1 or E1 Mode. ` 0 - Configures the Framer Channel to operate in the E1 Mode ` 1 - Configures the Framer Channel to operate in the T1 Mode BIT 5 - Force all Channels to Sync to 8kHz: This READ/WRITE bit-field is used to configure all active (either 28 or 56) Transmit DS1 Framer blocks to synchronize their transmit output frame alignment with the 8kHz signal that is derived from the MCLK PLL. ` 0 - Does not configure each of the Transmit DS1 Framer blocks to synchronize their transmit output frame alignment with the 8kHz signal (from the MCLK PLL). ` 1 - Configures each of the Transmit DS1 Framer blocks to synchronize their transmit output frame alignment with the 8kHz signal (from the MCLK PLL). NOTE: This feature should only be used if the XRT86SH328 has been configured to operate in the 28-Channel DS1 Framer/LIU Combo Mode. The user MUST NOT use this feature if the XRT86SH328 has been configured to operate in any of the Aggregation Modes. BIT [4:2] - Reserved BIT [1:0] - Clock Source Select[1:0]: These two READ/WRITE bit-fields is used to specify the timing source for the Ingress and Direction Transmit DS1 Framer block, within this particular channel. The Relationship between the Clock Source Select[1:0] bit-fields and the resulting timing source for the Transmit DS1 Framer block, within this particular Channel CLOCK SOURCE SELECT[1:0] TIMING SOURCE FOR TRANSMIT DS1 FRAMER BLOCK 00 Loop-Timing Mode:The Transmit DS1 Framer block will derive its timing from the Received or Recovered Clock signal within the corresponding Receive DS1 Framer block.NOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 28-Channel DS1 Framer/LIU Combo Mode 01 Local-Timing Mode (TxDS1CLK_n Input)The Transmit DS1 Framer block will either use up-stream timing or the TxDS1CLK_n input as its timing source.NOTE: For Aggregation Applications, the user MUST configure all active DS1 Framer blocks to operate in this timing mode. 10 Local-Timing Mode (MCLK PLL Input)The Transmit DS1 Framer block will derive its timing from the MCLK PLL.NOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 28-Channel DS1 Framer/LIU Combo Mode. 11 Loop-Timing ModeThe Transmit DS1 Framer block will derive its timing from the Received or Recovered Clock signal within the corresponding Receive DS1 Framer blockNOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 28-Channel DS1 Framer/LIU Combo Mode. TABLE 396: T1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Transmit LOS Pattern Reserved R/W R/O R/W R/W R/O 0 1 0 0 0 BIT 2 BIT 1 BIT 0 R/O R/O R/O 0 0 0 Framer Loop-Back[1:0] Reserved 264 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT7 - Transmit LOS Pattern: This READ/WRITE bit-field configures the Transmit DS1 Framer block to generate and transmit the LOS Pattern to the remote terminal. ` 0 - Configures the Transmit DS1 Framer Block to transmit normal DS1 traffic ` 1 - Configures the Transmit DS1 Framer Block to transmit the LOS pattern. NOTE: The user MUST set this bit-field to 0 for Normal Operation. BIT6 - Reserved: BIT [5:4] - Framer Loop-back[1:0]: These two READ/WRITE bit-fields are used to configure the Transmit/Receive DS1 Framer blocks to operate in a variety of possible loop-back modes, as depicted in the Table below. Relationship between the Framer Loop-back[1:0] bit-fields and the Corresponding Loop-Back Mode within the DS1 Framer block FRAMER LOOP-BACK[1:0] RESULTING LOOP-BACK MODE (WITHIN FRAMER BLOCK) 00 Normal Operation (No Loop-back) Mode 01 Local Loop-back Mode 10 Remote Loop-back Mode 11 Reserved TABLE 397: T1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Signaling Update on Super Frame Boundaries Force CRC Errors Set J1 Mode One & Only Fast Sync R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 DS1 Framing Format Select[2:0] BIT7 - Signaling Update on Super Frame Boundaries: This READ/WRITE bit-field is used to either enable or disable Signaling Update on Super-Frame Boundaries, in both the Transmit and Receive Directions, as described below. In the Receive Direction If the user enables this feature, then signaling data will update (via the Receive Signaling Array Registers) only upon the Super-Frame Boundaries. If the user does NOT to enable this feature, then signaling data will be updated (within the Receive Signaling Array Registers) as soon as they are received within the incoming DS1 data-stream. In the Transmit Direction If the user enables this feature, then any signaling data that occur (within the Transmit Output DS1 data-stream) will be updated upon the Super-Frame boundaries. If the user does NOT to enable this feature, then signaling data (within the outbound DS1 data-stream) will be updated as soon as it is changed. ` 0 = Disables the Signaling Update on Super-Frame Boundaries features. ` 1 = Enables the Signaling Update on Super-Frame Boundaries features. BIT6 - Force CRC Errors: This READ/WRITE bit-field is used to force the Transmit DS1 Framer block to transmit CRC errors within the outbound DS1 data-stream. ` 0 = Configures the Transmit DS1 Framer block to transmit DS1 data with correct CRC values 265 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 1 = Configures the Transmit DS1 Framer block to transmit DS1 data with erred CRC values. NOTE: The Transmit DS1 Framer block will transmit DS1 data, with erred CRC values, for the duration that this bit-field is set to 1. BIT 5 - Set J1 Mode: This READ/WRITE bit-field, along with BIT6 (Set T1 Mode) within the T1/E1 Framer Block - Clock Select Register (Address = 0xN100) is used to configure the Channel to operate in the J1 Mode. The Relationship between the States of the Set T1 Mode and the Set J1 Mode bit-fields and the Corresponding Mode of Channel SET J1 MODE SET T1 MODE (BIT6 IN 0XN100) OPERATING MODE OF CHANNEL 0 0 E1 Mode 0 1 T1 Mode 1 0 E1 Mode 1 1 J1 Mode BIT 4 - One & Only: BIT 3 - Fast Sync: BIT [2:0] - DS1 Framing Format Select[2:0]: These three READ/WRITE bit-fields is used to select the Framing format that the DS1 Framer Channel will operate ini. The Relationship between the state of the DS1 Framing Format Select[2:0] bits and the resulting Framing format of the channel DS1 FRAMING FORMAT SELECT[2:0] RESULTING FRAMING FORMAT 0XX DS1, ESF - Extended Super-Frame 100 Do Not Use 101 DS1, SF - Super-Frame 11X Do Not Use TABLE 398: T1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Yellow Alarm - One Second Rule Transmit Yellow Alarm R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Yellow Alarm Format[1:0] BIT 2 Transmit AIS Pattern Select[1:0] BIT 1 BIT 0 AIS Defect Declaration Criteria[1:0] BIT7 - Yellow Alarm - One Second Rule: This READ/WRITE bit-field is used to configure the Transmit DS1 Framer to transmit the RAI (or Yellow Alarm) indicator per the One Second Rule (as described in the ANSI standards). Transmission of the RAI Indicator per the One Second Rule If the user invokes the One Second Rule, then the following will happen. • Whenever the Transmit DS1 Framer block generates and transmits the RAI indicator, it will do so for at least one second (for both the ESF and the SF framing formats) 266 PRELIMINARY REV. P1.0.6 • XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS The Transmit DS1 Framer block will insure that there is a minimum of a one-second delay between the time that it terminates transmission of the RAI indicator, and the instant that it proceeds to transmit the RAI indicator again. Transmission of the RAI Indicator when the One Second Rule is NOT in-force If the user does NOT invoke the One Second Rule, then the following will happen. • Whenever the Transmit DS1 Framer block generates and transmits the RAI indicator, it will do so for at least one second (for both the ESF and the SF framing formats). • The Transmit DS1 Framer block will NOT insure that there is a minimum of a one-second delay between the time that it terminates transmission of the RAI indicator, and the instant that it proceeds to transmit the RAI indicator again. ` 0 = Does not configure the Transmit DS1 Framer block to transmit the RAI indicator per the One Second Rule. ` 1 = Configures the Transmit DS1 Framer block to transmit the RAI indicator per the One Second Rule. BIT6 - Transmit Yellow Alarm: BIT [5:4] - Yellow Alarm Format[1:0]: BIT [3:2] - Transmit AIS Pattern Select[1:0]: These two READ/WRITE bit-fields serves the following two functions. • To command the Transmit DS1 Framer block to transmit the AIS indicator (per Software Command), and • To specify the type of AIS Pattern that the Transmit DS1 Framer block will transmit, whenever it has been commanded to transmit the AIS indicator to the remote terminal equipment. The Relationship between Transmit AIS Pattern Select[1:0] and the resulting behavior of the Transmit DS1 Framer block TRANSMIT AIS PATTERN SELECT[1:0] TRANSMIT DS1 FRAMER BLOCK ACTION 00/10 Transmits Normal TrafficTransmit DS1 Framer block does not transmit the AIS indicator. It will (instead) transmit normal traffic 01 Unframed All Ones PatternThe Transmit DS1 Framer block will transmit an Unframed All Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [0, 1]. 11 Framed All Ones PatternThe Transmit DS1 Framer block will transmit a Framed All Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [1, 0]. BIT [1:0] - AIS Defect Declaration Criteria[1:0]: These two READ/WRITE bit-fields are used to select the type of AIS Pattern that the Receive DS1 Framer block will look for in order to determine whether or not it should declare or clear the AIS defect condition The Relationship between AIS Defect Declaration Criteria[1:0] and the resulting AIS Pattern that the Receive DS1 Framer block will look for in declaring/clearing the AIS defect condition AIS DEFECT DECLARATION CRITERIA[1:0] 00/10 RECEIVE DS1 FRAMER BLOCK - AIS DEFECT DECLARATION CRITERIA AIS Defect Declaration is DisabledThe Receive DS1 Framer block will NOT declare the AIS defect condition at all. 01 Unframed and Framed All Ones Pattern:The Receive DS1 Framer block will declare the AIS defect condition whenever it receives either the Framed or Unframed All Ones pattern for at least 42ms. 11 Framed All Ones Pattern:The Receive DS1 Framer block will only declare the AIS defect condition whenever it receives the Framed All Ones Pattern for at least 42ms. 267 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 399: T1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 CRC-6 Source Select Framing Bits Source Select R/O R/W R/W R/W R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:2] - Reserved BIT 1 - CRC-6 Source Select: This READ/WRITE bit-field is used to specify the source of the CRC-6 bits, within the outbound DS1 data-stream. ` 0 = Configures the Transmit DS1 Framer block to internally compute and insert the CRC-6 bits within the outbound DS1 data-stream. ` 1 = Configures the Transmit DS1 Framer block to externally accept data from the TxDS1DATA_n input pin (or from upstream circuitry) and to insert this data into the CRC-6 bit-fields within the outbound DS1 data-stream. BIT 0 - Framing Bits Source Select: This READ/WRITE bit-field is used to specify the source of the Framing bits, within the outbound DS1 data-stream. ` 0 = Configures the Transmit DS1 Framer block to internally generate and insert the Framing bits within the outbound DS1 data-stream ` 1 = Configures the Transmit DS1 Framer block to externally accept data from the TxDS1DATA_n input pin (or from upstream circuitry) and to insert this data into the Framing bit-fields within the outbound DS1 data-stream. TABLE 400: T1 FRAMER BLOCK - TRANSMIT DATA LINK SELECT REGISTER (ADDRESS = 0XN10A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 Reserved BIT 5 BIT 4 Transmit Data Link Bandwidth[1:0] BIT 3 BIT 2 Transmit D/E Time Source Select[1:0] BIT 1 BIT 0 Transmit Data Link Source Select[1:0] R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Reserved: BIT [5:4] - Transmit Data Link Bandwidth[1:0]: These two READ/WRITE bit-fields are used to select the Data Link Bandwidth (for the transmission of Data Link Messages) within the outbound DS1 data-stream. Data Link Messages can be transmitted at a rate of either 4kHz or 2kHz. The Relationship between Transmit Data Link Bandwidth[1:0] and the resulting Bits/Bandwidth available for the transport of Data Link Messages within the outbound DS1 data-stream TRANSMIT DATA LINK BANDWIDTH[1:0] RESULTING BANDWIDTH AVAILABLE TO TRANSPORT DATA LINK MESSAGES WITHIN OUTBOUND DS1 DATA-STREAM 00 Data Link Bandwidth = 4kHzData Link Messages are being transported via every single DL bit-field within the outbound DS1 data-stream 01 Data Link Bandwidth = 2kHz (Frames 1, 5, 9, ….)Data Link Messages are being transported via every other DL bit-field within the outbound DS1 data-stream. 268 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS The Relationship between Transmit Data Link Bandwidth[1:0] and the resulting Bits/Bandwidth available for the transport of Data Link Messages within the outbound DS1 data-stream TRANSMIT DATA LINK BANDWIDTH[1:0] RESULTING BANDWIDTH AVAILABLE TO TRANSPORT DATA LINK MESSAGES WITHIN OUTBOUND DS1 DATA-STREAM 10 Data Link Bandwidth = 2kHz (Frames 3, 7, 11,…)Data Link Messages are being transported via every other DL bit-field within the outbound DS1 data-stream. 11 Do not use NOTE: This bit-field only applies if the channel has been configured to operate in the T1-ESF Framing format. BIT [3:2] - Transmit D/E Time Source Select[1:0]: These two READ/WRITE bit-fields are used to specify the source of the data that is to be transported via the D/E time-slots within the outbound Transmit DS1 Data-stream. The Relationship between Transmit D/E Time Source Select[1:0] and the resulting source of the D/ETime-Slot data within the outbound DS1 data-stream TRANSMIT D/E TIME SOURCE SELECT[1:0] SOURCE FOR TRANSMIT D/E TIME-SLOT DATA 00 Upstream Circuitry (for Aggregation Applications) or the TxDS1DATA_n input (for 28-Channel DS1 Framer/LIU Combo Mode applications). 01 The Transmit LAPD Controller Block 10 Reserved - Do NOT Use 11 NOTE: These two register bits are only active if the user has configured one of the Time-Slots (within the outbound DS1 data-stream) to function as the D/E Channel. BIT [1:0] - Transmit Data Link Source Select[1:0]: These two READ/WRITE bit-fields are used to specify the source for the data that will be transported via the Data Link bits, within the outbound DS1 data-stream. The Relationship between Transmit Data Link Source Select[1:0] and the Resulting source of the data (which is to be transported via the Data Link bits, within the outbound DS1 data-stream) TRANSMIT DATA LINK SOURCE SELECT[1:0] RESULTING SOURCE OF DATA LINK DATA 00 Transmit LAPD Controller Block (within the Transmit DS1 Framer block) 01 Upstream Circuitry (for Aggregation Applications) or the TxDS1DATA_n input (for 28-Channel DS1 Framer/LIU Combo Mode Applications) 10 Reserved 11 Data Link Bits are each Forced to 1. 269 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 401: T1 FRAMER BLOCK - FRAMING CONTROL REGISTER (ADDRESS = 0XN10B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Reframe Framing with CRC Checking R/W R/W R/W R/W R/W R/W R/W R/W 0 1 0 0 0 0 0 0 LOF Tolerance[2:0] BIT 1 BIT 0 LOF Range[2:0] BIT7 - Reframe: This READ/WRITE bit-field is used to command a Reframe to the Receive DS1 Framer block. A 0 to 1 transition (within this bit-field) will force the Receive DS1 Framer block to restart the frame synchronization process. The Receive DS1 Framer block will automatically clear this bit-field to 0 once it has reacquired frame synchronization with the incoming DS1 data-stream. BIT6 - Framing with CRC Checking: This READ/WRITE bit-field is used to configure the Receive DS1 Framer block to also include checking for correct CRC6 values as a part of In-Frame Declaration criteria. More specifically, if the user enables this feature, then the Receive DS1 Framer block will also check and verify that the incoming DS1 data-stream contains correct CRC data, prior to declaring the In-Frame condition. ` 0 = CRC Verification is NOT included in the Framing Alignment process. ` 1 = The Receive DS1 Framer block will also check for correct CRC values prior to declaring the In-Frame condition. BIT [5:3] - LOF Tolerance[2:0]: NOTE: These READ/WRITE bit-fields along with the LOF Range[2:0] bit-fields are used to define the LOF Defect Declaration criteria. The Receive DS1 Framer block will declare the LOF defect condition anytime it detects LOF_Tolerance[2:0](or more) framing bit errors, within any sliding window (consisting of LOF_Range[2:0] framing The recommended value for LOF_Tolerance[2:0] is 2. BIT [2:0] - LOF Range[2:0]: These READ/WRITE bit-fields along with the LOF_Tolerance[2:0] bit-fields are used to define the LOF Defect Declaration criteria. The Receive DS1 Framer block will declare the LOF defect condition anytime it detects LOF_Tolerance[2:0] (or more) framing bit errors, within any sliding window (consisting of LOF_Range[2:0] framing alignments) within the incoming DS1 data-stream. TABLE 402: T1 FRAMER BLOCK - RECEIVE SIGNALING & DATA LINK SELECT REGISTER (ADDRESS = 0XN10C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 Reserved BIT 5 BIT 4 Receive Data Link Bandwidth[1:0] BIT 3 BIT 2 Receive D/E Time-Slot Destination Select[1:0] BIT 1 BIT 0 Receive Data-Link Destination Select[1:0] R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Reserved: BIT [5:4] - Received Data Link Bandwidth[1:0]: These two READ/WRITE bit-fields is used to select the Data Link Bandwidth (for the reception of Data Link Messages) within the incoming DS1 data-stream. Data Link Messages can be received at a rate of either 4kHz or 2kHz. 270 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS The Relationship between Receive Data Link Bandwidth[1:0] and the resulting Bits/Bandwidth available for the transport of Data Link Messages within the incoming DS1 data-stream RESULTING BANDWIDTH AVAILABLE TO TRANSPORT DATA LINK MESSAGES WITHIN INCOMING DS1 DATA-STREAM RECEIVE DATA LINK BANDIDTH[1:0] 00 Data Link Bandwidth = 4kHzData Link Messages are being transported via every single DL bit-field within the incoming DS1 data-stream 01 Data Link Bandwidth = 2kHz (Frames 1, 5, 9, ….)Data Link Messages are being transported via every other DL bit-field within the incoming DS1 datastream. 10 Data Link Bandwidth = 2kHz (Frames 3, 7, 11,…)Data Link Messages are being transported via every other DL bit-field within the incoming DS1 datastream. 11 Do not use NOTE: This bit-field only applies if the channel has been configured to operate in the T1-ESF Framing format. BIT [3:2] - Receive D/E Time-Slot Destination Select[1:0]: These two READ/WRITE bit-fields are used to specify the source of the data that is to be transported via the D/E timeslots within the incoming Receive DS1 Data-stream. The Relationship between Receive D/E Time Source Select[1:0] and the resulting source of the D/ETime-Slot data within the incoming DS1 data-stream RECEIVE D/E TIME SOURCE SELECT[1:0] DESTINATION OF THE INCOMING RECEIVE D/E TIME-SLOT DATA 00 Downstream Circuitry (for Aggregation Applications) or the RxDS1DATA_n output (for 28-Channel DS1 Framer/LIU Combo Mode applications). 01 The Receive LAPD Controller Block 10 Reserved - Do NOT Use 11 NOTE: These two register bits are only active if the user has configured one of the Time-Slots (within the incoming DS1 data-stream) to function as the D/E Channel. BIT [1:0] - Receive Data Link Destination Select[1:0]: These two READ/WRITE bit-fields are used to specify the source for the data that will be transported via the Data Link bits, within the incoming DS1 data-stream. The Relationship between Receive Data Link Source Select[1:0] and the Resulting source of the data (which is to be transported via the Data Link bits, within the incoming DS1 data-stream) TRANSMIT DATA LINK SOURCE SELECT[1:0] RESULTING DESTINATION OF DATA LINK DATA 00 Receive LAPD Controller Block (within the Receive DS1 Framer block) 01 Downstream Circuitry (for Aggregation Applications) or the RxDS1DATA_n output (for 28-Channel DS1 Framer/LIU Combo Mode Applications) 10 Reserved 11 Data Link Bits are ignored 271 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 403: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 0 (ADDRESS = 0XN10D, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Signaling Change Channel 0 Receive Signaling Change Channel 1 Receive Signaling Change Channel 2 Receive Signaling Change Channel 3 Receive Signaling Change Channel 4 Receive Signaling Change Channel 5 Receive Signaling Change Channel 6 Receive Signaling Change Channel 7 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Signaling Change - Channel n=[0:7]: These RESET-upon-READ bit-fields indicate whether the Channel Associated Signaling data associated with TimeSlots 0 through 7 (within the incoming DS1 data-stream) has changed since the last read of this register. ` 0 = Indicates that CAS data (for Time-Slots 0 through 7) has NOT changed since the last read of this register. ` 1 = Indicates that CAS data (for Time-Slots 0 through 7) has changed since the last read of this register. NOTE: This register is only active if the incoming DS1 data-stream is using Channel Associated Signaling. TABLE 404: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 1 (ADDRESS = 0XN10E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Signaling Change Channel 8 Receive Signaling Change Channel 9 Receive Signaling Change Channel 10 Receive Signaling Change Channel 11 Receive Signaling Change Channel 12 Receive Signaling Change Channel 13 Receive Signaling Change Channel 14 Receive Signaling Change Channel 15 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Signaling Change - Channel n=[8:15]: These RESET-upon-READ bit-fields indicate whether the Channel Associated Signaling data associated with TimeSlots 8 through 15 (within the incoming DS1 data-stream) has changed since the last read of this register. ` 0 = Indicates that CAS data (for Time-Slots 8 through 15) has NOT changed since the last read of this register. ` 1 = Indicates that CAS data (for Time-Slots 8 through 15) has changed since the last read of this register. TABLE 405: T1 FRAMER BLOCK - RECEIVE SIGNALING CHANGE REGISTER - 2 (ADDRESS = 0XN10F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Signaling Change Channel 16 Receive Signaling Change Channel 17 Receive Signaling Change Channel 18 Receive Signaling Change Channel 19 Receive Signaling Change Channel 20 Receive Signaling Change Channel 21 Receive Signaling Change Channel 22 Receive Signaling Change Channel 23 RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - Receive Signaling Change - Channel n=[16:23]: These RESET-upon-READ bit-fields indicate whether the Channel Associated Signaling data associated with TimeSlots 16 through 23 (within the incoming DS1 data-stream) has changed since the last read of this register. 272 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 0 = Indicates that CAS data (for Time-Slots 16 through 23) has NOT changed since the last read of this register. ` 1 = Indicates that CAS data (for Time-Slots 16 through 23) has changed since the last read of this register. NOTE: This register is only active if the incoming DS1 data-stream is using Channel Associated Signaling. TABLE 406: T1 FRAMER BLOCK - RECEIVE EXTRA-BITS REGISTER (ADDRESS = 0XN112, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 In Frame State BIT 2 BIT 1 BIT 0 Reserved R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT7 - In Frame State: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently declaring the In-Frame condition within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block is currently declaring the LOF (Loss of Frame) defect condition. ` 1 = Indicates that the Receive DS1 Framer block is currently declaring itself to be in the In-Frame condition. BIT [6:0] - Reserved TABLE 407: T1 FRAMER BLOCK - DATA LINK CONTROL REGISTER (ADDRESS = 0XN113, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Reserved MOS Abort Disable Rx_FCS_DI S AutoRx Tx_ABORT Tx_IDLE Tx_FCS_EN MOS/BOS R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reserved BIT6 - MOS Abort Disable: This bit is used to either enable or disable the automatic MOS abort feature within the transmit HDLC controller. If the user enables this feature, then the transmit HDLC controller will automatically transmit the abort sequence (e.g., a zero followed by a string of 7 consecutive 1's) whenever it abruptly transitions from transmitting a MOS type of message to transmitting a BOS type of message. ` 0 = Enables the Automatic MOS Abort feature ` 1 = Disabled BIT 5 - Receive Frame Check Sequence Disable: This bit is used to configure the receive HDLC controller to compute and verify the FCS value within each incoming LAPD message frame. ` 0 = Enables FCS Verification ` 1 = Disabled BIT 4 - Auto Receive: This bit configures the receive HDLC controller to discard any incoming BOS or LAPD message frame that exactly match which is currently stored in the receive HDLC buffer. ` 0 = Disabled ` 1 = Enables this auto discard feature BIT 3 - Transmit Abort: This bit configures the transmit HDLC controller to transmit an abort sequence (string of 7 or more consecutive 1's) to 273 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 the remote terminal. ` 0 = Disabled ` 1 = Transmit the abort sequence BIT 2 - Transmit Idle (Flag Sequence Byte): This bit configures the transmit HDLC controller to unconditionally transmit a repeating string of flag sequence octets (0x7E) in the data link channel to the remote terminal. In normal conditions, the transmit HDLC controller will repeatedly transmit the flag sequence octet whenever there is no MOS message to transmit to the remote terminal equipment. However, if the user invokes this transmit idle sequence feature, then the transmit HDLC controller will UNCONDITIONALLY transmit a repeating stream of the flag sequence octet (thereby overwriting all outbound MOS data link messages). ` 0 = Disabled ` 1 = Transmit a repeating string of Flag Sequence Octets (0x7E) NOTE: This bit is ignored if the transmit HDLC controller is operating in the BOS mode (bit 0 within this register is set to 0). BIT 1 - Transmit Frame Check Sequence Enable: This bit is used to configure the transmit HDLC controller to compute and append FCS octets to the back end of each outbound MOS data link message. ` 0 = Disabled ` 1 = Compute and append the FCS octets to the back end of each outbound MOS data link message NOTE: This bit is ignored if the transmit HDLC controller ahs been configured to operate in the BOS mode - BIT 0 within this register is set to 0). BIT 0 - MOS / BOS: This bit is used to configure transmit and receive the HDLC to be transmitting and receiving either BOS (bit oriented signaling) or MOS (message oriented signaling) frames. ` 0 = Transmit and Receive BOS Messages ` 1 = Transmit and Receive MOS Messages TABLE 408: T1 FRAMER BLOCK - TRANSMIT DATA LINK CONTROL REGISTER (ADDRESS = 0XN114, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 TxHDLC BUFAVAIL BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit HDLC Message Byte Count R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Transmit HDLC Buffer Available: This bit has different functions depending upon whether the user is writing to or reading from this register. If User is Writing Data Into This Register Bit ` 0 = Configures the transmit HDLC controller to read out and transmit the data, residing within the transmit HDLC buffer 0 via the data link channel to the remote terminal equipment. ` 1 = Configures the transmit HDLC controller to read out and transmit the data, residing within the transmit HDLC buffer 1 via the data link channel to the remote terminal equipment. If User is Reading Data From This Register Bit ` 0 = Indicates that transmit buffer 0 is the next available buffer. In this case, to write in the contents of a new outbound data link message into the transmit HDLC message buffer, the message should be written into buffer 0. ` 1 = Indicates that transmit buffer 1 is the next available buffer. In this case, to write in the contents of a new outbound data link message into the transmit HDLC message buffer, the message should be written into buffer 1. 274 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: If one of these transmit HDLC buffers contain a message which has yet to be completely read in and processed for transmission by the transmit HDLC controller, then this bit will automatically reflect the value corresponding to the next available buffer when it is read. Changing this bit to the in use buffer is not permitted. BIT [6:0] - Transmit HDLC Message Byte Count: The exact function of these bits depends on whether the transmit HDLC controller is configured to transmit MOS or BOS messages to the remote terminal equipment. In BOS Mode: These bit fields contain the number of repetitions the BOS message must be transmitted before the transmit HDLC controller generates the transmit end of transfer (TxEOT) interrupt and halts transmission. If these fields are set to 0000000, then the BOS message will be transmitted for an indefinite number of times. In MOS Mode: These bit fields contain the length, in number of octets, of the message to be transmitted. The length of MOS message specified in these bits include header bytes such as the SAPI, TEI, and Control Field. However, it does not include the FCS bytes. TABLE 409: T1 FRAMER BLOCK - RECEIVE DATA LINK CONTROL REGISTER (ADDRESS = 0XN115, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 RBUFPTR BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive HDLC Message Byte Count R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Receive HDLC Buffer Pointer: This bit identifies which receive HDLC buffer contains the most recently received HDLC message. ` 0 = Indicates that receive HDLC buffer 0 contains the contents of the most recently received HDLC message. ` 1 = Indicates that receive HDLC buffer 1 contains the contents of the most recently received HDLC message. BIT [6:0] - Receive HDLC Message Byte Count: The exact function of these bits depends on whether the receive HDLC controller is configured to receive MOS or BOS messages. In BOS Mode: These seven bits contain the number of repetitions the BOS message must be received before the receive HDLC controller generates the receive end of transfer (RxEOT) interrupt. If these bits are set to 0000000, the message will be received indefinitely and no RxEOT interrupt will be generated. In MOS Mode: These seven bits contain the size in bytes of the HDLC message that has been received and written into the receive HDLC buffer. The length of MOS message shown in these bits include header bytes such as the SAPI, TEI, Control Field, and the FCS bytes. TABLE 410: T1 FRAMER BLOCK - CUSTOMER INSTALLATION ALARM GENERATION REGISTERS (ADDRESS = 0XN11C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 Unused BIT 3 BIT 2 Customer Installation Alarm Generation[1:0] BIT 1 BIT 0 Customer Installation Alarm Detection[1:0] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [3:2] - CI Alarm Transmit (Only in ESF) These two bits are used to enable or disable AIS-CI or RAI-CI generation in T1 ESF mode only. AIS-CI and RAI-CI are 275 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 intended for use in a network to differentiate between an issue within the network or the Customer Installation (CI). AIS-CI AIS-CI is an all ones with an embedded signature of 01111100 11111111 (right-to-left) which recurs at 386 bit intervals in the DS-1 signal. RAI-CI Remote Alarm Indication (RAI-CI) is a repetitive pattern with a period of 1.08 seconds. It comprises 0.99 seconds of RAI message (00000000 11111111 right-to-left) and a 90 ms of RAI-CI signature (00111110 11111111 right-to-left) to form an RAI-CI signal. ` 00/11 = Disabled ` 01 = Enables unframed AIS-CI alarm generation ` 10 = Enables RAI-CI alarm generation BIT [1:0] - CI Alarm Detect (Only in ESF) These two bits are used to enable or disable AIS-CI or RAI-CI alarm detection in T1 ESF only. ` 00/11 = Disabled ` 01 = Enables unframed AIS-CI alarm detection ` 10 = Enables RAI-CI alarm detection TABLE 411: T1 FRAMER BLOCK - DS1 TEST REGISTER - 2 (ADDRESS = 0XN121, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 Reset by Register BIT 5 BIT 4 BIT 3 Unused PRBS Switch BIT 2 BIT 1 BER Control[1:0] BIT 0 Unframed PRBS R/W R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - Reset by Register: This READ/WRITE bit-field is used to execute a Software RESET to the T1/E1 Framer block, within a given channel. ` 0 = Configures the T1/E1 Framer block to operate normally. ` 1 = Configures the T1/E1 Framer block (of the corresponding channel) to operate in the Software RESET condition. NOTE: Once the T1/E1 Framer block exits the Software RESET state, it will automatically clear this bit-field to 0. BIT [6:4] - Reserved These bits are reserved BIT 3 - PRBS Switch: This READ/WRITE bit-field is used to specify the direction that the PRBS Pattern will be transmitted. ` 0 = PRBS Pattern will be generated and transmitted towards Transmit Output of the Transmit DS1 Framer block. This PRBS Pattern will also be monitored at the Receive Input of the corresponding Receive DS1 Framer block. ` 1 = PRBS Pattern will be generated and transmitted towards the System Side Output of the Receive DS1 Framer block. This PRBS Pattern will also be monitored at the System-Side Input of the Transmit DS1 Framer block. BIT [2:1] BER Control[1:0]: These READ/WRITE bit-fields is used to configure the PRBS Generator (within the Transmit DS1 Framer block) to insert BIT-Errors. Resulting Errors Generated by the PRBS Generator BER CONTROL[1:0] 00 RESULTING ERRORS GENERATED BY THE PRBS GENERATOR No Bit Error Inserted 276 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Resulting Errors Generated by the PRBS Generator BER CONTROL[1:0] RESULTING ERRORS GENERATED BY THE PRBS GENERATOR 01 1 Erred bit per 1,000 bits is inserted 10 1 Erred bit per 1,000,000 bits is inserted 11 No Bit Error Inserted BIT 0 - Unframed PRBS: This READ/WRITE bit-field is used to configure the Transmit DS1 Framer block to generate and transmit either a framed or unframed PRBS Pattern. Likewise, this bit-field also configures the corresponding Receive DS1 Framer block to expect either a framed or unframed PRBS pattern. ` 0 = Transmit and Receive DS1 Framer block will handle framed PRBS Pattern. ` 1 = Transmit and Receive DS1 Framer block will handle unframed PRBS Pattern. TABLE 412: T1 FRAMER BLOCK - DS1 TEST REGISTER - 1 (ADDRESS = 0XN123, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 PRBS Type Error Insert Data Invert Receive PRBS Lock Receive PRBS Enable Transmit PRBS Enable Receive DS1 By Pass Transmit DS1 By Pass R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT7 - PRBS Type: This READ/WRITE bit-field is used to specify the type of random pattern that the PRBS Generator and PRBS Receiver will handle. ` 0 = A PRBS Pattern with the Polynomial of X^15 + X^14 + 1. ` 1 = A QRTS Pattern BIT6 - Error Insert: This READ/WRITE bit-field is used to configure the PRBS Generator to insert a single bit-error into the outbound PRBS data-stream. ` A 0 to 1 transition, within this bit-field causes the PRBS Generator to insert a single bit-error into the outbound PRBS data-stream. BIT 5 - Data Invert: This READ/WRITE bit-field is used to (1) configure the PRBS Generator to invert all of its outbound traffic (as it generates and transmits this data), and (2) configures the PRBS Receiver to invert all of the incoming PRBS pattern data prior to processing. ` 0 = No Inversion by either the PRBS Generator or the PRBS Receiver ` 1 = Configures Inversion by both the PRBS Generator and PRBS Receiver BIT 4 - Receive PRBS Lock: This READ-ONLY bit-field indicates whether or not the PRBS Receiver is currently declaring PRBS Lock with the incoming PRBS data-stream. ` 0 = PRBS Receiver is NOT currently declaring PRBS Lock. ` 1 = PRBS Receiver is CURRENTLY declaring PRBS Lock. BIT 3 - Receive PRBS Detection/Generation Enable: This READ/WRITE bit-field is used to either enable or disable the PRBS Receiver. ` 0 = Disables the PRBS Receiver 277 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 ` 1 = Enables the PRBS Receiver BIT 2 - Transmit PRBS Generation Enable: This READ/WRITE bit-field is used to either enable or disable the PRBS Generator. ` 0 = Disables the PRBS Generator ` 1 = Enables the PRBS Generator BIT 1 - Receive DS1 By-Pass: This bits enables the receive T1 Framer Bypass Mode ` 0 = Disabled ` 1 = Enables Receive Framer Bypass BIT 0 - Transmit DS1 By-Pass: This bits enables the transmit T1 Framer Bypass Mode ` 0 = Disabled ` 1 = Enables Transmit Framer Bypass TABLE 413: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 0(ADDRESS = 0XN124, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 Receive Loop-Back Code Activation Length[1:0] BIT 5 BIT 4 BIT 3 Receive Loop-Back Code Deactivation Length[1:0] BIT 2 Transmit Loop-back Code Length[1:0] BIT 1 BIT 0 Framed Loop-Back Code Loop-Back Automatically R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Receive Loop-Back Code Activation Length[1:0]: These two READ/WRITE bit-fields are used to specify the length of the loop-back activation code that the Receive DS1 Framer block will will use (for Code 0). Receive Loop-Back Code Activation Length RECEIVE LOOP-BACK CODE ACTIVATION LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 10 6 Bit Sequence 11 7 Bit Sequence BIT [5:4] - Receive Loop-Back Code Deactivation Length[1:0]: These two READ/WRITE bit-fields are used to specify the length of the loop-back deactivation code that the Receive DS1 Framer block will use (for Code 0). Receive Loop-Back Code De-activation Length RECEIVE LOOP-BACK CODE DE-ACTIVATION LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 278 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Receive Loop-Back Code De-activation Length RECEIVE LOOP-BACK CODE DE-ACTIVATION LENGTH[1:0] LENGTH 10 6 Bit Sequence 11 7 Bit Sequence BIT [3:2] - Transmit Loop-Back Code Length[1:0]: These two READ/WRITE bit-fields are used to specify the length of the loop-back codes that the Transmit DS1 Framer block will transmit to the remote terminal equipment anytime the user commands it to transmit the User-Specified Loopcode to the remote terminal equipment.. Transmit Loop-Back Code Length TRANSMIT LOOP-BACK CODE LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 10 6 Bit Sequence 11 7 Bit Sequence BIT 1 - Framed Loop-Back Code: This READ/WRITE bit-field is used to configure the Transmit DS1 Framer and Receive DS1 Framer blocks to transmit and detect either framed or un-framed loop-codes (for Code 0).. ` 0 = Configures the Transmit DS1 Framer block to transmit loop-codes within an unframed DS1 data-stream, and configures the Receive DS1 Framer block to detect loop-codes within an unframed DS1 data-stream. ` 1 = Configures the Transmit DS1 Framer block to transmit loop-codes within a framed DS1 data-stream, and configures the Receive DS1 Framer block to detect loop-codes within a framed DS1 data-stream. BIT 0 - Loop-Back Automatically: This READ/WRITE bit-field is used to configure the Channel to operate in the Auto Loop-back Mode. If the user configures the Channel to operate in the Auto Loop-back Mode, then all of the following is TRUE. • The DS1 Framer block will automatically enter the Remote Loop-back Mode anytime the Receive DS1 Framer block detects and validates the Loop-up code within the incoming DS1 data-stream. • The DS1 Framer block will automatically exit the Remote Loop-back Mode anytime the Receive DS1 Framer block detects and validates the Loop-Down code within the incoming DS1 data-stream. ` 0 = Does not configure the Channel to operate in the Auto Loop-Back Mode. ` 1 = Configures the Channel to operate in the Auto Loop-Back Mode TABLE 414: T1 FRAMER BLOCK - TRANSMIT LOOP-BACK CODE REGISTER (ADDRESS = 0XN125, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Transmit Loop-back Code[6:0] BIT 0 Transmit Loop-back Code Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 279 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT [7:1] - Transmit Loop-back Code[6:0]: These READ/WRITE bit-fields is used to specify the loop-back code that the Transmit DS1 Framer block will transmit (to the remote terminal equipment) whenever the user commands it to do so by setting BIT 0 (Transmit Loop-Back Code Enable) to 1, within this register. BIT 0 - Transmit Loop-back Code Enable: This READ/WRITE bit-field is used to command the Transmit DS1 Framer block to transmit the Loop-back Code (which has been written into Bits 7 through 1, within this register) to the remote terminal. ` 0 = Configures the Transmit DS1 Framer block to NOT transmit the Loop-back Code to the remote terminal equipment. ` 1 = Configures the Transmit DS1 Framer block to transmit the Loop-back code to the remote terminal equipment. NOTE: The Transmit DS1 Framer block will repeatedly transmit the loop-back code for the duration that this bit-field is set to 1. TABLE 415: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 0 (ADDRESS = 0XN126, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Receive Loop-Back Activation Code[6:0] BIT 0 Receive Activation LoopBack Code Detect Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 BIT [7:1] - Receive Loop-Back Activation Code[6:0]: These seven (7) READ/WRITE bit-fields are used to specify/define one of the threee possible loop-code patterns that the Receive DS1 Framer block should respond to, and interpret as being the Loop-Up (or Loop-Back Activate) code. NOTES: 1. These READ/WRITE bit-fields are only active if BIT 0 (Receive Activation Loop-Back Code Detect Enable) has been set to 1. 2. The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 0". BIT 0 - Receive Activation Loop-Back Code Detect Enable: This READ/WRITE bit-field is used to either enable or disable the Receive DS1 Framer block for Loop-Back Activation Code detection for Code 0. If the user enables the Receive DS1 Framer block for Loop-Back Activation Code detection for Code 0, then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will also begin to check the incoming DS1 data-stream for the presence of the Loop-Back Activation Code (which has been defined in Bits 7 through 1 within this particular register). ` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the Loop-Back Activation code. ` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the LoopBack Activation code. 280 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 416: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 0 (ADDRESS = 0XN127, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Receive Loop-Back Deactivation Code[6:0] BIT 0 Receive Deactivation Loop-Back Code Detect Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 BIT [7:1] - Receive Loop-Back Deactivation Code[6:0]: These seven (7) READ/WRITE bit-fields are used to specify/define one of the three possible loop-code pattern that the Receive DS1 Framer block should respond to, and interpret as being the Loop-Down (or Loop-Back Deactivate) code. NOTES: 1. These READ/WRITE bit-fields are only active if BIT 0 (Receive Deactivation Loop-Back Code Detect Enable) has been set to 1. 2. The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as Code 0, Code 1"and Code 2 within this document. This particular register applies to "ode 0. BIT 0 - Receive Deactivation Loop-Back Code Detect Enable: This READ/WRITE bit-field is used to either enable or disable the Receive DS1 Framer block for Loop-Back Deactivation Code detection for Code 0. If the user enables the Receive DS1 Framer block for Loop-Back Deactivation Code detection for Code 0, then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will also begin to check the incoming DS1 data-stream for the presence of the Loop-Back Deactivation Code (which has been defined in Bits 7 through 1 within this particular register). ` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the Loop-Back Deactivation code. ` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the LoopBack Deactivation code. page 695 of word TABLE 417: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 1 (ADDRESS = 0XN12A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 Receive Loop-Back Code Activation Length[1:0] BIT 5 BIT 4 BIT 3 Receive Loop-Back Code Deactivation Length[1:0] BIT 2 Unused BIT 1 BIT 0 Framed Loop-Back Code Unused R/W R/W R/W R/W R/O R/O R/W R/O 0 0 0 0 0 0 0 0 Bits [7:6] - Receive Loop-Back Code Activation Length[1:0]: These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back activation" code that the Receive DS1 Framer block will use (for Code 1), as depicted below in Table _. 281 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 RECEIVE LOOP-BACK CODE ACTIVATION LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 10 6 Bit Sequence 11 7 Bit Sequence Bits [5:4] - Receive Loop-Back Code Deactivation Length[1:0]: These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back deactivation" code that the Receive DS1 Framer block will use (for Code 1), as depicted below in Table _. RECEIVE LOOP-BACK CODE DE-ACTIVATION LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 10 6 Bit Sequence 11 7 Bit Sequence Bits [3:2] - Reserved: Bit 1 - Framed Loop-Back Code: This READ/WRITE bit-field permits the user to configure the Transmit DS1 Framer and Receive DS1 Framer blocks to transmit and detect either "framed" or "un-framed" loop-codes (for Code 1), as depicted below. ` 0 = Configures the Transmit DS1 Framer block to transmit loop-codes within an "unframed" DS1 data-stream, and configures the Receive DS1 Framer block to detect loop-codes within an "unframed" DS1 data-stream. ` 1 = Configures the Transmit DS1 Framer block to transmit loop-codes within a "framed" DS1 data-stream, and configures the Receive DS1 Framer block to detect loop-codes within a "framed" DS1 data-stream. Bit 0 - Reserved: TABLE 418: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 1 (ADDRESS = 0XN12B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Receive Loop-Back Activation Code[6:0] BIT 0 Receive Activation Loop-Back Code Detect Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 Bits [7:1] - Receive Loop-Back Activation Code[6:0]: These seven (7) READ/WRITE bit-fields are used to specify/define one of the three possible "loop-code" patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Up" (or Loop-Back Activate) code. NOTES: 282 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTES: 1. These READ/WRITE bit-fields are only active if Bit 0 (Receive Activation Loop-Back Code Detect Enable) has been set to "1". 2. The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 1". Bit 0 - Receive Activation Loop-Back Code Detect Enable: This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back Activation" Code detection for "Code 1". If the user enables the Receive DS1 Framer block for "Loop-Back Activation" Code detection (for Code 1), then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Activation" Code (which has been defined in Bits 7 through 1 within this particular register). ` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the "Loop-Back Activation" code. ` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Activation" code. TABLE 419: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 1 (ADDRESS = 0XN12C, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Receive Loop-Back Deactivation Code[6:0] BIT 0 Receive Deactivation Loop-Back Code Detect Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 Bits [7:1] - Receive Loop-Back Deactivation Code[6:0]: These seven (7) READ/WRITE bit-fields permits the user to specify/define one of the three possible "loop-code" patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Down" (or Loop-Back Deactivate) code. NOTES: 1. These READ/WRITE bit-fields are only active if Bit 0 (Receive Deactivation Loop-Back Code Detect Enable) has been set to "1". 2. The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 1". Bit 0 - Receive Deactivation Loop-Back Code Detect Enable: This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back Deactivation" Code detection for "Code 1". If the user enables the Receive DS1 Framer block for "Loop-Back Deactivation" Code detection (for Code 1), then the Receive DS1 Framer block (as it is receiving its incoming DS1 datastream) will also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Deactivation" Code (which has been defined in Bits 7 through 1 within this particular register). ` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the "Loop-Back Deactivation" code. ` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Deactivation" code. 283 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 420: T1 FRAMER BLOCK - LOOP-BACK CODE CONTROL REGISTER - CODE 2 (ADDRESS = 0XN12D, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 Receive Loop-Back Code Activation Length[1:0] BIT 4 BIT 3 Receive Loop-Back Code Deactivation Length[1:0] BIT 2 Unused BIT 1 BIT 0 Framed Loop-Back Code Unused R/W R/W R/W R/W R/O R/O R/W R/O 0 0 0 0 0 0 0 0 Bits [7:6] - Receive Loop-Back Code Activation Length[1:0]: These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back activation" code that the Receive DS1 Framer block will use (for Code 2), as depicted below in Table _. RECEIVE LOOP-BACK CODE ACTIVATION LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 10 6 Bit Sequence 11 7 Bit Sequence Bits [5:4] - Receive Loop-Back Code Deactivation Length[1:0]: These two READ/WRITE bit-fields permit the user to specify the length of the "loop-back deactivation" code that the Receive DS1 Framer block will use (for Code 2), as depicted below in Table _. RECEIVE LOOP-BACK CODE DE-ACTIVATION LENGTH[1:0] LENGTH 00 4 Bit Sequence 01 5 Bit Sequence 10 6 Bit Sequence 11 7 Bit Sequence Bits [3:2] - Reserved: Bit 1 - Framed Loop-Back Code: This READ/WRITE bit-field permits the user to configure the Transmit DS1 Framer and Receive DS1 Framer blocks to transmit and detect either "framed" or "un-framed" loop-codes (for Code 2), as depicted below. ` 0 = Configures the Transmit DS1 Framer block to transmit loop-codes within an "unframed" DS1 data-stream, and configures the Receive DS1 Framer block to detect loop-codes within an "unframed" DS1 data-stream. ` 1 = Configures the Transmit DS1 Framer block to transmit loop-codes within a "framed" DS1 data-stream, and configures the Receive DS1 Framer block to detect loop-codes within a "framed" DS1 data-stream. Bit 0 - Reserved: 284 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 421: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK ACTIVATION CODE REGISTER - CODE 2 (ADDRESS = 0XN12E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Receive Loop-Back Activation Code[6:0] Receive Activation Loop-Back Code Detect Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 Bits [7:1] - Receive Loop-Back Activation Code[6:0]: These seven (7) READ/WRITE bit-fields permits the user to specify/define one of the three possible "loop-code" patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Up" (or Loop-Back Activate) code. NOTES: 1. These READ/WRITE bit-fields are only active if Bit 0 (Receive Activation Loop-Back Code Detect Enable) has been set to "1". 2. The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 2". Bit 0 - Receive Activation Loop-Back Code Detect Enable: This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back Activation" Code detection for "Code 2". If the user enables the Receive DS1 Framer block for "Loop-Back Activation" Code detection (for Code 2), then the Receive DS1 Framer block (as it is receiving its incoming DS1 data-stream) will also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Activation" Code (which has been defined in Bits 7 through 1 within this particular register). ` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the "Loop-Back Activation" code. ` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Activation" code. TABLE 422: RECEIVE T1 FRAMER BLOCK - RECEIVE LOOP-BACK DEACTIVATION CODE REGISTER - CODE 2 (ADDRESS = 0XN12F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Receive Loop-Back Deactivation Code[6:0] BIT 0 Receive Deactivation Loop-Back Code Detect Enable R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 Bits [7:1] - Receive Loop-Back Deactivation Code[6:0]: These seven (7) READ/WRITE bit-fields permits the user to specify/define one of the three possible "loop-code" patterns that the Receive DS1 Framer block should respond to, and interpret as being the "Loop-Down" (or Loop-Back Deactivate) code. NOTES: 1. These READ/WRITE bit-fields are only active if Bit 0 (Receive Deactivation Loop-Back Code Detect Enable) has been set to "1". 285 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 2. The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 2". Bit 0 - Receive Deactivation Loop-Back Code Detect Enable: This READ/WRITE bit-field permits the user to either enable or disable the Receive DS1 Framer block for "Loop-Back Deactivation" Code detection for "Code 2". If the user enables the Receive DS1 Framer block for "Loop-Back Deactivation" Code detection (for Code 2), then the Receive DS1 Framer block (as it is receiving its incoming DS1 datastream) will also begin to check the incoming DS1 data-stream for the presence of the "Loop-Back Deactivation" Code (which has been defined in Bits 7 through 1 within this particular register). ` 0 = Configures the Receive DS1 Framer block to NOT check the incoming DS1 data-stream for the presence of the "Loop-Back Deactivation" code. ` 1 = Configures the Receive DS1 Framer block to check the incoming DS1 data-stream for the presence of the "LoopBack Deactivation" code. TABLE 423: T1 FRAMER BLOCK - TRANSMIT CHANNEL CONTROL REGISTER - T1 TIME SLOT # 0 (ADDRESS = 0XN300, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 Reserved BIT 5 BIT 4 BIT 3 Transmit Zero Suppression[1:0] BIT 2 BIT 1 BIT 0 Transmit Channel Conditioning[3:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - Reserved. BIT [5:4] - Transmit Zero Suppression[1:0]: BIT [3:0] - Transmit Channel Conditioning[3:0]: These READ/WRITE bit-fields are used to specify how Time-Slot # 0 (within the Transmit DS1 signal is conditioned or modified). Transmit Channel Conditioning TRANSMIT CHANNEL CONDITIONING[3:0] RESULTING CONDITIONING OF TIME-SLOT # 0 0000 The Input PCM data is unchanged (Normal Operation) 0001 All 8-bits of the PCM data are inverted 0010 The even bits of the PCM data are inverted 0011 The odd bits of the PCM data are inverted 0100 PCM Data is replaced with User Code Data 0101 PCM Data is replaced with the BUSY Code (0x7F) 0110 PCM Data is replaced with the VACANT Code (0xFF) 0111 PCM Data is replaced with the BUSY Time-Slot Pattern (0xE0 in the case of Time-Slot # 0). 1000 PCM Data is replaced with the MUX Out of Frame (MOOF) Pattern (0x1A). 286 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 424: T1 FRAMER BLOCK - LAPD BUFFER 0 CONTROL REGISTER (ADDRESS = 0XN600 - 0XN640, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LAPD Buffer 0 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] LAPD Buffer 0: This register is used to transmit and receive LAPD messages within buffer 0 of the HDLC controller. Users should determine the next available buffer by reading the BUFAVAL bit (BIT7 of the Transmit Data Link Byte Count Register 0xN114h). If buffer 0 is available, writing to buffer 0 will insert the message into the outgoing LAPD frame after the LAPD message is sent and the data from the transmit buffer cannot be retrieved. After detecting the receive end of transfer interrupt (RxEOT), users should read the RBUFPTR bit (bit 7 of the receive data link byte count register 0xN115h) to determine which buffer contains the received LAPD message ready to be read. If RBUFPTR bit indicates that buffer 0 is available to be read, reading buffer 0 continuously will retrieve the entire received LAPD message. NOTE: When writing to or reading from Buffer 0, the register is automatically incremented such that the entire 64 Byte LAPD message can be written into or read from buffer 0 continuously. TABLE 425: T1 FRAMER BLOCK - LAPD BUFFER 1 CONTROL REGISTER (ADDRESS = 0XN700 - 0XN740, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 LAPD Buffer 1 R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT [7:0] LAPD Buffer 1: This register is used to transmit and receive LAPD messages within buffer 1 of the HDLC controller. Users should determine the next available buffer by reading the BUFAVAL bit (BIT7 of the Transmit Data Link Byte Count Register 0xN114h). If buffer 1 is available, writing to buffer 1 will insert the message into the outgoing LAPD frame after the LAPD message is sent and the data from the transmit buffer cannot be retrieved. After detecting the receive end of transfer interrupt (RxEOT), users should read the RBUFPTR bit (bit 7 of the receive data link byte count register 0xN115h) to determine which buffer contains the received LAPD message ready to be read. If RBUFPTR bit indicates that buffer 1 is available to be read, reading buffer 1 continuously will retrieve the entire received LAPD message. NOTE: When writing to or reading from Buffer 1, the register is automatically incremented such that the entire 64 Byte LAPD message can be written into or read from buffer 1 continuously. 287 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 426: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER CODE 0 (ADDRESS = 0XNB0A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 AUXP Pattern State Change of AUXP State Interrupt Status CRC-4 to Non CRC-4 Inter-networking Status Change of CRC-4 to Non-CRC-4 Inter-networking Status Receive Loop-Back Activation Status -Code 0 Receive Loop-Back Deactivation Status -Code 0 Change of Receive Loop-Back Activation State Interrupt Status -Code 0 Change of Receive Loop-Back Deactivation State I nterrupt Status -Code 0 R/O RUR R/O RUR R/O R/O RUR RUR 0 0 0 0 0 0 0 0 BIT7 - AUXP Pattern State: This READ-ONLY register bit indicates whether or not the Receive DS1 Framer block is currently detecting the AUXP pattern within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting the AUXP pattern within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting the AUXP pattern within the incoming DS1 data-stream. BIT6 - Change of AUXP State Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has declared the Change of AUXP State Interrupt since the last read of this register. The Receive DS1 Framer block will generate the Change of AUXP State Interrupt in response to either of the following conditions. • Whenever it begins to detect the AUXP Pattern within the incoming DS1 data-stream, and • Whenever it ceases to detect the AUXP Pattern within the incoming DS1 data-stream. ` 0 = Indicates that the Change of AUXP Status Interrupt has NOT occurred since the last read of this register. ` 1 = Indicates that the Change of AUXP Status Interrupt has occurred since the last read of this register.r BIT 5 - CRC-4 to Non-CRC-4 Internetworking Status: BIT 4 - Change of CRC-4 to Non-CRC-4 Internetworking Status: BIT 3 - Receive Loop-Back Activation Status -Code 0: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Up (or Loop-Back Activate) code (associated with "Code 0") within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the Loop-Back Activate Code (associated with "Code 0") within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Back Activate Code (associated with "Code 0") within the incoming DS1 data-stream. NOTE: The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 0". BIT 2 - Receive Loop-Back Deactivation Status - Code 0: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Down (or Loop-Back Deactivate) code (associated with Code 0) within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the Loop-Back Deactivate Code (associated with "Code 0") within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Back Deactivate Code (associated with "Code 0") within the incoming DS1 data-stream. BIT 1 - Change of Receive Loop-Back Activation State Interrupt Status - mCode 0: 288 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the Change of Receive Loop-Back Activation State Interrupt, since the last read of this register. The Receive DS1 Framer block will generate the Change of Receive Loop-Back Activation State Interrupt in response to either of the following events. • Whenever the Receive DS1 Framer block detects (and validates) the Loop-Back Activate Code (associated with Code 0) within the incoming DS1 data-stream • Whenever the Receive DS1 Framer block ceases to detect the Loop-Back Activate code (associated with Code 0) within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block has NOT generated the Change of Receive Loop-Back Activation State Interrupt for Code 0 since the last read of this register. ` 1 = Indicates that the Receive DS1 Framer block has generated the Change of Receive Loop-Back Activation State Interrupt for Code 0 since the last read of this register. BIT 0 - Change of Receive Loop-Back Deactivation Status Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the Change of Receive Loop-Back Deactivation State Interrupt (based upon loop-code Code 0), since the last read of this register. The Receive DS1 Framer block will generate the Change of Receive Loop-Back Deactivation State Interrupt in response to either of the following events. • Whenever the Receive DS1 Framer block detects (and validates) the Loop-Back Deactivate Code (associated with Code 0) within the incoming DS1 data-stream • Whenever the Receive DS1 Framer block ceases to detect the Loop-Back Deactivate code (associated with Code 0) within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block has NOT generated the Change of Receive Loop-Back Deactivation State Interrupt for Code 0 since the last read of this register. ` 1 = Indicates that the Receive DS1 Framer block has generated the Change of Receive Loop-Back Deactivation State Interrupt for Code 0 since the last read of this register. TABLE 427: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 0 (ADDRESS = 0XNB0B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Reserved Change of AUXP State Interrupt Enable Reserved Change of CRC-4 to Non-CRC-4 Inter-Networking State Interrupt Enable R/O R/W R/O R/W R/O 0 0 0 0 0 BIT 2 BIT 1 BIT 0 Change of Receive Loop-Back Activation Interrupt Enable Code 0 Change of Receive Loop-Back Deactivation Interrupt Enable Code 0 R/O R/W R/W 0 0 0 Reserved BIT7 - Reserved: BIT6 - Change of AUXP State Interrupt Enable: This READ/WRITE bit-field is used to either enable or disable the Change of AUXP State Interrupt. If the user enables the Change of AUXP State Interrupt, then the Receive DS1 Framer block will generate the Change of AUXP State Interrupt in response to the following events. • Whenever it begins to detect the AUXP Pattern within the incoming DS1 data-stream, and • Whenever it ceases to detect the AUXP Pattern within the incoming DS1 data-stream. ` 0 = Disables the Change of AUXP State Interrupt. ` 1 = Enables the Change of AUXP State Interrupt BIT 5 - Reserved BIT 4 - Change of CRC-4 to Non-CRC-4 Internetworking Status Interrupt Enable: 289 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT [3:2] - Reserved BIT 1 - Change of Receive Loop-Back Activation Interrupt Enable - Code 0: This READ/WRITE bit-field is used to either enable or disable the Change of Receive Loop-Back Activation State Interrupt, associated with Code 0. If the user enables the Change of Receive Loop-Back Activation State Interrupt, then the Receive DS1 Framer block will generate the Change of Receive Loop-Back Activation State Interrupt in response to the following events. • Whenever it detects and validates the Receive Loop-Back Activation Pattern (associated with Code 0) within the incoming DS1 data-stream, and • Whenever it ceases to detect the Receive Loop-Back Activation Pattern (associated with Code 0) within the incoming DS1 data-stream. ` 0 = Disables the Change of Receive Loop-Back Activation State Interrupt for loop-code Code 0. ` 1 = Enables the Change of Receive Loop-Back Activation State Interrupt for loop-code Code 0 BIT 0 - Change of Receive Loop-Back Deactivation Interrupt Enable -Code 0: This READ/WRITE bit-field is used to either enable or disable the Change of Receive Loop-Back Deactivation State Interrupt associated with Code 0. If the user enables the Change of Receive Loop-Back Deactivation State Interrupt, then the Receive DS1 Framer block will generate the Change of Receive Loop-Back Deactivation State Interrupt in response to the following events. • Whenever it detects and validates the Receive Loop-Back Deactivation Pattern (associated with Code 0) within the incoming DS1 data-stream, and • Whenever it ceases to detect the Receive Loop-Back Deactivation Pattern (associated with Code 0) within the incoming DS1 data-stream. ` 0 = Disables the Change of Receive Loop-Back Deactivation State Interrupt for Code 0. ` 1 = Enables the Change of Receive Loop-Back Deactivation State Interrupt for Code 0 page 710 of word TABLE 428: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER CODE 1 (ADDRESS = 0XNB14, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Receive Loop-Back Activation Status Code 1 Receive Loop-Back Deactivation Status Code 1 Change of Receive Loop-Back Activation State Interrupt Status Code 1 Change of Receive Loop-Back Deactivation State Interrupt Status Code 1 R/O R/O R/O R/O R/O R/O RUR RUR 0 0 0 0 0 0 0 0 Bits 7 through 4 - Unused: Bit 3 - Receive Loop-Back Activation Status - Code 1: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Up (or Loop-Back Activate) code (associated with Code 1) within the incoming DS1 data-stream, as depicted below. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Activate" Code (associated with "Code 1") within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Activate" Code (associated with "Code 1") within the incoming DS1 data-stream. NOTE: The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 1". 290 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Bit 2 - Receive Loop-Back Deactivation Status - Code 1: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Down (or Loop-Back Deactivate) code (associated with Code 1) within the incoming DS1 data-stream, as depicted below. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Deactivate" Code (associated with "Code 1") within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Deactivate" Code (associated with "Code 1") within the incoming DS1 data-stream. Bit 1 - Change of Receive Loop-Back Activation State Interrupt Status - Code 1: This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Activation State" Interrupt (based upon loop-code "Code 1"), since the last read of this register. The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State" Interrupt in response to either of the following events. • Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Activate" Code (associated with "Code 1") within the incoming DS1 data-stream • Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Activate" code (associated with "Code 1") within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Activation State" Interrupt for "Code 1" since the last read of this register. ` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Activation State" Interrupt for "Code 1" since the last read of this register. Bit 0 - Change of Receive Loop-Back Deactivation Status Interrupt Status - Code 1: This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Deactivation State" Interrupt (based upon loop-code "Code 1"), since the last read of this register. The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in response to either of the following events. • Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Deactivate" Code (associated with "Code 1") within the incoming DS1 data-stream • Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Deactivate" code (associated with "Code 1") within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 1" since the last read of this register. ` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 1" since the last read of this register. TABLE 429: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 1 (ADDRESS = 0XNB15, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 Change of Receive Loop-Back Activation Interrupt Enable Code 1 Change of Receive Loop-Back Deactivation Interrupt Enable Code 1 R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 Bits 7 through 2 - Reserved: Bit 1 - Change of Receive Loop-Back Activation Interrupt Enable - Code 1: This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Activation 291 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 State" Interrupt associated with Loop-Code "Code 1". If the user enables the "Change of Receive Loop-Back Activation State" Interrupt, then the Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State" Interrupt in response to the following events. • Whenever it detects and validates the "Receive Loop-Back Activation" Pattern (associated with "Code 1") within the incoming DS1 data-stream, and • Whenever it ceases to detect the "Receive Loop-Back Activation" Pattern (associated with "Code 1") within the incoming DS1 data-stream. ` 0 = Disables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 1". ` 1 = Enables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 1". Bit 0 - Change of Receive Loop-Back Deactivation Interrupt Enable - Code 1: This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Deactivation State" Interrupt. If the user enables the "Change of Receive Loop-Back Deactivation State" Interrupt, then the Receive DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in response to the following events. • Whenever it detects and validates the "Receive Loop-Back Deactivation" Pattern (associated with "Code 1") within the incoming DS1 data-stream, and • Whenever it ceases to detect the "Receive Loop-Back Deactivation" Pattern (associated with "Code 1") within the incoming DS1 data-stream. ` 0 = Disables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 1". ` 1 = Enables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 1". TABLE 430: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT AND STATUS REGISTER CODE 2 (ADDRESS = 0XNB1A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Receive Loop-Back Activation Status Code 2 Receive Loop-Back Deactivation Status Code 2 Change of Receive Loop-Back Activation State Interrupt Status Code 2 Change of Receive Loop-Back Deactivation State Interrupt Status Code 2 R/O R/O R/O R/O R/O R/O RUR RUR 0 0 0 0 0 0 0 0 Bits 7 through 4 - Unused: Bit 3 - Receive Loop-Back Activation Status - Code 2: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Up (or Loop-Back Activate) code (associated with Code 2) within the incoming DS1 data-stream, as depicted below. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Activate" Code (associated with "Code 2") within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Activate" Code (associated with "Code 2") within the incoming DS1 data-stream. NOTE: The Receive DS1/E1 Framer block can be configured to detect three different loop activate/deactivate codes in parallel. These three (3) codes will be referred to as "Code 0", "Code 1" and "Code 2" within this document. This particular register applies to "Code 2". Bit 2 - Receive Loop-Back Deactivation Status - Code 2: This READ-ONLY bit-field indicates whether or not the Receive DS1 Framer block is currently detecting (and flagging) the Loop-Down (or Loop-Back Deactivate) code (associated with Code 2) within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block is NOT currently detecting (nor flagging) the "Loop-Back Deactivate" 292 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Code (associated with "Code 2") within the incoming DS1 data-stream. ` 1 = Indicates that the Receive DS1 Framer block is currently detecting (and flagging) the "Loop-Back Deactivate" Code (associated with "Code 2") within the incoming DS1 data-stream. Bit 1 - Change of Receive Loop-Back Activation State Interrupt Status - Code 2: This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Activation State" Interrupt (based upon loop-code "Code 2"), since the last read of this register. The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State" Interrupt in response to either of the following events. • Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Activate" Code (associated with "Code 2") within the incoming DS1 data-stream • Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Activate" code (associated with "Code 2") within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Activation State" Interrupt for "Code 2" since the last read of this register. ` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Activation State" Interrupt for "Code 2" since the last read of this register. Bit 0 - Change of Receive Loop-Back Deactivation Status Interrupt Status - Code 2: This RESET-upon-READ bit-field indicates whether or not the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Deactivation State" Interrupt (based upon loop-code "Code 2"), since the last read of this register. The Receive DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in response to either of the following events. • Whenever the Receive DS1 Framer block detects (and validates) the "Loop-Back Deactivate" Code (associated with "Code 2") within the incoming DS1 data-stream • Whenever the Receive DS1 Framer block ceases to detect the "Loop-Back Deactivate" code (associated with "Code 2") within the incoming DS1 data-stream. ` 0 = Indicates that the Receive DS1 Framer block has NOT generated the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 2" since the last read of this register. ` 1 = Indicates that the Receive DS1 Framer block has generated the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 2" since the last read of this register. TABLE 431: T1 FRAMER INTERRUPT REGISTER - RECEIVE LOOP-BACK CODE INTERRUPT ENABLE REGISTER - CODE 2 (ADDRESS = 0XNB1B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Reserved BIT 1 BIT 0 Change of Receive Loop-Back Activation Interrupt Enable Code 2 Change of Receive Loop-Back Deactivation Interrupt Enable Code 2 R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 Bits 7 through 2 - Reserved: Bit 1 - Change of Receive Loop-Back Activation Interrupt Enable - Code 2: This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Activation State" Interrupt associated with Loop-Code "Code 2". If the user enables the "Change of Receive Loop-Back Activation State" Interrupt, then the Receive DS1 Framer block will generate the "Change of Receive Loop-Back Activation State" Interrupt in response to the following events. • Whenever it detects and validates the "Receive Loop-Back Activation" Pattern (associated with "Code 2") within the incoming DS1 data-stream, and 293 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 • Whenever it ceases to detect the "Receive Loop-Back Activation" Pattern (associated with "Code 2") within the incoming DS1 data-stream. ` 0 = Disables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 2". ` 1 = Enables the "Change of Receive Loop-Back Activation State" Interrupt for loop-code "Code 2". Bit 0 - Change of Receive Loop-Back Deactivation Interrupt Enable - Code 2: This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive Loop-Back Deactivation State" Interrupt. If the user enables the "Change of Receive Loop-Back Deactivation State" Interrupt, then the Receive DS1 Framer block will generate the "Change of Receive Loop-Back Deactivation State" Interrupt in response to the following events. • Whenever it detects and validates the "Receive Loop-Back Deactivation" Pattern (associated with "Code 2") within the incoming DS1 data-stream, and • Whenever it ceases to detect the "Receive Loop-Back Deactivation" Pattern (associated with "Code 2") within the incoming DS1 data-stream. ` 0 = Disables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 2". ` 1 = Enables the "Change of Receive Loop-Back Deactivation State" Interrupt for "Code 2". 2.14 DS1/E1 FRAMER BLOCK REGISTERS - E1 APPLICATIONS TABLE 432: E1 FRAMER BLOCK - CLOCK SELECT REGISTER (ADDRESS = 0XN100, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Unused Set E1 Mode Force all Channels to Sync to 8kHz R/O R/W R/W R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 1 Unused BIT 1 BIT 0 Clock Source Select[1:0] BIT7 - Reserved BIT6 - Set T1 Mode: This READ/WRITE bit-field is used to configure the Channel to operate in either the T1 or E1 Mode. ` 0 = Configures the Framer Channel to operate in the E1 Mode ` 1 = Configures the Framer Channel to operate in the T1 Mode BIT 5 - Force all Channels to Sync to 8kHz: This READ/WRITE bit-field is used to configure all active (either 21 or 42) Transmit E1 Framer blocks to synchronize their transmit output frame alignment with the 8kHz signal that is derived from the MCLK PLL. ` 0 = Does not configure each of the Transmit E1 Framer blocks to synchronize their transmit output frame alignment with the 8kHz signal (from the MCLK PLL). ` 1 = Configures each of the Transmit E1 Framer blocks to synchronize their transmit output frame alignment with the 8kHz signal (from the MCLK PLL). NOTE: This feature should only be used if the XRT86SH328 has been configured to operate in the 21-Channel E1 Framer/LIU Combo Mode. The user MUST NOT use this feature if the XRT86SH328 has been configured to operate in any of the Aggregation Modes. BIT [4:2] - Reserved BIT [1:0] - Clock Source Select[1:0]: These two READ/WRITE bit-fields is used to specify the timing source for the Ingress and Direction Transmit E1 Framer block, within this particular channel. 294 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS The Relationship between the Clock Source Select[1:0] bit-fields and the resulting timing source for the Transmit E1 Framer block, within this particular Channel CLOCK SOURCE SELECT[1:0] 00 TIMING SOURCE FOR TRANSMIT E1 FRAMER BLOCK Loop-Timing Mode:The Transmit E1 Framer block will derive its timing from the Received or Recovered Clock signal within the corresponding Receive E1 Framer block NOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 21-Channel E1 Framer/LIU Combo Mode 01 Local-Timing Mode (TxE1CLK_n Input)The Transmit E1 Framer block will either use upstream timing or the TxE1CLK_n input as its timing source. NOTE: For Aggregation Applications, the user MUST configure all active T1/E1 Framer blocks to operate in this timing mode. 10 Local-Timing Mode (MCLK PLL Input)The Transmit E1 Framer block will derive its timing from the MCLK PLL.NOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 21-Channel E1 Framer/LIU Combo Mode. 11 Loop-Timing ModeThe Transmit E1 Framer block will derive its timing from the Received or Recovered Clock signal within the corresponding Receive E1 Framer block NOTE: This timing option is only available if the user has configured the XRT86SH328 to operate in the 21-Channel E1 Framer/LIU Combo Mode. TABLE 433: E1 FRAMER BLOCK - LINE INTERFACE CONTROL REGISTER (ADDRESS = 0XN101, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 Transmit LOS Pattern Reserved R/W R/O 0 1 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Framer LoopBack[1:0] Reserved R/W R/W R/O R/O R/O R/O 0 0 0 0 0 0 BIT7 - Transmit LOS Pattern: This READ/WRITE bit-field configures the Transmit E1 Framer block to generate and transmit the LOS Pattern to the remote terminal. ` 0 = Configures the Transmit E1 Framer Block to transmit normal E1 traffic ` 1 = Configures the Transmit E1 Framer Block to transmit the LOS pattern. NOTE: The user MUST set this bit-field to 0 for Normal Operation. BIT6 - Reserved BIT [5:4] - Framer Loop-back[1:0]: These two READ/WRITE bit-fields are used to configure the Transmit/Receive E1 Framer blocks to operate in a variety of possible loop-back modes, as depicted in the Table below. Relationship between the Framer Loop-back[1:0] bit-fields and the Corresponding Loop-Back Mode within the E1 Framer block FRAMER LOOP-BACK[1:0] RESULTING LOOP-BACK MODE (WITHIN FRAMER BLOCK) 00 Normal Operation (No Loop-back) Mode 01 Local Loop-back Mode 295 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Relationship between the Framer Loop-back[1:0] bit-fields and the Corresponding Loop-Back Mode within the E1 Framer block FRAMER LOOP-BACK[1:0] RESULTING LOOP-BACK MODE (WITHIN FRAMER BLOCK) 10 Remote Loop-back Mode 11 Reserved TABLE 434: E1 FRAMER BLOCK - FRAMING SELECT REGISTER (ADDRESS = 0XN107, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Annex B Tx CRC-4 Error R/W R/W R/W R/W R/W 0 0 0 0 0 CAS MultiFrame Sel[1:0] BIT 2 BIT 1 BIT 0 Add Frame ChkEnable FAS Frame Alignment R/W R/W R/W 0 0 0 CRC MultiFrame Sel[1:0] BIT7 - G.706 Annex B CRC-4 Calculation Enable: This bit configures the E1 receive framer block to be compliant with ITU-T G.706 Annex B for CRC-to-non-CRC interworking detection. If Annex B is enabled, G.706 Annex B CRC-4 multi frame alignment algorithm is implemented. If CRC-4 alignment is enabled and not achieved in 400 msec while the basic frame alignment signal is present, it is assumed that the remote end is a non CRC-4 equipment. A CRC-to-non-CRC interworking interrupt will be generated. ` 0 = Configures the receive E1 framer block to NOT support the G.706 Annex B CRC-4 multi frame alignment algorithm. ` 1 = Configures the receive E1 framer block to support the G.706 Annex B CRC-4 multi frame alignment algorithm. BIT6 - Transmit CRC-4 Error: This bit is used to force a continuous errored CRC pattern in the outbound CRC multi frame to be sent on the transmission line. The transmit E1 framer block will implement this error by inverting the value of CRC bit (C1). ` 0 = Disabled ` 1 = Forces the transmit E1 framer block to transmit continuous errored CRC bit. BIT [5:4] - CAS Multi Frame Select[1:0]: These bits allow the user to select which CAS multi frame alignment declaration algorithm the receive E1 framer block will employ, according to the table below. E1 Framer Block - Framing Select Register (Address = 0xN107, where N ranges in value from 0x01 to 0x38) CAS MF ALIGN SEL[1:0] 00, 11 CAS MULTI FRAME ALIGNMENT DECLARATION ALGORITHM SELECTED CAS multi frame alignment disabled. 01 The 16-Frame AlgorithmIf this alignment algorithm is selected, then the receive E1 framer block will monitor the 16th timeslot of each incoming E1 frame and will declare CAS multi frame alignment (e.g., clear the loss of CAS multi frame defect) condition anytime that it detects 15 consecutive E1 frames in which bits 1-4 (of time slot 16) do not contain the CAS Multi Frame Alignment pattern, which is immediately followed by an E1 frame that DOES contain the CAS Multi Frame Alignment pattern. 10 The 2-Frame (ITU-T G.732) AlgorithmIf this alignment algorithm is selected, then the receive E1 framer block will declare CAS multi frame alignment anytime it detects a single E1 frame rather than 15 consecutive E1 frames as described above in the 16-Frame Algorithm. 296 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: For information on the criteria that the receive E1 framer block uses in order to declare the Loss of CAS Multi Frame defect condition, please see the register description for the Framing Control Register 0xN10Bh. BIT [3:2] - CRC Multi Frame Alignment Declaration Criteria Select[1:0]: These bits allow the user to select which CRC Multi Frame Alignment declaration criteria the receive E1 framer block will employ. The receive E1 framer block will check for CRC Multi Frame Alignmnet by checking the incoming E1 data stream and determining whether the international bits (bit 1 of time slot 0) of non-FAS frames match the CRC multi frame alignment pattern (0,0,1,0,1,1,E1,E2). CAS MF Align Sel CAS MF ALIGN SEL[1:0] CAS MULTI FRAME ALIGNMENT DECLARATION ALGORITHM CRITERIA 00 CRC Multi Frame Alignment Disabled. 01 CRC Multi Frame Alignment is enabled. Alignment is declared if at least 1 valid CRC multi frame alignment signal is observed within 8 msec. 10 CRC Multi Frame Alignment is enabled. Alignment is declared if at least 2 valid CRC multi frame alignment signals are observed within 8 msec. 11 CRC Multi Frame Alignment is enabled. Alignment is declared if at least 3 valid CRC multi frame alignment signals are observed within 8 msec. NOTE: For information on the criteria that the receive E1 framer block uses to declare the Loss of CRC Multi Frame Alignment defect condition, please see the register description for the Framing Control Register 0xN10Bh. BIT 1 - Additional Frame Check Enable - FAS Frame Alignment Declaration: This bit is used to configure the receive E1 framer block to perform some additional FAS frame synchronization checking prior to declaration FAS frame alignment. If the user implements this feature, then the receive E1 framer block will perform some more testing on two additional E1 frames, prior to declaring the FAS frame Alignment condition. ` 0 = Disabled. ` 1 = Enables additional FAS frame checking. BIT 0 - FAS Alignment Declaration Algorithm Select: This bit specifies which algorithm the receive E1 framer block uses in its search for the FAS alignment. ` 0 = FAS Alignment Algorithm 1 ` 1 = FAS Alignment Algorithm 2 FAS Alignment Algorithm 1 Desciption a. Step 1: The receive E1 Framer block begins by searching for the correct 7-bit FAS pattern. Go to step 2 if found. b. Step 2: Check if the FAS is absent in the following frame by verifying that bit 2 of the assumed time slot 0 of the Non-FAS frame is a one. Go back to step 1 if failed, otherwise go to step 3. c. Step 3: check if the FAS is present in the assumed time slot 0 of the third frame. Go back to step 1 if failed. After the first three steps (if all passed), the receive E1 framer block will declare FAS in Sync if Frame Check Sequence (BIT 1 of this register) is disabled. If frame check sequence is enabled, then the receive E1 framer block will need to verify the correct frame alignment. FAS Alignment Algorithm 2 Description Algorithm 2 is similar to algorithm 1 but adds a one-frame hold off time after the second step fails. After the second step fails, it waits for the next assumed FAS in the next frame before it begins the new search for the correct FAS pattern. 297 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 435: E1 FRAMER BLOCK - ALARM GENERATION REGISTER (ADDRESS = 0XN108, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 BIT 4 BIT 3 TransmitAUXP Pattern LOF DeclarationCriteria R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Transmit YEL and Multi YEL[1:0] BIT 2 Transmit AIS Pattern Select[1:0] BIT 1 BIT 0 AIS Defect Declaration Criteria[1:0] BIT7 - Transmit Auxiliary Pattern: This bit is used to transmit an auxiliary pattern (repeating …010101) to the transmit line interface. ` 0 = Disabled ` 1 = Enable AUXP Pattern BIT6 - Loss of Frame Declaration Criteria This bit is used to select Loss of Frame Declaration Criteria for the receive E1 framer block. ` 0 = Loss of frame is declared immediately if either CRC multi frame alignment or FAS alignment is lost. ` 1 = Loss of frame is declared immediately if FAS alignment is lost. If CRC multi frame alignment is lost for more than 8 msec, the E1 receive framer will force a frame search. BIT [5:4] - Yellow Alarm and Multi Yellow Alarm Generation [1:0]: These bits activate or deactivate the transmission of yellow and multi frame yellow alarm. The yellow alarm and multi frame yellow alarm can be forced to transmit as 1, or be inserted upon detection of loss of alignment. YEL and Multi YE YEL AND MULTI YEL[1:0] 00 / 10 YELLOW ALARM TRANSMITTED Disabled. 01 Automatic Transmission of YEL and CAS Multi YELWhenever the receive E1 framer block declares LOF or Loss CAS Multi Frame Alignment, the corresponding transmit E1 framer block will automatically transmit the Yellow Alarm indicator by setting BIT 3 of time slot 0 within the non-FAS frames to 1. 11 Force Transmission of YEL and CAS Multi YELBoth Yellow and Multi Frame Yellow Alarm are transmitted as '1' BIT [3:2] - Transmit AIS Pattern Select[1:0] These two READ/WRITE bit-fields are used to select the type of AIS Pattern that the Transmit E1 Framer block will send if enabled. The Relationship between Transmit AIS Pattern Select[1:0] and the resulting behavior of the Transmit E1 Framer block TRANSMIT AIS PATTERN SELECT[1:0] TRANSMIT E1 FRAMER BLOCK ACTION 00 Transmits Normal TrafficTransmit E1 Framer block does not transmit the AIS indicator. It will (instead) transmit normal traffic 01 Unframed All Ones PatternThe Transmit E1 Framer block will transmit an Unframed All Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [0, 1]. 298 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS The Relationship between Transmit AIS Pattern Select[1:0] and the resulting behavior of the Transmit E1 Framer block TRANSMIT AIS PATTERN SELECT[1:0] TRANSMIT E1 FRAMER BLOCK ACTION 10 The AIS-16 PatternIn this case, time slot 16 in each frame will be set to an All Ones Pattern. 11 Framed All Ones PatternThe Transmit E1 Framer block will transmit a Framed All Ones Pattern (as an AIS pattern) for the duration that these bit-fields are set to [1, 0]. BIT[1:0] - AIS Defect Declaration Criteria[1:0] These two READ/WRITE bit-fields are used to select the type of AIS Pattern that the Receive E1 Framer block will look for in order to determine whether or not it should declare or clear the AIS defect condition. The Relationship between AIS Defect Declaration Criteria[1:0] and the resulting AIS Pattern that the Receive E1 Framer block will look for in declaring/clearing the AIS defect condition AIS DEFECT DECLARATION CRITERIA[1:0] RECEIVE E1 FRAMER BLOCK - AIS DEFECT DECLARATION CRITERIA 00 AIS Defect Declaration is DisabledThe Receive E1 Framer block will NOT declare the AIS defect condition at all. 01 Unframed and Framed All Ones Pattern:The Receive E1 Framer block will declare the AIS defect condition whenever it receives either the Framed or Unframed All Ones pattern for at least 42ms. 10 AIS-16 All Ones Pattern:The Receive E1 Framer block will declare the AIS defect condition whenever it receives all ones in the 16th time slot. 11 Framed All Ones Pattern:The Receive E1 Framer block will only declare the AIS defect condition whenever it receives the Framed All Ones Pattern for at least 42ms. TABLE 436: E1 FRAMER BLOCK - SYNCHRONIZATION MUX REGISTER (ADDRESS = 0XN109, WHERE N RANGES IN VALUE FROM 0X01 TO 0X38) BIT7 BIT6 BIT 5 E-Bit SourceSelect BIT 4 BIT 3 Reserved BIT 2 Data Link SourceSelect BIT 1 BIT 0 CRC-4 Source Select Framing Alignment Pattern Select R/O R/W R/W R/W R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT [7:6] - E-Bit Source Select • These bits are used to specify the source of E-bits wihin each outbound E1 frame. E-bits E-BITS [1:0] 00 E-BIT SOURCE SELECT Internal Framer BlockThe E-bits are used to indicate whether the receive E1 framer block has detected a CRC error within the most recently received sub-multi frame. The receive E1 framer will indicate a received errored sub-multi frame by setting the binary state of the E-bits from 1 to 0 for each errored sub-multi frame. 299 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 E-bits E-BITS [1:0] E-BIT SOURCE SELECT 01 All E-bits within the outbound E1 data stream are set to 0. 10 All E-bits within the outbound E1 data stream are set to 1. 11 The E-bits are used to carry the data link information. BIT [5:4] - Reserved BIT [3:2] - Data Link Source Select These bits are used to specify the source of the data link bits that will be inserted in the outbound E1 frames. YEL and Multi YEL YEL AND MULTI YEL[1:0] YELLOW ALARM TRANSMITTED 00 / 11 The transmit serial input from the transmit payload data input block will be the source for the data link bits. 01 The Transmit HDLC Controller will generate either BOS (bit oriented signaling) or MOS (message oriented signaling) messages which will be inserted into the data link bits in the outbound E1 frames. 10 Reserved. BIT 1 - CRC-4 Source Select BIT 0 - Framing Alignment Pattern Select 2.15 CHANNEL CONTROL-VT MAPPER BLOCK REGISTERS The register map for the Channel Control VT-Mapper Block registers is presented in the Table below. Additionally, a detailed description of each of the Channel Control VT-Mapper Block registers is presented below. In order to provide some orientation for the reader, an illustration of the Functional Block Diagram for the XRT86SH328, with both the VT/TU Mapper and VT/TU De-Mapper Blocks highlighted is presented below in Figure 19. 300 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS FIGURE 19. ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 DEVICE, WITH THE VTMAPPER BLOCK HIGHLIGHTED Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block To DS1/E1 Channels 1 - 3 DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 TABLE 437: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION DS1/E1 INSERTION CONTROL REGISTER - 2 (ADDRESS = 0XND41) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Transmit RDI-V Source[1:0] R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 BIT[7:2] - Unused: BIT[1:0] - Transmit RDI-V Type[1:0]: This READ/WRITE bit-field is used to specify the source of Bits 5, 6 and 7 (within the K4 VT-POH byte), whenever the Transmit VT-Mapper Block is configured to support the transmission of the Extended RDI-V indicators. Transmit RDI-V Source TRANSMIT RDI-V SOURCE[1:0] RESULTING SOURCE OF BITS 5, 6 AND 7 OF K4 BYTE 00 Receive Status per the corresponding Receive VT-Mapper Block 01 From On-Chip Register 301 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Transmit RDI-V Source TRANSMIT RDI-V SOURCE[1:0] RESULTING SOURCE OF BITS 5, 6 AND 7 OF K4 BYTE 10 Do Not Use 11 Receive Status per the corresponding Receive VT-Mapper Block TABLE 438: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL REGISTER - 1 (ADDRESS = 0XND42, WHERE N RANGES FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 Ingress Direction DS1/E1 AIS Defect Declared Unused BIP-2 Error Insert R/O R/O R/W R/W R/W 0 0 0 0 0 BIT 2 BIT 1 BIT 0 Auto Transmit RFI-V Indicator Auto Transmit RDI-V Indicator R/W R/W R/W 0 0 0 VT Signal Label[2:0] BIT 7 - Receive (Ingress Direction) DS1/E1 AIS Defect Declared: This READ/WRITE bit-field indicates whether or not the corresponding DS1 or E1 signal (that is being handled by this Transmit VT-Mapper block) is transporting the AIS indicator. ` 0 - Indicates that the Ingress Direction DS1 or E1 signal is NOT currently transporting the AIS indicator. ` 1 - Indicates that the Ingress Direction DS1 or E1 signal is currently transporting the AIS indicator. BIT 6 - Unused BIT 5 - BIP-2 Error Insert This READ/WRITE bit-field is used to configure the corresponding VT-Mapper block to transmit VTs with erred BIP-2 bits into the "Ingress Direction VT-data-stream (towards the Transmit STS-1/STS-3 POH Processor block). If the user opts to invoke this feature, then the VT-Mapper block will automatically invert the value of the "locally-computed" BIP-2 bits (within each outbound VT), prior to transmitting this data to the Transmit STS-1/STS-3 POH Processor block. ` 0 - Configures the Transmit VT-Mapper block to NOT transmit VTs with erred BIP-2 bits to downstream circuitry (normal operation). ` 1 - Configures the Transmit VT-Mapper block to transmit VTs with erred BIP-2 bits to downstream circuitry(normal operation). NOTE: For normal operation, the user should set this bit-field to 0. BIT [4:2] - VT Label[2:0]: These three (3) READ/WRITE bit-fields are used to set the VT Label bit-fields (within each outbound V5 byte) the value of the users choice. BIT 1 - Auto Transmit RFI-V Indicator This READ/WRITE bit-field is used to select the source of the RFI-V bit-field, within the V5 byte of the outbound VT1.5/VT2 traffic. In this case, the user has the following two options. a. The user can configure the VT-Mapper block to use an on-chip register as the source of the RFI-V bit-fields (within the V5 byte). More specifically, the VT-Mapper block will read out the contents within Bit 7 (Transmit RFI-V Value) within the "VT-Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register (Address = 0xND43)" and it will load this value into RFI-V bit-field position within each outbound VT. In this case, the user will have Software Control over the state of the RFI-V bit-field, within the V5 byte of the outbound VT traffic) or b. The Transmit VT-Mapper block will set the RFI-V bit-fields to the appropriate value, based upon any defect conditions that are currently being declared by the corresponding VT-De-Mapper block. ` 0 - Configures the Transmit VT-Mapper Block to use the on-chip register as the source of the RFI-V bit-field. 302 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 1 - Configures the Transmit VT-Mapper block to set the RFI-V bit-fields to the appropriate value, based upon any defects that the corresponding Receive VT-Mapper block is currently declaring. BIT 0 - Auto Transmit RDI-V Indicator This READ/WRITE bit-field is used to select the source of the RDI-V bit-field, within the V5 byte of each outbound VT1.5/VT2 traffic. In this case, the user has the following two options. a. The user can configure the Transmit VT-Mapper block to use an on-chip register as the source of the RDI-V bit-fields (within the V5 byte). More specifically, the Transmit VT-Mapper block will read out the contents within BIT6 (Transmit RDI-V value) within the VT Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register (Address = 0xND43) and it will load this value into the RDI-V bit-field position within each outbound VT. In this case, the user will have Software Control over the state of the RDI-V bit-fields, within the outbound VT traffic) or b. The Transmit VT-Mapper block will set the RDI-V bit-fields to the appropriate value, based upon any defect conditions that are currently being declared by the corresponding VT-De-Mapper block. ` 0 - Configures the Transmit VT-Mapper Block to use the on-chip register as the source of the RDI-V bit-field. ` 1 - Configures the Transmit VT-Mapper block to set the RDI-V bit-fields to the appropriate value, based upon any defects that the corresponding VT-De-Mapper block is currently declaring. TABLE 439: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - DS1/E1 INSERTION CONTROL REGISTER - 0 (ADDRESS = 0XND43 , WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit RFI-V Value Transmit RDI-V Value Transmit AIS-V Indicator R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 DS1/E1 Cross Connect Channel Select_Ingress Direction[4:0] BIT7 - Transmit RFI-V Value: This READ/WRITE bit-field is used to exercise Software Control over the state of the RFI-V bit-field (within each V5 byte) of the outbound VT data-stream. If the user sets BIT 1 (Auto Transmit RFI-V Indicator), within the VT-Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register - 2 to 0, then the Transmit VT-Mapper block will read out the contents within this bit-field, and it will load this value into the RFI-V bit-field within each V5 byte of the outbound VTdata-stream. NOTE: This bit-field is ignored if the user sets Bit 1 (Auto Transmit RFI-V Indicator), within the VT Mapper Block Ingress Direction - DS1/E1 Insertion Control Register - 1 to 1. BIT6 - Transmit RDI-V Value: This READ/WRITE bit-field is used to exercise Software Control over the state of the RDI-V bit-field (within each V5 byte) of the outbound VT data-stream. If the user sets BIT 0 (Auto Transmit RDI-V Indicator), within the VT-Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register - 2 to 0, then the Transmit VT-Mapper block will read out the contents within this bit-field, and it will load this value into the RDI-V bit-field within each V5 byte of the outbound VT-data-stream. NOTE: This bit-field is ignored if the user sets Bit 0 (Auto Transmit RDI-V Indicator), within the VT Mapper Block Ingress Direction - DS1/E1 Insertion Control Register - 1 to 1. BIT 5 - Transmit AIS-V Indicator This READ/WRITE bit-field is used to command the Transmit VT-Mappper block to transmit the AIS-V indicator (within the corresponding VT1.5 or VT2) within the outbound VT-data-stream. 0 - Configures the Transmit VT-Mapper block to NOT transmit the AIS-V indicator within the outbound VT-data-stream. 1 - Configures the Transmit VT-Mapper block to transmit the AIS-V indicator within the outbound VT-data-stream as shown in Figure 20. 303 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 FIGURE 20. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328 WHENEVER THE VTMAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) HAS BEEN CONFIGURED TO TRANSMIT THE AIS-V INDICATOR TOWARDS DOWN-STREAM CIRCUITRY Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block AIS-V Indicator VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 BIT[4:0] - DS1/E1 (Cross-Connect) Channel Select[4:0]: These READ/WRITE bit-fields is used to configure the Internal VT-Cross Connect. More specifically, these READ/WRITE bit-fields are used to select which (of the 28 Ingress Direction) T1/E1 signals to be mapped into either a VT1.5 or VT2 by this particular Transmit VT-Mapper block. The following table presents the relationship between the settings of these bit-fields and the resulting Cross Connect Configuration. Cross Connect Configuration DS1/E1 (CROSSCONNECT) CHANNEL SELECT[4:0] RESULTING INGRESS DIRECTION T1/E1 CHANNEL BEING HANDLED BY THIS PARTICULAR TRANSMIT VT-MAPPER BLOCK 00000 NONE 00001 Ingress Direction T1/E1 Channel 1 00010 Ingress Direction T1/E1 Channel 2 00011 Ingress Direction T1/E1 Channel 3 00100 Ingress Direction T1/E1 Channel 4 00101 Ingress Direction T1/E1 Channel 5 COMMENTS This particular VT will be transmitted as an Un-equipped signal 304 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Cross Connect Configuration DS1/E1 (CROSSCONNECT) CHANNEL SELECT[4:0] RESULTING INGRESS DIRECTION T1/E1 CHANNEL BEING HANDLED BY THIS PARTICULAR TRANSMIT VT-MAPPER BLOCK 00110 Ingress Direction T1/E1 Channel 6 00111 Ingress Direction T1/E1 Channel 7 01000 Ingress Direction T1/E1 Channel 8 01001 Ingress Direction T1/E1 Channel 9 01010 Ingress Direction T1/E1 Channel 10 01011 Ingress Direction T1/E1 Channel 11 01100 Ingress Direction T1/E1 Channel 12 01101 Ingress Direction T1/E1 Channel 13 01110 Ingress Direction T1/E1 Channel 14 01111 Ingress Direction T1/E1 Channel 15 10000 Ingress Direction T1/E1 Channel 16 10001 Ingress Direction T1/E1 Channel 17 10010 Ingress Direction T1/E1 Channel 18 10011 Ingress Direction T1/E1 Channel 19 10100 Ingress Direction T1/E1 Channel 20 10101 Ingress Direction T1/E1 Channel 21 10110 Ingress Direction T1/E1 Channel 22 10111 Ingress Direction T1/E1 Channel 23 11000 Ingress Direction T1/E1 Channel 24 11001 Ingress Direction T1/E1 Channel 25 11010 Ingress Direction T1/E1 Channel 26 11011 Ingress Direction T1/E1 Channel 27 11100 Ingress Direction T1/E1 Channel 28 11101 NONE 11110 The Test Channel 11111 Test Pattern - From VT Pattern Generator 305 COMMENTS PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 440: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 3 (ADDRESS = 0XND44, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 RDI-V Accepted Value[3:0] BIT 2 BIT 1 BIT 0 RDI-V Accept Threshold[3:0] R/O R/O R/O R/O R/W R/W R/W R/W 0 0 0 0 0 0 0 0 BIT[7:4] - RDI-V Accepted Value[3:0]: These READ-ONLY bit-fields reflect the most recently value for RDI-V that has been accepted (or validated) by the VTDe--Mapper Block. The VT-De--Mapper block will accept (or validate) a given RDI-V value, once it has received this same RDI-V value, within RDI-V_Accept_Threshold[3:0] number of consecutive, incoming VT Multi-frames. NOTES: 1. These bit-fields are only active if the user has configured the Receive VT-De-Mapper block to support ERDI-V (Enhanced RDI-V). 2. These bit-fields reflect the four-bit RDI-V value that the VT De-Mapper block has accepted via the K4 bytes within the incoming VT/TU data-stream. BIT[3:0] - RDI-V Accept Threshold[3:0]: These READ/WRITE bit-fields are used to define the RDI-V Validation criteria for the VT-De-Mapper block. More specifically, these bit-fields are used to specify the number of consecutive, incoming VT Multi-frame, in which the VTDe-Mapper block MUST receive a given RDI-V value BEFORE it validates it and loads it into BIT[7:4] (RDI-V Accepted Value[3:0]). TABLE 441: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 2 (ADDRESS = 0XND45, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Unused BIT 0 RDI-V Type R/O R/O R/O R/O R/O R/O R/O R/W 0 0 0 0 0 0 0 0 BIT[7:1] - Unused: BIT 0 - RDI-V Type: This READ/WRITE bit-field is used to configure the VT-De-Mapper blocks (associated with a given channel) to support either the SRDI-V (Single Bit - RDI-V) or ERDI-V (Extended - RDI-V) form of signaling. If the user uses only Single-Bit RDI-V, then the RDI-V indicator will only be transported via Bit 8 (RDI-V) within the V5 byte in a VT-data-stream. Conversely, if a user uses Extended RDI-V, then the RDI-V indicator will be transported via both Bits 8 (RDI-V) within the V5 byte, and Bits 5, 6 and 7 within the Z7/K4 byte. ` 0 - Configures the VT-De-Mapper blocks to use the SRDI-V form of Signaling. ` 1 - Configures the VT-De-Mapper blocks to use the ERDI-V form of signaling. NOTE: This configuration setting only applies to the VT-De-Mapper block. If the user wishes to configure the VT-Mapper block to support either the "SRDI-V" or the "ERDI-V" form of signaling, then he/she must set Bit 1 (RDI-V Type) within the "Channel Control - VT-Mapper Block - Ingress Direction - Transmit RDI-V Control Register - Byte 0" to the appropriate state. 306 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 442: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYTE 1 (ADDRESS = 0XND46, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Unused VT Size Error Defect Declared LOP-V Defect Declared Change in VT Label Value[2:0] Indicator R/O R/O R/O R/W1C R/O R/O R/O R/O 0 0 1 0 0 0 0 0 VT Label Value[2:0] BIT 0 AIS-V Defect Declared BIT7 -Unused: BIT6 - VT Size ErroDefect Declared: This READ-ONLY bit-field indicates whether or not the Receive VT-De-Mapper block is currently declaring the VT Size Error defect condition. The Receive VT-De-Mapper block will declare the VT Size Error defect condition anytime it receives a VT data-stream with V1 bytes that contains the incorrect VT-Size bit values, as depicted below. ` 0 - Indicates that the Receive VT-De-Mapper block is NOT currently declaring the VT Size Error Defect condition. ` 1 - Indicates that the Receive VT-De-Mapper block is currently declaring the VT Size Error Defect condition. BIT 5 - LOP-V Defect Declared: This READ-ONLY bit-field indicates whether or not the Receive VT-Mapper block is currently declaring the LOP-V Defect condition. ` 0 - Indicates that the Receive VT-De-Mapper Block is currently NOT declaring the LOP-V Defect Condition. ` 1 - Indicates that the Receive VT-De-Mapper block is currently declaring the LOP-V Defect Condition BIT 4 - Change in VT Label[2:0] Indicator: This READ/WRITE 1 to CLEAR bit-field indicates whether or not the Receive VT-De-Mapper block has detected a Change in VT Signal Label, since the last time the user read and cleared this register bit 0 - Indicates that the Receive VT-De-Mapper block has NOT detected a Change in VT Signal Label since the last time the user read and cleared this register bit. BIT[3:1] - VT Label Value[2:0]: This READ-ONLY bit-field reflects the value of the most recently accepted (or validated) VT Signal Label value. BIT 0 - AIS-V Defect Declared: This READ-ONLY bit-field indicates whether or not the Receive VT-De- Mapper block is currently declaring the AIS-V defect condition. ` 0 - Indicates that the Receive VT-De-Mapper Block is NOT currently declaring the AIS-V defect condition. ` 1 - Indicates that the Receive VT-De-Mapper Block is currently declaring the AIS-V defect condition. TABLE 443: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - ENGRESS DIRECTION - DS1/E1 DROP CONTROL REGISTER - BYT E 0 (ADDRESS = 0XND47, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 RFI-V Defect Declared RDI-V Defect Declared Force DS1/E1 AIS In Egress Direction R/O R/O R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 DS1/E1 Cross Connect Channel Select_Egress Direction[4:0] 307 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 BIT7 - RFI-V Defect Declared: This READ/WRITE bit-field indicates whether or not the Receive VT-De-Mapper Block is currently declaring the RFI-V defect condition. ` 0 - Indicates that the Receive VT-De-Mapper Block is NOT currently declaring the RFI-V defect condition. ` 1 - Indicates that the Receive VT-De-Mapper Block is currently declaring the RFI-V defect condition. BIT6 - RDI-V Defect Declared: This READ/WRITE bit-field indicates whether or not the Receive VT-De-Mapper Block is currently declaring the RDI-V defect condition. ` 0 - Indicates that the Receive VT-De-Mapper Block is NOT currently declaring the RDI-V defect condition. ` 1 - Indicates that the Receive VT-De-Mapper Block is currently declaring the RDI-V defect condition. BIT 5 - Force DS1/E1 AIS In Egress Direction This READ/WRITE bit-field is used to configure this particular Receive VT-De-Mapper block to transmit the DS1/E1 AIS indicator within the Egress Direction of this particular DS1/E1 Channel. ` 0 - Configures the Receive VT-De-Mapper Block to NOT transmit the DS1/E1 AIS Pattern within the Egress Direction corresponding to this particular channel. ` 1 - Configures the Receive VT-De-Mapper block to transmit the DS1/E1 AIS Pattern within the Egress Direction corresponding to this particular channel. Figure 21 presents an illustration of the Functional Block Diagram of the XRT86SH328, whenever the VT-De-Mapper block has been configured to overwrite the contents within the corresponding DS1/E1 channel with the DS1/E1 AIS pattern (as it is being de-mapped from the VT1.5 or VT2 data-stream by the VT De-Mapper block. FIGURE 21. AN ILLUSTRATION OF THE FUNCTIONAL BLOCK DIAGRAM OF THE XRT86SH328, WHENEVER THE VTDE-MAPPER BLOCK (ASSOCIATED WITH A GIVEN CHANNEL) OVERWRITES THE CONTENTS OF A DE-MAPPED DS1/E1 SIGNAL WITH THE DS1/E1 AIS PATTERN STS-1/ STS-1/ STS-3 STS-3 Telecom Telecom Bus Bus Interface Interface Transmit Transmit STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Transmit Transmit STS-1 STS-1POH POH Processor Processor Block Block VT/TU VT/TU Mapper Mapper Block Block Ingress Direction Transmit DS1/E1 Framer Block Ingress Direction Receive DS1/E1 Framer Block Receive DS1/E1 LIU Block DS1/E1 Channel 0 From DS1/E1 Channels 1 - 27 From DS2 Channels 1 - 6 Transmit Transmit DS3 DS3 Framer Framer Block Block DS3/ DS3/ STS-1 STS-1 LIU LIU Interface Interface M23 M23 MUX MUX Block Block M12 MUX Block From DS1/E1 Channels 1 - 3 DS2 Channel 0 Receive Receive DS3 DS3 Framer Framer Block Block M23 M23 De-MUX De-MUX Block Block M12 De-MUX Block DS2 Channel 0 To DS1/E1 Channels 1 - 27 Receive Receive STS-1/3 STS-1/3 TOH TOH Processor Processor Block Block Receive Receive STS-1 STS-1POH POH Processor Processor Block Block To DS1/E1 Channels 1 - 3 To DS2 Channels 1 - 6 VT/TU De-Mapper Block DS1/E1 AIS 308 DS1/E1 Jitter Atten Block Egress Direction Receive DS1/E1 Framer Block Egress Direction Transmit DS1/E1 Framer Block Transmit DS1/E1 LIU Block DS1/E1 Channel 0 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS BIT[4:0] - DS1/E1 Cross Connect Channel Select_Egress Direction[4:0]: These READ/WRITE bit-fields are used to configure the Internal VT-Cross Connect. More specifically, these READ/WRITE bit-fields are used to select which (of the 28 Egress Direction) T1/E1 Ports, that this particular Receive VT-Mapper block will route (or direct) its Egress Direction T1/E1 Signal to. The following table presents the relationship between the settings of these bit-fields and the resulting Cross-Connect Configuration. Cross Connect Configuration DS1/E1 (CROSS CONNECT) CHANNEL SELECT[4:0] RESULTING PORT THAT THIS RECEIVE VT-MAPPER BLOCK WILL DIRECT ITS T1/E1 TRAFFIC TO 00000 No Clock or Data is output via Corresponding Egress Direction T1/E1 Port 00001 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 1 00010 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 2 00011 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 3 00100 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 4 00101 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 5 00110 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 6 00111 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 7 01000 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 8 01001 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 9 01010 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 10 01011 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 11 01100 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 12 01101 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 13 01110 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 14 01111 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 15 10000 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 16 309 COMMENTS PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 Cross Connect Configuration DS1/E1 (CROSS CONNECT) CHANNEL SELECT[4:0] RESULTING PORT THAT THIS RECEIVE VT-MAPPER BLOCK WILL DIRECT ITS T1/E1 TRAFFIC TO 10001 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 17 10010 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 18 10011 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 19 10100 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 20 10101 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 21 10110 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 22 10111 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 23 11000 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 24 11001 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 25 11010 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 26 11011 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 27 11100 Egress Direction T1/E1 Signal is routed to the Egress Direction Output of T1/E1 Channel 28 COMMENTS 11101 11110 11111 TABLE 444: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER BYTE 1 (ADDRESS = 0XND4A, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 VT Payload Pointer Increment Count[3:0] BIT 2 BIT 1 BIT 0 BIP-2 Error Count[11:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT 7 - 4 - VT Payload Pointer Increment Count[3:0]: These RESET-upon-READ bit-fields reflect the number of VT Payload Pointer Increment events that the Receive VTDe-Mapper block has detected since the last read of this register. The Receive VT-Mapper block will increment the contents within these bit-fields each time that it detects a VT Payload Pointer Increment event within the incoming VT data-stream. 310 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields. BIT[3:0] - BIP-2 Error Count[11:8]: These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 0, presents a 12-bit expression that reflects the number of BIP-2 Errors that the Receive VTMapper Block has detected (within the incoming VT-data-stream) since the last read of this register. These particular bit-fields are the four most significant bit-fields within this 12-bit expression. NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT DeMapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields TABLE 445: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - BIP-2 ERROR COUNT REGISTER BYTE 0 (ADDRESS = 0XND4B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 BIP-2 Error Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:0] - BIP-2 Error Count[7:0]: These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - BIP-2 Error Count Register - Byte 1, presents a 12-bit expression that reflects the number of BIP-2 Errors that the Receive VT-DeMapper Block has detected (within the incoming VT-data-stream) since the last read of this register. These particular bit-fields are the eight least significant bit-fields within this 12-bit expression. NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields. TABLE 446: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER BYTE 1 (ADDRESS = 0XND4E, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 VT-Payload Pointer Decrement Count[3:0] BIT 2 BIT 1 BIT 0 REI-V Event Count[11:8] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT [7:4] - VT Payload Pointer Decrement Count[3:0]: These RESET-upon-READ bit-fields reflect the number of VT Payload Pointer Decrement events that the Receive VTDe-Mapper block has detected since the last read of this register. The Receive VT-Mapper block will increment the contents within these bit-fields each time that it detects a VT Payload Pointer Decrement event within the incoming VT data-stream. NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields BIT [3:0] - REI-V Event Count[11:8]: These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - REI-V Event Count Register - Byte 0, presents a 12-bit expression that reflects the number of REI-V Events that the Receive VTMapper Block has detected (within the incoming VT-data-stream) since the last read of this register. These particular bit-fields are the four most significant bit-fields within this 12-bit expression. NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields. 311 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 447: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - REI-V EVENT COUNT REGISTER BYTE 0 (ADDRESS = 0XND4F, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT7 BIT6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 REI-V Event Count[7:0] RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 BIT[7:0] - REI-V Event Count[7:0]: These RESET-upon-READ bit-fields, along with those within the VT Mapper Block - Egress Direction - REI-V Event Count Register - Byte 1, presents a 12-bit expression that reflects the number of REI-V Events that the Receive VT-DeMapper Block has detected (within the incoming VT-data-stream) since the last read of this register. These particular bit-fields are the eight least significant bit-fields within this 12-bit expression. NOTE: The user must induce a "0 to 1 transition" within Bit 3 (Latch Count) within the "Global VT-Mapper Block - VT Mapper Block Control Register (Address = 0x0C03) prior to reading out the contents within these bit-fields. TABLE 448: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - RECEIVE APS REGISTER - BYTE 0 (ADDRESS = 0XND53, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 Receive APS Value[3:0] R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - 4 - Unused: This READ/WTC bit-field indicates whether or not the Change of Receive APS Value event has occurred (within this Tributary) since the last time that the user has written a 1 to clear this bit-field. The Receive VT-De-Mapper block will declare the Change of Receive APS Value whenever it has accepted a new value from the K4 bytes within the incoming VT data-stream. ` 0 - Indicates that the Change of Receive APS Value event has NOT occurred since the last time the user has written a 1 to clear this bit-field. ` 1 - Indicates that the Change of Receive APS Value event has occurred since the last time the user has written a 1 to clear this bit-field. BIT 3 - 0 - Receive APS Value[3:0]: These four (4) READ-ONLY bit-field reflects the APS value that the VT-De-Mapper block has received (via Bits 1 through 4, within the K4 byte) and has validated. TABLE 449: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS REGISTER - BYTE 2 (ADDRESS = 0XND56, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 DS1/E1 AIS DS1/E1 LOC - Event Mask -Event Mask BIT 4 Reserved BIT 3 BIT 2 Transmit Elastic Store Overflow BIT 1 BIT 0 Reserved R/W R/O R/O R/O RUR R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - Change of DS1/E1 AIS Defect Condition - Event Mask: This READ/WRITE bit-field permits the user to either enable or disable the "Change of DS1/E1 AIS Defect Condition" event to/from causing the "Change of DS1/E1 AIS Defect Condition" interrupt to be generated. If the user enables this 312 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS feature, then the VT-Mapper block will assert the "Change of DS1/E1 AIS Defect Condition" interrupt in response to either of the following conditions. • Whenever the VT-Mapper block declares the "DS1/E1 AIS" defect condition within the Ingress Direction DS1/E1 Data-stream. • Whenever the VT-Mapper block clears the "DS1/E1 AIS" defect condition within the Ingress Direction DS1/E1 Data Stream. ` 0 - Configures the VT-Mapper Block to NOT generate the "Change of DS1/E1 AIS Defect Condition" interrupt, whenever it declares or clears the DS1/E1 AIS defect condition. ` 1 - Configures the VT-Mapper Block to generate the "Change of DS1/E1 AIS Defect Condition" interrupt, whenever it declares or clears the "DS1/E1 AIS defect condition. BIT 6 - 4 Reserved: BIT 3 - Transmit Elastic Store Overflow: This RESET-upon-READ bit-field indicates whether or not the VT Mapper block has declared a "Transmit Elastic Store Overflow" event since the last read of this register. The VT-Mapper Block will declare a "Transmit Elastic Store Overflow" event anytime that the "Transmit FIFO" (within the VT-Mapper block) has experience an "overflow" event. ` 0 - Indicates that the "Transmit Elastic Store Overflow" event has NOT occurred since the last read of this register. ` 1 - Indicates that the "Transmit Elastic Store Overflow" event has occurred since the last read of this register. NOTE: The VT-Mapper block will typically handle "small timing offsets" (between the Ingress Direction T1/E1 signal and the "Transmit Direction" 19.44MHz or 51.84MHz clock signal via bit-stuffing (as it maps this T1/E1 data into VTs. However, if this bit-field is set to "1", this is typically a indication of a significant clock frequency accuracy problem within the system. BIT 0 - Reserved: TABLE 450: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT APS/K4 REGISTER (ADDRESS = 0XND57, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 TxERDI ] BIT 1 BIT 0 TxAPS[3:0 R/W R/W R/W R/W R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - Unused: BIT 6 - 4 - Transmit ERDI-V[2:0] These three (3) READ/WRITE bit-fields permit the user to exercise software control over the value of the "ERDI-V" bits that are transported via "Bits 5 through 7" (within the K4 byte) within the outbound VT data-stream. NOTE: This bit-field is only active if both of the following is true. a. The user has configured VT-Mapper/De-Mapper blocks to support the ERDI-V (Extended - RDI-V) form of signaling and, b. The user has set Bit 6 (Transmit RDI-V Value) within the "Channel Control - VT Mapper Block - Ingress Direction - DS1/E1 Insertion Control Register - 0" to "1". BIT 3 - 0 - Transmit APS Value[3:0] These four (4) READ/WRITE bit-fields permit the user to exercise software control over the value of the "APS" bits that are transported via Bits 1 through 4 (within the K4 byte) within the outbound VT data-stream 313 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 451: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - J2 BYTE STATUS REGISTER (ADDRESS = 0XND63, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 Unused BIT 2 BIT 1 BIT 0 TIM-V Defect Declared VT Path Trace Message Unstable Defect Declared Unused R/O R/O R/O R/O R/O R/O R/O R/O 0 0 0 0 0 0 0 0 BIT 7 - 3 - Unused: BIT 2 - TIM-V Defect Declared: This READ-ONLY bit-field indicates whether or not the VT-De-Mapper block is currently declaring the "VT Trace Identification Mismatch" (TIM-V) defect condition. The VT-De-Mapper block will declare the TIM-V defect condition, when none of the received 1, 16 or 64-byte string (received via the J2 byte, within the incoming VT-data-stream) matches the expected 1, 16 or 64 byte message. The VT-De-Mapper block will clear the "TIM-V" defect condition, when 80% of the received 1, 16 or 64 byte string (received via the J2 byte) matches the 1, 16 or 64 byte message. ` 0 - Indicates that the VT-De-Mapper block is NOT currently declaring the TIM-V defect condition. ` 1 - Indicates that the VT-De-Mapper block is currently declaring the TIM-V defect condition. BIT 1 - VT Path Trace Message Unstable Defect Declared: This READ-ONLY bit-field indicates whether or not the VT-De-Mapper block is currently declaring the "VT Path Trace Message Unstable" defect condition. The VT-De-Mapper block will declare the "VT Path Trace Message Unstable" defect condition, whenever the "VT Path Trace Message Unstable" counter reaches the value "8". The VT-De-Mapper block will increment the "VT Path Trace Message Unstable" counter for each time that it receives a "VT Path Trace Message" that differs from the previously received message. The "VT Path Trace Message Unstable" counter is cleared to "0" whenever the VT-De-Mapper block has received a given "VT Path Trace Message" 3 (or 5) consecutive times. ` 0 - Indicates that the VT-De-Mapper block is NOT currently declaring the "VT:Path Trace Message Unstable" defect condition. ` 1 - Indicates that the VT De-Mapper block is currently declaring the "VT Path Trace Message Unstable" defect condition. NOTE: The VT-De-Mapper block will also set this bit-field "0" anytime it receives a given "VT Path Trace Message" 3 (or 5) consecutive times. BIT 0 - Unused: TABLE 452: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER BYTE 0 (ADDRESS = 0XND64, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Change of Receive APS Value Composite Elastic Store Overflow Event Composite R/O R/O R/O R/O R/O R/O RUR RUR 0 0 0 0 0 0 0 0 Bits 7 - 2: Unused: Bit 1 - Change of Receive APS Value Interrupt: This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of 314 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Receive APS Value" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt whenever it has "accepted" a new "APS" value (from the K4 bytes within the incoming VT-data-stream). ` 0 - Indicates that the "Change of Receive APS Value" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of Receive APS Value" Interrupt has occurred since the last read of this register. Bit 0 - Transmit or Receive Elastic Store Overflow Event Interrupt: This RESET-upon-READ bit-field indicates whether or not the "VT Mapper/VT-De-Mapper" block has generated the "Elastic Store Overflow Event" Interrupt since the last read of this register. The VT-Mapper/De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the "Transmit FIFO" within the VT-Mapper Block, experiences an overflow event. • Whenever the "Receive FIFO" within the VT-De-Mapper Block, experiences an overflow event. ` 0 - Indicates that the channel has NOT generated an "Elastic Store Overflow" Interrupt since the last read of this register. ` 1 - Indicates that the channel has generated an "Elastic Store Overflow" interrupt since the last read of this register. TABLE 453: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - COMPOSITE STATUS REGISTER BYTE 0 (ADDRESS = 0XND65, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 VT Size Error Interrupt Status Change of LOP-V Defect Condition Interrupt Status Change of RFI-V Defect Condition Interrupt Status Change of RDI-V Defect Condition Interrupt Status Change of AIS-V Failure Condition Interrupt Status Change of AIS-V Defect Condition Interrupt Status Change of VT Label Interrupt Status Change of DS1/E1 AIS Defect Condition Interrupt Status RUR RUR RUR RUR RUR RUR RUR RUR 0 0 0 0 0 0 0 0 Bit 7 - VT Size Error Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "VT Size Error" Interrupt since the last read of this register. The VT-De-Mapper block will generate the "VT Size Error" Interrupt anytime it declares the "VT Size Error" defect condition. ` 0 - Indicates that the VT Size Error Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the VT Size Error Interrupt has occurred since the last read of this register. Bit 6 - Change of LOP-V Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of LOP-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the VT-De-Mapper block declares the LOP-V defect condition • Whenever the VT-De-Mapper block clears the LOP-V defect condition. ` 0 - Indicates that the "Change of LOP-V Defect Condition" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of LOP-V Defect Condition" Interrupt has occurred since the last read of this register. Bit 5 - Change of RFI-V Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of RFI-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the VT-De-Mapper block declares the RFI-V defect condition • Whenever the VT-De-Mapper block clears the RFI-V defect condition. ` 0 - Indicates that the "Change of RFI-V Defect Condition" Interrupt has NOT occurred since the last read of this 315 XRT86SH328 PRELIMINARY 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 register. ` 1 - Indicates that the "Change of RFI-V Defect Condition" Interrupt has occurred since the last read of this register. Bit 4 - Change of RDI-V Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of RDI-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the VT-De-Mapper block declares the RDI-V defect condition • Whenever the VT-De-Mapper block clears the RDI-V defect condition. ` 0 - Indicates that the "Change of RDI-V Defect Condition" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of RDI-V Defect Condition" Interrupt has occurred since the last read of this register. Bit 3 - Change of AIS-V Failure Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of AIS-V Failure Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the VT-De-Mapper block declares the AIS-V failure condition • Whenever the VT-De-Mapper block clears the AIS-V failure condition. ` 0 - Indicates that the "Change of AIS-V Failure Condition" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of AIS-V Failure Condition" Interrupt has occurred since the last read of this register. Bit 2 - Change of AIS-V Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of AIS-V Defect Condition" Interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the VT-De-Mapper block declares the AIS-V defect condition • Whenever the VT-De-Mapper block clears the AIS-V defect condition. 0 - Indicates that the "Change of AIS-V Defect Condition" Interrupt has NOT occurred since the last read of this register. 1 - Indicates that the "Change of AIS-V Defect Condition" Interrupt has occurred since the last read of this register. Bit 1 - Change of VT Label Value Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "Change of VT Label Value" Interrupt has occurred since the last read of this register. The VT-De-Mapper block will generate this interrupt anytime it has "accepted" a new VT Label value (that it has received via the V5 byte within the incoming VT data-stream). ` 0 - Indicates that the "Change of VT Label Value" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of VT Label Value" Interrupt has occurred since the last read of this register. Bit 0 - Change of DS1/E1 AIS Defect Condition Interrupt Status This RESET-upon-READ bit-field indicates whether or not the "Change of DS1/E1 AIS Defect Condition" Interrupt has occurred since the last read of this register. The VT-Mapper block will generate this interrupt in response to any one of the following conditions. • Whenever the VT-Mapper block declares the DS1/E1 AIS Defect (with the Ingress Direction T1/E1 traffic). • Whenever the VT-Mapper block clears the DS1/E1 AIS Defect (within the Ingress Direction T1/E1 traffic) ` 0 - Indicates that the "Change of DS1/E1 AIS Defect Condition" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of DS1/E1 AIS Defect Condition" Interrupt has occurred since the last read of this register. 316 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 454: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT STATUS REGISTER (ADDRESS = 0XND67, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 Change of VT Path Trace Message Unstable Defect Condition Interrupt Status New VT Path Trace Message Interrupt Status Change of TIM-V Defect Condition Interrupt Status BIT 2 BIT 1 BIT 0 Unused R/O R/O RUR RUR RUR R/O R/O R/O 0 0 0 0 0 0 0 0 Bits 7 - 6 - Unused: Bit 5 - Change of VT Path Trace Message Unstable Defect Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt has occurred since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever the VT-De-Mapper block declares the "VT Path Trace Message Unstable" Defect condition. • Whenever the VT De-Mapper block clears the "VT Path Trace Message Unstable" Defect condition. ` 0 - Indicates that the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt has occurred since the last read of this register. Bit 4 - New VT Path Trace Message Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the "New VT Path Trace Message" Interrupt has occurred since the last read of this register. The VT-De-Mapper block will generate this interrupt whenever it has "accepted" a new "VT Path Trace Message" via the incoming VT-data-stream. ` 0 - Indicates that the "New VT Path Trace Message" Interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "New VT Path Trace Message" Interrupt has occurred since the last read of this register. Bit 3 - Change of TIM-V Defect Condition Interrupt Status: This RESET-upon-READ bit-field indicates whether or not the "VT-De-Mapper" block has generated the "Change of TIM-V Defect Condition" interrupt since the last read of this register. The VT-De-Mapper block will generate this interrupt in response to either of the following conditions. • Whenever it declares the TIM-V Defect condition. • Whenever it clears the TIM-V Defect condition. ` 0 - Indicates that the "Change of TIM-V Defect Condition" interrupt has NOT occurred since the last read of this register. ` 1 - Indicates that the "Change of TIM-V Defect Condition" interrupt has occurred since the last read of this register. Bits 2 - 0 - Unused: 317 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 455: CHANNEL CONTROL - VT-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND68, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 Unused BIT 1 BIT 0 Change of Receive APS Value Interrupt Enable Elastic Store Overflow Event Interrupt Enable R/O R/O R/O R/O R/O R/O R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 2: Unused: Bit 1 - Change of Receive APS Value Interrupt Enable: This READ/WRITE bit-field permits the user to either enable or disable the "Change of Receive APS Value" Interrupt. If the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt anytime it has "accepted" a new APS value (via the K4 byte within the incoming VT-data-stream). ` 0 - Disables the "Change of Receive APS Value" Interrupt. ` 1 - Enables the "Change of Receive APS Value" Interrupt. Bit 0 - Transmit or Receive Elastic Store Overflow Event Interrupt Enable: This READ/WRITE bit-field permits the user to either enable or disable the "Elastic Store Overflow Event" interrupt. If the user enables this interrupt, then the channel will generate this interrupt in response to either of the following conditions. • Whenever the "Transmit FIFO" within the VT-Mapper Block, experiences an overflow event. • Whenever the "Receive FIFO" within the VT-De-Mapper block, experiences an overflow event. ` 0 - Disables the "Elastic Store Overflow Event" Interrupt ` 1 - Enables the "Elastic Store Overflow Event" Interrupt TABLE 456: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND69, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 VT Size Error Interrupt Enable Change of LOP-V Defect Condition I nterrupt Enable Change of RFI-V Defect Condition Interrupt Enable Change of RDI-V Defect Condition Interrupt Enable Change of AIS-V Failure Condition Interrupt Enable Change of AIS-V Defect Condition Interrupt Enable Change of VT Label Interrupt Enable Change of DS1/E1 AIS Defect Condition Interrupt Enable R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bit 7 - VT Size Error Interrupt Enable: This READ/WRITE bit-field permits the user to either enable or disable the "VT Size Error" Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt anytime it declares the "VT Size Error" defect condition. • 0 - Disables the "VT Size Error" Interrupt. • 1 - Enables the "VT Size Error" Interrupt. Bit 6 - Change of LOP-V Defect Condition Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of LOP-V Defect Condition" 318 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to either of the following conditions. • Whenever it declares the LOP-V Defect Condition • Whenever it clears the LOP-V Defect condition ` 0 - Disables the "Change of LOP-V Defect Condition" Interrupt ` 1 - Enables the "Change of LOP-V Defect Condition" Interrupt Bit 5 - Change of RFI-V Defect Condition Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of RFI-V Defect Condition" Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to either of the following conditions. • Whenever it declares the RFI-V Defect Condition • Whenever it clears the RFI-V Defect condition ` 0 - Disables the "Change of RFI-V Defect Condition" Interrupt ` 1 - Enables the "Change of RFI-V Defect Condition" Interrupt Bit 4 - Change of RDI-V Defect Condition Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of RDI-V Defect Condition" Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to either of the following conditions. • Whenever it declares the RDI-V Defect Condition • Whenever it clears the RDI-V Defect condition ` 0 - Disables the "Change of RDI-V Defect Condition" Interrupt ` 1 - Enables the "Change of RDI-V Defect Condition" Interrupt Bit 3 - Change of AIS-V Failure Condition Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of AIS-V Failure Condition" Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to either of the following conditions. • Whenever it declares the AIS-V Failure Condition • Whenever it clears the AIS-V Failure condition ` 0 - Disables the "Change of AIS-V Failure Condition" Interrupt ` 1 - Enables the "Change of AIS-V Failure Condition" Interrupt Bit 2 - Change of AIS-V Defect Condition Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of AIS-V Defect Condition" Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt in response to either of the following conditions. • Whenever it declares the AIS-V Defect Condition • Whenever it clears the AIS-V Defect condition ` 0 - Disables the "Change of AIS-V Defect Condition" Interrupt ` 1 - Enables the "Change of AIS-V Defect Condition" Interrupt Bit 1 - Change of VT Label Value Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of VT Label Value" Interrupt. If the user enables this interrupt, then the "VT-De-Mapper" block will generate this interrupt anytime it has "accepted" a new "VT Label Value" via the V5 bytes within the incoming VT-data-stream. ` 0 - Disables the "Change of VT Label Value" Interrupt. ` 1 - Enables the "Change of VT Label Value" Interrupt. Bit 0 - Change of DS1/E1 AIS Defect Condition Interrupt Enable This READ/WRITE bit-field permits the user to either enable or disable the "Change of DS1/E1 AIS Defect Condition" interrupt. If the user enables this interrupt, then the "VT-Mapper" block will generate this interrupt in response to either 319 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 of the following events. • Whenever it declares the DS1/E1 AIS defect condition. • Whenever it clears the DS1/E1 AIS defect condition ` 0 - Disables the "Change of DS1/E1 AIS Defect Condition" interrupt. ` 1 - Enables the "Change of DS1/E1 AIS Defect Condition" interrupt. TABLE 457: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - INTERRUPT ENABLE REGISTER (ADDRESS = 0XND6B, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 Change of VT Path Trace Message Unstable Defect Condition Interrupt Enable New VT Path Trace Message Interrupt Status Change of TIM-V Defect Condition Interrupt Status BIT 2 BIT 1 BIT 0 Unused R/O R/O RUR RUR RUR R/O R/O R/O 0 0 0 0 0 0 0 0 Bits 7 - 6 - Unused: Bit 5 - Change of VT Path Trace Message Unstable Defect Condition Interrupt Enable: This READ/WRITE bit-field permits the user to either enable or disable the "Change of VT Path Trace Message Unstable Defect Condition" interrupt. If the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt in response to either of the following events. • Whenever the VT-De-Mapper block declares the "VT-Path Trace Message Unstable" defect condition. • Whenever the VT-De-Mapper block clears the "VT-Path Trace Message Unstable" defect condition. ` 0 - Disables the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt. ` 1 - Enables the "Change of VT Path Trace Message Unstable Defect Condition" Interrupt. Bit 4 - New VT Path Trace Message Interrupt Enable: This READ/WRITE bit-field permits the user to either enable or disable the "New VT Path Trace Message" Interrupt. If the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt whenever it has "accepted" a new "VT Path Trace Message" via the incoming VT-data-stream. ` 0 - Disables the "New VT Path Trace Message" Interrupt. ` 1 - Enables the "New VT Path Trace Message" Interrupt Bit 3 - Change of TIM-V Defect Condition Interrupt Enable: This READ/WRITE bit-field permits the user to either enable or disable the "Change of TIM-V Defect Condition" Interrupt. If the user enables this interrupt, then the VT-De-Mapper block will generate this interrupt in response to either of the following events. • Whenever it declares the TIM-V Defect Condition • Whenever it clears the TIM-V Defect Condition ` 0 - Disables the "Change of TIM-V Defect Condition" Interrupt ` 1 - Enables the "Change of TIM-V Defect Condition" Interrupt Bits 2 - 0 - Unused: 320 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 458: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - VT-PATH TRACE BUFFER CONTROL REGISTER (ADDRESS = 0XND71, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 Reserved BIT 5 BIT 4 BIT 3 BIT 2 Unused Receive VT Path Trace Message Buffer Select VT Path Trace Message Accept Threshold VT Path Trace Message Type BIT 1 BIT 0 VT Path Trace Message Length[1:0] R/W R/W RUR RUR RUR R/O R/O R/O 0 0 0 0 0 0 0 0 Bit 7 - 6 - Reserved For Normal Operation, please set these two bit-fields to "0". Bit 5 - Unused Bit 4 - Receive VT Path Trace Message Buffer Select: This READ/WRITE bit-field permits a user to specify which of the following "Receive VT Path Trace Message" buffer segments that the Microprocessor will read out whenever it reads out the contents of the Receive Path Trace Message buffer. a. The "Actual" Receive VT Path Trace Message Buffer. The "Actual" Receive VT Path Trace Message Buffer contains the contents of the most recently received (and accepted) VT Path Trace Messages via the incoming VT-data-stream. b. The "Expected" Receive VT Path Trace Message Buffer. The "Expected" Receive Path Trace Message Buffer contains the contents of the "VT Path Trace Message" that the user "expects" to receive. The contents of this particular buffer are usually specified by the user. ` 0 - Configures the chip to return the contents of the "Actual" Receive VT Path Trace Message" Buffer, whenever the user executes a READ to the "Receive VT Path Trace Message" Buffer. ` 1 - Configures the chip to return the contents of the "Expected" Receive VT Path Trace Message" Buffer, whenever the user executes a READ to the "Receive VT Path Trace Message" Buffer. Bit 3 - Receive VT Path Trace Message Accept Threshold This READ/WRITE bit-field permits a user to select the number of consecutive times that the "VT-De-Mapper" block must receive a given "VT Path Trace Message" before it is "validated" and loaded into the "Actual" Receive VT Path Trace Message Buffer, as described below. ` 0 - Configures the VT-De-Mapper block to "validate" the incoming VT Path Trace Message after it has received it the third time in succession. ` 1 - Configures the VT-De-Mapper block to "validate" the incoming VT Path Trace Message after it has received it the fifth time in succession. Bit 2 - Receive VT Path Trace Message Type This READ/WRITE bit-field permits the user to specify how the "VT-De-Mapper" block will locate the boundary of the incoming VT Path Trace Message (within the incoming VT-data-stream) as depicted below. ` 0 - Configures the VT-De-Mapper block to expect the "VT Path Trace Message" boundary to be denoted by a "Line Feed" character. ` 1 - Configures the VT-De-Mapper block to except the "VT Path Trace Message" boundary to be denoted by the presence of a "1" in the "MSB" (Most Significant bit) of the first byte (within the incoming VT Path Trace Message). In this case, all of the remaining bytes (within the incoming VT Path Trace Message) will each have a "0" within their MSBs. Bits 1 - 0 - VT Path Trace Message Length[1:0]: These READ/WRITE bit-fields permit the user to specify the length of the "Receive VT Path Trace Message that the "VT-De-Mapper" block will accept and load into the "Actual" Receive VT Path Trace Message Buffer. The relationship between the contents of these bit-fields and the corresponding "Receive VT Path Trace Message" Length is presented 321 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 below. VT PATH TRACE MESSAGE LENGTH[1:0] RESULTING VT PATH TRACE MESSAGE LENGTH (BYTES) 00 1 01 16 1X 64 TABLE 459: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER BYTE 1 (ADDRESS = 0XND72, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 Unused BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Auto Transmit AIS-V upon AIS-V Defect Auto Transmit AIS-V upon UNEQV Defect Unused Auto Transmit AIS-V upon LOP-V Defect Auto Transmit AIS-V upon PLM-V Defect Unused R/O R/O R/W R/W R/O R/W R/W R/O 0 0 0 0 0 0 0 0 Bits 7 - 6 - Unused: Bit 5 - Auto Transmit AIS-V upon AIS-V Defect: This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration that) it declares the AIS-V defect condition within the incoming VT-data-stream. ` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the AIS-V defect condition. ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the AIS-V defect condition. NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator, in response to this defect condition. Bit 4 - Auto Transmit AIS-V upon UNEQ-V Defect: This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration that) it declares the UNEQ-V defect condition within the incoming VT-data-stream. ` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the UNEQ-V defect condition. ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the UNEQ-V defect condition. NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator, in response to this defect condition. Bit 3 - Unused: Bit 2 - Auto Transmit AIS-V upon LOP-V Defect: This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration that) it declares the LOP-V defect condition within the incoming VT-data-stream. ` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the LOP-V defect condition. 322 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the LOP-V defect condition. NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator, in response to this defect condition. Bit 1 - Auto Transmit AIS-V upon PLM-V Defect: This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration that) it declares the PLM-V defect condition within the incoming VT-data-stream. ` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the PLM-V defect condition. ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the PLM-V defect condition. NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator, in response to this defect condition. Bit 0 - Unused: TABLE 460: CHANNEL CONTROL - VT-DE-MAPPER BLOCK - EGRESS DIRECTION - AUTO AIS CONTROL REGISTER BYTE 0 (ADDRESS = 0XND73, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 Auto Transmit AIS-V upon VT Path Trace Message Unstable Defect Auto Transmit AIS-V upon TIM-V Defect R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Reserved (Set to "[0, 0, 0, 0, 0]" for Normal Operation) BIT 0 Auto Transmit AIS-V Enable Bit 7 - Auto Transmit AIS-V upon VT Path Trace Message Unstable Defect: This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration that) it declares the VT Path Trace Message Unstable defect condition within the incoming VT-data-stream. ` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the VT Path Trace Message Unstable defect condition. ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the VT Path Trace Message Unstable defect condition. NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator, in response to this defect condition. Bit 6 - Auto Transmit AIS-V upon TIM-V Defect: This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator via the "Egress Direction" traffic (e.g., towards the Transmit T1/E1 LIU Block), anytime (and for the duration that) it declares the TIM-V defect condition within the incoming VT-data-stream. ` 0 - Does not configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the TIM-V defect condition. ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream" traffic) whenever it declares the TIM-V defect condition. 323 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 NOTE: The user must also set Bit 0 (Auto Transmit AIS-V Enable) within the "Channel Control - VT-De-Mapper Block Egress Direction - Receive VT Auto AIS Control" Register to "1" in order to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator, in response to this defect condition. Bits 5 - 1 - Reserved: Please set each of these bit-fields to "0" for normal operation. Bit 0 - Auto Transmit AIS-V Enable This READ/WRITE bit-field permits the user to configure the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the down-stream traffic) whenever (and for the duration that) it declares either the AIS-V, LOP-V, TIM-V, UNEQ-V, PLM-V or "VT Path Trace Message Unstable" defect conditions. ` 0 - Configures the VT-De-Mapper block to NOT automatically transmit the AIS-V indicator (via the "downstream traffic) upon declaration of any of the "above-mentioned" defect conditions. ` 1 - Configures the VT-De-Mapper block to automatically transmit the AIS-V indicator (via the "downstream traffic) upon declaration of any of the "above-mentioned" defect conditions. NOTE: The user must also set the corresponding bit-fields (within this register) to "1" in order to configure the VT-DeMapper block to automatically transmit the AIS-V indicator upon detection of a given alarm/defect condition. TABLE 461: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT J2 BYTE VALUE REGISTER (ADDRESS = 0XND76, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit J2 Byte Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 0 - Transmit J2 Byte Value[7:0]: These READ/WRITE bit-fields permit the user to have software control over the value of the J2 byte, within the outbound VT data-stream. If the user configures the VT-Mapper block to use this register as the source of the J2 byte, then it will automatically write the contents of this register into the J2 byte location, within each "outbound" VT multi-frame. This feature is enabled whenever the user writes the value "[1, 0]" into Bits 1 and 0 (Transmit VT-Path Trace Message Source[1:0]) within the "Channel Control - VT Mapper Block - Ingress Direction - VT Path Trace Message Control" Register. TABLE 462: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT N2 BYTE VALUE REGISTER (ADDRESS = 0XND77, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Transmit N2 Byte Value[7:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 0 - Transmit N2 Byte Value[7:0]: These READ/WRITE bit-fields permit the user to have software control over the value of the N2 byte, within the outbound VT data-stream. The VT-Mapper block will (unconditionally) use this register as the source of the N2 byte, then it will automatically write the contents of this register into the J2 byte location, within each "outbound" VT multiframe. 324 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS TABLE 463: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT VT-PATH TRACE MESSAGE CONTROL REGISTER (ADDRESS = 0XND79, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 Reserved BIT 4 BIT 3 Unused BIT 2 Transmit VT Path Trace Message Length[1:0] BIT 1 BIT 0 Transmit VT Path Trace Message Source[1:0] R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 0 Bits 7 - 6 - Reserved: NOTE: The user must set these two bits to "[0, 0]" for normal operation. Bit 5 - TxAIS: Bit 4 - Unused: Bits 3 - 2 - Transmit VT Path Trace Message Length[1:0]: These READ/WRITE bit-fields permit the user to specify the length of the VT Path Trace Message that the VT-Mapper block will repeatedly transmit to the remote VT PTE. The relationship between the contents of these bit-fields and the corresponding VT Path Trace Message Length is presented below. TRANSMIT VT PATH TRACE MESSAGE LENGTH[1:0] RESULTING VT PATH TRACE MESSAGE LENGTH (IN TERMS OF BYTES) 00 1 Byte 01 16 Bytes 1X 64 Bytes Bits 1 - 0 - Transmit VT Path Trace Message Source[1:0]: These READ/WRITE bit-fields permit the user to specify the source of the "outbound" VT Path Trace Message that will transported via the J2 byte channel (within the outbound VT-data-stream) as depicted below. TRANSMIT VT PATH TRACE MESSAGE SOURCE[1:0] RESULTING SOURCE OF THE VT PATH TRACE MESSAGE 00 Fixed Value:The VT-Mapper block will automatically set the J2 byte, within the each outbound VT-multi-frame to the value "0x01". 01 The Transmit VT Path Trace Message Buffer:The VT-Mapper Block will read out the contents within the "Transmit VT-Path Trace Message" Buffer, and will transmit this message to the remote VT PTE. 10 From the "Transmit J2 Byte Value[7:0]" Register:In this setting, the VT-Mapper block will read out the contents of the "Transmit J2 Byte Value Register, and will insert this value into the J2 byte-position within each outbound VT-multi-frame. 11 DO NOT USE 325 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 464: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 3 (ADDRESS = 0XND84, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Unused PLM-V RDI CODE[2:0] Transmit RDI-V upon PLM-V R/W R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 1 0 0 Bits 7 - 4 - Unused: Bits 3- 1 - PLM-V RDI Code[2:0]: These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the corresponding VT-De-Mapper block detects and declare the PLM-V defect condition. NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon PLM-V) within this register to "1". Bit 0 - Transmit RDI-V upon PLM-V This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code (as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that) the corresponding VT-De-Mapper block declares the PLM-V defect condition. ` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the PLM-V defect condition. ` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the PLM-V defect condition. TABLE 465: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 2 (ADDRESS = 0XND85, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 TIM-V RDI CODE[2:0] BIT 4 BIT 3 Transmit RDI-V upon TIM-V BIT 2 BIT 1 UNEQ-V RDI CODE[2:0] BIT 0 Transmit RDI-V upon UNEQ-V R/W R/W R/W R/W R/W R/W R/W R/W 1 1 0 0 1 1 0 0 Bits 7 - 5 - TIM-V RDI Code[2:0]: These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the corresponding VT-De-Mapper block detects and declare the TIM-V defect condition. NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon TIM-V) within this register to "1". Bit 4 - Transmit RDI-V upon TIM-V This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code (as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that) the corresponding VT-De-Mapper block declares the TIM-V defect condition. ` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the TIM-V defect condition. ` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the TIM-V defect condition. Bits 3 - 1 - UNEQ-V RDI Code[2:0]: 326 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the corresponding VT-De-Mapper block detects and declare the UNEQ-V defect condition. NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon UNEQ-V) within this register to "1". Bit 0 - Transmit RDI-V upon UNEQ-V This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code (as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that) the corresponding VT-De-Mapper block declares the UNEQ-V defect condition. ` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the UNEQ-V defect condition. ` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the UNEQ-V defect condition. TABLE 466: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 1 (ADDRESS = 0XND86, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 BIT 5 LOP-V RDI CODE[2:0] BIT 4 BIT 3 Transmit RDI-V upon LOP-V BIT 2 BIT 1 AIS-V RDI CODE[2:0] BIT 0 Transmit RDI-V upon AIS-V R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 Bits 7 - 5 - LOP-V RDI Code[2:0]: These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the corresponding VT-De-Mapper block detects and declare the LOP-V defect condition. NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon LOP-V) within this register to "1". Bit 4 - Transmit RDI-V upon LOP-V This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code (as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that) the corresponding VT-De-Mapper block declares the LOP-V defect condition. ` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the LOP-V defect condition. ` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the LOP-V defect condition. Bits 3 - 1 - AIS-V RDI Code[2:0]: These three READ/WRITE bit-field permits the user to specify the value that the VT-Mapper block will transmit, within the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) whenever (and for the duration that) the corresponding VT-De-Mapper block detects and declare the AIS-V defect condition. NOTE: In order to enable this feature, the user must set Bit 0 (Transmit RDI-V upon AIS-V) within this register to "1". Bit 0 - Transmit RDI-V upon AIS-V This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RDI Code (as configured in Bits 3 through 1 - within this register) towards the remote VT PTE whenever (and for the duration that) the corresponding VT-De-Mapper block declares the AIS-V defect condition. ` 0 - Configures the VT-Mapper block to NOT automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the AIS-V defect condition. ` 1 - Configures the VT-Mapper block to automatically transmit the RDI Code (via the K4 byte) whenever (and for the duration that) the corresponding VT-De-Mapper block declares the AIS-V defect condition. 327 PRELIMINARY XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REV. P1.0.6 TABLE 467: CHANNEL CONTROL - VT-MAPPER BLOCK - INGRESS DIRECTION - TRANSMIT RDI-V CONTROL REGISTER - BYTE 0 (ADDRESS = 0XND87, WHERE N RANGES IN VALUE FROM 0X01 TO 0X1C) BIT 7 BIT 6 RFI-V upon DS1/E1 RAI Enable BIT 5 BIT 4 Unused BIT 3 BIT 2 BIT 1 BIT 0 Transmit RDI-V Value[2:0] RDI-V Type RDI-V Insert Type R/W R/W R/W R/W R/W R/W R/W R/W 1 0 1 0 1 0 1 0 Bit 7 - RFI-V upon DS1/E1 RAI Enable: This READ/WRITE bit-field permits the user to configure the VT-Mapper block to automatically transmit the RFI-V indicator (within the outbound VT-data-stream) whenever (and for the duration) that the corresponding Ingress Direction Receive DS1/E1 Framer block declares the RAI defect condition. ` 0 - Does not configure the VT-Mapper block to automatically transmit the RFI-V indicator whenever (and for the duration) that the corresponding Ingress Direction Receive DS1/E1 Framer block declares the RAI defect condition. ` 1 - Configures the VT-Mapper block to automatically transmit the RFI-V indicator whenever (and for the duration) that the corresponding Ingress Direction Receive DS1/E1 Framer block declares the RAI defect condition. Bits 6 - 5 - Unused: Bits 4 - 2 - Transit RDI-V Value[2:0]: These three READ/WRITE bit-fields permits the user to specify the value that the VT-Mapper block will transmit, within the RDI-V bit-fields of the K4 byte (within each outbound VT-frame) regardless of any defects that the corresponding VT-De-Mapper block is (or is NOT) currently declaring. NOTE: The user MUST set bit 0 (RDI-V Insert Type) within this register to "1" in order to configure the VT-Mapper block to use these bit-fields as the "source" of the RDI-V value. Bit 1 - RDI-V Type This READ/WRITE bit-field permits the user to configure the VT-Mapper block to either support the "SRDI-V" (SingleBit - RDI-V) or "ERDI-V" (Extended - RDI-V) form of signaling. If the user opts to use only "Single-Bit" RDI-V, then the RDI-V indicator will only be transported via Bit 8 (RDI-V) within the V5 byte in a VT-data-stream. Conversely, if the user opts to use the "Extended" RDI-V, then the RDI-V indicator will be transported via both Bit 8 (RDI-V) within the V5 byte, and Bits 5, 6 and 7 within the Z7/K4 byte. ` 0 - Configures the VT Mapper block to use the SRDI-V form of signaling. ` 1 - Configures the VT-Mapper block to use the ERDI-V form of signaling. NOTE: This configuration setting only applies to the VT-Mapper block. If the user wishes to configure the VT-De-Mappe block to support either the "SRDI-V" or the "ERDI-V" form of signaling, then he/she must set Bit 0 (RDI-V Type) within the "Channel Control - VT-De-Mapper Block - Egress Direction - DS1/E1 Drop Control Register - Byte 2. Bit 0 - RDI-V Insert Type: This READ/WRITE bit-field permits the user to select the source of the RDI-V code word that the VT-Mapper block will transmit within the outbound VT-data-stream, as depicted below. In this case, the user has two options. • To configure the VT-Mapper block to transmit the appropriate RDI-V code (based upon defects that the corresponding VT-De-Mapper block declares). In this case, the VT-Mapper block will transmit the RDI-V codes, as configured in the "Channel Control - VT Mapper Block - Ingress Direction - Transmit RDI-V Control Register - Bytes 3 - 1" registers. • To configure the VT-Mapper block to use the value written into the "Transmit RDI-V Value[2:0]" bit-fields within this register. ` 0 - Configures the VT-Mapper block to transmit the appropriate RDI-V code (based upon defects that the corresponding VT-De-Mapper block declares). ` 1 - Configures the VT-Mapper block to use the value written into the "Transmit RDI-V Value[2:0]" bit-fields within this register. 328 PRELIMINARY REV. P1.0.6 XRT86SH328 28-CHANNEL DS1/E1 FRAMER/LIU WITH DS3 MUX & VT-MAPPER - SONET APPLICATIONS REVISIONS DATE REV # DESCRIPTION 09/09/06 P1.0.0 Initial issue of register information. 11/09/06 P1.0.5 Made edits to register map. 1/17/07 P1.0.6 Made edits to register map and register definitions. NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user’s specific application. While the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances. Copyright 2007 EXAR Corporation Datasheet January 2007. All effort hs been made to provide correct information in this data sheet, iIf discrepencies are found or more information is required please contact Exar Application Engineering at <[email protected]> Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited. 329