ETC XY2CE1A250

Components for safety applications
Emergency stop trip wire switches
Characteristics
References :
pages 3/17 to 3/22
Dimensions :
page 3/23
Environment
Products : XY2-CB : IEC 947-5-1, EN 60947-5-1, VDE 0660-200, CSA C 22-2 n° 14, prEN616
XY2-CE, CH, CB : IEC 947-5-1, EN 60 947-5-1, VDE 0660-200, EN 418, prEN616
Machine assemblies : XY2-CE, CH, CB : EN 60-204-1, EN292.
Product certifications
Special version
XY2-CB : CSA c 600 V heavy duty. XY2-CE : UL-CSA A 300-Q 300. XY2-CH : UL-CSA
Protective treatment
Ambient air temperature
Standard version : “TC”. Special version : “TH”
Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C
Vibration resistance
Shock resistance
XY2-CE : 10 gn (10…300 Hz) conforming to IEC 68-2-6 ; XY2-CH : 10 gn (10…150 Hz)
XY2-CE, CH : 50 gn (duration 11 ms) conforming to IEC 68-2-27
Electric shock protection
Degree of protection
Mechanical durability
Length of protected zone (trip wire)
Class I conforming to IEC 536 and NF C 20-030
XY2-CB : enclosure IP 22, contact housing IP 65, conforming to IEC 529 and NF C 20-010
XY2-CE, CH : IP 65
XY2-CE, CH (Emergency stop) : 10,000 operating cycles
XY2-CH : ≤ 15 metres, XY2-CE : ≤ 50 metres, XY2-CB : 100 metres and 200 metres
Cable entry
Entries for cable glands with maximum capacity of 12 mm : XY2-CB : 1 entry, XY2-CE, CH : 3 entries
Contact block characteristics
Rated operational characteristics
AC-15 : A 300 or Ue = 240 V, le = 3 A
DC-13 : Q 300 or Ue = 250 V, le = 0.27 A conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1
Nominal thermal current
10 A
Rated insulation voltage
XY2-CE, CH : Ui = 500 V degree of pollution 3 conforming to IEC 947-1, Ui = 300 V to UL 508, CSA C22-2 n° 14
XY2-CB : Ui = 500 V degree of pollution 3 conforming to IEC 947-1, Ui = 600 V conforming to CSA C22-2 n° 14
Rated impulse withstand voltage
XY2-CE, CH : U imp = 6 kV conforming to IEC 947-1, IEC 664
Positive operation
N/C with positive opening operation conforming to IEC 947-5-1 Section 3, EN 60 947-5-1
Contact operation
XY2-CB, CE, CH (Emergency stop) : N/C + N/C or N/C + N/O slow break
Resistance across terminals
≤ 25 mΩ conforming to NF C 93-050 method A or IEC 255-7 category 3
Terminal referencing
Conforming to CENELEC EN 50013
Operational voltage
c 24…380 V
Short-circuit protection
XY2-CB, CE, CH : 10 A cartridge fuse type gG (gl) conforming to IEC 269
Rated operational power
(Electrical durability)
Operating rate : 3600 operating
cycles/hour
Load factor : 0.5
XY2-CB
Conforming to IEC 947-5-1 Appendix C
Utilisation categories AC-15 and DC-13
a.c. supply c 50…60 Hz
Power broken in VA (1)
p Inductive circuit
Voltage V
p
VA
24
250
48
250
127
500
d.c. supply a
Power broken in W (1)
p Inductive circuit
Voltage V
24
p Inductive circuit
220
500
1
Ithe
12/24/48 V
0,5
220 V
127 V
0,1
2
1
48
p
W
50
100
(1) For 1 million operating cycles
3
4
10A
5
Current in A
120
Voltage V
24
48
120
100
p
15
23
30
W
Screw clamp terminals, clamping capacity : min. 1 x 0.5 mm2, max. 1 x 2.5 mm 2 or 2 x 1.5 mm 2
Cabling
3/16
XY2-CE, CH
Conforming to IEC 947-5-1 Appendix C
Utilisation categories AC-15 and DC-13
a.c. supply c 50…60 Hz
Millions of operating cycles
3
Conforming to standards
Te
Components for safety applications
Emergency stop trip wire switches
Characteristics :
page 3/16
Dimensions :
page 3/23
References
Latching Emergency stops without indicator (1) (cable not included)
Cable
Reference
anchor point
Length of cable ≤ 15 metres. Distance between cable supports : 5 metres
XY2-CH13250
Contact
Reset
N/C + N/O
slow break
By booted
pushbutton
RH side or
LH side
XY2-CH13250H29
0.865
By key release
pushbutton (key n° 421) (2)
RH side or
LH side
XY2-CH13450H29
0.910
By booted
pushbutton
RH side or
LH side
XY2-CH13270H29
0.865
By key release
RH side or
XY2-CH13470H29
pushbutton (key n° 421) (2)
LH side
Length of cable ≤ 50 metres. Distance between cable supports : 10 metres
0.910
N/C + N/O
slow break
By booted
pushbutton
RH side
LH side
XY2-CE1A250
XY2-CE2A250
1.450
1.450
N/C + N/C
slow break
By booted
pushbutton
RH side
LH side
XY2CE1A270
XY2-CE2A270
1.450
1.450
N/C + N/O
slow break
By key release
pushbutton (key n° 421) (2)
RH side
LH side
XY2-CE1A450
XY2-CE2A450
1.465
1.465
N/C + N/C
By key release
RH side
XY2-CE1A470
slow break
pushbutton (key n° 421) (2)
LH side
XY2-CE2A470
Length of cable ≤ 100 metres. Distance between cable supports : 20 metres
1.470
1.470
N/C + N/C
slow break
XY2-CE1A250
Weight
kg
N/C + N/O
From inside
LH side
XY2-CB10
slow break
enclosure
RH side
XY2-CB20
Length of cable ≤ 2 x 100 metres. Distance between cable supports : 20 metres
15.000
15.000
N/C + N/O
slow break
25.000
From inside
enclosure
RH side and
LH side
XY2-CB30
Latching Emergency stops with indicator (cable not included)
Contact
XY2-CB30
Reset
Supply
Cable
Reference
(direct)
anchor
Bulb included
point
Length of cable ≤ 50 metres. Distance between cable supports : 10 metres
Weight
2 N/C + N/O
slow break
Contact
RH side
XY2-CE1A297
LH side
XY2-CE2A297
Supply
Cable
Reference
(via integral
anchor
transformer) (3)
point
Length of cable ≤ 100 metres. Distance between cable supports : 20 metres
1.470
1.470
Weight
N/C + N/O
slow break
By booted
pushbutton
Reset
From inside
enclosure
kg
230 V
kg
24 V/6 V
LH side
RH side
XY2-CB11
XY2-CB21
15.600
15.600
127 V/6 V
LH side
RH side
XY2-CB13
XY2-CB23
15.600
15.600
LH side
XY2-CB14
RH side
XY2-CB24
Length of cable ≤ 2 x 100 metres. Distance between cable supports : 20 metres
15.600
15.600
N/C + N/O
slow break
220 V/6 V
From inside
enclosure
24 V/6 V
RH side and
LH side
XY2-CB31
25.600
127 V/6 V
RH side and
LH side
XY2-CB33
25.600
220 V/6 V
RH side and XY2-CB34
25.600
LH side
(1) These Emergency stops are also available fitted with an indicator, see ordering forms for XY2-CH and XY2-CE trip
wire switches on pages 3/18 and 3/19.
(2) Ø 30 mm mushroom head key release pushbutton. Locking and key withdrawal in the rest (unactuated) position.
(3) BA 7s - 6 V bulb included.
Other versions
See order forms, pages 3/18 and 3/19.
XY2-CE with reset by Ø 40 mm mushroom head pushbutton or with integral cable tensioner & support.
Please consult your local Customer support centre.
Te
3/17
3
Components for safety applications
Emergency stop trip wire switches
Complete units, assembled by Telemecanique
Order form (specimen suitable for photocopying)
Customer
Company
Order N°
Schneider Electric
Delivery date Sales office - Subsidiary Co.
Order N°
How to use this order form :
- indicate the number of Emergency stop switches required,
- complete the basic reference.
Reference
Number of identical
Emergency stop
trip wire switches
XY2-CH
Model
Emergency stop
(latching)
3
1
Degree of protection
IP 65 (standard bellows) without tensioner
IP 65 (silicone bellows) without tensioner
IP 65 (standard bellows) with integral tensioner
IP 65 (silicone bellows) with integral tensioner
1
2
3
4
Type of reset
Emergency stop (1)
Reset by
spring return
pushbutton
Flush
Booted
Mushroom head, Ø 30 mm
1
2
3
Key release mushroom head, Ø 30 mm (key n° 421)
Key release mushroom head, Ø 30 mm (key n° 455)
Pull knob
Key release mushroom head, Ø 30 mm (2)
4
5
6
9
Contact block for Emergency stop function (3)
Slow break
1 N/C + N/O (N/O staggered)
1 N/C + N/C
Indicator
Without indicator
With 24 V direct supply indicator
With 48 V direct supply indicator
With 130 V direct supply indicator
With 230 V direct supply indicator
Increased protective treatment against corrosion
(1) Opening of a circuit + mechanical latching in the open position.
(2) Other key numbers
458A
2123E
3423A
(3) Emergency stop
3/18
Te
520
1242A
1243E
1344A
1422A
2132E
3112E
3113A
3122A
3123A
3432A
4241A
trip wire switches can only be fitted with slow break contact blocks.
5
7
0
3
4
5
7
TK
1431E
3233A
Components for safety applications
Emergency stop trip wire switches
Complete units, assembled by Telemecanique
Order form (specimen suitable for photocopying)
Customer
Company
Order N°
Schneider Electric
Delivery date Sales office - Subsidiary Co.
Order N°
How to use this order form :
- indicate the number of Emergency stop switches required,
- complete the basic reference.
Reference
Number of identical
Emergency stop
trip wire switches
Model
Emergency stop
(latching)
XY2-CE
Anchor point on RH side, standard force
Anchor point on LH side, standard force
Anchor point on RH side, light force
Anchor point on LH side, light force
3
1
2
5
6
Degree of protection and “cable under tension” indicator
IP 65 (standard bellows) without indicator
IP 65 (silicone bellows) without indicator
IP 65 (standard bellows) with indicator
IP 65 (silicone bellows) with indicator
A
C
D
E
Type of reset
Emergency stop (1)
Reset by
spring return
pushbutton
Flush
Booted
Mushroom head, Ø 30 mm
Key release mushroom head, Ø 30 mm (key n° 421)
Key release mushroom head, Ø 30 mm (key n° 455)
Pull knob
Key release mushroom head, Ø 30 mm (2)
1
2
3
4
5
6
9
Contact block(s) for Emergency stop function (3)
Slow break
1 N/C + N/O
1 N/C + N/C
2 N/C + N/O (compulsory with pilot light) (4)
5
7
9
Pilot light
Without pilot light
With 24-48-130 V direct supply pilot light, bulb not included (provide for 2 contact blocks)
With 230 V direct supply pilot light, bulb included (provide for 2 contact blocks)
Increased protective treatment against corrosion
(1) Opening of N/C contact + mechanical latching in the open position.
(2) Other key numbers
0
6
7
TK
458A
520
1242A
1243E
1344A
1422A
1431E
2123E
2132E
3112E
3113A
3122A
3123A
3233A
3423A
3432A
4241A
(3) Emergency stop trip wire switches can only be fitted with slow break contact blocks.
(4) The use of a pilot light means selecting a switch fitted with 2 N/C + N/O contacts : XY2-CEiii9
Te
3/19
Components for safety applications
Emergency stop trip wire switches
References of accessories and spare parts
Dimensions :
page 3/23
Description
Application
Diameter
mm
Length
m
Reference
Weight
kg
Galvanised
cables with
red sheath
For XY2-CH
3.2
10.5
XY2-CZ301
0.280
15.5
XY2-CZ3015
0.410
25.5
XY2-CZ302
0.690
50.5
XY2-CZ305
1.360
100.5
XY2-CZ310
2.700
15.5
XY2-CZ1015
0.850
25.5
XY2-CZ102
1.400
50.5
XY2-CZ105
2.750
100.5
XY2-CZ110
5.500
Sold in
lots of
Unit
reference
XY2-CZ402
XY2-CZ503
3
For XY2-CH,
XY2-CE and
XY2-CB
XY2-CZ524
5
XY2-CZ601
Description
Type
Application
Turnbuckles
M6 x 60
+ locknut
All models
1
except XY2-CH (1)
XY2-CZ402
0.060
M8 x 70
+ locknut
All models
1
except XY2-CH (1)
XY2-CZ404
0.100
Single
Cable
Ø 3 to 5 mm
10
XY2-CZ503
0.007
Double
Cable
Ø 3 to 5 mm
10
XY2-CZ513
0.016
Clamp
Cable Ø 3.2 mm
10
XY2-CZ523
0.050
Cable Ø 5 mm
10
XY2-CZ524
0.080
Fixed
All models
10
XY2-CZ601
0.030
Swivelling
All models
1
XY2-CZ602
0.130
Pulley bracket
All models
1
XY2-CZ705
0.060
Cable Ø 5 mm max.
All models
1
XY2-CZ706
0.002
Cable Ø 3.2 mm
10
XY2-CZ701
0.002
Cable Ø 5 mm
10
XY2-CZ704
0.010
For XY2-CE
1
XY2-CZ702
0.080
For XY2-CH
1
XY2-CZ703
0.035
For XY2-CB
1
XY2-CZ707
0.080
XY2-CZ602
Cable grips
XY2-CZ705
Cable supports
Weight
kg
XY2-CZ706
XY2-CZ701
Pulley
Cable end
protectors
End springs
XY2-CZ702
Documentation
Description
Installation manual
For use
with
Reference
All XY2-C
XCOM2512
trip wire switches
(1) Emergency stop trip wire switches XY2-CH incorporate a cable tensioner as standard.
3/20
Te
Weight
kg
0.200
Components for safety applications
Emergency stop trip wire switches
References of accessories and spare parts
Dimensions :
page 3/23
Fitting kits
Contents
of kit
Reference
mm
Length
of cable
m
–
–
XY2-CZ917
0.612
Kit comprising :
For XY2-CH
- 1 galvanised cable, Ø 3.2 mm,
length according to that selected,
- 1 cable grip XY2-CZ523,
- 1 end spring XY2-CZ703
3.2
10
XY2-CZ9310
0.415
For XY2-CH
3.2
15
XY2-CZ9315
0.535
Kit comprising :
For XY2-CE
3.2
- 1 galvanised cable, Ø 3.2 mm,
length according to that selected,
- 4 cable grips XY2-CZ523,
- 1 turnbuckle XY2-CZ404,
- 1 cable support XY2-CZ601,
- 3 cable end protectors
XY2-CZ701,
For XY2-CE/CB 3.2
- 1 end spring XY2-CZ702
25
XY2-CZ9325
1.250
50
XY2-CZ9350
1.980
Kit comprising :
For XY2-CE
5
- 1 galvanised cable, Ø 5 mm,
length according to that selected,
- 4 cable grips XY2-CZ524,
- 1 turnbuckle XY2-CZ404,
- 1 cable support XY2-CZ601,
- 3 cable end protectors
XY2-CZ704,
For XY2-CE/CB 5
- 1 end spring XY2-CZ702
25
XY2-CZ9525
1.905
50
XY2-CZ9550
3.280
Tensioner
+ bracket
XY2-CZ917
Other versions
Application
For XY2-CE
Diameter
Weight
kg
Padlocking kit (for up to 3 padlocks) for reset pushbutton.
Please consult your local Customer support centre.
Te
3/21
3
Components for safety applications
Emergency stop trip wire switches
References of spare parts
XY2-CZiiii
3
Description
Type
Reference
Reset
pushbutton
(blue)
spring return,
for XY2-CE
and XY2-CH
Flush with “R” marking on push
ZA2-BA639
0.030
Booted
ZA2-BP6
0.025
Mushroom head, Ø 30 mm
ZA2-BC64
0.045
Key release mushroom head, Ø 30 mm (key n° 421)
ZA2-BS06212
0.090
Key for latching N° 421
mushroom head
reset pushbutton
Q99900911
0.006
Head assembly
for pilot light
Yellow lens, for XY2-CE and XY2-CH
ZA2-BV05
0.015
Lens for
pilot light
Yellow, for XY2-CE and XY2-CH
ZB2-BV015
0.003
Pilot lights
Yellow, for XY2-CH
24 V
XY2-CZ0024
0.035
48 V
XY2-CZ0048
0.035
130 V
XY2-CZ0130
0.035
230 V
XY2-CZ0230
0.035
Description
Type
Incandescent
bulbs
BA 9s
base fitting
max. Ø 11 mm
length 28 mm
for XY2-CE
Screw
base fitting
max. Ø 17 mm
length 34 mm
for XY2-CH
Dust and
damp
protecting
bellows
XY2-CZ901
Tensioner
XY2-CZ203
3/22
Te
Sold in
lots of
Unit
reference
Weight
kg
24 V - 2.6 W
10
DL1-CE024
0.002
48 V - 2.6 W
10
DL1-CE048
0.002
130 V - 2.6 W
10
DL1-CE130
0.002
24 V - 6 W
10
DL1-AA024
0.004
48 V - 6 W
10
DL1-AA048
0.004
130 V - 6 W
10
DL1-AA127
0.004
230 V - 6 W
10
DL1-AA220
0.004
DL1-GA006
0.002
BA 7s base fitting
for XY2-CB
6 V - 200 mA
For XY2-CE
Polychloroprene
1
XY2-CZ901
0.017
Silicone
1
XY2-CZ904
0.005
Polychloroprene
1
XY2-CZ902
0.017
Silicone
1
XY2-CZ903
0.005
–
1
XY2-CZ203
0.095
For XY2-CH
XY2-CZ902
Weight
kg
For XY2-CE
Components for safety applications
Emergency stop trip wire switches
Dimensions
Characteristics :
page 3/16
References :
pages 3/17 to 3/22
iii
XY2-CEi
i Ai
i i i + XY2-CZ917
XY2-CEi
i Ai
229 (2)
105 (2)
52
20
195
120
243
44
6
12
63
142
Ø
(1)
(1)
(1)
31
23
25
82
61
3
(1) 1 tapped entry for cable gland of maximum capacity 12 mm
(2) Maximum extension
Ø : 4 elongated holes Ø 6 mm
XY2-CBi
ii
XY2-CH13i
i 50H29
(1)
208
Ø
197
458
265
201 (1)
48...56
68
121
56
40
55 (1)
(1) Maximum extension
Ø : 2 elongated holes Ø 8 mm
20 mm ISO entries
112
4xØ9
(3)
=
155 (2)
210
=
240
(1) 2 access points for operating cable
(2) + 125 mm for opening of cover
(3) Cable gland, maximum capacity 12 mm
XY2-CZ705
XY2-CZ706
Ø9
55
53
M8
Te
3/23