ETC ZN458A

THIS DOCUMENT IS FOR MAINTENANCE
PURPOSES ONLY AND IS NOT
RECOMMENDED FOR NEW DESIGNS
DS3025 - 2.1
ZN458
2.45V PRECISION REFERENCE REGULATOR
The ZN458 is a monolithic integrated circuit providing a
precise stable reference source of 2.45V in a two lead package without the need for an external shaping capacitor.
+VE
-VE
FEATURES
■
Guaranteed 5mV Maximum Deviation over Full
Temperature Range
■
Low Temperature Coefficient 0.003%/°C
■
Low Slope Resistance - 0.1 Ohms
■
Very Good Long Term Stability - 10ppm
■
Low Noise - 10 microvolts
■
Internally Shaped
■
Tight Tolerance ±1.43%
■
Two Pin Package
■
Wide Operating Current 2-120mA
CM2
Fig.1 Pin connection - bottom view
VS
VS - VREF
R=
IREF
R
ABSOLUTE MAXIMUM RATINGS
Dissipation
Operating temperature range
Storage temperature range
-20°C to +70°C
-55°C to +150°C
ORDERING INFORMATION
TC
(ppm/°C)
Temperature
range
ZN458
99
-20°C to +70°C
ZN458A
49
-20°C to +70°C
ZN458B
29
-20°C to +70°C
Device
VREF
+VE
300mW
AV
BAND
GAP
REFERENCE
-VE
Fig.2 Circuit diagram
GND
ZN458
ELECTRICAL CHARACTERISTICS (at Tamb = 25°C unless otherwise specified)
Symbol
Min.
Typ.
Max.
Units
Output voltage
VREF
2.42
2.45
2.49
V
Slope resistance
RREF
-
0.1
0.2
Ω
Reference current
IREF
2.0
-
120
mA
10
∆VREF
-
6
4
22
11
6.5
mV
mV
RMS noise voltage 1Hz-10kHz
-
10
-
µV
VREF drift at 70°C
-
±10
-
ppm/1000
Parameter
Maximum change
in VREF
ZN458
ZN458A
ZN458B
Test conditions
Measured at 2mA
-20 to +70°C
hours
DYNAMIC IMPEDANCE (ohms)
10
IREF = 2mA
1.0
IREF = 20mA
0.1
0.1
1.0
10
FREQUENCY (kHz)
Fig.3 Dynamic impedance
2
100
ZN458
10
CHANGE IN REFERENCE VOLTAGE, δV (mV)
8
FORWARD CURRENT (A)
10-1
10-2
10-3
10-4
0.4
0.8
1.2
1.6
2.0
2.4
FORWARD VOLTAGE (V)
2
0
-2
-4
ZN458
-6
-8
5
5
4
4
3
2
1
0
-1
-2
-3
ZN458A
-4
-5
0
10
20
30
40 50
60
TEMPERATURE (°C)
70
0
10
20
30
40
50
60
TEMPERATURE (°C)
70
80
Fig.5 Temperature characteristic (typical)
CHANGE IN REFERENCE VOLTAGE, δV (mV)
CHANGE IN REFERENCE VOLTAGE, δV (mV)
4
-10
2.8
Fig.4 Forward characteristic
6
80
Fig.6 Temperature characteristic (typical)
3
2
1
0
-1
-2
ZN458B
-3
-4
-5
0
10
20
30
40
50
60
TEMPERATURE (°C)
70
80
Fig.7 Temperature characteristic (typical)
3
ZN458
140
120
100
80
IREF (max.) 75
(mA)
60
40
20
0
-30
-20
-10
0
10
20 25 30
40
AMBIENT TEMPERATURE (C)
Fig.8 Derating curve
4
50
60
70
ZN458
5
ZN458
HEADQUARTERS OPERATIONS
GEC PLESSEY SEMICONDUCTORS
Cheney Manor, Swindon,
Wiltshire SN2 2QW, United Kingdom.
Tel: (0793) 518000
Fax: (0793) 518411
GEC PLESSEY SEMICONDUCTORS
P.O. Box 660017
1500 Green Hills Road,
Scotts Valley, California 95067-0017,
United States of America.
Tel: (408) 438 2900
Fax: (408) 438 5576
CUSTOMER SERVICE CENTRES
• FRANCE & BENELUX Les Ulis Cedex Tel: (1) 64 46 23 45 Fax : (1) 64 46 06 07
• GERMANY Munich Tel: (089) 3609 06-0 Fax : (089) 3609 06-55
• ITALY Milan Tel: (02) 66040867 Fax: (02) 66040993
• JAPAN Tokyo Tel: (03) 5276-5501 Fax: (03) 5276-5510
• NORTH AMERICA Integrated Circuits and Microwave Products Scotts Valley, USA
Tel (408) 438 2900 Fax: (408) 438 7023.
Hybrid Products, Farmingdale, USA Tel (516) 293 8686 Fax: (516) 293 0061.
• SOUTH EAST ASIA Singapore Tel: (65) 3827708 Fax: (65) 3828872
• SWEDEN Stockholm, Tel: 46 8 702 97 70 Fax: 46 8 640 47 36
• UK, EIRE, DENMARK, FINLAND & NORWAY
Swindon Tel: (0793) 518510 Fax : (0793) 518582
These are supported by Agents and Distributors in major countries world-wide.
© GEC Plessey Semiconductors 1994 Publication No. DS3025 Issue No. 2.1 January 1994
This publication is issued to provide information only which (unless agreed by the Company in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded
as a representation relating to the products or services concerned. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. The Company
reserves the right to alter without prior knowledge the specification, design or price of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user's responsibility to fully determine the performance and suitability of any equipment using such information
and to ensure that any publication or data used is up to date and has not been superseded. These products are not suitable for use in any medical products whose failure to perform may result in significant injury
or death to the user. All products and materials are sold and services provided subject to the Company's conditions of sale, which are available on request.
6