LUGUANG ZTA4.0MG

ZTA4.0MG
SCOPE
(范围)
This
2.
3.
specification is applied to the ceramics resonator used for microcomputer
(本规格书适用于微电子用陶瓷谐振器)
MODEL NAME
(产品名称)
Part No. (产品号)
Customer`s Part No.(顾客产品号)
Drawing No.(图号)
ZTA4.0MG
/
JYD-083
DIMENSIONS
(尺寸)
10.0 (MAX)
6.0
Z4.00M
)
X
A
M
(
1.
±
5.0
0.5±0.1
1.0
5.0±0.3
0.3±0.1
4.0 (MAX)
Materials(材料)
Terminal(引脚)
Sn plated on Cu(铜镀锡)
Coating(涂料)
Epoxy Resin(环氧树脂)
Unit(单位):mm
http://www.luguang.cn Email:[email protected]
ZTA4.0MG
4.
ELECTRICAL CHARACTERISTICS
(电气性能)
Item
(项目)
Requirements
(要求)
1
Oscillation Frequency(Fosc)
(振荡频率)
2
Frequency Tolerance
(频率公差)
Fosc±0.5 % (MAX)
3
Resonator Impedance
(谐振阻抗)
30 Ω (MAX)
4
Operating Temp. Range
(工作温度范围)
-25℃~+85℃
5
Temperature Stability
(温度稳定性)
±0.3% (MAX)
(-25℃~+85℃)
6
Insulation Resistance
(绝缘阻抗)
100MΩ min (D.C. 100V)
7
Aging(10 years)
(10 年老化率)
±0.3 %
8
Storage Temp. Range
(贮存温度范围)
-40℃~+85℃
9
Test Temp.&Humi.Condition
(测试温、湿度条件)
+10℃~+30℃、40%~80%
4.00
MHZ
5. TEST CIRCUIT
(测试电路)
Unless any necessity to measure under a standard condition(Temp:20±2℃.Humi.:65±5%)is
occurred.( 必要时标准测量条件为温度 20± 2℃,相对湿度 65± 5%)
VDD
IC
IC
Output
1MΩ
C1
IC:1/6CD4069UBE×2
C2
VDD= +5V(DC)
C1=C2=30pF
http://www.luguang.cn Email:[email protected]
ZTA4.0MG
6.
PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
(物理及环境特性)
Test Item
(试验项目)
1
Lead Strength
(引脚强度)
Lead Pulling
(引脚拉力)
Lead Bending
(引脚弯曲)
Condition of Test
(试验条件)
Force of 0.5kg is applied to each lead in axial
direction for 10sec..(沿每个引脚轴向施加 0.5kg 力
保持 10 秒钟)
When force of 0.25kg is applied to each lead in axial
direction.the lead shall folded up to 90° from the
axial direction and folded back to the axial direction.
(沿引脚轴向施加 0.25kg 力的时候把引脚折弯 90
Requirements
(要求)
No mechanical
damage and the
measured values
shall meet Table
1.(无机械损伤,
测量值满足表 1
要求)
度后再折回原形)
Lead terminals are immersed in resin for 5 seconds
and then immersing in a soldering bath(235±5℃)for
2
Solderability
(可焊性)
5±0.5sec.(引脚在助剂内浸 5 秒后再浸入 235±5℃
的锡炉内 5±0.5 秒)
The solder shall
coat at least 90%
of the surface of
terminal(引脚上
锡覆盖率≥90%)
After being placed in a chamber with 85℃ for 100
3
Storage in High
Temp.
(高温贮存)
hours and then being placed in natural condition for 1
hours, then measure.(85℃环境下存放 100 小时后取
出自然存放 1 小时测试)
After being placed in a chamber with -25℃ for 100
4
Storage in Low
Temp.
(低温贮存)
hours and then being placed in natural condition for 1
hours, then measure.(-25℃环境下存放 100 小时后
取出自然存放 1 小时测试)
The measured
value shall meet
Table 1(测量值满
足表 1 要求)
After being placed in a chamber
(Humi.:90~95%RH,Temp.:40±2℃) for 100
5
Humidity
(潮湿)
hours and then being placed in natural condition for 1
hours, then measure. (温度 40±2℃;湿度 90~95%的
环境下存放 100 小时后取出自然存放 1 小时测试)
http://www.luguang.cn Email:[email protected]
ZTA4.0MG
After temperature cycling of -55℃(30 minutes)to
+85℃(30 minutes)was performed 5 times,Resonator
6
Thermal Shock
(热冲击)
shall be measured after being placed in natural
condition for 1 hour(-55℃下 30 分钟到+85℃下 30
分钟循环 5 次后自然存放 1 小时测量)
Lead terminals are immersed up to 2. 0 ㎜ from the
root of terminals in solder bath of 265±5℃ for
7
Resistance to
soldering Heat
(耐焊接热)
10±1seconds, Resonator shall be measured after
being placed in natural condition for 1 hour.( 引脚距
根部 2mm 以下浸入 265±5℃的锡炉中 10±1 秒取出
自然存放 1 小时测量)
8
Random Drop
(自由跌落)
9
Vibration
(振动)
Resonator shall be measured after 3 times random
dropping from the hight of 1 m to concrete floor.(谐
振器从 1 米高向水泥地板自由跌落 3 次后测量)
Resonator shall be measured after being applied
vibration as below:(谐振器做如下振动后测量)
Vibration Freq.(振动频率): 10 Hz to 55 Hz
Amplitude(幅度): 1.5mm
Directions(方向): 3 axial directions(三轴向)
Time(时间): 1 hour/each direction(1 小时/向)
The measured
value shall meet
Table 1(测量值满
足表 1 要求)
Table 1(表 1)
Item
(项目)
Limit Value
(限定值)
Oscillation Frequency(Fosc)
(振荡频率)
≤±0.3%
Resonator Impedance
(谐振阻抗)
≤±10Ω
※ Note: The limits in the above table are referenced to the initial measurements.
(上表中的限定值参照初始测量值)