CPI 4CX10-000D

The 4CX10,000D/8171 is identical to the
4CX5000A/8170 except for its rated plate dissipation. Its increased capability, resulting in a larger
cooler, is most useful in linear applications where
plate dissipation is generally the limiting factor.
The larger cooler also allows the 4CX10,000D/8171
to be used in place of the 4CX5000A/8170 with
cooler operation at any given air flow rate.
Class of Operation
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
Maximum Ratings
Type of Service
Plate Voltage
(Volts)
Plate
Current
(Amps)
10,000 Watts
250 Watts
75 Watts
110 MHz
4.5
Thoriated Tungsten
7.5 Volts
75.0 Amps
Grounded Cathode
115.0 pf
20.5 pf
0.7 pf
Grounded Grid
53.0 pf
20.5 pf
0.1 pf
Forced Air
Special, Coaxial
SK-300A
SK-1306
--9.13 in; 232.00 mm
7.05 in; 179.00 mm
12.0 lb; 5.50 kg
T ypical Operation
Plate
Screen
Voltage Voltage
(Volts)
(Volts)
Plate
Current
(Amps)
Drive
Output
Power Power
(Watts) (kiloWatts)
C
RF power amplifier
7,500
3.0
7,500
500
2.8
150
16.0
C
RF power amplifier plate modulated
5,000
2.3
5,000
500
1.4
25
5.8
AB1
RF linear amplifier
7,500
4.0
7,500
1,500
3.3
---
15.95
AB1
AF amplifier or modulator (2 tubes)
7,500
4.0
7,500
1,500
6.7
---
31.9
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, Eimac Operation, 607 Hansen Way, Palo Alto, CA 94303
telephone : 1(800) 414-8823. fax : (650) 592-9988 | email : [email protected]
CPI | 4CX10,000D/ 8171
CPI | 4CW50,000J
4CX10,000D/8171