HAMLIN 59135-4-S-05A

www.hamlin.com
File E61760(N)
59135 High Temperature Flange Mount Features and Benefits
57135 Actuator
Features
Benefits
Applications
• 2 part magnetically operated
proximity sensor
• High temperature rated
• Cross-slotted mounting holes for
optimum adjustability
• Standard, high voltage or change
over contacts
• Customer defined sensitivity
• Choice of cable length and
connector
• No standby power requirement
• Operates through non-ferrous
materials such as wood, plastic or
aluminium
• Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
• Simple installation and adjustment
•
•
•
•
59135 Sensor
Position and limit sensing
Security system switch
Linear actuators
Door switch
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Form A
Normally
Open
Normally Open
High Voltage
Change
Over
Normally
Closed
Power
Watt - max.
1
2
3
4
10
10
5
Voltage
Switching
Vdc - max.
5
200
300
175
175
Breakdown
Current
Switching
Vdc - min.
250
450
200
200
A - max.
0.5
0.5
0.25
0.25
Resistance
Carry
A - max.
1.2
1.5
1.5
1.5
Contact, Initial
Ω - max.
0.2
0.2
0.2
0.2
Insulation
Ω - min.
1010
1010
109
109
pF - typ.
0.3
0.2
0.3
0.3
°C
-40 to +150
-20 to +150
-40 to +150
-40 to +150
Switch Type
Capacitance
Contact
Temperature
Operating
Storage
°C
-65 to +150
-65 to +150
-65 to +150
-65 to +150
Time
Operate
ms - max.
1.0
1.0
3.0
3.0
Release
ms - max.
1.0
1.0
3.0
3.0
Shock
11ms 1⁄2 sine
G - max.
100
100
50
50
Vibration
50-2000 Hz
G - max.
30
30
30
30
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 2
TABLE 3
TABLE 4
Termination Options:-
D
Cable Type:-
Sensitivity Options:Activate Distances are approximate
using Hamlin 57135 actuator
as illustrated
Switch AT before modification
Select Option
Switch
Type
1
2
3
4
20 AWG 19/32 FEP
UL1130/UL1332
S
Pull In
AT
Range
Normally Open 12-18
High Voltage
Change Over
15-20
Normally Closed
T
Activate
Distance
d
(in) mm
(.748)
19,0
(.650)
16,5
SELECT
OPTION
Standard Lengths
Pull In
AT
Range
17-23
20-25
U
Activate
Distance
d
(in) mm
(.709)
18,0
(.591)
15,0
Pull In
AT
Range
22-28
25-30
Activate
Distance
d
(in) mm
(.630)
16,0
(.531)
13,5
SELECT
OPTION
CABLE
LENGTH
01
(3,94) 100
02
(11,81) 300
03
(19,69) 500
04
(29,53) 750
05
(39,37) 1000
(in)
V
Pull In
AT
Range
27-33
Activate
Distance
d
(in) mm
(.591)
15,0
mm
DESCRIPTION
(2 WIRE VERSIONS ILLUSTRATED)
A or F
Tinned or untinned leads
B
Crimped terminals
C
6.35mm fastons
D
AMP MTE 2.54mm pitch
E
JST XHP 2.5mm pitch
ORDERING INFORMATION
N.B. 57135 actuator sold separately
Series 59135
Switch Type
Sensitivity
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Tel:
Tel:
Tel:
Tel:
59036
59135
Cable Length
Table 1
Table 2
Table 3
Termination
Table 4
+1 920 648 3000 • Fax: +1 920 648 3001 • Email: [email protected]
+44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: [email protected]
+49 (0) 6181 953660 • Fax: +49 (0) 6181 9536666 • Email: [email protected]
+33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: [email protected]
ISSUE No: 4 DATE: 1/5/3
34
X
X
XX
X
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.