MACOM 6-1415537-3

General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR6 A/B/C/V
n6
pole relay with force guided contacts according to EN 50205
insulation between all contacts
nReinforced
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays
F0206-EA
ZT
Approvals
VDE 128935, UL E214025, TUV 968/EL 350, CQC06017015576/77,
CCC 2012010304537809
Coil Data
Coil voltage range
Max. coil power
5 to 110VDC
1200mW or 800mW
Technical data of approved types on request
Contact Data
Contact arrangement 3 form A + 3 form B contacts
3 NO + 3 NC,
4 form A + 2 form B contacts
4 NO + 2 NC,
5 form A + 1 form B contacts
5 NO + 1 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO2,
AgSnO2 + 0.2μm Au
Contact style single contact, force guided
type A according to EN 50205
Min. recommended contact load
5V, 10mA
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min-1
Contact ratings, IEC60947-5-1,
on 2 form A (NO) contact
AC15-5A
DC13-6A
Mechanical endurance
10x106 operations
Coil versions, DC-coil 800mW
Coil
Rated
Operate
Release
Coil
Rated coil
codevoltagevoltagevoltage
resistancepower
VDCVDCVDC
Ω±10%
mW
K1212 9 0.9180800
K151511.3 1.5281801
K181813.5 1.8405800
K212116 2.1551800
K242418 2.4720800
K36 36 27 3.61620800
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil versions, DC-coil 1200mW
Coil
Rated
Operate
Release
Coil
Rated coil
codevoltagevoltagevoltage
resistancepower
VDCVDCVDC
Ω±10%1)mW
0055 3.80.5211190
0066 4.50.6301200
0099 6.80.9681191
012
12
9
1.2
120
1200
0181813.5 1.82701200
0212116 2.13681198
0242418 2.44801200
036
36
27
3.6
1080
1200
040
40
30
4.0
1333
1200
048
48
36
4.8
1920
1200
060
60
45
6
30001)1200
110
110
83
11
100801)1200
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
11-2012, Rev. 1112
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR6 A/B/C/V (Continued)
Insulation Data
Other Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Clearance/creepage
between open contacts
between contact and coil
between adjacent contacts
Insulation to EN 50178, type of insulation
between contact and coil
between adjacent contacts
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-25 to 70°C
Category of environmental Protection
IEC 61 810
RTIII
Weight30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging/unit
tube/10 pcs.
1500Vrms
4000Vrms
3000Vrms
microdisconnection
≥5.5/5.5mm
≥5.5/5.5mm
reinforced
reinforced
For more detailed information see product specification 2158003
Accessories
27E1079 SR6A and SR6B socket (1423991-1)
27E1081 SR6C socket (1423992-1)
24A243 Relay hold down clip (1423994-1)
For details see datasheet 1654787
Dimensions
SR6 A/B/C
SR6 V
S0367-DN
S0367-DU
PCB layout / terminal assignment
Bottom view
3 ​form A + 3 form B, 3 NO + 3 ​NC versions
SR6 A
4 ​form A + 2 form B, 4 NO + 2 ​NC versions
SR6 B
S0368-CA
S0368-CC
5 ​form A + 1 form B, 5 NO + 1 ​NC versions
SR6 C
S0368-CA
S0368-CB
S0368-CE
S0368-CD
4 ​form A + 2 form B, 4 NO + 2 ​NC versions
SR6 V
The design of the SR6 V allows
clearance/creepage of 5.5 ​mm
on the PCB.
S0368-CU
2
11-2012, Rev. 1112
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
S0368-CV
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR6 A/B/C/V (Continued)
Product code structure
Typical product code SR6A 4 012
Type
SR6 Relay with force guided contacts SR6
Contact arrangement
A 3 form A + 3 form B contacts (3 NO + 3 NC)
B 4 form A + 2 form B contacts (4 NO + 2 NC)
V 4 form A + 2 form B contacts (4 NO + 2 NC)
C 5 form A + 1 form B contacts (5 NO + 1 NC)
Contact material
4 AgSnO2 for 1200mW version
6 AgSnO2 + 0.2µm Au for 800mW version
Coil
Coil code: please refer to coil versions table (e.g. 024=24VDC)
Available types please see Part number table
Product code
Type
Arrangement Cont. material
Coil
Coil power
Alt. description
Part number
SR6A4005
6 pole
3 forrm A + 3 form B,
AgSnO2
5VDC
1200mW V23050-A1005-A5338-1415017-1
SR6A4012
relay with
3 NO + 3 NC
12VDC
V23050-A1012-A533
1-1415015-1
SR6A4021
force guided
contactts21VDC
V23050-A1021-A533
3-1415018-1
SR6A4024
contacts24VDC
V23050-A1024-A533
1415015-1
SR6A404848VDC
V23050-A1048-A533
6-1415018-1
SR6A406060VDC
V23050-A1060-A533
7-1415018-1
SR6A4110110VDC
V23050-A1110-A533
9-1415018-1
6-1415537-1
SR6A6K12
AgSnO2+Au12VDC 800mW
SR6A6K18
18VDC
6-1415537-3
SR6A6K24
24VDC
6-1415537-5
5VDC
1200mW V23050-A1005-A5421393260-1
SR6B4005
4 form A + 2 form B,
AgSnO2
SR6B4006
4 NO + 2 NC
6VDC
V23050-A1006-A542
1393260-2
SR6B4012 contacts12VDC
V23050-A1012-A542
1393260-4
SR6B4018
18VDC
V23050-A1018-A542
1393260-5
SR6B4021
21VDC
V23050-A1021-A542
1393260-6
SR6B4024
24VDC
V23050-A1024-A542
1393260-7
SR6B4040
40VDC
V23050-A1040-A542
1393260-9
SR6B4048
48VDC
V23050-A1048-A542
1-1393260-0
SR6B4060
60VDC
V23050-A1060-A542
1-1393260-1
SR6B4085
85VDC
V23050-A1085-A542
1-1393260-2
SR6B4110
110VDC
V23050-A1110-A542
1-1393260-3
SR6B6K12
AgSnO2+Au12VDC 800mW
7-1415537-6
SR6B6K15
15VDC
7-1415537-7
SR6B6K18
18VDC
7-1415537-8
SR6B6K21
21VDC
7-1415537-9
SR6B6K24
24VDC
8-1415537-0
12VDC
1200mW V23050-A1012-A5511-1415017-1
SR6C4012
5 form A + 1 form B,
AgSnO2
SR6C4024
5 No + 1 NC
24VDC
V23050-A1024-A551
1415017-1
SR6C4048 contacts48VDC
V23050-A1048-A551
2-1415019-1
SR6C4060
60VDC
V23050-A1060-A551
3-1415019-1
SR6C4110
110VDC
V23050-A1110-A551
5-1415019-1
SR6C6K24
AgSnO2+Au24VDC 800mW
9-1415537-4
SR6V6K12
4 form A + 2 form B,
12VDC
3-1415542-5
SR6V6K15
4 NO + 2 NC
15VDC
2-1415543-2
SR6V6K18 contacts18VDC 3-1415543-3
SR6V6K21
21VDC
4-1415542-4
SR6V6K24
24VDC
5-1415539-2
11-2012, Rev. 1112
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
3