SCHURTER 7025.5160

MAT
NON RESETTABLE FUSES
Special Fuse, 14 x 50 mm
DTCN · 500 VAC · 250 VDC · Time-Lag T
Description
References
- High Breaking Capacity
General Product Information
Time-Current Curves see last page
Standards
Weblinks
- DTCN: T/5920 CC
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Admissible Ambient Air Temp.
Climatic Category
Material: Tube
Unit Weight
Storage Conditions
Product Marking
500 VAC, 250 VDC
1 - 20 A
100 kA
Time-Lag T
-40 °C to 55 °C
40/055/21 acc. to IEC 60068-1
Ceramic
25 g
0 °C to 60 °C, max. 70% r.h.
Voltage Rating
Dimensions
Length
ø 14±0.2
50 mm
13
13
3
50 +1.5
Pre-Arcing Time
Rated Current In
1 A - 20 A
1
1.25 x In
min.
1.65 x In
max.
2.0 x In
min.
5.0 x In
min.
5.0 x In
max.
10.0 x In
min.
10.0 x In
max.
60 min
60 min
2.5 s
30 ms
2.5 s
8 ms
200 ms
www.schurter.com
MAT
NON RESETTABLE FUSES
Variants
Order Number
Rated Cur rent [A]
Rated Voltage [VAC]
Rated Vol- Breaking Voltage Drop
tage [VDC] Capacity 1.0 In typ [mV]
7025.5110
1
500
250
1)
7025.5120
2
500
250
1)
7025.5130
4
500
250
1)
7025.5140
6
500
250
1)
7025.5150
10
500
250
1)
110 l
7025.5170
15
500
250
1)
105
7025.5160
20
500
250
1)
100
1) 100 kA @ 500 VAC , p.f. ≥ 0.15 / 10 kA @ 250 VDC , L/R < 10 ms
Packaging Unit
2
Small Box Pack (10 pcs.)
www.schurter.com
1600 l
l
680 l
l
600 l
420 l
l
l
l
TIME-CURRENT CURVES
NON RESETTABLE FUSES
MAT
100000
10000
1000
Time in Seconds
100
10
1
0.1
0.01
0.001
1
Multiple of Rated Current In
3
www.schurter.com
10