ETC 70M

Dry Contact and Mechanical Relay Output Modules
FEATURES
• SPST, Normally Open
• UL Recognized, CSA Certified
(see Engineering Information)
• 1500 Vac Optical Isolation
• G5 Modules Provide Replaceable 5
x 20 mm Glass Fuse
• Built-in Status LED
• Lifetime Warranty
• Switch AC or DC with the Same
Module
• No Off-State Leakage Current
••
TUV R h e i n l a n d
70G-ODC/OAC
70-ODC/OAC
DIMENSIONS
70M-ODC/OAC
CIRCUITRY
For complete dimensional drawings, see pages
H-4 or H-5.
LOAD
FUSES
1
VAC/VDC
G5 Fuses are 5 Amp Littelfuse part number
217005 or equivalent.
LOAD
2
+VCC
3
AMP
INPUT
4
GROUND
5
Fuse and status LED in G5 modules only.
SPECIFICATIONS BY PACKAGE STYLE
Package Style
I/O Modules
Specifications
Units
Isolation Voltage1
Vibration2
Mechanical Shock3
Storage Temp. Range
Operating Temp. Range
Vrms
°C
°C
Std (70-)
Mini (70M-)
G5 (70G-)
1500
MIL-STD-202
MIL-STD-202
-40 to 125
-20 to 85
1500
MIL-STD-202
MIL-STD-202
-40 to 125
-20 to 85
1500
MIL-STD-202
MIL-STD-202
-40 to 125
-20 to 85
1
Field to logic and channel-to-channel if Grayhill racks are used.
MIL-STD-202, Method 204, 20 Gs, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz.
3
MIL-STD-202, Method 213, Condition F, 1500 Gs or IEC68-2-27, 11 mS, 15 gs.
2
H-11
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • http://www.grayhill.com
Dry Contact and Electromechanical Relay Output Modules
SPECIFICATIONS BY PART NUMBER
Standard and Miniature Modules
Type/Function
Grayhill Part Number
Miniature, Normally Open
Standard, Normally Open
Specifications
Maximum Line Voltage
Load Voltage Range
Maximum Contact Rating
Maximum Switching Current1
Maximum Carry Current1
Minimum Life Expectancy
@ 10 Vdc/10 mA
@ 48 Vdc/100 mA
@ 120 Vac/80 mA
@ 30 Vdc or 230 Vac/3A
Maximum Contact Resistance
Maximum Off-State Leakage
Maximum Turn-On Time2
Maximum Turn-Off Time2
Nominal Logic Voltage (Vcc)
Logic Voltage Range
Maximum Logic Supply Current
@ Nominal Vcc
Nominal Input Resistance (Rx)
Minimum Drop Out Voltage
Maximum Reverse Logic Voltage
70M-ODC5R
70-ODC5R
70-OAC5RLY
70M-ODC24R
70-ODC24R
Vdc/Vac
Vdc/Vac
W
A
A
100/120
0-100/0-120
10
0.5
1.0
110/250
0-110/0-250
90
3.0
5.0
100/120
0-100/0-120
10
0.5
1.0
Cycles
Cycles
Cycles
Cycles
mΩ
mA
mSec
mSec
Vdc
Vdc
200 x 106
500 x 103
500 x 103
—
250
.002
1
1
5
4.8-6.0
—
—
—
100 x 106
250
.002
11
11
5
4.8-6.0
200 x 106
500 x 103
500 x 103
—
250
.002
1
1
24
20-30
mA
Ω
Vdc
Vdc
10
500
2.5
-5
26
200
4.8
-5
16
1700
23
-5
70G-ODC5R
70G-OAC5RLY
Vdc/Vac
Vdc/Vac
W
A
A
100/120
0-100/0-120
10
0.5
1.0
110/250
0-110/0-250
90
3.0
5.0
100/120
0-100/0-120
10
0.5
1.0
Cycles
Cycles
Cycles
Cycles
mΩ
mSec
mSec
mA
Vdc
Vdc
200 x 106
500 x 103
500 x 103
—
250
1
1
.002
5
4.8-6.0
—
—
—
100 x 106
250
11
11
.002
5
4.8-6.0
200 x 106
500 x 103
500 x 103
—
250
1
1
.002
24
18-32
mA
Ω
Vdc
10
500
1
26
200
1
23
1200
23
Units
G5 Modules
Type/Function
Grayhill Part Number
G5 Fusible, Normally Open
Specifications
1
2
Units
Inductive loads require diode suppression or RC network.
Times include debounce.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
I/O Modules
Maximum Line Voltage
Load Voltage Range
Maximum Contact Rating
Maximum Switching Current1
Maximum Carry Current1
Minimum Life Expectancy
@ 10 Vdc/10 mA
@ 48 Vdc/100 mA
@ 120 Vac/80 mA
@ 30 Vdc or 230 Vac/3A
Maximum Contact Resistance
Maximum Turn-On Time2
Maximum Turn-Off Time2
Max. Off-State Leakage @ Max. Line
Nominal Logic Voltage (Vcc)
Logic Voltage Range
Max. Logic Supply Current
@ Nominal Vcc
Nominal Input Resistance (Rx)
Minimum Drop Out Voltage
70G-ODC24R
Available from your local Grayhill Distributors
For prices and discounts, contact a local Sales
Office, an authorized local Distributor, or Grayhill.
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • http://www.grayhill.com
H-12