ALLEN-BRADLEY 800Z-GL2245-K2

Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Specifications
Standards
EN574, EN954-1, IEC/EN60947-5-1,
IEC/EN60204-1
cULus, C-Tick, and CE marked for all
applicable directives
Approvals
Power Supply
Description
The general purpose Bulletin 800Z Zero-Force Touch Buttons are
designed for use by machine control systems requiring the use of
two hands. An interlinked sensor surface weaves two capacitive
sensors in offset planes for superior product sensitivity.
The 800Z touch buttons are ergonomically designed for ease of
operation. No force is required to operate the switch; simply
touching the surface of the switch will initiate an output. The 800Z
can detect the hand though most industrial gloves.
Relay Output
Transistor Output
Power Consumption
Relay Output
Transistor Output
Outputs
Relay Output
Transistor Output
Output Ratings
Relay Output
Transistor Output
Min. Switched Current/
Voltage (Relay Output)
Pollution Degree
Operating Temperature
Humidity
Enclosure Protection
Features
•
•
•
•
Zero Force to operate
Ergonomic design
EMC protection
Diagnostic LEDs
1.44W, 19.2VA
100mA at 24V DC = 2.23W (no load)
1 N.O. & 1 N.C.
PNP or NPN
See Load Life Curves
150mA
8mA/5V DC
2
-25°C to +55°C (-13° to +131°F)
95% RH
IP66 (NEMA 4/4X/13), 1200 psi
washdown
Material
Housing/Guard Valox 357
Gaskets BUNA-N
Relay Contacts AgSnO
Any position
5 wire (single common)
4 wire (single common)
The contour of the 800Z touch buttons serves two purposes; it
easily conforms to the shape of the hand while helping prevent
defeatability when two-hand control is needed.
Two bi-coloured diagnostic LEDs provide guidance during operation.
The power/fault LED blinks at different rates to provide diagnostic
information to the user. The 800Z detects the presence of a hand
during power-up, noise, and conductive film build-up over time.
10-40V DC, 20-30V AC, or 85-264V AC
10-30V DC
Mounting
Cable
Electrical Life
EM-Relay inductive load See Load Life Curves
Vibration
1.5mm (0.06in) 10-55Hz
Shock
100g,11ms half-sine
Load Life Curves for General Purpose Product Line
Relay Output—Maximum DC Load Breaking Capacity
Relay Output—Electrical Endurance
300
10
250V AC
200
6
10
Operations
DC Voltage
100
Resistive Load
50
40
30
cosϕ = 1
cosϕ = 0.7
cosϕ = 0.4
5
10
20
10
0.1 0.2 0.5
1
2
DC Current (A)
11-2
5
10
20
104
0
1
2
3
4
5
Switching Current (A)
6
7
8
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Product Selection
Mounting Hole
Size
Catalogue Number
Input Voltage Range and
Output Type
Guard
6ft Cabled—5-Wire
800Z-GF3065
No Guard
800Z-GF3065B
Black Guard
30.5 mm
Mounting Hole
800Z-GL3065
No Guard
10...40V DC and 20...30V AC Input
Relay Output
800Z-GL3065B
Black Guard
800Z-GF2065
No Guard
85...264V AC Input
Relay Output
800Z-GF2065B
Black Guard
22.5 mm
Mounting Hole
800Z-GL2065
No Guard
10...40V DC and 20...30V AC Input
Relay Output
800Z-GL2065B
Black Guard
Recommended standard cordset, 2m (6.5ft). See pages 15-12 and 15-10 for additional lengths..
5-Pin Mini QD
5-Pin Micro QD
800Z-GF3Q5
800Z-GF3Q5B
800Z-GL3Q5
800Z-GL3Q5B
85...264V AC Input
Relay Output
800Z-GF2Q5
800Z-GF2Q5B
800Z-GL2Q5
800Z-GL2Q5B
889D-F5AC-2
889N-F5AE-6F
Use the configurator below to build an 800Z touch button to suit your application.
800Z – G
L
3
065
B
a
b
c
d
e
a
c
d
Input Voltage and Output Type
Electrical Connection
Guard Option
Code
L
Description
Relay Output
Input: 10...40V DC and 20...30V AC
Output: Relay
Code
Q4
064
Description
Sinking/Sourcing Output ➊
4-Pin QD
6 ft (1.8 m) Cabled
F
Input: 85...264V AC Output: Relay
124
12 ft (3.6 m) Cabled
244
N
P
Transistor Output
10...30V DC; NPN (Sinking) Output
10...30V DC; PNP (Sourcing) Output
24 ft (7.2 m) Cabled
Relay Output ➋
Code
Description
Blank
B
Y
No Guard
Black Guard
Yellow Guard
e
Kit Option ➌
Code
Description
Q5
5-Pin QD
Blank
No Kit
b
065
1.8m (6ft) Cabled
K1
24V AC/DC Relay Kit
Mounting Hole Size
125
245
3.6m (12ft) Cabled
7.2m (24ft) Cabled
K2
K3
120V AC Relay Kit
240V AC Relay Kit
Code
Description
2
3
22.5mm (0.88in)
30.5mm (1.20in)
➊ These devices are transistor outputs.
➋ These devices have separate N.O. and N.C. output relays with a shared common.
➌ Safety relays should be used in two-hand control applications. Kits not available for solid-state (transistor output) devices. Kits include two identical touch buttons and one
MSR125HP safety relay with removeable terminals.
11-3
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Accessories
Colour
Catalogue
Number
Yellow
800Z-G3AG1
Black
800Z-G3AG2
Mounting Ring Nut for 22.5mm holes.
Used on 22.5mm devices.
Plastic
800Z-G2AH1
Mounting Ring Nut for 30.5mm holes.
Used on 30.5mm devices.
Plastic
800Z-G3AH1
57mm (2.25in)
Extension
60-2681
29mm (1.15in)
Extension
60-2439
Shiny Metal
800E-AHA1
Black Metal
800E-AHA2
Description
These guards prevent accidental activation of the touch
button surface and protect it from damage. Can be used for
both the 22.5mm and 30.5mm mounting products.
Guards
Plastic Mounting Kit
Plastic Mounting Kit
30.5mm Swivel/Tilt Mounting Assembly
This bracket allows you to orient the touch button in any
position. It can be mounted on any vertical or horizontal
surface. Compatible with 30.5mm mounting only.
Swivel Assembly
30.5mm to 22.5mm Hole Size Adaptor
This adaptor allows a 22.5mm push button operator to be
installed in a panel with existing 30.5mm mounting holes.
Adaptor
11-4
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Approximate Dimensions—mm (inches)
40.9
(1.61)
48.3
(1.90)
69.9 (2.75)
22mm
Version
Micro Quick
Disconnect
35.1
(1.38)
40.9
(1.61)
30mm
Version
Mini Quick
Disconnect
56.9
(2.24)
129.3 (5.09)
110.3
(4.34)
40.9
(1.61)
22mm
Version
39.4
(1.55)
22.4
(0.88)
Cable
129.3 (5.09)
General Purpose with Guards
40.9
(1.61)
30mm
Version
22.4
(0.88)
Cable
General Purpose
Typical Wiring Diagram
Electrical Connections: 10...40V DC and 20...30V AC Input Voltage (Relay Output); 85...264V AC Input Voltage (Relay Output)
Note: Separate N.O. and N.C. output relays with shared common.
Black (N.O.)
White (N.C.)
Gray (Common)
Brown (+) L1
Blue (-) L2
5 Conductor Cabled (Relay Output) for 800Z-GL_ _ _
Electrical Connections: 10...30V DC Input Voltage (Transistor Output); 150mA max. per circuit output
(+)
(+)
(-)
(-)
Brown (+) Blue (-)
Black (N.O.) Load
White (N.C.)
Load
Brown (+) Blue (-)
Load Black (N.O.)
White (N.C.)
Load
4 Conductor Cabled Sinking (NPN)
4 Conductor Cabled Sourcing (NPN)
Applications Details
LED Blink Rate
** ** **
*** *** ***
Diagnostic
Power Up
Noise Detection
**** **** ****
Margin Detection
Description
Device touched during power-up. Device will resume 10 seconds after removal of hand.
Device detected an unacceptable level of noise (>20V/m). Device will resume once noise
subsides.
A conductive film is building up on the sensing surface. Device will resume once cleared.