MEMORY HiCORDER 8870-20 Recorders Palm-size but Powerful Easy recording anytime, anywhere! Hioki's traditional MEMORY HiCORDER functions are now condensed into a lowprofile, turn-key device. The compact design includes a beautiful wide-screen QVGA-TFT LCD. Easy to use, with great functionality and performance, you will want to keep this extraordinarily compact MEMORY HiCORDER close to hand. ■ Compact and easy to carry ■ Easy, intuitive operation ■ Simple PC connection ■ Fast, 1MS/second performance despite the compact size ■ Built-in, compact-yet-sharp QVGA-TFT wide LCD 2 High performance instrument that fits in your hand Ultra compact, yet easy to use Actual Size The “Settings Navigator” function guides operations Activate the Settings Navigator Real-Time waveform monitoring When powered on, the Settings screen appears along with The help text crawls along the bottom of the screen, the waveform monitor, and the new Settings Navigator blinks. describing the function of the setting at the blinking cursor. By activating the Settings Navigator, you can easily navigate The enhanced “Waveform Monitor” window with level meter by following the simple instructions. Soon you will be display facilitates changes to settings by simultaneously operating the device like a seasoned professional. displaying real-time input waveforms. 3 Acquire and store data on a CompactFlash card for analysis on a personal computer Simple, intuitive operation Easy connection to a PC The 8870-20 feels like a hand-held tester, yet takes waveform Connect to a PC with the supplied USB cable to easily download snapshots. It has no complicated functions - allowing you to data that has been automatically saved to a CF card. Use the observe waveforms quickly and increasing your work efficiency. supplied dedicated application program to display and print ■ Easily make settings while viewing levels on the Settings screen. waveforms on the PC. ■ Observe waveforms ■ Easy USB 2.0 data transfer using only simple ■ Dedicated application program for memory recorder displaying and printing waveforms functions. Note: The CF card installed in the HiCORDER appears as a removable disk on the PC, but communication functions such as the capability to change HiCORDER settings from the PC are not available. Isolated inputs for safe measurements Compact, easy-to-carry design Isolated analog channel inputs provide CAT II overvoltage protection Volume and weight have both been reduced by 60% from HIOKI's safety for measurements of up to 300 V AC and DC (maximum previously most compact MEMORY HiCORDER, the 8807-01, to terminal-to-ground rating). This capability just 40% the volume and 55% the weight. Easily pack it in your e n a b l e s s a f e s i m u l t a n e o u s vo l t a g e briefcase to accompany you wherever measurements of inverter primary and you go. secondar y and stacked bat ter y cells ■ Only 176 mm wide, 101 mm high without damaging the instrument. and 41 mm thick ■ 300 V isolation between measurement terminals and HiCORDER chassis Floating Voltage ■ 300 V isolation between measurement ■ Weighs only 600 g even with the battery pack installed terminals Waveform display and printing, and CSV conversion with PC Either off-line, or via USB 2.0, easily copy data to a PC. Open a data file with the dedicated Wave Processor (PC application program) for the 8870-20, to import and print waveforms with your Data is simply saved to a CF card. When own arrow and figure annotations. Of course, screen data the HiCORDER is connected to a PC can be copied and pasted into common Word and Excel via USB 2.0, the data is quickly copied documents to easily from the installed card to the PC: 20,000 create reports. waveform screen divisions transfer in about 20 seconds. 4 Portable size for on-site jobs Catering to a multitude of applications Sequential control fault analysis CB timing measurements Momentary supply dropouts and low AC voltage are often found to Analyze the relationships of multi-point logic signals and analog be causes of abnormal interruptions and warnings from sequentially waveforms to detect timing issues that can affect power supply controlled devices in factory production and testing lines. For optimal circuit breakers. Use logic probes to record relay operations on up operational analysis, specify to four channels, or use Differential Probe an abnormal power event as 9322 for 440-volt power measurements a trigger and simultaneously and for support of CAT III and CAT IV record waveforms of associated sequential relay signals, AC power and DC voltage systems. overvoltage measurement categories. When facility troubles require waveforms right away! Battery operation is especially convenient in those situations where no power outlet is available. Just plug in the supplied AC adapter to recharge the battery, regardless of whether the HiCORDER is on or off. The battery pack is automatically quick charged (autorecharging function) whenever its capacity is depleted. A full charge provides about two hours of operation. Synchronize two HiCORDERs together for four-channel recording! For those times when t wo channels are just not enough, synchronize two 8870-20's using the external trigger I/O terminals (apply the trigger output from one to the external trigger input of the other). Then use synchronous start to automatically record four channels of measurement data to a CF card. 5 Have you ever had an experience like these? “ T he r e's a p r oble m w it h t he fa ci l it y, s o you ne e d t o s e e wavefor m s w it hout f u l l me a s u r e me nt i n s t r u me nt at ion…” “ You of t e n h ave t o v i sit wor k sit e s t o s e t u p pla nt s a nd fa ci l it ie s , but t y pic a l me a s u r e me nt i n s t r u me nt s a r e t o o bu l k y…” Unattended monitoring for unpredictably intermittent leakage phenomena Record instantaneous waveforms of leakage current and line voltage. Use “Out-of-Window” triggering to detect leakage events only when the input is outside of specified upper and lower limits. Measurement data is saved to CF card whenever leakage phenomena occur. Later, reload the data into the 8 870 - 2 0 a n d u s e t h e cursor functions to analyze Fa s t , 1MS/s e c ond p e r for m a nc e d e s pit e it s c om p a c t si z e. I s olat e d i n put s e n s u r e s a fe c om me r cia l p owe r me a s u r e me nt s. Wavefor m d e t a i l s c a n b e e a si ly ob s e r ve d . Record motor inrush current waveforms Reliably record waveforms of motor startup current. Measure current signals preferably using the 9018-10 Clamp-On Probe, or with the 3283 CLAMP ON LEAK HiTESTER. Models 3284 and 3285 C L A M P O N AC/ D C HiTESTERs are also ideal for DC waveform measurements. peak current values or breaker tripping events. Confirm inverter output waveforms In the automobile servicing industry Inverter performance analysis requires simultaneous observation of Analyze phenomena in ways that are just not possible with dedicated the high frequency carrier signal and the low frequency fundamental fault diagnostic instruments. The high-speed sampling capability of the waveform being switched. The combination of high-speed sampling 8870-20 as a compact hand-held oscilloscope capability and high-capacity memory make these observations provides mobility in situations that call for possible. For current delicate testing, such as when performing waveform observations, high-level analysis or measuring specifiable use HIOKI clamp sensors phenomena. capable of high-frequency measurements without direct electrical contact. Capture momentary commercial power outages Long-period recording like a pen recorder Easily monitor the instantaneous waveform of 50/60 Hz commercial Record dual-level DC voltage systems as you would with a pen power. Use triggering to rec ord recorder. Use the 10 ms sampling rate to record momentary voltage unexpected waveform anomalies. fluctuations.The internal two-Megaword memory offers about five Capture momentary commercial power hours of recording with a 10 ms sampling interval. outages and voltage dips. 6 ■ Main unit Specifications (Accuracy at 23 ±5°C/73 ±9°F, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) Basic specifications No. of channels 2 analog and 4 logic channels (standard configuration, logic grounds are common with instrument ground) Measurement MEM (high-speed recording) functions Fastest sampling 1 MS/s (1 ms, all channels simultaneously) rate Memory capacity 12 bits × 2 MWords/ch Removable storage CF card Type I slot (standard equipment) × 1: Up to 1 GB (Flash ATA), supports FAT16 and FAT32 formats Clock and settings: 5 years or more (@25°C 77°F) Waveform backup function: available when BATTERY Backup function PACK 9780 is installed with charge remaining or AC adapter is connected (up to 100 hours with fully charged battery pack). USB: 1 port USB 2.0 High Speed mini-B receptacle, transfers files from the installed CF card to a PC when connected (mass storage External interface class device) Note: The CF card installed in the HiCORDER appears as a removable disk on the PC, but communication functions such as the capability to change HiCORDER settings from the PC are not provided. External control terminals Display type Display resolution Terminal block: External trigger input, trigger output 4.3-inch WQVGA-TFT color LCD (480 × 272 dots) Waveform section: 20 × 10 divisions (time axis × voltage axis), each division is 20 × 20 dots Temperature and humidity range for use: Environmental conditions 0°C (32°F) to 40°C (104°F), 80% rh or less (no condensation) Temperature and humidity range for storage: -10°C (14°F) to 50°C (122°F), 80% rh or less Compliance standard Power requirements Safety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3 AC ADAPTER 9786: 100 to 240 V AC (50/60 Hz) BATTERY PACK 9780: About 2h continuous operation (AC adapter has priority when both are used) 12 V DC supply: 10 to 16 V (cable available by special order) The installed battery pack charges when the AC adapter is connected. Charging functions Charging time is about 200 minutes at 25°C (77°F). Memory recorder functions 100 μs to 5 min/div, 20 ranges, time axis resolution 100 points/div, time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to 1/1,000 in 9 stages, Auto roll mode display at 50 ms/div or slowely range Time axis Sampling speed 1/100th of time axis range, (1 µs period maximum, simultaneous Recording length Ten settings from 20 to 20,000 div, or continuous Pre-trigger Screen types Split screen (none, only 1 screen), X-Y screen (none, but possible at use with the supplied PC software), Waveform or numerical logging (switched), Voltage axis zoom (×2 to ×10), compression (×1/2 to ×1/5) Instantaneous value or RMS value display (only DC and 50/60 Hz) Reflesh rate: 0.5 sec, Sampling speed: 10 kS/sec, 4 digits: (the lowest Numerical display Saving function Setting configurations, measurement data (binary and text), screen data (compressed bitmap format), numerical calculation results, thinned data saving (text) Cursor readout Trace, vertical and horizontal Scaling function Selectable by model (clamp or Differential Probe 9322), specified conversion ratio (output ratio, division ratio), 2-point setting method Comment entry Title comments can be entered for each channel (including logic) Screen capture Gauges 30 VA max. (charging with the AC adapter) 10 VA max. (charging with a 12 V supply) Dimensions and mass Approx. 176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D, 600 g (21.2 oz) (with the BATTERY PACK 9780 installed) Preserve starting conditions Supplied accessories Instruction Manual × 1, Measurement Guide × 1, AC ADAPTER 9786 × 1, Strap × 1, USB cable × 1, Application Disk (dedicated program for the 8870-20) × 1, PROTECTION SHEET 9809 × 1 Trigger sources Trigger types (analog) Level setting Logic Trigger Two analog and four logic channels, external trigger (falls below 2.5 V, or shorted terminals), ON/OFF switching of each source, AND/OR between sources, manual triggering Level trigger: Triggering occurs when the signal rises or falls through a specified voltage level. Window trigger: Triggering occurs when the signal level rises above or falls below specified upper and lower limits. Voltage drop trigger: Intended particularly for 50/60 Hz commercial power, triggering occurs when the peak voltage is below the specified value. Resolution : 0.5% of full scale (full scale = 10 divisions) 1, 0, ×, or specified pattern Other functions Analog Input (Accuracy at 23 ±5°C/73 ±9°F, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) Measurement functions Input connectors Measurement range Measurement resolution low with at least 1 ms pulse width) Number of channels: 2, for voltage measurement Isolated BNC connector (input impedance 1 MΩ, input capacitance 7 pF) Max. rated voltage to earth: 300 V AC, DC, CAT II (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) 10 mV to 50 V/div, 12 ranges, full scale: 10 div, AC voltage for possible measurement/display using voltage axis × 1/2: 280 Vrms, Low-pass filter: 5 Hz/50 Hz/500 Hz/5 kHz 1/100 of measurement range (using 12-bit A/D conversion, measurement range is ±10 times per-division range value) Highest sampling rate 1 MS/s (simultaneous sampling in 2 channels) Accuracy DC amplitude: ±0.5 % of full scale (after zero-adjust, f.s. = 10 div of per-division measurement range) Frequency characteristics DC to 50kHz -3dB Input coupling The displayed screen is saved to CF card as a compressed bitmap Vertical axis gauges can be displayed for two channels on the waveform screen If power fails while measuring, measurement can be automatically resumed when power is restored Included Auto save To jump to a specific waveform location Scroll bar Waveform monitor Logic signal view Setting is possible while monitoring waveforms on the Settings screen In 4-bit units, four selectable display positions Single or continuous Set by the number of samples, from 0 to 100, in five steps Pre-trigger recording to capture waveforms before and after triggering, trigger output (terminal block, 5-volt open-collector active Trigger filter digit displays as 0 for values 0 to 4, and 5 for values 5 to 9) Voltage axis range: 10 mV, 50 mV, 100 mV, 500 mV, 1 V, 5 V, 10 V, 50 V/div, auto ranging, Accuracy : ±2.5 % of reading ±5 digits Up to four simultaneous calculations (common to all channels), calculation results are saved to CF card, Calculation contents: average, peak, maximum and minimum Numerical calculation values, RMS, period and frequency Calculation range: specified by A/B cursors or whole recording length Power consumption Trigger modes (limited by timebase, only the last 20,000 div are saved) Records waveforms prior to trigger events, from 0 to 100% of the specified recording length Notes: Charging time depends on battery condition. Charging is disabled to protect the battery at ambient temperatures out of 5°C (41°F) to 30°C (86°F). Trigger functions sampling in all channels) DC/GND Max. allowable input 400 V DC (the maximum voltage that can be applied across input pins without damage) n Maximum Recording Time for the Memory Function • Because data is not recorded directly to the CF card, maximum recording time is independent of CF card capacity. Maximum recording time is determined only by internal memory capacity. • Operation cannot be guaranteed when recording continuously for more than one year (with a slow timebase). • Maximum recording length is the same whether using one or two channels. Time axis Sampling period 2M-Word (=4MB) 20,000 div Max. 100 μs/div 1 μs 2s 500 μs/div 5 μs 10 s 200 μs/div 2 μs 1 ms/div 10 μs 5 ms/div 50 μs 2 ms/div 10 ms/div 20 ms/div 20 μs 100 μs 200 μs 4s 20 s 40 s 1 min 40 s 3 min 20 s 6 min 40 s 50 ms/div 500 μs 16 min 40 s 200 ms/div 2 ms 1 h 06 min 40 s 1 s/div 10 ms 5 h 33 min 20 s 5 s/div 50 ms 100 ms/div 500 ms/div 2 s/div 1 ms 5 ms 20 ms 33 min 20 s 2 h 46 min 40 s 11 h 06 min 40 s 1 d 03 h 46 min 40 s 10 s/div 100 ms 1 min/div 600 ms 13 d 21 h 20 min 00 s 3.0 s 69 d 10 h 40 min 00 s 30 s/div 2 min/div 5 min/div 300 ms 1.2 s 2 d 07 h 33 min 20 s 6 d 22 h 40 min 00 s 27 d 18 h 40 min 00 s 7 n Features of the Dedicated Wave Processor Program (supplied accessory) l Designed especially for MEMORY HiCORDER 8870-20 Application program displays and prints waveforms, and converts measurement l Multiple files can be batch-converted to CSV data data to CSV text files on a Windows PC. l Provides X-Y display capability not available on the HiCORDER l Generate reports using templates, with figure annotations and entered comments Wave Processor Program for the 8870 -20 Supported measurement MEMORY HiCORDER 8870-20 only instruments Operating environment PC running Windows 2000, XP, or Vista (32-bit versions) File loading Loadable data format: Memory function data (MEM extension) Max. loadable file size: The maximum size that can be stored by the 8870-20 (subject to the capacity of the PC’s operating environment) Overwriting save Overwrites saved scaling and title/channel comments Displaying Slideshow display Sequentially displays waveform files in the same folder Text conversion Data conversion format: Select from CSV, tab-separated or spaceseparated Object data range: Whole range, or between cursors Data thinning: Available by specifying interval Conversion methods: Analog waveform data to voltage values, logic data is converted to ones and zeros Conversion channels: selectable Header contents: Title, trigger date, timebase, comments, per-channel setting conditions Batch conversion: specify multiple files for batch conversion Printing Display language: English or Japanese (select during installation) Waveform display: Scroll and magnify/reduce the time axis of the displayed waveform data image, move the zero position of each channel, zoom and set the vertical axis of each channel independently (variable gain) Numerical value display: included Cursor functions: Manipulate A and B cursors independently, and display time and voltage numerically. Max. displayable channels: two analog and four logic channels Gauge display: Time gauge (absolute or relative time, seconds, data points), voltage gauge (for each channel) Figure annotations: Text boxes, straight lines, arrows, circles and rectangles at any location Screen capture: Extended meta format, bitmap format Search functions: Date, maximum, minimum, level and window search Template function: Save and reload waveform file display configurations Printer support: Color and monochrome printing on printers supported by the operating system Printable ranges: All data, screen capture and specifiable areas Print formats: Undivided, two divisions, 2, 4, 8 or 16 traces, single XY screen, gauges, channel comments, zero-position comments, and A/ B cursor values Print preview and waveform screen hard copy/logging print functions are included ■Options specifications (sold separately) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) Note: The unit-side plug of the 9320-01 is different from the 9320. LOGIC PROBE 9320 -01 Function Input (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year) Detection of voltage signal or relay contact signal for High/Low state recording 4 channels (common ground between unit and channels), digital/ contact input, switchable (contact input can detect open-collector signals), input impedance: 1 MΩ (with digital input, 0 to +5 V), 500 kΩ or more (with digital input, +5 to +50 V), pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V) Digital input threshold 1.4 V/2.5 V/4.0 V 1.5 kΩ or higher (open) and 500 Ω or lower (short), 3.5 kΩ or Contact input higher (open) and 1.5 kΩ or lower (short), 25 kΩ or higher (open) detection resistance and 8 kΩ or lower (short) Response speed Max. allowable input DIFFERENTIAL PROBE 9322 Function DC mode AC mode RMS mode 500 ns or lower 0 to +50 V DC (the maximum voltage that can be applied across input pins without damage) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) Note: The unit-side plug of the 9321-01 is different from the 9321. LOGIC PROBE 9321-01 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year) Function Detection of AC or DC relay drive signal for High/Low state recording. Can also be used for power line interruption detection Input 4 channels (isolated between unit and channels), HIGH/LOW range switching, Input impedance: 100 kΩ or higher (HIGH range), 30 kΩ or higher (LOW range) Output (H) detection 170 to 250 V AC, ±DC (70 to 250 V ) (HIGH range) 60 to 150 V AC, ±DC (20 to 150 V) (LOW range) 0 to 30 V AC, ±DC (0 to 43 V) (HIGH range) 0 to 10 V AC, ±DC (0 to 15 V) (LOW range) Rising edge 1 ms max., falling edge 3 ms max. (with HIGH range Response time at 200 V DC, LOW range at 100 V DC) Maximum allowable 250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum voltage that can be applied across input pins without damage) input voltage Output (L) detection Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.3 oz) Input Maximum allowable input (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) For high-voltage floating measurement, power line surge noise detection, RMS rectified output measurement For waveform monitor output, frequency characteristics: DC to 10 MHz (±3 dB), amplitude accuracy: ±1 % of full scale (at max. 1000 V DC), ±3 % of full scale (at max. 2000 V DC) (full scale: 2000 V DC) For detection of power line surge noise, frequency characteristics: 1 kHz to 10 MHz ±3 dB DC/AC voltage RMS output detection, frequency characteristics: DC, 40 Hz to 100 kHz, response speed: 200 ms or less (400 V AC), accuracy: ±1 % of full scale (DC, 40 Hz to 1 kHz), ±4 % of full scale (1 kHz to 100 kHz) (full scale: 1000 V AC) Input type: balanced differential input, input impedance/ capacitance: H-L 9 MΩ/10 pF, H/L-unit 4.5 MΩ/20 pF, Max. rated voltage to earth: when using grabber clip 1500 V AC/DC (CAT II ), 600 V AC/DC (CAT III), when using alligator clip: 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III) 2000 V DC, 1000 V AC (CAT II), 600 V AC/DC (CAT III) Output Voltage divider for 1/1000 of input, BNC connectors (output switchable for 3 modes DC, AC, RMS) Power source Connect the AC ADAPTER 9418-15, (power cannot be supplied from the logic terminals of the 8870-20) 8 Supplied AC Adapter Options for Voltage measurement (Not supplied. Purchase together with attachment clips appropriate for your application.) ALLIGATOR CLIP 9790-01 Red/black set attaches to the ends of test leads (9790) GRABBER CLIP 9790-02 Red/black set attaches to the ends of test leads (9790) CONNECTION CORD 9790 (Thin Type) CAT II 300V, ultraflexible 2.8 mm (0.11 in) diameter test lead cable, 1.5 m (4.92 ft) length Note: Attachment clips sold separately. Battery Pack CONTACT PIN 9790-03 Red/black set attaches to the ends of test leads (9790) Tip Expanders 9790-03 Tip Expanders 9790-01 Tip Expanders Attachment clips are sold separately from CONNECTION CORD 9790. Purchase the appropriate attachment clips for your application separately Charges while installed in the HiCORDER BATTERY PACK 9780 NiMH, Charges while installed Tip Expanders 9790-02 Voltage measurement (Requiring power for probe) Removable storage Supplied with PC Card adapter PC CARD 128M 9726 (128MB capacity) DIFFERENTIAL PROBE 9322 2 kV DC for input up to 1 kV AC, CAT III-600 V and CAT II-1000 V maximum terminal-to-ground rating PC Card Precaution U s e o n l y P C C a rd s s o l d by HIOKI. Compatibility a n d p e r f o r m a n c e a re n o t guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards. AC ADAPTER 9418-15 For powering Differential probe 9322, 100 to 240 V AC, 12 V/2.5 A PC CARD 256M 9727 (256MB capacity) PC CARD 512M 9728 (512MB capacity) PC CARD 1G 9729 (1GB capacity) Case Voltage measurement MEMORY HiCORDER 8870-20 (English model, instrument only) Note: Test leads are not included. Purchase the leads appropriate for your application separately. AC Adapter 9786 is the only supplied accessory. CONNECTION CORD 9198 CAT II-300 V, 5-mm (0.20 in) dia. cable, 1.5 m (4.92 ft) length CONNECTION CORD 9197 SOFT CASE 9812 Includes space for small items, Neoprene rubber CAT II-500 V, 5-mm (0.20 in) dia. cable, 1.5 m (4.92 ft) length Logic signal measurement (One probe can be installed to provide four channels) Supplied Accessories Case CONVERSION CABLE 9323 LOGIC PROBE 9320-01 4-channel type, for voltage/contact signal ON/OFF detection (miniature terminal type) LOGIC PROBE 9321-01 Used for connecting the 9320/9321 and 8870 series MEMORY HiCORDERs, because the terminal shapes are different. 4 isolated channels, ON/OFF detection of AC/DC voltage * This cable is not required for the smallterminal (miniature terminal type) types 9320-01 and 9321-01. Current measurement Not CE marked CLAMP ON LEAK HiTESTER 3283 10 mA to 200 A AC For LCD protection, pairs of additional sheets can be purchased separately. 10 A to 500 A Clamp tester connection requires OUTPUT CORD 9094 and Conversion Adapter 9199. CLAMP ON AC/DC HiTESTER 3284 CLAMP ON AC/DC HiTESTER 3285 AC ADAPTER 200 A to 2000 A AC/DC 9445-02/-03 20 A to 1000 A for the 3283/3284/3285, 9V/1A HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] Includes compartment for options, Resin coated 100 to 240 V AC 20 A to 200 A AC/DC CLAMP ON PROBE CLAMP ON PROBE 9018-50 9132-10 CARRYING CASE 9782 PROTECTION SHEET 9809 AC ADAPTER 9786 Not CE marked OUTPUT CORD 9094 3.5-mm mini plug, and banana plugs, 1.5 m (4.92 ft) length CONVERSION ADAPTER 9199 Female banana terminals to BNC plug (output) DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of May 22, 2008. All specifications are subject to change without notice. 8870-20E1-85M-05P Printed in Japan