ASM-SENSOR 8870-20

MEMORY HiCORDER 8870-20
Recorders
Palm-size but Powerful
Easy recording anytime, anywhere!
Hioki's traditional MEMORY HiCORDER functions are now condensed into a lowprofile, turn-key device. The compact design includes a beautiful wide-screen
QVGA-TFT LCD. Easy to use, with great functionality and performance, you will
want to keep this extraordinarily compact MEMORY HiCORDER close to hand.
■ Compact and easy to carry
■ Easy, intuitive operation
■ Simple PC connection
■ Fast, 1MS/second performance despite the compact size
■ Built-in, compact-yet-sharp QVGA-TFT wide LCD
2
High performance instrument that fits in your hand
Ultra compact, yet easy to use
Actual Size
The “Settings Navigator” function guides
operations
Activate the Settings Navigator
Real-Time waveform monitoring
When powered on, the Settings screen appears along with
The help text crawls along the bottom of the screen,
the waveform monitor, and the new Settings Navigator blinks.
describing the function of the setting at the blinking cursor.
By activating the Settings Navigator, you can easily navigate
The enhanced “Waveform Monitor” window with level meter
by following the simple instructions. Soon you will be
display facilitates changes to settings by simultaneously
operating the device like a seasoned professional.
displaying real-time input waveforms.
3
Acquire and store data on a CompactFlash card for analysis
on a personal computer
Simple, intuitive operation
Easy connection to a PC
The 8870-20 feels like a hand-held tester, yet takes waveform
Connect to a PC with the supplied USB cable to easily download
snapshots. It has no complicated functions - allowing you to
data that has been automatically saved to a CF card. Use the
observe waveforms quickly and increasing your work efficiency.
supplied dedicated application program to display and print
■ Easily make settings while viewing levels on the Settings screen.
waveforms on the PC.
■ Observe waveforms
■ Easy USB 2.0 data transfer
using only simple
■ Dedicated application program for
memory recorder
displaying and printing waveforms
functions.
Note: The CF card installed in the HiCORDER appears as a
removable disk on the PC, but communication functions such as
the capability to change HiCORDER settings from the PC are not
available.
Isolated inputs for safe measurements
Compact, easy-to-carry design
Isolated analog channel inputs provide CAT II overvoltage protection
Volume and weight have both been reduced by 60% from HIOKI's
safety for measurements of up to 300 V AC and DC (maximum
previously most compact MEMORY HiCORDER, the 8807-01, to
terminal-to-ground rating). This capability
just 40% the volume and 55% the weight. Easily pack it in your
e n a b l e s s a f e s i m u l t a n e o u s vo l t a g e
briefcase to accompany you wherever
measurements of inverter primary and
you go.
secondar y and stacked bat ter y cells
■ Only 176 mm wide, 101 mm high
without damaging the instrument.
and 41 mm thick
■ 300 V isolation between measurement
terminals and HiCORDER chassis
Floating Voltage
■ 300 V isolation between measurement
■ Weighs only 600 g even with the
battery pack installed
terminals
Waveform display and printing, and CSV conversion with PC
Either off-line, or via USB 2.0, easily copy data to a PC.
Open a data file with the dedicated Wave Processor (PC application program)
for the 8870-20, to import and print waveforms with your
Data is simply saved to a CF card. When
own arrow and figure annotations. Of course, screen data
the HiCORDER is connected to a PC
can be copied and pasted into common Word and Excel
via USB 2.0, the data is quickly copied
documents to easily
from the installed card to the PC: 20,000
create reports.
waveform screen divisions transfer in about
20 seconds.
4
Portable size for on-site jobs
Catering to a multitude of applications
Sequential control fault analysis
CB timing measurements
Momentary supply dropouts and low AC voltage are often found to
Analyze the relationships of multi-point logic signals and analog
be causes of abnormal interruptions and warnings from sequentially
waveforms to detect timing issues that can affect power supply
controlled devices in factory production and testing lines. For optimal
circuit breakers. Use logic probes to record relay operations on up
operational analysis, specify
to four channels, or use Differential Probe
an abnormal power event as
9322 for 440-volt power measurements
a trigger and simultaneously
and for support of CAT III and CAT IV
record waveforms of associated
sequential relay signals, AC
power and DC voltage systems.
overvoltage measurement
categories.
When facility troubles require waveforms right away!
Battery operation is especially convenient in those situations where
no power outlet is available. Just plug in the supplied AC adapter
to recharge the battery, regardless of whether the HiCORDER is
on or off. The battery pack is automatically quick charged (autorecharging function) whenever its capacity is depleted. A full
charge provides about two hours of operation.
Synchronize two HiCORDERs together for four-channel recording!
For those times when t wo channels are just not enough,
synchronize two 8870-20's using the external trigger I/O terminals
(apply the trigger output from one to the external trigger input of
the other). Then use synchronous start
to automatically record four channels of
measurement data to a CF card.
5
Have you ever had an experience like these?
“ T he r e's a p r oble m w it h t he fa ci l it y,
s o you ne e d t o s e e wavefor m s w it hout f u l l
me a s u r e me nt i n s t r u me nt at ion…”
“ You of t e n h ave t o v i sit wor k sit e s t o s e t u p
pla nt s a nd fa ci l it ie s , but t y pic a l me a s u r e me nt
i n s t r u me nt s a r e t o o bu l k y…”
Unattended monitoring for unpredictably
intermittent leakage phenomena
Record instantaneous waveforms of leakage current and line voltage.
Use “Out-of-Window” triggering to detect leakage events only when
the input is outside of specified upper and lower limits. Measurement
data is saved to CF card whenever leakage phenomena occur. Later,
reload the data into the
8 870 - 2 0 a n d u s e t h e
cursor functions to analyze
Fa s t , 1MS/s e c ond p e r for m a nc e d e s pit e it s
c om p a c t si z e.
I s olat e d i n put s e n s u r e s a fe c om me r cia l p owe r
me a s u r e me nt s. Wavefor m d e t a i l s c a n b e e a si ly
ob s e r ve d .
Record motor inrush current waveforms
Reliably record waveforms of motor startup current. Measure current
signals preferably using the 9018-10 Clamp-On Probe, or with
the 3283 CLAMP ON LEAK HiTESTER. Models 3284 and 3285
C L A M P O N AC/ D C
HiTESTERs are also
ideal for DC waveform
measurements.
peak current values or
breaker tripping events.
Confirm inverter output waveforms
In the automobile servicing industry
Inverter performance analysis requires simultaneous observation of
Analyze phenomena in ways that are just not possible with dedicated
the high frequency carrier signal and the low frequency fundamental
fault diagnostic instruments. The high-speed sampling capability of the
waveform being switched. The combination of high-speed sampling
8870-20 as a compact hand-held oscilloscope
capability and high-capacity memory make these observations
provides mobility in situations that call for
possible. For current
delicate testing, such as when performing
waveform observations,
high-level analysis or measuring specifiable
use HIOKI clamp sensors
phenomena.
capable of high-frequency
measurements without direct electrical contact.
Capture momentary commercial power outages
Long-period recording like a pen recorder
Easily monitor the instantaneous waveform of 50/60 Hz commercial
Record dual-level DC voltage systems as you would with a pen
power. Use triggering to rec ord
recorder. Use the 10 ms sampling rate to record momentary voltage
unexpected waveform anomalies.
fluctuations.The internal two-Megaword memory offers about five
Capture momentary commercial power
hours of recording with a 10 ms sampling interval.
outages and voltage dips.
6
■ Main unit Specifications
(Accuracy at 23 ±5°C/73 ±9°F, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year)
Basic specifications
No. of channels
2 analog and 4 logic channels (standard configuration, logic grounds
are common with instrument ground)
Measurement
MEM (high-speed recording)
functions
Fastest sampling
1 MS/s (1 ms, all channels simultaneously)
rate
Memory capacity 12 bits × 2 MWords/ch
Removable
storage
CF card Type I slot (standard equipment) × 1: Up to 1 GB (Flash
ATA), supports FAT16 and FAT32 formats
Clock and settings: 5 years or more (@25°C 77°F)
Waveform backup function: available when BATTERY
Backup function
PACK 9780 is installed with charge remaining or AC adapter
is connected (up to 100 hours with fully charged battery pack).
USB: 1 port USB 2.0 High Speed mini-B receptacle, transfers files
from the installed CF card to a PC when connected (mass storage
External interface class device)
Note: The CF card installed in the HiCORDER appears as a removable disk on the PC, but
communication functions such as the capability to change HiCORDER settings from the PC
are not provided.
External control
terminals
Display type
Display resolution
Terminal block: External trigger input, trigger output
4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
Waveform section: 20 × 10 divisions (time axis × voltage axis),
each division is 20 × 20 dots
Temperature and humidity range for use:
Environmental conditions 0°C (32°F) to 40°C (104°F), 80% rh or less
(no condensation)
Temperature and humidity range for storage:
-10°C (14°F) to 50°C (122°F), 80% rh or less
Compliance
standard
Power
requirements
Safety: EN61010,
EMC: EN61326, EN61000-3-2, EN61000-3-3
AC ADAPTER 9786: 100 to 240 V AC (50/60 Hz)
BATTERY PACK 9780: About 2h continuous operation
(AC adapter has priority when both are used)
12 V DC supply: 10 to 16 V (cable available by special order)
The installed battery pack charges when the AC adapter is connected.
Charging functions Charging time is about 200 minutes at 25°C (77°F).
Memory recorder functions
100 μs to 5 min/div, 20 ranges, time axis resolution 100 points/div,
time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to 1/1,000
in 9 stages, Auto roll mode display at 50 ms/div or slowely range
Time axis
Sampling speed
1/100th of time axis range, (1 µs period maximum, simultaneous
Recording length
Ten settings from 20 to 20,000 div, or continuous
Pre-trigger
Screen types
Split screen (none, only 1 screen), X-Y screen (none, but possible
at use with the supplied PC software), Waveform or numerical
logging (switched),
Voltage axis zoom (×2 to ×10), compression (×1/2 to ×1/5)
Instantaneous value or RMS value display (only DC and 50/60 Hz)
Reflesh rate: 0.5 sec, Sampling speed: 10 kS/sec, 4 digits: (the lowest
Numerical display
Saving function
Setting configurations, measurement data (binary and text), screen
data (compressed bitmap format), numerical calculation results,
thinned data saving (text)
Cursor readout
Trace, vertical and horizontal
Scaling function
Selectable by model (clamp or Differential Probe 9322), specified
conversion ratio (output ratio, division ratio), 2-point setting
method
Comment entry
Title comments can be entered for each channel (including logic)
Screen capture
Gauges
30 VA max. (charging with the AC adapter)
10 VA max. (charging with a 12 V supply)
Dimensions and
mass
Approx. 176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D,
600 g (21.2 oz) (with the BATTERY PACK 9780 installed)
Preserve starting
conditions
Supplied
accessories
Instruction Manual × 1, Measurement Guide × 1, AC ADAPTER
9786 × 1, Strap × 1, USB cable × 1, Application Disk (dedicated
program for the 8870-20) × 1, PROTECTION SHEET 9809 × 1
Trigger sources
Trigger types
(analog)
Level setting
Logic Trigger
Two analog and four logic channels, external trigger (falls below
2.5 V, or shorted terminals),
ON/OFF switching of each source, AND/OR between sources,
manual triggering
Level trigger: Triggering occurs when the signal rises or falls
through a specified voltage level.
Window trigger: Triggering occurs when the signal level rises
above or falls below specified upper and lower limits.
Voltage drop trigger: Intended particularly for 50/60 Hz
commercial power, triggering occurs when the peak voltage is
below the specified value.
Resolution : 0.5% of full scale (full scale = 10 divisions)
1, 0, ×, or specified pattern
Other functions
Analog Input
(Accuracy at 23 ±5°C/73 ±9°F, 80 % rh or less, after 30 minutes of warm-up time; accuracy
guaranteed for 1 year)
Measurement functions
Input connectors
Measurement
range
Measurement resolution
low with at least 1 ms pulse width)
Number of channels: 2, for voltage measurement
Isolated BNC connector (input impedance 1 MΩ, input capacitance 7 pF)
Max. rated voltage to earth: 300 V AC, DC, CAT II (with input
isolated from the unit, the maximum voltage that can be applied between input
channel and chassis and between input channels without damage)
10 mV to 50 V/div, 12 ranges, full scale: 10 div, AC voltage for
possible measurement/display using voltage axis × 1/2: 280 Vrms,
Low-pass filter: 5 Hz/50 Hz/500 Hz/5 kHz
1/100 of measurement range (using 12-bit A/D conversion, measurement range is ±10 times per-division range value)
Highest sampling rate 1 MS/s (simultaneous sampling in 2 channels)
Accuracy
DC amplitude: ±0.5 % of full scale (after zero-adjust, f.s. = 10 div
of per-division measurement range)
Frequency characteristics DC to 50kHz -3dB
Input coupling
The displayed screen is saved to CF card as a compressed bitmap
Vertical axis gauges can be displayed for two channels on the
waveform screen
If power fails while measuring, measurement can be automatically
resumed when power is restored
Included
Auto save
To jump to a specific waveform location
Scroll bar
Waveform monitor
Logic signal view
Setting is possible while monitoring waveforms on the Settings
screen
In 4-bit units, four selectable display positions
Single or continuous
Set by the number of samples, from 0 to 100, in five steps
Pre-trigger recording to capture waveforms before and after
triggering, trigger output (terminal block, 5-volt open-collector active
Trigger filter
digit displays as 0 for values 0 to 4, and 5 for values 5 to 9)
Voltage axis range: 10 mV, 50 mV, 100 mV, 500 mV, 1 V, 5 V, 10 V,
50 V/div, auto ranging,
Accuracy : ±2.5 % of reading ±5 digits
Up to four simultaneous calculations (common to all channels),
calculation results are saved to CF card,
Calculation contents: average, peak, maximum and minimum
Numerical calculation
values, RMS, period and frequency
Calculation range: specified by A/B cursors or whole recording
length
Power
consumption
Trigger modes
(limited by timebase, only the last 20,000 div are saved)
Records waveforms prior to trigger events, from 0 to 100%
of the specified recording length
Notes: Charging time depends on battery condition. Charging is disabled to protect the battery at
ambient temperatures out of 5°C (41°F) to 30°C (86°F).
Trigger functions
sampling in all channels)
DC/GND
Max. allowable input 400 V DC (the maximum voltage that can be applied across input pins without damage)
n Maximum Recording Time for the Memory Function
• Because data is not recorded directly to the CF card, maximum recording time is independent of CF card capacity.
Maximum recording time is determined only by internal memory capacity.
• Operation cannot be guaranteed when recording continuously for more than one year (with a slow timebase).
• Maximum recording length is the same whether using one or two channels.
Time axis
Sampling period
2M-Word (=4MB)
20,000 div Max.
100 μs/div
1 μs
2s
500 μs/div
5 μs
10 s
200 μs/div
2 μs
1 ms/div
10 μs
5 ms/div
50 μs
2 ms/div
10 ms/div
20 ms/div
20 μs
100 μs
200 μs
4s
20 s
40 s
1 min 40 s
3 min 20 s
6 min 40 s
50 ms/div
500 μs
16 min 40 s
200 ms/div
2 ms
1 h 06 min 40 s
1 s/div
10 ms
5 h 33 min 20 s
5 s/div
50 ms
100 ms/div
500 ms/div
2 s/div
1 ms
5 ms
20 ms
33 min 20 s
2 h 46 min 40 s
11 h 06 min 40 s
1 d 03 h 46 min 40 s
10 s/div
100 ms
1 min/div
600 ms
13 d 21 h 20 min 00 s
3.0 s
69 d 10 h 40 min 00 s
30 s/div
2 min/div
5 min/div
300 ms
1.2 s
2 d 07 h 33 min 20 s
6 d 22 h 40 min 00 s
27 d 18 h 40 min 00 s
7
n Features of the Dedicated Wave Processor Program (supplied accessory)
l Designed especially for MEMORY HiCORDER 8870-20
Application program displays and prints waveforms, and converts measurement
l Multiple files can be batch-converted to CSV data
data to CSV text files on a
Windows PC.
l Provides X-Y display
capability not available on
the HiCORDER
l Generate reports using
templates, with figure
annotations and entered
comments
Wave Processor Program for the 8870 -20
Supported measurement
MEMORY HiCORDER 8870-20 only
instruments
Operating environment PC running Windows 2000, XP, or Vista (32-bit versions)
File loading
Loadable data format: Memory function data (MEM extension)
Max. loadable file size: The maximum size that can be stored by the
8870-20 (subject to the capacity of the PC’s operating environment)
Overwriting save
Overwrites saved scaling and title/channel comments
Displaying
Slideshow display Sequentially displays waveform files in the same folder
Text conversion
Data conversion format: Select from CSV, tab-separated or spaceseparated
Object data range: Whole range, or between cursors
Data thinning: Available by specifying interval
Conversion methods: Analog waveform data to voltage values, logic
data is converted to ones and zeros
Conversion channels: selectable
Header contents: Title, trigger date, timebase, comments, per-channel
setting conditions
Batch conversion: specify multiple files for batch conversion
Printing
Display language: English or Japanese (select during installation)
Waveform display: Scroll and magnify/reduce the time axis of
the displayed waveform data image, move the zero position of
each channel, zoom and set the vertical axis of each channel
independently (variable gain)
Numerical value display: included
Cursor functions: Manipulate A and B cursors independently, and
display time and voltage numerically.
Max. displayable channels: two analog and four logic channels
Gauge display: Time gauge (absolute or relative time, seconds, data
points), voltage gauge (for each channel)
Figure annotations: Text boxes, straight lines, arrows, circles and
rectangles at any location
Screen capture: Extended meta format, bitmap format
Search functions: Date, maximum, minimum, level and window search
Template function: Save and reload waveform file display
configurations
Printer support: Color and monochrome printing on printers supported
by the operating system
Printable ranges: All data, screen capture and specifiable areas
Print formats: Undivided, two divisions, 2, 4, 8 or 16 traces, single XY
screen, gauges, channel comments, zero-position comments, and A/
B cursor values
Print preview and waveform screen hard copy/logging print functions
are included
■Options specifications (sold separately)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm
(0.98 ft), approx. 150 g (5.3 oz)
Note: The unit-side plug of the 9320-01 is different from the 9320.
LOGIC PROBE 9320 -01
Function
Input
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy
guaranteed for 1 year)
Detection of voltage signal or relay contact signal for High/Low
state recording
4 channels (common ground between unit and channels), digital/
contact input, switchable (contact input can detect open-collector
signals), input impedance: 1 MΩ (with digital input, 0 to +5
V), 500 kΩ or more (with digital input, +5 to +50 V), pull-up
resistance: 2 kΩ (contact input: internally pulled up to +5 V)
Digital input threshold 1.4 V/2.5 V/4.0 V
1.5 kΩ or higher (open) and 500 Ω or lower (short), 3.5 kΩ or
Contact input
higher (open) and 1.5 kΩ or lower (short), 25 kΩ or higher (open)
detection resistance
and 8 kΩ or lower (short)
Response speed
Max. allowable input
DIFFERENTIAL PROBE 9322
Function
DC mode
AC mode
RMS mode
500 ns or lower
0 to +50 V DC (the maximum voltage that can be applied across
input pins without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft),
approx. 320 g (11.3 oz)
Note: The unit-side plug of the 9321-01 is different from the 9321.
LOGIC PROBE 9321-01
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy
guaranteed for 1 year)
Function
Detection of AC or DC relay drive signal for High/Low state
recording. Can also be used for power line interruption detection
Input
4 channels (isolated between unit and channels), HIGH/LOW
range switching, Input impedance: 100 kΩ or higher (HIGH
range), 30 kΩ or higher (LOW range)
Output (H)
detection
170 to 250 V AC, ±DC (70 to 250 V ) (HIGH range)
60 to 150 V AC, ±DC (20 to 150 V) (LOW range)
0 to 30 V AC, ±DC (0 to 43 V) (HIGH range)
0 to 10 V AC, ±DC (0 to 15 V) (LOW range)
Rising edge 1 ms max., falling edge 3 ms max. (with HIGH range
Response time
at 200 V DC, LOW range at 100 V DC)
Maximum allowable 250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum
voltage that can be applied across input pins without damage)
input voltage
Output (L)
detection
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm
(1.51 ft), approx. 350 g (12.3 oz)
Input
Maximum allowable
input
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30
minutes of warm-up time; accuracy guaranteed for 1 year)
For high-voltage floating measurement, power line surge noise
detection, RMS rectified output measurement
For waveform monitor output, frequency characteristics: DC to
10 MHz (±3 dB), amplitude accuracy: ±1 % of full scale (at max.
1000 V DC), ±3 % of full scale (at max. 2000 V DC) (full scale:
2000 V DC)
For detection of power line surge noise, frequency characteristics:
1 kHz to 10 MHz ±3 dB
DC/AC voltage RMS output detection, frequency characteristics:
DC, 40 Hz to 100 kHz, response speed: 200 ms or less (400 V
AC), accuracy: ±1 % of full scale (DC, 40 Hz to 1 kHz), ±4 % of
full scale (1 kHz to 100 kHz) (full scale: 1000 V AC)
Input type: balanced differential input, input impedance/
capacitance: H-L 9 MΩ/10 pF, H/L-unit 4.5 MΩ/20 pF, Max.
rated voltage to earth: when using grabber clip 1500 V AC/DC
(CAT II ), 600 V AC/DC (CAT III), when using alligator clip: 1000
V AC/DC (CAT II), 600 V AC/DC (CAT III)
2000 V DC, 1000 V AC (CAT II), 600 V AC/DC (CAT III)
Output
Voltage divider for 1/1000 of input, BNC connectors (output
switchable for 3 modes DC, AC, RMS)
Power source
Connect the AC ADAPTER 9418-15, (power cannot be supplied
from the logic terminals of the 8870-20)
8
Supplied AC Adapter
Options for Voltage measurement (Not supplied. Purchase together with attachment clips appropriate for your application.)
ALLIGATOR CLIP 9790-01
Red/black set attaches to the ends
of test leads (9790)
GRABBER CLIP 9790-02
Red/black set attaches to the ends
of test leads (9790)
CONNECTION CORD 9790
(Thin Type) CAT II 300V, ultraflexible 2.8 mm (0.11 in) diameter test
lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
Battery Pack
CONTACT PIN 9790-03
Red/black set attaches to the ends
of test leads (9790)
Tip Expanders
9790-03
Tip Expanders
9790-01
Tip Expanders
Attachment clips are sold separately
from CONNECTION CORD 9790.
Purchase the appropriate attachment
clips for your application separately
Charges while installed in
the HiCORDER
BATTERY PACK 9780
NiMH, Charges while installed
Tip Expanders
9790-02
Voltage measurement (Requiring power for probe)
Removable storage
Supplied with PC Card adapter
PC CARD 128M 9726
(128MB capacity)
DIFFERENTIAL PROBE 9322
2 kV DC for input up to 1 kV AC, CAT III-600 V and
CAT II-1000 V maximum terminal-to-ground rating
PC Card Precaution
U s e o n l y P C C a rd s s o l d
by HIOKI. Compatibility
a n d p e r f o r m a n c e a re n o t
guaranteed for PC cards made
by other manufacturers. You
may be unable to read from or
save data to such cards.
AC ADAPTER 9418-15
For powering Differential probe 9322,
100 to 240 V AC, 12 V/2.5 A
PC CARD 256M 9727
(256MB capacity)
PC CARD 512M 9728
(512MB capacity)
PC CARD 1G 9729
(1GB capacity)
Case
Voltage measurement
MEMORY HiCORDER 8870-20 (English model, instrument only)
Note: Test leads are not included. Purchase the leads appropriate for your application separately. AC
Adapter 9786 is the only supplied accessory.
CONNECTION
CORD 9198
CAT II-300 V, 5-mm (0.20 in)
dia. cable, 1.5 m (4.92 ft) length
CONNECTION
CORD 9197
SOFT CASE 9812
Includes space for small items, Neoprene
rubber
CAT II-500 V, 5-mm (0.20 in)
dia. cable, 1.5 m (4.92 ft) length
Logic signal measurement (One probe can be installed to provide four channels)
Supplied Accessories
Case
CONVERSION CABLE 9323
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal
ON/OFF detection
(miniature terminal type)
LOGIC PROBE 9321-01
Used for connecting the 9320/9321 and
8870 series MEMORY HiCORDERs,
because the terminal shapes are different.
4 isolated channels, ON/OFF detection
of AC/DC voltage
* This cable is not required for the smallterminal
(miniature terminal type)
types 9320-01 and 9321-01.
Current measurement
Not CE marked
CLAMP ON LEAK HiTESTER 3283
10 mA to 200 A AC
For LCD protection, pairs of additional
sheets can be purchased separately.
10 A to 500 A
Clamp tester connection requires
OUTPUT CORD 9094 and
Conversion Adapter 9199.
CLAMP ON AC/DC HiTESTER
3284
CLAMP ON AC/DC HiTESTER
3285
AC ADAPTER
200 A to 2000 A AC/DC
9445-02/-03
20 A to 1000 A
for the 3283/3284/3285, 9V/1A
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
Includes compartment for options, Resin
coated
100 to 240 V AC
20 A to 200 A AC/DC
CLAMP ON PROBE CLAMP ON PROBE
9018-50
9132-10
CARRYING CASE 9782
PROTECTION SHEET 9809 AC ADAPTER 9786
Not CE marked
OUTPUT CORD
9094
3.5-mm mini plug, and
banana plugs, 1.5 m (4.92 ft)
length
CONVERSION ADAPTER
9199
Female banana terminals to BNC plug
(output)
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room 303, Profit Plaza, No.76, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of May 22, 2008. All specifications are subject to change without notice.
8870-20E1-85M-05P
Printed in Japan