DIFFERENTIAL PROBE 9322

DIFFERENTIAL PROBE 9322
Recorders
Introducing a new 3-function universal probe
●Floatingmeasurementofhigh-voltagewaveforms
●Detectionofpowersupplysurgenoise
●RMSrectifiedoutput
MainApplications
Measurementofpotentialdifferencesincludedincommonmodevoltages,suchasIGBT
●Measurementofcommercialpowerlinewaveforms,suchason400Vpowerlines
●Measurementofhighvoltagesurgenoisewaveforms
●MeasurementoftheRMSvalueofinverteroutputs,etc.
2
­­❑ Product outline and features
3 kinds of measurement with a single probe
The DIFFERENTIAL PROBE 9322 provides
floating measurement of high voltage waveforms,
detection of surge noise on power supply lines, and
true RMS rectified output of high voltage AC.
Works with a variety of power supplies, such as
an AC adapter or logic terminal
For operation, convenience is the key. Operating
power for the DIFFERENTIAL PROBE 9322 can
be supplied from the standard logic terminals of a
MEMORY HiCORDER or the clamp sensor input
terminals of an F/V UNIT 8940, as well as from the
probe's own AC ADAPTER 9418-15.
Fl o a t i n g m e a s u r e m e n t of h i g h -vo l t a g e
waveforms (DC mode)
When measuring the potential difference in signals
containing a large common mode voltage component
on commercial power lines, an electrocution
hazard exists unless measurement is done using
an instrument with fully isolated inputs, such
as a MEMORY HiCORDER. When measuring
signals carrying common mode voltages with a
high frequency component (such as those produced
by inverter control circuits and switching power
supplies), measurements are greatly affected
by the rate of common mode elimination at the
isolated inputs. Although MEMORY HiCORDERs
provide the greatest possible to-ground voltage
rating (ordinarily 400V AC or DC), use of the
DIFFERENTIAL PROBE 9322 raises the rating
level to 1500V AC (CAT II), 600V AC (CAT III),
allowing measurement of circuits carrying even
larger common mode voltages. Potential differences
can be measured for input voltages of up to 2000V
DC or 1000V AC (CAT II), 600V AC/DC (CAT III), producing a 1/1000 divided output.
Measurement of power line surge noise (AC
mode)
Upon selecting the AC output mode, the AC coupled
signal inside the probe is divided by 1000 for output.
Since the probe's frequency range is from 1kHz to
10MHz, output waveforms are produced only when
input voltages contain high frequency components,
such as surge noise imposed on 50/60Hz commercial
mains power. The probe can thus serve as either a
noise detector or for measurement of wave peaks.
Provides output of true RMS rectified voltages
(RMS mode)
Upon selecting the RMS output mode, the input
signal is divided by 1000, rectified to obtain the
true RMS value, then output as a direct current
voltage. True RMS rectification is performed by an
analog circuit with a bandwidth of 40Hz to 100kHz,
allowing true RMS conversion of signals containing
high frequency components, such as inverter output
waveforms, as well as 50/60Hz commercial mains.
3-phase inverter output circuit
(Floating measurement is essential due to varying emitter potentials of each phase.)
3-phase inverter waveform recording example
3
Dimensions and mass: approx. 70 (2.76in) W × 150 (5.91in) H × 25 (0.98in) D mm,
approx. 350g (12.3oz)
Cable length: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft)
Basic specifications (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year)
DC mode
Measurement
functions
(1) DC mode, (2) AC mode, (3) RMS mode
Application
Waveform monitor output
Input type
Balanced differential input
Frequency
characteristic
DC to 10 MHz, ±3 dB
DC amplitude
accuracy
±1 % f.s. (1000 V DC or less)
±3 % f.s. (2000 V DC or less) f.s.=2000 V DC
Voltage division ratio 1/1000
H–L: 9 MΩ, approx 10 pF (C at 100 kHz)
H-case, L–case: 4.5 MΩ, approx 20 pF (C at 100 kHz)
BNC terminal (DC/AC/RMS 3-mode selectable output)
Input resistance,
capacity
Output
AC mode
Application
Max. allowable input 2000 V DC, 1000 V AC (CAT II ), 600 V AC/DC (CAT III )
When using grabber clip: 1500V AC/DC (CAT II), 600V AC/
Max. rated voltage to DC (CAT III)
earth
When using alligator clip: 1000V AC/DC (CAT II), 600V
AC/DC (CAT III)
10000:1 or better (input/output ratio at 50/60 Hz with input
shorted)
1000:1 or better (input/output ratio at 100 kHz or 1 MHz with
input shorted)
Common mode
elimination ratio
(1)AC ADAPTER 9418-15 (DC 12 V±10%)*1
(2)Power supply through POWER CORD 9324 connected to
logic connector on MEMORY HiCORDER.
(3)Power supply through POWER CORD 9325 connected to
sensor connector on F/V UNIT 8940.
(4)Power supply through POWER CORD 9328 connected
Power consumption to DC jack on Input UNIT 8950/ 8952/ 8953/ 8955, for the
MEMORY HiCORDER 8855.
(5)Power supply through POWER CORD 9248 connected
to the PROBE POWER UNIT 9687, for MEMORY
HiCORDER 8860-50/ 8861-50.
*1Operating voltage range: +5 to +12V, less than 300mA.
DC jack OD 5.5 mm, ID 2.1 mm
Detection of power line surge noise
Frequency response 1 kHz to 10 MHz ±3 dB
RMS mode
Application
Rectified RMS output of DC and AC voltages
Frequency response DC, 40 Hz to 1 kHz : ±1 % f.s.
Output accuracy
1 kHz to 100 kHz : ±4 % f.s. f.s.=1000 V AC
Response speed
200 ms or less (400 V AC )
Other
CE mark compliance Safety: EN61010, EMC: EN61326
Supplied
accessories
Grabber clips × 2, Alligator clips × 2, Carrying case × 1
How to power the 9322 with a HIOKI MEMORY HiCORDER
Input unit
8950,
8952,
F/V Unit 8940’s sensor terminal 8953-10,
8955's DC
jack
Logic Connector
Main unit Required Number of
power cord Maximum
(s)
connectable
9322s
Simultaneous use of
9320, 9321/-01 logic
probes
Required Number of
power cord Maximum
connectable
9322s
Max. Units
when 3273 or
9270 series are
also used
8826
9324
4
4 × 9322: No
3 × 9322: 4
2 × 9322: 6
1 × 9322: 7
9325
6
6
8835-01
9324
1
No
9325
4
4
8835 *1
9324
1
No
9325
4
4
8841 *1
9324
1
No
9325
6
4
8842 *1
9324
1
No
9325
6
4
9687
Probe
Power Unit
for 8860
series only
Use with the
power cord
9248
(1)Power supply from the AC ADAPTER (2)Power supply from logic probe terminal via
the POWER CORD 9324
9418-15
(3)Power supply from sensor connector on 8940
via the POWER CORD 9325
8847 *2
9324 &
9323
4 *2
4 × 9322: No
3 × 9322: 3
2 × 9322: 3
1 × 9322: 3
8855
9324 &
9323
2
2 × 9322: No
1 × 9322: 3
9324 &
8860-50
9323
2
2 × 9322: No
1 × 9322: 3
9325
6
8
8 *3
8860 *1
9324 &
9323
2
2 × 9322: No
1 × 9322: 3
9325
6
8
8 *3
8861-50
9324 &
9323
2
2 × 9322: No
1 × 9322: 3
9325
6
8
8 *3
8861 *1
9324 &
9323
2
2 × 9322: No
1 × 9322: 3
9325
6
8
8 *3
9328
*1 Discontinued
*2 Not including the channels available with the LOGIC UNIT 8973
*3 Depends on the combination of other probes in use; please consult with your HIOKI distributor
(4)P o w e r s u p p l y f r o m t h e M E M O RY
HiCORDER 8855 via the POWER CORD
9328
(5)Power supply from the MEMORY HiCORDER 8860-50/ 886150 via the POWER CORD 9248 and the PROBE POWER UNIT
9687
O rderin g in f o rm atio n
• The DIFFERENTIAL PROBE 9322 cannot be used by itself. Please use it in
combination with a HIOKI MEMORY HiCORDER.
• The DIFFERENTIAL PROBE 9322 requires a power supply.
DIFFERENTIAL PROBE 9322 (up to 2kV DC, 1kV AC)
Usable Input Units
● Usable HiCORDERs
MEMORY HiCORDER 8860-50/8861-50
(Input unit sold
8956, 8957, 8959, 8936, 8938
MEMORY HiCORDER 8860/8861 (Input unit sold separately)
MEMORY HiCORDER 8855 (Input unit sold separately)
MEMORY HiCORDER 8841/8842 (Input unit sold separately)
MEMORY HiCORDER 8835 -01 /8835 (Input unit sold
8956, 8957, 8959, 8936, 8938
8950, 8952, 8953-10, 8955
8936, 8938
MEMORY HiCORDER 8826 (Input unit sold separately)
8936, 8938
separately)
separately)
MEMORY HiCORDER 8807/8808
MEMORY HiCORDER 8807-50/8808-50
POWER HiCORDER 8714/8715
(Equipped with input section as standard)
(Equipped with input section as standard)
(Equipped with input section as standard)
8936, 8938
Option
POWER CORD 9324
POWER CORD 9248
Power supply from the PROBE
POWER UNIT 9687 for the
MEMORY HiCORDER 8860-50/
8861-50, 70 cm (2.30 ft) length
AC ADAPTER 9418-15
For powering Differential
probe 9322, 100 to 240 V
AC
Power supply from large
type logic connector,
50 cm (1.64 ft) length
POWER CORD 9325
PROBE POWER UNIT 9687
Factory-installed option - only use with the MEMORY
HiCORDER 8860-50/8861-50, built in on the bottom case.
Simultaneously power up to 8 units of Differential Probe 9322.
(Max. 3 A output)
Power supply from 8940
sensor connector, 30 cm
(0.98 ft) length
POWER CORD 9328
Power supply from 8950,
8952, 8953-10, 8955 input
units for the MEMORY
HiCORDER 8855,
15 cm (0.49 ft) length
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong
Road, Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room A-3206, Victory PlazaServices Center, No.103,
Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of May. 11, 2009. All specifications are subject to change without notice.
9322E5-95M-00P Printed in Japan