3639-20 PULSE LOGGER

2001
3639-20 PULSE LOGGER
LOGGER
Simple, economical pulse logging for a wide range of uses
Pulse Totalizer for Hygrometers, Flowmeters etc.
●Compact, light weight (130g) and easy to install
●High-capacity recording (up to 32,000 data points)
●Accumulates up to 9,999 counts
●Noise filtering to minimize the possibility of miscounts
●Data is protected during battery discharge and
replacement
●Recording interval selectable in 16 steps between
once/second and once/day
●Accepts a wide range of input voltages
●View recording data graphically or numerically on a PC
●Alarm output provided (with selectable threshold)
HIOKI Model 3639-20
■Cumulative Rainfall
Measurement
■Cumulative Flow Measurement
http://www.hioki.co.jp/
ISO14001
JQA-E-90091
HIOKI company overview, new products, environmental considerations and
other information are available on our website.
■Cumulative Power Data Collection
l(Watt-hour meter with pulse output terminal)
■ HIOKI 3639-20 PULSE LOGGER Measurement
Function Specifications
Input
Data Analysis and Processing on a PC
Data can be transferred to a PC using the HIOKI 3911
COMMUNICATION BASE. Up to 32,000 data points from
each of 8 channels can be collected and then transferred to the
PC for analysis and processing.
Pulse input: 1 channel
• No-voltage input connection (e.g., switch or relay) counts
when contact across terminals changes from short to open.
• Voltage input: +1.5 to 45V high, 0 to 0.2V low
(logic state is undetermined between 0.2 and 1.5V)
A count occurs when voltage level becomes high
3639 -20
3911
RS-232C Cable
Measurement accuracy ±1 dgt. or better
Clock precision
Measurement range
±100 ppm or better (±100 µs per second error) at 23 ±5˚C
Display: 9,999 counts/interval
"OF" is displayed for 10,000+ counts (internal data is also "OF")
Input filter
For mechanical contacts: Pulse width at least 20 ms with at
least 40 ms interval (max. 25 Hz)
For electrical connections: Max. 10 kHz
Display
Measured value (refreshed by setting recording interval),
Recording status (while recording or awaiting preset start
time), Recording interval (when set), Battery status (4-step
remaining battery charge meter), Preset start indicator,
Alarm setting
(Infrared transfer)
Settings that can be made from communications software:
current time, recording interval, recording method, comment entry,
recording mode, alarm
■ HIOKI 3911 COMMUNICATION BASE
Specification
Recording start
Manual, or at preset time
Communication
method
Up to 16,000 data points × 16 channels,
Up to 32,000 data points × 8 channels
Infrared between Leak Logger and 3911,
RS-232C serial between 3911 and PC
Recording end
Manual, or when memory full
Power
Four AAA size alkaline batteries (LR03 × 4)
Max. power
consumption
0.2VA
Size & weight
Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g
Supplied
accessories
Supported
operating systems
PC communications software, user's guide and
operating manual
Recording capacity
Recording data quantity 32,000 data points
Recording interval
1, 2, 5, 10, 15, 20, 30 seconds
1, 2, 5, 10, 15, 20, 30, 60 minutes, or 1 day
Recording methods
One-time recording: Stops when memory full,
Endless recording: Older data is overwritten when memory full
Settings
By panel buttons:
Recording interval, manual start/stop, measurement display
on/off
By PC software:
Current time, recording interval, recording start, recording
method, input filter switching, alarm enable/disable, alarm
threshold
Alarm output
Activated when input reaches a preset threshold count, (opendrain output: max. 200 mA at 30V DC, 200 mW dissipation)
Option
Supplied accessories
HIOKI 9629
CONNECTION CABLE
HIOKI 9632
CONNECTION CABLE
HIOKI 3911
COMMUNICATION BASE
Windows 9x, NT 4.0
■ HIOKI 3639-20 PULSE LOGGER General
Specifications
Backup
: Data backup is provided (data is
preserved when batteries are exhausted
or replaced)
Interface
: Serial infrared. Requires separate HIOKI
3911 COMMUNICATION BASE
Power
: Four 1.5V AAA size alkaline batteries
(LR03 × 4)
Battery life
: More than three months (measuring
enabled, display off, measurement
interval 10 minutes or more, non-voltage
input connection, at 23 ±5˚C
Max. power consumption
: 0.1VA
Dimensions
: Approx. 57.5(W) × 86.5(H) × 30(D) mm
(excluding projections)
Weight
: Approx. 130 g (including batteries)
Operating temp. & humidity : 0 to 50˚C, 80% RH max.
(non-condensating)
Supplied accessories
: HIOKI 9629 CONNECTION CABLE
(Measurement Input)
HIOKI 9632 CONNECTION CABLE
(Alarm Output)
AAA-size Alkaline Batteries (LR03 × 4),
User's Guide
Option
: HIOKI 3911 COMMUNICATION
BASE
■ Option
Model 3639-20 PULSE LOGGER
Model 3911 COMMUNICATION BASE
Model 9629 CONNECTION CABLE (supplied with 3639, 5 m)
Model 9632 CONNECTION CABLE (supplied with 3639, 1 m)
Model 9637 RS-232 CABLE (9-pin to 9-pin crossover, 1.8 m)
Model 9638 RS-232 CABLE (9-pin to 25-pin crossover, 1.8 m)
DISTRIBUTED BY
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@ hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
All information correct as of Apr. 5 2001. All specifications are subject to change without notice.
■ Inter net HIOKI website h t t p : / / w w w . h i o k i . c o . j p /
363920E2-14B-05P
Printed in Japan