ETC 2-1393223-1

Miniature Power Relay MSR
V23061
PCB relay for DC voltage,
neutral, monostable
Features
●
Used as a switching element for electrical separation
between low-power control circuits and power load
circuits
●
With 8 mm clearance and creepage distances up to 8 A
continuous current (UL, CSA: 10 A)
●
Low self-heating thanks to low power consumption
●
High packing densities possible
●
Suitable for fully automated processing
●
General-purpose relay for instrumentation and control
●
Mechanical and electrical characteristics comply with the
“Rules for electrical relays in power installations”
(VDE 0435/9.72)
●
Used for safe electrical insulation in the following applications
– power installations (VDE 0160)
– open and closed-loop control equipment for domestic
use (VDE 0631)
– electrical equipment for domestic use
(VDE 0700)
– electronic equipment for domestic use
(VDE 0860); on request
ECR0001-B
Approx. 1:1 scale
Design
–
Size I with 1 make contact
or
Size II with 1 changeover contact
–
For printed circuit assembling
–
Immersion cleanable or suitable for soldering lines
Approvals
Typical applications
VDE
●
Interface technology
●
Heating control systems
●
Temperature controllers
●
Timer switches
●
Household equipment
2
VDE
Mark of conformity
SEV
89.1 02176.02
CSA
File LR 45064-7
UL
File E 48393
SEMKO
9049293
SETI
142344-01
3919
Siemens AG
Miniature Power Relay MSR
Dimensional drawing (in mm)
Size II
Size I
with 1 changeover contact
with 1 make contact
Mounting hole layout
View on the terminals
1 changeover contact
1 make contact
Terminal assignment
View on the terminals
1 changeover contact
Siemens AG
1 make contact
3
Miniature Power Relay MSR
Contact data
Contact category III according to VDE 0435 Part 120/10.81, Appendix B
Ordering code, block 3
A301/A302
Number of contacts and type
A401/A402
Single contacts
AgSnO2
AgCdO
AgNi 0,15
gold-flashed
Max. continuous current at
max. ambient temperature
AgCdO
gold-plated
8A
Inrush current
(max. 4 s at 10% duty cycle)
15 A
Maximum switching voltage
440 V~
300 V–
Maximum switching capacity
AC voltage
DC voltage
Recommended for loads >
A601/A602
1 changeover contact or 1 make contact
Contact assembly
Contact material
A501/A502
2000 VA
See load limit curve
500 mA, 12 V~/V–
Contact resistance
(initial value)/measuring
≤ 100 mΩ/1 A/24 V
current/driver voltage
Note: Inrush currents up to 80 A possible on request.
500 mA, 12 V~
≤ 100 mΩ/1 A/24 V
1 mA, 6 V–
µW
≤ 100 mΩ/100 mA/6 V ≤ 30 mΩ/100 mA/6 V
Load limit curve
I = switching current
U = switching voltage
Definition of the load limit curve:
In 1000 operations there must be no arc with a burning time > 10 ms.
4
Siemens AG
Miniature Power Relay MSR
Coil data
Nominal voltages
From 3 V– to 60 V–
Special voltages on request
Nominal power consumption, typ., at 20 °C
210 ... 270 mW
Pull-in power, at 20 °C
100 ... 120 mW
Operating range/class of energizing voltage according to DIN IEC 255
Part 1-00 or VDE 0435 Part 201
Minimum release voltage
2/b
10 % of nominal voltage
Coil versions
Nominal voltage
Unom
V–
Operate voltage
at 20 °C
Uop cold
V–
Operating voltage range
at 20 °C
Oper. voltage UI
V–
Max. voltage UII
V–
Resistance
at 20 °C
Number of coil,
ordering code,
block 2
Ω
3
2.1
2.1
7.5
40 ±
4
001
5
3.4
3.6
12.5
118 ±
12
002
6
4.1
4.3
15.0
165 ±
17
003
9
6.1
6.4
22.0
365 ±
37
004
12
8.2
8.5
30.0
650 ±
65
005
18
12.2
12.8
45.0
1455 ±
145
006
24
16.3
17.2
56.0
2270 ±
230
007
36
24.5
25.4
88.0
5640 ±
565
008
48
32.6
34.5
110.0
8790 ±
880
009
42.8
142.0
15265 ±
2290
010
60
40.8
Other coil versions available on request
Uop cold= Operate voltage at 20 °C without pre-energizing
the coil
UI
UII
= Operate voltage at 20 °C after pre-energizing with
Unom without contact current
kI
= Maximum continuous voltage at 20 °C for
Tc max = 115 °C without contact load
Operating voltage limits UI and UII depend on temperature and
can be calculated by:
UI tamb = kI · UI 20 °C and UII ta = kII · UII 20 °C
tamb =
UI tamb =
UII tamb=
kI a. kII =
Tc max =
Ambient temperature
Minimum voltage at ambient temperature tamb
Maximum voltage at ambient temperature tamb
Factors (dependent on temperature), see diagram
Maximum coil temperature
kII
Ambient temperature tamb
Siemens AG
5
Miniature Power Relay MSR
General data
Operate time at Unom and 20 °C, typ.
6 ms
Release time without/with parallel diode, typ.
2.5 ms / 10 ms
Bounce time, make/break contact typ.
0.5 ms / 4 ms
Maximum switching rate without load
1200 min-1
30 min-1
Maximum switching rate with rated load
Ambient temperature range according to
DIN IEC 255 Part 1-00 or VDE 0435 Part 201
-40 °C ... 70 °C
Thermal resistance
75 K/W
Coil temp. rise due to rated contact current
Approx. 7 K
Maximum permissible coil temperature
115 °C
Protection class according to
DIN 40050/IEC 529
Immersion cleanable IP 67
Suitable for soldering lines IP 50
Electrical endurance
Load
Contact
material
Contact
Endurance, typ.,
operations
Rated load 8 A, 230 V~
AgCdO
Make
1 x 105
Motor load 230 V~
Inrush current 18 A cosϕ 0.5
Rated current 1.8 A cosϕ 0.5
AgCdO
Make
4 x 105
AC15 3A according to
VDE 660 / IEC 947, 230 V~
AgSnO2
Make
2 x 105
Valve load 0.1 A, 230 V~
AgCdO
Make
1 x 106
Hydraulic valves 2 A, 24 V–
AgNi 0,15
Make
1 x 10 6
Lamp load 6 A, 230 V~
AgSnO2
Make
1 x 104
Approx. 1 x 107 operations
Mechanical endurance
Flammability according to UL 94
V-0
Solder bath temperature/max. duration
260 °C / 5 s
Mounting position
Processing information
Any
Wherever possible, ultrasonic cleaning should not be used; if absolutely necessary, then only after consultation with the manufacturer.
Weight
11 g
Insulation
According to IEC 664/VDE 110 (1/89):
rated voltage
pollution severity
overvoltage category
250 V
3
III
According to VDE 0110 (2/79):
insulation group/rated voltage
C/250
B/380
Dielectric test voltage, contact – coil (1 min)
Surge voltage, contact – coil (1.2 – 50 µs)
Dielectric test voltage between open contacts (1 min)
Clearance/creepage distances
Insulation resistance at 500 V (initial value)
Tracking resistance of the fundamental frame according to DIN IEC 112
6
4000 V~rms
8000 V
1000 V~rms
8 mm / 8 mm
> 105 MΩ
CTI 250
Siemens AG
Miniature Power Relay MSR
Ordering code
Block 1
Data position
1
2
3
4
5
Block 2
6
V 2 3 0 6 1
7
8
9 10 11
Block 3
12 13 14 15
A
Identifier for
Miniature Power Relay MSR
Size
A = Size I, with 1 make contact
B = Size II, with 1 changeover contact
Version
1 = immersion cleanable
2 = suitable for soldering lines
Coil number
001 = 3 V– nominal voltage
002 = 5 V–
003 = 6 V–
004 = 9 V–
005 = 12 V–
006 = 18 V–
007 = 24 V–
008 = 36 V–
009 = 48 V–
010 = 60 V–
Contact pile-up
A = Standard
Contact material
3 = AgSnO2
4 = AgCdO
5 = AgNi 0,15, gold-flashed
6 = AgCdO, hard gold-plated
Contact arrangement
01 = 1 changeover contact
02 = 1 make contact
Ordering example: V23061-B1005-A401
MSR relay with 1 changeover contact (Size II), coil 12 V nominal voltage,
contact material silver cadmium oxide (AgCdO)
Siemens AG