MPD A1511RU

A1500RU Series
4:1 Input Range, 15W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 15W Output Power
• 4:1 Input Voltage Range
• Compact DIP Case
• 1,600 VDC I/O Isolation
• Meets EN 55022 “A”
• Single & Dual Outputs
• 37.5 W/IN3 Power Density
• Industry Standard Pin-Out
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Input
Parameter
Conditions
Input Voltage Range
Input Filter
Input Reflected Ripple Current
Output
Parameter
Output Voltage Accuracy
Line Regulation, VIN = Min to Max
Load Regulation, IOUT = 0% to 100%
Cross Regulation, Dual Output
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit Protection
General
Parameter
Isolation Voltage (Input/Output)
Isolation Voltage (Case/Input, Output)
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT, See Note 4
Surge, See Note 4
CS
PFMF
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
24 VDC Input 9.0
24.0
36.0
48 VDC Input 18.0
48.0
75.0
␲ (Pi) Filter (Meets EN 55022 Class “A”)
20.0
Conditions
Min.
Typ.
±1.0
Single Output
Dual Output
Single Output
Dual Output
See Note 1
See Note 2
Max.
±0.2
±0.5
±0.5
±1.0
±5.0
60
150
250
25% Load Step Change
±3.0
±0.02
Continuous (Autorecovery)
Conditions
3 Seconds
3 Seconds
500 VDC
100 kHz/1V
Min.
1,600
1,600
1,000
Typ.
2,000
330
Standard
mA P - P
Units
%
%
%
%
mV P - P
% IOUT
µSec
%
%/ºC
Units
M⍀
pF
kHz
Level
Class A
Class A
Criteria B
Criteria A
Criteria B
Criteria B
Criteria A
Criteria A
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Ambient
Case
VDC
VDC
250
Conditions
Max.
Units
Min.
-40
Typ.
-40
Free Air Convection
RH, Non-condensing
95
Max.
+85
+105
+125
Units
ºC
ºC
ºC
%
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Metal with Non-Conductive Base (UL94V-0)
0.705 Oz (20g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
410
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
Units
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Voltage (VDC)
Current (mA)
Nominal
Range
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
A1501RU
A1502RU
A1503RU
A1504RU
A1505RU
A1506RU
A1507RU
A1511RU
A1512RU
A1513RU
A1514RU
A1515RU
A1516RU
A1517RU
Full-Load No-Load
647
732
710
710
744
718
710
327
370
355
359
372
359
355
10
10
10
10
10
10
10
5
5
5
5
5
5
5
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.1
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.1
12.0
15.0
±5.0
±12.0
±15.0
4,000
3,000
1,250
1,000
±1,500
±625
±500
4,000
3,000
1,250
1,000
±1,500
±625
±500
Notes:
1. When measuring cross regulation, the load on one output is varied from 25% to 100%
while the other output is held at 100%.
2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each
output to common for dual output units. For noise sensitive applications, the use of 3.3 µF
capacitors will reduce the output ripple.
3. Transient recovery is measured to within a 1% error band for a load step change of 75%
to 50% to 25%.
4. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, an external filter capacitor is required. It is recommended that a 680 µF/100V (or two 330 µF/100V capacitors
connected in parallel) be used.
5. Operation at no-load will not damage these units. However, they may not meet all specifications.
6. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do
this, connect the load across the positive (+VOUT) and negative (-VOUT) outputs and float
the output common.
7. It is recommended that a fuse be used on the input of a power supply for protection. See
the table above for the correct rating.
Min
Supply On
Supply Off
Standby Input Current
Control Common
3.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
(VDC)
3.9
6.2
15.0
18.0
±6.2
±15.0
±18.0
3.9
6.2
15.0
18.0
±6.2
±15.0
±18.0
(µF Max)
4,700
3,300
600
400
±1,500
±288
±200
4,700
3,300
600
400
±1,500
±288
±200
87
89
90
90
86
89
90
86
88
90
89
86
89
90
3,000
3,000
3,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
1,500
1,500
1,500
Derating Curve
Mechanical Dimensions
Remote ON/OFF
Parameter
Over
Max
Rating
Voltage Capacitive Efficiency Fuse
Slow-Blow
Protection
Load
(%, Typ)
(mA)
Max
Units
VDC
VDC
12 or Open
1.2
5 mA Typical
Referenced to Neg. Input (pin 2,3)
Pin Connections
Pin
Single
1
Remote On/Off
2
-VIN
3
-VIN
9
No Pin
11
NC
14
+VOUT
16
-VOUT
22
+VIN
23
+VIN
NC: No Connection
Dual
Remote On/Off
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]