July 13, 2004 www.firelite.com ACM-8RF DF-51555 B-500 Relay Module for use with MS-9200, -9200UD -9600 and MS -5210UD MS-9200UD -9200UD,, MS MS-9600 MS-5210UD MS Section: Annunciators GENERAL The ACM-8RF is a relay module in the FireLite AFM Series of annunciators. It provides the MS-9200, MS-9200UD and MS-9600 Fire Alarm Control Panels and MS-5210UD 10-zone Fire Alarm Control/Communicator with relay-byzone capability for elevator recall, HVAC control, etc. The ACM-8RF provides eight (8) Form-C mappable relays with contacts rated at 5 amps. The ACM-8RF mounts remote from the MS-9200, MS-9200UD, MS-9600 and MS-5210UD in an ABS-8RF enclosure. MEA 122-96-E, Vol. II S624 CS68/CS702 California State Fire Marshal 7120-0075:178 Up to 32 ACM-8RF relay modules may be installed on the panels EIA-485 circuit. FEATURES Provides eight Form-C relays with 5-amp contacts. Up to 32 ACM-8RFs may be installed on the MS-9200, MS-9200UD, MS-9600 and MS-5210UDs EIA-485 serial output. Mounts remotely in ABS-8RF enclosure. Requires only two wires for communication and two for power. Removable terminal blocks for ease of installation and service. DIP switch selectable memory mapping of relays. MOUNTING The ACM-8RF will only mount to an ABS-8RF annunciator surface-mount backbox with blank faceplate. OPERATION Communication between the Control Panel and the ACM8RF is accomplished over a two-wire EIA-485 serial interface. This communication, to include the wiring, is supervised by the fire alarm control panel. Power for the relay module is provided via a separate power loop from the control panel which is inherently supervised (loss of power also results in a communication failure at the control panel). RELAY MAPPING The ACM-8RFs relays follow the status of the 56 software zones of the MS-9200, the 99 software zones of the MS9200UD and MS-9600 or the 10 Initiating Device Circuits (IDCs) of the MS-5210UD. For full relay-by-zone capability with the MS-9200 (i.e., 56 software zones), a minimum of seven ACM-8RFs are required (alarm only). For full RelayBy-Zone capability with MS-9200UD and MS-9600, a minimum of 13 ACM-8RFs are required(alarm only). For full MS-5210UD relay-by-zone capability (i.e., all 10 zones), a minimum of two ACM-8RFs are required (alarm only). Consult the ACM-8RF installation manual for applicationspecific details. FireLite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact FireLite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. ACM-8RF Made in the U.S.A. DF-51555 07/13/04 Page 1 of 2 RELAY TERMINAL ASSIGNMENTS The ACM-8RF provides eight relays with Form-C contacts rated for 5 amps. The terminal assignments are illustrated below. Alarm Relay 4 Alarm Relay 3 Alarm Relay 2 Alarm Relay 1 { { { { Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open Common Normally Closed Relay 5 } Alarm OR Trouble Relay 1 Relay 6 } Alarm OR Trouble Relay 2 Relay 7 } Alarm OR Trouble Relay 3 Relay 8 } Alarm OR Trouble Relay 4 Circuits can be annunciated as alarm, or alarm and trouble. Alarm and trouble consumes two relays per zone. PRODUCT LINE INFORMATION ACM-8RF Relay module, 8 Form-C relays @ 5 amps. ABS-8RF Annunciator surface-mount backbox with blank faceplate. LED-10IM Remote annunciator interface module for MS5210UD (required for EIA-485 output). Supports up to 32 devices. ABS-8RF 9.94" H x 4.63" W x 2.50" D Page 2 of 2 DF-51555 07/13/04