AIMTEC AM15C

Series AM15C-Z
15Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
•
•
•
•
•
Ultra compact footprint 1”x1”
Wide Input Range2:1
1600 VDC Isolation
Remote ON/OFF Function
No Minimum Load Required
Adjustable Output Voltage
Operating Temperature -40ºC to +85ºC
Over Current and Over Voltage Protection
Efficiency up to 89%
RoHS Compliant
Models
Single output
Model
AM15C-1203SZ
AM15C-1205SZ
AM15C-1212SZ
AM15C-1215SZ
AM15C-2403SZ
AM15C-2405SZ
AM15C-2412SZ
AM15C-2415SZ
AM15C-4803SZ
AM15C-4805SZ
AM15C-4812SZ
AM15C-4815SZ
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
4
3
1.3
1
4
3
1.3
1
4
3
1.3
1
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
84
86
85
87
86
87
88
89
84
86
87
88
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
Models
Dual output
Model
AM15C-1205DZ
9-18
±5
±1.5
1600
85
AM15C-1212DZ
9-18
±12
±0.625
1600
87
AM15C-1215DZ
9-18
±15
±0.5
1600
88
AM15C-2405DZ
18-36
±5
±1.5
1600
85
AM15C-2412DZ
18-36
±12
±0.625
1600
88
AM15C-2415DZ
18-36
±15
±0.5
1600
89
AM15C-4805DZ
36-75
±5
±1.5
1600
84
AM15C-4812DZ
36-75
±12
±0.625
1600
87
AM15C-4815DZ
36-75
±15
±0.5
1600
88
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Nominal
Typical
12
24
48
9-18
18-36
36-75
www.aimtec.com
F 051e R11
Units
VDC
π
Nominal Vin with constant resistive load
12 Vin
24 Vin
48 Vin
Peak Input Voltage time
On/Off control
Maximum
20
ms
36
50
100
100
VDC
ms
ON –3 to 12VDC (or open)
OFF – 0 to 1.2VDC or short pin 2 to pin 3; OFF idle current – 5mA
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15C-Z
15Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Nominal
Typical
No load current
Under voltage lockout
12 Vin ON/OFF
24 Vin ON/OFF
48 Vin ON/OFF
Maximum
Units
15
mA
8.5 /7
17/15
34/35
20
Input reflected ripple current
VDC
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage
Case to Input
Case to Output
Resistance
Capacitance
Conditions
Typical
3 sec
3 sec
3 sec
1600
1600
1600
>1000
Maximum
Units
1200
VDC
VDC
VDC
MOhm
pF
Maximum
Units
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
25% load on one output - 100% load
on second load
Zener Diode Clamp
Full Load
HL-LL
0% to 100% load
0% to 100% balanced load
20MHz Bandwidth
Trim - Single output models only
±1
%
±5
%
120
170
Continuous
Auto-Recovery
±0.2
±0.5
±1
±0.02
100
±10
%
%
%
%
%
%/oC
mV p-p
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
www.aimtec.com
F 051e R11
Conditions
Typical
100% load
With derating above +65°C
-40 to +125
Maximum
375
-40 to +85
105
2.6
Free air convection
95
Nickel-coated copper
18
1.00 x 1.00 x 0.40 inches
25.40 x 25.40 x 10.16 mm
> 560,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec
260
Load step change 75% to 50% to 25%
250
Load step change 75% to 50% to 25%
±3
Tel: +1 514 620 2722
2 of 4
Units
KHz
o
C
o
C
o
C
%/ oC
% RH
g
o
C
µS
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15C-Z
15Watt | DC-DC Converter
Safety Specifications
Parameters
Agency Approvals
Standards
CE
EN 55022 Class A
EN 61000-4-2 Perf. Criteria A
EN 61000-4-3 Perf. Criteria A
EN 61000-4-4 Perf. Criteria A (external 220uF/100V cap required)
EN 61000-4-5 Perf. Criteria A (external 220uF/100V cap required)
EN 61000-4-6 Perf. Criteria A
EN 61000-4-8 Perf. Criteria A
NOTE: also designed to meet IEC 60950-1:2001
Test Circuits
Notes
1. Input filter (C1, C2, L) are needed to meet conducted emission (EN 55022 Class A) and should be mounted as close as possible to the
converter.
L 12uH
+
-
C1
2.2uF/100V
C2
2.2uF/100V
+V input
+V output
DC/DC
Converter
- V input
Load
-V output
Pin Out Specifications
Pin
1
2
3
4
5
6
Single
+ V input
- V input
On/Off Control
+ V output
Trim
- V output
www.aimtec.com
F 051e R11
Dual
+ V input
- V input
On/Off Control
+ V output
Common
- V output
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM15C-Z
15Watt | DC-DC Converter
Dimensions
Trimming
Bottom View
25.40
(1.00)
10.16 2.54
(0.40) (0.10)
10.16
(0.40)
5
4
6
20.32
(0.80)
25.40
(1.00)
+V Output Trim -V Output
+V
-V
Input Input CTRL
2
2.54
(0.10)
1
Side View
10.16
(0.40)
2.54 2.54
(0.10) (0.10)
2.54
(0.10)
Top View
3
5.08 7.62
(0.20) (0.30)
9.90
(0.39)
Printed Face
2.54
(0.10)
1.00
(0.39)
Derating
Free Air Convection
65 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80 85 100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 051e R11
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only